Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Vet Radiol Ultrasound ; 64(5): 864-872, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37549962

RESUMO

Magnetic resonance imaging is the gold standard for diagnosing intervertebral disc (IVD) degeneration in dogs. However, published methods for quantifying severity or progression of IVD degeneration are currently limited. Mapping MRI sequences are used in humans for quantifying IVD degeneration but have rarely been applied in dogs. The objective of this prospective, method comparison study was to evaluate variable flip angle T1 mapping and multiecho T2 and T2* mapping as methods for quantifying canine lumbar IVD degeneration in twenty canine patients without clinical signs of spinal disease. Ventral and dorsal lumbar IVD widths were measured on radiographs, and lumbar IVDs were assigned a qualitative Pfirrmann grade based on standard T2-weighted sequences. T1, T2, and T2* relaxation times of the nucleus pulposus (NP) were measured on corresponding maps using manual-drawn ROIs. Strong intra- and interrater agreements were found (P < 0.01) for NP relaxation times. Radiographic IVD widths and T1, T2, and T2* mapping NP relaxation times were negatively correlated with Pfirrmann grading (P < 0.01). Significant differences in T1 NP relaxation times were found between Pfirrmann grade I and the other grades (P < 0.01). Significant differences in T2 and T2* NP relaxation times were found between grade I and the other grades and between grades II and III (P < 0.01). Findings indicated that T1, T2, and T2* MRI mapping sequences are feasible in dogs. Measured NP relaxation times were repeatable and decreased when Pfirrmann grades increased. These methods may be useful for quantifying the effects of regenerative treatment interventions in future longitudinal studies.


Assuntos
Doenças do Cão , Degeneração do Disco Intervertebral , Disco Intervertebral , Humanos , Cães , Animais , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/veterinária , Estudos Prospectivos , Imageamento por Ressonância Magnética/veterinária , Imageamento por Ressonância Magnética/métodos , Região Lombossacral , Interpretação de Imagem Assistida por Computador , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Disco Intervertebral/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia
2.
J Equine Vet Sci ; 126: 104492, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37072071

RESUMO

Acquisition of magnetic resonance images of the equine limb is still sometimes conducted under general anaesthesia. Despite low-field systems allow the use of standard anaesthetic equipment, possible interferences of the extensive electronic componentry of advanced anaesthetic machines on image quality is unknown. This prospective, blinded, cadaver study investigated the effects of seven standardised conditions (Tafonius positioned as in clinical cases, Tafonius on the boundaries of the controlled area, anaesthetic monitoring only, Mallard anaesthetic machine, Bird ventilator, complete electronic silence in the room (negative control), source of electronic interference [positive control]) on image quality through the acquisition of 78 sequences using a 0.31T equine MRI scanner. Images were graded with a 4-point scoring system, where 1 denoted absence of artefacts and 4 major artefacts requiring repetition in a clinical setting. A lack of STIR fat suppression was commonly reported (16/26). Ordinal logistic regression showed no statistically significant differences in image quality between the negative control and either the non-Tafonius or the Tafonius groups (P = 0.535 and P = 0.881, respectively), and with the use of Tafonius compared to the other anaesthetic machines (P = 0.578). The only statistically significant differences in scores were observed between the positive control and the non-Tafonius (P = 0.006) and the Tafonius groups (P = 0.017). Our findings suggest that anaesthetic machines and monitoring do not appear to affect MRI scan quality and support the use of Tafonius during acquisition of images with a 0.31T MRI system in a clinical context.


Assuntos
Anestesia , Anestésicos , Doenças dos Cavalos , Cavalos , Animais , Artefatos , Estudos Prospectivos , Imageamento por Ressonância Magnética/veterinária , Cadáver , Anestesia/veterinária
3.
J Comp Pathol ; 196: 26-40, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36008042

RESUMO

There is general awareness of artificial selection and its potential implications on the health and welfare of animals. Despite growing popularity and increasing numbers of reptile breeds of atypical colour and pattern variants, only a few studies have investigated the appearance and causes of diseases associated with colour morphs. Ball pythons (Python regius) are among the most frequently bred reptiles and breeders have selected for a multitude of different colour and pattern morphs. Among those colour variants, the spider morph of the ball python is frequently associated with wobble syndrome. The aim of this study was to determine whether a morphological variant can be found and associated with the clinical occurrence of wobble syndrome in spider ball pythons, using computed tomography and magnetic resonance imaging as in-vivo diagnostic methods. Data from five spider and three wild type ball pythons was assessed and evaluated comparatively. We were able to identify distinctive structural differences in inner ear morphology in spider ball pythons, which were highly likely related to wobble syndrome. To our knowledge, this is the first report of these anomalies and provides a basis for further anatomical and genetic studies and discussion of the implications for animal welfare in reptile breeding.


Assuntos
Boidae , Aranhas , Animais , Imageamento por Ressonância Magnética/veterinária , Tomografia Computadorizada por Raios X
4.
Vet Comp Oncol ; 20(2): 404-415, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34792828

RESUMO

Standardized veterinary neuroimaging response assessment methods for brain tumours are lacking. Consequently, a response assessment in veterinary neuro-oncology (RAVNO) system which uses the sum product of orthogonal lesion diameters on 1-image section with the largest tumour area, has recently been proposed. In this retrospective study, 22 pre-treatment magnetic resonance imaging (MRI) studies from 18 dogs and four cats with suspected intracranial neoplasia were compared by a single observer to 32 post-treatment MRIs using the RAVNO system and two volumetric methods based on tumour margin or area delineation with HOROS and 3D Slicer software, respectively. Intra-observer variability was low, with no statistically significant differences in agreement index between methods (mean AI ± SD, 0.91 ± 0.06 for RAVNO; 0.86 ± 0.08 for HOROS; and 0.91 ± 0.05 for 3D slicer), indicating good reproducibility. Response assessments consisting of complete or partial responses, and stable or progressive disease, agreed in 23 out of 32 (72%) MRI evaluations using the three methods. The RAVNO system failed to identify changes in mass burden detected with volumetric methods in six cases. 3D Slicer differed from the other two methods in three cases involving cysts or necrotic tissue as it allowed for more accurate exclusion of these structures. The volumetric response assessment methods were more precise in determining changes in absolute tumour burden than RAVNO but were more time-consuming to use. Based on observed agreement between methods, low intra-observer variability and decreased time constraint, RAVNO might be a suitable response assessment method for the clinical setting.


Assuntos
Neoplasias Encefálicas , Doenças do Gato/diagnóstico por imagem , Doenças do Cão , Imageamento por Ressonância Magnética , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/veterinária , Gatos , Doenças do Cão/diagnóstico por imagem , Cães , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/veterinária , Neuroimagem/veterinária , Reprodutibilidade dos Testes , Estudos Retrospectivos
5.
Vet Radiol Ultrasound ; 62(6): 687-696, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34510632

RESUMO

Fat infiltration of skeletal muscle (myosteatosis) is a characteristic of reduced muscle quality. Objectives of this retrospective, observer agreement, methods comparison, cross-sectional study were to compare epaxial myosteatosis of dogs with surgically confirmed intervertebral disc extrusion (IVDE) using a visual semi-quantitative method and quantitative 2-point Dixon fat-water chemical-shift separation MRI method. Thoracolumbar MRI studies of 86 dogs were reviewed. Assessed locations were the site of extrusion and the adjacent intervertebral disc space immediately cranial. A visual fat score (VFS) was assigned to fat infiltration of the epaxial muscles. Quantitative assessment of fat infiltration was determined by calculating a muscle-fat fraction (MFF). There was moderate agreement between the two reviewers for VFS assessment (weighted Kappa 0.60, 95%CI 0.53-0.66) with moderate to strong correlation between scoring methods (P ≤ .001). Both VFS (P = .023, P = .02) and MFF (P = .041, P = .043) were significantly correlated with neurologic grade at presentation for the erector spinae muscle group at both sites. Higher VFS in the multifidus muscle increased the odds of a successful outcome when assessed at the extrusion site (odds ratio and 95%CI 4.3 (1.02-78.7), P = .0461). In summary, the visual and Dixon method of epaxial muscle-fat assessment are feasible in dogs with IVDE with moderate to strong correlation. Increased VFS of myosteatosis in the multifidus muscle at the extrusion site significantly increased the odds of a successful outcome. Further studies are indicated to assess the utility of myosteatosis as an MRI imaging biomarker in the preoperative imaging assessment of dogs with IVDE.


Assuntos
Disco Intervertebral , Imageamento por Ressonância Magnética , Animais , Estudos Transversais , Cães , Disco Intervertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/veterinária , Estudos Retrospectivos
6.
Anat Histol Embryol ; 50(5): 839-848, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34318942

RESUMO

In humans and pets, magnetic resonance imaging (MRI) provides important adjunctive anatomic information about the thyroid and its adjacent structures. To the best of our knowledge, however, no studies have been reported regarding the use of MRI for thyroid evaluation in horses. The aim of this study was to obtain qualitative and quantitative parameters of healthy thyroid gland in adult horses by MRI. Eleven horses were submitted to thyroid MRI evaluation. The healthy thyroid of these animals was ensured by normal examinations performed before (free thyroxine and ultrasound) and after (cytology) to MRI. It was concluded that the dorsal spin-echo T1-weighted, fast spin-echo T2-weighted, sagittal STIR and a three-dimensional T1-weighted gradient echo were the sequences that best characterized the thyroid lobes. Qualitatively, there was a significant variation in the elliptical format of some lobes considering the sagittal plane, which oscillated between rounded and flattened conformation. Excellent reproducibility of the quantitative thyroid parameters obtained was verified. The thyroid gland total volume mean of observers was 14.31 cm3 (±0.69). In relation with comparisons between quantitative parameters of left and right lobes, only differences regarding their respective lengths were observed. Thus, we can infer that the difference in some thyroid lobes format can be explained by the significant variation identified between left and right lobes lengths.


Assuntos
Imageamento por Ressonância Magnética , Glândula Tireoide , Animais , Cavalos , Imageamento por Ressonância Magnética/veterinária , Reprodutibilidade dos Testes , Glândula Tireoide/diagnóstico por imagem
7.
Vet Radiol Ultrasound ; 62(5): 610-620, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34148276

RESUMO

Lesions of the deep digital flexor tendon (DDFT) are a cause for foot lameness in horses. Positron emission tomography (PET) could provide valuable information regarding the metabolic activity of these lesions. The aims of this exploratory, prospective, methods comparison study were to assess the ability of 18 fluorine-fluorodeoxyglucose (18 F-FDG) PET to detect DDFT lesions and to compare the PET findings with CT and MRI findings. Eight horses with lameness due to pain localized to the front feet were included. Both front limbs of all horses were imaged with 18 F-FDG PET, noncontrast CT, and arterial contrast-enhanced CT; 11 limbs were also assessed using MRI. Two observers graded independently 18 F-FDG PET, noncontrast CT, arterial contrast CT, T1-weighted (T1-w) MRI, and T2-weighted (T2-w)/STIR MRI. Maximal standardized uptake values were measured. Lesions were found in seven of 16 DDFT on PET, 12 of 16 DDFT on noncontrast CT, six of 15 DDFT on arterial contrast CT, eight of 11 DDFT on T1-w MRI, and six of 11 DDFT on T2-w/STIR MRI. Positron emission tomography was in better agreement with arterial contrast CT (Kappa-weighted 0.40) and T2-w/STIR MRI (0.35) than with noncontrast CT (0.28) and T1-w MRI (0.20). Maximal standardized uptake values of lesions ranged from 1.9 to 4.6 with a median of 3.1. Chronic lesions with scar tissues identified on noncontrast CT or T1-w MRI did not have increased 18 F-FDG uptake. These results demonstrated that 18 F-FDG PET agreed more closely with modalities previously used to detect active tendon lesions, i.e. arterial contrast CT and T2-w/STIR MRI. 18 Fluorine-fluorodeoxyglucose PET can be used to identify metabolically active DDFT lesions in horses.


Assuntos
Doenças dos Cavalos , Tendinopatia , Animais , Flúor , Fluordesoxiglucose F18 , Doenças dos Cavalos/diagnóstico por imagem , Cavalos , Imageamento por Ressonância Magnética/veterinária , Tomografia por Emissão de Pósitrons/veterinária , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tendinopatia/veterinária , Tomografia Computadorizada por Raios X
8.
Vet J ; 271: 105653, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33840484

RESUMO

Ten healthy Beagle dogs were used to compare selected echocardiographic parameters of right ventricular (RV) systolic function with high field cardiac magnetic resonance imaging (MRI). All dogs underwent complete transthoracic echocardiography before and during anesthesia, as well as cardiac MRI with determination of morphology-based ejection fraction, and phase contrast angiography-derived stroke volume. A correlation analysis was carried out between echocardiographic and MRI parameters. The values of fractional area change, tricuspid annular plane systolic excursion, tissue Doppler imaging derived peak velocity of the isovolumic contraction wave and systolic wave of the lateral tricuspid valve annulus showed lower values under general anesthesia. Of all echocardiographic parameters of RV systolic function, only fractional area change (r = 0.671, P = 0.034) and tissue Doppler imaging derived peak velocity of the systolic wave of the lateral tricuspid valve annulus (r = 0.768; P = 0.01), showed a significant correlation with MRI derived stroke volume. None of the echocardiographic parameters correlated with MRI derived ejection fraction. When evaluating the RV echocardiographically, fractional area change and peak velocity of the systolic wave of the lateral tricuspid valve annulus appear to be the most reliable predictors of RV systolic function when compared to MRI under anesthesia.


Assuntos
Ecocardiografia/veterinária , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/veterinária , Sístole/fisiologia , Função Ventricular Direita/fisiologia , Anestesia/veterinária , Animais , Cães , Feminino , Masculino
9.
Am J Vet Res ; 81(12): 930-939, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33251841

RESUMO

OBJECTIVE: To compare measurements of left ventricular volume and function derived from 2-D transthoracic echocardiography (2DE), transesophageal echocardiography (TEE), and the ultrasound velocity dilution cardiac output method (UDCO) with those derived from cardiac MRI (cMRI) in healthy neonatal foals. ANIMALS: 6 healthy 1-week-old Standardbred foals. PROCEDURES: Foals were anesthetized and underwent 2DE, TEE, and cMRI; UDCO was performed simultaneously with 2DE. Images acquired by 2DE included the right parasternal 4-chamber (R4CH), left apical 4- and 2-chamber (biplane), and right parasternal short-axis M-mode (M-mode) views. The longitudinal 4-chamber view was obtained by TEE. Measurements assessed included left ventricular end-diastolic volume (LVEDV), end-systolic volume (LVESV), ejection fraction, stroke volume (LVSV), cardiac output (CO), and cardiac index (CI). Bland-Altman analyses were used to compare measurements derived from biplane, R4CH, and M-mode images and UDCO with cMRI-derived measurements. Repeatability of measurements calculated by 3 independent reviewers was assessed by the intraclass correlation coefficient. RESULTS: Compared with cMRI, all 2DE and TEE modalities underestimated LVEDV and LVESV and overestimated ejection fraction, CO, and CI. The LVSV was underestimated by the biplane, R4CH, and TEE modalities and overestimated by UDCO and M-mode methods. However, the R4CH-derived LVSV, CO, and CI were clinically comparable to cMRI-derived measures. Repeatability was good to excellent for measures derived from the biplane, R4CH, M-mode, UDCO, and cMRI methods and poor for TEE-derived measures. CONCLUSIONS AND CLINICAL RELEVANCE: All assessed modalities yielded clinically acceptable measurements of LVEDV, LVESV, and function, but those measurements should not be used interchangeably when monitoring patient progress.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Animais , Ecocardiografia Transesofagiana/veterinária , Ventrículos do Coração/diagnóstico por imagem , Cavalos , Imageamento por Ressonância Magnética/veterinária , Volume Sistólico , Função Ventricular Esquerda
10.
Am J Vet Res ; 80(11): 1012-1019, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31644342

RESUMO

OBJECTIVE: To evaluate the use of transrectal ultrasonography (TRUS) for the assessment of prostatic tumors in dogs and to compare results for TRUS with results for other imaging modalities. ANIMALS: 10 client-owned male dogs. PROCEDURES: Client-owned dogs identified with prostatic carcinoma were enrolled. Fluoroscopy, transabdominal ultrasonography (TAUS), TRUS, and MRI were performed on all dogs. Tumor measurements, urethral penetration (identification of abnormal tissue within the urethral lumen), and tumor extension into the urinary tract were recorded for all imaging modalities. Agreement between results for MRI (considered the criterion-referenced standard) and results for other modalities were compared. RESULTS: Median body weight of the 10 dogs was 26.3 kg (range, 9.4 to 49.5 kg). No complications were encountered during or after TRUS. Significant moderate to good agreements (intraclass correlation coefficients, 0.60 to 0.86) among TAUS, TRUS, fluoroscopy, and MRI were identified for tumor length and height. Assessments of urethral penetration and tumor extension into the bladder with TRUS did not differ significantly from those made with MRI and were superior in terms of absolute agreement with MRI when compared with those for TAUS. CONCLUSIONS AND CLINICAL RELEVANCE: TRUS was successfully and safely used to evaluate prostatic carcinoma in dogs. There was moderate to good agreement with MRI results for tumor height and length measurements, and TRUS was found to be superior to TAUS for some assessments. Transrectal ultrasonography can be considered an adjunctive imaging modality for the performance of prostatic interventional procedures or assessment of response to treatment.


Assuntos
Doenças do Cão/diagnóstico por imagem , Neoplasias da Próstata/veterinária , Ultrassonografia/veterinária , Animais , Cães , Imageamento por Ressonância Magnética/veterinária , Masculino , Neoplasias da Próstata/diagnóstico por imagem
11.
J Vet Cardiol ; 24: 28-35, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31405552

RESUMO

In human medicine, non-contrast cardiac magnetic resonance imaging (CMRI) is routinely used to assess the cardiovascular system. In this study, using non-contrast CMRI, we provide a thorough description of the normal appearance of the intrathoracic cardiovascular structures in one healthy cat using a magnet operating at a field of 1.5-Tesla. The CMRI protocol was based on the use of fast spin-echo double inversion recovery and steady-state free precession pulse sequences in oblique short-axis, vertical long-axis, and horizontal long-axis imaging planes. After imaging the feline heart, four cadaver cats injected with latex substance into their arterial and venous systems were sectioned to facilitate interpretation of the intrathoracic cardiovascular structures to the corresponding CMRI. The fast spin-echo double inversion recovery images showed the best evaluation of gross intrathoracic anatomy, giving excellent contrast of the myocardium and vessels walls as they appeared with intermediate signal intensity compared to the lumen that appeared with low signal intensity. By contrast, steady-state free precession images showed details of the heart cavities and vascular lumen due to the high signal intensity of fast-flowing blood. The results of this study provide some anatomic detail for the heart and associated vessels as seen by non-contrast CMRI in the domestic cat.


Assuntos
Sistema Cardiovascular/anatomia & histologia , Gatos/anatomia & histologia , Animais , Sistema Cardiovascular/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/veterinária , Masculino , Valores de Referência
12.
Am J Vet Res ; 80(6): 595-600, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31140851

RESUMO

OBJECTIVE: To evaluate repeatability and reproducibility of muscle condition score (MCS) in dogs with various degrees of muscle loss; to compare MCS, muscle ultrasonographic measurements, and quantitative magnetic resonance (QMR) measurements; and to identify cutoff values for ultrasonographic measurements of muscle that can be used to identify dogs with cachexia and sarcopenia. ANIMALS: 40 dogs of various age, body condition score (BCS), and MCS. PROCEDURES: A prospective cross-sectional study was conducted. Body weight, BCS, QMR measurements, thoracic radiographic measurements, and muscle ultrasonographic measurements were assessed once in each dog. The MCS for each dog was assessed 3 separate times by 4 separate raters. RESULTS: For the MCS, overall κ for interrater agreement was 0.50 and overall κ for intrarater agreement ranged from 0.59 to 0.77. For both interrater and intrarater agreement, κ coefficients were higher for dogs with normal muscle mass and severe muscle loss and lower for dogs with mild and moderate muscle loss. The MCS was significantly correlated with age (r = -0.62), vertebral epaxial muscle score (VEMS; r = 0.71), forelimb epaxial muscle score (FLEMS; r = 0.58), and BCS (r = 0.73), and VEMS was significantly correlated (r = 0.84) with FLEMS. Cutoff values for identification of mild muscle loss determined by use of VEMS and FLEMS were 1.124 and 1.666, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: MCS had substantial repeatability and moderate reproducibility for assessment of muscle mass in dogs. Prospective studies of MCS, VEMS, and FLEMS for assessment of muscle mass in dogs are warranted.


Assuntos
Doenças do Cão/patologia , Doenças Musculares/veterinária , Animais , Peso Corporal , Estudos Transversais , Doenças do Cão/diagnóstico por imagem , Cães , Feminino , Imageamento por Ressonância Magnética/veterinária , Masculino , Doenças Musculares/diagnóstico por imagem , Doenças Musculares/patologia , Estudos Prospectivos , Radiografia Torácica/veterinária , Reprodutibilidade dos Testes , Ultrassonografia/veterinária
13.
J Vet Cardiol ; 21: 79-92, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30797448

RESUMO

INTRODUCTION: The objective of the study was to evaluate the accuracy of two- and three-dimensional (2D, 3D) transthoracic echocardiography (TTE), 2D transesophageal echocardiography, and computed tomography angiography (CTA) compared with cardiac magnetic resonance imaging (CMR) in normal dogs and to assess repeatability of 2D and 3D TTE for the assessment of left ventricular (LV) and left atrial (LA) dimensions. ANIMALS: The study was performed on six healthy dogs. MATERIALS AND METHODS: Transthoracic echocardiography, transesophageal echocardiography, CTA, and CMR were performed on each dog. Right ventricular (RV) and LV volumes (in systole and diastole), ejection fraction (EF), and LA and right atrial (RA) volumes were assessed. Repeatability and intrarater and interrater measurements of variability were quantified by average coefficient of variation (CV) for 2D and 3D TTE. RESULTS: No clinically relevant differences in LV volume were detected between CMR and all modalities. Importantly, 3D TTE had the lowest CV (6.45%), correlated with (rs = 0.62, p = 0.01), and had the highest overlap in distribution with CMR (OVL >80%). Left ventricular EF and LA size via CTA compared best with CMR and RV and RA volumes were best estimated by 3D TTE. Assessment of LV and LA volumes via 3D TTE had moderate repeatability (15-21%) compared with LV M-mode measurements and 2D LA-to-aortic ratio (<10%), respectively. For LV size, interrater CV for 3D TTE (19.4%) was lower than 2D TTE (23.1%). CONCLUSIONS: Measurements of LV, RV, and RA volumes via 3D TTE and LA volume and LV EF assessed by CTA compared best with CMR. Three-dimensional echocardiography had lower interrater and intrarater CV compared with 2D TTE.


Assuntos
Cães/anatomia & histologia , Ecocardiografia Tridimensional/veterinária , Ecocardiografia Transesofagiana/veterinária , Ecocardiografia/veterinária , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/veterinária , Tomografia Computadorizada por Raios X/veterinária , Animais , Feminino , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Reprodutibilidade dos Testes
14.
Vet Comp Orthop Traumatol ; 31(4): 261-272, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29859514

RESUMO

OBJECTIVES: To determine the effectiveness of magnetic resonance imaging (MRI) in the evaluation of anatomical stifle structures with respect to implant positioning after tibial plateau levelling osteotomy (TPLO) using a titanium plate. METHODS: Selected sagittal and dorsal sequences of pre- and postoperative MRI (1.0 T scanner) of 13 paired (n = 26) sound cadaveric stifle joints were evaluated. The effect of susceptibility artifact on adjacent anatomical stifle structures was graded from 0 to 5. The impact of implant positioning regarding assessment score was calculated using Spearman's rank correlation coefficient. RESULTS: Sagittal turbo spin echo (TSE)-acquired images enabled interpretation of most soft tissue, osseous and cartilage structures without detrimental effect of susceptibility artifact distortions. In T2-weighted TSE images, the cranial cruciate ligament and caudal horn of the medial meniscus could be evaluated, independent of implant position, without any susceptibility artifact in all specimens. T2-weighted fast field echo, water selective, balanced fast field echo and short tau inversion recovery were most markedly affected by susceptibility artifact. CLINICAL SIGNIFICANCE: In selected TSE sequences, MRI allows evaluation of critical intra-articular structures after titanium TPLO plate implantation. Further investigations with confirmed stifle pathologies in dogs are required, to evaluate the accuracy of MRI after TPLO in clinical cases in this context.


Assuntos
Cães , Imageamento por Ressonância Magnética/veterinária , Osteotomia/veterinária , Joelho de Quadrúpedes/diagnóstico por imagem , Animais , Ligamento Cruzado Anterior , Imageamento por Ressonância Magnética/métodos , Próteses e Implantes/veterinária , Tíbia , Titânio
15.
Vet Comp Orthop Traumatol ; 30(6): 391-397, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29202501

RESUMO

Objectives This study aims to assess and compare the T2 relaxation times for articular cartilage of normal canine stifle joints in four regions by T2 mapping using a 1.5-T magnetic resonance imaging (MRI). Methods In vivo prospective study: 20 hindlimbs (left and right) from 10 normal healthy beagle dogs (n = 20). The region of interest (ROI) was subdivided into medial and lateral condyles of femoral cartilage (MF and LF, respectively) and medial and lateral condyles of tibial cartilage (MT and LT, respectively). The T2 relaxation times were assessed in regions where the cartilage thickness was greater than 0.5 mm. Results The median maximum cartilage thickness (mm) of the four ROI were 0.7 (range: 0.9-0.6), 0.6 (range: 0.7-0.5), 0.7 (range: 0.9-0.5) and 0.6 (range: 0.8-0.5) at MF, LF, MT and LT, respectively. The errors in the measurement (%) of the four ROI were 64.3 (range: 50.0-75.0), 75.0 (range: 64.3-90.0), 64.3 (range: 20.0-90.0) and 75.0 (range: 56.3-90.0) at MF, LF, MT and LT, respectively. The median T2 relaxation times (ms) for the articular cartilage of the four ROI were 70.2 (range: 57.9-87.9), 57.5 (range: 46.8-66.9), 65.0 (range: 52.0-92.0) and 57.0 (range: 49.0-66.2) at MF, LF, MT and LT, respectively. The inter-observer correlation coefficient (ICC, 2.1) for the T2 relaxation times of MF was 0.644. Clinical Significance This study offers useful information on T2 relaxation times for articular cartilage of the stifle joint using a 1.5-T MRI in normal dogs.


Assuntos
Cartilagem Articular/fisiologia , Cães/fisiologia , Imageamento por Ressonância Magnética/veterinária , Joelho de Quadrúpedes/fisiologia , Animais , Cartilagem Articular/anatomia & histologia , Cartilagem Articular/diagnóstico por imagem , Cães/anatomia & histologia , Feminino , Masculino , Estudos Prospectivos , Joelho de Quadrúpedes/anatomia & histologia , Joelho de Quadrúpedes/diagnóstico por imagem , Tempo
16.
Equine Vet J ; 49(6): 821-828, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28470772

RESUMO

BACKGROUND: Noninvasive imaging tools are needed to screen foal femoropatellar joints to detect subclinical osteochondrosis lesions due to focal failure of endochondral ossification to enhance early management to optimise intrinsic healing events. Recently investigations employing 3T susceptibility-weighted magnetic resonance imaging (3T SWI MRI) and CT have demonstrated their capacity for early osteochondrosis diagnosis, but these technologies are not practical for field screening. We postulate that ultrasonography is a valuable field tool for the detection of subclinical osteochondrosis lesions. OBJECTIVES: The goals were to 1) describe the ultrasonographic features of the femoral trochlea of healthy and osteochondrosis-predisposed neonatal foals, 2) validate the capacity of ultrasound to assess cartilage canal vascular archictecture and the ossification front and 3) evaluate field feasibility in a pilot study. STUDY DESIGN: Experimental study. METHODS: Ultrasonographic evaluation of osteochondrosis predisposed (n = 10) and control (n = 6) femoral trochleas was performed ex vivo and compared with site-matched histological sections and 3T SWI MRI. The articular and epiphyseal cartilage thickness, ossification front indentation and cartilage canal vascular archictecture were assessed at each ROI. Femoral trochleae of foals (n = 3) aged ≈ 1, 3 and 6 months were also evaluated with ultrasonography in field. RESULTS: Ultrasonographic measurements strongly correlated with the histological measurements. There was no difference in the cartilage thickness or ossification front indentation between control and osteochondrosis-predisposed specimens. The cartilage canal vascular archictecture on ultrasonograms corresponded with the vessel pattern observed on site matched histology and 3T SWI MRI. MAIN LIMITATIONS: The number of specimens for study was limited and no early osteochondrosis lesions were present within the predilected group, but a field study is now underway. CONCLUSION: Ultrasonographic examination of the femoral trochlea permitted accurate evaluation of cartilage thickness, cartilage canal vascular archictecture and ossification front indentation in young foals and is a promising, practical tool for screening subclinical osteochondrosis and monitoring and managing lesions at important clinical sites.


Assuntos
Fêmur/diagnóstico por imagem , Lâmina de Crescimento/diagnóstico por imagem , Doenças dos Cavalos/diagnóstico por imagem , Osteocondrose/veterinária , Animais , Animais Recém-Nascidos , Feminino , Cavalos , Imageamento por Ressonância Magnética/veterinária , Masculino , Osteocondrose/diagnóstico por imagem , Ultrassonografia/normas , Ultrassonografia/veterinária
17.
J Vet Intern Med ; 31(3): 842-848, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28440586

RESUMO

BACKGROUND: Prognostic tools to predict early postoperative motor function recovery (MFR) after thoracolumbar intervertebral disk herniation (IVDH) in paraplegic dogs represent an opportunity to timely implement novel therapies that could shorten recovery times and diminish permanent neurological dysfunctions. HYPOTHESIS: Fractional anisotropy (FA) values obtained using diffusion tensor imaging have a higher prognostic value than a lesion extension ratio in T2-weighted images (T2W-LER) and clinical assessment of deep pain perception (DPP) for MFR. ANIMALS: Thirty-five paraplegic dogs with diagnosis of acute or subacute thoracolumbar IVDH. METHODS: Prospective, descriptive observational study. At admission, absence or presence of DPP, T2W-LER, and FA values was evaluated. MFR was assessed within 4 weeks after decompressive surgery. Values of T2W-LER and FA of dogs with and without MFR were compared using t-tests. All 3 methods were evaluated for their sensitivity and specificity as a prognostic factor. RESULTS: No differences were found between groups regarding T2W-LER. FA values differed statistically when measured caudally of lesion epicenter being higher in dogs without MFR compared to dogs with MFR (P = .023). Logistic regression analysis revealed significance in FA values measured caudally of the lesion epicenter (P = .033, area under the curve = 0.72). Using a cutoff value of FA = 0.660, the technique had a sensitivity of 80% and a specificity of 55%. Evaluation of DPP had a sensitivity of 73.3% and specificity of 75% (P = .007). CONCLUSIONS AND CLINICAL IMPORTANCE: Evaluation of DPP showed a similar sensitivity and a better specificity predicting early MFR than quantitative magnetic resonance imaging.


Assuntos
Dor Aguda/veterinária , Doenças do Cão/diagnóstico por imagem , Deslocamento do Disco Intervertebral/veterinária , Paraplegia/veterinária , Dor Aguda/diagnóstico por imagem , Animais , Doenças do Cão/diagnóstico , Cães/cirurgia , Feminino , Deslocamento do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/cirurgia , Imageamento por Ressonância Magnética/veterinária , Masculino , Paraplegia/diagnóstico , Paraplegia/cirurgia , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/veterinária , Prognóstico , Estudos Prospectivos , Recuperação de Função Fisiológica , Caminhada
18.
J Am Vet Med Assoc ; 248(9): 1013-21, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27074609

RESUMO

OBJECTIVE To evaluate interobserver agreement for features used in presumptive diagnosis of acute noncompressive nucleus pulposus extrusion (ANNPE) or ischemic myelopathy by MRI, compare findings on postcontrast T1-weighted (T1W) MRI sequences with fat saturation (FS) for the 2 conditions, and determine whether length and directional patterns of hyperintensity of the intramedullary spinal cord on T2-weighted (T2W) fast spin echo (FSE) MRI sequences differ between dogs with these diseases. DESIGN Retrospective, observational study. ANIMALS 20 dogs with clinical signs compatible with ANNPE (n = 14) or ischemic myelopathy (6). PROCEDURES 3 observers evaluated MRI data (including T2W FSE, T2W single-shot FSE, and T1W FS sequences) for dogs with a presumptive diagnosis of ischemic myelopathy or ANNPE. Interobserver agreement for variables of interest including presumptive diagnosis was assessed by κ statistic calculations. Associations between diagnosis and variables of interest were assessed with Fisher exact or Cochran-Mantel-Haenszel tests. RESULTS Perfect interobserver agreement (κ = 1 for all comparisons) was found for the presumptive diagnosis of ischemic myelopathy versus ANNPE. Meningeal enhancement on postcontrast T1W FS MRI images and nonlongitudinal directional pattern of intramedullary hyperintensity on T2W FSE images were significantly associated with a diagnosis of ANNPE. Greater length of intramedullary hyperintensity was significantly associated with a diagnosis of ischemic myelopathy. CONCLUSIONS AND CLINICAL RELEVANCE Directional pattern and length of intramedullary hyperintensity on T2W FSE MRI images and enhancement patterns in postcontrast T1W FS sequences may provide important contributions to the criteria currently used in the presumptive diagnosis of ischemic myelopathy versus ANNPE.


Assuntos
Doenças do Cão/diagnóstico por imagem , Degeneração do Disco Intervertebral/veterinária , Núcleo Pulposo/patologia , Isquemia do Cordão Espinal/veterinária , Animais , Diagnóstico Diferencial , Doenças do Cão/patologia , Cães , Degeneração do Disco Intervertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/veterinária , Núcleo Pulposo/diagnóstico por imagem , Variações Dependentes do Observador , Estudos Retrospectivos , Isquemia do Cordão Espinal/diagnóstico por imagem
19.
J Small Anim Pract ; 57(4): 194-204, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27000649

RESUMO

OBJECTIVE: To systematically evaluate the evidence reporting the diagnosis and management of meniscal injury in dogs with cranial cruciate ligament failure. STUDY DESIGN: Systematic literature review. MATERIALS AND METHODS: Research questions relating to the accuracy of diagnostic techniques for meniscal injury and the effects of meniscal treatment were defined. An electronic database search of PubMed and CAB Abstracts was performed during March 2015. Data were extracted for study participants, design, intervention, outcome measures and results. Studies were evaluated using a validated instrument for assessing methodological quality and assigned a Quality Index score. A level of evidence was then assigned to each study. RESULTS: Eighty-nine studies were identified. The median Quality Index score was 14 out of a possible 26. Twenty-seven studies were prospective case series, 31 retrospective case series, 16 animal research and 15 cadaveric studies. There were no class I or class II studies, 27 class III and 62 class IV studies. CONCLUSIONS: Despite a large number of publications the quality of evidence was generally low. No one study or combination of studies provided high quality evidence to support one diagnostic or surgical intervention over another for meniscal injuries in dogs with cranial cruciate ligament failure.


Assuntos
Ligamento Cruzado Anterior/fisiopatologia , Doenças do Cão/epidemiologia , Menisco/lesões , Animais , Artroscopia/veterinária , Doenças do Cão/diagnóstico , Doenças do Cão/terapia , Cães , Imageamento por Ressonância Magnética/veterinária , Menisco/diagnóstico por imagem , Menisco/cirurgia , Prevalência
20.
ALTEX ; 33(1): 29-36, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26537428

RESUMO

The safety of veterinary vaccines is assessed in clinical trials in Europe. The assessment of the local tissue reaction to vaccination by magnetic resonance imaging (MRI) could reduce the number of animals needed because repeated examinations can be performed in the same animal over time. The present study compared the evaluation of local tissue reactions to vaccination using MRI in live pigs with histopathology of porcine tissue, the current gold standard in regulatory safety testing. Eight piglets each were administered one of two commercial vaccines into marked injection sites. All animals were sedated and scanned repeatedly by MRI using a contrast agent up to day 29 after vaccination. On day 29, the animals were euthanized and underwent a pathological examination. The MRI results were compared with the pathomorphological findings at the injection site by regression analysis. The MR images and the pathological examinations yielded matching results concerning the sizes of the affected tissue volumes or areas. The use of MRI for regulatory safety testing can reduce the number of animals needed to 8 per examination group. The volume of a local reaction and its progression over time can be evaluated and documented. If persistent lesions develop a final pathomorphological examination is needed to identify the kind and local distribution of the reaction.


Assuntos
Histologia , Imageamento por Ressonância Magnética/veterinária , Suínos/imunologia , Vacinas/efeitos adversos , Alternativas aos Testes com Animais , Animais , Feminino , Masculino , Modelos Animais , Patologia , Segurança , Vacinação/veterinária , Vacinas/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA