Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Med Biol Eng Comput ; 62(5): 1475-1490, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38267740

RESUMO

Fatigue deteriorates the performance of a brain-computer interface (BCI) system; thus, reliable detection of fatigue is the first step to counter this problem. The fatigue evaluated by means of electroencephalographic (EEG) signals has been studied in many research projects, but widely different results have been reported. Moreover, there is scant research when considering the fatigue on steady-state visually evoked potential (SSVEP)-based BCI. Therefore, nowadays, fatigue detection is not a completely solved topic. In the current work, the issues found in the literature that led to the differences in the results are identified and saved by performing a new experiment on an SSVEP-based BCI system. The experiment was long enough to produce fatigue in the users, and different SSVEP stimulation ranges were used. Additionally, the EEG features commonly reported in the literature (EEG rhythms powers, SNR, etc.) were calculated as well as newly proposed features (spectral features and Lempel-Ziv complexity). The analysis was carried out on O1, Oz and O2 channels. This work found a tendency of displacement from high-frequency rhythms to low-frequency ones, and thus, better EEG features should present a similar behaviour. Then, the 'relative power' of EEG rhythms, the rates (θ + α)/ß, α/ß and θ/ß, some spectral features (central and mean frequencies, asymmetry and kurtosis coefficients, etc.) and Lempel-Ziv complexity are proposed as reliable EEG features for fatigue detection. Hence, this set of features may be used to construct a more trustworthy fatigue index.


Assuntos
Astenopia , Interfaces Cérebro-Computador , Humanos , Potenciais Evocados Visuais , Estimulação Luminosa , Potenciais Evocados , Eletroencefalografia/métodos , Algoritmos
2.
IEEE Trans Biomed Eng ; 71(3): 792-802, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37747857

RESUMO

OBJECTIVE: Past research in Brain-Computer Interfaces (BCI) have presented different decoding algorithms for different modalities. Meanwhile, highly specific decision making processes have been developed for some of these modalities, while others lack such a component in their classic pipeline. The present work proposes a model based on Partially Observable Markov Decission Process (POMDP) that works as a high-level decision making framework for three different active/reactive BCI modalities. METHODS: We tested our approach on three different BCI modalities using publicly available datasets. We compared the general POMDP model as a decision making process with state of the art methods for each BCI modality. Accuracy, false positive (FP) trials, no-action (NA) trials and average decision time are presented as metrics. RESULTS: Our results show how the presented POMDP models achieve comparable or better performance to the presented baseline methods, while being usable for the three proposed experiments without significant changes. Crucially, it offers the possibility of taking no-action (NA) when the decoding does not perform well. CONCLUSION: The present work implements a flexible POMDP model that acts as a sequential decision framework for BCI systems that lack such a component, and perform comparably to those that include it. SIGNIFICANCE: We believe the proposed POMDP framework provides several interesting properties for future BCI developments, mainly the generalizability to any BCI modality and the possible integration of other physiological or brain data pipelines under a unified decision-making framework.


Assuntos
Interfaces Cérebro-Computador , Benchmarking , Algoritmos , Cadeias de Markov , Encéfalo/fisiologia , Eletroencefalografia/métodos
3.
J Neural Eng ; 20(6)2023 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-38128128

RESUMO

Objective.While electroencephalography (EEG)-based brain-computer interfaces (BCIs) have many potential clinical applications, their use is impeded by poor performance for many users. To improve BCI performance, either via enhanced signal processing or user training, it is critical to understand and describe each user's ability to perform mental control tasks and produce discernible EEG patterns. While classification accuracy has predominantly been used to assess user performance, limitations and criticisms of this approach have emerged, thus prompting the need to develop novel user assessment approaches with greater descriptive capability. Here, we propose a combination of unsupervised clustering and Markov chain models to assess and describe user skill.Approach.Using unsupervisedK-means clustering, we segmented the EEG signal space into regions representing pattern states that users could produce. A user's movement through these pattern states while performing different tasks was modeled using Markov chains. Finally, using the steady-state distributions and entropy rates of the Markov chains, we proposed two metricstaskDistinctandrelativeTaskInconsistencyto assess, respectively, a user's ability to (i) produce distinct task-specific patterns for each mental task and (ii) maintain consistent patterns during individual tasks.Main results.Analysis of data from 14 adolescents using a three-class BCI revealed significant correlations between thetaskDistinctandrelativeTaskInconsistencymetrics and classification F1 score. Moreover, analysis of the pattern states and Markov chain models yielded descriptive information regarding user performance not immediately apparent from classification accuracy.Significance.Our proposed user assessment method can be used in concert with classifier-based analysis to further understand the extent to which users produce task-specific, time-evolving EEG patterns. In turn, this information could be used to enhance user training or classifier design.


Assuntos
Interfaces Cérebro-Computador , Adolescente , Humanos , Cadeias de Markov , Eletroencefalografia/métodos , Imagens, Psicoterapia , Movimento , Encéfalo
4.
Artigo em Inglês | MEDLINE | ID: mdl-37856256

RESUMO

The aim of this study is to estimate the maximum power consumption that guarantees the thermal safety of a skull unit (SU). The SU is part of a fully-implantable bi-directional brain computer-interface (BD-BCI) system that aims to restore walking and leg sensation to those with spinal cord injury (SCI). To estimate the SU power budget, we created a bio-heat model using the finite element method (FEM) implemented in COMSOL. To ensure that our predictions were robust against the natural variation of the model's parameters, we also performed a sensitivity analysis. Based on our simulations, we estimated that the SU can nominally consume up to 70 mW of power without raising the surrounding tissues' temperature above the thermal safety threshold of 1°C. When considering the natural variation of the model's parameters, we estimated that the power budget could range between 47 and 81 mW. This power budget should be sufficient to power the basic operations of the SU, including amplification, serialization and A/D conversion of the neural signals, as well as control of cortical stimulation. Determining the power budget is an important specification for the design of the SU and, in turn, the design of a fully-implantable BD-BCI system.


Assuntos
Interfaces Cérebro-Computador , Humanos , Temperatura Alta , Crânio , Cabeça , Próteses e Implantes
5.
BMC Res Notes ; 16(1): 288, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875937

RESUMO

OBJECTIVE: Hypnosis can be an effective treatment for many conditions, and there have been attempts to develop instrumental approaches to continuously monitor hypnotic state level ("depth"). However, there is no method that addresses the individual variability of electrophysiological hypnotic correlates. We explore the possibility of using an EEG-based passive brain-computer interface (pBCI) for real-time, individualised estimation of the hypnosis deepening process. RESULTS: The wakefulness and deep hypnosis intervals were manually defined and labelled in 27 electroencephalographic (EEG) recordings obtained from eight outpatients after hypnosis sessions. Spectral analysis showed that EEG correlates of deep hypnosis were relatively stable in each patient throughout the treatment but varied between patients. Data from each first session was used to train classification models to continuously assess deep hypnosis probability in subsequent sessions. Models trained using four frequency bands (1.5-45, 1.5-8, 1.5-14, and 4-15 Hz) showed accuracy mostly exceeding 85% in a 10-fold cross-validation. Real-time classification accuracy was also acceptable, so at least one of the four bands yielded results exceeding 74% in any session. The best results averaged across all sessions were obtained using 1.5-14 and 4-15 Hz, with an accuracy of 82%. The revealed issues are also discussed.


Assuntos
Interfaces Cérebro-Computador , Hipnose , Humanos , Hipnóticos e Sedativos , Eletroencefalografia/métodos
6.
Sensors (Basel) ; 23(13)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37447780

RESUMO

Objective: We designed and validated a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain-computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user's hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An inertial measurement unit (IMU) provides monitoring of head movements. The EEG amplifier operates with 24-bit resolution up to 500 Hz sampling frequency and can communicate with other devices using 802.11 b/g/n WiFi. It has high signal-to-noise ratio (SNR) and common-mode rejection ratio (CMRR) (121 dB and 110 dB, respectively) and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as a backend coding language and JavaScript (JS), Cascading Style Sheets (CSS), and HyperText Markup Language (HTML) as front-end coding languages and includes training and optimization of support vector machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human-subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation and provides proof-of-concept validation for the device's use at both the clinic and at home. Significance: The usability, interoperability, portability, reliability, and programmability of the proposed wireless closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.


Assuntos
Interfaces Cérebro-Computador , Humanos , Reprodutibilidade dos Testes , Eletroencefalografia , Encéfalo , Movimentos Oculares
7.
Appl Ergon ; 111: 104028, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37148587

RESUMO

Brain-computer interface (BCI) technologies are progressing rapidly and may eventually be implemented widely within society, yet their risks have arguably not yet been comprehensively identified, nor understood. This study analysed an anticipated invasive BCI system lifecycle to identify the individual, organisational, and societal risks associated with BCIs, and controls that could be used to mitigate or eliminate these risks. A BCI system lifecycle work domain analysis model was developed and validated with 10 subject matter experts. The model was subsequently used to undertake a systems thinking-based risk assessment approach to identify risks that could emerge when functions are either undertaken sub-optimally or not undertaken at all. Eighteen broad risk themes were identified that could negatively impact the BCI system lifecycle in a variety of unique ways, while a larger number of controls for these risks were also identified. The most concerning risks included inadequate regulation of BCI technologies and inadequate training of BCI stakeholders, such as users and clinicians. In addition to specifying a practical set of risk controls to inform BCI device design, manufacture, adoption, and utilisation, the results demonstrate the complexity involved in managing BCI risks and suggests that a system-wide coordinated response is required. Future research is required to evaluate the comprehensiveness of the identified risks and the practicality of implementing the risk controls.


Assuntos
Interfaces Cérebro-Computador , Humanos , Estudos Prospectivos , Medição de Risco , Eletroencefalografia/métodos
8.
Sensors (Basel) ; 23(9)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37177761

RESUMO

Wearable electroencephalography (EEG) has the potential to improve everyday life through brain-computer interfaces (BCI) for applications such as sleep improvement, adaptive hearing aids, or thought-based digital device control. To make these innovations more practical for everyday use, researchers are looking to miniaturized, concealed EEG systems that can still collect neural activity precisely. For example, researchers are using flexible EEG electrode arrays that can be attached around the ear (cEEGrids) to study neural activations in everyday life situations. However, the use of such concealed EEG approaches is limited by measurement challenges such as reduced signal amplitudes and high recording system costs. In this article, we compare the performance of a lower-cost open-source amplification system, the OpenBCI Cyton+Daisy boards, with a benchmark amplifier, the MBrainTrain Smarting Mobi. Our results show that the OpenBCI system is a viable alternative for concealed EEG research, with highly similar noise performance, but slightly lower timing precision. This system can be a great option for researchers with a smaller budget and can, therefore, contribute significantly to advancing concealed EEG research.


Assuntos
Interfaces Cérebro-Computador , Auxiliares de Audição , Eletroencefalografia/métodos , Eletrodos , Ruído
9.
Sensors (Basel) ; 23(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36850850

RESUMO

A Brain-Computer Music Interface (BCMI) system may be designed to harness electroencephalography (EEG) signals for control over musical outputs in the context of emotionally expressive performance. To develop a real-time BCMI system, accurate and computationally efficient emotional biomarkers should first be identified. In the current study, we evaluated the ability of various features to discriminate between emotions expressed during music performance with the aim of developing a BCMI system. EEG data was recorded while subjects performed simple piano music with contrasting emotional cues and rated their success in communicating the intended emotion. Power spectra and connectivity features (Magnitude Square Coherence (MSC) and Granger Causality (GC)) were extracted from the signals. Two different approaches of feature selection were used to assess the contribution of neutral baselines in detection accuracies; 1- utilizing the baselines to normalize the features, 2- not taking them into account (non-normalized features). Finally, the Support Vector Machine (SVM) has been used to evaluate and compare the capability of various features for emotion detection. Best detection accuracies were obtained from the non-normalized MSC-based features equal to 85.57 ± 2.34, 84.93 ± 1.67, and 87.16 ± 0.55 for arousal, valence, and emotional conditions respectively, while the power-based features had the lowest accuracies. Both connectivity features show acceptable accuracy while requiring short processing time and thus are potential candidates for the development of a real-time BCMI system.


Assuntos
Interfaces Cérebro-Computador , Música , Humanos , Emoções Manifestas , Emoções , Nível de Alerta
10.
JAMA Neurol ; 80(3): 270-278, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36622685

RESUMO

Importance: Brain-computer interface (BCI) implants have previously required craniotomy to deliver penetrating or surface electrodes to the brain. Whether a minimally invasive endovascular technique to deliver recording electrodes through the jugular vein to superior sagittal sinus is safe and feasible is unknown. Objective: To assess the safety of an endovascular BCI and feasibility of using the system to control a computer by thought. Design, Setting, and Participants: The Stentrode With Thought-Controlled Digital Switch (SWITCH) study, a single-center, prospective, first in-human study, evaluated 5 patients with severe bilateral upper-limb paralysis, with a follow-up of 12 months. From a referred sample, 4 patients with amyotrophic lateral sclerosis and 1 with primary lateral sclerosis met inclusion criteria and were enrolled in the study. Surgical procedures and follow-up visits were performed at the Royal Melbourne Hospital, Parkville, Australia. Training sessions were performed at patients' homes and at a university clinic. The study start date was May 27, 2019, and final follow-up was completed January 9, 2022. Interventions: Recording devices were delivered via catheter and connected to subcutaneous electronic units. Devices communicated wirelessly to an external device for personal computer control. Main Outcomes and Measures: The primary safety end point was device-related serious adverse events resulting in death or permanent increased disability. Secondary end points were blood vessel occlusion and device migration. Exploratory end points were signal fidelity and stability over 12 months, number of distinct commands created by neuronal activity, and use of system for digital device control. Results: Of 4 patients included in analyses, all were male, and the mean (SD) age was 61 (17) years. Patients with preserved motor cortex activity and suitable venous anatomy were implanted. Each completed 12-month follow-up with no serious adverse events and no vessel occlusion or device migration. Mean (SD) signal bandwidth was 233 (16) Hz and was stable throughout study in all 4 patients (SD range across all sessions, 7-32 Hz). At least 5 attempted movement types were decoded offline, and each patient successfully controlled a computer with the BCI. Conclusions and Relevance: Endovascular access to the sensorimotor cortex is an alternative to placing BCI electrodes in or on the dura by open-brain surgery. These final safety and feasibility data from the first in-human SWITCH study indicate that it is possible to record neural signals from a blood vessel. The favorable safety profile could promote wider and more rapid translation of BCI to people with paralysis. Trial Registration: ClinicalTrials.gov Identifier: NCT03834857.


Assuntos
Interfaces Cérebro-Computador , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Encéfalo , Córtex Cerebral , Paralisia/etiologia , Estudos Prospectivos
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 208-213, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086083

RESUMO

This study details the development of a novel, approx. £20 electroencephalogram (EEG)-based brain-computer interface (BCI) intended to offer a financially and operationally accessible device that can be deployed on a mass scale to facilitate education and public engagement in the domain of EEG sensing and neurotechnologies. Real-time decoding of steady-state visual evoked potentials (SSVEPs) is achieved using variations of the widely-used canonical correlation analysis (CCA) algorithm: multi-set CCA and generalised CCA. All BCI functionality is executed on board an inexpensive ESP32 microcontroller. SSVEP decoding accuracy of 95.56 ± 3.74% with an ITR of 102 bits/min was achieved with modest calibration.


Assuntos
Interfaces Cérebro-Computador , Potenciais Evocados Visuais , Algoritmos , Calibragem , Eletroencefalografia
12.
Biomed Res Int ; 2022: 4100381, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36060141

RESUMO

Steady-state somatosensory-evoked potential- (SSSEP-) based brain-computer interfaces (BCIs) have been applied for assisting people with physical disabilities since it does not require gaze fixation or long-time training. Despite the advancement of various noninvasive electroencephalogram- (EEG-) based BCI paradigms, researches on SSSEP with the various frequency range and related classification algorithms are relatively unsettled. In this study, we investigated the feasibility of classifying the SSSEP within high-frequency vibration stimuli induced by a versatile coin-type eccentric rotating mass (ERM) motor. Seven healthy subjects performed selective attention (SA) tasks with vibration stimuli attached to the left and right index fingers. Three EEG feature extraction methods, followed by a support vector machine (SVM) classifier, have been tested: common spatial pattern (CSP), filter-bank CSP (FBCSP), and mutual information-based best individual feature (MIBIF) selection after the FBCSP. Consequently, the FBCSP showed the highest performance at 71.5 ± 2.5% for classifying the left and right-hand SA tasks than the other two methods (i.e., CSP and FBCSP-MIBIF). Based on our findings and approach, the high-frequency vibration stimuli using low-cost coin motors with the FBCSP-based feature selection can be potentially applied to developing practical SSSEP-based BCI systems.


Assuntos
Interfaces Cérebro-Computador , Algoritmos , Eletroencefalografia/métodos , Humanos , Máquina de Vetores de Suporte
13.
J Neural Eng ; 19(4)2022 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-35947962

RESUMO

Objective.Understanding neural encoding and decoding processes are crucial to the development of brain-machine interfaces (BMI). Higher decoding speed of neural signals is required for the large-scale neural data and the extremely low detection delay of closed-loop feedback experiment.Approach.To achieve higher neural decoding speed, we proposed a novel adaptive higher-order nonlinear point-process filter based on the variational Bayesian inference (VBI) framework, called the HON-VBI. This algorithm avoids the complex Monte Carlo random sampling in the traditional method. Using the VBI method, it can quickly implement inferences of state posterior distribution and the tuning parameters.Main results.Our result demonstrates the effectiveness and advantages of the HON-VBI by application for decoding the multichannel neural spike trains of the simulation data and real data. Compared with traditional methods, the HON-VBI greatly reduces the decoding time of large-scale neural spike trains. Through capturing the nonlinear evolution of system state and accurate estimating of time-varying tuning parameters, the decoding accuracy is improved.Significance.Our work can be applied to rapidly decode large-scale multichannel neural spike trains in BMIs.


Assuntos
Interfaces Cérebro-Computador , Potenciais de Ação , Algoritmos , Teorema de Bayes , Modelos Neurológicos , Método de Monte Carlo
14.
Int J Neural Syst ; 32(10): 2250041, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35881017

RESUMO

The assessment of physiological signals such as the electroencephalography (EEG) has become a key point in the research area of emotion detection. This study compares the performance of two EEG devices, a low-cost brain-computer interface (BCI) (Emotiv EPOC+) and a high-end EEG (BrainVision), for the detection of four emotional conditions over 20 participants. For that purpose, signals were acquired with both devices under the same experimental procedure, and a comparison was made under three different scenarios, according to the number of channels selected and the sampling frequency of the signals analyzed. A total of 16 statistical, spectral and entropy features were extracted from the EEG recordings. A statistical analysis revealed a major number of statistically significant features for the high-end EEG than the BCI device under the three comparative scenarios. In addition, different machine learning algorithms were used for evaluating the classification performance of the features extracted from high-end EEG and low-cost BCI in each scenario. Artificial neural networks reported the best performance for both devices with an F[Formula: see text]-score of 75.08% for BCI and 98.78% for EEG. Although the professional EEG outcomes were higher than the low-cost BCI ones, both devices demonstrated a notable performance for the classification of the four emotional conditions.


Assuntos
Interfaces Cérebro-Computador , Algoritmos , Eletroencefalografia/métodos , Emoções/fisiologia , Humanos , Redes Neurais de Computação
15.
Theranostics ; 12(7): 3273-3287, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35547770

RESUMO

Background: Visually evoked potential (VEP) is widely used to detect optic neuropathy in basic research and clinical practice. Traditionally, VEP is recorded non-invasively from the surface of the skull over the visual cortex. However, its trace amplitude is highly variable, largely due to intracranial modulation and artifacts. Therefore, a safe test with a strong and stable signal is highly desirable to assess optic nerve function, particularly in neurosurgical settings and animal experiments. Methods: Minimally invasive trans-sphenoidal endoscopic recording of optic chiasmatic potential (OCP) was carried out with a titanium screw implanted onto the sphenoid bone beneath the optic chiasm in the goat, whose sphenoidal anatomy is more human-like than non-human primates. Results: The implantation procedure was swift (within 30 min) and did not cause any detectable abnormality in fetching/moving behaviors, skull CT scans and ophthalmic tests after surgery. Compared with traditional VEP, the amplitude of OCP was 5-10 times stronger, more sensitive to weak light stimulus and its subtle changes, and was more repeatable, even under extremely low general anesthesia. Moreover, the OCP signal relied on ipsilateral light stimulation, and was abolished immediately after complete optic nerve (ON) transection. Through proof-of-concept experiments, we demonstrated several potential applications of the OCP device: (1) real-time detector of ON function, (2) detector of region-biased retinal sensitivity, and (3) therapeutic electrical stimulator for the optic nerve with low and thus safe excitation threshold. Conclusions: OCP developed in this study will be valuable for both vision research and clinical practice. This study also provides a safe endoscopic approach to implant skull base brain-machine interface, and a feasible in vivo testbed (goat) for evaluating safety and efficacy of skull base brain-machine interface.


Assuntos
Técnicas Biossensoriais , Interfaces Cérebro-Computador , Animais , Quiasma Óptico , Base do Crânio/anatomia & histologia , Base do Crânio/cirurgia , Vias Visuais
16.
Artigo em Inglês | MEDLINE | ID: mdl-35584066

RESUMO

Behavioral assessment of sound localization in the Coma Recovery Scale-Revised (CRS-R) poses a significant challenge due to motor disability in patients with disorders of consciousness (DOC). Brain-computer interfaces (BCIs), which can directly detect brain activities related to external stimuli, may thus provide an approach to assess DOC patients without the need for any physical behavior. In this study, a novel audiovisual BCI system was developed to simulate sound localization evaluation in CRS-R. Specifically, there were two alternatively flashed buttons on the left and right sides of the graphical user interface, one of which was randomly chosen as the target. The auditory stimuli of bell sounds were simultaneously presented by the ipsilateral loudspeaker during the flashing of the target button, which prompted patients to selectively attend to the target button. The recorded electroencephalography data were analyzed in real time to detect event-related potentials evoked by the target and further to determine whether the target was attended to or not. A significant BCI accuracy for a patient implied that he/she had sound localization. Among eighteen patients, eleven and four showed sound localization in the BCI and CRS-R, respectively. Furthermore, all patients showing sound localization in the CRS-R were among those detected by our BCI. The other seven patients who had no sound localization behavior in CRS-R were identified by the BCI assessment, and three of them showed improvements in the second CRS-R assessment after the BCI experiment. Thus, the proposed BCI system is promising for assisting the assessment of sound localization and improving the clinical diagnosis of DOC patients.


Assuntos
Interfaces Cérebro-Computador , Pessoas com Deficiência , Transtornos Motores , Localização de Som , Coma/diagnóstico , Estado de Consciência , Transtornos da Consciência/diagnóstico , Eletroencefalografia , Feminino , Humanos
17.
J Neural Eng ; 19(2)2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35475424

RESUMO

Objective. The aim of this review was to systematically identify the ethical implications of visual neuroprostheses.Approach. A systematic search was performed in both PubMed and Embase using a search string that combined synonyms for visual neuroprostheses, brain-computer interfaces (BCIs), cochlear implants (CIs), and ethics. We chose to include literature on BCIs and CIs, because of their ethically relavant similarities and functional parallels with visual neuroprostheses.Main results. We included 84 articles in total. Six focused specifically on visual prostheses. The other articles focused more broadly on neurotechnologies, on BCIs or CIs. We identified 169 ethical implications that have been categorized under seven main themes: (a) benefits for health and well-being; (b) harm and risk; (c) autonomy; (d) societal effects; (e) clinical research; (f) regulation and governance; and (g) involvement of experts, patients and the public.Significance. The development and clinical use of visual neuroprostheses is accompanied by ethical issues that should be considered early in the technological development process. Though there is ample literature on the ethical implications of other types of neuroprostheses, such as motor neuroprostheses and CIs, there is a significant gap in the literature regarding the ethical implications of visual neuroprostheses. Our findings can serve as a starting point for further research and normative analysis.


Assuntos
Interfaces Cérebro-Computador , Próteses Neurais , Humanos
18.
Sensors (Basel) ; 21(22)2021 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-34833681

RESUMO

The emergence of innovative neurotechnologies in global brain projects has accelerated research and clinical applications of BCIs beyond sensory and motor functions. Both invasive and noninvasive sensors are developed to interface with cognitive functions engaged in thinking, communication, or remembering. The detection of eye movements by a camera offers a particularly attractive external sensor for computer interfaces to monitor, assess, and control these higher brain functions without acquiring signals from the brain. Features of gaze position and pupil dilation can be effectively used to track our attention in healthy mental processes, to enable interaction in disorders of consciousness, or to even predict memory performance in various brain diseases. In this perspective article, we propose the term 'CyberEye' to encompass emerging cognitive applications of eye-tracking interfaces for neuroscience research, clinical practice, and the biomedical industry. As CyberEye technologies continue to develop, we expect BCIs to become less dependent on brain activities, to be less invasive, and to thus be more applicable.


Assuntos
Interfaces Cérebro-Computador , Tecnologia de Rastreamento Ocular , Encéfalo , Cognição , Movimentos Oculares
19.
Sensors (Basel) ; 21(21)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34770553

RESUMO

Motor Imagery (MI)-based Brain-Computer Interfaces (BCIs) have been widely used as an alternative communication channel to patients with severe motor disabilities, achieving high classification accuracy through machine learning techniques. Recently, deep learning techniques have spotlighted the state-of-the-art of MI-based BCIs. These techniques still lack strategies to quantify predictive uncertainty and may produce overconfident predictions. In this work, methods to enhance the performance of existing MI-based BCIs are proposed in order to obtain a more reliable system for real application scenarios. First, the Monte Carlo dropout (MCD) method is proposed on MI deep neural models to improve classification and provide uncertainty estimation. This approach was implemented using Shallow Convolutional Neural Network (SCNN-MCD) and with an ensemble model (E-SCNN-MCD). As another contribution, to discriminate MI task predictions of high uncertainty, a threshold approach is introduced and tested for both SCNN-MCD and E-SCNN-MCD approaches. The BCI Competition IV Databases 2a and 2b were used to evaluate the proposed methods for both subject-specific and non-subject-specific strategies, obtaining encouraging results for MI recognition.


Assuntos
Interfaces Cérebro-Computador , Imaginação , Algoritmos , Eletroencefalografia , Humanos , Incerteza
20.
J Neural Eng ; 18(6)2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34678801

RESUMO

Objective.Present methods for assessing color vision require the person's active participation. Here we describe a brain-computer interface-based method for assessing color vision that does not require the person's participation.Approach.This method uses steady-state visual evoked potentials to identify metamers-two light sources that have different spectral distributions but appear to the person to be the same color.Main results.We demonstrate that: minimization of the visual evoked potential elicited by two flickering light sources identifies the metamer; this approach can distinguish people with color-vision deficits from those with normal color vision; and this metamer-identification process can be automated.Significance.This new method has numerous potential clinical, scientific, and industrial applications.


Assuntos
Interfaces Cérebro-Computador , Visão de Cores , Potenciais Evocados Visuais , Eletroencefalografia/métodos , Humanos , Luz , Estimulação Luminosa/métodos , Projetos de Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA