Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 558
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Mater Sci Mater Med ; 35(1): 28, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833196

RESUMO

AIM: This study aimed to comprehensively assess the biocompatibility and toxicity profiles of poly(methyl methacrylate) (PMMA) and its monomeric unit, methyl methacrylate (MMA), crucial components in dental materials for interim prosthetic restorations. METHODOLOGY: Molecular docking was employed to predict the binding affinities, energetics, and steric features of MMA and PMMA with selected receptors involved in bone metabolism and tissue development, including RANKL, Fibronectin, BMP9, NOTCH2, and other related receptors. The HADDOCK standalone version was utilized for docking calculations, employing a Lamarckian genetic algorithm to explore the conformational space of ligand-receptor interactions. Furthermore, molecular dynamics (MD) simulations over 100 nanoseconds were conducted using the GROMACS package to evaluate dynamic actions and structural stability. The LigandScout was utilized for pharmacophore modeling, which employs a shape-based screening approach to identify potential ligand binding sites on protein targets. RESULTS: The molecular docking studies elucidated promising interactions between PMMA and MMA with key biomolecular targets relevant to dental applications. MD simulation results provided strong evidence supporting the structural stability of PMMA complexes over time. Pharmacophore modeling highlighted the significance of carbonyl and hydroxyl groups as pharmacophoric features, indicating compounds with favorable biocompatibility profiles. CONCLUSION: This study underscores the potential of PMMA in dental applications, emphasizing its structural stability, molecular interactions, and safety considerations. These findings lay a foundation for future advancements in dental biomaterials, guiding the design and optimization of materials for enhanced biocompatibility. Future directions include experimental validation of computational findings and the development of PMMA-based dental materials with improved biocompatibility and clinical performance.


Assuntos
Materiais Biocompatíveis , Materiais Dentários , Teste de Materiais , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Polimetil Metacrilato , Materiais Biocompatíveis/química , Polimetil Metacrilato/química , Materiais Dentários/química , Humanos , Ligantes , Simulação por Computador , Sítios de Ligação
2.
J Contemp Dent Pract ; 25(3): 241-244, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690697

RESUMO

AIM: The current study was designed to assess the linear dimensional changes and adaptability of two heat-cured denture base resins using various cooling methods. MATERIALS AND METHODS: To prepare a total of 90 acrylic resin samples (45 acrylic resin samples for each material), four rectangular stainless-steel plates measuring 25 × 25 × 10 mm were fabricated. For both groups, the material was put into the mold at the dough stage. Group I - SR Triplex Hot Heat Cure acrylic; group II - DPI Heat Cure acrylic. Both groups used the same curing procedure. One of the following three techniques was used to cool the material (15 samples from each material) once the curing cycle was finished: (A) water bath, (b) quenching, and (C) air. A traveling microscope was used to measure the distance between the markings on the acrylic samples. The data was recorded and statistically analyzed. RESULTS: In SR Triplex Hot heat cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.242 ± 0.05), followed by the air technique (0.168 ± 0.11) and the least was found in the water bath technique (0.146 ± 0.01). In DPI Heat Cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.284 ± 0.09), followed by the air technique (0.172 ± 0.18) and the least was found in the water bath technique (0.158 ± 0.10). There was a statistically significant difference found between these three cooling techniques. On comparison of adaptability, the water bath technique, the marginal gap SR Triplex Hot was 0.012 ± 0.02 and DPI Heat Cure was 0.013 ± 0.02. In the quenching technique, the marginal gap SR Triplex Hot was 0.019 ± 0.04 and DPI Heat Cure was 0.016 ± 0.04. In the air technique, the marginal gap SR Triplex Hot was 0.017 ± 0.01 and DPI Heat Cure was 0.019 ± 0.01. CONCLUSION: The present study concluded that among the different cooling methods, the water bath technique had the least linear dimensional change, followed by the air and quenching techniques. When comparing the materials, DPI Heat Cure acrylic resin showed a greater linear dimensional change than SR Triplex Hot heat cure acrylic resin. CLINICAL SIGNIFICANCE: During polymerization, heat-cured acrylic resins experience dimensional changes. Shrinkage and expansion are dimensional changes that occur in heat-cured acrylic resins and have an impact on the occlusal relationship and denture fit. However, the denture base's material qualities and the different temperature variations it experiences during production may have an impact on this. How to cite this article: Kannaiyan K, Rathod A, Bhushan P, et al. Assessment of Adaptability and Linear Dimensional Changes of Two Heat Cure Denture Base Resin with Different Cooling Techniques: An In Vitro Study. J Contemp Dent Pract 2024;25(3):241-244.


Assuntos
Resinas Acrílicas , Bases de Dentadura , Temperatura Alta , Teste de Materiais , Resinas Acrílicas/química , Técnicas In Vitro , Temperatura Baixa , Materiais Dentários/química
3.
Clin Exp Dent Res ; 10(3): e856, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38818850

RESUMO

OBJECTIVES: This study aimed to compare the flexural strength of monolithic zirconia with different thicknesses and two sintering techniques. MATERIALS AND METHODS: This in vitro, experimental study was conducted on 28 monolithic zirconia discs with 10 mm diameter and 0.5 (n = 14) and 1.2 mm (n = 14) thickness. Each group was divided into two subgroups (n = 7) for fast (60 min) and conventional (120 min) sintering at 1450°C. After sintering, the specimens were thermocycled and their flexural strength was measured by piston-on-3-balls technique in a universal testing machine (0.5 mm/min, 1.2 mm pin diameter). Data were analyzed by the Weibull test, one-way analysis of variance, and Tukey's test (α = .05). RESULTS: The flexural strength of specimens with 1.2 mm thickness was significantly higher than that of specimens with 0.5 mm thickness (p < .05). The flexural strength of 1.2 mm/120-min group was slightly, but not significantly, higher than that of 1.2 mm/60-min group (p > .05). The flexural strength of 0.5 mm/120-min group was slightly, but not significantly, higher than that of 0.5 mm/60-min group (p > .05). CONCLUSION: The increase in thickness of monolithic zirconia increases its flexural strength; however, increasing the sintering time appears to have no significant effect on the flexural strength of monolithic zirconia.


Assuntos
Materiais Dentários , Resistência à Flexão , Teste de Materiais , Zircônio , Zircônio/química , Materiais Dentários/química , Análise do Estresse Dentário , Propriedades de Superfície , Temperatura Alta , Técnicas In Vitro
4.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795258

RESUMO

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese Dentária
5.
J Dent ; 144: 104942, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38494044

RESUMO

OBJECTIVES: This study endeavours to investigate the effect of printing orientation on the trueness of additively manufactured molar zirconia crowns. The areal surface roughness and the characteristics of the marginal regions of the crowns were also considered. METHODS: Twelve molar crowns were manufactured at 0°, 45°, and, 90° printing orientations in a Lithoz and AON zirconia printer, respectively. Twelve milled crowns were used as a comparison. Samples were scanned and analysed in metrology software to determine the trueness of the groups. Regions of interest were defined as the margins, intaglio surface and contact points. Areal surface roughness and print layer thickness were further analysed using a confocal laser scanning microscope. RESULTS: The results indicate that there are clear differences between the investigated desktop (AON) and industrial (Lithoz) 3D printer. The 45° Lithoz group is the only sample group showing no significantly different results in trueness for all regions analysed compared to the milled group. Areal surface roughness analysis indicates that the print layers in the marginal regions are within clinically tolerable limits and surface characteristics. CONCLUSIONS: The printing orientation for zirconia crowns is critical to trueness, and differences are evident between different AM apparatuses. Considerations for design and orientation between different apparatuses should therefore be considered when utilising direct additive manufacturing processes. The areal surface roughness of the marginal regions is within acceptable clinical limits for all manufacturing processes and print orientations considered. CLINICAL SIGNIFICANCE: The materials and apparatuses for additive manufacturing of zirconia crowns are now clinically acceptable from the perspective of the trueness of a final crown for critical functional surfaces and areal surface roughness of the marginal regions.


Assuntos
Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Impressão Tridimensional , Propriedades de Superfície , Zircônio , Zircônio/química , Humanos , Materiais Dentários/química , Microscopia Confocal , Dente Molar , Teste de Materiais , Adaptação Marginal Dentária
6.
J Contemp Dent Pract ; 25(1): 58-61, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514432

RESUMO

AIM: The aim of the current investigation was to evaluate the marginal microleakage of various esthetic restorative materials applied to primary teeth. MATERIALS AND METHODS: A total of 75 noncarious primary molars that were removed for orthodontic intervention and teeth nearing exfoliation were chosen. One millimeter (mm) above the cementoenamel junction, on the buccal surface of the teeth, Class V cavities were prepared. William's graded periodontal probe was used to standardize cavity preparation on all teeth. 3 mm was the cavity's length, 2 mm in width, and 2 mm in depth. The teeth were then divided into three groups (25 samples in each group) according to the type of esthetic restorative material used. Group I: Resin-modified glass ionomer cement, Group II: Ormocer, Group III: Giomer. The samples underwent 500 cycles of thermocycling, with an immersion time of 60 seconds and a well time of 15 seconds, between 5 and 55°C. The samples were submerged in methylene blue dye for 24 hours at room temperature and dried. The samples were then divided into sections and examined with a stereomicroscope. Data was recorded and statistically analyzed. RESULTS: The least marginal microleakage was found in the ormocer group (1.22 ± 0.01) followed by resin-modified glass ionomer cement group (1.31 ± 0.07) and the giomer group (1.78 ± 0.03). There was a highly statistically significant difference found between resin-modified glass ionomer cement group and the ormocer group, resin-modified glass ionomer cement group and giomer group. And no significant difference was found between the ormocer group and the giomer group. CONCLUSION: The present study concluded that there was some amount of microleakage in primary teeth in all restorative materials examined in this in-vitro investigation. However, the marginal sealing ability of ormocer was found highest compared to resin-modified glass ionomer cement and Giomer materials. CLINICAL SIGNIFICANCE: The primary reason dental restorations fail, particularly in Class V cavities, is microleakage since the margins of these restorations are typically found in the dentin or cementum. Assessing microleakage is a crucial step in determining the marginal integrity of restorative materials. Developing methods and resources that reduce the adverse effects caused by the restorative marginal seal failing would benefit from this. How to cite this article: Al Ghwainem A, Alqarni AS. Comparative Assessment of Marginal Micro Leakage of Different Esthetic Restorative Materials Used on Primary Teeth: An In-vitro Study. J Contemp Dent Pract 2024;25(1):58-61.


Assuntos
Resinas Compostas , Infiltração Dentária , Humanos , Cerâmicas Modificadas Organicamente , Restauração Dentária Permanente/efeitos adversos , Restauração Dentária Permanente/métodos , Estética Dentária , Materiais Dentários , Cimentos de Ionômeros de Vidro , Preparo da Cavidade Dentária/métodos , Dente Decíduo , Infiltração Dentária/etiologia
7.
J Dent ; 141: 104792, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38013004

RESUMO

PURPOSE: To evaluate the trueness, precision, time efficiency, and cost of three different workflows for manufacturing single crowns (SCs). METHODS: A plaster model with a prepared tooth (#15) was scanned with an industrial scanner, and an SC was designed in computer-assisted-design (CAD) software. Ten SCs were printed with a hybrid composite (additive chairside) and a stereolithographic (SLA) printer (Dfab®), 10 SCs were milled in lithium disilicate (subtractive chairside) using a chairside milling unit (inLab MC XL®), and 10 SCs were milled in zirconia (lab-based) using a five-axis laboratory machine (DWX-52D®). All SCs were scanned with the same scanner after polymerization/sinterization. Each scan was superimposed to the marginal area of the original CAD file to evaluate trueness: absolute average (ABS AVG), root mean square (RMS), and (90˚-10˚)/2 percentile were calculated for each group. Marginal adaptation and quality of the occlusal and interproximal contact points were also investigated by two prosthodontists on 3D printed and plaster models. Finally, the three workflows' time efficiency and costs were evaluated. RESULTS: Additive chairside and subtractive lab-based SCs had significantly better marginal trueness than subtractive chairside SCs in all three parameters (ABS AVG, p < 0.01; RMS, p < 0.01; [90˚-10˚]/2, p < 0.01). However, the two prosthodontists found no significant differences between the three manufacturing procedures in the quality of the marginal closure (p = 0.186), interproximal (p = 0.319), and occlusal contacts (p = 0.218). Both time efficiency and cost show a trend favoring the chairside additive workflow. CONCLUSIONS: Chairside additive technology seems to represent a valid alternative for manufacturing definitive SCs, given the high marginal trueness, precision, workflow efficiency and low costs. STATEMENT OF CLINICAL RELEVANCE: Additive chairside manufacturing of definitive hybrid composite SCs is now possible and shows high accuracy, time efficiency, and competitive cost.


Assuntos
Coroas , Planejamento de Prótese Dentária , Fluxo de Trabalho , Planejamento de Prótese Dentária/métodos , Materiais Dentários , Desenho Assistido por Computador , Custos e Análise de Custo , Adaptação Marginal Dentária
8.
Clin Oral Investig ; 27(12): 7489-7499, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37971540

RESUMO

OBJECTIVES: The aim was to compare the porosity of different bulk-fill resin-based composites (RBCs) placement techniques to the conventional incremental technique using microcomputed tomography (µ-CT). MATERIAL AND METHODS: Occlusal cavities were prepared on extracted human molars, divided into five groups based on the placement technique (n = 10/group). Techniques examined were Monoblock-two-step (SureFil SDR flow + Ceram.X), Monoblock-two-step (Tetric EvoFlow Bulk-Fill + Tetric EvoCeram Bulk-Fill), Monoblock-one-step (Tetric EvoCeram Bulk-Fill), Monoblock with sonic activation (SonicFill2), and incremental technique (Filtek Z250). µ-CT scanning (SkyScan, Bruker, Belgium) assessed the number, volume of closed pores, and total porosity. Analysis of variance on ranks was used (Student-Newman-Keuls method and Mann-Whitney rank-sum test), to determine the significance of RBC viscosity and the sonication placement technique. The Spearman correlation method assessed the correlation between porosity characteristics (α = 0.05). RESULTS: The SonicFill2 presented a higher number of closed pores than the other groups (p < 0.05). The overall porosity within the restoration seemed greater in this order: Filtek Z250 > SonicFill2 > Tetric EvoFlow Bulk-Fill + Tetric EvoCeram Bulk-Fill > Tetric EvoCeram Bulk-Fill > SureFil SDR Flow + Ceram.X. Sonication was associated with increased number (p = 0.005) and volume (p = 0.036) of closed pores. A strong correlation was observed between the number and volume of closed pores (R2 = 0.549, p < 001). CONCLUSIONS: The monoblock technique with sonic activation showed significantly more internal porosity than the other placement techniques. Sonication during application contributed to the higher number and volume of closed pores than the passive bulk-fill application. CLINICAL RELEVANCE: Using bulk-fill materials enhances efficiency, yet void formation remains an issue, depending on viscosity and active/passive delivery of materials. Clinicians must familiarize themselves with effective placement techniques to reduce void formation and optimizing treatment outcomes.


Assuntos
Resinas Compostas , Materiais Dentários , Humanos , Microtomografia por Raio-X , Porosidade , Teste de Materiais , Viscosidade , Restauração Dentária Permanente/métodos
9.
BMC Oral Health ; 23(1): 948, 2023 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-38036982

RESUMO

BACKGROUND: Attachment material is one of the contributing factors to the degree of wear of the attachment components in mandibular implant-retained overdentures. The purpose of this in vitro study was to compare the wear behavior of 2 different attachment systems of dissimilar materials in mandibular implant-retained overdentures by qualitative and quantitative methods. METHODS: Two attachment systems of different materials were utilized (n = 16); Titach (Dental Evolutions Inc, Beverly Hills, CA, USA) with a titanium-to-titanium interface and Locator R-Tx (Zest Anchors Inc, Escondido, CA, USA) with a titanium-to-nylon interface. One thousand cycles of overdenture insertion and removal simulating 1-year clinical use were performed. All matrices were removed from the overdentures and all patrices were unscrewed from the implants for wear assessment quantitively using a stereomicroscope and qualitatively using a scanning electron microscope. Data were analyzed by using an independent sample t test. RESULTS: After cyclic loading, stereomicroscopic findings showed that the Titach group had statistically significant higher wear value than the Locator R-Tx group (p < 0.001). Moreover, scanning electron microscopy images showed noticeable abrasion in Titach patrix at the area of highest convexity. However, the Locator R-Tx matrix displayed an apparent tear of rubber inserts. CONCLUSIONS: Titach attachment with the titanium-to-titanium interface revealed more wear than Locator R-Tx attachment with the titanium-to-nylon interface. Thus, the type of attachment material influences the degree of wear of the attachment components.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Humanos , Titânio , Nylons , Prótese Dentária Fixada por Implante , Retenção de Dentadura , Materiais Dentários , Mandíbula , Análise do Estresse Dentário
10.
BMC Oral Health ; 23(1): 789, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875872

RESUMO

OBJECTIVES: The aim was to evaluate the color stability of six commercial restorative resin composites after being exposed to commonly consumed beverages. Repolishing impact on the stained composite was also assessed. METHODS: One-hundred and fifty disc specimens (8 mm diameter & 3 mm thickness) were prepared from Filtek™ Universal Restorative, SDR flow+, everX Flow, G-ænial A'CHORD, G-ænial Universal Flo and G-ænial Universal Injectable. To assess the color stability in five various beverages, 25 specimens from each material were randomly distributed into five groups (n = 5), according to the utilized staining solution. Group 1: distilled water, Group 2: coffee, Group 3: red wine, Group 4: energy drink, Group 5: coke. The color changes (∆E) for all materials were measured using spectrophotometer at the baseline, after 84 days of staining and after repolishing. Data was collected and analyzed using ANOVA (α = 0.05). RESULTS: Both material type and staining solution had a significant effect on the color stability of specimens (p < 0.05). Compared to other beverages, the color value of the specimens submerged in coffee and wine showed the most statistically significant (p < 0.05) mean ∆E. SDR flow + in coffee and wine presented the highest ∆E when compared to other tested materials (p < 0.05). After staining of the composites, repolishing was successful in lowering the ∆E value. CONCLUSIONS: All the beverages had an impact on the color stability of the tested resin composites, with coffee and wine demonstrating the most significant effects. The variations in color stability varied depending on the specific material utilized. Dentists should possess awareness regarding the chemical interactions that occur between different beverages and various types of resin composites. Additionally, repolishing serves as an effective technique for eliminating surface discoloration in composite restorations.


Assuntos
Café , Vinho , Humanos , Bebidas , Cor , Resinas Compostas , Materiais Dentários , Teste de Materiais , Espectrofotometria , Propriedades de Superfície
11.
J Contemp Dent Pract ; 24(7): 473-476, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37622625

RESUMO

AIM: The purpose of the current study was to evaluate the erosive impact of various beverages on the esthetic restorative materials utilized in primary teeth. MATERIALS AND METHODS: One hundred and twenty primary molars indicated for serial extraction or over-retention reason with sound buccal surfaces were collected. One millimeter above the cemento-enamel junction, standard Class V cavities were prepared. Following cavity preparation, all teeth were randomly assigned (20 samples per group for each beverage) to one of the three experimental groups based on the type of filling materials: group I: resin-modified glass ionomer cement (GC), group II: nanocomposite resin and group III nanohybrid ormocer-based composite. The samples were kept suspended in various containers containing 250 mL of each orange juice and cola at a temperature of 37°C for three hours per day and rest of day in distilled water. This procedure was repeated for 15 days. Using a 3D optical profilometer, a profilometric reading was recorded for each specimen. RESULTS: The minimum surface roughness was found in nanohybrid ormocer­based composite (1.816 ± 0.16 and 1.302 ± 0.08) followed by resin-modified glass ionomer cement (3.101 ± 0.12 and 2.946 ± 0.09) and nanocomposite resin (5.242 ± 0.20 and 4.488 ± 0.16) after immersed in the cola and orange juice, respectively. And there was a statistically significant difference found between the different esthetic restorative materials in both media. CONCLUSION: On conclusion, the current investigation demonstrates that when exposed to both beverages, the erosive effect was much lesser in nanohybrid ormocer-based composite, followed by resin-modified glass ionomer cement and nanocomposite resin. CLINICAL SIGNIFICANCE: Consuming high-calorie, low pH acidic foods and beverages such as carbonated beverages and fruit juices can lead to erosion, a frequent condition that results in irreparable damage to dental hard tissues and early deterioration of dental restorations.


Assuntos
Bebidas , Materiais Dentários , Estética Dentária , Bebidas/efeitos adversos , Cimentos de Ionômeros de Vidro , Cerâmicas Modificadas Organicamente , Dente Decíduo , Dente Molar , Humanos
12.
J Am Dent Assoc ; 154(8): 705-714.e10, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37500233

RESUMO

BACKGROUND: Advancements in dental materials and changing parental preferences are modifying the frequency of use of restorative materials. This insurance claims analysis examined the trends in the use of amalgam and resin composite in the United States. METHODS: Commercial dental insurance claims were analyzed to compare 505,994 restorations, corresponding with procedure codes for 1-, 2-, and 3-surface amalgam or resin restorations. Paid claims collected nationwide from January 2010 through March 2020 were analyzed. Data for children aged 3 through 12 years were used, resulting in 219,632 unique patient identification numbers. Generalized estimating equation models applied to logistic regression were used. All tests were conducted using a 2-sided 5% significance level. RESULTS: In general, girls were less likely to receive amalgam than boys. A $20,000 increase in median household income was associated with a 16% decrease in the odds of amalgam being placed. Pediatric dentists (performing 15.1% of all restorations) were not as likely as general dentists (18.4%) to use amalgam. Having more surfaces in a restoration was associated with higher probability of amalgam placement. The percentage of amalgam restorations was higher for 2010 (26.9%) than for 2011 through 2020, and this pattern recurred in several of the years analyzed. Generally, patient age at time of amalgam restoration increased over time. CONCLUSION: The use of amalgam is trending down; the sharpest decline was noted in 2014. Pediatric dentists were less likely to use amalgam than general dentists. Girls and patients with higher socioeconomic status were less likely to have amalgam. PRACTICAL IMPLICATIONS: The findings of this study can inform and support clinical decisions and the formation of public policies.


Assuntos
Restauração Dentária Permanente , Seguro , Masculino , Criança , Feminino , Humanos , Restauração Dentária Permanente/métodos , Odontopediatria , Materiais Dentários , Resinas Compostas , Amálgama Dentário
13.
Pediatr Dent ; 45(3): 221-230, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37381125

RESUMO

PURPOSE: To assess the effectiveness of nonpharmacological behavior guidance interventions used for children and youth with special health care needs (CYSHCN) during preventive and dental treatment visits. METHODS: Databases: Ovid MEDLINE, PsycINFO (EBSCOhost), Embase, and Cochrane Library, were searched from 1946 to February 2022, for randomized clinical trials (RCTs) comparing effectiveness of basic and advanced nonpharmacological techniques rendered during a preventive visit (exam, fluoride application, radiographs, and prophylaxis) or a treat- ment visit (simple surgical treatment, sealants, restorative care with or with local anesthesia) with control or other interventions. The primary outcome measures for the studied interventions were reduction in anxiety, fear, pain, and improvement in cooperative behavior. Eight authors determined the included Randomized Controlled Trials (RCTs), performed data extraction, and assessed the risk of bias (ROB). Standardized Mean Difference calculation and assignment of quality of evidence by Grading of Recommendations Assessment, Development and Evaluation approach were done. RESULTS: Eleven articles qualified for analysis from 219 screened articles. Included studies evaluate the effectiveness of in office strategies such as modeling, audio-visual distraction, sensory adapted dental environment, and picture exchange communication system. The certainty of evidence ranged from Very low to Low and the magnitude of effect varied from trivial to large change in the desired outcomes. CONCLUSIONS: Most basic non-pharmacological behavior guidance techniques showed some trivial to small reduction in self-reported anxiety and/ or improvement in behavior, with audiovisual distraction, Sensory Adapted Dental Environment, and Picture Exchange Communication System showing large reduction in anxiety based on some rating scales. Systematic Review Registration Number: PROSPERO: CRD42022314723.


Assuntos
Anestesia Local , Terapia Comportamental , Adolescente , Criança , Humanos , Materiais Dentários , Fluoretos , Atenção à Saúde
14.
Dent Mater ; 39(7): 669-676, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37230861

RESUMO

OBJECTIVES: The aim of this study was to evaluate the mechanical properties and cost efficiency of direct ink writing (DIW) printing of two different zirconia inks compared to casting and subtractive manufacturing. METHODS: Zirconia disks were manufactured by DIW printing and the casting process and divided into six subgroups (n = 20) according to sintering temperatures (1350 °C, 1450 °C and 1550 °C) and two different ink compositions (Ink 1, Ink 2). A CAD/CAM-milled high strength zirconia (3Y-TZP) was added as reference group. The biaxial flexural strength (BFS) was measured using the piston-on-three-balls test. X-ray-diffraction (XRD) was used for microstructural analysis. The cost efficiency was compared for DIW printing and subtractive manufacturing by calculation of the manufacturing costs of one dental crown. RESULTS: Using XRD, monoclinic and tetragonal phases were detected for Ink 1, for all other groups no monoclinic phase was detected. The CAD/CAM-milled ceramic showed a significantly higher BFS than all other groups. The BFS of Ink 2 was significantly higher than the BFS of Ink 1. At a sintering temperature of 1550 °C the mean BFS of the printed Ink 2 was 822 ± 174 MPa. The BFS of the cast materials did not show a significantly higher BFS than the corresponding printed group for any tested parameter-set. The manufacturing costs of DIW printed crowns are lower than the manufacturing costs of CAD/CAM-milled crowns. CONCLUSION: DIW has a high potential to replace subtractive processes for dental applications, as it shows promising mechanical properties for appropriate ink compositions and facilitates a highly cost effective production.


Assuntos
Cerâmica , Tinta , Teste de Materiais , Propriedades de Superfície , Cerâmica/química , Zircônio/química , Desenho Assistido por Computador , Impressão Tridimensional , Materiais Dentários/química
15.
J Prosthet Dent ; 129(1): 150-159, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34330531

RESUMO

STATEMENT OF PROBLEM: In computer-aided design and computer-aided manufacturing (CAD-CAM) dentistry, the CAD of the prosthesis represents the clinical prerequisite design to restore the treated tooth. However, how closely the CAM prosthesis shape matches the CAD, particularly in relation to different materials, is unclear. PURPOSE: The purpose of this in vitro study was to evaluate onlays designed and manufactured with the same CAD-CAM system but manufactured with different materials. MATERIAL AND METHODS: A single standard tessellation language (STL) model was used to produce 6 composite resin onlays, 6 leucite glass-ceramic onlays, and 6 lithium disilicate glass-ceramic onlays. The onlays were digitized by using an X-ray microtomographic protocol with a metrological calibration. The CAD model was then compared with the scans of the different onlays. An analysis by region of interest was then carried out to assess the accuracy and reliability of the dimensional accuracy. RESULTS: The composite resin and the lithium disilicate glass-ceramic had the best dimensional accuracy. The leucite glass-ceramic exhibited a lack of trueness linked to consistent overmilling. The composite resin had less peripheral chipping than the glass-ceramics. CONCLUSIONS: The composite resin and the lithium disilicate glass-ceramic material exhibited satisfactory dimensional accuracy. Milling the glass-ceramic before crystallization considerably improved dimensional accuracy.


Assuntos
Cerâmica , Porcelana Dentária , Reprodutibilidade dos Testes , Teste de Materiais , Cerâmica/química , Restaurações Intracoronárias , Resinas Compostas/química , Desenho Assistido por Computador , Materiais Dentários
16.
Caries Res ; 57(1): 12-20, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36549276

RESUMO

The aim of this study was to compare the performance of two visual criteria used for the detection of caries around restorations in permanent teeth. In this delayed-type cross-sectional study, the study sample was randomly allocated to one of two visual criteria for the assessment of restorations as follows: (a) International Dental Federation (FDI) criteria, considers marginal staining, marginal adaptation, and caries recurrence and (b) Caries Associated with Restorations or Sealants (CARS) criteria, defined by the International Caries Classification and Management System. A calibrated examiner assessed the restorations using two reference standards as follows: (i) for restorations requiring operative interventions (repair/replacement), the restoration was partially or totally removed and the presence or absence of carious tissue was assessed; and (ii) for restorations requiring nonoperative intervention, follow-up for a period of 1 year was recommended to allow identification of the presence of new lesions not detected at baseline. The sensitivity, specificity, area under receiver operating characteristic curve (Az), and accuracy of the criteria were assessed. The study included 305 restorations. The FDI marginal staining parameter had the lowest Az value (Az = 0.501), while similar sensitivity was observed between the CARS (62.0%), FDI presence of caries (65.0%), and FDI marginal adaptation (74.0%) parameters. CARS exhibited the highest specificity (88.3%) and accuracy (85.6%). The CARS criteria exhibited better specificity and accuracy in detecting caries around restorations, followed by the FDI criteria for caries recurrence and marginal adaptation. Considering marginal staining or combining multiple marginal features to assess secondary caries resulted in an increased risk of false-positive outcomes and overtreatment.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Resinas Compostas , Estudos Transversais , Cárie Dentária/diagnóstico , Cárie Dentária/terapia , Cárie Dentária/etiologia , Suscetibilidade à Cárie Dentária , Materiais Dentários , Restauração Dentária Permanente/métodos , Dentição Permanente
17.
Dent Mater ; 39(1): 13-24, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36428112

RESUMO

OBJECTIVES: Different types of direct-placement dental materials are used for the restoration of structure, function and aesthetics of teeth. The aim of this research investigation is to determine, through a comparative cradle-to-gate life cycle assessment, the environmental impacts of three direct-placement dental restorative materials (DRMs) and their associated packaging. METHODS: Three direct-placement dental materials; dental amalgam, resin-based composite (RBC) and glass polyalkenoate cements (GIC) are assessed using primary data from a manufacturer (SDI Limited, Australia). The functional unit consisted of 'one dental restoration' of each restorative system under investigation: 1.14 g of dental amalgam; 0.25 g of RBC (plus the adhesive = 0.10 g); and 0.54 g of GIC. The system boundary per restoration included the raw materials and their associated packaging materials for each DRM together with the processing steps for both the materials and packaging. The environmental impacts were assessed using an Egalitarian approach under the ReCiPe method using Umberto software and the Ecoinvent database. Nine different impact categories were used to compare the environmental performance of these materials. RESULTS: Dental amalgam had the highest impact across most of the categories, but RBC had the highest Global Warming Potential. The highest sources of the environmental impacts for each restorative material were: Amalgam, derived from material use; RBC, derived from energy use in processing material and packaging material; GIC, derived from material and energy use for packaging. SIGNIFICANCE: Less intensive energy sources or more sustainable packaging materials can potentially reduce the impacts associated with RBC and GIC thus making them suitable alternatives to dental amalgam.


Assuntos
Amálgama Dentário , Restauração Dentária Permanente , Animais , Restauração Dentária Permanente/métodos , Materiais Dentários , Cimentos de Ionômeros de Vidro/química , Estágios do Ciclo de Vida , Resinas Compostas
18.
J Contemp Dent Pract ; 24(12): 1016-1025, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38317401

RESUMO

AIMS: The purpose of this systematic review was to evaluate the cost-effectiveness and acceptance of children and their parents of the Hall technique (HT) for dental rehabilitation in pediatric dentistry. BACKGROUND: The approach of the HT is that of minimally invasive treatment of the dental element and is used exclusively on primary molars. Various studies in the literature point to HT as a restorative option well accepted by children and parents and quite predictable, with low retreatment rates and good cost-effectiveness for the management of primary molars with carious lesions. However, no systematic review in the literature has approached randomized clinical trials on these topics to produce a high level of evidence and help establish clinical HT protocols. REVIEW RESULTS: Eight articles were selected for the systematic review. The HT was more cost-effective than procedures using other restorative materials. Regarding acceptance, in terms of esthetics, high percentages of satisfaction were reported for parents and children, with a divergence between studies in the comparison of esthetic preference with atraumatic restorative treatment. However, when considering crown cementation pain, comfort, anxiety, preference, and satisfaction, the HT was generally better evaluated when compared to other restorative materials. CONCLUSION: The HT is an excellent restorative option when considering cost-effectiveness and acceptance and is recommended for use in daily clinical practice. CLINICAL SIGNIFICANCE: Results indicate that HT is superior to other restorative materials regarding its acceptance by children and parents in terms of pain, comfort, anxiety, and crown preference and satisfaction. There were also high percentages of satisfaction with esthetics. Hall technique may initially appear expensive for dentists, but its effectiveness over time and the lesser need for consultations and reinventions ensure better cost-benefit than other restorative materials. How to cite this article: Valentim FB, Moreira KMS, Carneiro VC, et al. Cost-effectiveness and Acceptance in Children and Parents of the Hall Technique: Systematic Review of Clinical Trials. J Contemp Dent Pract 2023;24(12):1016-1025.


Assuntos
Tratamento Dentário Restaurador sem Trauma , Cárie Dentária , Criança , Humanos , Análise Custo-Benefício , Dente Decíduo , Restauração Dentária Permanente/métodos , Estética Dentária , Cárie Dentária/terapia , Materiais Dentários , Dor , Pais
19.
J Dent ; 127: 104350, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36341980

RESUMO

OBJECTIVES: To develop a risk of bias tool for pre-clinical dental materials research studies that aims to support reporting of future investigations and improve assessment in systematic reviews. METHODS: A four-stage process following EQUATOR network recommendations was followed, which included project launch, literature review, Delphi process and the tool finalization. With the support of the European Federation of Conservative Dentistry (EFCD) and the Dental Materials Group of the International Association for Dental Research (DMG-IADR), a total of 26 expert stakeholders were included in the development and Delphi vote of the initial proposal. The proposal was built using data gathered from the literature review stage. During this stage, recent systematic reviews featuring dental materials research, and risk of bias tools found in the literature were comprehensively scanned for bias sources. The experts thus reached a consensus for the items, domains and judgement related to the tool, allowing a detailed guide for each item and corresponding signalling questions. RESULTS: The tool features nine items in total, spread between 4 domains, pertaining to the following types of bias: bias related to planning and allocation (D1), specimen preparation (D2), outcome assessment (D3) and data treatment and outcome reporting (D4). RoBDEMAT, as presented, features signalling questions and a guide that can be used for RoB judgement. Its use as a checklist is preferred over a final summary score. CONCLUSION: RoBDEMAT is the first risk of bias tool for pre-clinical dental materials research, supported and developed by a broad group of expert stakeholders in the field, validating its future use. CLINICAL SIGNIFICANCE: This new tool will contribute the study field by improving the scientific quality and rigour of dental materials research studies and their systematic reviews. Such studies are the foundation and support of future clinical research and evidence-based decisions.


Assuntos
Lista de Checagem , Publicações , Revisões Sistemáticas como Assunto , Viés , Materiais Dentários
20.
Niger J Clin Pract ; 25(4): 516-523, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35439913

RESUMO

Background: One of the most specific effects of high-density dental restorative materials on head & neck cancer radiotherapy is generating variations on isodose distributions. These variations might have an impact on the accuracy and effectiveness of the radiation treatment. The aim of this study is investigating the possible dosimetric effect of six different restorative materials on isodose distributions in head & neck radiotherapy planning process. Materials and Methods: A special phantom was developed and twenty-one caries-free human third molars (a control group + six different restorative materials) were used for the measurements. After acquiring the computed tomography (CT) images, seven treatment plans were created. Hounsfield Unit (HU) numbers, horizontal line dose profile (HLDP) and vertical line dose profiles (VLDPs) were compared with the control group. Results: The amalgam sample deformed the HU numbers in CT images. The median HU value for the S4 material was considerably different than the other samples. The median values were quite close for the remaining samples. For the amalgam sample, the mean of the calculated median isodose values for HLDP and VLDP at 3.5 cm away from the isocenter line were lower than the mean of the control group 4.03% and 6.94%, respectively (for HLDP with tooth numbers of 36 and 38 P = 0.025 and P < 0.001, respectively; for VLDP P < 0.001). In C-S1 comparison results, the statistically significant differences were found for the measurement point at 1 cm away from the isocenter (P = 0.037, P = 0.002, and P = 0.018 for the tooth numbers 36, 37, and 38, respectively). In C-S2 and C-S6 comparisons, there was a statistically significant difference for tooth number 36 (P = 0.035 and P = 0.003, respectively). Conclusions: The findings of the present study showed that amalgam should not be used in head & neck cancer patients who are planned to have radiation therapy. A high viscosity glass ionomer cement (GIC) and a ceramic reinforced GIC sample can be used instead of amalgam to minimize the distorting effect on isodose distributions.


Assuntos
Neoplasias de Cabeça e Pescoço , Materiais Dentários , Cimentos de Ionômeros de Vidro/uso terapêutico , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA