Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 7(6): 1561-5, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17488051

RESUMO

Capacitance-voltage characteristics of individual germanium nanowire field effect transistors were directly measured and used to assess carrier mobility in nanowires for the first time, thereby removing uncertainties in calculated mobility due to device geometries, surface and interface states, and gate dielectric constants and thicknesses. Direct experimental evidence showed that surround-gated nanowire transistors exhibit higher capacitance and better electrostatic gate control than top-gated devices, and are the most promising structure for future high performance nanoelectronics.


Assuntos
Germânio/química , Nanotecnologia/instrumentação , Nanotubos/química , Nanotubos/ultraestrutura , Transistores Eletrônicos , Capacitância Elétrica , Instalação Elétrica/instrumentação , Transporte de Elétrons , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Nanotecnologia/métodos , Tamanho da Partícula
2.
Clin Infect Dis ; 17(1): 46-55, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8353245

RESUMO

We reviewed the data on 26 patients with permanent endocardial pacemakers who had 28 episodes of bacteremia to determine whether removal of the wire is required. Patients recovered completely from the first episode in seven of 20 cases of staphylococcal bacteremia and in six of six cases of nonstaphylococcal bacteremia (P = .015). Definitive cure was not achieved during the first episode in seven cases of staphylococcal bacteremia related to the pacing system when the wire was not withdrawn; however, cure was achieved in five of six cases when the whole pacemaker was removed (P < .01). The duration of treatment was longer for the patients from whom the wire was not removed during the first episode (P < .01). Whether cases of staphylococcal bacteremia were related to the pacing system or not, the rate of recovery of the responsible microorganism from the wires was similar for both groups of patients (six [82%] of seven and three [75%] of four, respectively). Nonstaphylococcal bacteremia was unrelated to the pacing system in five of six cases; these patients were all cured without removal of the wire.


Assuntos
Bacteriemia/etiologia , Marca-Passo Artificial/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Bacteriemia/diagnóstico , Bacteriemia/terapia , Instalação Elétrica/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA