Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Acta Biomater ; 58: 181-195, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28536061

RESUMO

To successfully develop biomedical applications for magnetic nanoparticles, it is imperative that these nanoreagents maintain their magnetic properties in vivo and that their by-products are safely metabolized. When placed in biological milieu or internalized into cells, nanoparticle aggregation degree can increase which could affect magnetic properties and metabolization. To evaluate these aggregation effects, we synthesized citric acid-coated iron oxide nanoparticles whose magnetic susceptibility can be modified by aggregation in agar dilutions and dextran-layered counterparts that maintain their magnetic properties unchanged. Macrophage models were used for in vitro uptake and metabolization studies, as these cells control iron homeostasis in the organism. Electron microscopy and magnetic susceptibility studies revealed a cellular mechanism of nanoparticle degradation, in which a small fraction of the particles is rapidly degraded while the remaining ones maintain their size. Both nanoparticle types produced similar iron metabolic profiles but these profiles differed in each macrophage model. Thus, nanoparticles induced iron responses that depended on macrophage programming. In vivo studies showed that nanoparticles susceptible to changes in magnetic properties through aggregation effects had different behavior in lungs, liver and spleen. Liver ferritin levels increased in these animals showing that nanoparticles are degraded and their by-products incorporated into normal metabolic routes. These data show that nanoparticle iron metabolization depends on cell type and highlight the necessity to assess nanoparticle aggregation in complex biological systems to develop effective in vivo biomedical applications. STATEMENT OF SIGNIFICANCE: Magnetic iron oxide nanoparticles have great potential for biomedical applications. It is however imperative that these nanoreagents preserve their magnetic properties once inoculated, and that their degradation products can be eliminated. When placed in a biological milieu nanoparticles can aggregate and this can affect their magnetic properties and their degradation. In this work, we showed that iron oxide nanoparticles trigger the iron metabolism in macrophages, the main cell type involved in iron homeostasis in the organism. We also show that aggregation can affect nanoparticle magnetic properties when inoculated in animal models. This work confirms iron oxide nanoparticle biocompatibility and highlights the necessity to assess in vivo nanoparticle aggregation to successfully develop biomedical applications.


Assuntos
Ácido Cítrico , Materiais Revestidos Biocompatíveis , Ferritinas/sangue , Ferro/sangue , Macrófagos/metabolismo , Nanopartículas de Magnetita , Animais , Linhagem Celular , Ácido Cítrico/química , Ácido Cítrico/farmacocinética , Ácido Cítrico/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacocinética , Materiais Revestidos Biocompatíveis/farmacologia , Feminino , Humanos , Nanopartículas de Magnetita/química , Nanopartículas de Magnetita/uso terapêutico , Camundongos , Células THP-1
2.
Acta Biomater ; 36: 310-22, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26965394

RESUMO

UNLABELLED: The aim of this study was to evaluate the osseointegration of titanium implants (Ti-6Al-4V, noted here TA6V) and poly(etheretherketone) PEEK implants induced by a BMP-2-delivering surface coating made of polyelectrolyte multilayer films. The in vitro bioactivity of the polyelectrolyte film-coated implants was assessed using the alkaline phosphatase assay. BMP-2-coated TA6V and PEEK implants with a total dose of 9.3µg of BMP-2 were inserted into the femoral condyles of New Zealand white rabbits and compared to uncoated implants. Rabbits were sacrificed 4 and 8weeks after implantation. Histomorphometric analyses on TA6V and PEEK implants and microcomputed tomography on PEEK implants revealed that the bone-to-implant contact and bone area around the implants were significantly lower for the BMP-2-coated implants than for the bare implants. This was confirmed by scanning electron microscopy imaging. This difference was more pronounced at 4weeks in comparison to the 8-week time point. However, bone growth inside the hexagonal upper hollow cavity of the screws was higher in the case of the BMP-2 coated implants. Overall, this study shows that a high dose of BMP-2 leads to localized and temporary bone impairment, and that the dose of BMP-2 delivered at the surface of an implant needs to be carefully optimized. STATEMENT OF SIGNIFICANCE: The presentation of growth factors from material surfaces currently presents significant challenges in academia, clinics and industry. Applying osteoinductive factors to different types of implants, made of metals or polymers, may improve bone repair in difficult situations. Here, we show the effects of an osteoinductive coating made of polyelectrolyte multilayer films on two widely used materials, titanium TA6V alloys and PEEK implants, which were implanted in the rabbit femoral condyle. We show that a too high dose of BMP-2 delivered from the screw surface has a negative short-term effect on bone regeneration in close vicinity of the screw surface. In contrast, bone formation was increased at early times in the empty spaces around the screw. These results highlight the need for future dose-dependence studies on bone formation in response to osteoinductive coatings.


Assuntos
Proteína Morfogenética Óssea 2 , Parafusos Ósseos , Materiais Revestidos Biocompatíveis , Fêmur , Cetonas , Teste de Materiais , Polietilenoglicóis , Titânio , Ligas , Animais , Benzofenonas , Proteína Morfogenética Óssea 2/química , Proteína Morfogenética Óssea 2/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacocinética , Cetonas/química , Cetonas/farmacologia , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Polímeros , Coelhos , Titânio/química , Titânio/farmacologia
3.
J Mater Sci Mater Med ; 26(10): 241, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26411437

RESUMO

Activated protein C (APC), an endogenous protein, inhibits inflammation and thrombosis and interrupts the coagulation cascade. Here, we investigated the effect of human recombinant APC on the development of neointimal hyperplasia in porcine coronary arteries. Yukon Choice bare metal stents were coated with 2.6 µg APC/mm(2). Under general anesthesia, APC-coated and bare stents were implanted in the left anterior descending and circumflex coronary arteries of 10 domestic pigs. During the 4-week follow-up, animals were treated with dual antiplatelet therapy and neointimal hyperplasia was evaluated via histology. Scanning electron microscopy indicated successful but unequal coating of stents with APC; nearly complete drug release occurred within 4 h. Enzyme-linked immunosorbent assay revealed that intracoronary stent implantation rapidly increased the levels of monocyte chemoattractant protein-1, an effect that was inhibited by APC release from the coated stent. Fibrin deposition and adventitial inflammation were significantly decreased 1 month after implanting APC-coated stents versus bare stents, paralleled by significantly smaller neointimal area (0.98 ± 0.92 vs. 1.44 ± 0.91 mm(2), P = 0.028), higher lumen area (3.47 ± 0.94 vs. 3.06 ± 0.91 mm(2), P = 0.046), and lower stenosis area (22.2 ± 21.2% vs. 32.1 ± 20.1%, P = 0.034). Endothelialization was complete with APC-coated but not bare (90%) stents. P-selectin immunostaining revealed significantly fewer activated endothelial cells in the neointima in the APC group (4.6 ± 1.9 vs. 11.6 ± 4.1%, P < 0.001). Thus, short exposure of coronary arteries to APC reduced inflammatory responses, neointimal proliferation, and in-stent restenosis, offering a promising therapy to improve clinical outcomes of coronary stenting. However, coating stents with APC for prolonged, controlled drug release remains technically challenging.


Assuntos
Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Proteína C/administração & dosagem , Animais , Materiais Revestidos Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/farmacocinética , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/patologia , Stents Farmacológicos/economia , Humanos , Masculino , Teste de Materiais , Modelos Animais , Neointima/diagnóstico por imagem , Neointima/patologia , Neointima/prevenção & controle , Proteína C/farmacocinética , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/farmacocinética , Sus scrofa
4.
Eur J Pharm Biopharm ; 64(2): 185-92, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16797948

RESUMO

In this study, metformin hydrochloride (MH) sustained-release pellets were successfully prepared by centrifugal granulation. Seed cores preparation, drug layering, talc modification and coating of polymeric suspensions were carried out in a centrifugal granulator. Talc modification was performed before coating in order to overcome the high water solubility of metformin. The influence of surface modification by talc, the effects of Eudragit types and ratios, as well as the correlation between in vitro release and in vivo absorption were investigated in detail. Experimental results indicated that talc modification made a decisive contribution to controlling the drug release by avoiding drug dumping. Three dissolution media: 0.1 M HCl, distilled water and pH 6.8 phosphate buffer were employed to determine the in vitro release behaviors of the above metformin hydrochloride pellets. The relative bioavailability of the sustained-release pellets was studied in 12 healthy volunteers after oral administration in a fast state using a commercially available immediate release tablet (Glucophage) as a reference. Following coating with a blend of Eudragit L30D-55 and Eudragit NE30D (1:20), at 7% or 10% coating level, respectively (referred to as F-2, F-3), the pellets acquired perfect sustained-release properties and good relative bioavailability. The Cmax, Tmax and relative bioavailability for F-2 and F-3 coated pellets were 1.21 microg/ml, 6 h, 97.6% and 1.65 microg/ml, 8 h, 165%, respectively. Combined use of two Eudragit polymers with different features as coating materials produced the desired results. Restricted delivery of metformin hydrochloride to the small intestine from differently coated pellets resulted in increased relative bioavailability and a sustained release effect. The adoption of several different pH dissolution media established a better relationship between the in vitro release and in vivo absorption of the sustained-release pellets.


Assuntos
Preparações de Ação Retardada/farmacocinética , Metformina/farmacocinética , Tecnologia Farmacêutica/métodos , Administração Oral , Adulto , Área Sob a Curva , Disponibilidade Biológica , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacocinética , Estudos Cross-Over , Preparações de Ação Retardada/química , Meia-Vida , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/química , Hipoglicemiantes/farmacocinética , Mucosa Intestinal/metabolismo , Masculino , Metformina/administração & dosagem , Metformina/sangue , Metacrilatos/química , Polímeros/química , Solubilidade , Comprimidos , Talco/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA