Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(19): 4409-4415, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38864917

RESUMO

We present a novel approach for iodide sensing based on the heavy-atom effect to quench the green fluorescent emission of organosilicon nanoparticles (OSiNPs). The fluorescence of OSiNPs was significantly quenched (up to 97.4% quenching efficiency) in the presence of iodide ions (I-) through oxidation by hydrogen peroxide. Therefore, OSiNPs can serve as a fluorescent probe to detect I- with high selectivity and sensitivity. The highly selective response is attributed to the hydrophilic surface enabling good dispersion in aqueous solutions and the lipophilic core allowing the generated liposoluble I2 to approach and quench the fluorescence of OSiNPs. The linear working range for I- was from 0 to 50 µM, with a detection limit of 0.1 µM. We successfully applied this nanosensor to determine iodine content in edible salt. Furthermore, the fluorescent OSiNPs can be utilized for the determination of total antioxidant capacity (TAC). Antioxidants reduce I2 to I-, and the extent of quenching by the remaining I2 on the OSiNPs indicates the TAC level. The responses to ascorbic acid, pyrogallic acid, and glutathione were investigated, and the detection limit for ascorbic acid was as low as 0.03 µM. It was applied to the determination of TAC in ascorbic acid tablets and fruit juices, indicating the potential application of the OSiNP-based I2 sensing technique in the field of food analysis.


Assuntos
Antioxidantes , Corantes Fluorescentes , Iodetos , Limite de Detecção , Nanopartículas , Iodetos/análise , Iodetos/química , Nanopartículas/química , Antioxidantes/análise , Antioxidantes/química , Corantes Fluorescentes/química , Compostos de Organossilício/química , Espectrometria de Fluorescência/métodos , Ácido Ascórbico/análise , Sucos de Frutas e Vegetais/análise
2.
J Antibiot (Tokyo) ; 72(6): 449-460, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30886347

RESUMO

Steryl glycosides are prevalent in nature and have unique biological activities dictated by sterol structure, sugar composition, and the stereochemical attachment of the aglycone. A single configurational switch can have profound biological consequences meriting the systematic study of structure and function relationships. Steryl congeners of N-acetyl neuraminic acid (NANA) impact neurobiological processes and may also mediate host/microbe interactions. In order to study these processes, a platform for the synthesis of ß-steryl sialosides has been established. Promoter-free glycosidations using a novel α-linked sialyl iodide donor efficiently provide unique amphiphilic sialoglycoconjugates for examining bioactivities in various systems.


Assuntos
Iodetos/síntese química , Ácidos Siálicos/química , Glicosídeos/química , Iodetos/química , Estrutura Molecular , Esteróis/química
3.
Health Phys ; 117(4): 362-377, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30913060

RESUMO

Experiments were performed with 30 11 cm × 42.5 cm × 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of Am, Cs, Co, and Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as nonuniformity of the photomultiplier tube, photocathode response, and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.


Assuntos
Simulação por Computador , Iodetos/química , Método de Monte Carlo , Contagem de Cintilação/instrumentação , Sódio/química , Tálio/química , Desenho de Equipamento , Raios gama , Humanos , Contagem de Cintilação/métodos
4.
Radiat Prot Dosimetry ; 185(3): 402-408, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30806469

RESUMO

One of the authors (O.K.) stayed in the area located ~110 km south from the Fukushima Daiichi Nuclear Power Plant during the arrival of radioactive plumes released into the environment due to the accident in March 2011 in Japan. A previous study determined his 131I thyroid content using an NaI(Tl) spectrometer. The one remaining issue was to investigate the measurement error due to inevitable differences in the configuration (e.g. the thyroid shape and volume) between the physical phantom employed for calibration of the spectrometer and the real subject. In the present study, Monte Carlo simulations for the thyroid measurements were performed using the Monte Carlo N-Particle (MNCP) code to investigate discrepancies in peak efficiencies of the spectrometer between the personalised voxel phantom created from O.K.'s magnetic resonance images and the several typical/reference phantoms that exist. As a result, the peak efficiencies for the Oak Ridge Institute of Nuclear Studies (ORINS) phantom were found to be comparable to those for the reference voxel phantoms reproducing realistic human anatomy (the Adult Male phantom and the Japanese Male phantom). The peak efficiency for the personalised phantom, on the other hand, was fairly close to that of the other physical phantom (the Transfer phantom) actually used for the calibration of the spectrometer, suggesting that the 131I thyroid content determined for him in the previous study was sufficiently accurate. The discrepancies of peak efficiencies at the primal photon energy of 131I (365 keV) among the different phantoms were improved by extending the distance between the neck and the spectrometer; however, the appropriate measurement geometry in an actual situation will depend on the primary purpose of the measurements and should be determined accordingly.


Assuntos
Simulação por Computador , Iodetos/química , Radioisótopos do Iodo/análise , Método de Monte Carlo , Imagens de Fantasmas , Monitoramento de Radiação/instrumentação , Sódio/química , Tálio/química , Glândula Tireoide/metabolismo , Humanos , Centrais Nucleares , Monitoramento de Radiação/métodos
5.
Australas Phys Eng Sci Med ; 41(1): 31-39, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29230656

RESUMO

GATE is currently considered in scintigraphic imaging as a powerful tool to develop, design and optimize nuclear medicine modalities. This paper describes the GATE simulation of a pixelated gamma camera which is dedicated to high resolution of small animals imaging. It consists of a CsI(Na) crystal array coupled to position sensitive photomultiplier tube. The simulation model includes photon tracking through low energy high resolution hexagonal parallel holes collimator, CsI(Na) pixelated crystal, back-compartment, and camera shielding. Simulations were compared with experimental results by some criteria such as energy spectrum, energy resolution, spatial resolution, sensitivity and count profiles obtained from line and point sources imaging. The acquired energy resolution show good agreement with measured spectra. Difference between calculated and experimental values is about 0.3% for absolute sensitivity measurement. The result of the image uniformity is more consistent after implementation of non-uniformity correction. These values were about 1.3 and 1.2% for experimental and simulation study in the central field of view, respectively. Measurements showed that the spatial resolutions differences at the head surface along the long dimensions of gamma camera for simulation and experimental differed by no more than 4%.Differences along the short axis were about 6%. The FWHMs of images of point and line sources show good consistency between experimental images and corresponding simulated ones. The difference between experimental and simulated system parameters was within 11%. Our results demonstrate the ability and flexibility of the Monte Carlo simulation for modeling pixelated gamma camera with position sensitive detector by selecting the appropriate parameters for digitizer chain and collimator position on the detector surface.


Assuntos
Césio/química , Simulação por Computador , Câmaras gama , Iodetos/química , Método de Monte Carlo , Software , Tomografia Computadorizada de Emissão de Fóton Único , Animais , Cristalização , Imagens de Fantasmas , Fótons
6.
Eur J Med Chem ; 77: 388-99, 2014 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-24681027

RESUMO

The new mixed ligand silver(I) complex of formula [AgI(TPP)2(MBZT)] (1) was obtained by reacting 2-mercapto-benzothiazole (MBZT) with triphenylphosphine (TPP). The complex was characterized by m.p., vibrational spectroscopy (FT-IR), (1)H NMR, UV-vis, ESI-MS spectroscopic techniques and its structure was confirmed by X-ray crystallography. Mixed ligand complexes of silver(I) iodide with thiones and phosphines are very rare in the literature and to the best of our knowledge compound 1 is the first of this kind exhibiting significant biological effects. Complex 1 was evaluated for its in vitro cytotoxic activity (cell viability) under irradiation with UV light and without irradiation against human cancer cell lines: MCF-7 (breast, ER positive), MDA-MB-231 (breast, ER negative), Caki-1 (renal), A549 (lung), OAW-42 (ovarian), HeLa (cervical) and additionally against the normal human lung cell line MRC-5 (normal human fetal lung fibroblast cells) and normal immortalized human mammary gland epithelial cell line (MTSV17) with SRB assay. The results showed that 1 mediates a strong cytotoxic response to the tested normal and cancer cell lines. It exhibits equal activity against MDA-MB-231 cells where estrogen receptors (ERs) are devoid with the one against MCF-7 where ERs are present. Molecular docking studies have shown that 1 is docked in the different pocket than that of the ERs modulators. The binding affinity of 1 towards the intracellular molecules DNA and lipoxygenase (LOX) was studied for the evaluation of the mechanism of its cytostasis. The binding constant (Kb) of 1 towards CT-DNA was calculated by UV-Vis and fluorescent spectra suggesting intercalation or electrostatic interactions of 1 into DNA. Docking studies on DNA-complex interactions confirm the binding of 1. Moreover, the influence of complex 1 on the catalytic peroxidation of linoleic acid to hydroperoxylinoleic acid by the enzyme lipoxygenase (LOX) was kinetically and theoretically studied. In addition, since the deactivation of cisplatin caused by glutathione, seems to be an important determinant of its cytotoxic effects, the reaction of 1 with glutathione (GSH) was investigated by UV-absorption spectroscopy.


Assuntos
Antineoplásicos/farmacologia , DNA/química , Glutationa/química , Iodetos/química , Lipoxigenase/química , Compostos Organometálicos/química , Compostos Organometálicos/farmacologia , Compostos de Prata/química , Antineoplásicos/síntese química , Antineoplásicos/química , Apoptose/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Cristalografia por Raios X , DNA/metabolismo , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Glutationa/metabolismo , Células HeLa , Humanos , Ácido Linoleico/química , Ácido Linoleico/metabolismo , Lipoxigenase/metabolismo , Células MCF-7 , Simulação de Acoplamento Molecular , Estrutura Molecular , Compostos Organometálicos/síntese química , Relação Estrutura-Atividade , Raios Ultravioleta
7.
J Org Chem ; 79(4): 1736-48, 2014 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-24490844

RESUMO

Carbohydrates mediate a wide range of biological processes, and understanding these events and how they might be influenced is a complex undertaking that requires access to pure glycoconjugates. The isolation of sufficient quantities of carbohydrates and glycolipids from biological samples remains a significant challenge that has redirected efforts toward chemical synthesis. However, progress toward complex glycoconjugate total synthesis has been slowed by the need for multiple protection and deprotection steps owing to the large number of similarly reactive hydroxyls in carbohydrates. Two methodologies, regioselective silyl exchange technology (ReSET) and glycosyl iodide glycosylation have now been integrated to streamline the synthesis of the globo series trisaccharides (globotriaose and isoglobotriaose) and α-lactosylceramide (α-LacCer). These glycoconjugates include tumor-associated carbohydrate antigens (TACAs) and immunostimulatory glycolipids that hold promise as immunotherapeutics. Beyond the utility of the step-economy syntheses afforded by this synthetic platform, the studies also reveal a unique electronic interplay between acetate and silyl ether protecting groups. Incorporation of acetates proximal to silyl ethers attenuates their reactivity while reducing undesirable side reactions. This phenomenon can be used to fine-tune the reactivity of silylated/acetylated sugar building blocks.


Assuntos
Antígenos Glicosídicos Associados a Tumores/química , Antígenos Glicosídicos Associados a Tumores/metabolismo , Carboidratos/química , Carboidratos/síntese química , Éteres/química , Glicoconjugados/química , Glicoconjugados/síntese química , Glicolipídeos/síntese química , Iodetos/química , Silanos/química , Trissacarídeos/química , Glicolipídeos/química , Glicosilação
9.
Radiat Prot Dosimetry ; 155(3): 292-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23390143

RESUMO

This study presents the simulation results for 10.16 cm diameter and 7.62 cm thickness NaI(Tl) detector response, which is housed in a partially shielded scanning bed whole-body monitor (WBM), due to activity distributed in the axial cavities provided in the Indian reference BOMAB phantom. Experimental detection efficiency (DE) for axial cavity activity distribution (ACAD) in this phantom for photon emissions of (133)Ba, (137)Cs and (60)Co is used to validate DEs estimated using Monte Carlo code FLUKA. Simulations are also carried out to estimate DEs due to uniform activity distribution (UAD) as in the standard BOMAB phantom. The results show that the DE is ∼3.8 % higher for UAD when compared with ACAD in the case of (40)K (1460 keV) and this relative difference increases to ∼7.0 % for (133)Ba (∼356 keV) photons. The corresponding correction factors for calibration with Indian phantom are provided. DEs are also simulated for activity distributed as a planar disc at the centre of the axial cavity in each part of the BOMAB phantom (PDAD) and the deviations of these DEs are within 1 % of the ACAD results. Thus, PDAD can also be used for ACAD in scanning geometry. An analytical solution for transmitted mono-energetic photons from a two-dimensional slab is provided for qualitative explanation of difference in DEs due to variation in activity distributions in the phantom. The effect on DEs due to different phantom part dimensions is also studied and lower DEs are observed for larger parts.


Assuntos
Iodetos/química , Método de Monte Carlo , Imagens de Fantasmas , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Sódio/química , Tálio/química , Imagem Corporal Total/instrumentação , Contagem Corporal Total/instrumentação , Calibragem , Simulação por Computador , Humanos , Fótons
10.
J Chem Phys ; 137(12): 124107, 2012 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-23020324

RESUMO

The formation of water clusters on Li(+), Na(+), K(+), Cl(-), and I(-) ions from water vapor at atmospheric conditions have been studied using Monte Carlo simulations. The extended simple point charge model has been employed for water molecules. The polarization of ions in the field of molecules and the polarization of molecules in the field of ions have been considered explicitly in the total Hamiltonian of the molecular system. The cluster formation work and the Gibbs free energy and enthalpy of attachment reactions of one water molecule to the cluster have been calculated via the bicanonical ensemble method. Our results reveal the formation of stable clusters in equilibrium with the moist atmosphere in a wide range of vapor pressure values, with largest clusters are formed around cations. Decreasing the temperature, from 293 K to 253 K, leads to the formation of larger equilibrium clusters, and enhances the stability of systems as whole. According to clusters' molecular structures, negative ions are expected to be more active in atmospheric processes, including chemical reactions and cloud formation, than positive ones.


Assuntos
Atmosfera/química , Cloretos/química , Iodetos/química , Metais Alcalinos/química , Água/química , Íons/química , Método de Monte Carlo , Termodinâmica
11.
Australas Phys Eng Sci Med ; 34(3): 351-60, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21710232

RESUMO

We present a quantitative study on the performance of cadmium zinc telluride (CZT), thallium-doped sodium iodide (NaI(Tl)) and germanium (Ge) detectors as potential Compton camera absorbers. The GEANT4 toolkit was used to model the performance of these materials over the nuclear medicine energy range. CZT and Ge demonstrate the highest and lowest efficiencies respectively. Although the best spatial resolution was attained for Ge, its lowest ratio of single photoelectric to multiple interactions suggests that it is most prone to inter-pixel cross-talk. In contrast, CZT, which demonstrates the least positioning error due to multiple interactions, has a comparable spatial resolution with Ge. Therefore, we modelled a Compton camera system based on silicon (Si) and CZT as the scatterer and absorber respectively. The effects of the detector parameters of our proposed system on image resolution were evaluated and our results show good agreement with previous studies. Interestingly, spatial resolution which accounted for the least image degradation at 140.5 keV became the dominant degrading factor at 511 keV, indicating that the absorber parameters play some key roles at higher energies. The results of this study have validated the predictions by An et al. which state that the use of a higher energy gamma source together with reduction of the absorber segmentation to sub-millimetre could achieve the image resolution of 5 mm required in medical imaging.


Assuntos
Cádmio/química , Simulação por Computador , Iodetos/química , Método de Monte Carlo , Radiometria/instrumentação , Sódio/química , Telúrio/química , Tálio/química , Zinco/química , Desenho de Equipamento , Câmaras gama , Raios gama , Germânio/química , Radiometria/métodos , Cintilografia/instrumentação , Silício/química , Software
12.
J Chem Phys ; 134(1): 014505, 2011 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-21219005

RESUMO

The structure of molten AgCl, AgI, and their eutectic mixture Ag(Cl(0.43)I(0.57)) is studied by means of molecular dynamics simulations of polarizable ion model potentials. The corresponding static coherent structure factors reproduce quite well the available neutron scattering data. The qualitative behavior of the simulated partial structure factors and radial distribution functions for molten AgCl and AgI is that predicted by the reverse Monte Carlo modeling of the experimental data. The AgI results are also in qualitative agreement with those calculated from ab initio molecular dynamics.


Assuntos
Iodetos/química , Simulação de Dinâmica Molecular , Compostos de Prata/química , Íons/química , Estrutura Molecular , Método de Monte Carlo , Teoria Quântica
13.
Med Phys ; 35(7): 3180-93, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18697543

RESUMO

The practice of diagnostic x-ray imaging has been transformed with the emergence of digital detector technology. Although digital systems offer many practical advantages over conventional film-based systems, their spatial resolution performance can be a limitation. The authors present a Monte Carlo study to determine fundamental resolution limits caused by x-ray interactions in four converter materials: Amorphous silicon (a-Si), amorphous selenium, cesium iodide, and lead iodide. The "x-ray interaction" modulation transfer function (MTF) was determined for each material and compared in terms of the 50% MTF spatial frequency and Wagner's effective aperture for incident photon energies between 10 and 150 keV and various converter thicknesses. Several conclusions can be drawn from their Monte Carlo study. (i) In low-Z (a-Si) converters, reabsorption of Compton scatter x rays limits spatial resolution with a sharp MTF drop at very low spatial frequencies (< 0.3 cycles/mm), especially above 60 keV; while in high-Z materials, reabsorption of characteristic x rays plays a dominant role, resulting in a mid-frequency (1-5 cycles/mm) MTF drop. (ii) Coherent scatter plays a minor role in the x-ray interaction MTF. (iii) The spread of energy due to secondary electron (e.g., photoelectrons) transport is significant only at very high spatial frequencies. (iv) Unlike the spread of optical light in phosphors, the spread of absorbed energy from x-ray interactions does not significantly degrade spatial resolution as converter thickness is increased. (v) The effective aperture results reported here represent fundamental spatial resolution limits of the materials tested and serve as target benchmarks for the design and development of future digital x-ray detectors.


Assuntos
Diagnóstico por Imagem/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Raios X , Algoritmos , Césio/química , Diagnóstico por Imagem/métodos , Desenho de Equipamento , Humanos , Iodetos/química , Chumbo/química , Luz , Método de Monte Carlo , Fósforo/química , Fótons , Espalhamento de Radiação , Selênio/química , Silício/química
14.
Med Phys ; 35(7): 3194-204, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18697544

RESUMO

A frequency-dependent x-ray Swank factor based on the "x-ray interaction" modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI2) for incident photon energies between 10 and 150 keV and various converter thicknesses. When scaled by the quantum efficiency, the x-ray Swank factor describes the best possible detective quantum efficiency (DQE) a detector can have. As such, this x-ray interaction DQE provides a target performance benchmark. It is expressed as a function of (Fourier-based) spatial frequency and takes into consideration signal and noise correlations introduced by reabsorption of Compton scatter and photoelectric characteristic emissions. It is shown that the x-ray Swank factor is largely insensitive to converter thickness for quantum efficiency values greater than 0.5. Thus, while most of the tabulated values correspond to thick converters with a quantum efficiency of 0.99, they are appropriate to use for many detectors in current use. A simple expression for the x-ray interaction DQE of digital detectors (including noise aliasing) is derived in terms of the quantum efficiency, x-ray Swank factor, detector element size, and fill factor. Good agreement is shown with DQE curves published by other investigators for each converter material, and the conditions required to achieve this ideal performance are discussed. For high-resolution imaging applications, the x-ray Swank factor indicates: (i) a-Si should only be used at low-energy (e.g., mammography); (ii) a-Se has the most promise for any application below 100 keV; and (iii) while quantum efficiency may be increased at energies just above the K edge in CsI and PbI2, this benefit is offset by a substantial drop in the x-ray Swank factor, particularly at high spatial frequencies.


Assuntos
Diagnóstico por Imagem/instrumentação , Raios X , Césio/química , Diagnóstico por Imagem/métodos , Elétrons , Desenho de Equipamento , Análise de Fourier , Humanos , Iodetos/química , Chumbo/química , Método de Monte Carlo , Teoria Quântica , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Selênio/química , Silício/química
15.
Phys Med Biol ; 53(5): 1325-51, 2008 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-18296765

RESUMO

Active matrix, flat-panel x-ray imagers based on a-Si:H thin-film transistors offer many advantages and are widely utilized in medical imaging applications. Unfortunately, the detective quantum efficiency (DQE) of conventional flat-panel imagers incorporating scintillators or a-Se photoconductors is significantly limited by their relatively modest signal-to-noise ratio, particularly in applications involving low x-ray exposures or high spatial resolution. For this reason, polycrystalline HgI2 is of considerable interest by virtue of its low effective work function, high atomic number and the possibility of large-area deposition. In this study, a detailed investigation of the properties of prototype, flat-panel arrays coated with two forms of this high-gain photoconductor are reported. Encouragingly, high x-ray sensitivity, low dark current and spatial resolution close to the theoretical limits were observed from a number of prototypes. In addition, input-quantum-limited DQE performance was measured from one of the prototypes at relatively low exposures. However, high levels of charge trapping, lag and polarization, as well as pixel-to-pixel variations in x-ray sensitivity are of concern. While the results of the current study are promising, further development will be required to realize prototypes exhibiting the characteristics necessary to allow practical implementation of this approach.


Assuntos
Diagnóstico por Imagem/instrumentação , Iodetos/química , Mercúrio/química , Modelos Lineares , Método de Monte Carlo , Sensibilidade e Especificidade , Raios X
16.
J Phys Chem B ; 112(2): 621-35, 2008 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-18183958

RESUMO

The structural and thermodynamic properties of Na+(CH3CN)n, I-(CH3CN)n, and NaI(CH3CN)n clusters have been investigated by means of room-temperature Monte Carlo simulations with model potentials developed to reproduce the properties of small clusters predicted by quantum chemistry. Ions are found to adopt an interior solvation shell structure, with a first solvation shell containing approximately 6 and approximately 8 acetonitrile molecules for large Na+(CH3CN)n and I-(CH3CN)n clusters, respectively. Structural features of Na+(CH3CN)n are found to be similar to those of Na+(H2O)n clusters, but those of I-(CH3CN)n contrast with those of I-(H2O)n, for which "surface" solvation structures were observed. The potential of mean force calculations demonstrates that the NaI ion pair is thermodynamically stable with respect to ground-state ionic dissociation in acetonitrile clusters. The properties of NaI(CH3CN)n clusters exhibit some similarities with NaI(H2O)n clusters, with the existence of contact ion pair and solvent-separated ion pair structures, but, in contrast to water clusters, both types of ion pairs adopt a well-defined interior ionic solvation shell structure in acetonitrile clusters. Whereas contact ion pair species are thermodynamically favored in small clusters, solvent-separated ion pairs tend to become thermodynamically more stable above a cluster size of approximately 26. Hence, ground-state charge separation appears to occur at larger cluster sizes for acetonitrile clusters than for water clusters. We propose that the lack of a large Na+(CH3CN)n product signal in NaI(CH3CN)n multiphoton ionization experiments could arise from extensive stabilization of the ground ionic state by the solvent and possible inhibition of the photoexcitation mechanism, which may be less pronounced for NaI(H2O)n clusters because of surface solvation structures. Alternatively, increased solvent evaporation resulting from larger excess energies upon photoexcitation or major solvent reorganization on the ionized state could account for the observed solvent-selectivity in NaI cluster multiphoton ionization.


Assuntos
Acetonitrilas/química , Iodetos/química , Sódio/química , Elétrons , Íons/química , Modelos Moleculares , Conformação Molecular , Método de Monte Carlo , Solubilidade , Solventes , Termodinâmica
18.
Radiat Prot Dosimetry ; 114(1-3): 264-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15933119

RESUMO

A complete evaluation strategy had been developed for thoracic X-ray imaging. It has been validated by investigating five chest-radiography systems, two of these systems after optimising image processing. The systems were a screen-film combination, a selenium drum, a conventional and a transparent imaging plate and a Cs/I-based flat panel detector (the two latter ones have been optimised using different post processing). At first all detectors have been characterised using physical parameters like DQE and MTF. After that all systems have been evaluated by human observer studies using anatomy in clinical images (VGA, ICS) and added pathological structures in thoracic phantom images (ROC). The ranking of the image quality of the systems was nearly the same in all studies. There was a similar assessment of main image quality parameters like spatial resolution, dynamic range and MTF. The modification of image post processing changed the visibility of pathological structures more than the visualisation of the anatomical criteria. The assessment of the clinical image quality has to be done for anatomical structures, and the recognition of pathological structures has to be evaluated.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/instrumentação , Radiografia Torácica/métodos , Césio/química , Humanos , Iodetos/química , Variações Dependentes do Observador , Imagens de Fantasmas , Curva ROC , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Radiografia , Software , Filme para Raios X , Raios X
SELEÇÃO DE REFERÊNCIAS