Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur J Heart Fail ; 26(1): 18-33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38131233

RESUMO

Right-sided heart failure and tricuspid regurgitation are common and strongly associated with poor quality of life and an increased risk of heart failure hospitalizations and death. While medical therapy for right-sided heart failure is limited, treatment options for tricuspid regurgitation include surgery and, based on recent developments, several transcatheter interventions. However, the patients who might benefit from tricuspid valve interventions are yet unknown, as is the ideal time for these treatments given the paucity of clinical evidence. In this context, it is crucial to elucidate aetiology and pathophysiological mechanisms leading to right-sided heart failure and tricuspid regurgitation in order to recognize when tricuspid regurgitation is a mere bystander and when it can cause or contribute to heart failure progression. Notably, early identification of right heart failure and tricuspid regurgitation may be crucial and optimal management requires knowledge about the different mechanisms and causes, clinical course and presentation, as well as possible treatment options. The aim of this clinical consensus statement is to summarize current knowledge about epidemiology, pathophysiology and treatment of tricuspid regurgitation in right-sided heart failure providing practical suggestions for patient identification and management.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Qualidade de Vida , Valva Tricúspide/cirurgia , Resultado do Tratamento
3.
J Invasive Cardiol ; 35(3): E122-E125, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36607792

RESUMO

BACKGROUND: Disparities between thermodilution (TD) and Fick measurements of cardiac index (CI) are common in real-world clinical practice. Published studies about the effect of tricuspid regurgitation (TR) on TD are small and describe conflicting results. We tested the correlation between TD and Fick across a wide range of TR severity, in a larger group of patients undergoing right heart catheterization (RHC). We aimed to determine if TD is an acceptable alternative to Fick in patients with TR in clinical practice. METHODS: We retrospectively evaluated patients undergoing RHC at a single center over a 10-month period, and included those with recent (<90 days) echocardiograms. TD was measured during RHC and Fick was calculated using estimated oxygen consumption. The primary outcome was the correlation between TD and Fick CIs. We performed regression modeling to evaluate predictors of the difference between TD and Fick. RESULTS: A total of 349 patients were included, 40% of whom had at least moderate TR. The correlation between TD and Fick was strong (r=0.765) and did not significantly differ in those with none to mild TR (r=0.73) and those with moderate to severe TR (r=0.80). Atrial fibrillation or atrial flutter was the only variable significantly associated with the difference between CI by Fick and TD (P=.04). CONCLUSION: The correlation between TD and Fick was strong and unaffected by TR severity.


Assuntos
Termodiluição , Insuficiência da Valva Tricúspide , Humanos , Termodiluição/métodos , Estudos Retrospectivos , Insuficiência da Valva Tricúspide/diagnóstico , Débito Cardíaco , Cateterismo Cardíaco
5.
J Artif Organs ; 24(2): 217-224, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33483881

RESUMO

PURPOSE: The purpose of this study was to develop a simple and effective percutaneous approach to create tricuspid regurgitation in swine. METHODS: Eleven pigs (71.68 ± 7.70 kg, 3 male) were involved in this study. A grasping forceps was introduced into the right ventricle through a steerable sheath under fluoroscopic guidance and used to disrupt the tricuspid valve apparatus by avulsing leaflet or chordae tendineae repeatedly. Transthoracic echocardiography and right ventricular angiography were used to evaluate the degree of tricuspid regurgitation created. RESULTS: Ten of the 11 pigs (90.91%) achieved severe tricuspid regurgitation and 1 (9.09%) obtained moderate tricuspid regurgitation immediately after the procedure. Heart rate of the pigs significantly increased immediately after tricuspid regurgitation creation compared to baseline (88.64 ± 23.24 vs. 76.00 ± 15.30 bpm, P = 0.02), but recovered to normal level at one month follow-up (77.09 ± 11.97 bpm, P = 0.85). The right atrium, tricuspid valve annulus, and right ventricle dilated obviously one month after tricuspid regurgitation creation (dimension changes: 3.01 ± 0.35 vs. 3.56 ± 0.40 cm, P = 0.02; 2.92 ± 0.36 vs. 3.37 ± 0.39 cm, P = 0.01; 3.06 ± 0.42 vs. 3.60 ± 0.47 cm, P = 0.03 respectively). Autopsy findings showed that rupture of leaflet and/or chordae tendineae finally led to the tricuspid regurgitation. CONCLUSIONS: Severe tricuspid regurgitation can be created by a simple and effective percutaneous approach with a grasping forceps in swine model and right heart dilation can be observed consistently at one-month follow-up. This model will be valuable in pre-clinical studies for developing new tricuspid valve repair or replacement technique to treat severe tricuspid regurgitation.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Modelos Animais de Doenças , Suínos , Insuficiência da Valva Tricúspide/patologia , Animais , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/patologia , Cordas Tendinosas/fisiopatologia , Ecocardiografia , Procedimentos Endovasculares/métodos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/patologia , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/fisiopatologia
6.
Am J Cardiol ; 132: 119-125, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32741538

RESUMO

It is well known that some patients present with "more than severe" tricuspid regurgitation (TR). We aimed to assess the prognosis of these very severe TR patients. We defined very severe TR using 3 simple echocardiographic parameters: a coaptation gap≥10mm, a laminar TR flow and a systolic reversal of the hepatic vein flow. We included 259 consecutive patients (76 ± 13 years; 46% men) with moderate-to-severe TR (n = 114) and severe TR (n = 145). The primary end point was the combination of hospitalisation for right heart failure (RHF) and cardiovascular mortality. Median follow-up was 24(7 to 47) months. In patients with severe TR, 52 (36%) met the definition of very severe TR. These patients were younger, had more history of RHF and were more frequently treated with loop diuretics than those with moderate-to-severe TR (all p < 0.001). Four-year event-free survival rates were 68 ± 5%, for moderate-to-severe TR, 48 ± 6% for severe TR and only 35 ± 7% for very-severe TR (p < 0.001). On multivariable analysis, after adjustment for outcome predictors including age, comorbidity, RHF, TR etiology, left and right ventricular dysfunction, and tricuspid valve surgery, patients with very severe TR had a worsened prognosis than those with moderate-to-severe TR (Adjusted Hazard Ratio [95% Confidence Interval] = 2.43 [1.18 to 5.53]; p = 0.002) and than those with severe TR (Adjusted Hazard Ratio [95% Confidence Interval] = 2.23 [1.06 to 5.56]; p = 0.015). In conclusion, very severe TR is frequent in patients with severe TR, corresponds to a more advanced stage of the disease and is associated with poor outcomes. Therefore, the use of a 5-grade classification of TR severity is justified in routine clinical practice. (ID-RCB: 2017-A03233-50).


Assuntos
Ecocardiografia Doppler/métodos , Insuficiência da Valva Tricúspide/classificação , Valva Tricúspide/diagnóstico por imagem , Idoso , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/diagnóstico
7.
ESC Heart Fail ; 7(4): 1653-1663, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32372555

RESUMO

AIMS: Improved risk stratification is of value for decision making in pulmonary arterial hypertension (PAH). Right heart catheterization combined with quantitative tricuspid regurgitation (TR) by cardiovascular magnetic resonance (CMR) may provide this. The aims were to study: (i) to what extent quantitative TR is associated with event-free survival; (ii) how quantitative TR is related to known prognostic markers in PAH; and (iii) to what extent quantitative TR and right atrial pressure determine right atrial dilation. METHODS AND RESULTS: Fifty patients (63 ± 17 years) with PAH referred for CMR were included. Volumes and pulmonary artery flow by CMR and pressure and vascular resistance by right heart catheterization were obtained. Composite outcome was lung transplantation or death. Four transplantations and 27 deaths occurred over a median of 2.7 years. A trend towards higher hazard ratio was shown for TR volume (TRV; 2.1, 95% CI 1.0-4.4) and TR fraction (TR%; 1.6, 95% CI 0.8-3.3) above median. TRV and TR% correlated with right ventricular (RV) end-diastolic (TRV r = 0.50; TR% r = 0.39) and end-systolic (TRV r = 0.35; TR% r = 0.30) volumes, pulmonary vascular resistance (TRV r = 0.28; TR% r = 0.43), N terminal pro brain natriuretic peptide (TRV r = 0.65; TR% r = 0.68), cardiac index (TRV r = -0.32; TR% r = -0.54), pulmonary artery stroke volume (TRV r = -0.32; TR% r = -0.58) and effective RV ejection fraction by pulmonary artery quantitative flow (TRV r = -0.56; TR% r = -0.69), but not RVEF. Both TR% and right atrial pressure determined right atrial volumes (r2  = 0.38; r2  = 0.48). CONCLUSIONS: A clear trend towards worse outcome with larger TRV or TR% was shown; however, the number of events was insufficient for significant outcome differences. Prognostic value of quantitative TR should be investigated in a larger multicentre cohort. Effective RV ejection fraction may be considered an improved measure of RV function in PAH.


Assuntos
Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Espectroscopia de Ressonância Magnética , Medição de Risco , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/etiologia
8.
Prog Cardiovasc Dis ; 62(6): 452-458, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31669497

RESUMO

Echocardiographic imaging is an integral part of characterizing patients with tricuspid regurgitation (TR) and helps in determining the timing of intervention and procedural guidance for transcatheter interventions. The rapid advances in both two-dimensional and three-dimensional imaging however have facilitated the development and deployment of novel transcatheter devices to address the unmet need for patients with symptomatic severe TR.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Tricúspide/anatomia & histologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
9.
Prog Cardiovasc Dis ; 62(6): 447-451, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31707061

RESUMO

Tricuspid regurgitation (TR) has long been a forgotten valve disease of benign reputation. However, TR deserves higher attention and represents a growing public health crisis. Indeed, recent epidemiological data suggest that 1.6 million US residents are affected by moderate or severe TR. Furthermore, large recent cohorts demonstrate that higher degrees of TR are associated with considerable excess mortality, independent of all background clinical and hemodynamic contexts. Finally, analysis of recent cohorts also shows that >90% of patients with moderate or severe TR are never offered surgical treatment and remain untreated. Therefore, TR is frequent, severely impacts outcomes, and is rarely treated, justifying the development of new strategies and methods for its treatment.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Administração dos Cuidados ao Paciente/métodos , Insuficiência da Valva Tricúspide , Necessidades e Demandas de Serviços de Saúde , Humanos , Prevalência , Índice de Gravidade de Doença , Tempo para o Tratamento , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/terapia
10.
Echocardiography ; 36(11): 1979-1988, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31633241

RESUMO

BACKGROUND: Right ventricle (RV) evaluation requires dedicated imaging to achieve a comprehensive functional and anatomical assessment. Right ventricular imaging could be technically difficult which results in suboptimal visibility and inconsistent assessment between observers. The aim of this study was to assess feasibility and the additive value of contrast enhancement for right ventricular evaluation. METHODS: Eighty patients referred for clinically indicated echocardiography studies were included. Patients with irregular rhythms were excluded. Dedicated RV-focused view was attained; RV dimensions measured, and RV segment visualization and wall motion were assessed with and without contrast enhancement. Paired sample t test was used to compare continuous variables, Wilcoxon signed-rank test to compare segments visualization on enhanced versus (vs) nonenhanced images, and Cohen kappa coefficient to assess the agreement of wall motion between two observers. Reproducibility was measured by the absolute mean difference method. RESULTS: A total of 240 total segments of 80 patients were analyzed, and 178 (74%) were visible on unenhanced while 221 (92%) on enhanced images, P < .05. Further, RV measurements on enhanced images were consistently larger on RV focused, SAX, and RVOT. Inter- and intra-observer reproducibility showed a higher reproducibility with a lower bias on enhanced images. Absolute agreement on RV segmental wall motion between two independent observers was higher on enhanced images. Percent agreement was 78% on UE vs 89% on CE. CONCLUSION: Contrast RV imaging is feasible and improves RV segment visualization and inter-observer agreement. Compared with unenhanced images, RV measurements on contrast images are larger and more reproducible with lower bias.


Assuntos
Meios de Contraste/farmacologia , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico , Função Ventricular Direita/fisiologia , Idoso , Estudos de Viabilidade , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Tamanho do Órgão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Insuficiência da Valva Tricúspide/fisiopatologia
11.
J Am Soc Echocardiogr ; 32(2): 238-247, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30459122

RESUMO

BACKGROUND: Evaluation of the tricuspid annulus is crucial for the decision making at the time of left heart surgery. Current recommendations for tricuspid valve repair are based on two-dimensional (2D) transthoracic echocardiography (TTE), despite the known underestimation compared with three-dimensional (3D) echocardiography. However, little is known about the differences in 3D tricuspid annular (TA) sizing using TTE versus transesophageal echocardiography (TEE). The aims of this study were to (1) compare 2D and 3D TA measurements performed with both TTE and TEE and (2) compare two 3D methods for TA measurements: multiplanar reconstruction (MPR) and dedicated software (DS) designed to take into account TA nonplanarity. METHODS: Seventy patients underwent 2D and 3D TTE and TEE. Two-dimensional images were used to measure TA diameter from apical four-chamber, right ventricular-focused (TTE), and midesophageal four-chamber (TEE) views. Three-dimensional full-volume data sets were analyzed using both MPR and DS, to obtain major and minor axes, perimeter, and area. Intertechnique agreement was assessed using Bland-Altman analysis. RESULTS: Measurements on 2D TTE and TEE, which were view dependent, underestimated TA major dimensions in all views compared with 3D values, irrespective of the 3D method. MPR and DS measurements were significantly different, with DS resulting in larger values for all parameters, irrespective of approach. No differences were found between 3D TTE and 3D TEE for both MPR and DS. CONCLUSIONS: Our findings highlight the need for methodology that respects the 3D geometry of the tricuspid annulus, including its nonplanarity, which cannot be accurately assessed from 2D images and is not equally taken into account by different 3D measurement methodologies. Accordingly, a 3D cutoff value for TA enlargement needs to be established and is likely to be larger than the guideline-recommended 2D-based 40-mm cutoff. Importantly, noninvasive 3D TTE can be used instead of 3D TEE because TA measurements are not different.


Assuntos
Tomada de Decisões , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
12.
J Am Soc Echocardiogr ; 31(11): 1190-1202.e3, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30269909

RESUMO

BACKGROUND: Tricuspid valve imaging is frequently challenging and requires the use of multiple modalities. Knowledge of limitations and methodologic discrepancies among different imaging techniques is crucial for planning transcatheter valve interventions. METHODS: Thirty-eight patients with severe symptomatic tricuspid regurgitation were included in this retrospective analysis. Tricuspid annulus (TA) measurements were made during mid-diastole using three-dimensional (3D) transthoracic echocardiographic direct planimetry (TTE_direct) and transesophageal echocardiographic direct planimetry (TEE_direct). Moreover, a semiautomated software was used to generate two-dimensional (2D) and 3D perimeter and area on transesophageal echocardiography (TEE) images. Both methods were compared with direct computed tomographic planimetry (CT_direct) and cubic spline interpolation (CT_indirect). The different TA values were used to calculate the effective regurgitant orifice area and compared with 3D Doppler vena contracta area. For tricuspid valve area TEE_direct and CT_direct as well as CT_indirect were measured. RESULTS: Agreement between TEE and computed tomography (CT) for TA sizing was obtained using semiautomated methods (3D TEE_indirect and CT_indirect). TTE_direct was overall less reliable compared with CT. TA area quantified by TEE_direct was 25% (difference 305 ± 238 mm2, P < .001, R = 0.9) and 19% (166 ± 247 mm2, P < .001, R = 0.89) smaller compared with CT_direct and CT_indirect, respectively. TA perimeter measurements by TEE_direct differed by 11% compared with CT_direct (12 ± 11 mm, P < .001, R = 0.87) and 3D CT_indirect (12 ± 11 mm, P < .001, R = 0.88), and 9% compared with 2D CT_indirect (7 ± 11 mm, P = .002, R = 0.87). TEE_direct of the TA allows the most accurate calculation of effective regurgitant orifice area compared with 3D vena contracta area (-8 ± 62 mm2, P = .50, R = 0.85). Tricuspid valve area by CT_indirect best correlated with conventional TEE_direct (80 ± 250 mm2, P = .11, R = 0.80). CONCLUSIONS: In patients with severe tricuspid regurgitation, semiautomated indirect planimetry results in high agreement between TEE and CT for TA sizing and measurement of the tricuspid valve area. TEE_direct of the TA allows the most accurate measurement of diastolic stroke volume for the calculation of regurgitation severity compared with 3D vena contracta area.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Tomografia Computadorizada Multidetectores/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
13.
Interv Cardiol Clin ; 7(3): 379-386, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29983149

RESUMO

The tricuspid valve is a highly complex structure, with variability in the number of leaflets and scallops. The mechanism of regurgitation is multifactorial in etiology, a mix of functional and degenerative tricuspid regurgitation. Iatrogenic tricuspid regurgitation is becoming more common secondary to pacemaker wire impingement of leaflet function and coaptation. Echocardiographic imaging of the tricuspid valve is particularly challenging given its anatomic location and other interfering structures, including pacemaker wires. Preprocedural planning and intraprocedural guidance for transcatheter intervention relies on a comprehensive understanding of tricuspid anatomy and the use of 3-dimensional transesophageal echocardiography. The incorporation of computed tomography and cardiac magnetic resonance imaging likely will provide increasing accuracy and optimization of procedural success.


Assuntos
Cateterismo Cardíaco/instrumentação , Imagem Multimodal/métodos , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Bioprótese , Cateterismo Cardíaco/métodos , Anuloplastia da Valva Cardíaca/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Previsões , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Angiografia por Ressonância Magnética/métodos , Impressão Tridimensional , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia
14.
J Cardiovasc Magn Reson ; 16: 23, 2014 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-24625242

RESUMO

BACKGROUND: The purpose of this study was to quantify right (RV) and left (LV) ventricular function, pulmonary artery flow (QP), tricuspid valve regurgitation velocity (TRV), and aorta flow (QS) from a single 4D flow cardiovascular magnetic resonance (CMR) (time-resolved three-directionally motion encoded CMR) sequence in a canine model of acute thromboembolic pulmonary hypertension (PH). METHODS: Acute PH was induced in six female beagles by microbead injection into the right atrium. Pulmonary arterial (PAP) and pulmonary capillary wedge (PCWP) pressures and cardiac output (CO) were measured by right heart catheterization (RHC) at baseline and following induction of acute PH. Pulmonary vascular resistance (PVRRHC) was calculated from RHC values of PAP, PCWP and CO (PVRRHC = (PAP-PCWP)/CO). Cardiac magnetic resonance (CMR) was performed on a 3 T scanner at baseline and following induction of acute PH. RV and LV end-diastolic (EDV) and end-systolic (ESV) volumes were determined from both CINE balanced steady-state free precession (bSSFP) and 4D flow CMR magnitude images. QP, TRV, and QS were determined from manually placed cutplanes in the 4D flow CMR flow-sensitive images in the main (MPA), right (RPA), and left (LPA) pulmonary arteries, the tricuspid valve (TRV), and aorta respectively. MPA, RPA, and LPA flow was also measured using two-dimensional flow-sensitive (2D flow) CMR. RESULTS: Biases between 4D flow CMR and bSSFP were 0.8 mL and 1.6 mL for RV EDV and RV ESV, respectively, and 0.8 mL and 4 mL for LV EDV and LV ESV, respectively. Flow in the MPA, RPA, and LPA did not change after induction of acute PAH (p = 0.42-0.81). MPA, RPA, and LPA flow determined with 4D flow CMR was significantly lower than with 2D flow (p < 0.05). The correlation between QP/TRV and PVRRHC was 0.95. The average QP/QS was 0.96 ± 0.11. CONCLUSIONS: Using both magnitude and flow-sensitive data from a single 4D flow CMR acquisition permits simultaneous quantification of cardiac function and cardiopulmonary hemodynamic parameters important in the assessment of PH.


Assuntos
Hipertensão Pulmonar/diagnóstico , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Embolia Pulmonar/diagnóstico , Resistência Vascular , Função Ventricular Esquerda , Função Ventricular Direita , Doença Aguda , Animais , Aorta/fisiopatologia , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco , Modelos Animais de Doenças , Cães , Estudos de Viabilidade , Feminino , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Valor Preditivo dos Testes , Embolia Pulmonar/etiologia , Embolia Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
15.
Interact Cardiovasc Thorac Surg ; 16(6): 743-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23466952

RESUMO

OBJECTIVES: Functional tricuspid regurgitation (FTR) is generally caused by the dilation of the tricuspid annulus (TA) and the tethering of tricuspid leaflets; however, it also occurs in patients without dilatation of the TA. The aim of this study was to develop and to use a four-dimensional tracking system, utilizing cardiac magnetic resonance imaging (MRI), and to assess TA flexibility in patients with early FTR without right ventricle dilation as a preliminary investigation for the mechanism of early FTR. METHODS: The structure and movement of the TA were examined in 20 healthy subjects and 19 FTR patients whose right ventricle was not dilated. We analysed the short axis and longitudinal movement of a mid-septal point (S), a mid-lateral point (L), a mid-anterior point (A) and a mid-posterior point (P) on the TA throughout the cardiac cycle. The tethering distance of the tricuspid leaflets and the integrated orbiting volume of the TA were also measured. RESULTS: The TA area (mm(2)) and AP and LS distances (mm) did not differ significantly between the two groups, but the longitudinally moving distances (mm) of the four points were significantly shorter in patients with FTR than in healthy subjects. Also, the mean tethering distance (mm) was significantly longer in patients with FTR than in healthy subjects (9.0 ± 1.5 vs 4.0 ± 1.3, respectively; P < 0.001), and the integrated volume (mm(3)) of the annular moving track, throughout the cardiac cycle, was significantly larger in healthy subjects than in patients with FTR (40 428 ± 10 951 vs 22 967 ± 6079, P < 0.001). CONCLUSIONS: The longitudinal flexibility of the TA in FTR patients was significantly less than that in the healthy subjects, and the tethering of the tricuspid leaflets occurred in FTR patients despite the absence of TA and RV dilation, which can be one triggering factor of early FTR. Four-dimensional geometric assessment, using cardiac MRI and the tracking program that we have developed, is capable of determining TA structure and flexibility.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Fenômenos Biomecânicos , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Insuficiência da Valva Tricúspide/fisiopatologia , Adulto Jovem
16.
Eur Heart J Cardiovasc Imaging ; 14(10): 986-95, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23341146

RESUMO

AIMS: To explore the potentiality of cardiovascular magnetic resonance (CMR) in the quantitative evaluation of mitral valve annulus (MVA) and tricuspid valve annulus (TVA) morphology and dynamics. METHODS AND RESULTS: CMR was performed in 13 normal subjects and 9 patients with mitral (n = 7) or tricuspid regurgitation (n = 2), acquiring cine-images in 18 radial long-axis planes passing through the middle of MVA or TVA. A novel algorithm was used to obtain dynamic three-dimensional (3D) reconstruction of MVA and TVA. Analysis was feasible in all cases, allowing accurate 3D annular reconstruction and tracking. The 3D area increased from systole [MVA, median = 10.0 cm(2) (first quartile = 8.6, third quartile = 11.4); TVA, 11.2 cm(2) (8.8-13.2)] to diastole [MVA, 10.6 cm(2) (9.4, 11.7); TVA, 11.9 cm(2) (9.2-13.5)], with TVA larger than MVA. While the longest diameter showed similar systolic and diastolic values, the shortest diameter elongated from systole [MVA, 30 mm (29-33); TVA, 33 mm (31-36)] to diastole [MVA, 31 mm (29-32); TVA, 36 mm (33-39)]. Also, TVA became more circular than MVA. TVA showed lower peak systolic excursion in the septal [15.9 mm (13.0-18.5)] and anterior regions [17.9 mm (12.2-20.7)] compared with the posterior [21.9 mm (18.6-24.0)] segment. Values in MVA were smaller than in TVA, slightly higher in anterior [11.2 mm (9.5-13.0)] than in posterior [12.4 mm (10.2-14.6)] segments. Valvular regurgitation was associated with enlarged, flattened, and more circular annuli. CONCLUSION: The applied method was feasible and accurate in normal and regurgitant valves, and may potentially have an impact on diagnosis, improvement of surgical techniques and design of annular prostheses.


Assuntos
Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico , Valva Mitral/anatomia & histologia , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/anatomia & histologia , Adulto , Anuloplastia da Valva Cardíaca/métodos , Estudos de Casos e Controles , Cordas Tendinosas/anatomia & histologia , Cordas Tendinosas/cirurgia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Valores de Referência , Índice de Gravidade de Doença , Estatísticas não Paramétricas , Valva Tricúspide/patologia , Valva Tricúspide/cirurgia
17.
J Thorac Cardiovasc Surg ; 146(5): 1126-1132.e10, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23010580

RESUMO

OBJECTIVES: To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. METHODS: From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+ (100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. RESULTS: In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+ or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. CONCLUSIONS: In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant tricuspid valve repair effectively and durably eliminated severe tricuspid regurgitation and improved right ventricular function toward normal, supporting an aggressive approach to important functional tricuspid regurgitation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Humanos , Modelos Lineares , Modelos Logísticos , Masculino , Cadeias de Markov , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Método de Monte Carlo , Análise Multivariada , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia
18.
Invest Radiol ; 44(10): 669-75, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19724233

RESUMO

OBJECTIVES: To validate 3-dimensional (3D) 3-directional velocity-encoded (VE) magnetic resonance imaging (MRI) for flow assessment through all 4 heart valves simultaneously with retrospective valve-tracking during off-line analysis in healthy volunteers and in patients with valvular regurgitation. MATERIAL AND METHODS: Three-dimensional 3-directional VE MRI was performed in 22 healthy volunteers and in 29 patients with ischemic cardiomyopathy who were suspected of valvular regurgitation and net flow volumes through the 4 heart valves were compared. Furthermore, the analysis was repeated for each valve in 10 healthy volunteers and in 10 regurgitant valves to assess intra- and interobserver agreement for assessment of respectively net flow volumes and regurgitation fraction. RESULTS: In healthy volunteers, the average net flow volume through the mitral valve, tricuspid valve, aortic valve, and pulmonary valve was 85 +/- 20 mL, 85 +/- 21 mL, 83 +/- 19 mL, 82 +/- 21 mL, respectively. Strong correlations between net flow volumes through the 4 heart valves were observed (intraclass correlation coefficients [ICC] 0.93-0.95) and the coefficient of variance (CV) was small (6%-9%). The repeated analysis by the same observer and by a second observer yielded good agreement for measurement of net flow volumes (ICC: 0.93-0.99 and CV: 3%-7%). Strong correlations between the net flow volumes through the 4 heart valves were also observed in the patients with valvular regurgitation (ICC: 0.85-0.95 and CV: 7%-18%). The average net flow volume through the mitral valve, tricuspid valve, aortic valve, and pulmonary valve was 63 +/- 20 mL, 63 +/- 20 mL, 63 +/- 20 mL, 63 +/- 20 mL, respectively. Furthermore, the intra- and interobserver agreement for assessment of regurgitation fraction was good (ICC: 0.86 and 0.85, CV: 12% and 13%). CONCLUSIONS: Flow assessment using 3D 3-directional VE MR with retrospective valve-tracking during off-line analysis enables accurate quantification of net flow volumes through 4 heart valves within a single acquisition in healthy volunteers and in patients with valvular regurgitation.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Tricúspide/fisiopatologia , Adulto , Insuficiência da Valva Aórtica/diagnóstico , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Pulmonar/diagnóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Insuficiência da Valva Tricúspide/diagnóstico
19.
Clin Radiol ; 64(8): 761-6, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19589414

RESUMO

Carcinoid disease arises from a low-grade neuroendocrine tumour derived from serotonin-producing enterochromaffin cells. It is the most common tumour affecting the small bowel. The majority of patients who progress to carcinoid syndrome develop cardiac disease selectively involving the right side of the heart, whereas left heart disease is unusual. The most common cause of death is dilatation and dysfunction of the right ventricle. Right ventricular dysfunction is largely secondary to pathological endocardial fibrosis of the tricuspid and pulmonary valves, presenting with regurgitation and stenosis. Average survival falls to only 11 months with the onset of symptoms, but recent evidence suggests that survival can be improved by early surgery in selected individuals. This article reviews the particular role that cardiovascular magnetic resonance imaging has in the management of carcinoid heart disease.


Assuntos
Doença Cardíaca Carcinoide/diagnóstico , Doenças das Valvas Cardíacas/complicações , Disfunção Ventricular Direita/diagnóstico , Doença Cardíaca Carcinoide/complicações , Doenças das Valvas Cardíacas/diagnóstico , Humanos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/complicações , Insuficiência da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/complicações , Estenose da Valva Pulmonar/diagnóstico , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico , Estenose da Valva Tricúspide/complicações , Estenose da Valva Tricúspide/diagnóstico , Disfunção Ventricular Direita/etiologia
20.
Heart Fail Clin ; 5(3): 389-400, vi-vii, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19564015

RESUMO

Cardiovascular magnetic resonance is able to provide a comprehensive assessment of valvular and hemodynamic function, including quantification of valve regurgitation and other flows, and accurate cardiac volumes and mass for assessing the effect on both ventricles. Combined with the ability to image all areas of the heart (including difficult areas, such as the right ventricle and pulmonary veins), it is an ideal technique for investigating patients who have heart failure in whom these areas need to be examined.


Assuntos
Doenças das Valvas Cardíacas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Anastomose Cirúrgica , Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico , Arritmias Cardíacas/diagnóstico , Criança , Pré-Escolar , Testes de Função Cardíaca/métodos , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Insuficiência da Valva Mitral/diagnóstico , Estenose da Valva Mitral/diagnóstico , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Estenose da Valva Tricúspide/diagnóstico , Função Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA