Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 49(3): 814-822, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38150141

RESUMO

BACKGROUND: To determine the utility of virtual-monoenergetic imaging (VMI) at low energy levels from contrast-enhanced dual-layer dual-energy (DLDE) computed tomography enterography (CTE) in the preoperative assessment of internal penetrating lesions of Crohn's disease (CD). MATERIALS AND METHODS: Thirty-eight patients with penetrating lesions of CD by surgery undergoing contrast-enhanced DLDE CTE were retrospectively included. Polyenergetic imaging (PEI) and VMIs at low energy levels [40-70 kiloelectron volts (keV)] with 10 keV intervals were reconstructed. The objective parameters of image quality [noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] and the subjective parameter of image quality [diagnostic performance of lesions (DPL), overall image quality(OIQ)] of PEI and all VMIs at the low energy level were compared to determine the VMI on the optimal energy level. The lesion detection capability between PEI and the optimal VMI was compared. RESULTS: VMI40 was determined to be the optimal VMI among all VMIs at the low energy level for owning the best image quality. No significant difference was found in the detecting capability in penetrating lesions between VMI40 and PEI (p = 1.0), whereas a significant difference was found in the detecting capability in the bowel origin of the penetrating lesions (p = 0.004), the involved organ or structure by the fistula (p = 0.016) and the orifice of the fistula connected to the involved organ or structure ( p = 0.031) between them. CONCLUSIONS: Compared to conventional PEI, VMI40 improves the detection capability in anatomical details of penetrating lesions of CD, helping colorectal surgeons rationalizing preoperative plans of internal penetrating lesions of CD.


Assuntos
Doença de Crohn , Fístula , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Radiother Oncol ; 187: 109840, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37536377

RESUMO

BACKGROUND: Objective and subjective assessment of image quality of brain metastases on dual-energy computed tomography (DECT) virtual monoenergetic imaging (VMI) and its impact on target volume delineation. MATERIALS AND METHODS: 26 patients with 37 brain metastases receiving Magnetic Resonance Imaging (MRI) and DECT for stereotactic radiotherapy planning were included in this retrospective analysis. Lesion contrast (LC), contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed for reconstructed VMI at 63 keV and artificial 120 kV Computed Tomography (CT). Image contrast and demarcation of metastases between 120 kV CT, VMI and MRI were subjectively assessed. Brain metastases were delineated by four radiation oncologists on VMI with a fixed or free brain window and contours were compared to solely MRI-based delineation using the Dice similarity coefficient. RESULTS: LC, CNR and SNR were significantly higher in VMI than in 120 kV CT (p < 0.0001). Image contrast and lesion demarcation were significantly better on VMI compared to 120 kV CT (p < 0.0001). Mean gross tumor volume (GTV)/planning target volume (PTV) Dice similarity coefficients were 0.87/0.9 for metastases without imaging uncertainties (no artifacts, calcification or impaired visibility with MRI) but worse for metastases with imaging uncertainties (0.71/0.74). Target volumes delineated on VMI were around 5-10% smaller compared to MRI. CONCLUSION: Image quality of VMI is objectively and subjectively superior to conventional CT. VMI provides significant advantages in stereotactic radiotherapy planning with improved visibility of brain metastases and geometrically distortion-free representation of brain metastases. Beside a plausibility check of MRI-based target volume delineation, VMI might improve reliability and accuracy in target volume definition particularly in cases with imaging uncertainties with MRI.


Assuntos
Neoplasias Encefálicas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
3.
Acta Radiol ; 64(8): 2357-2362, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37157189

RESUMO

BACKGROUND: Evaluation for gastrointestinal leak is a frequent imaging indication, and dual-energy computed tomography (DECT) with oral or rectally administered contrast can be used to improve efficiency and diagnostic confidence. PURPOSE: To assess the value of the DECT iodine overlay (IO) reconstruction as a stand-alone image set compared to routine CT in assessing oral or rectal contrast leak from the gastrointestinal system. MATERIAL AND METHODS: A blinded, retrospective audit study was performed by three readers who each interpreted 50 studies performed for assessment of oral or rectal contrast leak that were acquired using DECT. Each reader independently assessed both the routine CT images and the images of the reconstructed IO for contrast leak in random order with a six-week "wash-out period" between readings. Clinical follow-up provided the reference standard. Readers recorded the presence/absence of a leak, diagnostic confidence, image quality score, and interpretation time for each image set. RESULTS: Pooled data for overall accuracy in identification of a leak increased from 0.81 (95% confidence interval [CI]=0.74-0.87) for routine CT to 0.91 (95% CI=0.85-0.95) with IO, and the area under the curve (AUC) was significantly higher for IO than routine CT (P = 0.015). Readers required significantly less time to interpret IO than routine CT (median improvement of 12.5 s per image using pooled data; P < 0.001) while maintaining diagnostic confidence and perceived image quality. CONCLUSION: Use of DECT IO reconstructions for identification of oral or rectal contrast leak requires less time to interpret than routine CT with improved accuracy and maintained diagnostic confidence and perceived image quality.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Trato Gastrointestinal , Meios de Contraste
4.
AJR Am J Roentgenol ; 221(6): 720-730, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37073900

RESUMO

Among explored applications of dual-energy CT (DECT) in the abdomen and pelvis, the genitourinary (GU) tract represents an area where accumulated evidence has established the role of DECT to provide useful information that may change management. This review discusses established applications of DECT for GU tract assessment in the emergency department (ED) setting, including characterization of renal stones, evaluation of traumatic injuries and hemorrhage, and characterization of incidental renal and adrenal findings. Use of DECT for such applications can reduce the need for additional multiphase CT or MRI examinations and reduce follow-up imaging recommendations. Emerging applications are also highlighted, including use of low-energy virtual monoenergetic images (VMIs) to improve image quality and potentially reduce contrast media doses and use of high-energy VMIs to mitigate renal mass pseudoenhancement. Finally, implementation of DECT into busy ED radiology practices is presented, weighing the trade-off of additional image acquisition, processing time, and interpretation time against potential additional useful clinical information. Automatic generation of DECT-derived images with direct PACS transfer can facilitate radiologists' adoption of DECT in busy ED environments and minimize impact on interpretation times. Using the described approaches, radiologists can apply DECT technology to improve the quality and efficiency of care in the ED.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Radiologia , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Radiografia , Meios de Contraste , Serviço Hospitalar de Emergência
5.
J Med Imaging Radiat Oncol ; 67(4): 349-356, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36408756

RESUMO

INTRODUCTION: This study assessed replacing traditional protocol CT-arterial chest and venous abdomen and pelvis, with a single-pass, single-bolus, venous phase CT chest, abdomen and pelvis (CAP) protocol in general oncology outpatients at a single centre. METHODS: A traditional protocol is an arterial phase chest followed by venous phase abdomen and pelvis. A venous CAP (vCAP) protocol is a single acquisition 60 s after contrast injection, with optional arterial phase upper abdomen based on the primary tumour. Consecutive eligible patients were assessed, using each patient's prior study as a comparator. Attenuation for various structures, lesion conspicuity and dose were compared. Subset analysis of dual-energy (DE) CT scans in the vCAP protocol performed for lesion conspicuity on 50 keV virtual monoenergetic (VME) images. RESULTS: One hundred and eleven patients were assessed with both protocols. Forty-six patients had their vCAP scans using DECT. The vCAP protocol had no significant difference in the attenuation of abdominal structures, with reduced attenuation of mediastinal structures. There was a significant improvement in the visibility of pleural lesions (p < 0.001), a trend for improved mediastinal nodes assessment, and no significant difference for abdominal lesions. A significant increase in liver lesion conspicuity on 50 keV VME reconstructions was noted for both readers (p < 0.001). There were significant dose reductions with the vCAP protocol. CONCLUSION: A single-pass vCAP protocol offered an improved thoracic assessment with no loss of abdominal diagnostic confidence and significant dose reductions compared to traditional protocol. Improved liver lesion conspicuity on 50 keV VME images across a range of cancers is promising.


Assuntos
Neoplasias Hepáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Pacientes Ambulatoriais , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Pelve/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Meios de Contraste , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
6.
Eur Radiol ; 32(9): 6407-6417, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35380228

RESUMO

OBJECTIVES: To evaluate the diagnostic value of deep learning model (DLM) reconstructed dual-energy CT (DECT) low-keV virtual monoenergetic imaging (VMI) for assessing hypoenhancing hepatic metastases. METHODS: This retrospective study included 131 patients who underwent contrast-enhanced DECT (80-kVp and 150-kVp with a tin filter) in the portal venous phase for hepatic metastasis surveillance. Linearly blended images simulating 100-kVp images (100-kVp), standard 40-keV VMI images (40-keV VMI), and post-processed 40-keV VMI using a vendor-agnostic DLM (i.e., DLM 40-keV VMI) were reconstructed. Lesion conspicuity and diagnostic acceptability were assessed by three independent reviewers and compared using the Wilcoxon signed-rank test. The contrast-to-noise ratios (CNRs) were also measured placing ROIs in metastatic lesions and liver parenchyma. The detection performance of hepatic metastases was assessed by using a jackknife alternative free-response ROC method. The consensus by two independent radiologists was used as the reference standard. RESULTS: DLM 40-keV VMI, compared to 40-keV VMI and 100-kVp, showed a higher lesion-to-liver CNR (8.25 ± 3.23 vs. 6.05 ± 2.38 vs. 5.99 ± 2.00), better lesion conspicuity (4.3 (4.0-4.7) vs. 3.7 (3.7-4.0) vs. 3.7 (3.3-4.0)), and better diagnostic acceptability (4.3 (4.0-4.3) vs. 3.0 (2.7-3.3) vs. 4.0 (4.0-4.3)) (p < 0.001 for all). For lesion detection (246 hepatic metastases in 68 patients), the figure of merit was significantly higher with DLM 40-keV VMI than with 40-keV VMI (0.852 vs. 0.822, p = 0.012), whereas no significant difference existed between DLM 40-keV VMI and 100-kVp (0.852 vs. 0.842, p = 0.31). CONCLUSIONS: DLM 40-keV VMI provided better image quality and comparable diagnostic performance for detecting hypoenhancing hepatic metastases compared to linearly blended images. KEY POINTS: • DLM 40-keV VMI provides a superior image quality compared with 40-keV or 100-kVp for assessing hypoenhancing hepatic metastasis. • DLM 40-keV VMI has the highest CNR and lesion conspicuity score for hypoenhancing hepatic metastasis due to noise reduction and structural preservation. • DLM 40-keV VMI provides higher lesion detectability than standard 40-keV VMI (p = 0.012).


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
7.
Radiology ; 304(2): 353-362, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35438566

RESUMO

Background Grading of pelvic fracture instability is challenging in patients with pelvic binders. Dual-energy CT (DECT) and cinematic rendering can provide ancillary information regarding osteoligamentous integrity, but the utility of these tools remains unknown. Purpose To assess the added diagnostic value of DECT and cinematic rendering, with respect to single-energy CT (SECT), for discriminating any instability and translational instability in patients with pelvic binders. Materials and Methods In this retrospective analysis, consecutive adult patients (age ≥18 years) were stabilized with pelvic binders and scanned in dual-energy mode using a 128-section CT scanner at one level I trauma center between August 2016 and January 2019. Young-Burgess grading by orthopedists served as the reference standard. Two radiologists performed blinded consensus grading with the Young-Burgess system in three reading sessions (session 1, SECT; session 2, SECT plus DECT; session 3, SECT plus DECT and cinematic rendering). Lateral compression (LC) type 1 (LC-1) and anteroposterior compression (APC) type 1 (APC-1) injuries were considered stable; LC type 2 and APC type 2, rotationally unstable; and LC type 3, APC type 3, and vertical shear, translationally unstable. Diagnostic performance for any instability and translational instability was compared between reading sessions using the McNemar and DeLong tests. Radiologist agreement with the orthopedic reference standard was calculated with the weighted κ statistic. Results Fifty-four patients (mean age, 41 years ± 16 [SD]; 41 men) were analyzed. Diagnostic performance was greater with SECT plus DECT and cinematic rendering compared with SECT alone for any instability, with an area under the receiver operating characteristic curve (AUC) of 0.67 for SECT alone and 0.82 for SECT plus DECT and cinematic rendering (P = .04); for translational instability, the AUCs were 0.80 for SECT alone and 0.95 for SECT plus DECT and cinematic rendering (P = .01). For any instability, corresponding sensitivities were 61% (22 of 36 patients) for SECT alone and 86% (31 of 36 patients) for SECT plus DECT and cinematic rendering (P < .001). The corresponding specificities were 72% (13 of 18 patients) and 78% (14 of 18 patients), respectively (P > .99). Agreement (κ value) between radiologists and orthopedist reference standard improved from 0.44 to 0.76 for SECT versus the combination of SECT, DECT, and cinematic rendering. Conclusion Combined use of single-energy CT, dual-energy CT, and cinematic rendering improved instability assessment over that with single-energy CT alone. © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adolescente , Adulto , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Ossos Pélvicos/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
8.
Skeletal Radiol ; 51(5): 1027-1036, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34601617

RESUMO

OBJECTIVE: To evaluate the image quality of dual energy CT (DECT) of the shoulder after arthrography and of virtual non-contrast (VNC) 3D reformats of the glenoid and to compare glenoid measurements on VNC 3D reformats and on 2D CTs. MATERIALS AND METHODS: DECT arthrography (80 kV/140 kV) was performed in 42 shoulders of 41 patients with instability using diluted iodinated contrast media (80 mg/ml). VNC images and VNC 3D reformats of the glenoid were calculated using image postprocessing. Dose parameters, CT values of intraarticular iodine and muscle, image contrast (iodine/muscle), and image quality (5-point scale: 1 = worst, 5 = best) were evaluated. Two independent readers assessed glenoid morphology and performed glenoid measurements on 2D and 3D images. RESULTS: Calculation of VNC images and VNC 3D reformats was successful in 42/42 shoulders (100%). The effective dose was mean 1.95 mSv (± 0.9 mSv). CT values of iodine and muscle were mean 1014.6 HU (± 235.8 HU) and 64.5 HU(± 8.6 HU), respectively, and image contrast was mean 950.2 HU (± 235.5 HU). Quality of cross-sectional images, VNC images, and VNC 3D reformats was rated good (median 4 (4-5), 4 (3-4), 4 (3-5), respectively). Detection of an osseous defect was equal on 2D and 3D images (13/42, P > 0.99) with no difference for measurement of the glenoid diameter with mean 28.3 mm (± 2.8 mm) vs. 28.4 mm (± 2.9 mm) (P = 0.5), width of the glenoid defect with 3.2 mm (± 2.1 mm) vs. 3.1 mm (± 2.3 mm) (P = 0.84), surface area with 638.5 mm2 (± 127 mm2) vs. 640.8 mm2 (± 129.5 mm2) (P = 0.47), and surface area of the defect with 46.6 mm2 (± 44.3 mm2) vs. 47.2 mm2 (± 48.0 mm2) (P = 0.73), respectively. CONCLUSION: DECT shoulder arthrography is feasible and allows successful iodine removal with generation of VNC images and accurate VNC 3D reformats of the glenoid for assessment of bone loss.


Assuntos
Iodo , Instabilidade Articular , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Articulação do Ombro , Artrografia , Humanos , Instabilidade Articular/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
9.
Acta Radiol ; 63(4): 527-535, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33745295

RESUMO

BACKGROUND: In the assessment of diseases causing skeletal lesions such as multiple myeloma (MM), whole-body low-dose computed tomography (WBLDCT) is a sensitive diagnostic imaging modality, which has the potential to replace the conventional radiographic survey. PURPOSE: To optimize radiation protection and examine radiation exposure, and effective and organ doses of WBLDCT using different modern dual-source CT (DSCT) devices, and to establish local diagnostic reference levels (DRL). MATERIAL AND METHODS: In this retrospective study, 281 WBLDCT scans of 232 patients performed between January 2017 and April 2020 either on a second- (A) or third-generation (B) DSCT device could be included. Radiation exposure indices and organ and effective doses were calculated using a commercially available automated dose-tracking software based on Monte-Carlo simulation techniques. RESULTS: The radiation exposure indices and effective doses were distributed as follows (median, interquartile range): (A) second-generation DSCT: volume-weighted CT dose index (CTDIvol) 1.78 mGy (1.47-2.17 mGy); dose length product (DLP) 282.8 mGy·cm (224.6-319.4 mGy·cm), effective dose (ED) 1.87 mSv (1.61-2.17 mSv) and (B) third-generation DSCT: CTDIvol 0.56 mGy (0.47-0.67 mGy), DLP 92.0 mGy·cm (73.7-107.6 mGy·cm), ED 0.61 mSv (0.52-0.69 mSv). Radiation exposure indices and effective and organ doses were significantly lower with third-generation DSCT (P < 0.001). Local DRLs could be set for CTDIvol at 0.75 mGy and DLP at 120 mGy·cm. CONCLUSION: Third-generation DSCT requires significantly lower radiation dose for WBLDCT than second-generation DSCT and has an effective dose below reported doses for radiographic skeletal surveys. To ensure radiation protection, DRLs regarding WBLDCT are required, where our locally determined values may help as benchmarks.


Assuntos
Mieloma Múltiplo/diagnóstico por imagem , Exposição à Radiação/estatística & dados numéricos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Níveis de Referência de Diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos
10.
Radiology ; 301(1): 144-151, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34342502

RESUMO

Background Dual-energy CT enterography (DECTE) has been shown to be useful in characterizing Crohn disease activity compared with clinical markers of inflammation but, to the knowledge of the authors, comparison has not been made with histopathologic specimens. Purpose To compare mucosal iodine density obtained at DECTE from Crohn disease-affected bowel with histopathologic specimens from surgically resected ileocolectomy bowel segments or terminal ileum colonoscopic biopsies in the same patients. Materials and Methods This was a retrospective study. Bowel segments in adults with Crohn disease who underwent DECTE from January 2017 to April 2019 within 90 days of ileocolectomy or colonoscopy were retrospectively evaluated with prototype software allowing the semiautomatic determination of inner hyperdense bowel wall (mucosal) mean iodine density, normalized to the aorta. Mean normalized iodine density and clinical activity indexes (Crohn Disease Activity Index [CDAI] and Harvey-Bradshaw Index [HBI]) were compared with histologic active inflammation grades by using two-tailed t tests. Receiver operating characteristic curves were generated for mean normalized iodine density, CDAI, and HBI to determine sensitivity, specificity, and accuracy. A P value less than .05 was considered to indicate statistical significance. Results The following 16 patients were evaluated (mean age, 41 years ± 14 [standard deviation]): 10 patients (five men, five women; mean age, 41 years ± 15) with 19 surgical resection specimens and six patients with terminal ileum colonoscopic mucosal biopsies (four men, two women; mean age, 43 years ± 14). Mean normalized iodine density was 16.5% ± 5.7 for bowel segments with no active inflammation (n = 8) and 34.7% ± 9.7 for segments with any active inflammation (n = 17; P < .001). A 20% mean normalized iodine density threshold had sensitivity, specificity, and accuracy of 17 of 17 (100%; 95% CI: 80.5, 100), six of eight (75%; 95% CI: 35, 97), and 23 of 25 (92%; 95% CI: 74, 99), respectively, for active inflammation. Clinical indexes were similar for patients with and without active inflammation at histopathologic analysis (CDAI score, 261 vs 251, respectively [P = .77]; HBI score, 7.8 vs 6.4, respectively [P = .36]). Conclusion Iodine density from dual-energy CT enterography may be used as a radiologic marker of Crohn disease activity as correlated with histopathologic analysis. © RSNA, 2021 See also the editorial by Ohliger in this issue.


Assuntos
Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Inflamação/diagnóstico por imagem , Inflamação/patologia , Iodo/farmacocinética , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Biomarcadores , Meios de Contraste/farmacocinética , Doença de Crohn/complicações , Feminino , Humanos , Inflamação/etiologia , Intestinos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
11.
AJR Am J Roentgenol ; 215(6): 1528-1538, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32991217

RESUMO

OBJECTIVE. The purpose of this study was to analyze the contribution of dual-energy CT (DECT) to radiologist interpretation in the emergency department (ED) to determine whether recommendations for follow-up imaging decrease. MATERIALS AND METHODS. Reports of all DECT studies performed in an ED in 2016 were reviewed. A board-certified radiologist noted the number of times a report indicated that use of DECT techniques contributed to radiologist interpretation. For studies containing DECT findings in the report, the mixed datasets, representing conventional CT images, were read again separately. The difference between the numbers of follow-up studies recommended after conventional CT and DECT was converted into U.S. dollars by use of the Medicare fee schedule to estimate a projected cost benefit due to any reduction in follow-up imaging. RESULTS. The study included 3159 cases. DECT findings potentially altered management in 298 (9.4%) cases, increased diagnostic confidence in 455 (14.4%) cases, provided relevant information in 174 (5.6%) cases, helped characterize an incidental finding in 44 (1.4%) cases, and were mentioned to be noncontributory in three (0.09%) cases. DECT was not mentioned in the report in 2272 cases (71.9%). DECT findings avoided 162-191 recommended follow-up MRI examinations, 21-28 CT examinations, and 2-25 US examinations compared with conventional CT alone. The DECT findings also prompted one additional recommended interventional angiography procedure, one ventilation-perfusion scan, and one imaging-guided biopsy. The projected net cost reduction was $52,991.53-61,598.44. CONCLUSION. DECT added value to routine ED imaging by increasing diagnostic confidence, leading to a reduction in the number of recommended follow-up studies and a projected cost benefit.


Assuntos
Serviço Hospitalar de Emergência , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Meios de Contraste , Análise Custo-Benefício , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/economia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/economia , Procedimentos Desnecessários/economia
12.
J Comput Assist Tomogr ; 44(4): 578-585, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32649425

RESUMO

OBJECTIVE: The objective of this study was to assess the correlation between dual-energy computed tomography quantitative parameters and hemodynamics in patients with chronic thromboembolic pulmonary hypertension. METHODS: Dual-energy computed tomography of 52 chronic thromboembolic pulmonary hypertension patients were evaluated retrospectively. The mean lung perfused blood volume (lung PBV) and the mean pulmonary artery (PA) enhancement measured at pulmonary parenchymal phase were compared with the hemodynamics by Spearman rank correlation coefficient (rs) and receiver operating characteristic analysis. RESULTS: Lung PBV was correlated with mean pulmonary arterial pressure (rs = 0.47, P < 0.001). Pulmonary artery enhancement was correlated with cardiac index (rs = -0.49, P < 0.001) and pulmonary vascular resistance (rs = 0.48, P < 0.001). The areas under the curves were 0.86 for lung PBV to predict mean pulmonary arterial pressure of >50 mm Hg and 0.86 for PA enhancement to predict pulmonary vascular resistance of >1000 dyne·s/cm. CONCLUSIONS: Lung PBV and PA enhancement could be indicators of hemodynamics.


Assuntos
Hipertensão Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Volume Sanguíneo , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/fisiopatologia , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Adulto Jovem
13.
Medicine (Baltimore) ; 99(23): e20444, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32501991

RESUMO

This study aimed to compare the quality of virtual low-keV monoenergetic images vs conventional images reconstructed from dual-layer spectral detector computed tomography (SDCT) for the detection of peritoneal implants of ovarian cancer.Fifty ovarian cancer patients who underwent abdominopelvic SDCT scans were included in this retrospective study. Virtual monoenergetic images at 40 (VMI40) and 50 keV (VMI50), and two conventional images were reconstructed using filtered back projection (FBP) and iterative model reconstruction (IMR) protocols. The mean attenuation of the peritoneal implant, signal-to-noise ratio (SNR), contrast-to-noise ratio relative to ascites (CNRA) and adjacent reference tissues (e.g., bowel wall, hepatic, or splenic parenchyma [CNRB]) were calculated and compared using paired t tests. Qualitative image analysis regarding overall image quality, image noise, image blurring, lesion conspicuity, was performed by two radiologists. A subgroup analysis according to the peritoneal implant region was also conducted.VMI40 yielded significantly higher mean attenuation (183.35) of SNR and CNR values (SNR 11.69, CNRA 7.39, CNRB 2.68), compared to VMI50, IR, and FBP images (P < .001). The mean attenuation (129.65), SNR and CNR values (SNR 9.37, CNRA 5.72, CNRB 2.02) of VMI50 were also significantly higher than those of IR and FBP images (P < .001). In the subgroup analysis, all values were significantly higher on VMI40 regardless of the peritoneal implant region (P < .05). In both readers, overall image quality and image blurring showed highest score in VMI50, while image noise and lesion conspicuity showed best score in IMR and VMI40 respectively. Inter-reader agreements are moderate to almost perfect in every parameter.The low-keV VMIs improved both quantitative assessment and lesion conspicuity of peritoneal implants from ovarian cancer compared to conventional images.


Assuntos
Neoplasias Ovarianas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/epidemiologia , Peritônio/efeitos dos fármacos , Pesquisa Qualitativa , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , República da Coreia/epidemiologia , Estudos Retrospectivos
14.
Clin Imaging ; 63: 10-15, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32120307

RESUMO

INTRODUCTION: Dual-energy CT (DECT) can improve the accuracy of myocardial perfusion CT with projection-based monochromatic (DECT-MCE) and quantification of myocardial iodine in material decomposition (DECT-MD) reconstructions. However, evaluation of multiple reconstructions is laborious and the optimal reconstruction to detect myocardial perfusion defects is unknown. METHODS: Left ventricular (LV) phantoms with artificial perfusion defects were scanned using DECT and single energy cardiac computed tomography angiography (SECT). Reconstructions of DECT-MCE at 40, 70, 100 and 140 keV, DECT-MD pairs of water, iodine, iron and fat, and SECT were evaluated using a 17-segment myocardial model. The diagnostic performance of each reconstruction was calculated on a per-segment basis and compared across DECT reconstructions. RESULTS: Over 34 phantoms with artificial perfusion defects were found in 64/578 (11%) of segments, the sensitivity of DECT-MCE at 40, 70, 100, and 140 keV was 100% (95% confidence interval (CI): 93-100), 100% (95% CI: 93-100), 71% (95% CI: 56-83), and 25% (95% CI: 14-40), respectively, with a significant decline between 70 keV and 100 keV (p < 0.001). The specificity of DECT-MCE was 100% at all energies (95% CI: 99-100). As a group, the DECT-MD iodine background reconstructions had significantly lower sensitivity than the remaining modes (2.1% [95% CI, 0.05-11.1], vs. 100% [95% CI, 92.6-100], p < 0.001). Specificity of all material pair modes remained 100%. CONCLUSIONS: Using LV phantom models, the approach with the best sensitivity and specificity to assess myocardial perfusion defects with DECT are reconstructions of DECT-MCE at 40 or 70 KeV and DECT-MD without iodine background.


Assuntos
Imagem de Perfusão do Miocárdio , Algoritmos , Humanos , Iodo , Miocárdio , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
15.
BMC Med Imaging ; 19(1): 64, 2019 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-31399078

RESUMO

BACKGROUND: Our aim was to compare CT images from native, nephrographic and excretory phases using image quality criteria as well as the detection of positive pathological findings in CT Urography, to explore if the radiation burden to the younger group of patients or patients with negative outcomes can be reduced. METHODS: This is a retrospective study of 40 patients who underwent a CT Urography examination on a 192-slice dual source scanner. Image quality was assessed for four specific renal image criteria from the European guidelines, together with pathological assessment in three categories: renal, other abdominal, and incidental findings without clinical significance. Each phase was assessed individually by three radiologists with varying experience using a graded scale. Certainty scores were derived based on the graded assessments. Statistical analysis was performed using visual grading regression (VGR). The limit for significance was set at p = 0.05. RESULTS: For visual reproduction of the renal parenchyma and renal arteries, the image quality was judged better for the nephrogram phase (p < 0.001), whereas renal pelvis/calyces and proximal ureters were better reproduced in the excretory phase compared to the native phase (p < 0.001). Similarly, significantly higher certainty scores were obtained in the nephrogram phase for renal parenchyma and renal arteries, but in the excretory phase for renal pelvis/calyxes and proximal ureters. Assessment of pathology in the three categories showed no statistically significant differences between the three phases. Certainty scores for assessment of pathology, however, showed a significantly higher certainty for renal pathology when comparing the native phase to nephrogram and excretory phase and a significantly higher score for nephrographic phase but only for incidental findings. CONCLUSION: Visualisation of renal anatomy was as expected with each post-contrast phase showing favourable scores compared to the native phase. No statistically significant differences in the assessment of pathology were found between the three phases. The low-dose CT (LDCT) seems to be sufficient in differentiating between normal and pathological examinations. To reduce the radiation burden in certain patient groups, the LDCT could be considered a suitable alternative as a first line imaging method. However, radiologists should be aware of its limitations.


Assuntos
Rim/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Artéria Renal/diagnóstico por imagem , Urografia/instrumentação , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Rim/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Tecido Parenquimatoso/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/instrumentação
16.
PLoS One ; 14(7): e0219577, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31287838

RESUMO

This retrospective study was aimed to evaluate the reduced iodine load on image quality and diagnostic performance in multiphasic hepatic CT using a novel monoenergetic reconstruction algorithm (nMERA) in assessment of local tumor progression after radiofrequency ablation (RFA) of hepatocellular carcinoma (HCC). Ninety patients who underwent CT 1 month after RFA of HCC. Forty-five patients had multiphasic hepatic dual-energy CT with a half-reduced contrast medium (HRCM) of 277.5 mg I/kg. The nMERA (40-70-keV) images were reconstructed in each phase. Another 45 patients received a standard contrast medium (SCM) of 555 mg I/kg, and the images were reconstructed as a simulated 120-kVp images. Primary outcome was accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) in assessment of local tumor progression. Additional advanced assessments included the image noise, attenuation value, contrast-to-noise ratio (CNR), and subjective image quality between the groups. The accuracy, sensitivity and specificity of nMERA HRCM images were 95.7%, 100% and 93.9% for 40 keV, 95.7%, 85.7% and 100% for 50 keV, 83.0%, 42.8% and 100% for 60 keV, and 83.0%, 42.9% and 100% for 70 keV. The AUROC was 0.99, 0.99, 0.94, and 0.93 for 40-70 keV nMERA HRCM images, respectively. Compared with simulated 120-kVp SCM images, nMERA HRCM images demonstrated comparable noise at 70-keV (P < 0.05), and comparable CNR at 40- and 50-keV (P < 0.05). nMERA DECT enables the contrast medium to be reduced to up to 50% in multiphasic hepatic CT while preserving diagnostic accuracy.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Técnicas de Ablação , Idoso , Carcinoma Hepatocelular/terapia , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Iodo , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Curva ROC , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
17.
Eur Radiol ; 29(6): 2837-2847, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30377793

RESUMO

OBJECTIVES: To evaluate the image quality of virtual-monoenergetic-imaging (VMI) from dual-layer dual-energy CT (DLCT) for the assessment of hypovascular liver metastases and its effect on lesion detectability. METHODS: Eighty-one patients with hypovascular-liver-metastases undergoing portal-venous-phase abdominal DLCT were included. Polyenergetic-images (PEI) and VMI at 40-200 keV (VMI40-200, 10-keV interval) were reconstructed. Image noise, tumor-to-liver contrast, and contrast-to-noise ratio (CNR) of hepatic parenchyma and metastatic nodules (n = 288) were measured to determine the optimal monoenergetic levels. Two radiologists independently and subjectively assessed the image quality (image contrast, image noise, and diagnostic confidence) of PEI and optimal VMI on 5-point scales to determine the best energy. For 38 patients having up to 10 metastases each with diameters < 25 mm (153 lesions), we compared blindly assessed lesion detectability and conspicuity between PEI and VMI at the best energy. RESULTS: Image noise of VMI40-200 was consistently lower than that of PEI (p < 0.01). Tumor-to-liver contrast and CNR increased as the energy decreased with CNR at VMI40-70 being higher than that observed on PEI (p < 0.01). The highest subjective score for diagnostic confidence was assigned at VMI40 followed by VMI50-70, all of which were significantly better than that of PEI (p < 0.01, kappa = 0.75). Lesion detectability at VMI40 was significantly superior to PEI, especially for lesions with diameters of < 10 mm (p < 0.01, kappa ≥ 0.6). CONCLUSIONS: VMI40-70 provided a better subjective and objective image quality for the evaluation of hypovascular liver metastases, and the lesion detectability was improved with use of VMI40 compared with conventional PEI. KEY POINTS: • DLCT-VMI at 40-70 keV provides a superior subjective and objective image quality compared with conventional PEI for the assessment of hypovascular hepatic metastases during portal venous phase. • Tumor-to-liver contrast and CNR of hypovascular hepatic metastases was maximized at 40 keV without a relevant increase in the image noise. • VMI at 40 keV yields a superior lesion detectability, especially for small (< 1 cm) metastatic nodules compared with conventional PEI.


Assuntos
Neoplasias Hepáticas/diagnóstico , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
18.
Abdom Radiol (NY) ; 44(3): 1019-1026, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30415309

RESUMO

PURPOSE: The purpose of this study was to investigate the image quality (IQ) considerations of rapid kVp switching dual-energy CT (rsDECT) in the assessment of urolithiasis in patients with large body habitus and to evaluate whether it allows stone characterization. MATERIALS AND METHODS: In this IRB-approved, HIPAA compliant retrospective study, 93 consecutive patients (M/F = 72/21, mean age 56.9 years, range 23-83 years) with large body habitus (> 90 kg/198 lbs) who underwent dual-energy (DE) stone protocol CT on a rapid kVp switching DECT scanner between January 2013 and December 2016 were included. Scan acquisition protocol included an initial unenhanced single-energy CT (SECT) scan of KUB followed by targeted DECT in the region of stones. Two readers evaluated both CT data sets (axial 5 mm 120 kVp/140 kVp QC/70 keV monoenergetic, material density water/iodine images and coronal/sagittal 3 mm images) for the assessment of image quality (Scores: 1-4) and characterization of stone composition (reference standard: crystallography). RESULTS: One hundred and five CT examinations were performed in 93 patients (mean body weight 105.12 ± 13.53 kg, range 91-154 kg), and a total of 321 urinary tract calculi (mean size-4.8 ± 3.2 mm, range 1.2-22 mm) were detected. Both SECT and targeted monoenergetic images were of acceptable image quality (mean IQ: 3.77 and 3.83, kappa 0.79 and 0.87 respectively). Material density water and iodine images had lower IQ scores (mean IQ: 2.97 and 3.09 respectively) with image quality deterioration due to severe photon starvation/streak artifacts in 20% (21/105) and 17% (18/105) scans, respectively. Characterization of stone composition into uric acid/non-uric acid stones was achieved in 93.14% (299/321) of calculi (mean size: 4.99 ± 3.3 mm, range 1.2-22 mm), while 7% (22/321) stones could not be characterized (mean size 3.03 ± 1.16 mm, range 1.6-6.4 mm) (p < 0.001). Most common reason for non-characterization was image quality deterioration of the material density iodine images due to severe photon starvation artifacts. On multivariate regression, stone size and patient weight were predictors of stone composition determination on DECT (p < 0.05). The transverse diameter had a weak negative correlation with stone composition determination, but it was not statistically significant. Stone characterization into uric acid vs. non-uric acid stones was accurate in 95% (n = 38/40) of stones in comparison with crystallography. CONCLUSION: In patients with large body habitus, rsDECT allowed characterization of most calculi (93%) despite image quality deterioration due to photon starvation/streak artifacts in up to 20% of material density images. Stone size and patient weight were predictors of stone composition determination on DECT, and small calculi in very large patients may not be characterized.


Assuntos
Tamanho Corporal , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Urolitíase/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
19.
J Comput Assist Tomogr ; 42(6): 925-931, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30371610

RESUMO

OBJECTIVE: The aim of the study was to establish the reference window settings for display of virtual monoenergetic images (VMIs) from spectral detector computed tomography when assessing hypodense liver lesions. METHODS: In patients with cysts (n = 24) or metastases (n = 26), objective (HU, signal-to-noise ratio [SNR]) and subjective (overall image quality, lesion conspicuity and noise) were assessed. Furthermore, 2 readers determined optimal window center/width (C/W) for conventional images (CIs) and VMIs of 40 to 120 keV. Center/width were modeled against HUliv with and without respect to the keV level (models A and B). RESULTS: Attenuation and SNR were significantly higher in low-keV VMIs and improved overall image quality and lesion conspicuity (P ≤ 0.05). Model B provided valid estimations of C/W, whereas model A was slightly less accurate. CONCLUSIONS: The increase in attenuation and SNR on low-keV VMIs requires adjustment of C/W, and they can be estimated in dependency of HUliv using linear models. Reference values for standard display of VMIs of 40 to 120 keV are reported.


Assuntos
Hepatopatias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Biópsia , Meios de Contraste , Feminino , Humanos , Hepatopatias/patologia , Masculino , Estudos Prospectivos , Valores de Referência , Razão Sinal-Ruído
20.
Eur J Radiol ; 106: 184-191, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30150043

RESUMO

PURPOSE: To assess the value of the noise-optimized virtual monoenergetic imaging (VMI+) technique on quantitative and qualitative image parameters in patients with hypoattenuating liver metastases from colorectal cancer (CRC) at abdominal dual-energy CT (DECT). MATERIALS AND METHODS: Fifty-three consecutive patients (mean age, 70.3 ± 11.4 years; range, 44-86 years) with histologically proven, hypoattenuating liver metastases from CRC were retrospectively included in this IRB-approved study. DECT datasets were reconstructed as standard linearly-blended M_0.6 image series, traditional virtual monoenergetic images (VMI), and noise-optimized VMI+ series. VMI and VMI+ reconstructions were obtained at energy levels ranging from 40 to 100-keV with 10-keV increments. Signal attenuation of liver parenchyma and liver metastases was measured to calculate signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Each image series was subjectively rated by three blinded radiologists with regard to image quality, lesion delineation, and image noise using a five-point Likert scale. RESULTS: Quantitative image quality parameters peaked at 40-keV VMI+ (SNR, 8.1 ± 3.4; CNR, 6.5 ± 2.6) with statistically significant differences in comparison with standard reconstructions and all traditional VMI series (P ≤ 0.001). Qualitative image analysis revealed best rating scores for 60-keV VMI+ series (median, 5) with significant differences compared to linearly-blended M_0.6 and all traditional VMI series (P ≤ 0.001). Lesion delineation showed significantly superior ratings for 40-keV VMI+ series compared to all other reconstructions (median, 5) (P ≤ 0.001). CONCLUSION: Low-keV VMI+ reconstructions demonstrate significantly increased quantitative and qualitative image quality parameters in patients with hypoattenuating liver metastases from CRC in comparison with standard reconstructions and traditional VMI series at abdominal DECT. Best lesion delineation can be achieved at 40-keV VMI+.


Assuntos
Neoplasias Colorretais/patologia , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA