Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Vet Res ; 19(1): 241, 2023 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-37980491

RESUMO

BACKGROUND: The oxygen reserve index (ORi) is a real-time, continuous index measured with multi-wavelength pulse CO-oximetry technology. It estimates mild hyperoxemia in humans, which is defined as a partial pressure of oxygen (PaO2) level between 100 and 200 mmHg. The objectives of this study were to assess the correlation between ORi and PaO2, as well as to determine its ability in detecting mild hyperoxemia in dogs. METHODS: This prospective observational study enrolled 37 anaesthetised and mechanically ventilated dogs undergoing elective procedures. Simultaneous measurements of ORi and PaO2 were collected, using a multi-wavelength pulse CO-oximeter with a probe placed on the dog's tongue, and a blood gas analyser, respectively. A mixed-effects model was used to calculate the correlation (r2) between simultaneous measurements of ORi and PaO2. The trending ability of ORi to identify dependable and proportional changes of PaO2 was determined. The diagnostic performances of ORi to detect PaO2 ≥ 150 mmHg and ≥ 190 mmHg were estimated using the area under the receiver operating characteristic curve (AUROC). The effects of perfusion index (PI), haemoglobin (Hb), arterial blood pH and partial pressure of carbon dioxide (PaCO2) on AUROC for PaO2 ≥ 150 mmHg were evaluated. RESULTS: A total of 101 paired measurements of ORi and PaO2 were collected. PaO2 values ranged from 74 to 258 mmHg. A strong positive correlation (r2 = 0.52, p < 0.001) was found between ORi and PaO2. The trending ability ORi was 90.7%, with 92% sensitivity and 89% specificity in detecting decreasing PaO2. An ORi value ≥ 0.53 and ≥ 0.76 indicated a PaO2 ≥ 150 and ≥ 190 mmHg, respectively, with ≥ 82% sensitivity, ≥ 77% specificity and AUROC ≥ 0.75. The AUROC of ORi was not affected by PI, Hb, pH and PaCO2. CONCLUSIONS: In anaesthetised dogs, ORi may detect mild hyperoxaemia, although it does not replace blood gas analysis for measuring the arterial partial pressure of oxygen. ORi monitoring could be used to non-invasively assess oxygenation in dogs receiving supplemental oxygen, limiting excessive hyperoxia.


Assuntos
Oximetria , Oxigênio , Animais , Cães , Artérias , Gasometria/veterinária , Oximetria/veterinária , Oximetria/métodos , Estudos Prospectivos
2.
Res Vet Sci ; 154: 52-58, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36459719

RESUMO

To evaluate the interference of postprandial lipemia on blood gas parameters and to assess the acid-base status by the quantitative approach of the strong ion model blood samples of 15 healthy dogs were collected during fasting (0 h) and at one (1 h), three (3 h) and five (5 h) hours after the induction of lipemia with a hypercaloric diet. Total cholesterol (TC) and triglyceride (TG) levels were used to assess lipemia and these were correlated with the parameters evaluated accordingly. Anion gap decreased at 5 h without correlation with TC and TG, whereas other parameters measured by the blood gasometer did not change. In the evaluation of the acid base state, the apparent strong ion difference (SIDa) and the strong ion gap (SIG) showed a decrease at 5 h without correlation with lipemia. Lipid levels correlated with the effective strong ion difference (SIDe), the concentration of total non-volatile weak acids (Atot), albumin, phosphate, and magnesium. The SIDe increased at 1 h and at 3 h; the Atot at 1 h, 3 h, and 5 h; albumin increased at 1 h and 3 h; phosphate increased at 1 h, 3 h and 5 h; and magnesium decreased at 5 h. Though postprandial lipemia does not interfere with blood gas analysis, it can cause errors in the variables used to assess the acid-base status, which are dependent on biochemical analytes. Therefore, caution is required when interpreting electrolyte disturbances that result from the postprandial state.


Assuntos
Doenças do Cão , Hiperlipidemias , Cães , Animais , Magnésio , Equilíbrio Ácido-Base , Hiperlipidemias/veterinária , Gasometria/veterinária , Albuminas , Triglicerídeos , Doenças do Cão/diagnóstico
3.
J Vet Emerg Crit Care (San Antonio) ; 33(1): 123-127, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36468292

RESUMO

OBJECTIVE: To evaluate the variability in arterial blood gas (ABG) assessment of pulmonary function with different body positioning in dogs with suspected aspiration pneumonia. KEY FINDINGS: The median differences in alveolar-arterial gradient, Pao2 , and Paco2 values in different recumbencies were not statistically significantly different, both within patients and across the study population. No difference was noted in ABG values in the subgroups with unilateral or bilateral disease or that were more affected on the right side versus the left side. SIGNIFICANCE: This preliminary study provides data that can be used to calculate appropriate sample sizes for subsequent studies investigating the impact of recumbency on pulmonary function in patients with aspiration pneumonia.


Assuntos
Doenças do Cão , Pneumonia Aspirativa , Cães , Animais , Posicionamento do Paciente/veterinária , Pulmão , Pneumonia Aspirativa/diagnóstico , Pneumonia Aspirativa/veterinária , Gasometria/veterinária , Oxigênio , Doenças do Cão/diagnóstico
4.
Vet Anaesth Analg ; 48(3): 297-304, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33610477

RESUMO

OBJECTIVE: To compare values of haemoglobin concentration (SpHb), arterial haemoglobin saturation (SpO2) and calculated arterial oxygen content (SpOC), measured noninvasively with a pulse co-oximeter before and after in vivo adjustment (via calibration of the device using a measured haemoglobin concentration) with those measured invasively using a spectrophotometric-based blood gas analyser in anaesthetized dogs. STUDY DESIGN: Prospective observational clinical study. ANIMALS: A group of 39 adult dogs. METHODS: In all dogs after standard instrumentation, the dorsal metatarsal artery was catheterised for blood sampling, and a pulse co-oximeter probe was applied to the tongue for noninvasive measurements. Paired data for SpHb, SpO2 and SpOC from the pulse co-oximeter and haemoglobin arterial oxygen saturation (SaO2) and arterial oxygen content (CaO2) from the blood gas analyser were obtained before and after in vivo adjustment. Bland-Altman analysis for repeated measurements was used to evaluate the bias, precision and agreement between the pulse co-oximeter and the blood gas analyser. Data are presented as mean differences and 95% limits of agreement (LoA). RESULTS: A total of 39 data pairs were obtained before in vivo adjustment. The mean invasively measured haemoglobin-SpHb difference was -2.7 g dL-1 with LoA of -4.9 to -0.5 g dL-1. After in vivo adjustment, 104 data pairs were obtained. The mean invasively measured haemoglobin-SpHb difference was -0.2 g dL-1 with LoA of -1.1 to 0.6 g dL-1. The mean SaO2-SpO2 difference was 0.86% with LoA of -0.8% to 2.5% and that between CaO2-SpOC was 0.66 mL dL-1 with LoA of -2.59 to 3.91 mL dL-1. CONCLUSIONS: Before in vivo adjustment, pulse co-oximeter derived values overestimated the spectrophotometric-based blood gas analyser haemoglobin and CaO2 values. After in vivo adjustment, the accuracy, precision and LoA markedly improved. Therefore, in vivo adjustment is recommended when using this device to monitor SpHb in anaesthetised dogs.


Assuntos
Hemoglobinas , Oximetria , Animais , Gasometria/veterinária , Cães , Hemoglobinas/análise , Oximetria/veterinária , Oxigênio , Reprodutibilidade dos Testes , Tecnologia
5.
PLoS One ; 15(4): e0230708, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32271786

RESUMO

Neonatal calf diarrhea (NCD) is a major problem to calf health worldwide, in terms of both morbidity and mortality. A five-point ordinal scale clinical assessment scoring (CAS) chart was utilized to assess calves suffering from NCD-related clinical abnormalities (acidosis and dehydration) on commercial farms. The objective of this research was to determine the predictive capability of this CAS chart against gold standard blood gas parameters, designed to assist farmers in the accurate assessment of the clinical consequences of NCD. A total of 443 diarrheic and non-diarrheic calves were enrolled in the study. The CAS chart rated a calf's health from no clinical signs to varying degrees of clinical severity on a 0 (clinically normal) to 4 (grave) scale, based on clinical indicators including calf demeanour, ear position, mobility, suckle reflex, desire-to-feed, and enophthalmos. Blood gas analysis was conducted for individual calves, consisting of pH, base excess, Na+, K+, Ca2+, Cl-, glucose, total hemoglobin, bicarbonate, anion gap, and strong ion difference. Statistical evaluation was performed by comparison of the CAS score with blood gas profiles using ordinal logistic regression and a non-parametric estimation of the Receiver Operating Characteristics (ROC). The ROC analysis indicated that the CAS chart had acceptable specificity (>95%) with low sensitivity (<60%) in differentiating clinically normal from acidotic/dehydrated cases. Assessment of individual severity classes indicated that the chart can predict and differentiate both clinically normal and advanced cases from the other severity classes (peak estimations >80%) but had reduced accuracy in differentiating mild and moderate cases (peak estimations >50%). The chart, as presented, provides a simple tool to differentiate clinically normal from calves suffering the consequences of diarrhea, but fails to accurately differentiate severity for NCD related acidosis and dehydration. Further efforts are required to enhance the sensitivity and differential diagnostic value of this type of chart.


Assuntos
Animais Recém-Nascidos , Doenças dos Bovinos/diagnóstico , Técnicas e Procedimentos Diagnósticos/veterinária , Diarreia/diagnóstico , Design de Software , Acidose/sangue , Acidose/diagnóstico , Acidose/veterinária , Animais , Gasometria/normas , Gasometria/veterinária , Bovinos , Doenças dos Bovinos/sangue , Doenças dos Bovinos/patologia , Desidratação/sangue , Desidratação/diagnóstico , Desidratação/veterinária , Técnicas e Procedimentos Diagnósticos/normas , Diarreia/sangue , Diarreia/patologia , Diarreia/veterinária , Feminino , Masculino , Valor Preditivo dos Testes , Prognóstico , Projetos de Pesquisa , Índice de Gravidade de Doença
6.
PLoS One ; 14(1): e0210948, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30650142

RESUMO

Evaluating acid-base status is important for monitoring dairy herd health. In a field study, we aimed to compare the acid-base status measured by net acid-base excretion (NABE) in urine with results of venous blood analysis in clinically healthy, but possibly metabolically burdened cows in their transition period. For this, we sampled blood from the jugular vein and urine from 145 German Holstein cows within 1 to 76 days post-partum. In blood, the metabolic parameters non-esterified fatty acids (NEFA) and ß-hydroxybutyrate (BHB), as well as numerous parameters of the acid-base status were measured. The traditional approach, based on bicarbonate concentration, base excess (BE) and anion gap (AG), was compared to the strong ion approach variables, e.g. acid total (Atot), measured strong ion difference (SIDm), strong ion gap (SIG), and unmeasured anions (XA), respectively. Results of both approaches were set against the outcome of urine analysis, i.e. the NABE, base-acid ratio and pH of urine, in a cluster analysis, which provided 7 moderately stable clusters. Evaluating and interpreting these 7 clusters offered novel insights into the pathophysiology of the acid-base equilibrium in fresh post-partum dairy cows. Especially in case of subclinical acid-base disorders, the parameters of the strong ion difference theory, particularly SIDm, Atot and SIG or XA, provided more in-depth information about acid-base status than the traditional parameters BE, bicarbonate or AG in blood. The acid-base status of fresh cows with protein aberrations in blood could be differentiated in a much better way using the strong ion approach than by traditional blood gas analysis or by the measurement of urinary excretion. Therefore, the strong ion approach seems to be a suitable supplement for monitoring acid-base balance in dairy cattle.


Assuntos
Equilíbrio Ácido-Base , Bovinos/sangue , Bovinos/urina , Período Pós-Parto/sangue , Período Pós-Parto/urina , Animais , Gasometria/métodos , Gasometria/veterinária , Análise por Conglomerados , Indústria de Laticínios , Feminino , Alemanha , Concentração de Íons de Hidrogênio , Lactação/sangue , Lactação/urina , Gravidez
7.
PLoS One ; 13(8): e0202194, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30153271

RESUMO

A group of injured yellow-bellied sliders (Trachemys scripta) and river cooters (Pseudemys concinna) were evaluated for a variety of health values at presentation to the NC State Turtle Rescue Team and prior to release. An i-STAT Portable Clinical Analyzer and CG8+ cartridges were used to determine venous blood gas and biochemical values, the packed cell volume (PCV) and total protein were evaluated using hematocrit tubes and high speed centrifugation, and a differential WBC percentage was determined manually with Diff-Quick stained blood smear slides. Forty-six turtles were sampled on presentation and twenty-three of those were sampled again prior to release. Blood values were analyzed for significant differences between samples collected at presentation and prior to release, as well as differences between surviving and non-surviving turtles. Five variables were identified as significantly different between presenting and recuperated samples: pH, pCO2, Glu, % heterophils, and % eosinophils. When comparing samples between turtles that survived versus those that did not, two variables were identified as being significant prognostic indicators; lactate and PCV. Identification of these significant variables can aid in determining patient prognosis and triage therapy for injured aquatic turtles.


Assuntos
Tartarugas/sangue , Tartarugas/lesões , Animais , Análise Química do Sangue/estatística & dados numéricos , Análise Química do Sangue/veterinária , Gasometria/estatística & dados numéricos , Gasometria/veterinária , Proteínas Sanguíneas/análise , Conservação dos Recursos Naturais , Árvores de Decisões , Feminino , Água Doce , Nível de Saúde , Hematócrito/estatística & dados numéricos , Hematócrito/veterinária , Modelos Logísticos , Masculino , North Carolina , Prognóstico
8.
Reprod Domest Anim ; 52(6): 939-944, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28560819

RESUMO

The aim of this study was to develop a radiographic standard for the assessment of pulmonary fluid clearance and lung aeration in newborn calves. Caesarean-delivered mature calves (n = 9) underwent lung assessment by thoracic radiography as well as arterial and venous blood gas analysis within the first 30 min, 1, 2, 3, 6, 12 and 24 hr after birth. The results indicated that newborn calves delivered by elective Caesarean section suffered from a physiological combined respiratory and metabolic acidosis with the dominance of respiratory acidosis, and an improvement in these conditions was recorded within 24 hr after birth. Concerning the radiographic results, clear lung fields, improvement in lung expansion, air content of the lung and absence of lung opacification occurred within 24 hr of birth. Furthermore, the ventral lung quadrant showed an improvement in radiographic opacification and lung expansion earlier than the dorsal lung regions. The findings of this study support the potential role of thoracic radiography in the assessment of pulmonary fluid clearance and lung aeration in newborn calves.


Assuntos
Animais Recém-Nascidos/fisiologia , Bovinos/fisiologia , Cesárea/veterinária , Radiografia Torácica/veterinária , Acidose/veterinária , Acidose Respiratória/veterinária , Adaptação Fisiológica , Animais , Animais Recém-Nascidos/sangue , Gasometria/veterinária , Bovinos/sangue , Feminino , Pulmão/diagnóstico por imagem , Pulmão/fisiologia , Masculino , Gravidez
9.
Vet Clin North Am Exot Anim Pract ; 19(2): 379-409, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27131158

RESUMO

Rabbits have the ability to hide their signs and often present in a state of decompensatory shock. Handling can increase susceptibility to stress-induced cardiomyopathy and specific hemodynamic changes. Careful monitoring with a specific reference range is important to detect early decompensation, change the therapeutic plan in a timely manner, and assess prognostic indicators. Fluid requirements are higher in rabbits than in other small domestic mammals and can be corrected both enterally and parenterally. Critical care in rabbits can be extrapolated to many hindgut fermenters, but a specific reference range and dosage regimen need to be determined.


Assuntos
Coelhos , Choque Séptico/veterinária , Animais , Gasometria/veterinária , Determinação da Pressão Arterial/veterinária , Cuidados Críticos , Hidratação/veterinária , Oximetria/veterinária , Choque Séptico/diagnóstico , Choque Séptico/terapia , Medicina Veterinária
10.
Can Vet J ; 53(1): 63-6, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22753965

RESUMO

The purpose of this study was to assess the use of surface area derived tidal volume in anesthetized ventilated dogs (n = 71, random assignment) compared to settings by experienced personnel. There was no significant difference (P = 0.1030) between methods (p(a)CO(2) of 43.1 ± 7 mmHg and 39.8 ± 7 mmHg, respectively). Surface area derived tidal volume can achieve satisfactory ventilation.


Assuntos
Anestesia/veterinária , Cães/fisiologia , Respiração com Pressão Positiva/veterinária , Pressão Propulsora Pulmonar/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Animais , Gasometria/veterinária , Feminino , Masculino , Respiração com Pressão Positiva/métodos , Ventilação Pulmonar
11.
J Vet Intern Med ; 21(5): 1090-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17939569

RESUMO

BACKGROUND: Blood lactate concentration [LAC] is considered a useful indicator of disease severity in horses. Agreement of point-of-care (POC) lactate monitors with laboratory standards has not been established for clinically abnormal horses. HYPOTHESIS: It was hypothesized that results from a POC lactate monitor would be in agreement with a laboratory-based measurement of [LAC]. ANIMALS: The study included adult horses presented for emergency evaluation. METHODS: A prospective observational study was performed. [LAC] was measured with whole blood (AWB) and plasma (APL) by means of a POC monitor (Accutrend) and compared with results from whole blood measured by a laboratory blood gas analyzer (NOVA). RESULTS: Samples from 221 horses were used to compare the 2 lactate measurement techniques. Agreement (p +/- SE) was closest between APL and NOVA (0.97 +/- 0.01); an average observed difference of 0.15 +/- 0.89 (mean +/- SD) and 95% limits of agreement (LOA) -1.89, 1.59 also were found. Agreement was preserved and 95% LOA further decreased in horses with NOVA [LAC] of <5 mM and PCV <40%. Agreement was modest when testing whole blood samples on the POC monitor with increased 95% LOA. CONCLUSIONS AND CLINICAL IMPORTANCE: Results indicate close agreement between NOVA and the POC monitor when [LAC] was measured with plasma. Results were less consistent at higher [LAC] but sufficiently reliable to follow trends. Although whole blood may be used with the POC monitor to identify clinically important hyperlactatemia, results may be insufficiently reliable to monitor trends.


Assuntos
Serviços Médicos de Emergência/métodos , Doenças dos Cavalos/sangue , Ácido Láctico/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Animais , Gasometria/veterinária , Feminino , Hematócrito/veterinária , Cavalos , Masculino , Projetos Piloto , Estudos Prospectivos , Análise de Regressão
12.
Berl Munch Tierarztl Wochenschr ; 120(3-4): 148-55, 2007.
Artigo em Alemão | MEDLINE | ID: mdl-17416138

RESUMO

Peter Stewart criticized the traditional theory of the acid-base status by Henderson-Hasselbalch as too simple and incomplete. He developed a new model with 3 independent variables: (1) pCO2, (2) SID (strong ion difference) and (3) Atot (Acid total). In healthy and ill dogs the diagnostic usefulness of both acid-base models were compared. This study included n=58 healthy dogs and 3 clinical cases of sick dogs. The age of the healthy dogs was 5.0 (2.0-7.0) years (= median (1.-3. quartil)). The 3 clinical cases included (1) a dog with septic shock, (2) with acute renal insufficiency, and (3) with hypovolaemic shock due to gastric torsion. Venous blood was taken of all dogs and the acid-base parameters were determined within < or =30 minutes. Electrolytes and albumin were determined in blood serum and used for calculation of the Stewart variables. Limits of reference intervals (x+/-1.96 - s) were determined for the healthy dogs yielding pCO2 = 3.6-6.5 kPa, [SID3] = 33.1-50.9 mmol/l resp. [SID4] = 31.8-49.6 mmol/l and [Al = 8.5-13.1 mmol/l. In Case 1 the Henderson-Hasselbalch parameters demonstrated the presence of a strong metabolic acidosis with mild respiratory influence (pH, [HCO3-], [BE] and PCO2 at upper range of normal). Analysis of the Stewart variables [SID3] resp. [SID4] revealed an electrolyte imbalance with [Cl-] and [lactate-] as the reason for metabolic acidosis. Case 2 showed a metabolic acidosis with respiratory compensation (pH, [HCO3-], [BE] and PCO2). Analysis of the Stewart variables with [SID3] resp. [SID4 caused by [K+], [Na+] and [lactate-]demonstrated the acidotic metabolism due to a renal malfunction. Case 3 had a metabolic acidosis (pH-value in the lower range) caused by electrolyte imbalances ([SID4]. The Stewart variables allow a better understanding of the causes of acid-base-disturbances in animals with implications for successful therapy via infusion.


Assuntos
Equilíbrio Ácido-Base/fisiologia , Doenças do Cão/metabolismo , Cães/fisiologia , Acidose/metabolismo , Acidose/veterinária , Algoritmos , Animais , Bicarbonatos/metabolismo , Gasometria/veterinária , Dióxido de Carbono/metabolismo , Eletrólitos/metabolismo , Nível de Saúde , Concentração de Íons de Hidrogênio , Modelos Biológicos
13.
Am J Vet Res ; 66(4): 656-60, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15900947

RESUMO

OBJECTIVE: To evaluate the effect of dilution of blood samples with sodium heparin on blood gas, electrolyte, and lactate measurements in dogs. Sample Population-Venous blood samples collected from 6 adult dogs of various breeds. PROCEDURE: Syringes were prepared with anticoagulant via 1 of 4 techniques, and the residual volume of liquid heparin in each type of prepared syringe was determined. Blood gas values and other selected clinicopathologic variables were measured in whole blood samples after collection (baseline) and after aliquots of the samples were diluted with heparin via 1 of the 4 manual syringe techniques. By use of a tonometer, whole blood samples were adjusted to 1 of 3 oxygen concentrations (40, 100, or 600 mm Hg) and the PO2 values were measured at baseline and subsequent to the 4 heparin dilutions. RESULTS: The 4 syringe techniques resulted in 3.9%, 9.4%, 18.8%, and 34.1% dilutions of a 1-mL blood sample. Compared with baseline values, dilution of blood samples with liquid heparin significantly changed the measured values of PCO2, PO2, and base deficit and concentrations of electrolytes and lactate. Of the variables assessed, measurement of ionized calcium concentration in blood was most affected by heparin dilution. CONCLUSIONS AND CLINICAL RELEVANCE: These findings in dogs indicate that dilution of blood samples with heparin can be a source of preanalytical error in blood gas, electrolyte, and lactate measurements. Limiting dilution of blood samples with heparin to < 4% by volume via an evacuation technique of syringe heparinization is recommended.


Assuntos
Anticoagulantes/farmacologia , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/veterinária , Cães/sangue , Heparina/farmacologia , Animais , Análise Química do Sangue/métodos , Análise Química do Sangue/veterinária , Gasometria/métodos , Gasometria/veterinária , Dióxido de Carbono/sangue , Ácido Láctico/sangue , Oxigênio/sangue , Pressão Parcial
14.
Am J Vet Res ; 66(4): 661-8, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15900948

RESUMO

OBJECTIVE: To determine the hemodynamic effects of lidocaine (administered IV to achieve 6 plasma concentrations) in isoflurane-anesthetized cats. ANIMALS: 6 cats. PROCEDURE: Cats were anesthetized with isoflurane in oxygen (end-tidal isoflurane concentration set at 1.25 times the predetermined individual minimum alveolar concentration). Lidocaine was administered IV to each cat to achieve target pseudo-steady-state plasma concentrations of 0, 3, 5, 7 9, and 11 microg/mL, and isoflurane concentration was reduced to an equipotent concentration. At each plasma lidocaine concentration, cardiovascular and blood gas variables; PCV; and plasma total protein, lactate, lidocaine, and monoethylglycinexylidide concentrations were measured in cats before and during noxious stimulation. Derived variables were calculated. RESULTS: n isoflurane-anesthetized cats, heart rate, cardiac index, stroke index, right ventricular stroke work index, plasma total protein concentration, mixed-venous PO2 and hemoglobin oxygen saturation, arterial and mixed-venous bicarbonate concentrations, and oxygen delivery were significantly lower during lidocaine administration, compared with values determined without lidocaine administration. Mean arterial pressure, central venous pressure, pulmonary artery pressure, systemic and pulmonary vascular resistance indices, PCV, arterial and mixed-venous hemoglobin concentrations, plasma lactate concentration, arterial oxygen concentration, and oxygen extraction ratio were significantly higher during administration of lidocaine, compared with values determined without lidocaine administration. Noxious stimulation did not significantly affect most variables. CONCLUSIONS AND CLINICAL RELEVANCE: In isoflurane-anesthetized cats, although IV administration of lidocaine significantly decreased inhalant requirements, it appeared to be associated with greater cardiovascular depression than an equipotent dose of isoflurane alone. Administration of lidocaine to reduce isoflurane requirements is not recommended in cats.


Assuntos
Anestésicos Inalatórios/farmacologia , Anestésicos Intravenosos/farmacologia , Gatos/fisiologia , Hemodinâmica/efeitos dos fármacos , Isoflurano/farmacologia , Lidocaína/análogos & derivados , Lidocaína/farmacologia , Anestésicos Intravenosos/sangue , Animais , Gasometria/veterinária , Pressão Sanguínea/efeitos dos fármacos , Gatos/sangue , Interações Medicamentosas , Frequência Cardíaca/efeitos dos fármacos , Lidocaína/sangue , Dor/veterinária
15.
Equine Vet J ; 32(1): 59-64, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10661387

RESUMO

This study examined the ability of near infrared spectroscopy (NIRS) to noninvasively determine changes to muscle oxygenation in the resting horse. Five horses had (NIRS) performed over extremity muscle while under general anaesthesia, first with 8 min limb ischaemia, then systemic hypoxaemia for 5 min. A second group of 6 awake horses had NIRS performed over extremity muscle while being administered hypoxic gas (F(I)O2 0.10) for 5 min, and after return to steady state, limb ischaemia was induced for an additional 5 min. In the anaesthetised horses' ischaemia induced marked and significant muscle deoxygenation of haemoglobin/myoglobin (P<0.01), with corresponding arterial saturation decreasing from 98.9 to 81.9%. Hypoxaemia induced small yet significant muscle deoxygenation (P<0.01) that was 3.2% of the ischaemia deoxygenation signal, with a corresponding decrease in arterial saturation from 98.6 to 90.4%. In the awake horses muscle deoxygenation was not detectable during hypoxia despite reduction of arterial saturation from 97.8 to 86.8%, whereas ischaemia induced rapid and significant deoxygenation of muscle (P<0.05), with corresponding reduction of venous saturation from 78.4 to 75.4%. In neither group of horses was there evidence of cytochrome aa3 reduction, despite complete ischaemia for up to 8 min. NIRS changes in the resting horse muscle clearly differed between ischaemia and hypoxaemia, and can readily show muscle deoxygenation in clinically relevant hypoxaemia in the horse under anaesthesia. Further, as the deoxygenation signal induced by ischaemia was clearly detectable above a background movement artefact, NIRS application to study of muscle oxygenation in the working horse should be explored.


Assuntos
Cavalos/metabolismo , Músculo Esquelético/metabolismo , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/veterinária , Animais , Gasometria/veterinária , Complexo IV da Cadeia de Transporte de Elétrons/análise , Feminino , Membro Anterior , Hemoglobinas/análise , Membro Posterior , Hipóxia/metabolismo , Hipóxia/veterinária , Isquemia/metabolismo , Isquemia/veterinária , Masculino , Máscaras/veterinária , Mioglobina/análise , Transdutores de Pressão/veterinária
16.
Equine Vet J ; 30(5): 396-400, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9758096

RESUMO

There are limited methods of assessing pulmonary function in horses at rest. We developed clinical techniques to measure gas exchange efficiency in horses and evaluated 3 groups of horses that were 1) asymptomatic based on auscultation with rebreathing, transtracheal aspirate cytology, and thoracic radiographs (n = 6), 2) asymptomatic at rest but symptomatic with rebreathing (n = 11) and 3) symptomatic at rest (n = 9). Blood samples were obtained from the transverse facial artery and jugular vein. Maximal end-tidal CO2 tension (PETCO2) was measured by an infrared capnograph through a facemask. Alveolar O2 tension, dead space fraction (V(D)/V(T)), and physiological shunt fraction (Q(S)/Q(T)) were calculated using standard formulae. Arterial O2 tension in Group 1 horses (mean +/-s.d.103+/-3 mmHg) was significantly higher than in Group 2 or Group 3 horses. Q(S)/Q(T) in Group 1 horses (0.37+/-0.98%) was significantly lower than in Group 2 and Group 3 horses. Mean +/-s.d.V(D)/V(T) in Group 1 horses (-18.2+/-3.1) was significantly lower than Group 3 horses but not Group 2 horses.


Assuntos
Envelhecimento/fisiologia , Doenças dos Cavalos/fisiopatologia , Cavalos/fisiologia , Troca Gasosa Pulmonar , Doenças Respiratórias/veterinária , Animais , Gasometria/instrumentação , Gasometria/veterinária , Capnografia/instrumentação , Capnografia/veterinária , Dióxido de Carbono/sangue , Máscaras/veterinária , Oxigênio/sangue , Estudos Prospectivos , Valores de Referência , Doenças Respiratórias/fisiopatologia
17.
Can J Vet Res ; 61(3): 221-6, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9243003

RESUMO

Repeat determinations of the arrhythmogenic dose of epinephrine (ADE) were made over two 6 h periods on 2 separate days during halothane and isoflurane anesthesia. Each of 6 dogs underwent 4 trials (2 halothane and 2 isoflurane). During each trial, the ADE was determined at baseline, 3 and 6 h. Epinephrine was infused for 3.0 min at increasing dose rates (2.5, 5.0, 10.0 and 20.0 mg/kg/min) until the arrhythmia criterion (4 or more intermittent or continuous premature ventricular contractions) was reached. The inter-infusion interval was 20 min. There were no significant differences in the measured cardiovascular parameters (SBP, DBP, MBP, and HR), arterial blood gases, or acid-base status prior to each determination during a single trial. The cardiovascular responses to epinephrine infusion were not significantly different between inhalants or determinations. The range of the ADE determined over both trials during isoflurane anesthesia was 30.12 +/- 12.21 micrograms/kg to 50.83 +/- 9.17 micrograms/kg. The baseline ADE during Day 1 of halothane anesthesia (6.70 +/- 1.36 micrograms/kg) was significantly greater than ADE determinations at 3 (4.65 +/- 0.88 micrograms/kg) and 6 h (4.61 +/- 0.87 micrograms/kg). The reduction in the ADE over time during day 2 of halothane anesthesia was not statistically significant (P = 0.0669). These results suggest that during halothane anesthesia, the ADE is not repeatable over time, and they may influence our interpretation of the results of investigations that measure alterations in the ADE due to pharmacological manipulations without repeated control ADE determinations.


Assuntos
Adrenérgicos/administração & dosagem , Anestésicos Inalatórios , Arritmias Cardíacas/veterinária , Doenças do Cão/induzido quimicamente , Epinefrina/administração & dosagem , Halotano , Coração/efeitos dos fármacos , Isoflurano , Equilíbrio Ácido-Base , Adrenérgicos/efeitos adversos , Animais , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/fisiopatologia , Gasometria/veterinária , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Doenças do Cão/fisiopatologia , Cães , Relação Dose-Resposta a Droga , Epinefrina/efeitos adversos , Feminino , Coração/fisiologia , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Infusões Intravenosas/veterinária , Masculino , Contração Miocárdica/efeitos dos fármacos , Contração Miocárdica/fisiologia , Reprodutibilidade dos Testes , Fatores de Tempo
18.
J Vet Intern Med ; 5(5): 294-8, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1748981

RESUMO

Blood samples were collected simultaneously from the pulmonary artery, jugular vein, cephalic vein, and carotid artery in awake dogs. Blood-gas and acid-base values were measured from these blood samples in normal dogs and in dogs after production of metabolic acidosis and metabolic alkalosis. The values obtained from each of the venous sites were compared with those obtained from arterial blood to determine if venous blood from various sites accurately reflected acid-base balance and could therefore be used in the clinical patient. The results of this study demonstrated significant differences between the blood from various venous sites and the arterial site for PCO2 and pH in all acid-base states. Significant differences for standard bicarbonate (SHCO3) were found only when jugular and cephalic venous blood were compared with arterial blood in dogs with a metabolic acidosis. No significant differences were found for BE when blood from the venous sites was compared with arterial blood. The values for pH, HCO3, TCO2, BE, and SHCO3 measured on blood collected at the various venous sites were found to correlate well with those obtained from arterial blood, with a correlation coefficient of 0.99 for HCO3, TCO2, BE, and SHCO3. These correlation coefficients, together with similar values in BE at all collection sites, indicate that, in the dog with normal circulatory status, blood from any venous site will accurately reflect the acid-base status of the patient.


Assuntos
Equilíbrio Ácido-Base , Gasometria/veterinária , Coleta de Amostras Sanguíneas/veterinária , Cães/sangue , Acetazolamida/farmacologia , Equilíbrio Ácido-Base/efeitos dos fármacos , Animais , Bicarbonatos/sangue , Dióxido de Carbono/sangue , Furosemida/farmacologia , Concentração de Íons de Hidrogênio , Valores de Referência , Análise de Regressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA