Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 250
Filtrar
Mais filtros

Intervalo de ano de publicação
2.
Eur J Nucl Med Mol Imaging ; 49(7): 2219-2231, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35150293

RESUMO

PURPOSE: The purpose of the present study was to evaluate the feasibility of gated blood pool single-photon emission computed tomography (GBPS) with low-dose dobutamine (LDD) stress test, performed on a single-photon emission computed tomography (SPECT) camera equipped with cadmium-zinc-telluride (CZT) solid-state detectors, in assessing of left ventricle (LV) contractile reserve in patients with ischemic cardiomyopathy (ICM). METHODS: A total of 52 patients (age 59 ± 7.2 years, 47 men and 5 women) with ICM and a control group of 10 patients without obstructive coronary artery lesion underwent GBPS and transthoracic echocardiography (TTE) at rest and during LDD stress test (5, 10, 15 µg/kg/min). The duration of each GBPS step was 5 min. Stress-induced changes in LV ejection fraction (ΔLVEF), peak ejection rate, LV volumes, and mechanical dyssynchrony (phase histogram standard deviation, phase histogram bandwidth and entropy) obtained with GBPS were estimated. RESULTS: All GBPS indices except end-diastolic volume showed significant dynamics during stress test in both groups. The majority of parameters in ICM patients showed significant changes at a dobutamine dose of 10 µg/kg/min as compared to the rest study. Seventeen percent of ICM patients, but none from the control group, showed a decrease in LVEF during stress, accompanied by a significant increase in entropy. The intra- and inter-observer reproducibility was excellent for both rest and stress studies. There was a moderate correlation (r = 0.5, p = 0.01) between GBPS and TTE, with a mean difference value of - 1.7 (95% confidence interval - 9.8; 6.4; p = 0.06) in ΔLVEF. CONCLUSION: Low-dose dobutamine stress GBPS performed with high-efficiency CZT-SPECT cameras can be performed for evaluating stress-induced changes in LV contractility and dyssynchrony with lower acquisition time. A dobutamine dose of 10 µg/kg/min can potentially suffice to detect stress-induced changes in patients with ICM during GBPS. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT04508608 (August 7, 2020).


Assuntos
Cardiomiopatias , Isquemia Miocárdica , Disfunção Ventricular Esquerda , Idoso , Dobutamina , Estudos de Viabilidade , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/diagnóstico por imagem , Reprodutibilidade dos Testes , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem
4.
Am J Cardiol ; 156: 85-92, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34344513

RESUMO

Two widely used methods for left ventricular (LV) ejection fraction (EF) determination, echocardiography (echo) and gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), often have wide limits of agreement. Factors influencing discrepancies between core laboratory echo and MPI LVEF determinations were examined in a large series of heart failure (HF) subjects and normal controls. 879 HF and 101 control subjects had core lab analyses of echo and MPI (mean time between procedures 7-8 days). LVEF differences were analyzed using one-way analysis of variance and Bland-Altman plots. Relationships between LVEF differences and patient characteristics and outcome endpoints (mortality and arrhythmias) were explored with logistic regression, Cox proportional hazards models, and Kaplan-Meier survival analyses. There was a systematic difference between the 2 modalities; echo LVEF was higher with more severe LV dysfunction, MPI LVEF higher when systolic function was normal. LVEF results were within ±5% in only 37% of HF and 23% of control subjects. Considering discordance around the LVEF threshold 35%, there was disagreement between the 2 methods in 305 HF subjects (35%). Male gender (odds ratio (OR) = 0.200), atrial fibrillation (OR = 2.314), higher body mass index (OR = 1.051) and lower LV end-diastolic volume (OR = 0.985) were the strongest predictors of methodologic discordance. Cardiac event rates were highest if both LVEF values were ≤35% and lowest when both LVEF values were >35%. In conclusion, substantial disagreements between LVEF results by echo and MPI are common. HF patients with LVEF ≤35% by both techniques have the highest 2-year event risk.


Assuntos
Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Feminino , Seguimentos , Imagem do Acúmulo Cardíaco de Comporta/métodos , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos
5.
J Nucl Cardiol ; 28(2): 594-603, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-31044403

RESUMO

PURPOSE: We appraised the feasibility of left ventricle (LV) function assessment using gated first-pass 18F-FDG PET, and assessed the concordance of the produced measurements with equilibrium radionuclide angiography (ERNA). MATERIALS AND METHODS: Twenty-four oncologic patients benefited from 99mTc-labeled red-blood-cell ERNA, in planar mode (all patients) and using SPECT (22 patients). All patients underwent gated first-pass 18F-FDG cardiac PET. Gated dynamic PET images were reconstructed over 1 minute during tracer first-pass inside the LV and post-processed using in-house software (TomPool). After re-orientation into cardiac canonical axes and adjustment of the valves plane using a phase image, pseudo-planar PET images obtained by re-projection were automatically segmented using thresholded region growing and gradient-based delineation to produce an LV ejection fraction (EF) estimate. PET images were also post-processed in fully-tomographic mode to produce LV end diastole volume (EDV), end systole volume (ESV), and EF estimates. Concordance was assessed using Lin's concordance (ccc) and Bland-Altman analysis. Reproducibility was assessed using the coefficient of variation (CoV) and intra-class correlation (ICC). RESULTS: Pseudo-planar PET EF estimates were concordant with planar ERNA (ccc = 0.81, P < .001) with a bias of 0% (95% CI [- 2%; 3%], limits of agreement [- 11%; 12%]). Reproducibility was excellent and similar for both methods (CoV = 2 ± 1% and 3 ± 2%, P = NS; ICC = 0.97 and 0.92, for PET and ERNA, respectively). Measurements obtained in fully-tomographic mode were concordant with SPECT ERNA: ccc = 0.83 and bias = - 3 mL for LV EDV, ccc = 0.92 and bias = 0 mL for LV ESV, ccc = 0.89 and bias = - 1% for LV EF (all P values < .001 for ccc, all biases not significant). CONCLUSIONS: Gated first-pass 18F-FDG PET might stand as a relevant alternative to ERNA for LV function assessment, enabling a joint evaluation of both therapeutic response and cardiac toxicity in oncologic patients receiving cardiotoxic chemotherapy.


Assuntos
Angiografia/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda , Adulto , Idoso , Feminino , Fluordesoxiglucose F18/química , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão , Estudos Prospectivos , Radioisótopos/química , Radiometria , Reprodutibilidade dos Testes , Software , Sístole , Tecnécio/química , Adulto Jovem
6.
J Nucl Cardiol ; 28(3): 864-872, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-31201690

RESUMO

BACKGROUND: Quantitative assessment of valve regurgitation using volumetric method by comparing right and left ventricular stroke volumes is still under investigations. AIMS: To investigate the accuracy of tomographic equilibrium radionuclide ventriculography (t-ERV) for the quantification of tricuspid regurgitation (TR). METHODS AND RESULTS: Sixty-one patients (44 men; mean age 59 ± 12 years) who underwent both t-ERV and transthoracic echocardiography (TTE) studies within 2 weeks for right ventricular systolic function assessment were eligible for inclusion. A sub-group of 22 patients underwent both t-ERV and CMR. Patients with mitral/aortic regurgitation by TTE were excluded of the study. TR regurgitant volume (RVol) was calculated using the proximal isovelocity surface area (PISA) method from TTE and the volumetric method (right ventricular stroke volume minus left ventricular stroke volume) from t-ERV. There was a significant correlation between RVol as assess by ERV and by TTE (R = 0.95, P < 0.0001). Intraclass correlation coefficient between TTE and ERV for TR quantification was 0.95 (P < 0.0001). Among patients who underwent CMR, the correlation between RVol obtained by TTE and by t-ERV and CMR were R = 0.81 and R = 0.75, respectively (all P < 0.0001). CONCLUSION: TR assessment using the t-ERV correlates well with PISA from TTE in patients referred for right ventricular systolic function assessment.


Assuntos
Volume Sistólico , Insuficiência da Valva Tricúspide/fisiopatologia , Valva Tricúspide/fisiopatologia , Idoso , Insuficiência da Valva Aórtica , Estudos Transversais , Ecocardiografia , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Lineares , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Estudos Retrospectivos , Sístole
7.
Curr Med Imaging ; 17(5): 623-633, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33213328

RESUMO

BACKGROUND: In this paper, we propose a new efficient method of radionuclide ventriculography image segmentation to estimate the left ventricular ejection fraction. This parameter is an important prognostic factor for diagnosing abnormal cardiac function. METHODS: The proposed method combines the Chan-Vese and the mathematical morphology algorithms. It was applied to diastolic and systolic images obtained from the Nuclear Medicine Department of Salah AZAIEZ Institute. In order to validate our proposed method, we compare the obtained results to those of two methods present in the literature. The first one is based on mathematical morphology, while the second one uses the basic Chan-Vese algorithm. To evaluate the quality of segmentation, we compute accuracy, positive predictive value and area under the ROC curve. We also compare the left ventricle ejection fraction estimated by our method to that of the reference given by the software of the gamma-camera and validated by the expert, using Pearson's correlation coefficient, ANOVA test and linear regression. RESULTS: Static results show that the proposed method is very efficient for the detection of the left ventricle. The accuracy was 98.60%, higher than that of the other two methods (95.52% and 98.50%). CONCLUSION: Likewise, the positive predictive value was the highest (86.40% vs. 83.63% 71.82%). The area under the ROC curve was also the most important (0.998% vs. 0.926% 0.919%). On the other hand, Pearson's correlation coefficient was the highest (99% vs. 98% 37%). The correlation was significantly positive (p<0.001).


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Função Ventricular Esquerda , Ventrículos do Coração/diagnóstico por imagem , Ventriculografia com Radionuclídeos , Volume Sistólico
8.
J Nucl Cardiol ; 28(4): 1304-1314, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31385225

RESUMO

BACKGROUND: This study aimed to assess intra- and inter-observer agreement in assessing the systolic and diastolic function with equilibrium radionuclide angiography (ERNA). MATERIALS AND METHODS: Thirty-two adults underwent baseline and repeat ERNA. An experienced and a trainee operator analyzed the data by assigning regions of interest manually, fully automatically, and semi-automatically. The Bland-Altman statistic (mean ± 1.96 standard deviations of the differences) was used to assess the repeatability (two different assessments of a single acquisition) and reproducibility (assessments of two different acquisitions). RESULTS: Using the semi-automated technique the intraobserver repeatability and reproducibility of left ventricular ejection fraction for the experienced physician were - 0.1 ± 3.7 and 0.0 ± 3.8 and for the trainee 2.2 ± 10.6 and 1.9 ± 8.4, respectively. The inter-observer repeatability and reproducibility were - 1.8 ± 6.4 and 0.4 ± 9.0, respectively. Among the parameters of diastolic function, the intraobserver repeatability and reproducibility of the peak filling rate for the experienced physician were - 0.0 ± 1.1 and - 0.1 ± 1.1 and for the trainee 0.2 ± 3.5 and 0.4 ± 3.7, respectively. The inter-observer repeatability and reproducibility were 0.3 ± 1.5 and 0.5 ± 4.0, respectively. Similar was the pattern for the other diastolic indices. In all cases the limits of agreement varied according to the quantification approach. CONCLUSION: A good repeatability but a moderate reproducibility was found in the assessment of the LVEF. Less good were the findings in the assessment of diastolic function.


Assuntos
Angiografia Coronária , Diástole/fisiologia , Imagem do Acúmulo Cardíaco de Comporta , Cardiopatias/fisiopatologia , Angiografia Cintilográfica , Sístole/fisiologia , Adulto , Idoso , Feminino , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia
9.
J Nucl Cardiol ; 27(6): 2017-2026, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30426398

RESUMO

PURPOSE: To compare, vs CMR, four softwares: quantitative gated SPECT (QGS), myometrix (MX), corridor 4DM (4DM), and Emory toolbox (ECTb) to evaluate left ventricular ejection fraction (LVEF), end-systolic (ESV), and end-diastolic volumes (EDVs) by gated MPI CZT-SPECT. METHODS: 48 patients underwent MPI CZT-SPECT and CMR 6 weeks after STEMI, LV parameters were measured with four softwares at MPI CZT-SPECT vs CMR. We evaluated (i) concordance and correlation between MPI CZT-SPECT and CMR, (ii) concordance MPI CZT-SPECT/CMR for the categorical evaluation of the left ventricular dysfunction, and (iii) impacts of perfusion defects > 3 segments on concordance. RESULTS: LVEF: LCC QGS/CMR = 0.81 [+ 2.2% (± 18%)], LCC MX/CMR = 0.83 [+ 1% (± 17.5%)], LCC 4DM/CMR = 0.73 [+ 3.9% (± 21%)], LCC ECTb/CMR = 0.69 [+ 6.6% (± 21.1%)]. ESV: LCC QGS/CMR = 0.90 [- 8 mL (± 40 mL)], LCC MX/CMR = 0.90 [- 9 mL (± 36 mL)], LCC 4DM/CMR = 0.89 [+ 4 mL (± 45 mL)], LCC ECTb/CMR = 0.87 [- 3 mL (± 45 mL)]. EDV: LCC QGS/CMR = 0.70 [- 16 mL (± 67 mL)], LCC MX/CMR = 0.68 [- 21 mL (± 63 mL], LCC 4DM/CMR = 0.72 [+ 9 mL (± 73 mL)], LCC ECTb/CMR = 0.69 [+ 10 mL (± 70 mL)]. CONCLUSION: QGS and MX were the two best-performing softwares to evaluate LVEF after recent STEMI.


Assuntos
Cádmio , Imagem do Acúmulo Cardíaco de Comporta/métodos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda , Zinco , Adulto , Idoso , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Software , Volume Sistólico , Tecnécio Tc 99m Sestamibi , Disfunção Ventricular Esquerda
10.
Breast Cancer Res Treat ; 176(2): 261-270, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31020471

RESUMO

BACKGROUND: There is a lack of consensus to guide which breast cancer patients require left ventricular function assessment (LVEF) prior to anthracycline therapy; the cost-effectiveness of screening this patient population has not been previously evaluated. METHODS: We performed a retrospective analysis of the Yale Nuclear Cardiology Database, including 702 patients with baseline equilibrium radionuclide angiography (ERNA) scan prior to anthracycline and/or trastuzumab therapy. We sought to examine associations between abnormal baseline LVEF and potential cardiac risk factors. Additionally, we designed a Markov model to determine the incremental cost-effectiveness ratio (ICER) of ERNA screening for women aged 55 with stage I-III breast cancer from a payer perspective over a lifetime horizon. RESULTS: An abnormal LVEF was observed in 2% (n = 14) of patients. There were no significant associations on multivariate analysis performed on self-reported risk factors. Our analysis showed LVEF screening is cost-effective with ICER of $45,473 per QALY gained. For a willingness-to-pay threshold of $100,000/ QALY, LVEF screening had an 81.9% probability of being cost-effective. Under the same threshold, screening was cost-effective for non-anthracycline cardiotoxicity risk of RR ≤ 0.58, as compared to anthracycline regimens. CONCLUSIONS: Age, preexisting cardiac risk factors and coronary artery disease did not predict a baseline abnormal LVEF. While the prevalence of an abnormal baseline LVEF is low in patients with breast cancer, our results suggest that cardiac screening prior to anthracycline is cost-effective.


Assuntos
Antraciclinas/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Cardiotoxicidade/diagnóstico por imagem , Imagem do Acúmulo Cardíaco de Comporta/economia , Trastuzumab/uso terapêutico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Antraciclinas/efeitos adversos , Neoplasias da Mama/patologia , Cardiotoxicidade/economia , Análise Custo-Benefício , Feminino , Humanos , Cadeias de Markov , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Retrospectivos , Autorrelato , Trastuzumab/efeitos adversos , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/economia , Função Ventricular Esquerda
11.
J Nucl Cardiol ; 26(6): 1857-1864, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-29520572

RESUMO

BACKGROUND: IQ-SPECT has been shown to significantly reduce acquisition time and administered dose while preserving image quality in myocardial perfusion imaging. Whether IQ-SPECT provides accurate left ventricular ejection fractions (LVEF) with gated blood pool SPECT (GBPS) remains unknown. METHODS: Sixty patients underwent IQ-SPECT GBPS and planar imaging. Among those patients, 11 underwent both cMRI and GBPS. GBPS LVEF, LVEDV, and LVESV were calculated using 2 validated software; QBS (Cedars-Sinai Medical Center, Los Angeles, USA) and MHI (Montreal Heart Institute, Montreal, Canada). LVEF, LVEDV, and LVESV obtained with the different modalities were compared. RESULTS: Average planar LVEF was 48 ± 11% (mean ± SD), average LVEDV was 177 ± 59 mL (range 63 to 342 mL), and average LVESV was 96 ± 46 mL (range 16 to 234 mL). GBPS LVEF and their correlation coefficient with planar LVEF were 40 ± 12% (r = 0.70) and 44 ± 12% (r = 0.83) with QBS and MHI, respectively. Correlation coefficient between cMRI and planar LVEF was 0.65 and were 0.69 and 0.52 between cMRI and GBPS using QBS and MHI, respectively. CONCLUSIONS: LVEF calculated with GBPS using IQ-SPECT correlates with planar measurements. Correlation is best using the MHI method and variation is independent of LVEDV.


Assuntos
Angiografia/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Miocardite/diagnóstico por imagem , Software , Volume Sistólico , Disfunção Ventricular Esquerda , Função Ventricular Esquerda
12.
Hell J Nucl Med ; 21(3): 213-220, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30534636

RESUMO

18 The non-invasive assessment of left ventricular function with simple indices, such as left ventricular volumes and ejection fraction (LVEF), offers significant diagnostic and prognostic implications in the entire spectrum of cardiac diseases. Equilibrium radionuclide ventriculography (RNV) is a well validated technique for this purpose. Based on the principle that the amount of radioactivity emitted by technetium-99m (99mTc)-pertechnate labeled erythrocytes in the cardiac chambers is proportional to the amount of bloodcontained, reproducible and accurate LVEF measurements can be obtained, with practically no geometric assumptions regarding heart shape. However, the development of other imaging techniques, mostly echocardiography and secondarily cardiac magnetic resonance has led to a decline in the use of RNV. This is due to easiness, cost and availability issues and also because competitive modalities can offer reliable anatomic and functional information and hence they can address a variety of clinical scenarios in one session. Nevertheless, RNV still remains a reliable method in clinical conditions, in which the detection of small changes in LVEF may be important in clinical decision-making, such as in patients undergoing cardiotoxic chemotherapy, when the images of different methods are of suboptimal quality or unobtainable, or there is discordance between clinical judgment and imaging results. In this respect the more recently introduced gated single photon emission tomography (SPET) myocardial perfusion imaging has not demonstrated equivalent reliability, in terms of independence from a variety of factors and accuracy of measurements on a per-patient basis. The purpose of this review is to present the features of RNV, and to define its role in the evaluation of cardiac function in the current era of medical imaging.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Coração/diagnóstico por imagem , Coração/fisiologia , Humanos , Processamento de Imagem Assistida por Computador
13.
J Nucl Cardiol ; 25(2): 625-634, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-27905008

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) require serial assessment of right and left ventricular (RV & LV) volumes and function. Because the RV is not assisted, its function is a critical determinant of the hemodynamic and contributes significantly to postoperative morbidity and mortality. We evaluated the feasibility and the accuracy of tomographic-equilibrium radionuclide ventriculography (t-ERV) for the assessment of patients with LVADs. METHODS: Twenty-four patients with LVAD underwent t-ERV. Because of the limited acoustic window, transthoracic echocardiography (TTE) was only feasible in 19 patients. Functional evaluation including six-minute walk test (6MWT) and peak oxygen consumption (POC) was performed in 18 patients. Nine patients underwent a cardiac multidetector computed tomography (MDCT). Eight patients underwent a second evaluation by ERV 4.3 ± 1.4 months later. RESULTS: Reliability between t-ERV and MDCT for LV end-diastolic volume, LV end-systolic volume, LV ejection fraction, RV end-diastolic volume, RV end-systolic volume, and RV ejection fraction (RVEF) was 0.900 (P = .001), 0.911 (P = .001), 0.765 (P = .021), 0.728 (P = .042), 0.875 (P = .004), and 0.781 (P = .023), respectively. There was no correlation between t-ERV and RV systolic parameters assessed by TTE. RVEF was correlated with POC (R = 0.521; P = .027). A cut-off value of 40% for RVEF measured by t-ERV could discriminate patients with poor functional status (P = .048 for NYHA stage; P = .016 for 6MWT and P = .007 for POC). CONCLUSION: t-ERV is a simple, reproducible, and an accurate technique for the assessment of RV function in patients with LVADs and warrants consideration in the evaluation and monitoring of symptomatic patients.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Coração Auxiliar , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/cirurgia , Idoso , Ecocardiografia , Teste de Esforço , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Variações Dependentes do Observador , Consumo de Oxigênio , Reprodutibilidade dos Testes , Volume Sistólico , Sístole , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Direita/diagnóstico por imagem
15.
Hell J Nucl Med ; 20(3): 222-226, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29177257

RESUMO

OBJECTIVE: The aim of this study is to investigate whether gated single photo emission tomography (gSPET) can be used to detect subclinical left ventricular systolic dysfunction (LVSD) in obese diabetic type II patients. SUBJECTS AND METHODS: We retrospectively reviewed gSPET images of 190 patients with diabetes mellitus type II (DM II) (137 females and 53 males) with normal myocardial perfusion and normal ejection fraction (EF). Standardized twenty segment polar maps of thickening and motion were generated. Correlation between body mass index (BMI) and thickening for each segment was performed. RESULTS: Statistically significant results were reported in female patients including: negative correlation between BMI and EF (-0.19, P=0.03). End diastolic volume (EDV) also significantly increased with increasing BMI (0.25, P<0.01). There was also statistically significant negative correlation between septal thickening and BMI segment 15 (-0.19, P=0.02), segment 16 (-0.22, P=0.01), segment 18 (-0.20, P=0.01), segment 19 (-0.25, P=0.003), segment 20 (-0.2, P=0.02)]. No statistical significant correlation was found between thickening and BMI in male patients. CONCLUSION: This is the first time where thickening as measured by gSPET has been used to demonstrate subclinical LVSD in DM II obese patients. The relationship between gender and obesity on cardiovascular function and structure needs further investigations.


Assuntos
Diabetes Mellitus Tipo 2/diagnóstico por imagem , Imagem do Acúmulo Cardíaco de Comporta/métodos , Ventrículos do Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Obesidade/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/patologia , Diagnóstico Diferencial , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/etiologia , Obesidade/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Hell J Nucl Med ; 20(3): 247-250, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29177264

RESUMO

We studied a 50 years old male patient who underwent cardiac resynchronization therapy on and off (CRT-on and CRT-off) for assessment of left ventricular (LV) function and mechanical systole synchrony using gated myocardial perfusion imaging (gMPI) and real-time three-dimensional echocardiography (RT3DE). The patient was reexamined after seven months. The comparison of these two modalities showed consistent results on assessing both the CRT-on and CRT-off conditions. This result may indicate that an immediate synchronization parameter change during CRT-on may be valuable for predicting response to CRT surgery.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia Tridimensional/métodos , Imagem do Acúmulo Cardíaco de Comporta/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/prevenção & controle , Adulto , Sistemas Computacionais , Seguimentos , Humanos , Masculino , Volume Sistólico , Resultado do Tratamento
17.
Nucl Med Commun ; 38(8): 715-719, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28658052

RESUMO

OBJECTIVES: Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. PATIENTS AND METHODS: In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. RESULTS: Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. CONCLUSION: Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Fluordesoxiglucose F18 , Imagem do Acúmulo Cardíaco de Comporta , Neoplasias Pulmonares/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Mediastino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Pulmonares/patologia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
18.
Eur Heart J Cardiovasc Imaging ; 18(1): 95-102, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26850628

RESUMO

AIMS: To determine the influence of cardiac motion on measurements of left ventricular (LV) mass obtained with 64-slice computed tomography (CT) and to elucidate the prognostic value of LV mass on major adverse cardiac events (MACE) and all-cause mortality. Increased LV mass has been linked with MACE. Although Cardiac CT allows measurement of LV anatomy, it is susceptible to motion artefacts often requiring image acquisition during diastasis. There is a need to understand variability in LV mass measurements across phases of the cardiac cycle, and whether mid-diastolic measurements have prognostic value. METHODS AND RESULTS: The study comprised two equally sized cohorts of patients that had undergone retrospectively gated cardiac CT: patients who had MACE and/or all-cause death at follow-up and a matched (age, sex, and risk factors) event-free cohort. LV mass was measured at mid-diastole, end-diastole, and end-systole. Correlation and agreement between phases were determined. The incremental value of mid-diastolic hypertrophy (LVH) over the National Cholesterol Education Programme (NCEP) risk was performed for LV mass indices normalized to body surface area (LVMIBSA) or weight (LVMIWeight). Of 166 patients, 31.3% experienced MACE and 28.9% died of any cause (follow-up 22.9 ± 13.4 months). LV mass at all cardiac phases were strongly correlated (r > 0.94). Mean mid-diastolic LVMIBSA was higher in the cohort with events (93.7 vs. 80.7 g/m2, P= 0.008) as was LVMIWeight (2.26 vs. 1.88 g/kg, P = 0.001). LVMIBSA and LVMIWeight had prognostic value incremental to NCEP with 1.85 and 2.47 hazard ratios, respectively. CONCLUSIONS: Measurement of LV mass can be obtained by cardiac CT images obtained at mid-diastasis. LV mass measurements obtained at mid-diastasis have prognostic value.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/mortalidade , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Multidetectores/métodos , Idoso , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/fisiopatologia , Estudos de Coortes , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Hipertrofia Ventricular Esquerda/fisiopatologia , Estimativa de Kaplan-Meier , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prognóstico , Modelos de Riscos Proporcionais , Curva ROC , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
19.
Eur J Nucl Med Mol Imaging ; 44(2): 259-266, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27752746

RESUMO

PURPOSE: The aim of this study was to evaluate the prognostic value of additional evaluation of left ventricular mechanical dyssynchrony (LVMD) by gated myocardial perfusion single-photon emission computed tomography (GMPS) in patients with acute myocardial infarction (MI) and multivessel disease. METHODS: One hundred and nine acute MI patients with >50 % stenosis in at least one non-culprit artery who underwent GMPS within 2 weeks were enrolled. All patients underwent successful revascularization of the culprit arteries. Those with previous MI, atrial fibrillation, or frequent ventricular premature complexes, cardiac devices, significant patient motion, or procedure-related events were excluded. Phase standard deviation (PSD) and phase histogram bandwidth (PBW) were measured for assessment of LVMD. Patients were followed up for a median of 26 months after index MI, for composite major adverse cardiac events (MACE), which consisted with all-cause death, unplanned hospitalization due to heart failure and severe ventricular arrhythmias (sustained ventricular tachycardia or ventricular fibrillation). Independent predictors of MACE were evaluated. RESULTS: MACE occurred in 22 patients (20 %). Stress PSD (53.3 ± 17.3° vs. 35.3 ± 18.9°; p <0.001), stress PBW (147.6 ± 54.6° vs. 96.8 ± 59.2°; p = 0.001) and resting PBW (126.8 ± 37.5° vs. 96.6 ± 48.9°; p = 0.001) were significantly higher in patients with MACE compared to those without. Multivariate analysis revealed that stress PSD ≥45.5° and stress PBW ≥126.0° were predictive of MACE, as well as suboptimal non-culprit artery revascularization (SNR) and renin-angiotensin system (RAS) blockade medication. Higher stress PSD and stress PBW were associated with poorer prognosis both in patients with and without SNR, and those with RAS blockade medication, but not in those without RAS blockade medication. CONCLUSIONS: LVMD measured by GMPS showed added prognostic value in acute MI with multivessel disease. GMPS could serve as a comprehensive evaluation imaging tool in patients with acute MI and multivessel disease.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Imagem do Acúmulo Cardíaco de Comporta/estatística & dados numéricos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Causalidade , Comorbidade , Intervalo Livre de Doença , Feminino , Imagem do Acúmulo Cardíaco de Comporta/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , República da Coreia/epidemiologia , Fatores de Risco , Sensibilidade e Especificidade , Volume Sistólico , Taxa de Sobrevida
20.
Pacing Clin Electrophysiol ; 39(11): 1213-1224, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27662633

RESUMO

BACKGROUND: The aim of the study was to evaluate the impact of idiopathic ventricular tachycardia and premature ventricular beats on cardiac function and dyssynchrony and to elucidate relationships between data of scintigraphic and intracardiac electrophysiology studies (EPSs). METHODS: The study comprised 64 patients with idiopathic ventricular arrhythmias (VAs; median age of 14 years ranging from 8 to 18 years). The control group comprised 20 patients (median age of 12 ranging from 7 to 16 years) without cardiac arrhythmias. EPS and radiofrequency ablation (RFA) procedure for VA were performed in 21 children according to indications. The functional state of both ventricles was assessed by gated blood pool single photon emission computer tomography (GBP-SPECT) before and after RFA in all patients. RESULTS: Patients with VA had local areas of asynchronous myocardial contraction (AMC). Compared with the control group, VA patients had significantly higher values of end-diastolic volume, end-systolic volume, and lower contractility indices. Negative association was found between total numbers of AMC areas and cardiac contractility indices. Ectopic foci localization, determined based on EPS data, was associated with AMC areas topography based on GBP-SPECT. RFA procedure significantly improved cardiac contractility indices; AMC areas completely disappeared or decreased compared with the preoperative conditions. CONCLUSION: In VA patients, AMC areas were localized mostly in the right ventricle. Comparison of the results of GBP-SPECT and EPS studies showed a relationship between AMC localizations and ectopic foci topography. The fact that AMC areas disappeared after RFA supports the hypothesis stating that the presence of AMC areas is a scintigraphic symptom of ectopic focus.


Assuntos
Coração/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Complexos Ventriculares Prematuros/fisiopatologia , Adolescente , Criança , Técnicas Eletrofisiológicas Cardíacas , Imagem do Acúmulo Cardíaco de Comporta , Hemodinâmica , Humanos , Contração Miocárdica/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA