Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 503
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Clin Sleep Med ; 20(8): 1259-1266, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38525926

RESUMO

STUDY OBJECTIVES: Venous blood gases (VBGs) are not consistently considered suitable surrogates for arterial blood gases (ABGs) in assessing acute respiratory failure due to variable measurement error. The physiological stability of patients with chronic ventilatory failure may lead to improved agreement in this setting. METHODS: Adults requiring ABGs for sleep or ventilation titration studies had VBGs drawn before or after each ABG, in a randomized order. Veno-arterial correlation and agreement were examined for carbon dioxide tension (PCO2), pH, oxygen tension (PO2), and oxygen saturation (SO2). RESULTS: We analyzed 115 VBG-ABG pairs from 61 patients. Arterial and venous measures were correlated (P < .05) for PCO2 (r = .84) and pH (r = .72), but not for PO2 or SO2. Adjusted mean veno-arterial differences (95% limits of agreement) were +5.0 mmHg (-4.4 to +14.4) for PCO2; -0.02 (-0.09 to +0.04) for pH; -34.3 mmHg (-78.5 to +10.0) for PO2; and -23.9% (-61.3 to +13.5) for SO2. VBGs obtained from the dorsal hand demonstrated a lower mean PCO2 veno-arterial difference (P < .01). A venous PCO2 threshold of ≥ 45.8 mmHg was > 95% sensitive for arterial hypercapnia, so measurements below this can exclude the diagnosis without an ABG. A venous PCO2 threshold of ≥ 53.7 mmHg was > 95% specific for arterial hypercapnia, so such readings can be assumed diagnostic. The area under the receiver operating characteristic curve of 0.91 indicated high discriminatory capacity. CONCLUSIONS: A venous PCO2 < 45.8 mmHg or ≥ 53.7 mmHg would exclude or diagnose hypercapnia, respectively, in patients referred for sleep studies, but VBGs are poor surrogates for ABGs where precision is important. CLINICAL TRIAL REGISTRATION: Registry: Australian New Zealand Clinical Trials Register; Name: A comparison of arterial and blood gas analyses in sleep studies; URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=372717; Identifier: ACTRN12617000562370. CITATION: Lindstrom SJ, McDonald CF, Howard ME, et al. Venous blood gases in the assessment of respiratory failure in patients undergoing sleep studies: a randomized study. J Clin Sleep Med. 2024;20(8):1259-1266.


Assuntos
Gasometria , Insuficiência Respiratória , Humanos , Masculino , Gasometria/métodos , Feminino , Insuficiência Respiratória/sangue , Insuficiência Respiratória/diagnóstico , Pessoa de Meia-Idade , Dióxido de Carbono/sangue , Polissonografia/métodos , Adulto , Veias/fisiopatologia , Oxigênio/sangue , Idoso , Concentração de Íons de Hidrogênio
2.
BMC Vet Res ; 19(1): 241, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980491

RESUMO

BACKGROUND: The oxygen reserve index (ORi) is a real-time, continuous index measured with multi-wavelength pulse CO-oximetry technology. It estimates mild hyperoxemia in humans, which is defined as a partial pressure of oxygen (PaO2) level between 100 and 200 mmHg. The objectives of this study were to assess the correlation between ORi and PaO2, as well as to determine its ability in detecting mild hyperoxemia in dogs. METHODS: This prospective observational study enrolled 37 anaesthetised and mechanically ventilated dogs undergoing elective procedures. Simultaneous measurements of ORi and PaO2 were collected, using a multi-wavelength pulse CO-oximeter with a probe placed on the dog's tongue, and a blood gas analyser, respectively. A mixed-effects model was used to calculate the correlation (r2) between simultaneous measurements of ORi and PaO2. The trending ability of ORi to identify dependable and proportional changes of PaO2 was determined. The diagnostic performances of ORi to detect PaO2 ≥ 150 mmHg and ≥ 190 mmHg were estimated using the area under the receiver operating characteristic curve (AUROC). The effects of perfusion index (PI), haemoglobin (Hb), arterial blood pH and partial pressure of carbon dioxide (PaCO2) on AUROC for PaO2 ≥ 150 mmHg were evaluated. RESULTS: A total of 101 paired measurements of ORi and PaO2 were collected. PaO2 values ranged from 74 to 258 mmHg. A strong positive correlation (r2 = 0.52, p < 0.001) was found between ORi and PaO2. The trending ability ORi was 90.7%, with 92% sensitivity and 89% specificity in detecting decreasing PaO2. An ORi value ≥ 0.53 and ≥ 0.76 indicated a PaO2 ≥ 150 and ≥ 190 mmHg, respectively, with ≥ 82% sensitivity, ≥ 77% specificity and AUROC ≥ 0.75. The AUROC of ORi was not affected by PI, Hb, pH and PaCO2. CONCLUSIONS: In anaesthetised dogs, ORi may detect mild hyperoxaemia, although it does not replace blood gas analysis for measuring the arterial partial pressure of oxygen. ORi monitoring could be used to non-invasively assess oxygenation in dogs receiving supplemental oxygen, limiting excessive hyperoxia.


Assuntos
Oximetria , Oxigênio , Animais , Cães , Artérias , Gasometria/veterinária , Oximetria/veterinária , Oximetria/métodos , Estudos Prospectivos
3.
Res Vet Sci ; 154: 52-58, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36459719

RESUMO

To evaluate the interference of postprandial lipemia on blood gas parameters and to assess the acid-base status by the quantitative approach of the strong ion model blood samples of 15 healthy dogs were collected during fasting (0 h) and at one (1 h), three (3 h) and five (5 h) hours after the induction of lipemia with a hypercaloric diet. Total cholesterol (TC) and triglyceride (TG) levels were used to assess lipemia and these were correlated with the parameters evaluated accordingly. Anion gap decreased at 5 h without correlation with TC and TG, whereas other parameters measured by the blood gasometer did not change. In the evaluation of the acid base state, the apparent strong ion difference (SIDa) and the strong ion gap (SIG) showed a decrease at 5 h without correlation with lipemia. Lipid levels correlated with the effective strong ion difference (SIDe), the concentration of total non-volatile weak acids (Atot), albumin, phosphate, and magnesium. The SIDe increased at 1 h and at 3 h; the Atot at 1 h, 3 h, and 5 h; albumin increased at 1 h and 3 h; phosphate increased at 1 h, 3 h and 5 h; and magnesium decreased at 5 h. Though postprandial lipemia does not interfere with blood gas analysis, it can cause errors in the variables used to assess the acid-base status, which are dependent on biochemical analytes. Therefore, caution is required when interpreting electrolyte disturbances that result from the postprandial state.


Assuntos
Doenças do Cão , Hiperlipidemias , Cães , Animais , Magnésio , Equilíbrio Ácido-Base , Hiperlipidemias/veterinária , Gasometria/veterinária , Albuminas , Triglicerídeos , Doenças do Cão/diagnóstico
4.
J Vet Emerg Crit Care (San Antonio) ; 33(1): 123-127, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36468292

RESUMO

OBJECTIVE: To evaluate the variability in arterial blood gas (ABG) assessment of pulmonary function with different body positioning in dogs with suspected aspiration pneumonia. KEY FINDINGS: The median differences in alveolar-arterial gradient, Pao2 , and Paco2 values in different recumbencies were not statistically significantly different, both within patients and across the study population. No difference was noted in ABG values in the subgroups with unilateral or bilateral disease or that were more affected on the right side versus the left side. SIGNIFICANCE: This preliminary study provides data that can be used to calculate appropriate sample sizes for subsequent studies investigating the impact of recumbency on pulmonary function in patients with aspiration pneumonia.


Assuntos
Doenças do Cão , Pneumonia Aspirativa , Cães , Animais , Posicionamento do Paciente/veterinária , Pulmão , Pneumonia Aspirativa/diagnóstico , Pneumonia Aspirativa/veterinária , Gasometria/veterinária , Oxigênio , Doenças do Cão/diagnóstico
5.
Chest ; 160(5): e399-e408, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34339688

RESUMO

The existing coverage criteria for noninvasive ventilation (NIV) do not recognize the benefits of early initiation of NIV for those with thoracic restrictive disorders and do not address the unique needs for daytime support as the patients progress to ventilator dependence. This document summarizes the work of the thoracic restrictive disorder Technical Expert Panel working group. The most pressing current coverage barriers identified were: (1) delays in implementing NIV treatment; (2) lack of coverage for many nonprogressive neuromuscular diseases; and (3) lack of clear policy indications for home mechanical ventilation (HMV) support in thoracic restrictive disorders. To best address these issues, we make the following key recommendations: (1) given the need to encourage early initiation of NIV with bilevel positive airway pressure devices, we recommend that symptoms be considered as a reason to initiate therapy even at mildly reduced FVCs; (2) broaden CO2 measurements to include surrogates such as transcutaneous, end-tidal, or venous blood gas; (3) expand the diagnostic category to include phrenic nerve injuries and disorders of central drive; (4) allow a bilevel positive airway pressure device to be advanced to an HMV when the vital capacity is < 30% or to address severe daytime respiratory symptoms; and (5) provide additional HMV when the patient is ventilator dependent with use > 18 h per day. Adoption of these proposed recommendations would result in the right device, at the right time, for the right type of patients with thoracic restrictive disorders.


Assuntos
Serviços de Assistência Domiciliar , Medicare , Doenças Neuromusculares , Ventilação não Invasiva , Insuficiência Respiratória , Doenças Torácicas , Gasometria/métodos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Serviços de Assistência Domiciliar/organização & administração , Serviços de Assistência Domiciliar/normas , Humanos , Medicare/organização & administração , Medicare/normas , Doenças Neuromusculares/complicações , Doenças Neuromusculares/diagnóstico , Doenças Neuromusculares/fisiopatologia , Ventilação não Invasiva/instrumentação , Ventilação não Invasiva/métodos , Seleção de Pacientes , Insuficiência Respiratória/sangue , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Doenças Torácicas/complicações , Doenças Torácicas/diagnóstico , Estados Unidos
6.
Scand J Trauma Resusc Emerg Med ; 29(1): 79, 2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34090500

RESUMO

BACKGROUND: Mechanical chest compression devices are accepted alternatives for cardiopulmonary resuscitation (CPR) under specific circumstances. Current devices lack prospective and comparative data on their specific cardiovascular effects and potential for severe thoracic injuries. OBJECTIVES: To compare CPR effectiveness and thoracic injuries of two mechanical chest compression devices in pigs. STUDY DESIGN: Prospective randomised trial. ANIMALS: Eighteen male German landrace pigs. METHODS: Ventricular fibrillation was induced in anaesthetised and instrumented pigs and the animals were randomised into two intervention groups. Mechanical CPR was initiated by means of LUCAS™ 2 (mCCD1) or Corpuls™ cpr (mCCD2) device. Advanced life support was applied for a maximum of 10 cycles and animals achieving ROSC were monitored for 8 h. Ventilation/perfusion measurements were performed and blood gas analyses were taken. Thoracic injuries were assessed via a standardised damage score. RESULTS: Five animals of the mCCD1 group and one animal of the mCCD2 group achieved ROSC (p = 0.048). Only the mCCD1 animals survived until the end of the monitoring period (p < 0.01). MCCD1 animals showed less pulmonary shunt (p = 0.025) and higher normal V/Q (p = 0.017) during CPR. MCCD2 animals showed significantly more severe thoracic injuries (p = 0.046). CONCLUSION: The LUCAS 2 device shows superior resuscitation outcomes and less thoracic injuries compared to Corpuls cpr when used for experimental CPR in juvenile pigs. Researchers should be aware that different mCCDs for experimental studies may significantly influence the respective outcome of resuscitation studies and affect comparability of different trials. Controlled human and animal CPR studies and a standardised post-resuscitation injury evaluation could help to confirm potential hazards. TRIAL REGISTRATION: Trial approval number: G16-1-042-E4.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Traumatismos Torácicos , Animais , Humanos , Masculino , Gasometria , Reanimação Cardiopulmonar/efeitos adversos , Reanimação Cardiopulmonar/instrumentação , Parada Cardíaca/terapia , Parada Cardíaca/veterinária , Pressão , Estudos Prospectivos , Suínos , Traumatismos Torácicos/epidemiologia , Traumatismos Torácicos/veterinária , Tórax , Fibrilação Ventricular
7.
Emerg Med J ; 38(9): 711-717, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33789938

RESUMO

BACKGROUND: ABG samples are often obtained in trauma patients to assess shock severity. Venous blood gas (VBG) sampling, which is less invasive, has been widely used to assess other forms of shock. The study aim was to determine the agreement between VBG and ABG measurements in trauma. METHODS: Patients were enrolled at an Australian trauma centre between October 2016 and October 2018. Bland-Altman limits of agreement (LOA) between paired blood gas samples taken <30 min apart were used to quantify the extent of agreement. The impact of using only VBG measurements was considered using an a priori plan. Cases where venous sampling failed to detect 'concerning levels' were flagged using evidence-based cut-offs: pH ≤7.2, base deficit (BD) ≤-6, bicarbonate <21 and lactate ≥4. Case summaries of these patients were assessed by independent trauma clinicians as to whether an ABG would change expected management. RESULTS: During the study period 176 major trauma patients had valid paired blood gas samples available for analysis. The median time difference between paired measurements was 11 min (IQR 6-17). There was a predominance of men (81.8%) and blunt trauma (92.0%). Median Injury Severity Score was 13 (range 1-75) and inpatient mortality was 6.3%. Mean difference (ABG-VBG) and LOA between paired arterial and venous measurements were 0.036 (LOA -0.048 to 0.120) for pH, -1.27 mmol/L (LOA -4.35 to 1.81) for BD, -0.64 mmol/L (LOA -1.86 to 0.57) for lactate and -1.97 mmol/L (LOA -5.49 to 1.55) for bicarbonate. Independent assessment of the VBG 'false negative' cases (n=20) suggested an ABG would change circulatory management in two cases. CONCLUSIONS: In trauma patients VBG and ABG parameters displayed suboptimal agreement. However, in cases flagged as VBG 'false negative' independent review indicated that the availability of an ABG was unlikely to change management.


Assuntos
Gasometria , Choque Traumático/sangue , Veias , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Feminino , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Centros de Traumatologia
8.
Am J Emerg Med ; 44: 116-120, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33588251

RESUMO

OBJECTIVE: We assessed the performance of the ratio of peripheral arterial oxygen saturation to the inspired fraction of oxygen (SpO2/FiO2) to predict the ratio of partial pressure arterial oxygen to the fraction of inspired oxygen (PaO2/FiO2) among patients admitted to our emergency department (ED) during the SARS-CoV-2 outbreak. METHODS: We retrospectively studied patients admitted to an academic-level ED in France who were undergoing a joint measurement of SpO2 and arterial blood gas. We compared SpO2 with SaO2 and evaluated performance of the SpO2/FiO2 ratio for the prediction of 300 and 400 mmHg PaO2/FiO2 cut-off values in COVID-19 positive and negative subgroups using receiver-operating characteristic (ROC) curves. RESULTS: During the study period from February to April 2020, a total of 430 arterial samples were analyzed and collected from 395 patients. The area under the ROC curves of the SpO2/FiO2 ratio was 0.918 (CI 95% 0.885-0.950) and 0.901 (CI 95% 0.872-0.930) for PaO2/FiO2 thresholds of 300 and 400 mmHg, respectively. The positive predictive value (PPV) of an SpO2/FiO2 threshold of 350 for PaO2/FiO2 inferior to 300 mmHg was 0.88 (CI95% 0.84-0.91), whereas the negative predictive value (NPV) of the SpO2/FiO2 threshold of 470 for PaO2/FiO2 inferior to 400 mmHg was 0.89 (CI95% 0.75-0.96). No significant differences were found between the subgroups. CONCLUSIONS: The SpO2/FiO2 ratio may be a reliable tool for hypoxemia screening among patients admitted to the ED, particularly during the SARS-CoV-2 outbreak.


Assuntos
COVID-19/epidemiologia , Hipóxia/sangue , Hipóxia/diagnóstico , Oxigênio/sangue , Adulto , Idoso , Gasometria/métodos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos
9.
Vet Anaesth Analg ; 48(3): 297-304, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33610477

RESUMO

OBJECTIVE: To compare values of haemoglobin concentration (SpHb), arterial haemoglobin saturation (SpO2) and calculated arterial oxygen content (SpOC), measured noninvasively with a pulse co-oximeter before and after in vivo adjustment (via calibration of the device using a measured haemoglobin concentration) with those measured invasively using a spectrophotometric-based blood gas analyser in anaesthetized dogs. STUDY DESIGN: Prospective observational clinical study. ANIMALS: A group of 39 adult dogs. METHODS: In all dogs after standard instrumentation, the dorsal metatarsal artery was catheterised for blood sampling, and a pulse co-oximeter probe was applied to the tongue for noninvasive measurements. Paired data for SpHb, SpO2 and SpOC from the pulse co-oximeter and haemoglobin arterial oxygen saturation (SaO2) and arterial oxygen content (CaO2) from the blood gas analyser were obtained before and after in vivo adjustment. Bland-Altman analysis for repeated measurements was used to evaluate the bias, precision and agreement between the pulse co-oximeter and the blood gas analyser. Data are presented as mean differences and 95% limits of agreement (LoA). RESULTS: A total of 39 data pairs were obtained before in vivo adjustment. The mean invasively measured haemoglobin-SpHb difference was -2.7 g dL-1 with LoA of -4.9 to -0.5 g dL-1. After in vivo adjustment, 104 data pairs were obtained. The mean invasively measured haemoglobin-SpHb difference was -0.2 g dL-1 with LoA of -1.1 to 0.6 g dL-1. The mean SaO2-SpO2 difference was 0.86% with LoA of -0.8% to 2.5% and that between CaO2-SpOC was 0.66 mL dL-1 with LoA of -2.59 to 3.91 mL dL-1. CONCLUSIONS: Before in vivo adjustment, pulse co-oximeter derived values overestimated the spectrophotometric-based blood gas analyser haemoglobin and CaO2 values. After in vivo adjustment, the accuracy, precision and LoA markedly improved. Therefore, in vivo adjustment is recommended when using this device to monitor SpHb in anaesthetised dogs.


Assuntos
Hemoglobinas , Oximetria , Animais , Gasometria/veterinária , Cães , Hemoglobinas/análise , Oximetria/veterinária , Oxigênio , Reprodutibilidade dos Testes , Tecnologia
10.
Postgrad Med J ; 97(1145): 192-195, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32439731

RESUMO

Coronavirus disease 2019 has caused a global pandemic. The majority of patients will experience mild disease, but others will develop a severe respiratory infection that requires hospitalisation. This is causing a significant strain on health services. Patients are presenting at emergency departments with symptoms of dyspnoea, dry cough and fever with varying severity. The appropriate triaging of patients will assist in preventing health services becoming overwhelmed during the pandemic. This is assisted through clinical assessment and various imaging and laboratory investigations, including chest X-ray, blood analysis and identification of viral infection with SARS-CoV-2. Here, a succinct triaging pathway that aims to be fast, reliable and affordable is presented. The hope is that such a pathway will assist health services in appropriately combating the pandemic.


Assuntos
COVID-19/diagnóstico , Tomada de Decisão Clínica , Hospitalização , Isolamento de Pacientes , Triagem/métodos , Gasometria , COVID-19/terapia , Teste de Ácido Nucleico para COVID-19 , Teste Sorológico para COVID-19 , Gerenciamento Clínico , Escore de Alerta Precoce , Eletrocardiografia , Serviço Hospitalar de Emergência , Humanos , Equipamento de Proteção Individual , Radiografia Torácica , Medição de Risco , SARS-CoV-2 , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Triagem/economia
11.
J Neuromuscul Dis ; 8(2): 305-313, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32925087

RESUMO

BACKGROUND: Carbon dioxide tension (PCO2) monitoring during sleep, is crucial to identify respiratory failure in patients with neuromuscular disorders (NMD). Transcutaneous PCO2 monitoring is an available technique to measure PCO2. OBJECTIVES: To assess the quality level of transcutaneous blood gas measurements via SenTec monitor. METHODS: A 12-month analysis of SenTec measurements was conducted in a Belgian Centre for Home Mechanical Ventilation (HMV). Over two consecutive nights; SpO2 and PCO2 measurements, the presence of PCO2 drift and drift correction with SenTec, were reviewed and scores (0, 1, 2 for poor, medium and high level) were assigned to estimate the quality of measurements. RESULTS: Sixty-nine NMD patients met the inclusion criteria, of which 48/69 used HMV. PCO2 drift and drift correction were present in 15% and 68% of the 138 recordings, respectively. The quality level of measurements throughout night 1, scored 1.55 (0-2). The relevance of our clinical findings from SenTec scoring 1.94 (1-2); was considered highly satisfactory. HMV was ineffective in 24/48 patients. Among 12 patients with hypercapnia, 8 patients improved PCO2 between night 1 and 2. Among 12 patients with hypocapnia, PCO2 improved in 4/12 patients, who reached the range of normal PCO2 (35-47 mmHg). CONCLUSIONS: The quality of SenTec measurements was acceptable in the majority of recordings and clinical findings were deemed satisfactory in all cases. A single SenTec measurement was sufficient to determine the need for NIV. However, two SenTec registrations were insufficient to both improve NIV effectiveness in 50% of cases, and, to ensure follow-up of our interventions.


Assuntos
Monitorização Transcutânea dos Gases Sanguíneos/normas , Dióxido de Carbono/sangue , Doenças Neuromusculares/sangue , Adulto , Gasometria/métodos , Feminino , Humanos , Hipercapnia/sangue , Masculino , Pessoa de Meia-Idade , Respiração Artificial , Insuficiência Respiratória/diagnóstico , Estudos Retrospectivos
12.
Rev. bras. anal. clin ; 52(4): 337-345, 20201230. tab, ilus
Artigo em Português | LILACS | ID: biblio-1223688

RESUMO

Em humanos, o pH sanguíneo é mantido em uma faixa estreita, entre 7,35 e 7,45. Diferentes mecanismos bioquímicos, de forma harmônica, atuam para a manutenção do pH fisiológico. Múltiplos processos patológicos podem promover alterações no pH e nos gases sanguíneos, caracterizando acidose (pH <7,35) ou alcalose (pH >7,45). A ruptura da homeostasia do pH é identificada pela medição do pH, pressão parcial de dióxido de carbono (pCO2), concentração do bicarbonato (HCO3-) e, adicionalmente, com a pressão de oxigênio (pO2) em sangue arterial, processo descrito como gasometria arterial. Este artigo revisa os principais elementos associados a compreensão das alterações e tem como objetivo central apresentar uma abordagem didática e intuitiva para a caracterização destes distúrbios; e também comenta sobre ferramentais digitais destinadas a interpretações das alterações da gasometria arterial que também são abordados, como programas para computadores em ambiente web e aplicativos para telefonia móvel.


In humans, blood pH is kept in a narrow range, between 7.35 to 7.45. Different biochemical mechanisms, in a harmonic way, act to maintain the physiological pH. Multiple pathological processes can promote changes in pH and blood gases, characterizing acidosis (pH <7.35) or alkalosis (pH> 7.45). The rupture of pH homeostasis is identified by measuring pH, partial pressure of carbon dioxide (pCO2), bicarbonate concentration (HCO3 - and, in addition, with the pressure of oxygen (pO2) in arterial blood, a process described as gasometry arterial. This article reviews the main elements associated with the understanding of acid-base changes and aims to present a didactic and intuitive approach to the characterization of these disorders; and also comments on digital tools for the interpretation of alterations in arterial blood gases are also covered, such as programs for computers in a web environment and applications for mobile phone.


Assuntos
Valores de Referência , Desequilíbrio Ácido-Base , Gasometria , Software , Aplicativos Móveis
13.
Indian J Med Microbiol ; 38(3 & 4): 457-460, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33154263

RESUMO

Abnormal arterial blood gas (ABG) among patients with sepsis is an important prognostic indicator. All-cause mortality was the highest among patients with respiratory acidosis (4/9 = 44.4%), followed by those having metabolic acidosis (3/8 = 37.5%). Median length of hospital and intensive care unit stay was 15.75 days and 6.25 days for those with abnormal ABG and 11 and 3.5 days among those with normal ABG. Median health-care expenditure at the time of discharge or death of the patient was the highest in patients with respiratory acidosis ($14,473) and least in patients with normal ABG ($3,384) (average expenditure among patients with abnormal ABG was [$10,059]).


Assuntos
Gasometria/normas , Sepse/diagnóstico , Adulto , Idoso , Gasometria/economia , Estudos de Coortes , Análise Custo-Benefício , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Sepse/sangue , Sepse/complicações , Adulto Jovem
14.
Oxid Med Cell Longev ; 2020: 8822361, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33101593

RESUMO

Acute lung injury (ALI) and the subsequent acute respiratory distress syndrome remain devastating diseases with high mortality rates and poor prognoses among patients in intensive care units. The present study is aimed at investigating the role and underlying mechanisms of microRNA-31-5p (miR-31-5p) on lipopolysaccharide- (LPS-) induced ALI. Mice were pretreated with miR-31-5p agomir, antagomir, and their negative controls at indicated doses for 3 consecutive days, and then they received a single intratracheal injection of LPS (5 mg/kg) for 12 h to induce ALI. MH-S murine alveolar macrophage cell lines were cultured to further verify the role of miR-31-5p in vitro. For AMP-activated protein kinase α (AMPKα) and calcium-binding protein 39 (Cab39) inhibition, compound C or lentiviral vectors were used in vivo and in vitro. We observed an upregulation of miR-31-5p in lung tissue upon LPS injection. miR-31-5p antagomir alleviated, while miR-31-5p agomir exacerbated LPS-induced inflammation, oxidative damage, and pulmonary dysfunction in vivo and in vitro. Mechanistically, miR-31-5p antagomir activated AMPKα to exert the protective effects that were abrogated by AMPKα inhibition. Further studies revealed that Cab39 was required for AMPKα activation and pulmonary protection by miR-31-5p antagomir. We provide the evidence that endogenous miR-31-5p is a key pathogenic factor for inflammation and oxidative damage during LPS-induced ALI, which is related to Cab39-dependent inhibition of AMPKα.


Assuntos
Proteínas Quinases Ativadas por AMP/metabolismo , Lesão Pulmonar Aguda/patologia , Proteínas de Ligação ao Cálcio/metabolismo , MicroRNAs/metabolismo , Proteínas Quinases Ativadas por AMP/genética , Lesão Pulmonar Aguda/tratamento farmacológico , Animais , Antagomirs/metabolismo , Antagomirs/uso terapêutico , Gasometria , Proteínas de Ligação ao Cálcio/antagonistas & inibidores , Proteínas de Ligação ao Cálcio/genética , Modelos Animais de Doenças , Interleucina-6/genética , Interleucina-6/metabolismo , Lipopolissacarídeos/toxicidade , Macrófagos/citologia , Macrófagos/efeitos dos fármacos , Macrófagos/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , MicroRNAs/antagonistas & inibidores , MicroRNAs/genética , Estresse Oxidativo/efeitos dos fármacos , Interferência de RNA , RNA Interferente Pequeno/metabolismo , Transdução de Sinais/efeitos dos fármacos , Superóxido Dismutase/metabolismo , Regulação para Cima/efeitos dos fármacos
15.
Chest ; 158(6): 2493-2501, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32682770

RESUMO

BACKGROUND: There is an increasing demand for home mechanical ventilation (HMV) in patients with chronic respiratory insufficiency. At present, noninvasive ventilation is exclusively initiated in a clinical setting at all four centers for HMV in the Netherlands. In addition to its high societal costs and patient discomfort, commencing HMV is often delayed because of a lack of hospital bed capacity. RESEARCH QUESTION: Is HMV initiation at home, using a telemonitoring approach, noninferior to in-hospital initiation in a nationwide study? STUDY DESIGN AND METHODS: We conducted a nationwide, randomized controlled noninferiority trial, in which every HMV center recruited 24 patients (home [n = 12] vs hospital [n = 12]) with a neuromuscular disease or thoracic cage disorder, all with an indication to start HMV. Change in arterial CO2 (Paco2) over a 6-month period was considered the primary outcome, and quality of life and costs were assessed as secondary outcomes. RESULTS: A total of 96 patients were randomized, most of them diagnosed with neuromuscular disease. We found a significant improvement in Paco2 within both groups (home: from 6.1 to 5.6 kPa [P < .01]; hospital: from 6.3 to 5.6 kPa [P < .01]), with no significant differences between groups. Health-related quality of life showed significant improvement on various subscales; however, no significant differences were observed between the home and hospital groups. From a societal perspective, a cost reduction of more than €3,200 ($3,793) per patient was evident in the home group. INTERPRETATION: This nationwide, multicenter study shows that HMV initiation at home is noninferior to hospital initiation, as it shows the same improvement in gas exchange and health-related quality of life. In fact, from a patient's perspective, it might even be a more attractive approach. In addition, starting at home saves over €3,200 ($3,793) per patient over a 6-month period. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT03203577; URL: www.clinicaltrials.gov.


Assuntos
Serviços de Assistência Domiciliar , Hospitalização , Doenças Neuromusculares , Ventilação não Invasiva/métodos , Qualidade de Vida , Insuficiência Respiratória , Telemedicina/métodos , Doenças Torácicas , Gasometria/métodos , Feminino , Serviços de Assistência Domiciliar/economia , Serviços de Assistência Domiciliar/estatística & dados numéricos , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Países Baixos , Doenças Neuromusculares/sangue , Doenças Neuromusculares/complicações , Doenças Neuromusculares/psicologia , Avaliação de Processos e Resultados em Cuidados de Saúde , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/fisiopatologia , Insuficiência Respiratória/terapia , Doenças Torácicas/sangue , Doenças Torácicas/complicações , Doenças Torácicas/psicologia
16.
Arch Pathol Lab Med ; 144(10): 1209-1216, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32649215

RESUMO

CONTEXT.­: Point-of-care testing allows rapid analysis and short turnaround times. To the best of our knowledge, the present study assesses, for the first time, clinical, operative, and economic outcomes of point-of-care blood gas analysis in a nephrology department. OBJECTIVE.­: To evaluate the impact after implementing blood gas analysis in the nephrology department, considering clinical (differences in blood gas analysis results, critical results), operative (turnaround time, elapsed time between consecutive blood gas analysis, preanalytical errors), and economic (total cost per process) outcomes. DESIGN.­: A total amount of 3195 venous blood gas analyses from 688 patients of the nephrology department before and after point-of-care blood gas analyzer installation were included. Blood gas analysis results obtained by ABL90 FLEX PLUS were acquired from the laboratory information system. Statistical analyses were performed using SAS 9.3 software. RESULTS.­: During the point-of-care testing period, there was an increase in blood glucose levels and a decrease in pCO2, lactate, and sodium as well as fewer critical values (especially glucose and lactate). The turnaround time and the mean elapsed time were shorter. By the beginning of this period, the number of preanalytical errors increased; however, no statistically significant differences were found during year-long monitoring. Although there was an increase in the total number of blood gas analysis requests, the total cost per process decreased. CONCLUSIONS.­: The implementation of a point-of-care blood gas analysis in a nephrology department has a positive impact on clinical, operative, and economic terms of patient care.


Assuntos
Gasometria/economia , Nefropatias/sangue , Nefrologia/economia , Sistemas Automatizados de Assistência Junto ao Leito/economia , Testes Imediatos/economia , Humanos
17.
BMC Pediatr ; 20(1): 317, 2020 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-32593300

RESUMO

BACKGROUND: Continuous monitoring of SpO2 in the neonatal ICU is the standard of care. Changes in SpO2 exposure have been shown to markedly impact outcome, but limiting extreme episodes is an arduous task. Much more complicated than setting alarm policy, it is fraught with balancing alarm fatigue and compliance. Information on optimum strategies is limited. METHODS: This is a retrospective observational study intended to describe the relative chance of normoxemia, and risks of hypoxemia and hyperoxemia at relevant SpO2 levels in the neonatal ICU. The data, paired SpO2-PaO2 and post-menstrual age, are from a single tertiary care unit. They reflect all infants receiving supplemental oxygen and mechanical ventilation during a 3-year period. The primary measures were the chance of normoxemia (PaO2 50-80 mmHg), risks of severe hypoxemia (PaO2 ≤ 40 mmHg), and of severe hyperoxemia (PaO2 ≥ 100 mmHg) at relevant SpO2 levels. RESULTS: Neonates were categorized by postmenstrual age: < 33 (n = 155), 33-36 (n = 192) and > 36 (n = 1031) weeks. From these infants, 26,162 SpO2-PaO2 pairs were evaluated. The post-menstrual weeks (median and IQR) of the three groups were: 26 (24-28) n = 2603; 34 (33-35) n = 2501; and 38 (37-39) n = 21,058. The chance of normoxemia (65, 95%-CI 64-67%) was similar across the SpO2 range of 88-95%, and independent of PMA. The increasing risk of severe hypoxemia became marked at a SpO2 of 85% (25, 95%-CI 21-29%), and was independent of PMA. The risk of severe hyperoxemia was dependent on PMA. For infants < 33 weeks it was marked at 98% SpO2 (25, 95%-CI 18-33%), for infants 33-36 weeks at 97% SpO2 (24, 95%-CI 14-25%) and for those > 36 weeks at 96% SpO2 (20, 95%-CI 17-22%). CONCLUSIONS: The risk of hyperoxemia and hypoxemia increases exponentially as SpO2 moves towards extremes. Postmenstrual age influences the threshold at which the risk of hyperoxemia became pronounced, but not the thresholds of hypoxemia or normoxemia. The thresholds at which a marked change in the risk of hyperoxemia and hypoxemia occur can be used to guide the setting of alarm thresholds. Optimal management of neonatal oxygen saturation must take into account concerns of alarm fatigue, staffing levels, and FiO2 titration practices.


Assuntos
Unidades de Terapia Intensiva Neonatal , Oxigênio , Gasometria , Humanos , Hipóxia/diagnóstico , Hipóxia/etiologia , Lactente , Recém-Nascido , Oximetria
20.
PLoS One ; 15(4): e0230708, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32271786

RESUMO

Neonatal calf diarrhea (NCD) is a major problem to calf health worldwide, in terms of both morbidity and mortality. A five-point ordinal scale clinical assessment scoring (CAS) chart was utilized to assess calves suffering from NCD-related clinical abnormalities (acidosis and dehydration) on commercial farms. The objective of this research was to determine the predictive capability of this CAS chart against gold standard blood gas parameters, designed to assist farmers in the accurate assessment of the clinical consequences of NCD. A total of 443 diarrheic and non-diarrheic calves were enrolled in the study. The CAS chart rated a calf's health from no clinical signs to varying degrees of clinical severity on a 0 (clinically normal) to 4 (grave) scale, based on clinical indicators including calf demeanour, ear position, mobility, suckle reflex, desire-to-feed, and enophthalmos. Blood gas analysis was conducted for individual calves, consisting of pH, base excess, Na+, K+, Ca2+, Cl-, glucose, total hemoglobin, bicarbonate, anion gap, and strong ion difference. Statistical evaluation was performed by comparison of the CAS score with blood gas profiles using ordinal logistic regression and a non-parametric estimation of the Receiver Operating Characteristics (ROC). The ROC analysis indicated that the CAS chart had acceptable specificity (>95%) with low sensitivity (<60%) in differentiating clinically normal from acidotic/dehydrated cases. Assessment of individual severity classes indicated that the chart can predict and differentiate both clinically normal and advanced cases from the other severity classes (peak estimations >80%) but had reduced accuracy in differentiating mild and moderate cases (peak estimations >50%). The chart, as presented, provides a simple tool to differentiate clinically normal from calves suffering the consequences of diarrhea, but fails to accurately differentiate severity for NCD related acidosis and dehydration. Further efforts are required to enhance the sensitivity and differential diagnostic value of this type of chart.


Assuntos
Animais Recém-Nascidos , Doenças dos Bovinos/diagnóstico , Técnicas e Procedimentos Diagnósticos/veterinária , Diarreia/diagnóstico , Design de Software , Acidose/sangue , Acidose/diagnóstico , Acidose/veterinária , Animais , Gasometria/normas , Gasometria/veterinária , Bovinos , Doenças dos Bovinos/sangue , Doenças dos Bovinos/patologia , Desidratação/sangue , Desidratação/diagnóstico , Desidratação/veterinária , Técnicas e Procedimentos Diagnósticos/normas , Diarreia/sangue , Diarreia/patologia , Diarreia/veterinária , Feminino , Masculino , Valor Preditivo dos Testes , Prognóstico , Projetos de Pesquisa , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA