Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 75: 102-108, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33910047

RESUMO

The Area Deprivation Index (ADI) has been shown to be a determinant of healthcare outcomes in both medical and surgical fields, and is a measure of the socioeconomic status of patients. We sought to analyze outcomes in patients with upper extremity vascular injuries that were admitted over a five-year period to a Level I trauma center sorted by ADI. All patients with upper extremity vascular injury presenting to a level one trauma center between January 2013 and January 2017 were retrospectively collected. The patients were divided into two groups based on their ADI with the first group representing the lowest quartile of patients and the second group the higher three quartiles. Patient's demographics were analyzed as well as modes of trauma, hospital transfer status prior to receiving care, type of intervention received, follow-up rates and outcomes including both complication and amputation rates. Over this time period, a total of 88 patients with traumatic upper extremity vascular injuries were identified. The majority of injuries were due to penetrating trauma (74/88, 84%) with 41% (10/24) of patients in the lower ADI being victims of gunshot wounds compared to 27% (17/64) of those in the higher ADI (P = 0.19). Patients in the lowest ADI quartile were more likely to be African Americans (P= 0.0001), and more likely to be transferred to our university hospital prior to receiving care (P= 0.007). Arrival Glasgow Coma Scale and Injury Severity Score were similar as was time spent in the emergency room. Length of stay trended longer in the lowest ADI quartile as compared to the higher ADI (7.5 vs. 11.8, P= 0.59). The rates of long term follow-up were significantly lower in patients with the lowest ADI scores as opposed to the higher ADI group (P= 0.0098), however, there was no statistically significant difference in outcomes between the two groups including both complication and amputation rates. The ADI is associated with lower rates of long term follow-up after upper extremity vascular injuries, despite patients in both the high and low ADI groups having similar outcomes in regards to complication and amputation rates. Further study is warranted to investigate the role of the socioeconomic status in outcomes following traumatic injury.


Assuntos
Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde , Classe Social , Privação Social , Determinantes Sociais da Saúde , Extremidade Superior/irrigação sanguínea , Lesões do Sistema Vascular/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Bases de Dados Factuais , Feminino , Humanos , Estilo de Vida , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico , Lesões do Sistema Vascular/epidemiologia , Adulto Jovem
2.
J Vasc Access ; 21(6): 983-989, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32372676

RESUMO

OBJECTIVE: To translate the assessment item sets of the Canadian version of the quality of life assessment, venous device-port for breast cancer patients with chest and arm ports (i.e. different implanting sites) into Chinese version, and to conduct a test of reliability and validity for it. METHODS: According to the Brislin translation model, quality of life assessment, venous device-port underwent literal and back translations, and the Chinese version of quality of life assessment, venous device-port was preliminarily revised by consulting an expert and a preliminary test. A total of 270 cancer patients undergoing chemotherapy were assessed during the use of ports, and the reliability and the validity of the Chinese version of quality of life assessment, venous device-port scale were then tested. RESULTS: The scale consisted of 23 yes/no items and seven numerical rating scales. The total Cronbach's α coefficient of the scale was 0.829, and each item ranged from 0.812 to 0.845. The item-level content validity index was 0.67-1.00, and the scale-level content validity index/average and the scale-level content validity index/universal agreement were 0.98 and 0.90, respectively. The correlation coefficient of the repeated measurement results of the scale was 0.554 (p < 0.01). Exploratory factor analysis showed that the cumulative explained variance of five common factors was 64.197%. CONCLUSION: The Chinese version of quality of life assessment, venous device-port scale is an effective assessment tool for quality of life with good reliability and validity in breast cancer patients with different implantation sites for totally implanted venous access devices in northern China.


Assuntos
Antineoplásicos/administração & dosagem , Neoplasias da Mama/tratamento farmacológico , Cateterismo Periférico/instrumentação , Qualidade de Vida , Inquéritos e Questionários , Tórax/irrigação sanguínea , Tradução , Extremidade Superior/irrigação sanguínea , Dispositivos de Acesso Vascular , Administração Intravenosa , Adulto , Idoso , Neoplasias da Mama/diagnóstico , Neoplasias da Mama Masculina/diagnóstico , Neoplasias da Mama Masculina/tratamento farmacológico , Cateterismo Periférico/efeitos adversos , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Resultado do Tratamento
3.
J Vasc Access ; 21(6): 917-922, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32228229

RESUMO

INTRODUCTION: Peripherally inserted central catheters are very common devices for short, medium and long-term therapies. Their performance is strictly dependent on the correct tip location, at the junction between the upper caval vein and the right atrium. It is very important to obtain an estimated measure of the catheter, in order to reach the cavo-atrial junction and optimize the catheter length. Estimated measures are often obtained using cutaneous landmarks. OBJECTIVE: Evaluate the reliability of cutaneous landmark-based length estimation during catheter insertion. Identify any patient's related factors that may affect cutaneous landmarks reliability. METHODS: We used two distinct techniques and collected data about cutaneous landmark-based length estimation, electrocardiographic guided intravascular length, age, weight and height. We studied the reliability of possible correcting factors, balancing the error average by regression models, and we found and tested two different models of prediction. RESULTS: A total number of 519 patients were studied. The average bias, between the two studied length assessment by cutaneous landmarks and electrocardiographic guided catheter length, were 3.77 ± 2.44 cm and 3.28 ± 2.57 cm, respectively. The analysed prediction models (deviance explained 43.5%, Akaike information criterion = 1313.67% and 43.4%, Akaike information criterion = 1313.92), fitted on the validation set, showed a root mean square error of 3.07 and 3.06. CONCLUSION: Landmark-based length estimation for preventive catheter length assessment seems to be unreliable, when associated with post-procedural tip location. They are useful for distal trimming catheters to optimize the 'out of skin' portion when associated with electrocardiographic tip location. Models identified for balancing bias are probably not useful.


Assuntos
Pontos de Referência Anatômicos , Cateterismo Venoso Central/instrumentação , Cateterismo Periférico/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Extremidade Superior/irrigação sanguínea , Idoso , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Eletrocardiografia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
J Vasc Surg ; 71(3): 913-919, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31327606

RESUMO

OBJECTIVE: Infectious complications of arteriovenous grafts (AVGs) are a major source of morbidity. Our aim was to characterize contemporary risk factors for upper extremity AVG infection. METHODS: The Vascular Quality Initiative (2011-2018) was queried for all patients undergoing upper extremity AVG creation. AVG infection was classified as an infection treated with antibiotics, incision and drainage, or graft removal. Multivariable analyses were used to evaluate risk factors for short- and long-term AVG infection. RESULTS: Of 1758 upper extremity AVGs, 49 (2.8%) developed significant infection within 3 months, resulting in incision and drainage in 24% and graft removal in 76% of cases. None were managed with antibiotics alone in the study sample. Patients with significant AVG infection were more likely to be white, to be insured, to have a history of coronary artery bypass graft and intravenous (IV) drug use, to be undergoing a concomitant vascular procedure, and to be discharged on an anticoagulant. In multivariable analysis, significant AVG infection within 3 months was associated with IV drug use history (odds ratio [OR], 5; 95% confidence interval [CI], 1.75-14.3; P = .003), discharge to a health care facility (OR, 2.66; 95% CI, 1.07-6.63; P = .035), discharge on an anticoagulant (OR, 2.31; 95% CI, 1.13-4.72; P = .021), white race (OR, 2.3; 95% CI, 1.21-4.34; P = .011), and female sex (OR, 2.02; 95% CI, 1.06-3.85; P = .033). Kaplan-Meier analysis showed that freedom from graft site infection at 1 year was 96.4%. Longer term graft infection at 1 year was independently associated with IV drug use history (hazard ratio [HR], 1.98; 95% CI, 1.06-3.68; P = .032), initial discharge to a health care facility (HR, 1.88; 95% CI, 1.19-2.97; P = .007), and white race (HR, 1.64; 95% CI, 1.23-2.19; P = .001). CONCLUSIONS: Although significant AVG infection was uncommon in the Vascular Quality Initiative, the majority were treated with graft removal. In select high-risk patients, extra care should be taken and alternative forms of arteriovenous access may be considered.


Assuntos
Derivação Arteriovenosa Cirúrgica , Medição de Risco/métodos , Infecção da Ferida Cirúrgica/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular
5.
Hand (N Y) ; 15(6): 870-876, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-30895817

RESUMO

Background: Our goal was to investigate patients' upper extremity tissue perfusion changes using an indocyanine green laser angiography imaging system for various pathologic states and interventions. Methods: This prospective observational study used Spy Elite/LUNA laser angiography to evaluate perfusion in patients with upper extremity vascular compromise. All patients had Spy Elite/LUNA imaging as well as clinical and handheld Doppler examinations preintervention, intraoperatively, if applicable, and at 1 week, 2 weeks, and 2 months postintervention. For each laser angiography scan, we used an unaffected control area with uninjured skin to quantitatively compare with the dysvascular tissues. Results: Twelve patients, 7 men and 5 women, had a total of 16 upper extremities evaluated. The mean age was 53 years, and half of the patients entering the study were smokers. Etiologies of vascular compromise were trauma, primary and secondary vasospastic disease, scleroderma, and intravascular drug injection. Interventions included surgical repair/reconstruction, botulinum toxin injections, and/or systemic medications. Improvement in perfusion following intervention was statistically significant, demonstrated by an increase in Spy Elite/LUNA quantitative score postintervention compared with preintervention scans. Adjusting for other variables, such as smoking and handheld Doppler signal status, demonstrated an independent statistically significant increase in Spy Elite/LUNA scores at all postintervention time points compared with preintervention scores. Laser angiography was able to confirm adequate vascular status, with ultimate tissue survival, in some cases when Doppler signals were not initially present. Conclusions: Laser angiography provided objective data to document improved upper extremity tissue perfusion following various interventions.


Assuntos
Extremidade Superior/irrigação sanguínea , Extremidade Superior/diagnóstico por imagem , Adulto , Idoso , Angiografia , Corantes , Feminino , Humanos , Verde de Indocianina , Lasers , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
6.
BMC Cardiovasc Disord ; 19(1): 211, 2019 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-31500561

RESUMO

BACKGROUND: Remote ischemic conditioning (RIC) is a procedure applied in a limb for triggering endogenous protective pathways in distant organs, namely brain or heart. The underlying mechanisms of RIC are still not fully understood, and it is hypothesized they are mediated either by humoral factors, immune cells and/or the autonomic nervous system. Herein, heart rate variability (HRV) was used to evaluate the electrophysiological processes occurring in the heart during RIC and, in turn to assess the role of autonomic nervous system. METHODS: Healthy subjects were submitted to RIC protocol and electrocardiography (ECG) was used to evaluate HRV, by assessing the variability of time intervals between two consecutive heart beats. This is a pilot study based on the analysis of 18 ECG from healthy subjects submitted to RIC. HRV was characterized in three domains (time, frequency and non-linear features) that can be correlated with the autonomic nervous system function. RESULTS: RIC procedure increased significantly the non-linear parameter SD2, which is associated with long term HRV. This effect was observed in all subjects and in the senior (> 60 years-old) subset analysis. SD2 increase suggests an activation of both parasympathetic and sympathetic nervous system, namely via fast vagal response (parasympathetic) and the slow sympathetic response to the baroreceptors stimulation. CONCLUSIONS: RIC procedure modulates both parasympathetic and sympathetic autonomic nervous system. Furthermore, this modulation is more pronounced in the senior subset of subjects. Therefore, the autonomic nervous system regulation could be one of the mechanisms for RIC therapeutic effectiveness.


Assuntos
Sistema Nervoso Autônomo/fisiologia , Frequência Cardíaca , Coração/inervação , Precondicionamento Isquêmico , Extremidade Superior/irrigação sanguínea , Adulto , Idoso , Barorreflexo , Eletrocardiografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Pressorreceptores/fisiologia , Fluxo Sanguíneo Regional , Fatores de Tempo
7.
Int Angiol ; 38(3): 239-249, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31112027

RESUMO

BACKGROUND: We prospectively analyzed the effect of preexisting structural changes of the radial artery (RA) wall by histological examination on the wrist radiocephalic fistula (RCF) outcomes. METHODS: During RCF creation, one segment of the RA wall was collected and its histomorphometric analysis was performed. The RCF function was evaluated by measuring blood flow rate. RESULTS: At the end of follow-up, 75.7% of the thirty-seven patients enrolled were performing hemodialysis by using their successful RCF and 24.3% of them showed early RCF failure. Compared to patients with a healthy RA, the RCF of those with medial RA microcalcification reached up a lower flow and a shorter primary patency (P=0.005 and P=0.040, respectively). The RA microcalcification was predictive of the RCF function (coefficient -614.9, 95% CI: -994.7 to -235.1, P=0.003). Compared to patients with successful RCF, those with failed RCF had a greater frequency of weak RCF thrill after releasing the clamps (P=0.045). Dependence on hemodialysis during RCF placement was predictive of its early failure (OR: 23.2, 95% CI: 1.76 to 306.9, P=0.017). Both having at least one cardiovascular comorbidity (HR 4.30, 95% CI: 1.29 to 14.39, P=0.018) and a thicker media layer of the RA (HR 1.60, 95% CI: 1.87 to 2.15, P=0.002) were predictive of primary RCF patency. CONCLUSIONS: The function and survival of the successful RCF were related to preoperative RA abnormalities such as microcalcification and media layer thickness. Both dependence on hemodialysis during RCF placement and an attenuated RCF thrill were associated with early RCF failure.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Esclerose Calcificante da Média de Monckeberg/complicações , Artéria Radial/patologia , Extremidade Superior/irrigação sanguínea , Grau de Desobstrução Vascular , Idoso , Idoso de 80 Anos ou mais , Feminino , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Calcificante da Média de Monckeberg/fisiopatologia , Análise Multivariada , Estudos Prospectivos , Artéria Radial/cirurgia , Radiografia , Análise de Regressão , Diálise Renal , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
8.
Hand Clin ; 35(2): 155-178, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30928048

RESUMO

Replantation and revascularization in the pediatric extremity has unique challenges that provide a fertile field of research and clinical experience. Children regenerate peripheral nerves rapidly, resulting in good sensory and motor function. They adapt well to functional deficits and mismatch errors of reinnervation. The technical aspects of microsurgical care in children can be challenging because the structures are small. Additional technical challenges include preservation of growth centers, prevention of vasospasm, protection of the reconstruction, and psychosocial care. Despite these challenges, children show excellent functional outcomes with minimal complications.


Assuntos
Amputação Traumática/cirurgia , Reimplante/métodos , Extremidade Superior/lesões , Extremidade Superior/cirurgia , Amputação Cirúrgica , Amputação Traumática/psicologia , Aneurisma/cirurgia , Anticoagulantes/uso terapêutico , Vasos Sanguíneos/transplante , Criança , Acessibilidade aos Serviços de Saúde , Disparidades nos Níveis de Saúde , Humanos , Hiperemia/terapia , Microcirurgia , Regeneração Nervosa , Pediatria , Nervos Periféricos/transplante , Cuidados Pós-Operatórios , Extremidade Superior/irrigação sanguínea , Extremidade Superior/inervação
9.
J Perianesth Nurs ; 33(5): 699-707, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29428831

RESUMO

PURPOSE: The purpose of our study was to evaluate effective ischemia and its associated complications using the limb occlusion pressure technique versus standard pneumatic ischemia technique. DESIGN: Single-centered randomized, controlled clinical trial. METHODS: One hundred sixty participants were randomized into two equal and parallel groups: (1) intervention group-LOP technique, and (2) control group-standard pneumatic ischemia technique. FINDINGS: Anesthetic incidences (need to administer analgesics for pain and/or hypnotics for anxiety) were similar in both groups. Statistically significant differences were observed for pain, hyperemia, and hospitalization, with higher values in the control group. Patients in the intervention group had, at 95% confidence, a 2.9 times greater chance of having optimal ischemia (assessed as 9 on the analog scale) than patients in the control group (odds ratio, 2.9; 95% confidence interval, 1.4 to 6.1). CONCLUSIONS: Intervention group patients had lower indexes of hyperemia, pain, and hospital stay.


Assuntos
Hiperemia/epidemiologia , Dor/epidemiologia , Torniquetes , Extremidade Superior/cirurgia , Adulto , Idoso , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Pressão , Extremidade Superior/irrigação sanguínea
10.
J Vasc Surg ; 67(2): 529-535.e1, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28943003

RESUMO

OBJECTIVE: Basilic vein transposition (BVT) fistulas may be performed as either a one-stage or two-stage operation, although there is debate as to which technique is superior. This study was designed to evaluate the comparative clinical efficacy and cost-effectiveness of one-stage vs two-stage BVT. METHODS: We identified all patients at a single large academic hospital who had undergone creation of either a one-stage or two-stage BVT between January 2007 and January 2015. Data evaluated included patient demographics, comorbidities, medication use, reasons for abandonment, and interventions performed to maintain patency. Costs were derived from the literature, and effectiveness was expressed in quality-adjusted life-years (QALYs). We analyzed primary and secondary functional patency outcomes as well as survival during follow-up between one-stage and two-stage BVT procedures using multivariate Cox proportional hazards models and Kaplan-Meier analysis with log-rank tests. The incremental cost-effectiveness ratio was used to determine cost savings. RESULTS: We identified 131 patients in whom 57 (44%) one-stage BVT and 74 (56%) two-stage BVT fistulas were created among 8 different vascular surgeons during the study period that each performed both procedures. There was no significant difference in the mean age, male gender, white race, diabetes, coronary disease, or medication profile among patients undergoing one- vs two-stage BVT. After fistula transposition, the median follow-up time was 8.3 months (interquartile range, 3-21 months). Primary patency rates of one-stage BVT were 56% at 12-month follow-up, whereas primary patency rates of two-stage BVT were 72% at 12-month follow-up. Patients undergoing two-stage BVT also had significantly higher rates of secondary functional patency at 12 months (57% for one-stage BVT vs 80% for two-stage BVT) and 24 months (44% for one-stage BVT vs 73% for two-stage BVT) of follow-up (P < .001 using log-rank test). However, there was no significant difference between groups in use of interventions (58% for one-stage BVT vs 51% for two-stage BVT; P = .5) to maintain patency. These findings were confirmed in multivariate analysis, in which two-stage BVTs were associated with a significantly lower rate of failure (hazard ratio, 0.39; 95% confidence interval, 0.2-0.8; P < .05) than one-stage BVTs after controlling for confounding variables. Finally, the two-stage BVT was more cost-effective (3.74 QALYs for two-stage BVT vs 3.32 QALYs for one-stage BVT) during 5 years, with an incremental cost-effectiveness ratio of $4681 per QALY. CONCLUSIONS: Our data show that two-stage BVTs are more durable and cost-effective than one-stage procedures, with significantly higher patency and lower rates of failure among comparable risk-stratified patients. These findings suggest that additional upfront costs and resources associated with creating two-stage BVTs are justified by their long-term outcomes.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Diálise Renal , Extremidade Superior/irrigação sanguínea , Veias/cirurgia , Centros Médicos Acadêmicos , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/economia , Distribuição de Qui-Quadrado , Pesquisa Comparativa da Efetividade , Análise Custo-Benefício , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Custos de Cuidados de Saúde , Humanos , Estimativa de Kaplan-Meier , Masculino , Cadeias de Markov , Pessoa de Meia-Idade , Modelos Econômicos , Análise Multivariada , Modelos de Riscos Proporcionais , Anos de Vida Ajustados por Qualidade de Vida , Diálise Renal/economia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Utah , Grau de Desobstrução Vascular , Veias/diagnóstico por imagem , Veias/fisiopatologia
11.
World J Surg ; 41(9): 2401-2408, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28484817

RESUMO

INTRODUCTION: Our novel technique of pen torch transillumination (PTI) uses a cheap and easily available instrument (Penlite-LP212®, Energizer®, Missouri, USA) to visualize superficial veins invisible to the naked eye. We evaluate the efficacy of PTI in improving venepuncture success rate (SR) for patients with poor venous access. METHODS: This prospective randomized controlled trial looked at adult patients (n = 69) aged 21-90 with difficult venous access (history of ≥3 consecutive attempts required for successful cannulation during the current admission) requiring non-emergent venepuncture. Patients underwent venepuncture over the upper-limb using one of the following: conventional venepuncture (control); Veinlite® EMS (TransLite®, Texas, USA), a commercial transillumination device; PTI. Outcome measures were: successful cannulation within 2 attempts and total duration of venepuncture. Fisher's exact and Kruskal-Wallis tests were performed. RESULTS: A significantly larger number of patients had successful venepuncture within 2 attempts using PTI (22/23, 95.7%) and Veinlite (23/23, 100%), compared to the controls (7/23, 30.4%) (p < 0.05). The total duration required for successful venepuncture was significantly shorter for Veinlite (mean 3.7 min, 1.0-5.3 min) and PTI (mean 8.5 min, range 1.08-27 min) compared to the controls (mean 23.2 min, range 1.88-46.5 min) (p < 0.05). CONCLUSIONS: PTI allows users to visualize veins invisible to the naked eye. Thrombosed/tortuous veins, branch points and valves, are easily identified and avoided. It has comparable efficacy to Veinlite® and is cheaper (Veinlite®-USD 227 vs. Penlite-LP212®-USD 7.00) and more easily available. PTI improves patient care, especially in developing regions where costs are a concern.


Assuntos
Flebotomia/métodos , Transiluminação/instrumentação , Veias/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo , Equipamentos e Provisões/economia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Extremidade Superior/irrigação sanguínea
12.
Clin Physiol Funct Imaging ; 37(4): 437-441, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26778036

RESUMO

Total occlusion pressure (TOP) is an important variable to ischaemic exercise training because the optimal pressure of flow restriction (OPR), applied during this exercise modality, is derived from it. Despite the common use of Doppler ultrasound (DU) to determine the TOP, the reproducibility of this assessment was not evaluated yet. Given this, the objective was to evaluate the reproducibility of DU for the measurement of TOP in upper limbs and determine the predictive variables. Thirteen male volunteers attended three times to the laboratory. On the 1st day, we assessed arm circumference (AC), systolic blood pressure (SBP) and diastolic (DBP), and brachial artery TOP. On 2nd and 3rd days, only TOP was assessed. We found a coefficient of variation of 5·6% and an intraclass correlation coefficient of 0·795 for the DU. In the analysis of TOP predictive variables, the Spearman coefficients (R) were 0·813 (SBP), 0·786 (DBP) and 0·388 (AC). Therefore, these results support that DU has good reproducibility for the TOP and that SBP and DBP should be considered to the determination of TOP in upper limbs.


Assuntos
Pressão Sanguínea , Artéria Braquial/diagnóstico por imagem , Isquemia , Torniquetes , Ultrassonografia Doppler , Extremidade Superior/irrigação sanguínea , Adulto , Velocidade do Fluxo Sanguíneo , Artéria Braquial/fisiologia , Estudos Transversais , Humanos , Masculino , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Adulto Jovem
13.
Ann Vasc Surg ; 40: 98-104, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27903474

RESUMO

BACKGROUND: Patients suffering blunt thoracic aortic injury (BTAI) can be treated by use of thoracic endovascular aortic repair (TEVAR). In this setting, the coverage of the left subclavian artery (LSA) is frequently necessary. Nevertheless, the functionality of the upper left extremity after TEVAR had been rarely analyzed. Thus, this study intends to underline the safety of TEVAR as well as to determine the functionality of the left arm after coverage of the LSA. METHODS: All patients suffering from BTAI treated by endovascular means in 3 centers (Aachen [Germany], Maastricht [Netherlands], and Innsbruck [Austria]) between 1996 and 2009 were retrospectively analyzed. The safety of the procedure had been assessed by the morbidity and mortality rate. The mid-term functional status of the upper left extremity was evaluated by using the DASH score (disabilities of the arm shoulder and hand). RESULTS: Forty-six patients (40 male, 6 female), mean age 39.4 ± 16.9 years suffered from BTAI caused by traffic accident (n = 31 [67.39%]), by skiing injury (n = 8 [17.39%]), and by fall (n = 7 [15.21%]). All patients underwent TEVAR, the technical success rate was 100%; 1 carotid-carotid subclavian bypass implantation was necessary. LSA coverage was performed in 76% (35/46) of the cases. Total complication rate was 17.3% (8/46); the endoleak rate was 8.6% (4/46) (2 × Ib, 1 × IIa, 1 × IV). Further complications were bypass and endograft occlusion. The postoperative mortality rate was 6% (3/46), the DASH score was completed in 65% (30/46). The study population reached a mean value of 17 ± 20, which is comparable to a nonharmed reference group (10.10 ± 14.68). A significant correlation between the DASH score and patients age could be demonstrated (2-sided P value: 0.0213). CONCLUSIONS: Endovascular therapy of BTAI revealed a good primary success rate. An adequate mid-term functional status of the upper left extremity could be assessed in comparison to a nonharmed reference group.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Avaliação de Processos em Cuidados de Saúde , Artéria Subclávia/cirurgia , Extremidade Superior/irrigação sanguínea , Ferimentos não Penetrantes/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/lesões , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Comorbidade , Avaliação da Deficiência , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Artéria Subclávia/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/mortalidade , Adulto Jovem
14.
J Vasc Access ; 16(6): 480-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26070094

RESUMO

INTRODUCTION: Socioeconomic deprivation is an important factor in determining poor health and is associated with a higher prevalence of many chronic diseases including diabetes and renal failure, and often poorer outcomes for patients with such conditions. The influence of deprivation on outcomes following vascular access surgery has not previously been reported. METHODS: The Welsh Index of Multiple Deprivation was used to assess the influence of socioeconomic deprivation on outcomes following 507 consecutive first upper limb arteriovenous (AV) fistulas from a single institution in the United Kingdom, performed between 2011 and 2014. The primary outcome measures were early failure and maturation into a working fistula. RESULTS: Four hundred and five (80%) patients had a patent AV fistula at the 2-week follow-up clinic. Three hundred and fifty-nine (71%) patients developed a functionally mature AV fistula as determined by clinical assessment and a Doppler scan. There were no differences in either early failure rates (p = 0.95) or maturation rates (p = 0.77) between the least and most deprived groups of patients. CONCLUSIONS: In conclusion, this study has shown that socioeconomic deprivation does not influence outcomes following vascular access surgery.


Assuntos
Derivação Arteriovenosa Cirúrgica/economia , Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde/economia , Nefropatias/economia , Nefropatias/terapia , Pobreza , Avaliação de Processos em Cuidados de Saúde/economia , Diálise Renal/economia , Extremidade Superior/irrigação sanguínea , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Comorbidade , Feminino , Humanos , Nefropatias/diagnóstico , Nefropatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Diálise Renal/efeitos adversos , Fatores de Risco , Fatores de Tempo , Falha de Tratamento , Ultrassonografia Doppler , Grau de Desobstrução Vascular , País de Gales/epidemiologia , Adulto Jovem
15.
Saudi J Kidney Dis Transpl ; 26(2): 279-84, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25758875

RESUMO

Venography is an invasive diagnostic test that uses contrast material that provides a picture of the condition of the veins. But, complications, including adverse effects on the kidney, do occur. On the other hand, with the current technological development, application of ultrasound in the diagnosis of obstructive diseases of the veins is gaining popularity, being non-invasive, easy to perform and cost-effective. The aim of this study was to evaluate the diagnostic value of Doppler sonography in the diagnosis of central vein stenosis. In this descriptive-analytical study, 41 hemodialysis patients who had been referred for 50 upper limb venographies to the radiology department of Imam Reza (AS) were included. Patients with chronic kidney disease with a history of catheterization of the vein, jugular or subclavian, and who had established fistulas or synthetic vascular grafts were targeted. Central venous ultrasound was performed on both sides to evaluate stenosis or occlusion. Venography was performed by the radiologist the next day or the day before hemodialysis. Data on demographic characteristics, findings of clinical examination and findings of ultrasound as well as venography were recorded by using the SPSS software, Chi-square test and Spearman correlation, and Kappa agreement was calculated for sensitivity, specificity and predictive values. Twenty-three (56%) patients were male subjects and 18 patients (44%) were female. Twenty-three (56%) patients of the study population were aged <60 years and 18 (43/9%) patients were aged >60 years. The overall sensitivity, specificity and positive predictive value and negative predictive value of Doppler sonography in the proximal veins in hemodialysis patients compared with venography were, respectively, 80.9%, 79.3%, 73.9% and 85.1%. Color Doppler sonography, as a non-invasive method, could be a good alternative for venography in the assessment of the upper limb with central vein stenosis and occlusion.


Assuntos
Diálise Renal , Insuficiência Renal Crônica/terapia , Ultrassonografia Doppler em Cores , Extremidade Superior/irrigação sanguínea , Doenças Vasculares/diagnóstico por imagem , Distribuição de Qui-Quadrado , Constrição Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Valor Preditivo dos Testes , Diálise Renal/efeitos adversos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Índice de Gravidade de Doença , Doenças Vasculares/etiologia , Veias/diagnóstico por imagem
16.
J Am Osteopath Assoc ; 114(12): 918-29, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25429082

RESUMO

CONTEXT: The first 2 years of osteopathic medical school involve training in osteopathic principles and practice, including understanding the tenets of osteopathic medicine and developing palpatory skills for clinical application. Although this training emphasizes the link between somatic dysfunction and physiologic function, it does not include the opportunity for students to quantitatively assess the physiologic effect of osteopathic manipulative treatment (OMT) using physiologic measurements. OBJECTIVE: To evaluate an approach for integrated OMT training coupled with physiologic measurements of relevant parameters, whereby first-year osteopathic medical students assess the quantitative, real-time changes in specific physiologic signals during instruction. METHODS: During mandatory musculoskeletal and cardiovascular demonstration laboratories at a single osteopathic medical school, students were divided into small groups and performed OMT on each other while recording real-time measurements of physiologic functions such as maximum clench force, time to fatigue for the forearm flexor muscles, heart rate, and peripheral vascular flow. After data were collected, students analyzed pre- and post-OMT measurements and discussed underlying physiologic principles in a large group format. At the end of the sessions, students completed a brief survey on the usefulness of the integrated laboratories. RESULTS: Overall, 13 of 28 student groups (46.4%) measured a pre- to post-OMT increase in maximum clench force, and 16 (57.1%) observed an increase in time to fatigue for the forearm flexor muscles. Twenty-three of 27 student groups (85.2%) observed a reduction in heart rate and 19 (70.4%) measured an increase in peripheral vascular flow after OMT. Student satisfaction was generally favorable, with overall mean (SD) ratings of 6.38 (1.86) for the musculoskeletal laboratory and 7.81 (1.69) for the cardiovascular laboratory out of a maximum of 10 points. In open-ended comments, students deemed the combined laboratories as clinically applicable but desired more time for completing the laboratories. CONCLUSION: Measurement of specific physiologic musculoskeletal and cardiovascular parameters before and after OMT enabled quantification of physiologic responses to OMT. Students' favorable feedback indicated that the quality of learning in the laboratories was enhanced by the addition of physiologic measurements.


Assuntos
Retroalimentação , Osteopatia/educação , Medicina Osteopática/educação , Estudantes de Medicina , Frequência Cardíaca , Humanos , Fadiga Muscular , Fluxo Sanguíneo Regional , Inquéritos e Questionários , Extremidade Superior/irrigação sanguínea
17.
J Vasc Access ; 15(6): 448-60, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25198822

RESUMO

PURPOSE: Arteriovenous graft patency is limited by terminal occlusion caused by intimal hyperplasia (IH). Motivated by evidence that flow disturbances promote IH progression, a modular anastomotic valve device (MAVD) was designed to isolate the graft from the circulation between dialysis periods (closed position) and enable vascular access during dialysis (open position). The objective of this study was to perform a preliminary computational assessment of the device ability to normalize venous flow between dialysis periods and potentially limit IH development and thrombogenesis. METHODS: Computational fluid dynamics simulations were performed to compare flow and wall shear stress (WSS) in a native vein and MAVD prototypes featuring anastomotic angles of 90° and 30°. Low WSS (LWSS) regions prone to IH development were characterized in terms of temporal shear magnitude (TSM), oscillatory shear index (OSI), and relative residence time (RRT). Thrombogenic potential was assessed by investigating the loading history of fluid particles traveling through the device. RESULTS: The closed MAVD exhibited the same flow characteristics as the native vein (0.3% difference in pressure drop, 3.5% difference in surface-averaged WSS). The open MAVD generated five LWSS regions (TSM <0.5 Pa) exhibiting different degrees of flow reversal (surface-averaged OSI: 0.03-0.36) and stagnation (max RRT: 2.50-37.16). Reduction in anastomotic angle resulted in the suppression of three LWSS regions and overall reductions in flow reversal (surface-averaged OSI <0.21) and stagnation (max RRT <18.05). CONCLUSIONS: This study suggests the ability of the MAVD to normalize venous flow between dialysis periods while generating the typical hemodynamics of end-to-side vein-graft anastomoses during dialysis.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Simulação por Computador , Oclusão de Enxerto Vascular/prevenção & controle , Hemodinâmica , Modelos Cardiovasculares , Diálise Renal , Trombose/prevenção & controle , Extremidade Superior/irrigação sanguínea , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Teste de Materiais , Desenho de Prótese , Fluxo Sanguíneo Regional , Fatores de Risco , Estresse Mecânico , Trombose/etiologia , Trombose/fisiopatologia , Grau de Desobstrução Vascular
18.
J Vasc Access ; 15(4): 251-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24811603

RESUMO

BACKGROUND: According to the 2011 Infusion Nursing Standards of Practice, the low pH of intravenous vancomycin requires that it be administered through a central line. However, a careful review of the literature and a retrospective analysis of the experience at New York Hospital Queens (NYHQ) did not support the position of the Standards. PURPOSE: A prospective, controlled, randomized clinical trial was conducted to determine if intravenous vancomycin could be safely administered through a novel midline catheter (POWERWAND®, Access Scientific, San Diego, CA). METHODS: Patients scheduled to receive short-term (<6 days) intravenous vancomycin were randomly assigned to receive treatment through either a peripherally inserted central catheter (PICC) or the midline study device. Complications and the costs of insertion were recorded. RESULTS: The two groups did not differ significantly with respect to total complications (17.9% with PICCs vs. 19.9% with the midline), phlebitis (0% vs. 0%) or thrombosis (0% vs. 0%). One suspected catheter-associated bloodstream infection did occur in the PICC group. Insertion costs were $90.00 less per insertion in the midline group. CONCLUSIONS: Short-term intravenous vancomycin can be safely and cost-efficiently administered in the deep vessels of the upper arm using the midline study device.


Assuntos
Antibacterianos/administração & dosagem , Cateterismo Venoso Central/instrumentação , Cateterismo Periférico/instrumentação , Cateteres de Demora , Cateteres Venosos Centrais , Extremidade Superior/irrigação sanguínea , Vancomicina/administração & dosagem , Idoso , Antibacterianos/efeitos adversos , Obstrução do Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/economia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/economia , Cateteres de Demora/economia , Cateteres Venosos Centrais/economia , Redução de Custos , Análise Custo-Benefício , Esquema de Medicação , Desenho de Equipamento , Feminino , Custos de Cuidados de Saúde , Humanos , Concentração de Íons de Hidrogênio , Infusões Intravenosas , Masculino , Cidade de Nova Iorque , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia , Fatores de Tempo , Resultado do Tratamento , Trombose Venosa Profunda de Membros Superiores/etiologia , Vancomicina/efeitos adversos
19.
Ann Vasc Surg ; 28(4): 964-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24370501

RESUMO

BACKGROUND: Race and insurance status are seen as potential barriers to health care access and maintenance. Our goal was to see how these, as well as other patient and procedural characteristics, affected our populations' upper extremity vascular access outcomes. METHODS: We retrospectively reviewed 601 vascular access patients from 2004 through 2012 in our urban university hospital. We recorded patient demographics, insurance status, comorbidities, and complications. Primary outcomes were reintervention, long-term mortality, and transplantation. RESULTS: Median age was 62 ± 15.8 years, and 58% were male. Most operations were arteriovenous fistulas (66%). The majority of patients identified themselves as Hispanic (50%), followed by white (22%), and black (19%). Most patients had Medicare only (42%), 31% had private insurance, and 27% had Medicaid as their insurance. Black/African American patients were more likely to receive an arteriovenous graft (AVG) compared with white and Hispanic patients (44% vs. 28% and 33%, P < 0.05). White patients were significantly older (68) than Hispanics (61) or blacks (58). Freedom from reintervention at 5 years was 55% with previous tunneled catheter use predictive. Mortality at 5 years was 35% and predicted by age, AVG placement, white race, and not receiving a kidney transplant. Predictors of not receiving a transplant included older age, lower albumin, AVG placement, and coronary artery disease. CONCLUSIONS: There were no disparities with insurance status in long-term outcomes in our population. Race was not a factor for reintervention or transplantation; however, black/African American patients were more likely have an AVG placed, and white patients had a lower long-term survival after access placement.


Assuntos
Derivação Arteriovenosa Cirúrgica , Implante de Prótese Vascular , Acessibilidade aos Serviços de Saúde , Disparidades nos Níveis de Saúde , Cobertura do Seguro , Seguro Saúde , Grupos Raciais , Diálise Renal , Extremidade Superior/irrigação sanguínea , Fatores Etários , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/economia , Derivação Arteriovenosa Cirúrgica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/economia , Implante de Prótese Vascular/mortalidade , Cateterismo Venoso Central , Comorbidade , Feminino , Acessibilidade aos Serviços de Saúde/economia , Hospitais Universitários , Humanos , Cobertura do Seguro/economia , Seguro Saúde/economia , Transplante de Rim , Masculino , Medicaid , Medicare , Pessoa de Meia-Idade , Setor Privado , Diálise Renal/efeitos adversos , Diálise Renal/economia , Diálise Renal/mortalidade , Estudos Retrospectivos , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia , Saúde da População Urbana
20.
J Vasc Access ; 14(4): 348-55, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23817956

RESUMO

PURPOSE: The aim of this work was to establish the relationship between traditional blood vessel mapping for vascular access (VA) creation by B-mode ultrasound (US) and novel non contrast-enhanced magnetic resonance angiography (NCE-MRA), and to study the potential influence of the diameter assessment technique on the choice of hemodialysis vascular access. METHODS: A total of 27 end-stage renal-disease patients were included. They received routine US and a NCE-MRA examination of the upper extremity. Diameters were measured manually on US and semi-automatically on NCE-MRA. These measurements were statistically compared for the arteries and veins and for each measurement location. Furthermore, sensitivity and specificity of both modalities to predict VA location was investigated by comparison with an experienced surgeon. This analysis gave insight into the potential influence of vessel mapping modality on decision-making. RESULTS: Comparison of NCE-MRA with US for the arteries and veins, demonstrated a bias of 9% (limits -33%-78%) and 38% (limits -36%-198%), respectively. Statistically significant differences between the modalities on the individual locations were mainly found for the venous locations. The sensitivity and specificity for US to predict VA location was 1.0 and 0.74, respectively, while for NCE-MRA this was 0.88 and 0.39, respectively. CONCLUSIONS: The results obtained indicate that extreme caution should be exercised when replacing one diameter measurement modality with the other. A further need exists to improve both vessel mapping protocols to obtain a geometric description of the upper extremity vasculature regardless of acquisition modality.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Falência Renal Crônica/terapia , Angiografia por Ressonância Magnética , Diálise Renal , Ultrassonografia Doppler Dupla , Extremidade Superior/irrigação sanguínea , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias/diagnóstico por imagem , Artérias/patologia , Artérias/cirurgia , Técnicas de Apoio para a Decisão , Feminino , Humanos , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Veias/diagnóstico por imagem , Veias/patologia , Veias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA