Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 525
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Scand J Gastroenterol ; 59(8): 989-995, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38742832

RESUMO

BACKGROUND AND AIM: To explore the feasibility of a standardized training and assessment system for magnetically controlled capsule gastroscopy (MCCG). METHODS: The results of 90 trainees who underwent the standardized training and assessment system of the MCCG at the First Affiliated Hospital of Xi'an Jiaotong University from May 2020 to November 2023 was retrospectively analyzed. The trainees were divided into three groups according to their medical backgrounds: doctor, nurse, and non-medical groups. The training and assessment system adopted the '7 + 2' mode, seven days of training plus two days of theoretical and operational assessment. The passing rates of theoretical, operational, and total assessment were the primary outcomes. Satisfaction and mastery of the MCCG was checked. RESULTS: Ninety trainees were assessed; theoretical assessment's passing rates in the three groups were 100%. The operational and total assessment passing rates were 100% (25/25), 97.92% (47/48), and 94.12% (16/17), for the doctor, nurse, and non-doctor groups respectively, with no significant difference (χ2 = 1.741, p = 0.419). No bleeding or perforation occurred during the procedure. Approximately, 96.00% (24/25), 95.83% (46/48), and 94.12% (16/17) of the doctor, nurse and non-medical groups anonymously expressed great satisfaction, respectively, without statistically significant difference (χ2 = 0.565, p = 1.000). The average follow-up time was 4-36 months, and 87 trainees (96.67%) had mastered the operation of the MCCG in daily work. CONCLUSIONS: Standardized training and assessment of magnetically controlled capsule endoscopists is effective and feasible. Additionally, a strict assessment system and long-term communication and learning can improve teaching effects.


Assuntos
Endoscopia por Cápsula , Competência Clínica , Gastroscopia , Humanos , Gastroscopia/educação , Gastroscopia/métodos , Estudos Retrospectivos , Feminino , Masculino , Endoscopia por Cápsula/métodos , Endoscopia por Cápsula/educação , Adulto , Estudos de Viabilidade , Avaliação Educacional/métodos , Magnetismo , China
2.
PLoS One ; 18(8): e0289543, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37540637

RESUMO

The competitive balance model was proposed as an extension of the structural balance theory, aiming to account for heterogeneities observed in real-world networks. In this model, different paradigms lead to form different friendship and enmity. As an example, friendship or enmity between countries can have a political or religious basis. The suggested Hamiltonian is symmetrical between paradigms. Our analyses show that a balanced state can be achieved if just one paradigm prevails in the network and the paradigm shift is possible only by imposing an external field. In this paper, we investigate the influence of the external field on the evolution of the network. We drive the mean-field solutions of the model and verify the accuracy of our analytical solutions by performing Monte-Carlo simulations. We observe that the external field breaks the symmetry of the system. The response of the system to this external field, contingent upon temperature, can be either paramagnetic or ferromagnetic. We observed a hysteresis behavior in the ferromagnetic regime. Once communities are formed based on a certain paradigm, then they resist change. We found that to avoid wasting energy we need to know the level of stochastic behavior in the network. Analogous to magnetic systems, we observe that susceptibility adheres to Curie's law.


Assuntos
Amigos , Magnetismo , Humanos , Imãs , Método de Monte Carlo
3.
Sci Rep ; 13(1): 9416, 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37296130

RESUMO

Although analog-to-digital converters (ADCs) are critical components in mixed-signal integrated circuits (IC), their performance has not been improved significantly over the last decade. To achieve a radical improvement (compact, low power and reliable ADCs), spintronics can be considered as a proper candidate due to its compatibility with CMOS and wide applications in storage, neuromorphic computing, and so on. In this paper, a proof-of-concept of a 3-bit spin-CMOS Flash ADC using in-plane-anisotropy magnetic tunnel junctions (i-MTJs) with spin-orbit torque (SOT) switching mechanism is designed, fabricated and characterized. In this ADC, each MTJ plays the role of a comparator whose threshold is set by the engineering of the heavy metal (HM) width. Such an approach can reduce the ADC footprint. Monte-Carlo simulations based on the experimental measurements show the process variations/mismatch limits the accuracy of the proposed ADC to 2 bits. Moreover, the maximum differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.739 LSB (least significant bit) and 0.7319 LSB, respectively.


Assuntos
Engenharia , Magnetismo , Torque , Método de Monte Carlo
4.
PLoS One ; 17(12): e0279432, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36548368

RESUMO

Removal of excess dideoxy terminators from the sequencing mix after the enzymatic reaction is a key process affecting the dideoxy/Sanger sequencing quality. Ethanol precipitation may be the most popular clean-up method because of its low cost; however, it takes a long centrifugation time and frequently results in low quality sequence data. Commercially available clean-up kits provide high quality sequence data, while they generally have high cost. Here, we describe rapid, effective and low-cost dideoxy terminator clean-up method using a home-made magnetic beads suspension, MagNA, and magnetic separator. We found that MagNA enables rapid and efficient clean-up at ~1/100 of the cost of commercially available kits. The magnetic separator made using low-cost neodymium magnets worked well for the MagNA separation, representing a rapid, efficient and cost-effective dideoxy terminator clean-up system.


Assuntos
Magnetismo , Imãs , Sequência de Bases , Análise de Sequência de DNA/métodos , Fenômenos Magnéticos
5.
Int J Mol Sci ; 23(22)2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36430956

RESUMO

Molecular spintronics devices (MSDs) attempt to harness molecules' quantum state, size, and configurable attributes for application in computer devices-a quest that began more than 70 years ago. In the vast number of theoretical studies and limited experimental attempts, MSDs have been found to be suitable for application in memory devices and futuristic quantum computers. MSDs have recently also exhibited intriguing spin photovoltaic-like phenomena, signaling their potential application in cost-effective and novel solar cell technologies. The molecular spintronics field's major challenge is the lack of mass-fabrication methods producing robust magnetic molecule connections with magnetic electrodes of different anisotropies. Another main challenge is the limitations of conventional theoretical methods for understanding experimental results and designing new devices. Magnetic tunnel junction-based molecular spintronics devices (MTJMSDs) are designed by covalently connecting paramagnetic molecules across an insulating tunneling barrier. The insulating tunneling barrier serves as a mechanical spacer between two ferromagnetic (FM) electrodes of tailorable magnetic anisotropies to allow molecules to undergo many intriguing phenomena. Our experimental studies showed that the paramagnetic molecules could produce strong antiferromagnetic coupling between two FM electrodes, leading to a dramatic large-scale impact on the magnetic electrode itself. Recently, we showed that the Monte Carlo Simulation (MCS) was effective in providing plausible insights into the observation of unusual magnetic domains based on the role of single easy-axis magnetic anisotropy. Here, we experimentally show that the response of a paramagnetic molecule is dramatically different when connected to FM electrodes of different easy-axis anisotropies. Motivated by our experimental studies, here, we report on an MCS study investigating the impact of the simultaneous presence of two easy-axis anisotropies on MTJMSD equilibrium properties. In-plane easy-axis anisotropy produced multiple magnetic phases of opposite spins. The multiple magnetic phases vanished at higher thermal energy, but the MTJMSD still maintained a higher magnetic moment because of anisotropy. The out-of-plane easy-axis anisotropy caused a dominant magnetic phase in the FM electrode rather than multiple magnetic phases. The simultaneous application of equal-magnitude in-plane and out-of-plane easy-axis anisotropies on the same electrode negated the anisotropy effect. Our experimental and MCS study provides insights for designing and understanding new spintronics-based devices.


Assuntos
Fenômenos Magnéticos , Magnetismo , Anisotropia , Eletrodos , Método de Monte Carlo
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2294-2297, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086211

RESUMO

To evaluate the hemocompatibility of individual components of our pediatric left ventricular assist device (LVAD), we proposed a hemocompatibility assessment platform (HAP) with a magnetic levitated bearing system. The HAP consists of a drive system utilizing a brushless direct current (BLDC) motor, passive magnetic bearings (PMB), and an active magnetically levitated bearing (AMB) to reduce the hemolysis generated by HAP itself. In this study, we designed and evaluated the performance of the AMB by measuring radial and axial displacements of the rotor resulting from radially destabilizing forces as well as the performance of the drive system when rotated at increasing speeds to 1,200 rotations per minute (rpm). The results show that, with radial disturbance, the AMB is capable of maintaining axial stability for the BLDC motor system. The AMB can control up to 1,200 rpm without any contact between the rotor and stator. Future work includes geometry optimization for the AMB structure and increase the capability to control stable high-speed rotation for the entire system. Clinical Relevance- This work furthers the development of the magnetic levitated bearing system for a hemocompatibility assessment platform that will be used to enhance and accelerate the development of adult and pediatric LVADs.


Assuntos
Coração Auxiliar , Magnetismo , Criança , Eletricidade , Desenho de Equipamento , Coração Auxiliar/efeitos adversos , Hemólise , Humanos
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2282-2285, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086595

RESUMO

Development of pediatric left ventricular assist devices (LVADs) has lagged behind that of adult LVADs, primarily due to the size and hemocompatibility constraints of pediatric anatomy. To quantify sources of blood trauma during LVAD development, we proposed a hemocompatibility assessment platform (HAP) that can evaluate the hemocompatibility of individual components of LVADs. To eliminate the hemolysis induced by the HAP itself, we incorporated passive magnetic (PM) bearings to suspend the rotor radially and an active magnetic bearing (AMB) to control the axial position. In this study, we numerically evaluated AMB forces of 2 geometries and validated the model by comparing its predictions with experimental results. The magnetic forces generated by the AMB were evaluated by increasing the rotor-stator gap from 0.1 mm to 0.5 mm with a 0.1 mm increment and by varying the coil current from -2 A to 2 A with a 1 A increment. The average error of the numerical models was 8.8% and 7.0% for the two geometries, respectively. Higher errors were found at smaller (<0.2mm) rotor-stator gaps. For both biasing ring sizes, the AMB exhibits high magnetic stiffness from -1 A to 1 A, though it saturates for currents of -2 A and 2 A. This region of high current stiffness was identified as the optimal control region. In future work, this function will be used to tune a control algorithm to modulate current supplied to the AMB, ultimately stabilizing the rotor axially. Clinical Relevance- This work furthers the development of a hemocompatibility assessment platform that will enhance and accelerate the development of adult and pediatric LVADs.


Assuntos
Coração Auxiliar , Magnetismo , Criança , Desenho de Equipamento , Coração Auxiliar/efeitos adversos , Hemólise , Humanos , Fenômenos Magnéticos
8.
Anal Chem ; 94(33): 11492-11499, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35938925

RESUMO

FcγRIIIa-binding affinity is one of the key factors to ensure the efficacy of many antitumor therapeutic antibodies, which should be monitored along with the titer, protein aggregation, and other critical quality attributes. The conventional workflow for the quality assessment of therapeutic antibodies in harvested cell culture fluid (HCCF) is time-consuming and costly nevertheless. In this study, a tractable method was established for rapid quality assessment of a HCCF sample through differentially extracting IgG with different FcγRIIIa affinity levels using FcγRIIIa-immobilized magnetic microspheres, followed by size exclusion chromatography (SEC) to determine the amount and monomer percentage of IgGs in the preceding eluate. FcγRIIIa-immobilized magnetic microspheres with polydopamine (PDA) and hydrophilic dendrimer (PAMAM) coating (denoted as Fe3O4@PDA@PAMAM-FcγRIIIa) were synthesized for the first time as magnetic adsorbents. The PDA cladding endowed the composites with good chemical stability in acidic elution buffer, and the PAMAM dendrimer empowered the composites of high ligand immobilization capacity and hydrophilic surface. The labile FcγRIIIa was immobilized under mild conditions. By directly applying a simple magnetic solid phase extraction procedure to treat HCCF, favored IgG species with high FcγRIIIa affinity would be selectively captured by Fe3O4@PDA@PAMAM-FcγRIIIa composites for subsequent SEC analysis. The monomer peak area value in SEC, which was set as the read-out of the proposed method, correlated directly with the theoretical overall quality of standard-spiked HCCF samples.


Assuntos
Fenômenos Magnéticos , Magnetismo , Técnicas de Cultura de Células , Imunoglobulina G , Microesferas
9.
Neuroimage ; 261: 119498, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35917918

RESUMO

Increased static field inhomogeneities are a burden for human brain MRI at Ultra-High-Field. In particular they cause enhanced Echo-Planar image distortions and signal losses due to magnetic susceptibility gradients at air-tissue interfaces in the subject's head. In the past decade, Multi-Coil Arrays (MCA) have been proposed to shim the field in the brain better than the 2nd or 3rd order Spherical Harmonic (SH) coils usually offered by MRI manufacturers. Here we present a novel MCA, named SCOTCH, optimized for whole brain shimming. Based on a cylindrical structure, it features several layers of small coils whose shape, size and location are found from a principal component analysis of ideal stream functions computed from an internal 100-brain fieldmap database. From an Open-Access external database of 126 brains, our SCOTCH implementation is shown to be equivalent to a partial 7th-order SH system with unlimited power, outperforming all known existing MCA prototypes. This result is further confirmed by a low-cost  30-cm diameter SCOTCH prototype built with 48 coils on 3 layers, and tested on 7 volunteers at 7T with a parallel-transmit RF coil made to be inserted in SCOTCH. Echo-Planar images of the subject brains before and after SCOTCH shimming show large signal recoveries, especially in the prefrontal cortex.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Magnetismo , Ondas de Rádio
10.
Ultrasonics ; 125: 106805, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35853285

RESUMO

T(0,1) guided wave is non-dispersive and has been widely used in the long distance inspection and condition monitoring. Magnetostrictive patch transducer (MPT) is a new type of EMAT with high energy conversion efficiency, which can be used to generate and receive torsional guided waves in pipe samples. In this paper, a permanent magnet broadband torsional guided wave MPT composed of a linear coil EMAT array is proposed. The MPT was experimentally verified to be broadband and the bandwidth is 230.79 kHz when using a 5 mm wide linear coil. The wavelength corresponding to the center frequency of the transducer is about 0.6 times the width of the coil. Base on the design, through-hole defects with diameters of 3-6 mm in the 2-mm-thick aluminum plate were quantified by frequency sweeping detection, and the relative error is less than 7 %. Compared with the single-frequency guided wave signal reflected by through-hole defects, the variation pattern of the quantitative results using frequency sweeping can contribute to a more accurate prediction of the remaining service life of the test specimen.


Assuntos
Imãs , Transdutores , Magnetismo , Ondas Ultrassônicas
11.
PeerJ ; 10: e13002, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35228911

RESUMO

Cerebral blood flow (CBF) monitoring is of great significance for treating and preventing strokes. However, there has not been a fully accepted method targeting continuous assessment in clinical practice. In this work, we built a noninvasive continuous assessment system for cerebral blood flow pulsation (CBFP) that is based on magnetic induction phase shift (MIPS) technology and designed a physical model of the middle cerebral artery (MCA). Physical experiments were carried out through different simulations of CBF states. Four healthy volunteers were enrolled to perform the MIPS and ECG synchronously monitoring trials. Then, the components of MIPS related to the blood supply level and CBFP were investigated by signal analysis in time and frequency domain, wavelet decomposition and band-pass filtering. The results show that the time-domain baseline of MIPS increases with blood supply level. A pulse signal was identified in the spectrum (0.2-2 Hz in 200-2,000 ml/h groups, respectively) of MIPS when the simulated blood flow rate was not zero. The pulsation frequency with different simulated blood flow rates is the same as the squeezing frequency of the feeding pump. Similar to pulse waves, the MIPS signals on four healthy volunteers all had periodic change trends with obvious peaks and valleys. Its frequency is close to that of the ECG signal and there is a certain time delay between them. These results indicate that the CBFP component can effectively be extracted from MIPS, through which different blood supply levels can be distinguished. This method has the potential to become a new solution for non-invasive and comprehensive monitoring of CBFP.


Assuntos
Magnetismo , Artéria Cerebral Média , Humanos , Fenômenos Físicos , Artéria Cerebral Média/diagnóstico por imagem , Circulação Cerebrovascular , Fenômenos Magnéticos
12.
Environ Sci Pollut Res Int ; 29(31): 46813-46829, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35171415

RESUMO

Triclosan (TCS) is widely used in the production of antibacterial products, being often found in wastewater. Therefore, this study developed new materials via soybean hulls (SBHF) and açaí seeds (AÇSF) functionalization with iron oxide nanoparticles to be applied in the TCS adsorption. The characterization confirmed the functionalization of the materials. The adsorption results indicated that the equilibrium of the process occurred after 480 and 960 min for SBHF and AÇSF, respectively. The maximum adsorptive capacity values were 158.35 and 155.09 mg g-1 for SBHF and AÇSF, respectively, at 318 K. The kinetic and isothermal data better fitted to the pseudo-second-order and Langmuir models. Thermodynamics indicated that the processes had an endothermic, spontaneous, and reversible character. The main adsorption mechanisms were H-bond and π-interactions. The pH and ionic strength studies indicated that the adsorption efficiency has not been reduced pronouncedly. The biosorbents reuse was effective for five cycles. In the synthetic mixture, the removal rate was satisfactory (92.53% and 57.02%, respectively for SBHF and AÇSF). These results demonstrate the biosorbents high potential for large-scale application.


Assuntos
Nanopartículas de Magnetita , Triclosan , Poluentes Químicos da Água , Adsorção , Concentração de Íons de Hidrogênio , Cinética , Magnetismo , Nanopartículas de Magnetita/química , Termodinâmica , Poluentes Químicos da Água/análise
13.
Talanta ; 241: 123243, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35121538

RESUMO

Viral diseases are the primary source of death, making a worldwide influence on healthcare, social, and economic development. Thus, diagnosis is the vital approach to the main aim of virus control and elimination. On the other hand, the prompt advancement of nanotechnology in the field of medicine possesses the probability of being beneficial to diagnose infections normally in labs as well as specifically. Nanoparticles are efficiently in use to make novel strategies because of permitting analysis at cellular in addition to the molecular scale. Henceforth, they assist towards pronounced progress concerning molecular analysis at the nanoscale. In recent times, magnetic nanoparticles conjugated through covalent bonds to bioanalytes for instance peptides, antibodies, nucleic acids, plus proteins are established like nanoprobes aimed at molecular recognition. These modified magnetic nanoparticles could offer a simple fast approach for extraction, purification, enrichment/concentration, besides viruses' recognition precisely also specifically. In consideration of the above, herein insight and outlook into the limitations of conventional methods and numerous roles played by magnetic nanoparticles to extract, purify, concentrate, and additionally in developing a diagnostic regime for viral outbreaks to combat viruses especially the ongoing novel coronavirus (COVID-19).


Assuntos
COVID-19 , Vírus , Humanos , Fenômenos Magnéticos , Magnetismo , SARS-CoV-2 , Vírus/genética
14.
Pol Przegl Chir ; 95(4): 1-5, 2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36807097

RESUMO

Introduction Currently, more and more cases of breast cancer are detected in the early stages of advancement. Removal of the minimum required tissue volume ensures that the proper shape of the breast is maintained. On the other hand, it is important to get negative tissue margins. Objective To present your own experience with the use of preoperative breast tumor determination using the Magseed marker. Material and methods On the eve of the procedure, a Magtrace magnetic marker was administered to determine the lymph nodes and, under ultrasound control, a Magseed magnetic marker to the tumor, and the site of the lesion was marked with a skin marker as the operated site. Before the skin incision, the lesion was located using intraoperative ultrasound and the Sentimag probe. After the tumor was excision, the presence of the marker was confirmed in the preparation using the magnetic method and the compatibility of the ultrasound image before and after the procedure. The results of the research group were 23 patients. Radicality of the procedure was achieved in 20 patients (87%). To assess the size of the preparation and tumor, a formula from the work of Angarita et al. on the volume of the ellipsoid was used. It was assessed what part of the excised preparation was a tumor marked using the Magseed marker. Cohorts of 11 patients at the beginning and end of the evaluated group were compared, showing a significant increase in this parameter. Together with the learning curve, you can identify the tumor much more precisely and save healthy breast tissues by improving the aesthetic effect in the breast range. Conclusions The method of localization of non-pallpatory lesions in the mammary gland using the Magseed marker is simple to use, and the high detection rate directly translates into a reduction in the percentage of non-radical treatments in the case of sparing treatment.


Assuntos
Neoplasias da Mama , Glândulas Mamárias Humanas , Humanos , Feminino , Glândulas Mamárias Humanas/patologia , Neoplasias da Mama/cirurgia , Magnetismo , Mastectomia Segmentar , Linfonodos/patologia
15.
PLoS One ; 16(12): e0262028, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34972160

RESUMO

Single-molecule force spectroscopy (SMFS) instruments (e.g., magnetic and optical tweezers) often use video tracking to measure the three-dimensional position of micron-scale beads under an applied force. The force in these experiments is calibrated by comparing the bead trajectory to a thermal motion-based model with the drag coefficient, γ, and trap spring constant, κ, as parameters. Estimating accurate parameters is complicated by systematic biases from spectral distortions, the camera exposure time, parasitic noise, and least-squares fitting methods. However, while robust calibration methods exist that correct for these biases, they are not always used because they can be complex to implement computationally. To address this barrier, we present Tweezepy: a Python package for calibrating forces in SMFS video-tracking experiments. Tweezepy uses maximum likelihood estimation (MLE) to estimate parameters and their uncertainties from a single bead trajectory via the power spectral density (PSD) and Allan variance (AV). It is well-documented, fast, easy to use, and accounts for most common sources of biases in SMFS video-tracking experiments. Here, we provide a comprehensive overview of Tweezepy's calibration scheme, including a review of the theory underlying thermal motion-based parameter estimates, a discussion of the PSD, AV, and MLE, and an explanation of their implementation.


Assuntos
Magnetismo/métodos , Pinças Ópticas , Imagem Individual de Molécula/métodos , Calibragem , Análise de Fourier , Gravitação , Análise dos Mínimos Quadrados , Funções Verossimilhança , Fenômenos Mecânicos , Modelos Estatísticos , Método de Monte Carlo , Movimento (Física) , Distribuição Normal , Polímeros/química , Linguagens de Programação , Software , Torque
16.
Molecules ; 26(19)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34641411

RESUMO

The method of solvothermal by one-step operation has been performed to synthesize of magnetic amine-functionalized sugarcane bagasse biocomposites (SB-MH). The obtained SB-MH contains 62.34% of Fe, 17.8 mmol/g of amine, and a magnetic property of 19.46 emu/g. The biocomposite surface area increased significantly from 1.617 to 25.789 m2/g after amine functionalization. The optimum condition of SB-MH used for Pb(II) ion removal was achieved at pH 5 for 360 min with adsorption capacity of 203.522 mg/g. The pseudo 2nd order was well-fitted to the model of Pb(II) ion adsorption. Meanwhile, other contaminant parameters number of Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), and dye in wastewater were also remarkably reduced by about 74.4%, 88.0%, and 96.7%, respectively. The reusability of SB-MH with 4th repetitions showed only a slight decrease in performance of 5%. Therefore, the proposed magnetic amine-functionalized sugarcane bagasse biocomposites lead to a very potential adsorbent implemented in high scale due to high surface area, easy separation, stable materials and capability to adsorb contaminants from aqueous solution.


Assuntos
Aminas/química , Materiais Biocompatíveis/química , Celulose/química , Magnetismo , Saccharum/química , Águas Residuárias/química , Poluentes Químicos da Água/isolamento & purificação , Concentração de Íons de Hidrogênio , Purificação da Água/métodos
17.
Sensors (Basel) ; 21(19)2021 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-34640915

RESUMO

Traditional fluxgate sensors used in geomagnetic field observations are large, costly, power-consuming and often limited in their use. Although the size of the micro-fluxgate sensors has been significantly reduced, their performance, including indicators such as accuracy and signal-to-noise, does not meet observational requirements. To address these problems, a new race-track type probe is designed based on a magnetic core made of a Co-based amorphous ribbon. The size of this single-component probe is only Φ10 mm × 30 mm. The signal processing circuit is also optimized. The whole size of the sensor integrated with probes and data acquisition module is Φ70 mm × 100 mm. Compared with traditional fluxgate and micro-fluxgate sensors, the designed sensor is compact and provides excellent performance equal to traditional fluxgate sensors with good linearity and RMS noise of less than 0.1 nT. From operational tests, the results are in good agreement with those from a standard fluxgate magnetometer. Being more suitable for modern dense deployment of geomagnetic observations, this small-size fluxgate sensor offers promising research applications at lower costs.


Assuntos
Magnetismo , Processamento de Sinais Assistido por Computador
18.
Nanoscale ; 13(34): 14552-14571, 2021 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-34473175

RESUMO

Iron oxide nanoparticles (IONPs) are well-known contrast agents for MRI for a wide range of sizes and shapes. Their use as theranostic agents requires a better understanding of their magnetic hyperthermia properties and also the design of a biocompatible coating ensuring their stealth and a good biodistribution to allow targeting of specific diseases. Here, biocompatible IONPs of two different shapes (spherical and octopod) were designed and tested in vitro and in vivo to evaluate their abilities as high-end theranostic agents. IONPs featured a dendron coating that was shown to provide anti-fouling properties and a small hydrodynamic size favoring an in vivo circulation of the dendronized IONPs. While dendronized nanospheres of about 22 nm size revealed good combined theranostic properties (r2 = 303 mM s-1, SAR = 395 W gFe-1), octopods with a mean size of 18 nm displayed unprecedented characteristics to simultaneously act as MRI contrast agents and magnetic hyperthermia agents (r2 = 405 mM s-1, SAR = 950 W gFe-1). The extensive structural and magnetic characterization of the two dendronized IONPs reveals clear shape, surface and defect effects explaining their high performance. The octopods seem to induce unusual surface effects evidenced by different characterization techniques while the nanospheres show high internal defects favoring Néel relaxation for magnetic hyperthermia. The study of octopods with different sizes showed that Néel relaxation dominates at sizes below 20 nm while the Brownian one occurs at higher sizes. In vitro experiments demonstrated that the magnetic heating capability of octopods occurs especially at low frequencies. The coupling of a small amount of glucose on dendronized octopods succeeded in internalizing them and showing an effect of MH on tumor growth. All measurements evidenced a particular signature of octopods, which is attributed to higher anisotropy, surface effects and/or magnetic field inhomogeneity induced by tips. This approach aiming at an analysis of the structure-property relationships is important to design efficient theranostic nanoparticles.


Assuntos
Nanopartículas de Magnetita , Medicina de Precisão , Meios de Contraste , Compostos Férricos , Nanopartículas Magnéticas de Óxido de Ferro , Imageamento por Ressonância Magnética , Magnetismo , Nanomedicina Teranóstica , Distribuição Tecidual
19.
J Mol Graph Model ; 109: 108032, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34509093

RESUMO

In this paper, we have applied Monte Carlo method to investigate the magnetic behaviors of the antiferromagnetic/ferromagnetic mixed spin-5/2 and spin-3/2 Ising bilayer system in a time-dependent magnetic field. We have analyzed the magnetization, magnetic susceptibility, internal energy and hysteresis loops of the system in detail. We have clarified how the different physical parameters affect the critical temperature and observed the triple-loop hysteresis behavior.


Assuntos
Campos Magnéticos , Magnetismo , Método de Monte Carlo , Temperatura
20.
Int J Hyperthermia ; 38(1): 846-861, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34074196

RESUMO

Purpose: Bearing partially or fully metallic passive implants represents an exclusion criterion for patients undergoing a magnetic hyperthermia procedure, but there are no specific studies backing this restrictive decision. This work assesses how the secondary magnetic field generated at the surface of two common types of prostheses affects the safety and efficiency of magnetic hyperthermia treatments of localized tumors. The paper also proposes the combination of a multi-criteria decision analysis and a graphical representation of calculated data as an initial screening during the preclinical risk assessment for each patient.Materials and methods: Heating of a hip joint and a dental implant during the treatment of prostate, colorectal and head and neck tumors have been assessed considering different external field conditions and exposure times. The Maxwell equations including the secondary field produced by metallic prostheses have been solved numerically in a discretized computable human model. The heat exchange problem has been solved through a modified version of the Pennes' bioheat equation assuming a temperature dependency of blood perfusion and metabolic heat, i.e. thermorregulation. The degree of risk has been assessed using a risk index with parameters coming from custom graphs plotting the specific absorption rate (SAR) vs temperature increase, and coefficients derived from a multi-criteria decision analysis performed following the MACBETH approach.Results: The comparison of two common biomaterials for passive implants - Ti6Al4V and CoCrMo - shows that both specific absorption rate (SAR) and local temperature increase are found to be higher for the hip prosthesis made by Ti6Al4V despite its lower electrical and thermal conductivity. By tracking the time evolution of temperature upon field application, it has been established that there is a 30 s delay between the time point for which the thermal equilibrium is reached at prostheses and tissues. Likewise, damage may appear in those tissues adjacent to the prostheses at initial stages of treatment, since recommended thermal thresholds are soon surpassed for higher field intensities. However, it has also been found that under some operational conditions the typical safety rule of staying below or attain a maximum temperature increase or SAR value is met.Conclusion: The current exclusion criterion for implant-bearing patients in magnetic hyperthermia should be revised, since it may be too restrictive for a range of the typical field conditions used. Systematic in silico treatment planning using the proposed methodology after a well-focused diagnostic procedure can aid the clinical staff to find the appropriate limits for a safe treatment window.


Assuntos
Calefação , Hipertermia Induzida , Simulação por Computador , Humanos , Hipertermia , Campos Magnéticos , Magnetismo , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA