Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Emerg Radiol ; 26(6): 647-654, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31444680

RESUMO

PURPOSE: In the literature, no consensus exists about which CT protocol is to be adopted in patients who underwent high-energy blunt trauma. The aim of the study is to evaluate the additional value of the arterial phase in the CT assessment of vascular injuries of the liver. METHODS: Admission CT examinations for patients with traumatic injury of the liver due to high-energy blunt trauma, performed between 2011 and 2017 in two major trauma centres, were retrospectively reviewed. Images were analysed for presence or absence of liver parenchymal injury, intrahepatic contained vascular injuries and active bleeding in the arterial and portal venous phase of the CT study. RESULTS: Two hundred twelve patients have been identified. Parenchymal injuries were detected as isolated in 90.6% of cases, whereas they were associated with vascular injuries in 9.4% of cases: contained vascular injuries in 3.3% and active bleeding in 6.1%. Out of all parenchymal injuries detected on the CT portal venous phase, 90.5% were also detectable in the arterial phases (p < 0.0001). All of the contained vascular injuries were visible in the CT arterial phase, whereas they were detectable in 28.5% of cases also during the venous phase (p = 0.02). All 13 cases of active bleeding were detected on the CT venous phase, and 76.9% of these cases were also revealed in the arterial phase, thus confirming their arterial origin (p = 0.22). CONCLUSION: The addiction of the arterial phase to the venous phase in the CT assessment of patients who underwent high-energy blunt trauma allows an accurate identification and characterization of traumatic vascular injuries, so distinguishing between patients suitable for conservative management and those requiring interventional or surgical treatment.


Assuntos
Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Lesões do Sistema Vascular/diagnóstico por imagem , Ferimentos não Penetrantes/diagnóstico por imagem , Adulto , Angiografia por Tomografia Computadorizada , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Fígado/irrigação sanguínea , Fígado/lesões , Masculino , Estudos Retrospectivos , Centros de Traumatologia
2.
Eur Radiol ; 27(2): 821-830, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27271922

RESUMO

OBJECTIVES: To demonstrate non-inferiority of iobitridol 350 for coronary CT angiography (CTA) compared to higher iodine content contrast media regarding rate of patients evaluable for the presence of coronary artery stenoses. METHODS: In this multicentre trial, 452 patients were randomized to receive iobitridol 350, iopromide 370 or iomeprol 400 and underwent coronary CTA using CT systems with 64-detector rows or more. Two core lab readers assessed 18 coronary segments per patient regarding image quality (score 0 = non diagnostic to 4 = excellent quality), vascular attenuation, signal and contrast to noise ratio (SNR, CNR). Patients were considered evaluable if no segment had a score of 0. RESULTS: Per-patient, the rate of fully evaluable CT scans was 92.1, 95.4 and 94.6 % for iobitridol, iopromide and iomeprol, respectively. Non-inferiority of iobitridol over the best comparator was demonstrated with a 95 % CI of the difference of [-8.8 to 2.1], with a pre-specified non-inferiority margin of -10 %. Although average attenuation increased with higher iodine concentrations, average SNR and CNR did not differ between groups. CONCLUSIONS: With current CT technology, iobitridol 350 mg iodine/ml is not inferior to contrast media with higher iodine concentrations in terms of image quality for coronary stenosis assessment. KEY POINTS: • Iodine concentration is an important parameter for image quality in coronary CTA. • Contrast enhancement must be balanced against the amount of iodine injected. • Iobitridol 350 is non-inferior compared to CM with higher iodine concentrations. • Higher attenuation with higher iodine concentrations, but no SNR or CNR differences.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Doença da Artéria Coronariana/diagnóstico por imagem , Método Duplo-Cego , Feminino , Humanos , Iodo , Iohexol/análogos & derivados , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 26(12): 4284-4292, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27121930

RESUMO

OBJECTIVES: The current gold standard in the assessment of lateral intracranial dural arteriovenous fistulas (LDAVF) is digital subtraction angiography (DSA). However, magnetic resonance imaging (MRI) is a non-invasive emerging tool for the evaluation of such lesions. The aim of our study was to compare the DSA to our 3 T MR-imaging protocol including a highly spatial resolved (ce-MRA) and a temporal resolved ("time-resolved imaging of contrast kinetics", TRICKS) contrast-enhanced MR angiography to evaluate if solely DSA can remain the gold-standard imaging modality for the treatment planning of LDAVF. METHODS: We retrospectively reviewed matched pairs of DSA and 3 T MRI examinations of 24 patients with LDAVF (03/2008-04/2014) by the same list of relevant criteria for an endovascular LDAVF treatment planning. In particular, we determined intermodality agreement for the Cognard classification, the identifeication of arterial feeders, and the detailed assessment of each venous drainage pattern. RESULTS: Intermodality agreement for the Cognard classification was excellent (ĸ = 1.0). Whereas MRI failed in identifying small arterial feeders, it was superior to the DSA in the assessment of the sinus and the venous drainage pattern. CONCLUSIONS: The combination of MRI and DSA is the new gold standard in LDAVF treatment planning. KEY POINTS: • DSA is superior to the MRI in detecting LDAVF arterial feeders. • MRI excellently evaluates the venous side of an LDAVF. • MRI can replace DSA in initial diagnosis and monitoring of LDAVF. • MRI and DSA combined are the new gold standard in LDAVF treatment planning.


Assuntos
Angiografia Digital/métodos , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Meios de Contraste/farmacocinética , Imageamento por Ressonância Magnética/métodos , Planejamento de Assistência ao Paciente , Adulto , Idoso , Feminino , Humanos , Aumento da Imagem , Iopamidol/análogos & derivados , Iopamidol/farmacocinética , Cinética , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
4.
Invest Radiol ; 51(3): 155-62, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26460826

RESUMO

OBJECTIVES: The aim of this study was to evaluate 4 nonionic x-ray iodinated contrast agents (CAs), commonly used in radiographic procedures, as novel chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) agents by assessing their in vitro exchange properties and preliminary in vivo use as tumor enhancing agents. MATERIALS AND METHODS: The CEST properties, as function of pH (range, 5.5-7.9) and of radio frequency conditions (irradiation field strength range of 1-9 µT and time of 1-9 seconds), have been determined at 7 T and 310 K for 4 x-ray CAs commonly used in clinical settings, namely, iomeprol, iohexol, ioversol, and iodixanol. Their in vivo properties have been investigated upon intravenous injection in a murine HER2+ breast tumor model (n = 4 mice for each CA) using both computed tomography (CT) and MRI modalities. RESULTS: The prototropic exchange rates measured for the 4 investigated iodinated molecules showed strong pH dependence with base catalyzed exchange rate that was faster for monomeric compounds (20-4000 Hz in the pH range of 5.5-7.9). Computed tomography quantification showed marked (up to 2 mg I/mL concentration) and prolonged accumulation (up to 30 minutes postinjection) inside tumor regions. Among the 4 agents we tested, iohexol and ioversol display good CEST contrast properties at 7 T, and in vivo results confirmed strong and prolonged contrast enhancement of the tumors, with elevated extravasation fractions (74%-91%). A strong and significant correlation was found between CT and CEST-MRI tumor-enhanced images (R = 0.70, P < 0.01). CONCLUSIONS: The obtained results demonstrate that iohexol and ioversol, 2 commonly used radiographic compounds, can be used as MRI perfusion agents, particularly useful when serial images acquisitions are needed to complement CT information.


Assuntos
Meios de Contraste/química , Imageamento por Ressonância Magnética , Neoplasias Mamárias Experimentais/diagnóstico , Tomografia Computadorizada por Raios X , Animais , Concentração de Íons de Hidrogênio , Técnicas In Vitro , Iohexol/química , Iopamidol/análogos & derivados , Iopamidol/química , Camundongos , Ácidos Tri-Iodobenzoicos/química
5.
J Comput Assist Tomogr ; 40(1): 80-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26466115

RESUMO

OBJECTIVE: The aim of the study was to evaluate objective and subjective image qualities of virtual monoenergetic imaging (VMI) in dual-source dual-energy computed tomography (DECT) and optimal kiloelectron-volt (keV) levels for lung cancer. METHODS: Fifty-nine lung cancer patients underwent chest DECT. Images were reconstructed as VMI series at energy levels of 40, 60, 80, and 100 keV and standard linear blending (M_0.3) for comparison. Objective and subjective image qualities were assessed. RESULTS: Lesion contrast peaked in 40-keV VMI reconstructions (2.5 ± 2.9) and 60 keV (1.9 ± 3.0), which was superior to M_0.3 (0.5 ± 2.7) for both comparisons (P < 0.001). Compared with M_0.3, subjective ratings were highest for 60-keV VMI series regarding general image quality (4.48 vs 4.52; P = 0.74) and increased for lesion demarcation (4.07 vs 4.84; P < 0.001), superior to all other VMI series (P < 0.001). Image sharpness was similar between both series. Image noise was rated superior in the 80-keV and M_0.3 series, followed by 60 keV. CONCLUSIONS: Virtual monoenergetic imaging reconstructions at 60-keV provided the best combination of subjective and objective image qualities in DECT of lung cancer.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
6.
Eur Heart J Cardiovasc Imaging ; 17(4): 458-66, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26219296

RESUMO

AIMS: To evaluate the feasibility of a non-contrast three-dimensional (3D)-FLASH magnetic resonance angiography (MRA) protocol for pre-procedural aortic annulus assessment for transcatheter aortic valve replacement (TAVR) in comparison with cardiac dual-source computed tomography angiography (CTA). METHODS AND RESULTS: In this prospective study, 69 of 104 consecutive patients (mean age 81.8 ± 5.4 years, 37.7% arrhythmic) with severe aortic stenosis who had undergone pre-TAVR cardiac CTA received a respiratory and ECG-triggered, non-contrast 3D-FLASH MRA at 3 T. Annular area measurements were obtained at mid-diastole for both modalities whereas maximum systolic area was assessed by CTA only. Systolic MRA dimensions were modelled, by adding the relative difference of systolic and diastolic CTA area dimensions as a corrective factor. Hypothetical prosthesis sizing was performed based on systolic CTA, diastolic, and modelled systolic MRA area measurements. MR image quality and degree of annular calcifications were evaluated using 4-point-grading scales. The mean acquisition time was 14 ± 4.2 min. The mean image quality was 3.1 ± 0.9 with only two examinations rated non-diagnostic. The mean degree of calcifications was equal. As assessed by Bland-Altman analysis, there was no relevant systematic difference between area measurements for modelled systolic MRA and systolic CTA [the mean difference -3.1 mm(2) (limits of agreement -44.4 mm(2); 38.2 mm(2))]. Agreement for hypothetical prosthesis sizing was found in 63 of 67 (94%) patients for systolic CTA and modelled systolic MRA. CONCLUSION: The employed non-contrast 3D-FLASH MRA protocol allows for reliable assessment of aortic annulus dimensions and calcifications even in the presence of arrhythmias in an all-comers pre-TAVR population. Implementation of this technique appears legitimate in patients at an increased risk for contrast-induced nephropathy.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Angiografia por Tomografia Computadorizada , Angiografia por Ressonância Magnética , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Diástole , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Iopamidol/análogos & derivados , Masculino , Cuidados Pré-Operatórios , Estudos Prospectivos , Sístole , Substituição da Valva Aórtica Transcateter
7.
Pediatr Radiol ; 45(6): 862-71, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25655368

RESUMO

BACKGROUND: Contrast-enhanced voiding urosonography (ce-VUS) is commonly requested simultaneously to other diagnostic imaging necessitating intravenous contrast agents. To date there is limited knowldedge about intravesical interactions between different types of contrast agents. OBJECTIVE: To assess the effect of excreted intravenous iodinated and gadolinium-based contrast agents on the intravesical distribution of ultrasound contrast within contrast-enhanced voiding urosonography. MATERIALS AND METHODS: Iodinated (iomeprol, iopamidol) and gadolinium-based (gadoterate meglumine) contrast agents were diluted to bladder concentration and injected into balloons filled with saline solution. CT scans were performed to assess the contrast distribution in these phantoms. Regions of interest were placed at the top and bottom side of each balloon and Hounsfield units (HU) were measured. Three other balloons were filled with saline solution and contrast media likewise. The ultrasound contrast agent sulphur hexafluoride was added and its distribution was assessed using sonography. RESULTS: MDCT scans showed a separation of two liquid layers in all bladder phantoms with the contrast layers located at the bottom and the saline solution at the top. Significant differences of the HU measurements at the top and bottom side were observed (P < 0.001-0.007). Following injection of ultrasound contrast agent, US showed its distribution exclusively among the saline solution. CONCLUSIONS: False-negative results of contrast-enhanced voiding urosonography may occur if it is performed shortly after imaging procedures requiring intravenous contrast.


Assuntos
Refluxo Vesicoureteral/diagnóstico por imagem , Administração Intravesical , Meios de Contraste , Reações Falso-Negativas , Humanos , Injeções Intravenosas , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Meglumina/administração & dosagem , Tomografia Computadorizada Multidetectores , Compostos Organometálicos/administração & dosagem , Imagens de Fantasmas , Hexafluoreto de Enxofre/administração & dosagem , Ultrassonografia
8.
Neuroradiology ; 56(10): 817-24, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25056099

RESUMO

INTRODUCTION: CT-angiography gains an increasing role in the initial diagnosis of patients with nontraumatic subarachnoid hemorrhage (SAH). However, the implementation of CT-angiography does not always exclude the necessity of conventional angiography. Our objective was to determine the practical utility and cost-effectiveness of CT-angiography. METHODS: All patients with nontraumatic subarachnoid hemorrhage admitted to our university hospital after implementation of CT-angiography between June 1, 2011 and June 30, 2012 were retrospectively analyzed in regard to factors of treatment flow, radiation exposure, harms of contrast medium loading, and diagnostic costs. A control group of the same size was assembled from previously admitted SAH patients, who did not undergo pretreatment CT-angiography. Furthermore, cost-effectiveness analysis was performed. RESULTS: The final analysis consisted of 93 patients in each group. Of 93 patients with pretreatment CT-angiography, 74 had to undergo conventional angiography for diagnostic and/or therapeutic purposes. CT-angiography had significant impact on the reduction of collective effective radiation dose by 4.419 mSv per person (p = 0.0002) and was not associated with additional harms. Despite the significantly earlier detection of aneurysms with CT-angiography (p < 0.0001), there were no significant differences in the timing of aneurysm repair and duration of ICU and general hospital stay. There was an increase of diagnostic costs-the cost-effectiveness analysis showed, however, that benefits of CT-angiography in respect to radiation exposure and risk of conventional angiography-related complications justify the additional costs of CT-angiography. CONCLUSIONS: Although the implementation of CT-angiography in SAH diagnosis cannot completely replace conventional angiography, it can be approved in regard to radiation hygiene and cost-effectiveness.


Assuntos
Angiografia Cerebral/economia , Aneurisma Intracraniano/diagnóstico por imagem , Hemorragia Subaracnóidea/diagnóstico por imagem , Tomografia Computadorizada por Raios X/economia , Adulto , Idoso , Meios de Contraste , Análise Custo-Benefício , Feminino , Humanos , Aneurisma Intracraniano/complicações , Aneurisma Intracraniano/terapia , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Anos de Vida Ajustados por Qualidade de Vida , Doses de Radiação , Estudos Retrospectivos , Hemorragia Subaracnóidea/etiologia , Hemorragia Subaracnóidea/terapia
9.
Rofo ; 186(6): 591-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24756426

RESUMO

PURPOSE: To evaluate a novel monoenergetic post-processing algorithm (MEI+) in patients with poor intrahepatic contrast enhancement. MATERIALS AND METHODS: 25 patients were retrospectively included in this study. Late-phase imaging of the upper abdomen, which was acquired in dual-energy mode (100/140 kV), was used as a model for poor intrahepatic contrast enhancement. Traditional monoenergetic images (MEI), linearly weighted mixed images with different mixing ratios (MI), sole 100 and 140 kV and MEI+ images were calculated. MEI+ is a novel technique which applies frequency-based mixing of the low keV images and an image of optimal keV from a noise perspective to combine the benefits of both image stacks. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the intrahepatic vasculature (IHV) and liver parenchyma (LP) were objectively measured and depiction of IHV was subjectively rated and correlated with portal venous imaging by two readers in consensus. RESULTS: MEI+ was able to increase the SNR of the IHV (5.7 ±â€Š0.4 at 40keV) and LP (4.9 ±â€Š1.0 at 90keV) and CNR (2.1 ±â€Š0.6 at 40keV) greatly compared to MEI (5.1 ±â€Š1.1 at 80keV, 4.7 ±â€Š1.0 at 80keV, 1.0 ±â€Š0.4 at 70keV), MI (5.2 ±â€Š1.1 M5:5, 4.8 ±â€Š1.0 M5:5, 1.0 ±â€Š3.5 M9:1), sole 100 kV images (4.4 ±â€Š1.0, 3.7 ±â€Š0.8, 1.0 ±â€Š0.3) and 140 kV images (2.8 ±â€Š0.5, 3.1 ±â€Š0.6, 0.1 ±â€Š0.2). Subjective assessment rated MEI+ of virtual 40 keV superior to all other images. CONCLUSION: MEI+ is a very promising algorithm for monoenergetic extrapolation which is able to overcome noise limitations associated with traditional monoenergetic techniques at low virtual keV levels and consequently does not suffer from a decline of SNR and CNR at low keV values. This algorithm allows an improvement of IHV depiction in the presence of poor contrast. KEY POINTS: • The evaluated new image-based algorithm for virtual monoenergetic imaging allows calculating low virtual keV images from dual energy datasets with significantly improved contrast-to-noise ratios. • The image based novel monoenergetic extrapolation algorithm applies frequency-based mixing of the low keV images and an image of optimal keV from a noise perspective to combine the benefits of both image stacks.• When compared to traditional monoenergetic images, the novel monoenergetic algorithm has improved contrast-to-noise ratios for both low and high virtual keV images.• Contrast-enhanced dual energy images with poor contrast conditions can be significantly improved, e.g. late phase imaging of the liver.


Assuntos
Algoritmos , Veias Hepáticas/diagnóstico por imagem , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Nefropatias/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
10.
Radiology ; 270(1): 74-81, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24009351

RESUMO

PURPOSE: To evaluate coronary arterial lesions and to assess their correlation with clinical findings in patients with Takayasu arteritis (TA) by using coronary computed tomographic (CT) angiography. MATERIALS AND METHODS: This retrospective study was approved by the hospital internal review board, and informed consent was waived. A total of 111 consecutive patients with TA (97 female, 14 male; mean age, 44 years ± 13.8 [standard deviation]; age range, 14-74 years) underwent CT angiography of the coronary arteries and aorta with 128-section dual-source CT. CT angiographic, clinical, and laboratory findings of each patient were retrospectively reviewed. Statistical differences between coronary CT angiographic findings and clinical parameters were examined with univariate analysis. RESULTS: Of 111 patients, 32 (28.8%) had cardiac symptoms and the remaining 79 (71.2%) had no cardiac symptoms. Fifty-nine patients (53.2%) had coronary arterial lesions at coronary CT angiography. Three main radiologic features were detected: coronary ostial stenosis (n = 31, 28.0%), nonostial coronary arterial stenosis (n = 41, 36.9%), and coronary aneurysm (n = 9, 8.1%). Coronary artery ostial or luminal stenosis of 50% or more or coronary aneurysms were observed in 26 (23.4%) patients with TA. Patients with coronary arterial abnormalities at coronary CT angiography had higher incidences of hypertension (P = .02), were older at the time of CT (P = .01), and had longer duration of TA (P = .02) than those without coronary artery abnormalities. The presence of cardiac symptoms, disease activity, and other comorbidities was not associated with differences in coronary artery involvement. CONCLUSION: In patients with TA, there is a high prevalence of coronary arterial abnormalities at coronary CT angiography, regardless of disease activity or symptoms. Thus, coronary CT angiography may add information on coronary artery lesions in patients with TA.


Assuntos
Angiografia Coronária/métodos , Arterite de Takayasu/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Arterite de Takayasu/patologia
11.
Radiol Med ; 119(4): 215-21, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24297581

RESUMO

PURPOSE: This study was undertaken to compare response evaluation criteria in solid tumours (RECIST) 1.1 and modified RECIST (mRECIST) in patients with unresectable hepatocellular carcinoma (HCC) on sorafenib, and to describe HCC enhancement changes before and after sorafenib treatment. METHODS AND MATERIALS: Seventeen patients (12 men, 5 women; mean age 69 years; age range 58-79 years) were included. Tumour response was assessed according to RECIST and mRECIST. Two readers placed a region of interest (ROI) within each target lesion, on the portion showing enhancement during the arterial phase. The lesion attenuation values measured within the ROIs on computed tomography or the signal intensity measured on magnetic resonance imaging, during the unenhanced phase, hepatic arterial phase and venous phase were recorded. Changes in arterial and venous contrast enhancement before and after treatment were compared among the mRECIST groups using Mann-Whitney U test. RESULTS: Agreement between mRECIST and RECIST was good (Cohen's k coefficient, 0.791). Patients with partial response had a greater decrease in arterial enhancement (-79.8%) than did patients with stable disease (SD) (-24.8%; p = 0.011) or progressive disease (PD) (-32.9%; p = 0.034). No statistically significant difference in arterial enhancement variation was found among patients with SD and PD. No statistically significant difference in venous enhancement was found among the mRECIST groups. CONCLUSIONS: mRECIST showed a more favourable response compared to RECIST 1.1 in patients with unresectable HCC receiving sorafenib.


Assuntos
Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/tratamento farmacológico , Imageamento por Ressonância Magnética , Niacinamida/análogos & derivados , Compostos de Fenilureia/uso terapêutico , Tomografia Computadorizada por Raios X , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Niacinamida/uso terapêutico , Compostos Organometálicos , Sorafenibe , Resultado do Tratamento
13.
Eur J Radiol ; 82(6): e255-61, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23414715

RESUMO

PURPOSE: Evaluate the diagnostic performance of contrast enhanced CT/PET (ceCT/PET) in the response assessment of patients with colorectal cancer liver metastases. METHODS: 33 ce CT/PET studies of 19 patients with colorectal liver metastases were prospectively evaluated. All of them, 13 (68.4%) were males and 6 (31.6%) females. Mean age and range were 63 [42-78]. All patients were treated with neoadjuvant chemotherapy. In all cases post-therapy diagnostic confirmation of liver lesions was obtained. A ce CT PET/was obtained 1h after the injection of 370 MBq of 18F-FDG. Metabolic and morphologic studies were evaluated by two blinded nuclear physicians and radiologists respectively to assess the location, size and suspected diagnosis of lesions (benign or malignant). A combined assessment of both techniques was performed. The final diagnosis was established by histopathology or clinical/radiological follow-up greater than 6 months. RESULTS: A total of 120 liver lesions were identified, 115 were malignant and 5 benign. From the malignant lesions, 105 were identified with the ceCT, 44 with the PET and 109 with ceCT/PET. All of the benign lesions were correctly classified with any of the three imaging techniques. The sensitivity of PET, ceCT and ceCT/PET were of 38%, 91% and 95% respectively and the specificity was 100% in all three of the diagnostic studies. CONCLUSION: Administration of intravenous contrast in the PET/CT is mandatory to evaluate treatment response rate of liver metastases due to the limitations of isolated metabolic images in these cases.


Assuntos
Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/terapia , Fluordesoxiglucose F18 , Iopamidol/análogos & derivados , Neoplasias Hepáticas , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/terapia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha , Resultado do Tratamento
14.
Radiol Med ; 118(1): 140-51, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22430675

RESUMO

PURPOSE: The aim of our study was to compare the relative cerebral blood volume (CBV) values obtained by first-pass dynamic susceptibility-weighted contrast-enhanced (DSC) T2-weighted magnetic resonance (MR) and perfusion computed tomography (P-CT) imaging in high-grade gliomas (HGG) in the same patient population. MATERIALS AND METHODS: Sixteen patients with histologically proven HGG underwent P-CT and DSC-MR brain imaging. P-CT studies were obtained using a four-row multislice CT scanner and postprocessed with a commercial software package based on a deconvolution-based technique. DSC-MR images were obtained at 1.5 T with a first-pass dynamic susceptibility contrast-enhanced T2-weighted sequence. P-CT and DSC-MR images were obtained within 4 days of each another, always before surgery. Maximum CBV ratios normalised with contralateral white matter (rCBV) were calculated. Statistical analysis was performed with the classical parametric statistic procedure. RESULTS: A linear correlation between maximum rCBV values obtained with P-CT and DSC-MR imaging was evident. The best linear model is CT=slope×MR+error and provides a highly significant estimate of the slope equal to 1.08. Thus CT results can be predicted from MR values. Therefore, it is also possible to predict MR results from CT values by estimating the linear model MR=slope×CT+error. DSC-MR imaging gave lower rCBV average values (4.92±1.52) compared with P-CT (5.56±1.55). CONCLUSIONS: In our population of patients, P-CT and DSC-MR imaging showed proportional results in rCBV assessment of HGGs, and thus both modalities may be used interchangeably in HGG of the brain.


Assuntos
Neoplasias Encefálicas/diagnóstico , Glioma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Glioma/diagnóstico por imagem , Glioma/patologia , Humanos , Interpretação de Imagem Assistida por Computador , Iopamidol/análogos & derivados , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Software
15.
Br J Radiol ; 86(1021): 20120238, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255542

RESUMO

OBJECTIVE: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. METHODS: In six ex vivo left anterior descending coronary arteries immersed in oil, CT (slices/collimation 64×0.625 mm, temporal resolution 210 ms, pitch 0.2) was performed after intracoronary injection of a saline solution, and solutions of a dimeric isosmolar contrast medium (Iodixanol 320 mgI ml(-1)) and a monomeric high-iodinated contrast medium (Iomeprol 400 mgI ml(-1)) with dilutions of 1/80 (low concentration), 1/50 (medium concentration), 1/40 (high concentration) and 1/20 (very high concentration). Two radiologists drew regions of interest in the lumen and in calcified and non-calcified plaques for each solution. 29 cross-sections with non-calcified plaques and 32 cross-sections with calcified plaques were evaluated. RESULTS: Both contrast media showed different attenuation values within lumen and plaque (p<0.0001). The correlation between lumen and non-calcified plaque values was good (Iodixanol r=0.793, Iomeprol r=0.647). Clustered medium- and high-concentration solutions showed similar plaque attenuation values, signal-to-noise ratios (SNRs) (non-calcified plaque: medium solution SNR 31.3±15 vs 31.4±20, high solution SNR 39.4±17 vs 37.4±22; calcified plaque: medium solution SNR 305.2±133 vs 298.8±132, high solution SNR 323.9±138 vs 293±123) and derived contrast-to-noise ratios (p>0.05). CONCLUSION: Differently iodinated contrast media have a similar influence on plaque attenuation profiles. ADVANCES IN KNOWLEDGE: Since iodine load affects coronary plaque attenuation linearly, different contrast media may be equally employed for coronary atherosclerotic plaque imaging.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Iopamidol/análogos & derivados , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Técnicas In Vitro , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ácidos Tri-Iodobenzoicos/administração & dosagem
16.
Eur J Radiol ; 82(2): 327-34, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23246016

RESUMO

OBJECTIVES: To investigate the volumetric iodine-uptake (VIU) changes by dual-energy CT (DECT) in assessing the response to sorafenib treated hepatocellular carcinoma (HCC) patients, compared with AASLD (American Association for the Study of Liver Diseases) and Choi criteria. MATERIALS AND METHODS: Fifteen patients with HCC receiving sorafenib, monitored with contrast-enhanced DECT scans at baseline and a minimum of one follow-up (8-12 weeks) were retrospectively evaluated. 30 target lesions in total were analyzed for tumor response according to VIU and adapted Choi criteria and compared with the standard AASLD. RESULTS: According to AASLD criteria, 67% target lesions showed disease control: partial response (PR) in 3% and stable disease (SD) in 63%. 33% lesions progressed (PD). Disease control rate presented by VIU (60%) was similar to AASLD (67%) and Choi (63%) (P>0.05). For disease control group, change in mean VIU was from 149.5 ± 338.3mg to 108.5 ± 284.1mg (decreased 19.1 ± 42.9%); and for progressive disease group, change in mean VIU was from 163.7 ± 346.7 mg to 263.9 ± 537.2 mg (increased 230.5 ± 253.1%). Compared to AASLD (PR, 3%), VIU and Choi presented more PR (33% and 30%, respectively) in disease control group (P<0.05). VIU has moderate consistency with both AASLD (kappa=0.714; P<0.005) and Choi (kappa=0.648; P<0.005), while VIU showed a better consistency and correlation with AASLD (kappa=0.714; P<0.005; r=0.666, P<0.005) than Choi with AASLD (kappa=0.634, P<0.005; r=0.102, P=0.296). CONCLUSION: VIU measurements by DECT can evaluate the disease control consistent with the current standard AASLD. Measurements are semi-automatic and therefore easy and robust to apply. As VIU reflects vital tumor burden in HCC, it is likely to be an optimal tumor response biomarker in HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/tratamento farmacológico , Iopamidol/análogos & derivados , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Niacinamida/análogos & derivados , Compostos de Fenilureia/uso terapêutico , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/uso terapêutico , Carcinoma Hepatocelular/metabolismo , Meios de Contraste/farmacocinética , Feminino , Humanos , Imageamento Tridimensional/métodos , Iopamidol/farmacocinética , Neoplasias Hepáticas/metabolismo , Masculino , Pessoa de Meia-Idade , Niacinamida/uso terapêutico , Avaliação de Resultados em Cuidados de Saúde/métodos , Projetos Piloto , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sorafenibe , Resultado do Tratamento
17.
Acta Radiol ; 53(9): 1014-9, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22993268

RESUMO

BACKGROUND: Determination of disease activity of chronic destructive pulmonary tuberculosis (TB) on imaging studies can be difficult because several imaging findings due to disease chronicity such as a residual cavity can be misinterpreted as an active disease. PURPOSE: To evaluate computed tomography (CT) findings to predict active disease in patients with chronic destructive pulmonary TB. MATERIAL AND METHODS: CT findings of 36 patients with chronic active destructive pulmonary TB and 78 patients with chronic inactive destructive pulmonary TB were reviewed and their patterns of lung lesions were compared. Statistical comparisons were performed using chi-square and Student's T tests for univariate analyses, and a stepwise logistic regression method was used for multivariate analysis. RESULTS: Based on univariate analyses, cavitary destruction (P = 0.015), non-branching centrilobular nodules (P < 0.001), tree-in-bud pattern (P < 0.001), airspace nodules (P < 0.001), and cavities in other lobes (P = 0.001) were more frequently seen in chronic active destructive pulmonary TB. A stepwise logistic regression analysis demonstrated that tree-in-bud pattern (odds ratio, 52.3; 95% confidence interval, 6.2-437.2; P < 0.001) were significant CT findings associated with active disease. CONCLUSION: Tree-in-bud pattern were the most characteristic CT findings to predict active disease in patients with chronic destructive pulmonary TB.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Tuberculose Pulmonar/diagnóstico por imagem , Idoso , Distribuição de Qui-Quadrado , Doença Crônica , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Iopamidol/análogos & derivados , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
18.
Korean J Radiol ; 13(1): 27-33, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22247633

RESUMO

OBJECTIVE: We aimed to describe the imaging findings of multidetector CT coronary angiography (MDCTA) in cases of vasospastic angina (VA) and to determine the accuracy of MDCTA in the identification of VA as compared with invasive coronary angiography with an ergonovine provocation test (CAG with an EG test). MATERIALS AND METHODS: Fifty-three patients with clinically suspected VA were enrolled in this study. Two radiologists analyzed the stenosis degree, presence or absence of plaque, plaque composition, and a remodeling index of the related-segment in CAG with an EG test, which were used as a gold standard. We evaluated the diagnostic performances of MDCTA by comparing the MDCTA findings with those of CAG with an EG test. RESULTS: Among the 25 patients with positive CAG with an EG test, all 12 patients with significant stenosis showed no definite plaque with the negative arterial remodeling. Of the six patients with insignificant stenosis, three (50%) had non-calcified plaque (NCP), two (33%) had mixed plaque, and one (17%) had calcified plaque. When the criteria for significant stenosis with negative remodeling but no definite evidence of plaque as a characteristic finding of MDCTA were used, results showed sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) of 48%, 100%, 100%, and 68%, respectively. CONCLUSION: Significant stenosis with negative remodeling, but no definite evidence of plaque, is the characteristic finding on MDCTA of VA. Cardiac MDCTA shows good diagnostic performance with high specificity and PPV as compared with CAG with an EG test.


Assuntos
Angina Pectoris/diagnóstico por imagem , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Distribuição de Qui-Quadrado , Comorbidade , Meios de Contraste , Eletrocardiografia , Ergonovina , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Ocitócicos , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Eur Radiol ; 22(3): 569-78, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21984448

RESUMO

OBJECTIVES: To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. METHODS: Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. RESULTS: Estimates for mean relative ED was 7.1 ± 2.1 mSv/100 mAs for TCM and 12.5 ± 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR (≤60 bpm) was highest (49 ± 5%) compared to intermediate (60-70 bpm, 33 ± 12%) and high HR (>70 bpm, 29 ± 12%). However lowest ED is achieved at high HR (5.2 ± 1.5 mSv/100 mAs), compared with intermediate (6.7 ± 1.6 mSv/100 mAs) and low (8.3 ± 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. CONCLUSIONS: Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. KEY POINTS: • Monte Carlo simulations allow for individual radiation dose calculations. • ECG-triggered tube current modulation (TCM) can effectively reduce radiation dose. • Slow and regular heart rates allow for highest dose reductions by TCM. • Adaptive pitch accounts for lowest radiation dose at high heart rates. • Women receive higher effective dose than men undergoing spiral coronary CT-angiography.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Método de Monte Carlo , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iopamidol/análogos & derivados , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais
20.
Int J Cardiovasc Imaging ; 27 Suppl 1: 27-35, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22113322

RESUMO

We aimed to investigate the prevalence and severity of noncalcified coronary plaques (NCP) using coronary CT angiography (CCTA) and analyze predictors of significant coronary stenosis by NCP in asymptomatic subjects with low coronary artery calcium score (CACS). The institutional review board approved this retrospective study and all patients gave written, informed consent. The presence of plaque, severity of stenosis, plaque characteristics, and CACS were assessed in 7,515 asymptomatic subjects. We evaluated the prevalence and severity of NCP in subjects having low CACS (707 subjects; men with CACS from 1 to 50 and women from 1 to 10) in comparison to those having 0 CACS (6,040 subjects) as the reference standard. Conventional risk factors were assessed for predictors of NCP and significant stenosis by NCP. We also investigated the cardiac events of the patients through medical records. Compared to subjects with 0 CACS, those with low CACS showed higher prevalence of NCP (6.9% vs. 31.5%, P < 0.001) and significant stenosis caused by NCP (0.8% vs. 7.5%, P < 0.001). In the low CACS group, independent predictors for significant NCP included diabetes mellitus (DM), hypertension, and elevated low-density lipoprotein (LDL)-cholesterol (all P < 0.05). However, 47.2% of subjects with significant NCP were classified into the low to intermediate risk according to Framingham Risk Score. At the median follow up of 42 months (range: 3-60 months), cardiac events were significantly higher in the low CACS group compared to the 0 CACS group (2.6% vs. 0.27%, P < 0.001). In asymptomatic subjects having low CACS, the prevalence and severity of NCP were higher as compared to subjects having zero CACS and predictors of significant stenosis by NCP were DM, hypertension and LDL-Cholesterol. Therefore, CCTA may be useful for risk stratification of coronary artery disease as added value over CACS in selected populations with low CACS who have predictors of significant NCP.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Calcinose/epidemiologia , Meios de Contraste , Estenose Coronária/epidemiologia , Feminino , Seguimentos , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/epidemiologia , Valor Preditivo dos Testes , Prevalência , Intensificação de Imagem Radiográfica/métodos , República da Coreia/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Tomografia Computadorizada de Feixe Cônico Espiral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA