Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
PLoS One ; 19(5): e0303289, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722891

RESUMO

Malaria and Human Immunodeficiency Virus infections are among the top 10 causes of death in low income countries. Furthermore, many medicines used in these treatment areas are substandard, which contributes to the high death rate. Using a monitoring system to identify substandard and falsified medicines, the study aims to evaluate the quality of antimalarial and antiretroviral medicines in Sahel countries, assessing site conditions, compliance of medicines with pharmacopoeia tests, formulation equivalence with a reference medicine, and the influence of climate on quality attributes. Ultra Performance Liquid Chromatography methods for eight active pharmaceutical ingredients were validated following the International Conference for Harmonization guideline for its detection and quantification. Quality control consists of visual inspections to detect any misinformation or imperfections and pharmacopeial testing to determine the quality of pharmaceutical products. Medicines which complied with uniformity dosage units and dissolution tests were stored under accelerated conditions for 6 months. Artemether/Lumefantrine and Lopinavir/Ritonavir formulations failed uniformity dosage units and disintegration tests respectively, detecting a total of 28.6% substandard medicines. After 6 months stored under accelerated conditions (40 °C // 75% relative humidity) simulating climatic conditions in Sahel countries, some medicines failed pharmacopeia tests. It demonstrated the influence of these two factors in their quality attributes. This study emphasizes the need of certified quality control laboratories as well as the need for regulatory systems to maintain standards in pharmaceutical manufacturing and distribution in these countries, especially when medicines are transported to rural areas where these climatic conditions are harsher.


Assuntos
Antimaláricos , Controle de Qualidade , Antimaláricos/análise , Antimaláricos/normas , Humanos , Antirretrovirais/análise , Saúde Pública , Ritonavir/análise , Ritonavir/uso terapêutico , Administração Oral , Medicamentos Fora do Padrão/análise , Infecções por HIV/tratamento farmacológico , Malária/tratamento farmacológico , Lopinavir/análise , Lopinavir/uso terapêutico
2.
PLoS Negl Trop Dis ; 15(9): e0009539, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34591842

RESUMO

Substandard and falsified (SF) antimalarials have devastating consequences including increased morbidity, mortality and economic losses. Portable medicine quality screening devices are increasingly available, but whether their use for the detection of SF antimalarials is cost-effective is not known. We evaluated the cost-effectiveness of introducing such devices in post-market surveillance in pharmacies in Laos, conservatively focusing on their outcome in detecting SF artemisinin-based combination therapies (ACTs). We simulated the deployment of six portable screening devices: two handheld near-infrared [MicroPHAZIR RX, NIR-S-G1], two handheld Raman [Progeny, TruScan RM]; one portable mid-infrared [4500a FTIR] spectrometers, and single-use disposable paper analytical devices [PADs]. We considered two scenarios with high and low levels of SF ACTs. Different sampling strategies in which medicine inspectors would test 1, 2, or 3 sample(s) of each brand of ACT were evaluated. Costs of inspection including device procurement, inspector time, reagents, reference testing, and replacement with genuine ACTs were estimated. Outcomes were measured as disability adjusted life years (DALYs) and incremental cost-effectiveness ratios were estimated for each device compared with a baseline of visual inspections alone. In the scenario with high levels of SF ACTs, all devices were cost-effective with a 1-sample strategy. In the scenario of low levels of SF ACTs, only four devices (MicroPHAZIR RX, 4500a FTIR, NIR-S-G1, and PADs) were cost-effective with a 1-sample strategy. In the multi-way comparative analysis, in both scenarios the NIR-S-G1 testing 2 samples was the most cost-effective option. Routine inspection of ACT quality using portable screening devices is likely to be cost-effective in the Laos context. This work should encourage policy-makers or regulators to further investigate investment in portable screening devices to detect SF medicines and reduce their associated undesired health and economic burdens.


Assuntos
Antimaláricos/química , Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Medicamentos Falsificados/análise , Medicamentos Fora do Padrão/análise , Antimaláricos/economia , Técnicas de Química Analítica/economia , Serviços Comunitários de Farmácia , Análise Custo-Benefício , Medicamentos Falsificados/economia , Humanos , Laos/epidemiologia , Malária/tratamento farmacológico , Malária/economia , Malária/epidemiologia , Vigilância de Produtos Comercializados , Medicamentos Fora do Padrão/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA