1.
Int J Oral Maxillofac Implants ; 39(2): 320, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38457263

RESUMO

PURPOSE: To investigate the biocompatibility of silver nanoparticle (AgNP)-doped Ti-6Al-4V surfaces by evaluating the viability and proliferation rate of human gingival fibroblasts (HGFs)-as the dominant cells of peri-implant soft tissues-seeded on the modified surfaces. MATERIALS AND METHODS: AgNPs (sizes 8 nm and 30 nm) were incorporated onto Ti-6Al-4V specimen surfaces via electrochemical deposition, using colloid silver dispersions with increasing AgNP concentrations of 100 ppm, 200 ppm, and 300 ppm. One control and six experimental groups were included in the study: (1) control (Ti-6Al-4V), (2) 8 nm/100 ppm, (3) 8 nm/200 ppm, (4) 8 nm/300 ppm, (5) 30 nm/100 ppm, (6) 30 nm/200 ppm, and (7) 30 nm/300 ppm. HGF cell primary cultures were isolated from periodontally healthy donor patients and cultured in direct contact with the group specimens for 24 and 72 hours. The cytotoxicity of AgNP-doped Ti-6Al-4V specimens toward HGF was assessed by the MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) and BrdU (5-bromo-2'-deoxyuridine) assay tests. Calcein AM and ethidium homodimer (EthD-1) fluorescent stains were used to determine the live and dead cells. The morphology and attachment properties of the HGFs were determined via scanning electron microscopy (SEM). RESULTS: Energy dispersive x-ray (EDX) analysis confirmed the presence of AgNPs on the specimens. The MTT test revealed that AgNPs of both sizes and all concentrations presented a decreased cellular metabolic activity compared to the control discs. All concentrations of both sizes of AgNPs affected the cell proliferation rate compared to the control group, as revealed by the BrdU assay. Overall, cytotoxicity of the modified Ti-6Al-4V surfaces depended on cell exposure time. Observation via confocal microscopy confirmed the results of the MTT and BrdU assay tests. Specifically, most cells remained alive throughout the 72-hour culture period. SEM images revealed that adjacent cells form bonds with each other, creating confluent layers of conjugated cells. CONCLUSIONS: The findings of the present study indicate that Ti-6Al-4V surfaces modified with 8 nm and 30 nm AgNPs at concentrations of 100 ppm, 200 ppm, and 300 ppm do not produce any serious cytotoxicity toward HGFs. The initial arrest of the HGF proliferation rate recovered at 72 hours. These results on the antibacterial activity against common periodontal pathogens, in combination with the results found in a previous study by the same research group, suggest that AgNP-doped Ti-6Al-4V surfaces are potential candidates for use in implant abutments for preventing peri-implant diseases.


Assuntos
Ligas , Proliferação de Células , Sobrevivência Celular , Fibroblastos , Gengiva , Nanopartículas Metálicas , Prata , Propriedades de Superfície , Tiazóis , Titânio , Humanos , Fibroblastos/efeitos dos fármacos , Titânio/toxicidade , Titânio/química , Gengiva/citologia , Gengiva/efeitos dos fármacos , Prata/química , Prata/toxicidade , Proliferação de Células/efeitos dos fármacos , Nanopartículas Metálicas/toxicidade , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Ligas/toxicidade , Teste de Materiais , Ligas Dentárias/química , Ligas Dentárias/toxicidade , Microscopia Eletrônica de Varredura , Corantes , Materiais Biocompatíveis/química , Sais de Tetrazólio
2.
NanoImpact ; 28: 100442, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36436823

RESUMO

Establishing toxicological predictive modeling frameworks for heterogeneous nanomaterials is crucial for rapid environmental and health risk assessment. However, existing structure-toxicity correlation models for such nanomaterials are only based on simple linear regression algorithms that are prone to underfitting the training data. These models rely heavily on experimental and expensive computational quantum mechanical descriptors, which significantly limit their practical use. Herein, we present the application of empirical descriptors and complex machine learning algorithms to the development of high-performance quantitative structure-toxicity relationship (QSTR) models of TiO2 hybridized with multi-metallic (Ag, Au, Pt) alloy nanoparticles (multi-metallic NPs/TiO2). To confirm the viability of empirical descriptors as model input, we selected five distinct machine learning algorithms for predicting the toxicity of multi-metallic alloy NPs/TiO2 system in Chinese hamster ovary cell line. Notably, an empirical descriptor-based QSTR model (kernel ridge regression) revealed a predictive performance that is on par with density functional theory (DFT) descriptor-based counterparts. More specifically, the results indicated that model selection is influenced by descriptor choice, such that complex DFT descriptors worked best with a complex algorithm (random forest regression; RMSET = 0.0954, MAET = 0.0811, RT2 = 0.9411), whereas more straightforward empirical descriptors were most suitable with a simpler algorithm (kernel ridge regression; RMSET = 0.1244, MAET = 0.1106, RT2 = 0.8999). Moreover, our model outperforms existing QSAR models built on the same data set. This study offers a new perspective on using empirical features to develop accurate predictive computational models for the rapid discovery and profiling of safe-by-design nanomaterials.


Assuntos
Ligas , Aprendizado de Máquina , Cricetinae , Animais , Ligas/toxicidade , Células CHO , Cricetulus
3.
Regul Toxicol Pharmacol ; 133: 105227, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35817207

RESUMO

Stainless steels are widely used iron-based alloys that contain chromium and, typically, other alloying elements. The chromium(III)-rich surface oxide of stainless steels efficiently limits the release (bioaccessibility) of their metal constituents in most physiological environments, influencing the toxicity of the alloy. Of the constituents and impurities of stainless steels, nickel and cobalt are of particular interest, primarily due to skin sensitization and repeated-dose inhalation toxicity of nickel, and (inhalation) carcinogenicity of cobalt. A review of the available toxicological data on stainless steels, and the toxicological, mechanistic, and bioaccessibility data on their constituent metals supports the low toxicity and non-carcinogenicity of stainless steels. The comparative metal release, rather than the bulk composition of stainless steels, needs to be considered when assessing their health hazard classification according to the UN Globally Harmonized System, and the corresponding EU CLP regulation. As an illustrative example, a 28-day inhalation toxicity study on stainless steel powder showed no signs of lung toxicity at exposure levels at which significant toxicity would have been expected on the basis of its bulk nickel content. This finding is associated with the low bioaccessibility of nickel from the alloy in the lungs.


Assuntos
Níquel , Aço Inoxidável , Ligas/toxicidade , Cromo/toxicidade , Cobalto , Níquel/toxicidade , Aço Inoxidável/toxicidade , Aço
4.
Ann Biol Clin (Paris) ; 76(2): 165-172, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29623886

RESUMO

Silver cutlery and serving dishes are a potential source of exposure of humans that was never quantified. Release of silver was assessed in vitro in an acidic solution mimicking food fluid in two conditions: i] the JRC guidelines for hot fill conditions with stable high temperature over a 2 hour-period of time, and ii] a more realistic condition with spontaneous progressive decline from 90̊C to ambient temperature over the same period of time. Massive silver 95% strips were exposed to a 5% citric acid solution: i) cooling down from 90̊C to ambient or ii) 70̊C maintained, during 2 hours. Spectrometry with optical emission was used to measure silver in solution. In the spontaneous cooling down study, the time-course of temperature was close to the Newton's law of cooling and the released quantities were detected but too low to be measured. The 70̊C exposition resulted in a non-linear release that became quantifiable after one hour of heating up to an apparent plateau at 120 min with a mean concentration [extreme] of 24.6 [22.3-26.8] µg/L. The results of the present study allow concluding that 95% silver used for cutlery and serving dishes may be released in foods. However, the extent of release depends on the condition of use. At a stable 70̊C temperature over a 2 h-period of time, silver is released in a non-linear model up to a mean concentration of 24.6 µg/L. In contrast, in conditions fitting with the routine recommendations of use, infinitesimal detectable amounts of silver were released.


Assuntos
Utensílios de Alimentação e Culinária , Ingestão de Alimentos/fisiologia , Contaminação de Alimentos/análise , Prata/administração & dosagem , Atividades Cotidianas , Ligas/administração & dosagem , Ligas/toxicidade , Poluição Ambiental/análise , Humanos , Limite de Detecção , Refeições , Nível de Efeito Adverso não Observado , Prata/toxicidade , Temperatura
5.
Acta Biomater ; 26: 366-76, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26283166

RESUMO

The microstructures, mechanical properties and biocompatibility of low cost ß-type Ti-(6-18)Mn alloys were investigated after solution treatment. Ti-9 Mn exhibits the best combination of tensile strength and elongation among the fabricated alloys, and its performance is comparable to or superior to those of Ti-6Al-4V ELI (Ti-64 ELI) in terms of every parameter evaluated. A hardness of 338 HV, a Young's modulus of 94 GPa, a 0.2% proof stress of 1023 MPa, an ultimate tensile strength of 1048 MPa and elongation of 19% were obtained for Ti-9 Mn. Furthermore, the cell viability and metallic ion release ratios are comparable to those of commercially pure titanium, making this alloy promising for biomedical applications. The Young's modulus is also lower than that of Ti-64 ELI (110 GPa), which can possibly reduce the stress shielding effect in implanted patients. STATEMENT OF SIGNIFICANCE: This study evaluates mechanical and biological performance of low cost solution treated ß-type Ti-(6, 9, 13 and 18 mass%)Mn alloys. It includes alloys containing a Mn content range higher than most previously published works (which is around or lower than 8 mass%). Furthermore, the effects of the ω phase and the ß phase stability of the alloys over some mechanical properties and microstructures are discussed. Ion release behavior under simulated body fluids and cell viability are also evaluated. For the case of the Ti-9 Mn, a mechanical and biological performance that is comparable to or superior than that of the widely used Ti-6Al-4V ELI and commercially pure Ti was observed.


Assuntos
Apoptose/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Manganês/química , Manganês/toxicidade , Titânio/química , Titânio/toxicidade , Células 3T3 , Ligas/química , Ligas/toxicidade , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Força Compressiva , Módulo de Elasticidade , Dureza , Teste de Materiais , Camundongos , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
6.
Proc Inst Mech Eng H ; 229(5): 335-42, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25991712

RESUMO

This article reports the in vitro degradation and cytotoxicity assessment of Zn-3Mg alloy developed for biodegradable bone implants. The alloy was prepared using casting, and its microstructure was composed of Mg2Zn11 intermetallic phase distributed within a Zn-rich matrix. The degradation assessment was done using potentiodynamic polarization and electrochemical impedance spectrometry. The cell viability and the function of normal human osteoblast cells were assessed using 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium and alkaline phosphatase extracellular enzyme activity assays. The results showed that the degradation rate of the alloy was slower than those of pure Zn and pure Mg due to the formation of a high polarization resistance oxide film. The alloy was cytocompatible with the normal human osteoblast cells at low concentrations (<0.5 mg/mL), and its alkaline phosphatase activity was superior to pure Mg. This assessment suggests that Zn-3Mg alloy has the potential to be developed as a material for biodegradable bone implants, but the toxicity limit must be carefully observed.


Assuntos
Implantes Absorvíveis , Ligas/química , Materiais Biocompatíveis/química , Magnésio/química , Zinco/química , Ligas/toxicidade , Materiais Biocompatíveis/toxicidade , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Humanos , Magnésio/toxicidade , Osteoblastos/efeitos dos fármacos , Zinco/toxicidade
7.
J Mater Sci Mater Med ; 25(1): 163-72, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24022801

RESUMO

The use of biocompatible materials has attained an increasing importance for tissue regeneration and transplantation. The excellent mechanical and corrosion properties of Ti40Cu38Zr10Pd12 bulk metallic glass (BMG) turn it into a potential candidate for its use in orthopaedic implants. Before being considered as a biomaterial, some biological parameters must be taken into account. In this study,mouse preosteoblasts were cultured in the presence or absence of the alloy at different times (24 h, 7 and 21 days) and no differences in cell viability were detected.Moreover, cells were able to adhere to the alloy surface by establishing focal contacts, and displayed a flattened polygonal morphology. After 14 days in culture, differentiation into osteoblasts was observed. Besides, the amount of Cu ions released and their potential toxic effects were analyzed, showing that the amount of Cu released did not increase cell death. Finally, the low levels of inflammatory cytokines secreted by THP-1 differentiated macrophages exposed to the alloy suggest the absence of an immunogenic response to the alloy. In conclusion, in vitro studies indicate that the Ti40Cu38Zr10Pd12 BMG could be considered as a biomaterial to be used in orthopaedic implants.


Assuntos
Ligas/química , Ligas/toxicidade , Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Vidro/química , Células 3T3 , Animais , Adesão Celular/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Cobre/análise , Cobre/toxicidade , Citocinas/biossíntese , Humanos , Macrófagos/efeitos dos fármacos , Macrófagos/imunologia , Teste de Materiais , Camundongos , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Próteses e Implantes
8.
Biomed Eng Online ; 11: 14, 2012 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-22429539

RESUMO

BACKGROUND: Most studies on biodegradable magnesium implants published recently use magnesium-calcium-alloys or magnesium-aluminum-rare earth-alloys.However, since rare earths are a mixture of elements and their toxicity is unclear, a reduced content of rare earths is favorable. The present study assesses the in vivo biocompatibility of two new magnesium alloys which have a reduced content (ZEK100) or contain no rare earths at all (AX30). METHODS: 24 rabbits were randomized into 4 groups (AX30 or ZEK100, 3 or 6 months, respectively) and cylindrical pins were inserted in their tibiae. To assess the biodegradation µCT scans and histological examinations were performed. RESULTS: The µCT scans showed that until month three ZEK100 degrades faster than AX30, but this difference is leveled out after 6 months. Histology revealed that both materials induce adverse host reactions and high numbers of osteoclasts in the recipient bone. The mineral apposition rates of both materials groups were high. CONCLUSIONS: Both alloys display favorable degradation characteristics, but they induce adverse host reactions, namely an osteoclast-driven resorption of bone and a subsequent periosteal formation of new bone. Therefore, the biocompatibility of ZEK100 and AX30 is questionable and further studies, which should focus on the interactions on cellular level, are needed.


Assuntos
Ligas/metabolismo , Ligas/toxicidade , Magnésio/metabolismo , Magnésio/toxicidade , Teste de Materiais/métodos , Modelos Animais , Animais , Medula Óssea/diagnóstico por imagem , Medula Óssea/efeitos dos fármacos , Medula Óssea/metabolismo , Minerais/metabolismo , Próteses e Implantes/efeitos adversos , Coelhos , Coloração e Rotulagem , Cloreto de Tolônio/metabolismo , Microtomografia por Raio-X
9.
Acta Biomater ; 6(5): 1808-12, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-19969109

RESUMO

The theoretical tolerable implant masses for ten magnesium alloys as degradable biomedical implant materials are evaluated in this study. Dose-response assessment is conducted using toxicological data from authoritative public health agencies such as the US Agency for Toxic Substances and Disease Registry and the USEPA Integrated Risk Information System, and assuming 1 year of even corrosion. Uncertainty factors adopted by the agencies are used. The tolerable limits corresponding to various component elements in an alloy are considered separately, and the lowest tolerable limit is selected as the tolerable limit of the alloy. The results show that aluminum is usually the component element with the lowest tolerance, and the tolerable mass for Al-containing magnesium alloys fall to around or below 1g per person per year, while the limit for other magnesium alloys can well exceed 10 g. Deficits in the toxicological data of some component elements are noted. This study illustrates that toxicological calculations should be taken into consideration when developing novel degradable metallic implants.


Assuntos
Implantes Absorvíveis , Ligas/toxicidade , Materiais Biocompatíveis/toxicidade , Magnésio/toxicidade , Medição de Risco
10.
Biomol Eng ; 19(2-6): 153-60, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12202176

RESUMO

Orthodontic arcs and wires are mostly realised from alloys and constitute the motor of dental shifting. Ti-base alloys rapidly replaced the formerly used stainless steel wires due to their excellent corrosion resistance, their high mechanical characteristics and their increased biocompatibility. NiTiNOL shape memory alloys add to these advantages their ability of deforming force. NiTiNOL, highly pure Nickel (hp-Ni) and commercially pure titanium (cp-Ti) were tested by electrochemical assays in artificial saliva and in vitro biological tests with L132 cells and HEPM cells. All tests gave concordant results: the electrochemical assays, the proliferation test, the colony forming method, and the inflammatory test clearly show, that nickel is a corrosive and a cytotoxic material. Ti and NiTiNOL are cytocompatible and in particular corrosion resistant. No significant differences are observed for both materials on the electrochemical and the biological level as well. The NiTiNOL shape memory alloy is a master trump for dental practitioners to repair occlusal defects by shifting teeth under optimal biological conditions. In spite of its high Ni-content, it is biocompatible. It considerably reduces the tune of therapeutic treatment, facilitate the occlusal concept and leads to a result of high clinical quality.


Assuntos
Ligas/química , Ligas/toxicidade , Células Epiteliais/patologia , Teste de Materiais/métodos , Fios Ortodônticos , Palato/patologia , Adesão Celular/efeitos dos fármacos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Eletroquímica , Células Epiteliais/imunologia , Humanos , Dose Letal Mediana , Mesoderma/patologia , Níquel/química , Níquel/toxicidade , Palato/embriologia , Titânio/química , Titânio/toxicidade
11.
Biomaterials ; 22(16): 2215-28, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11456061

RESUMO

The composition of ionically dissolved and precipitated corrosion products from both free corrosion of ASTM F75 Co-Cr-Mo and galvanostatic polarization of Co-Cr-Mo and F138 316L stainless steel was determined using differential pulse polarography and inductively coupled plasma atomic emission spectroscopy. A bacterial bioluminescence assay, Microtox, was used to assess the toxicity of the solid and dissolved corrosion products produced by galvanostatic polarization and the individual ions within them. The role of in vivo salinity, temperature, and protein content as modulators of corrosion product toxicity assessment was investigated empirically and mechanistically. Co-Cr-Mo products were found to be more toxic than those of 316L, and the most toxic ions were Cr6+, Ni2+, and Co2+. Ringer's solution potentiated the toxicity of the more toxic metal ions and reduced the toxicity of the less toxic ions. Using theoretical analysis in conjunction with experimental measurements, the ions in both alloys were found to interact in an antagonistic fashion. The presence of albumin was found to decrease metal toxicity, presumably by chelation.


Assuntos
Ligas/toxicidade , Materiais Biocompatíveis/toxicidade , Albuminas , Animais , Bovinos , Quelantes , Corrosão , Técnicas In Vitro , Soluções Isotônicas , Medições Luminescentes , Teste de Materiais , Próteses e Implantes , Solução de Ringer , Aço Inoxidável/toxicidade , Temperatura