Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Am Heart Assoc ; 8(16): e013436, 2019 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-31394997

RESUMO

Background Fetal magnetocardiography (fMCG) is a highly effective technique for evaluation of fetuses with life-threatening arrhythmia, but its dissemination has been constrained by the high cost and complexity of Superconducting Quantum Interference Device (SQUID) instrumentation. Optically pumped magnetometers (OPMs) are a promising new technology that can replace SQUIDs for many applications. This study compares the performance of an fMCG system, utilizing OPMs operating in a person-sized magnetic shield, to that of a conventional fMCG system, utilizing SQUID magnetometers operating in a magnetically shielded room. Methods and Results fMCG recordings were made in 24 subjects using the SQUID system with the mother lying supine in a magnetically shielded room and the OPM system with the mother lying prone in a person-sized, cylindrical shield. Signal-to-noise ratios of the OPM and SQUID recordings were not statistically different and were adequate for diagnostic purposes with both technologies. Although the environmental noise was higher using the small open-ended shield, this was offset by the higher signal amplitude achieved with prone positioning, which reduced the distance between the fetus and sensors and improved patient comfort. In several subjects, fMCG provided a differential diagnosis that was more precise and/or definitive than was possible with echocardiography alone. Conclusions The OPM-based system was portable, improved patient comfort, and performed as well as the SQUID-based system at a small fraction of the cost. Electrophysiological assessment of fetal rhythm is now practical and will have a major impact on management of fetuses with long QT syndrome and other life-threatening arrhythmias.


Assuntos
Arritmias Cardíacas/diagnóstico , Magnetocardiografia/instrumentação , Diagnóstico Pré-Natal/instrumentação , Flutter Atrial/diagnóstico , Complexos Atriais Prematuros/diagnóstico , Bloqueio Atrioventricular/diagnóstico , Ecocardiografia , Feminino , Coração Fetal , Humanos , Síndrome do QT Longo/diagnóstico , Magnetocardiografia/métodos , Posicionamento do Paciente , Gravidez , Diagnóstico Pré-Natal/métodos , Decúbito Ventral , Razão Sinal-Ruído , Decúbito Dorsal , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Sinusal/diagnóstico , Taquicardia Ventricular/diagnóstico , Torsades de Pointes/diagnóstico , Complexos Ventriculares Prematuros/diagnóstico
2.
SLAS Technol ; 23(5): 463-469, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29447023

RESUMO

Measurement of the late potentials and His-bundle activity is crucial for many clinical studies using the noncontact and noninvasive magnetocardiography (MCG) technique; these weak signals are extracted by averaging many cardiac cycles aligned using the R-peak of the cardiac cycle identified using an electrocardiography (ECG) lead. ECG is measured simultaneously with MCG using a conventional dual-supply ECG amplifier, which requires either two separate batteries or a single battery with a switching voltage inverter circuit for its proper operation. The ECG circuitry based on two separate batteries requires a relatively large voltage supply (-18 to +18 V). The single-supply (low voltage: 0-9 V) ECG circuitry may be implemented using a switching voltage inverter; however, this mode of operation introduces switching noise in the system. The objective of the present work is to overcome these problems by carefully designing a low-voltage, single-supply ECG system, which can be used simultaneously with the MCG setup without introducing a significant level of additional noise in the MCG measurement system.


Assuntos
Eletrocardiografia/instrumentação , Desenho de Equipamento , Magnetocardiografia/instrumentação , Artefatos
3.
Prenat Diagn ; 37(2): 193-196, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27891637

RESUMO

Fetal magnetocardiography provides the requisite precision for diagnostic measurement of electrophysiological events in the fetal heart. Despite its significant benefits, this technique with current cryogenic based sensors has been limited to few centers, due to high cost of maintenance. In this study, we show that a less expensive non-cryogenic alternative, optically pumped magnetometers, can provide similar electrophysiological and quantitative characteristics when subjected to direct comparison with the current technology. Further research can potentially increase its clinical use for fetal magnetocardiography. © 2016 John Wiley & Sons, Ltd.


Assuntos
Coração Fetal/diagnóstico por imagem , Magnetocardiografia/instrumentação , Magnetocardiografia/métodos , Diagnóstico Pré-Natal , Análise Custo-Benefício , Estudos de Viabilidade , Feminino , Humanos , Magnetocardiografia/economia , Magnetometria/economia , Magnetometria/instrumentação , Magnetometria/métodos , Óptica e Fotônica/instrumentação , Gravidez , Terceiro Trimestre da Gravidez , Diagnóstico Pré-Natal/economia , Diagnóstico Pré-Natal/instrumentação , Diagnóstico Pré-Natal/métodos
4.
Lik Sprava ; (12): 94-105, 2014 Dec.
Artigo em Ucraniano | MEDLINE | ID: mdl-26638476

RESUMO

The article is devoted to clinical--economic analysis of modern diagnostic technology--magnetocardiography by analyzing the "cost-effectiveness". Economic effectiveness of diagnosis of coronary artery disease using magnetocardiography in terms of cost/effectivness is shown. The economicaly optimal sequence of several noninvasive methods for diagnosis of coronary artery disease is defined.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/economia , Análise Custo-Benefício/estatística & dados numéricos , Magnetocardiografia/economia , Modelos Estatísticos , Doença da Artéria Coronariana/fisiopatologia , Ecocardiografia/economia , Ecocardiografia/instrumentação , Teste de Esforço/economia , Teste de Esforço/instrumentação , Humanos , Magnetocardiografia/instrumentação , Fatores de Risco , Tomografia Computadorizada de Emissão/economia , Tomografia Computadorizada de Emissão/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA