Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arch Dis Child Fetal Neonatal Ed ; 109(2): 120-127, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-37173119

RESUMO

The management of low blood flow states in premature neonates is fraught with many challenges. We remain over-reliant on regimented stepwise protocols that use mean blood pressure as a threshold for intervention to guide treatment, without giving due consideration to the underlying pathophysiology. The current available evidence does not reflect the need to concentrate on the unique pathophysiology of the preterm infant and thus leads to widespread misuse of vasoactive agents that often do not provide the desired clinical effect. Therefore, understanding the underlying pathophysiological underpinnings of haemodynamic compromise may better guide choice of agent and assess physiological response to the selected intervention.


Assuntos
Hipotensão , Doenças do Recém-Nascido , Lactente , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Hipotensão/diagnóstico , Hipotensão/etiologia , Hipotensão/terapia , Hemodinâmica , Unidades de Terapia Intensiva Neonatal
2.
J Emerg Med ; 65(5): e371-e382, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37741737

RESUMO

BACKGROUND: The use of induction agents for rapid sequence intubation (RSI) has been associated with hypotension in critically ill patients. Choice of induction agent may be important and the most commonly used agents are etomidate and ketamine. OBJECTIVE: This study aimed to compare the effects of a single dose of ketamine vs. etomidate for RSI on maximum Sequential Organ Failure Assessment (SOFA) score and incidence of hypotension. METHODS: This single-center, randomized, parallel-group trial compared the use of ketamine and etomidate for RSI in critically ill adult patients in the emergency department. The study was performed under Exception from Informed Consent. The primary outcome was the maximum SOFA score within 3 days of hospitalization. RESULTS: A total of 143 patients were enrolled in the trial, 70 in the ketamine group and 73 in the etomidate group. Maximum median SOFA score for the ketamine group was 6.5 (interquartile range [IQR] 5-9) vs. 7 (IQR 5-9) for etomidate with no significant difference (-0.2; 95% CI -1.4 to 1.1; p = 0.79). The incidence of post-intubation hypotension was 28% in the ketamine group vs. 26% in the etomidate group (difference 2%; 95% CI -13% to 17%). There were no significant differences in intensive care unit outcomes. Thirty-day mortality rate for the ketamine group was 11% (8 deaths) and for the etomidate group was 21% (15 deaths), which was not statistically different. CONCLUSIONS: There were no significant differences in maximum SOFA score or post-intubation hypotension between critically ill adults receiving ketamine vs. etomidate for RSI.


Assuntos
Etomidato , Hipotensão , Ketamina , Adulto , Humanos , Etomidato/efeitos adversos , Ketamina/efeitos adversos , Escores de Disfunção Orgânica , Anestésicos Intravenosos/efeitos adversos , Indução e Intubação de Sequência Rápida , Estado Terminal/terapia , Intubação Intratraqueal , Hipotensão/etiologia
3.
CJEM ; 25(11): 902-908, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37755657

RESUMO

BACKGROUND: Accurately determining the fluid status of a patient during resuscitation in the emergency department (ED) helps guide appropriate fluid administration in the setting of undifferentiated hypotension. Our goal was to determine the diagnostic utility of point-of-care ultrasound (PoCUS) for inferior vena cava (IVC) size and collapsibility in predicting a volume overload fluid status in spontaneously breathing hypotensive ED patients. METHODS: This was a post hoc secondary analysis of the SHOC-ED data, a prospective randomized controlled trial investigating PoCUS in patients with undifferentiated hypotension. We prospectively collected data on IVC size and collapsibility for 138 patients in the PoCUS group using a standard data collection form, and independently assigned a fluid status (volume overloaded, normal, volume deplete) from a composite clinical chart review blinded to PoCUS findings. The primary outcome was the diagnostic performance of IVC characteristics on PoCUS in the detection of a volume overloaded fluid status. RESULTS: One hundred twenty-nine patients had completed determinant IVC assessment by PoCUS, with one hundred twenty-five receiving successful final fluid status determination, of which one hundred and seven were classified as volume deplete, thirteen normal, and seven volume overloaded. A receiver operating characteristic (ROC) curve was plotted using several IVC size and collapsibility categories. The best overall performance utilized the combined parameters of a dilated IVC (> 2.5 cm) with minimal collapsibility (less than 50%) which had a sensitivity of 85.7% and specificity of 86.4% with an area under the curve (AOC) of 0.92 for predicting an volume overloaded fluid status. CONCLUSION: IVC PoCUS is feasible in spontaneously breathing hypotensive adult ED patients, and demonstrates potential value as a predictor of a volume overloaded fluid status in patients with undifferentiated hypotension. IVC size may be the preferred measure.


RéSUMé: CONTEXTE: La détermination précise de l'état du liquide d'un patient pendant la réanimation au service des urgences (SU) aide à guider l'administration appropriée du liquide dans le cadre d'une hypotension indifférenciée. Notre objectif était de déterminer l'utilité diagnostique de l'échographie au point de soins (PoCUS) pour la taille de la veine cave inférieure (IVC) et l'collapsibilité dans la prédiction d'un état de liquide de surcharge volumique chez les patients souffrant d'une hypotension respiratoire spontanée. MéTHODES: Il s'agissait d'une analyse secondaire post-hoc des données SHOC-ED, un essai contrôlé randomisé prospectif examinant PoCUS chez des patients atteints d'hypotension indifférenciée. Nous avons collecté prospectivement des données sur la taille et la collapsibilité des IVC pour 138 patients du groupe PoCUS à l'aide d'un formulaire de collecte de données standard, et attribué indépendamment un état de fluide (volume surchargé, normal, épuisement du volume) à partir d'une revue de dossier clinique composite mise en aveugle aux résultats PoCUS. Le résultat principal était la performance diagnostique des caractéristiques IVC sur PoCUS dans la détection d'un état de fluide surchargé en volume. RéSULTATS: 129 patients avaient terminé l'évaluation IVC des déterminants par PoCUS, dont 125 ont reçu une détermination finale du statut hydrique, dont 107 ont été classés comme étant une diminution du volume, 13 normaux et 7 surchargés. Une courbe des caractéristiques de fonctionnement du récepteur (ROC) a été tracée en utilisant plusieurs catégories de taille et d'affaissement IVC. La meilleure performance globale a utilisé les paramètres combinés d'une IVC dilatée (> 2,5 cm) avec une collapsibilité minimale (moins de 50%) qui avait une sensibilité de 85,7% et une spécificité de 86,4% avec une zone sous la courbe (AOC) de 0,92 pour prédire un état de fluide surchargé en volume. CONCLUSION: IVC PoCUS est faisable chez les patients adultes souffrant d'une hypotension respiratoire spontanée et démontre une valeur potentielle en tant que prédicteur d'un état de liquide surchargé en volume chez les patients atteints d'hypotension indifférenciée. La taille IVC peut être la mesure préférée.


Assuntos
Insuficiência Cardíaca , Hipotensão , Adulto , Humanos , Estudos Prospectivos , Sistemas Automatizados de Assistência Junto ao Leito , Veia Cava Inferior/diagnóstico por imagem , Ultrassonografia , Hipotensão/diagnóstico por imagem , Hipotensão/etiologia
4.
J Clin Anesth ; 90: 111181, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37454554

RESUMO

STUDY OBJECTIVES: To measure the incidence of intraoperative hypotension (IOH) during surgery in ambulatory surgery centers (ASCs) and describe associated characteristics of patients and procedures. DESIGN: Retrospective analysis. SETTING: 20 ASCs. PATIENTS: 16,750 patients having non-emergent, non-cardiac surgery; ASA physical status 2 through 4. INTERVENTIONS: None. MEASUREMENTS: We assessed incidence of IOH using the definition from the Centers for Medicare & Medicaid Services (CMS) Merit-based Incentive Payment System (MIPS)-mean arterial pressure (MAP) < 65 mmHg for at least 15 cumulative minutes-and three secondary definitions: minutes of MAP <65 mmHg, area under MAP of 65 mmHg, and time-weighted average MAP <65 mmHg. MAIN RESULTS: 30.9% of ASC cases had a MAP <65 mmHg for at least 15 min. The incidence of IOH varied significantly, and was higher among younger adults (age 18-39; 36.2%), females (35.2%), and patients with ASA physical status 2 (32.8%). IOH increased with increasing surgery length, even when time-weighted, and was higher among low complexity (30.6%) than moderate complexity (28.8%) procedures, and highest among high complexity procedures (44.1%). CONCLUSIONS: There was substantial occurrence of IOH in ASCs, similar to that described in academic hospital settings in previous literature. We hypothesize that this may reflect clinician preference not to intervene in perceived healthy patients or assumptions about ability to tolerate lower blood pressures on behalf of these patients. Future research will determine whether IOH in ACSs is associated with adverse outcomes to the same extent as described in more complex hospital-based surgeries.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Hipotensão , Adulto , Feminino , Humanos , Idoso , Estados Unidos , Adolescente , Adulto Jovem , Estudos Retrospectivos , Estudos de Coortes , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Medicare , Hipotensão/etiologia , Hipotensão/complicações
5.
Am J Nephrol ; 54(3-4): 95-105, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37031677

RESUMO

INTRODUCTION: In 2017, the Centers for Medicare and Medicaid Services allowed survivors of hospitalized acute kidney injury requiring dialysis (AKI-D) who were ambulatory and still dependent on hemodialysis (HD) to receive treatment in outpatient dialysis facilities. This policy change generated the ongoing need to improve AKI-D care in the outpatient setting. METHODS: Quality improvement study in adult patients admitted to an outpatient HD unit with the diagnosis of AKI-D. We developed a protocol to manage these patients that included: (a) multidisciplinary evaluations; (b) personalized 3-tier HD prescription for dose/ultrafiltration rate and frequency; (c) weekly assessment of kidney recovery; and (d) patient empowerment. Patient- and protocol-specific characteristics were described. We analyzed hourly HD data and protocol adherence, and relevant hemodynamic data were compared according to HD-free survival at 90 days. RESULTS: A total of 457.3 h of HD from 9 patients under the AKI-D protocol were interrogated. Three out of 9 patients were alive and liberated from HD within the first 90 days of outpatient HD. Overall protocol adherence was 53.8% and did not differ by HD-free survival (54.5% vs. 53.7% in those that recovered vs. not). Protocol adherence was associated with fewer intradialytic hypotension events (peak to nadir blood pressure, p < 0.01), while intradialytic hypotension (pre- to post-blood pressure) occurred more frequently in patients who did not recover kidney function (p = 0.009). CONCLUSION: We demonstrated the feasibility of implementing a management protocol for AKI-D patients in an outpatient dialysis facility. We found that fewer episodes of intradialytic hypotension occurred when the outpatient HD management was adherent to the protocol. The feasibility of this protocol should be confirmed in other facilities, and importantly, efficacy testing to evaluate its impact on AKI-D outpatient care is necessary.


Assuntos
Injúria Renal Aguda , Hipotensão , Diálise Renal , Adulto , Idoso , Humanos , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , Hipotensão/epidemiologia , Hipotensão/etiologia , Hipotensão/terapia , Medicare , Pacientes Ambulatoriais , Melhoria de Qualidade , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Estados Unidos/epidemiologia
6.
Braz J Anesthesiol ; 73(4): 385-392, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35430190

RESUMO

BACKGROUND: Post-spinal anesthesia hypotension is of common occurrence, and it hampers tissue perfusion. Several preoperative factors determine patient susceptibility to hypotension. This study aimed to assess the effectiveness of the Inferior Vena Cava Collapsibility Index (IVCCI) for predicting intraoperative hypotension. METHODS: One hundred twenty-nine adult patients who were scheduled for elective surgical procedures after administration of spinal (intrathecal) anesthesia were included in the study. Ultrasound evaluation of the Inferior Vena Cava (IVC) was done in the preoperative area, and the patients were shifted to the Operating Room (OR) for spinal anesthesia. An independent observer recorded the change in blood pressure after spinal anesthesia inside the OR. RESULTS: Twenty-five patients developed hypotension (19.37%). Baseline systolic blood pressure and mean blood pressures were statistically higher in those patients who developed hypotension (p = 0.001). The logistic regression analysis for IVCCI and the incidence of hypotension showed r2 of 0.025. Receiver Operating Characteristic (ROC) curve analysis demonstrated the Area Under the Curve (AUC) of 0.467 (95% Confidence Interval, 0.338 to 0.597; p = 0.615). CONCLUSIONS: Preoperative evaluation of IVCCI is not a good predictor for the occurrence of hypotension after spinal anesthesia.


Assuntos
Raquianestesia , Hipotensão , Adulto , Humanos , Raquianestesia/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia , Hipotensão/epidemiologia , Hipotensão/etiologia
7.
Braz. J. Anesth. (Impr.) ; 73(4): 385-392, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1447614

RESUMO

Abstract Background Post-spinal anesthesia hypotension is of common occurrence, and it hampers tissue perfusion. Several preoperative factors determine patient susceptibility to hypotension. This study aimed to assess the effectiveness of the Inferior Vena Cava Collapsibility Index (IVCCI) for predicting intraoperative hypotension. Methods One hundred twenty-nine adult patients who were scheduled for elective surgical procedures after administration of spinal (intrathecal) anesthesia were included in the study. Ultrasound evaluation of the Inferior Vena Cava (IVC) was done in the preoperative area, and the patients were shifted to the Operating Room (OR) for spinal anesthesia. An independent observer recorded the change in blood pressure after spinal anesthesia inside the OR. Results Twenty-five patients developed hypotension (19.37%). Baseline systolic blood pressure and mean blood pressures were statistically higher in those patients who developed hypotension (p= 0.001). The logistic regression analysis for IVCCI and the incidence of hypotension showed r2 of 0.025. Receiver Operating Characteristic (ROC) curve analysis demonstrated the Area Under the Curve (AUC) of 0.467 (95% Confidence Interval, 0.338 to 0.597; p= 0.615). Conclusions Preoperative evaluation of IVCCI is not a good predictor for the occurrence of hypotension after spinal anesthesia.


Assuntos
Humanos , Hipotensão/etiologia , Hipotensão/epidemiologia , Raquianestesia/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia
8.
Neurol India ; 70(4): 1568-1574, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36076660

RESUMO

Background: Hypotension is one of the most common complications following induction of general anesthesia. Preemptive diagnosis and correcting the hypovolemic status can reduce the incidence of post-induction hypotension. However, an association between preoperative volume status and severity of post-induction hypotension has not been established in neurosurgical patients. We hypothesized that preoperative ultrasonographic assessment of intravascular volume status can be used to predict post-induction hypotension in neurosurgical patients. Our study objective was to establish the relationship between pre-induction maximum inferior vena cava (IVC) diameter, collapsibility index (CI), and post-induction reduction in mean arterial blood pressure in neurosurgical patients. Materials and Methods: A prospective observational study was conducted including 100 patients undergoing elective intracranial surgeries. IVC assessment was done before induction of general anesthesia. Receiver operating characteristic (ROC) curve analysis was used to determine the cutoff values of maximum and minimum IVC diameter (IVCDmax and IVCDmin, respectively) and CI for prediction of hypotension. Results: Post-induction hypotension was observed in 41% patients. Patients with small IVCDmax and higher CI% developed hypotension. The areas under the ROC curve (AUCs) were 0.64 (0.53-0.75) for IVCDmax and 0.69 (0.59-0.80) for IVCDmin. The optimal cutoff values were1.38 cm for IVCDmax and 0.94 cm for IVCDmin. The AUC for CI was 0.65 (0.54-0.77) and the optimal cutoff value was 37.5%. Conclusion: Pre-induction IVC assessment with ultrasound is a reliable method to predict post-induction hypotension resulting from hypovolemia in neurosurgical patients.


Assuntos
Hipotensão , Veia Cava Inferior , Humanos , Hipotensão/diagnóstico por imagem , Hipotensão/etiologia , Hipovolemia/diagnóstico por imagem , Hipovolemia/etiologia , Reprodutibilidade dos Testes , Ultrassonografia , Veia Cava Inferior/diagnóstico por imagem
9.
Curr Opin Nephrol Hypertens ; 31(6): 553-559, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36172854

RESUMO

PURPOSE OF REVIEW: Patients with chronic kidney disease characteristically exhibit microcirculatory dysfunction, in combination with vascular damage. Hemodialysis superimposes additional circulatory stress to the microvasculature (repetitive ischemic insults/cumulative damage) resulting in high mortality. Intradialytic monitoring and hemodialysis delivery is currently limited to macrovascular/systemic assessment and detection of intradialytic systemic hypotension. Monitoring of the microcirculation has the potential to provide valuable information on hemodialysis-induced circulatory stress likely to result in end-organ ischemia (with/without systemic hypotension) generating an opportunity to intervene before tissue injury occurs. RECENT FINDINGS: Various noninvasive technologies have been used assessing the microcirculation in hemodialysis patients at rest. Some technologies have also been applied during hemodialysis studying the effects of treatment on the microcirculation. Despite the approach used, results are consistent. Hemodialysis patients have impaired microcirculations with treatment adding additional stress to inadequately regulated vascular beds. Utility/practicality/clinical relevance vary significantly between methodologies. SUMMARY: Intradialytic monitoring of the microcirculation can provide additional insights into a patient's individual response to treatment. However, this valuable perspective has not been adopted into clinical practice. A microcirculatory view could provide a window of opportunity to enable a precision medicine approach to treatment delivery improving current woefully poor subjective and objective clinical outcomes.


Assuntos
Hipotensão , Insuficiência Renal Crônica , Humanos , Hipotensão/diagnóstico , Hipotensão/etiologia , Microcirculação , Diálise Renal/efeitos adversos , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia
10.
Scand J Gastroenterol ; 57(9): 1105-1111, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35403537

RESUMO

OBJECTIVE: Most endoscopists routinely perform moderate or deep sedation for esophagogastroduodenoscopy (EGD). Considering that there is no consensus on the optimal sedation depth and it varies from country to country, our study aims to compare the effectiveness, cost and safety of these two sedation methods in the Chinese population. METHODS: This quasi-experimental study included a total of 556 eligible patients from July 2020 to June 2021, and they entered the moderate sedation group or deep sedation group based on their choices. Baseline information, scores of Patient Satisfaction with Sedation Instrument (PSSI) and Clinician Satisfaction with Sedation Instrument (CSSI), examination time, sedation time, recovery time, expenses before medicare reimbursement, hypoxaemia and hypotension were compared between the two groups. Propensity Score Matching (PSM) analysis was conducted to balance the confounding factors. RESULTS: After PSM, 470 patients were involved in the analysis, with 235 for each group. The moderate sedation was clearly superior to the deep sedation group in terms of PSSI score (98.00 ± 0.94 vs. 97.29 ± 1.26), CSSI score (98.00 ± 0.78 vs. 97.67 ± 1.30), sedation time (11.90 ± 2.04 min vs. 13.21 ± 2.75 min), recovery time (25.40 ± 3.77 min vs. 28.0 ± 4.85 min), expenses (433.04 ± 0.00 Yuan vs. 789.85 ± 0.21 Yuan), with all p < .001. Examination time was not significantly different between the two groups (p = .124). In addition, the moderate sedation group had a lower occurrence rate of hypoxaemia (0.36% vs. 3.27%, p = .010) and hypotension (17.44% vs. 44.00%, p < .001) compared to the deep sedation group. CONCLUSIONS: Moderate sedation presented better effectiveness and safety and lower cost, and thereby it should be recommended as a widely used sedation method in clinical practice in China. Trial registration: This trial was registered on http://www.chictr.org.cn/index.aspx (ChiCTR2000038050).


Assuntos
Sedação Profunda , Hipotensão , Propofol , Idoso , Sedação Consciente/métodos , Análise Custo-Benefício , Sedação Profunda/efeitos adversos , Sedação Profunda/métodos , Endoscopia do Sistema Digestório/efeitos adversos , Endoscopia do Sistema Digestório/métodos , Humanos , Hipnóticos e Sedativos/efeitos adversos , Hipotensão/etiologia , Hipóxia/etiologia , Medicare , Estados Unidos
11.
Int J Obstet Anesth ; 49: 103245, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35012810

RESUMO

INTRODUCTION: Assessment of adequacy of spinal anaesthesia, prior to obstetric surgery is extremely important but can be problematic because currently available clinical assessment methods are indirect and subjective. As the sympathectomy associated with spinal anaesthesia is known to cause vasodilation and heat redistribution, we sought to assess whether spinal anaesthesia led to significant and consistent cutaneous temperature changes as measured by infrared thermography. METHODS: Following ethics committee approval, this observational study was conducted in a tertiary level obstetric centre. Participants included women undergoing elective caesarean section under spinal anaesthesia. Following consent, a Flir T540 infrared camera captured thermographic images over the feet, patella, buttock, iliac crests, xiphisternum and axilla. Temperature was measured prior to spinal needle insertion (T0) and following clinical assessment when the block was deemed adequate. RESULTS: Thirty patients were included. Baseline temperature varied considerable by site. Spinal anaesthesia altered skin temperature in all areas of interest: right and left hallux (mean of differences (MD) +4.0°C and 5.2°C respectively, P <0.0001), right and left plantar (MD +6.1°C and 6.8°C respectively, P <0.0001), patella (MD -0.33°C, P=0.0445), buttock (MD -0.5°C, P=0.009), iliac crest (MD -0.7°C, P=0.0004), xiphisternum (MD -0.95°C, P <0.0001) and axilla (MD -0.71°C, P=0.0002). CONCLUSIONS: Following spinal anaesthesia thermographic imaging identified different patterns of skin temperature changes, with pronounced temperature increases measured in the feet and cooling of a lesser amplitude in the thoracic and lumbar dermatomes. Infrared thermography has the potential to provide objective measurement of sympathectomy.


Assuntos
Anestesia Obstétrica , Raquianestesia , Hipotensão , Anestesia Obstétrica/métodos , Raquianestesia/métodos , Cesárea/métodos , Feminino , Humanos , Hipotensão/etiologia , Gravidez , Temperatura
12.
Ren Fail ; 43(1): 1137-1145, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34261422

RESUMO

BACKGROUND AND AIMS: Early detection of acute kidney injury (AKI) is crucial for the prognosis of patients after liver transplantation (LT). This passage aims to analyze the perioperative clinical markers of AKI after LT and establish predictive models based on clinical variables for early detection of AKI after LT. METHODS: We prospectively collected 109 patients with LT, and compared the differences of perioperative clinical markers between the AKI group and non-AKI group. The scoring system and decision tree model were established through the risk factors. Another 163 patients who underwent LT in the same center from 2017 to 2018 were retrospectively collected to verify the models. RESULTS: In multiple comparisons of risk factors of post-LT AKI, pre-operative factors were excluded automatically, intraoperative and post-operative factors including operating time, intraoperative hypotension time, post-operative infection, the peak of post-operative AST, and post-operative shock were the independent risk factors for post-LT AKI. The scoring system established with the risk factors has good predictive power (AUC = 0.755) in the validation cohort. The decision tree also shows that post-operative shock was the most important marker, followed by post-operative infection. CONCLUSION: Five intraoperative and post-operative factors are independently associated with post-LT AKI rather than pre-operative factors, which indicates that operation technique and post-operative management may more important for the prevention of post-LT AKI. The scoring system and decision tree model could complement each other, and provide quantitative and intuitive prediction tools for clinical practice of early detection of post-LT AKI.


Assuntos
Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Árvores de Decisões , Transplante de Fígado/efeitos adversos , Adulto , Feminino , Humanos , Hipotensão/etiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Medição de Risco/métodos , Fatores de Risco
13.
Anesth Analg ; 133(4): 852-859, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33346986

RESUMO

Focused cardiac ultrasound (FoCUS) has become a valuable tool to assess unexplained hypotension in critically ill patients. Due to increasing availability of transthoracic echocardiography (TTE) equipment in the operating room, there is a widespread interest in its usefulness for intraoperative diagnosis of hypotension as an alternative to transesophageal echocardiography (TEE). The objective of this systematic review is to evaluate the utility of intraoperative FoCUS to assess patients experiencing unexplained hypotension while undergoing noncardiac surgery. We performed a systematic literature search of multiple publication databases for studies that evaluated the utility of intraoperative FoCUS for assessment and management of unexplained hypotension in patients undergoing noncardiac surgery, including retro- and prospective clinical studies. A summary of the study findings, study quality, and assessment of level of evidence is presented. We identified 2227 unique articles from the literature search, of which 27 were potentially relevant, and 9 were included in this review. The number of patients pooled from these studies was 255, of whom 228 had intraoperative diagnoses with the aid of intraoperative FoCUS. The level of evidence of all studies included was very low according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) guidelines. This systematic review has demonstrated that FoCUS may be a useful, noninvasive method to differentiate causes of intraoperative hypotension and guide correcting interventions, although the quality of evidence is very low. Further prospective high-quality studies are needed to investigate whether intraoperative FoCUS has a diagnostic utility that is associated with improved outcomes.


Assuntos
Pressão Sanguínea , Ecocardiografia , Hipotensão/diagnóstico por imagem , Cuidados Intraoperatórios , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Diagnóstico Diferencial , Humanos , Hipotensão/etiologia , Hipotensão/fisiopatologia , Hipotensão/terapia , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco
14.
BMC Nephrol ; 21(1): 194, 2020 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-32448178

RESUMO

BACKGROUND: Accurate assessment of volume status to direct dialysis remains a clinical challenge. Despite current attempts at volume-directed dialysis, inadequate dialysis and intradialytic hypotension (IDH) are common occurrences. Peripheral venous waveform analysis has recently been developed as a method to accurately determine intravascular volume status through algorithmic quantification of changes in the waveform that occur at different volume states. A noninvasive method to capture peripheral venous signals is described (Non-Invasive Venous waveform Analysis, NIVA). The objective of this proof-of-concept study was to characterize changes in NIVA signal with dialysis. We hypothesized that there would be a change in signal after dialysis and that the rate of intradialytic change in signal would be predictive of IDH. METHODS: Fifty subjects undergoing inpatient hemodialysis were enrolled. A 10-mm piezoelectric sensor was secured to the middle volar aspect of the wrist on the extremity opposite to the access site. Signals were obtained fifteen minutes before, throughout, and up to fifteen minutes after hemodialysis. Waveforms were analyzed after a fast Fourier transformation and identification of the frequencies corresponding to the cardiac rate, with a NIVA value generated based on the weighted powers of these frequencies. RESULTS: Adequate quality (signal to noise ratio > 20) signals pre- and post- dialysis were obtained in 38 patients (76%). NIVA values were significantly lower at the end of dialysis compared to pre-dialysis levels (1.203 vs 0.868, p < 0.05, n = 38). Only 16 patients had adequate signals for analysis throughout dialysis, but in this small cohort the rate of change in NIVA value was predictive of IDH with a sensitivity of 80% and specificity of 100%. CONCLUSIONS: This observational, proof-of-concept study using a NIVA prototype device suggests that NIVA represents a novel and non-invasive technique that with further development and improvements in signal quality may provide static and continuous measures of volume status to assist with volume directed dialysis and prevent intradialytic hypotension.


Assuntos
Volume Sanguíneo , Hipotensão/etiologia , Monitorização Fisiológica/métodos , Diálise Renal/efeitos adversos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo/fisiologia , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Estudo de Prova de Conceito , Sensibilidade e Especificidade , Razão Sinal-Ruído
15.
Nephrol Ther ; 15(6): 439-447, 2019 Nov.
Artigo em Francês | MEDLINE | ID: mdl-31585841

RESUMO

Many apheresis techniques can be performed in a blood-bank facility or a hemodialysis (HD) facility. However, it makes sense to perform apheresis in a hemodialysis facility as apheresis involves extra-corporeal circuits and because HD can be performed at the same time as apheresis (tandem procedure). Apheresis techniques comprise therapeutic plasma exchange, double-filtration plasmapheresis, and its derivative (rheopheresis and LDL-apheresis), and immunoadsorption (specific and semi-specific). We have setup an apheresis platform in our hospital that fulfills health recommendations. This process has involved financial investment and significant human resources, and has enabled us to network with different specialties (neurology, hematology, vascular medicine). We have setup protocols according to the type of pathology to be treated by apheresis, and to monitor clinical and biological data for each apheresis session. The main side effects of apheresis are a fall in blood pressure when a session is initiated, an increase in fluid overload, hypocalcemia, and the loss of some essential plasmatic factors. However, these side-effects are easily identified and can be properly managed in real time. Within two-years, we have performed 1845 apheresis sessions (134 patients). Of these, 66 received apheresis before and/or after kidney transplantation for ABO and/or HLA incompatibility (desensitization), for humoral rejection, or in the setting of relapsing focal-segmental glomerulosclerosis. Our patients' outcomes have been similar to those reported in the literature. The other 68 patients had various conditions. Because our program is now well-established, we are currently forming a specialist center to train physicians and nurses in the various apheresis techniques/procedures.


Assuntos
Remoção de Componentes Sanguíneos , Unidades Hospitalares de Hemodiálise/organização & administração , Remoção de Componentes Sanguíneos/efeitos adversos , Remoção de Componentes Sanguíneos/instrumentação , Remoção de Componentes Sanguíneos/métodos , Remoção de Componentes Sanguíneos/estatística & dados numéricos , Ácido Cítrico/administração & dosagem , Ácido Cítrico/efeitos adversos , Grupos Diagnósticos Relacionados , Glucose/administração & dosagem , Glucose/efeitos adversos , Glucose/análogos & derivados , Necessidades e Demandas de Serviços de Saúde , Hospitais Universitários/organização & administração , Humanos , Hipocalcemia/etiologia , Hipotensão/etiologia , Transplante de Rim , Equipe de Assistência ao Paciente , Utilização de Procedimentos e Técnicas , Diálise Renal , Estudos Retrospectivos
16.
J Anesth ; 33(5): 612-619, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31451896

RESUMO

PURPOSE: Severe hypotension caused by anesthetic administration for anesthesia induction, which might cause ischemic stroke, myocardial injury, acute kidney injury and postoperative mortality, should be prevented. Anesthesiologists are familiar with ultrasound examination of the internal jugular vein (IJV). This study aimed to clarify whether ultrasonographic IJV evaluation just before induction could predict the occurrence of such hypotension. METHODS: Adult patients undergoing surgery under general anesthesia were enrolled after excluding patients with cardiovascular disease or ASA-PS ≥ III. Ultrasonographic IJV images were recorded in both the supine and 10° Trendelenburg positions immediately before induction. Using these images, IJV area (IJV-A), diameter and change rate with posture were measured. Hypotension during induction was defined as mean BP < 60 mmHg or > 30% decrease from baseline. RESULTS: Hypotension during induction was observed in 37 of 82 patients. IJV-A in the Trendelenburg position was 2.02 ± 0.86 and 1.72 ± 0.68 in the hypotensive and non-hypotensive groups, respectively (P = 0.08). Logistic regression analysis performed using age, use of calcium antagonists, angiotensin converting enzyme inhibitors/angiotensin receptor blockers, baseline mean BP and IJV-A in the Trendelenburg position as variables showed that IJV-A in the Trendelenburg position was an independent predictor of hypotension, with an adjusted odds ratio of 3.11 (95% CI 1.07-9.03, P = 0.04). Area under the curve was 0.595 (95% CI 0.469-0.722) for IJV-A in the Trendelenburg position. CONCLUSION: IJV-A in the Trendelenburg position was an independent predictor of hypotension during induction. Further study is required to examine the diagnostic accuracy of IJV-A as a predictor for hypotension during induction.


Assuntos
Anestesia Geral/métodos , Hipotensão/etiologia , Veias Jugulares/diagnóstico por imagem , Ultrassonografia , Adulto , Idoso , Inibidores da Enzima Conversora de Angiotensina/administração & dosagem , Feminino , Decúbito Inclinado com Rebaixamento da Cabeça , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Período Pós-Operatório , Postura , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos
17.
J Trauma Acute Care Surg ; 87(5): 1077-1081, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31205211

RESUMO

BACKGROUND: The Prehospital Air Medical Plasma (PAMPer) trial demonstrated a 30-day survival benefit among hypotensive trauma patients treated with prehospital plasma during air medical transport. We characterized resources, costs and feasibility of air medical prehospital plasma program implementation. METHODS: We performed a secondary analysis using data derived from the recent PAMPer trial. Intervention patients received thawed plasma (5-day shelf life). Unused plasma units were recycled back to blood bank affiliates, when possible. Distribution method and capability of recycling varied across sites. We determined the status of plasma units deployed, utilized, wasted, and returned. We inventoried thawed plasma use and annualized costs for distribution and recovery. RESULTS: The PAMPer trial screened 7,275 patients and 5,103 plasma units were deployed across 22 air medical bases during a 42-month period. Only 368 (7.2%) units of this total thawed plasma pool were provided to plasma randomized PAMPer patients. Of the total plasma pool, 3,716 (72.8%) units of plasma were returned to the blood bank with the potential for transfusion prior to expiration and 1,019 (20.0%) thawed plasma units were deemed wasted for this analysis. The estimated average annual cost of implementation of a thawed plasma program per air medical base at an average courier distance would be between US $24,343 and US $30,077, depending on the ability to recycle plasma and distance of courier delivery required. CONCLUSION: A prehospital plasma program utilizing thawed plasma is resource intensive. Plasma waste can be minimized depending on trauma center and blood bank specific logistics. Implementation of a thawed plasma program can occur with financial cost. Products with a longer shelf life, such as liquid plasma or freeze-dried plasma, may provide a more cost-effective prehospital product relative to thawed plasma. LEVEL OF EVIDENCE: Therapeutic, level III.


Assuntos
Resgate Aéreo/organização & administração , Transfusão de Componentes Sanguíneos/métodos , Hipotensão/terapia , Plasma , Ressuscitação/métodos , Ferimentos e Lesões/terapia , Resgate Aéreo/economia , Transfusão de Componentes Sanguíneos/economia , Análise Custo-Benefício , Serviços Médicos de Emergência/economia , Serviços Médicos de Emergência/organização & administração , Estudos de Viabilidade , Implementação de Plano de Saúde/economia , Implementação de Plano de Saúde/organização & administração , Humanos , Hipotensão/etiologia , Hipotensão/mortalidade , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Ressuscitação/economia , Análise de Sobrevida , Centros de Traumatologia/economia , Centros de Traumatologia/organização & administração , Ferimentos e Lesões/complicações , Ferimentos e Lesões/mortalidade
18.
Pulm Med ; 2019: 4347852, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31210988

RESUMO

BACKGROUND AND OBJECTIVES: The ideal type of sedation for endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is not known. Two previous studies comparing the diagnostic yield between moderate sedation (MS) and deep sedation/general anesthesia (DS/GA) had provided conflicting results with one study clearly favoring the latter. No study had addressed cost. This is concerning for pulmonologists without routine access to anesthesia services. Our objective was to assess the impact of MS and Monitored Anesthesia Care (sedation administered and monitored by an anesthesiologist) on the outcomes and cost of EBUS-TBNA. MATERIALS AND METHODS: We performed a retrospective review of prospectively collected data on consecutive EBUS-TBNA performed under two different types of sedation in a single academic center. A diagnostic TBNA was defined as an aspirate yielding any specific diagnosis or if subsequent surgery or follow-up of nondiagnostic/normal aspirates showed no pathology. Current Medicare time-based allowances were used for professional charges calculation. RESULTS: There was no difference observed between MS and MAC in regards of the diagnostic yield (92.9% versus 91.9%), procedure duration, number, location, and size of lymph node (LN) sampled, but there were more passes per LN with MAC. The average charges were 74.30 USD for MS and 319.91 for MAC. There were more hypotensive and desaturations episodes with MAC but none required escalation of care. CONCLUSIONS: When performed under MS, EBUS-TBNA has similar diagnostic yield as under MAC but may be associated with less side effects. The difference in sedation cost is modest; however, an additional 245$ for each EBUS done under MAC would have significant cost implications on the health system. These findings are of critical importance for bronchoscopists without routine access to anesthesia services and for optimization of healthcare cost and resource utilization.


Assuntos
Anestesia Geral , Sedação Consciente , Sedação Profunda , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/economia , Feminino , Humanos , Hipotensão/etiologia , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
19.
J Med Econ ; 22(4): 383-389, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30698059

RESUMO

OBJECTIVE: This economic analysis extends upon a recent epidemiological study to estimate the association between hypotension control and hospital costs for septic patients in US intensive care units (ICUs). METHODS: A Monte Carlo simulation decision analytic model was developed that accounted for the probability of complications-acute kidney injury and mortality-in septic ICU patients and the cost of each health outcome from the hospital perspective. Probabilities of complications were calculated based on observational data from 110 US hospitals for septic ICU patients (n = 8,782) with various levels of hypotension exposure as measured by mean arterial pressure (MAP, units: mmHg). Costs for acute kidney injury (AKI) and mortality were derived from published literature. Each simulation calculated mean hospital cost reduction and 95% confidence intervals based on 10,000 trials. RESULTS: In the base-case analysis hospital costs for a hypothetical "control" cohort (MAP of 65 mmHg) were $699 less per hospitalization (95% CI: $342-$1,116) relative to a "case" cohort (MAP of 60 mmHg). In the most extreme case considered (45 mmHg vs 65 mmHg), the associated cost reduction was $4,450 (95% CI: $2,020-$7,581). More than 99% of the simulated trials resulted in cost reductions. A conservative institution-level analysis for a hypothetical hospital (which assumes no benefit for increasing MAP above 65 mmHg) estimated a cost decline of $417 for a 5 mmHg increase in MAP per ICU septic patient. These results are applicable to the US only. CONCLUSIONS: Hypotension control (via MAP increases) for patients with sepsis in the ICU is associated with lower hospitalization cost.


Assuntos
Custos Hospitalares/estatística & dados numéricos , Hipotensão/economia , Unidades de Terapia Intensiva/economia , Sepse/economia , Injúria Renal Aguda/economia , Injúria Renal Aguda/etiologia , Pressão Arterial , Custos e Análise de Custo , Feminino , Humanos , Hipotensão/tratamento farmacológico , Hipotensão/etiologia , Masculino , Método de Monte Carlo , Sepse/complicações , Sepse/mortalidade
20.
Am Surg ; 84(9): 1450-1454, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30268174

RESUMO

Gunshot wounds (GSW) are becoming increasingly prevalent in urban settings. GSW to the trunk mandate full trauma activation and immediate surgeon response because of the high likelihood of operative intervention. Extremity GSW proximal to the knee/elbow also require full trauma activation based on American College of Surgeons Committee on trauma standards. However, whether isolated extremity GSW require frequent operative intervention is unclear. We evaluated GSW at our Level I trauma center from January 2012 to December 2016. Demographic data and injury patterns were abstracted from the trauma registry and charts. The number of GSW increased yearly but the age, gender, Injury Severity Score and injury pattern did not change (P = ns, not shown). There were 504 GSW that included an extremity and 194 (38%) involved multiple body regions. There were 310 GSW (62%) isolated to an extremity and 176 were proximal to the elbow/knee. If proximal GSW had an Emergency Department systolic blood pressure <90 mm Hg, 53 per cent underwent vascular repair, 12 per cent had soft tissue repair, and 29 per cent required no operation. If proximal GSW had an Emergency Department blood pressure >90 mm Hg, 57 per cent underwent orthopedic repair, 22 per cent required no surgery, and only 13 per cent required vascular repair (P < 0.01). In the absence of other criteria for full trauma activation such as shock, the need for the immediate presence of a general surgeon to perform emergency surgery for a GSW isolated to the extremity is low.


Assuntos
Traumatismos do Braço/cirurgia , Traumatismos da Perna/cirurgia , Traumatismo Múltiplo/cirurgia , Seleção de Pacientes , Centros de Traumatologia , Ferimentos por Arma de Fogo/cirurgia , Adolescente , Adulto , Traumatismos do Braço/complicações , Traumatismos do Braço/diagnóstico , Feminino , Necessidades e Demandas de Serviços de Saúde , Humanos , Hipotensão/diagnóstico , Hipotensão/etiologia , Escala de Gravidade do Ferimento , Traumatismos da Perna/complicações , Traumatismos da Perna/diagnóstico , Masculino , Pessoa de Meia-Idade , Traumatismo Múltiplo/complicações , Traumatismo Múltiplo/diagnóstico , Estudos Retrospectivos , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/diagnóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA