Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 434
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Radiologie (Heidelb) ; 64(6): 503-514, 2024 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-38780657

RESUMO

The aim of this article is to provide an overview on the most frequently applied image-guided, percutaneous, local ablative techniques for treatment of primary and secondary liver tumors. The technical procedures of microwave ablation (MWA) and radiofrequency ablation (RFA) are presented. The pre-interventional diagnostics, indications and feasibility are also discussed, taking the current national guidelines into consideration. Finally, treatment outcomes and recommendations on post-interventional imaging following local tumor ablation are presented.


Assuntos
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Ablação por Radiofrequência/métodos , Cirurgia Assistida por Computador/métodos , Técnicas de Ablação/métodos , Cuidados Pré-Operatórios/métodos , Resultado do Tratamento
2.
Environ Sci Pollut Res Int ; 31(20): 30039-30058, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38594565

RESUMO

Heedless disposal of oil-based fly ash contributes to the contamination of the air, water, and soil. Acid leaching of industrial solid wastes is recognized as a versatile, cost-effective, and environmentally friendly solid waste treatment approach. The present study investigated the viability of conventional leaching (CL) and microwave-assisted leaching (MAL) of predominant heavy metals from Mazut-burnt fly ash. For this purpose, the practicality of four organic acids with various specifications (ascorbic, gluconic, citric, and oxalic acids) on the dissolution efficiency of fly ash components was examined. Utilization of oxalic acid led to achieving full V recovery, complete Fe removal, and Ni enrichment in the residue in both CL and MAL setups. The Ni content of the sample was enriched from 6% in the calcinated sample to 23.7% in the oxalic acid leaching residue. Using citric acid resulted in the co-extraction of V, Ni, and Fe with nearly 70% V, 50% Ni, and 89% Fe dissolved in CL. The dissolution efficiencies were slightly lower in MAL. Oxalic acid was selected as the most promising organic acid reagent for fly ash treatment, so its CL kinetics was studied and defined by the shrinking particle model. The model showed that the controlling steps in the leaching of V differ over time, changing from a chemical reaction before 60 min to fluid film diffusion or mixing afterward. The kinetic study proved MAL as an effective technique in overcoming the leaching kinetic barriers. A life cycle assessment study was conducted to determine the environmental impacts of the proposed process. Accordingly, the MAL using oxalic acid was the most environmentally friendly process among the studied ones, and the utilization of microwaves leads to the reduction of the leaching processes' environmental impacts by decreasing the processing time.


Assuntos
Cinza de Carvão , Micro-Ondas , Cinza de Carvão/química , Cinética , Metais Pesados/química , Ácido Oxálico/química
3.
Free Radic Res ; 58(3): 194-216, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38563404

RESUMO

Microwave (MW) radiations are widely used in communications, radar and medical treatment and thus human exposure to MW radiations have increased tremendously, raising health concerns as MW has been implicated in induction of oxidative stress condition in our body. Few metallic nanoparticles (NPs) have been shown to mimic the activity of antioxidant enzymes and hence can be applied for the modulation of adverse effects caused by MW. Present study aimed to assess the biocompatibility of Bovine serum albumin (BSA) conjugated manganese dioxide nanoparticles (MNP*) and to counteract the impact of MW on the haematological system of male Wistar rats. Experiments were conducted in two sets. Set I involved biodistribution and antioxidant activity evaluation of MNP* at different doses. Results showed a dose-dependent increase in antioxidant potential and significant biodistribution in the liver, spleen, kidney, and testis, with no organ damage, indicating its biocompatibility. Experiment set II constituted the study of separate and combined effects of MW and MNP* on haematological parameters, oxidative status, and genotoxic study in the blood of rats. MW exposure significantly altered red blood cell count, hemoglobin, packed cell volume percentage, monocyte percentage, aspartate aminotransferase, Alanine aminotransferase and uric acid. MW also induced significant DNA damage in the blood. A significant increase in lipid peroxidation and a decrease in antioxidant enzyme superoxide dismutase was also observed in MW exposed group. However, these alterations were reduced significantly when MNP* was administered. Thus, MNP* showed biocompatibility and modulatory effects against MW-induced alterations in the haematological system of rats.


Assuntos
Compostos de Manganês , Micro-Ondas , Nanopartículas , Óxidos , Ratos Wistar , Soroalbumina Bovina , Animais , Masculino , Compostos de Manganês/química , Ratos , Soroalbumina Bovina/química , Óxidos/química , Nanopartículas/química , Estresse Oxidativo/efeitos dos fármacos , Bovinos , Antioxidantes/farmacologia , Nanopartículas Metálicas/química
4.
Am Surg ; 90(6): 1497-1500, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38557117

RESUMO

INTRODUCTION: Collaboration between the health care industry and surgeons is critical in modern medicine. Conflict of interest (COI) has the risk of introducing bias into research studies. We investigated the accuracy of self-disclosed COI for studies that researched the use of microwave ablation for liver metastasis. METHODS: A literature search identified studies that investigated the use of microwave ablation for liver cancer between 2016 and 2022. We utilized the Open Payments Database to query individual authors' financial contributions from the industry. The accuracy of the disclosure statement and financial contribution for each study and author was calculated. We compared the amount of financial contribution authors received based on the accuracy of their COI statement. RESULTS: Twenty-five studies of interest were identified. The mean number of authors was 8.24. A disclosure statement was present in 52% of studies. Of those, 28% had an incongruent disclosure statement. 9/25 (36%) of studies had a conflict of interest based on financial payments provided by industry. Overall, authors received an average of $440,483.41 (SD $1,889,375.34). We did not find a difference in the financial contribution's value based on the disclosure statement's accuracy (P = .55). CONCLUSIONS: Over a quarter of studies in our review of microwave ablation literature had discrepancies in the reporting of conflicts of interest, highlighting the need for improved reporting of potential conflicts of interest to protect the integrity of clinical research. Compared to other fields of surgery, we found a lower rate of undisclosed COI, suggesting that the scope of cancer-directed surgery may be more resistant to industry influence.


Assuntos
Conflito de Interesses , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/secundário , Micro-Ondas/uso terapêutico , Revelação/ética , Técnicas de Ablação/ética , Técnicas de Ablação/economia
5.
Sensors (Basel) ; 24(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38544238

RESUMO

The development of new medical-monitoring applications requires precise modeling of effects on the human body as well as the simulation and the emulation of realistic scenarios and conditions. The first aim of this paper is to develop realistic and adjustable 3D human-body emulation platforms that could be used for evaluating emerging microwave-based medical monitoring/sensing applications such as the detection of brain tumors, strokes, and breast cancers, as well as for capsule endoscopy studies. New phantom recipes are developed for microwave ranges for phantom molds with realistic shapes. The second aim is to validate the feasibility and reliability of using the phantoms for practical scenarios with electromagnetic simulations using tissue-layer models and biomedical antennas. The third aim is to investigate the impact of the water temperature in the phantom-cooking phase on the dielectric properties of the stabilized phantom. The evaluations show that the dielectric properties of the developed phantoms correspond closely to those of real human tissue. The error in dielectric properties varies between 0.5-8%. In the practical-scenario simulations, the differences obtained with phantoms-based simulations in S21 parameters are 0.1-13 dB. However, the differences are smaller in the frequency ranges used for medical applications.


Assuntos
Neoplasias da Mama , Micro-Ondas , Humanos , Feminino , Reprodutibilidade dos Testes , Imagens de Fantasmas , Simulação por Computador
6.
Phytochem Anal ; 35(4): 903-922, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38403936

RESUMO

INTRODUCTION: The safety and quality of many medicinally important herbs are compromised since farmers and small organizations are involved in the cultivation, aggregation, and primary processing of these herbs. Such organizations often lack adequate quality control facilities. To improve the safety and quality of herbal products, simple, rapid, and affordable quality control systems are required. OBJECTIVES: The aim of this study was to assess the suitability of microwave oven-drying for moisture content (MC) determination and sample preparation of herbs in small organizations. METHODS: Microwave oven-drying (720 W) and convective oven-drying at 105°C for MC determination were compared. The effects of three different drying methods (microwave oven-drying, low-temperature convective drying, and freeze-drying) on in vitro antioxidant and polyphenol oxidase (PPO) activity were determined, similarity analysis was conducted using HPLC signature spectra, and validation was performed with LC-MS focusing on one herb. RESULTS: Microwave oven-drying at 720 W significantly reduced the drying time (from hours to minutes), whereas the spatial variation of temperature in convective ovens set at 105°C can cause about 10% underestimation of MC. Microwave oven-drying showed similar macro-properties like freeze-drying and higher extractability (10%-20%) and in vitro antioxidant capacity (33%-66%) and lower PPO activity compared to low-temperature convective drying. HPLC signature spectra revealed strong similarity of soluble components between freeze-dried and microwave oven-dried herbs. LC-MS analysis demonstrated more common compounds between freeze-dried and microwave oven-dried Centella asiatica extracts, whereas convective tray-dried samples had fewer compounds common with samples obtained by freeze-drying or microwave oven-drying. CONCLUSIONS: Microwave oven-drying is rapid (tens of min) and shows small batch-to-batch variation compared to oven-drying at 105°C. The in vitro antioxidant assays and signature spectra can be used for assessing the source and purity or quality of a specific herb variety.


Assuntos
Antioxidantes , Dessecação , Liofilização , Micro-Ondas , Plantas Medicinais , Controle de Qualidade , Plantas Medicinais/química , Antioxidantes/análise , Antioxidantes/química , Dessecação/métodos , Liofilização/métodos , Cromatografia Líquida de Alta Pressão/métodos , Catecol Oxidase/análise
7.
Sci Rep ; 14(1): 4557, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402352

RESUMO

To analyze the correlation between dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) permeability parameters and serum vascular endothelial growth factor (VEGF) levels in a rabbit VX2 liver cancer model with insufficient microwave ablation (MWA), to observe the dynamic changes in residual tumor angiogenesis in the short term after MWA, and to assess the effectiveness of donafenib as adjuvant therapy. Forty rabbits with VX2 liver tumors were randomly divided into three groups: an insufficient MWA group (n = 15), a combined treatment group (n = 15) and a control group (n = 10). The dynamic changes in VEGF expression after MWA and the effectiveness of donafenib as adjuvant therapy were evaluated by DCE-MRI and serum VEGF levels before surgery and 1, 3, 7, and 14 days after surgery. The correlation between the volume translate constant (Ktrans) of DCE-MRI parameters and serum VEGF levels fluctuated after ablation, but the coefficient was always positive (all p < 0.001). Repeated-measures ANOVA revealed significant changes in the serum VEGF concentration (F = 40.905, p < 0.001; partial η2 = 0.689), Ktrans (F = 13.388, p < 0.001; partial η2 = 0.420), and tumor diameter in each group (F = 34.065, p < 0.001; partial η2 = 0.648) at all five time points. Pairwise comparisons showed that the serum VEGF level, Ktrans value and tumor diameter in the insufficient MWA group and combined treatment group were significantly lower at 1 d than in the control group, but these values gradually increased over time (all p < 0.05). Ktrans and tumor diameter were significantly greater in the insufficient MWA group than in the control group at 14 days (all p < 0.05). The serum VEGF concentration, Ktrans, and tumor diameter were significantly lower in the combined treatment group than in the other two groups at 3, 7, and 14 days (all p < 0.05). Ktrans is positively correlated with the serum VEGF concentration. Ktrans and the serum VEGF concentration changed significantly after treatment with insufficient ablation or in combination with donafenib, and Ktrans may change faster. Insufficient MWA promotes the progression of residual tumors. Adjuvant treatment with donafenib is effective.


Assuntos
Neoplasias Hepáticas , Piridinas , Fator A de Crescimento do Endotélio Vascular , Animais , Coelhos , Neoplasia Residual/diagnóstico por imagem , Micro-Ondas , Angiogênese , Imageamento por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/patologia , Meios de Contraste
8.
Int J Hyperthermia ; 41(1): 2313492, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38369302

RESUMO

BACKGROUND: Despite the theoretical advantages of treating metastatic bone disease with microwave ablation (MWA), there are few reports characterizing microwave absorption and bioheat transfer in bone. This report describes a computational modeling-based approach to simulate directional microwave ablation (dMWA) in spine, supported by ex vivo and pilot in vivo experiments in porcine vertebral bodies. MATERIALS AND METHODS: A 3D computational model of microwave ablation within porcine vertebral bodies was developed. Ex vivo porcine vertebra experiments using a dMWA applicator measured temperatures approximately 10.1 mm radially from the applicator in the direction of MW radiation (T1) and approximately 2.4 mm in the contra-lateral direction (T2). Histologic assessment of ablated ex vivo tissue was conducted and experimental results compared to simulations. Pilot in vivo experiments in porcine vertebral bodies assessed ablation zones histologically and with CT and MRI. RESULTS: Experimental T1 and T2 temperatures were within 3-7% and 11-33% of simulated temperature values. Visible ablation zones, as indicated by grayed tissue, were smaller than those typical in other soft tissues. Posthumous MRI images of in vivo ablations showed hyperintensity. In vivo experiments illustrated the technical feasibility of creating directional microwave ablation zones in porcine vertebral body. CONCLUSION: Computational models and experimental studies illustrate the feasibility of controlled dMWA in bone tissue.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Técnicas de Ablação/métodos , Micro-Ondas/uso terapêutico , Simulação por Computador , Coluna Vertebral/cirurgia , Fígado/cirurgia , Ablação por Cateter/métodos
9.
Environ Int ; 184: 108439, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38309194

RESUMO

Microwaves have the advantage of penetrating vegetation and exhibit sensitivity to properties such as vegetation water content (VWC); yet, their potential utility in the fire domain is infrequently investigated. This study elucidates the different impacts of the microwave VWC index EDVI on fire radiative energy (FRE) across various biome types and the significant predictive power for high-severity fires (defined based on FRE) in mainland Southeast Asia. While EDVI exhibits lower predictive power for high severe fires compared to the commonly used fire weather indices (e.g., FWI), an enhancement is observed when these predictors are used in combination. Either by employing EDVI or fire weather indices, the predictability of fires is found to be highest over forests and lowest over croplands. Factors such as increasing human influence and fuel limitation in croplands are likely reducing the roles of VWC and weather on fires, contributing to the lower prediction skill of EDVI and fire weather. These results indicate the usefulness of microwave VWC index in fire studies. Although fire weather presents more considerable impacts on fires, the microwave VWC index seem to still provide some complementary information in fire danger assessment.


Assuntos
Micro-Ondas , Tempo (Meteorologia) , Humanos , Ecossistema , Florestas , Água , Sudeste Asiático
10.
J Vasc Interv Radiol ; 35(4): 523-532.e1, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38215818

RESUMO

PURPOSE: To evaluate the prognostic accuracy of intraprocedural and 4-8-week (current standard) post-microwave ablation zone (AZ) and margin assessments for prediction of local tumor progression (LTP) using 3-dimensional (3D) software. MATERIALS AND METHODS: Data regarding 100 colorectal liver metastases (CLMs) in 75 patients were collected from 2 prospective fluorodeoxyglucose positron emission tomography (PET)/computed tomography (CT)-guided microwave ablation (MWA) trials. The target CLMs and theoretical 5- and 10-mm margins were segmented and registered intraprocedurally and at 4-8 weeks after MWA contrast-enhanced CT (or magnetic resonance [MR] imaging) using the same methodology and 3D software. Tumor and 5- and 10-mm minimal margin (MM) volumes not covered by the AZ were defined as volumes of insufficient coverage (VICs). The intraprocedural and 4-8-week post-MWA VICs were compared as predictors of LTP using receiver operating characteristic curve analysis. RESULTS: The median follow-up time was 19.6 months (interquartile range, 7.97-36.5 months). VICs for 5- and 10-mm MMs were predictive of LTP at both time assessments. The highest accuracy for the prediction of LTP was documented with the intra-ablation 5-mm VIC (area under the curve [AUC], 0.78; 95% confidence interval, 0.66-0.89). LTP for a VIC of 6-10-mm margin category was 11.4% compared with 4.3% for >10-mm margin category (P < .001). CONCLUSIONS: A 3D 5-mm MM is a critical endpoint of thermal ablation, whereas optimal local tumor control is noted with a 10-mm MM. Higher AUCs for prediction of LTP were achieved for intraprocedural evaluation than for the 4-8-week postablation 3D evaluation of the AZ.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Humanos , Resultado do Tratamento , Estudos Prospectivos , Micro-Ondas/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/secundário , Estudos Retrospectivos
11.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38271728

RESUMO

Objective. This study aims to develop and assess a tumor contraction model, enhancing the precision of ablative margin (AM) evaluation after microwave ablation (MWA) treatment for hepatocellular carcinomas (HCCs).Approach. We utilize a probabilistic method called the coherent point drift algorithm to align pre-and post-ablation MRI images. Subsequently, a nonlinear regression method quantifies local tumor contraction induced by MWA, utilizing data from 47 HCC with viable ablated tumors in post-ablation MRI. After automatic non-rigid registration, correction for tumor contraction involves contracting the 3D contour of the warped tumor towards its center in all orientations.Main results. We evaluate the performance of our proposed method on 30 HCC patients who underwent MWA. The Dice similarity coefficient between the post-ablation liver and the warped pre-ablation livers is found to be 0.95 ± 0.01, with a mean corresponding distance between the corresponding landmarks measured at 3.25 ± 0.62 mm. Additionally, we conduct a comparative analysis of clinical outcomes assessed through MRI over a 3 month follow-up period, noting that the AM, as evaluated by our proposed method, accurately detects residual tumor after MWA.Significance. Our proposed method showcases a high level of accuracy in MRI liver registration and AM assessment following ablation treatment. It introduces a potentially approach for predicting incomplete ablations and gauging treatment success.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
12.
Br J Radiol ; 96(1152): 20230383, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37750857

RESUMO

OBJECTIVE: To retrospectively compare and evaluate ablation zone volume and its reduction from baseline to 1 month follow-up post-percutaneous microwave ablation (MWA) between healthy and cirrhotic liver parenchyma. METHODS: Institutional database research identified 84 patients (118 hepatic tumors) who underwent percutaneous MWA with the same system. Caudal-right lobe ratio was applied to distinguish cirrhotic (n = 51) and healthy (n = 67) group; ITK-SNAP software was used to quantify ablation zone volume. Long (LAD) and short 1 (SAD-1) and 2 (SAD-2) axis, tumor size diameter (mm) and volume (cm³) of the ablation zones were evaluated for each treated lesion in both groups at baseline (immediately post-ablation) and at 1 month follow-up. RESULTS: There was no significant difference comparing ablation zone volumes at baseline (healthy group: mean ablation volume 14.84 cm³ vs cirrhotic group: mean ablation volume 17.85 cm³, p = 0.31) and 1 month post-ablation (healthy group: mean ablation volume 9.15 cm³ vs cirrhotic group: mean ablation volume 11.58 cm³, p = 0.24). When both "healthy" and "cirrhotic" liver group were evaluated independently, there was a significant difference of ablation volumes reduction (p-value < 0.001) from baseline to 1 month follow-up. When both groups were compared based on reduction (35.12-38.34%) there was no significant difference in ablation zone volumes (p-value = 0.77). CONCLUSION: Percutaneous MWA results in ablation zones of a comparable volume in both healthy and cirrhotic liver parenchyma. Both cirrhotic and healthy liver parenchyma experience a similar significant reduction of ablation zone volume at 1 month post-therapy. ADVANCES IN KNOWLEDGE STATEMENT: This study evaluates and compares the volume of the ablation zone after MWA between healthy and cirrhotic liver parenchyma from baseline to 1 month follow-up and attempts to identify potential differences. It is the first study to demonstrate significant shrinkage of ablation volumes in healthy livers as compared to cirrhotic livers after 4 weeks of follow-up. The results of this study can help us understand the effect of MWA when applied in different backgrounds of liver parenchyma, which could lead to different treatment planning.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Humanos , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Cirrose Hepática/complicações , Cirrose Hepática/cirurgia , Ablação por Cateter/métodos
13.
Food Chem ; 429: 136916, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37481982

RESUMO

This work presents the first report of the application of microwave-induced combustion in disposable vessels (MIC-DV) as a simple and fast sample preparation step for fluoride determination by ion-selective electrode (ISE) in leguminous seeds and oilseeds samples. Several experimental conditions of MIC-DV were evaluated, such as sample mass, absorbing solution, volume of combustion igniter, purging time with oxygen, and the use of successive combustion cycles. The accuracy of MIC-DV/ISE method was evaluated by comparing the results obtained by microwave-induced combustion and determination by ion chromatography, with agreements ranged from 94 to 106%. The method allowed to achieve relatively low limits of quantification (8.3 to 16 µg g-1) comparing to AOAC method (40 µg g-1), besides the use of small amounts of reagents, less handling of digests, making the method greener and with portable features comparing to other methods.


Assuntos
Fabaceae , Flúor , Eletrodos Seletivos de Íons , Sementes , Micro-Ondas
14.
Int J Biol Macromol ; 242(Pt 2): 124841, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37182628

RESUMO

Depending on its physicochemical properties and antibacterial activities, chitosan can have a wide range of applications in food, pharmaceutical, medicine, cosmetics, agriculture, and aquaculture. In this experimental study, chitosan was extracted from shrimp waste through conventional extraction, microwave-assisted extraction, and conventional extraction under microwave process conditions. The effects of the heating source on the physicochemical properties and antibacterial activity were investigated. The results showed that the heating process parameters affected the physicochemical properties considerably. The conventional procedure yielded high molecular weight chitosan with a 12.7 % yield, while the microwave extraction procedure yielded a porous medium molecular weight chitosan at 11.8 %. The conventional extraction under microwave process conditions led to medium molecular weight chitosan with the lowest yield (10.8 %) and crystallinity index (79 %). Antibacterial assessment findings revealed that the chitosan extracted using the conventional method had the best antibacterial activity in the agar disk diffusion assay against Listeria monocytogenes (9.48 mm), Escherichia coli. (8.79 mm), and Salmonella Typhimurium (8.57 mm). While the chitosan obtained by microwave-assisted extraction possessed the highest activity against E. coli. (8.37 mm), and Staphylococcus aureus (8.05 mm), with comparable antibacterial activity against S. Typhimurium (7.34 mm) and L. monocytogenes (6.52 mm). Moreover, the minimal inhibitory concentration and minimal bactericidal concentration assays demonstrated that among the chitosan samples investigated, the conventionally-extracted chitosan, followed by the chitosan extracted by microwave, had the best antibacterial activity against the target bacteria.


Assuntos
Quitosana , Animais , Quitosana/farmacologia , Quitosana/química , Micro-Ondas , Escherichia coli , Crustáceos , Antibacterianos/farmacologia , Antibacterianos/química , Alimentos Marinhos
15.
Food Chem ; 420: 136097, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37060672

RESUMO

The evaluation of the migration of ionic silver and nanoparticulated silver (AgNPs) from antimicrobial plastic packaging to food is crucial to ensure its safety. Migration assays were performed on reusable silver-containing polypropylene (PP) food containers and a silicone baby bottle, using food simulants, under conventional or microwave heating and repeated use. The PP containers released significant amounts of silver, increasing with temperature, contact time, acidity and lower crystallinity. Silver migration in the silicone bottle was much lower. Risk assessment of released silver was done considering European authorities safety recommendations, with some containers far exceeding these levels. No significant AgNPs release was detected in the simulants by single particle-ICPMS. Silver-containing microplastics and silicone microparticles were detected by SEM in the food simulants after the migration assays. Consumers may be continuously exposed to the harmful effects of ionic silver and microplastics, which can potentially lead to health issues.


Assuntos
Nanopartículas Metálicas , Plásticos , Embalagem de Alimentos , Microplásticos , Prata/análise , Calefação , Micro-Ondas , Nanopartículas Metálicas/análise , Antibacterianos , Polipropilenos , Medição de Risco , Contaminação de Alimentos/análise
16.
Int J Hyperthermia ; 40(1): 2187743, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36944369

RESUMO

INTRODUCTION: The aim of this study was to assess the safety of bronchoscopic microwave ablation (MWA) of peripheral lung parenchyma using the NEUWAVE™ FLEX Microwave Ablation System, and robotic-assisted bronchoscopy (RAB) using the MONARCH™ Platform in a swine model. METHODS: Computed tomography (CT)-guided RAB MWA was performed in the peripheral lung parenchyma of 17 Yorkshire swine (40-50 kg) and procedural adverse events (AEs) documented. The acute group (day 0, n = 5) received 4 MWAs at 100 W for 1, 3, 5, and 10 min in 4 different lung lobes. Subacute and chronic groups (days 3 and 30, n = 6 each) received one MWA (100 W, 10 min) per animal. RESULTS: The study was completed without major procedural complications. No postprocedural AEs including death, pneumothorax, bronchopleural fistula, hemothorax, or pleural effusions were observed. No gross or histological findings suggestive of thromboembolism were found in any organ. One 3-Day and one 30-Day swine exhibited coughing that required no medication (minor AEs), and one 30-Day animal required antibiotic medication (major AE) for a suspected lower respiratory tract infection that subsided after two weeks. CT-based volumetric estimates of ablation zones in the acute group increased in an ablation time-dependent (1-10 min) manner, whereas macroscopy-based estimates showed an increasing trend in ablation zone size. CONCLUSION: The NEUWAVE FLEX and MONARCH devices were safely used to perform single or multiple RAB MWAs. The preclinical procedural safety profile of RAB MWA supports clinical research of both devices to investigate efficacy in select patients with oligometastatic disease or primary NSCLC.


Assuntos
Ablação por Cateter , Neoplasias Pulmonares , Procedimentos Cirúrgicos Robóticos , Animais , Suínos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Broncoscopia , Micro-Ondas/uso terapêutico , Segurança de Equipamentos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Pulmão/patologia , Neoplasias Pulmonares/cirurgia , Ablação por Cateter/métodos
17.
Lasers Surg Med ; 55(4): 372-377, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36950892

RESUMO

BACKGROUND: Microwave therapy is used to treat axillary hyperhidrosis and osmidrosis. Even while a "danger zone" has been identified and reports of potential complications from nerve injury have been made, there has been little real-world discussion regarding whether there is any pretreatment evaluation key factor that may lower the risk. Furthermore, the efficacy of a single treatment and the safety of high-energy therapies have not been well investigated. OBJECTIVE: The aim of this study is to demonstrate the key aspects of pre-therapeutic assessment, efficacy, and suitability of a single treatment, as well as the safety of high-energy treatments. METHODS: Fifteen patients with axillary hyperhidrosis (AH) and axillary osmidrosis (AO) between ages of 20 and 50 had pretherapeutic ultrasonography and clinical assessments performed followed by a single-pass microwave treatment using the miraDry system at energy level 5. The severity of AH and AO was evaluated using the Hyperhidrosis Disease Severity Scale and Odor-10 scale, respectively, at baseline, 1 month, 3 months, and 1 year after treatment. Adverse reactions were recorded at each point of evaluation. RESULTS: Out of 30 treatment areas, 14 have a danger zone. Female gender, a small mid-upper arm circumference, and a low body mass index (BMI) are all associated risk factors. The average Hyperhidrosis Disease Severity Scale score decreased from 3.1 ± 0.7 to 1.3 ± 0.5 (p < 0.001), while the odor-10 score declined from 7.1 ± 1.6 to 3.0 ± 1.6 (p < 0.001), indicating a significant improvement in AH and AO. Most of the unfavorable treatment effects disappeared within the first month. LIMITATIONS: This study has no objective quantitative measurement of axillary odor severity and sweat assessment. CONCLUSION: Female patients, those with a smaller mid-upper arm circumference, and those with a low BMI should be treated with extra caution, and the tumescent anesthetic dose may be increased based on safety. A high-energy microwave treatment procedure performed in a single session is a safe and effective therapeutic option with good recovery.


Assuntos
Hiperidrose , Micro-Ondas , Humanos , Feminino , Resultado do Tratamento , Micro-Ondas/uso terapêutico , Hiperidrose/terapia , Axila , Índice de Gravidade de Doença
18.
J Comput Assist Tomogr ; 47(1): 31-37, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36668979

RESUMO

OBJECTIVE: This study aimed to explore the feasibility and predictive value for local tumor progression (LTP) of the computed tomography (CT)-CT image fusion method versus side-by-side method to assess ablative margin (AM) in hepatocellular carcinoma ≥3 cm in diameter. MATERIALS AND METHODS: We selected patients with hepatocellular carcinoma ≥3 cm in diameter who underwent microwave ablation and had complete tumor ablation. We used the CT-CT image fusion method and side-by-side method to assess AM separately and divided the lesions into 3 groups: group I, minimum ablative margin (min-AM) <0 mm (the ablation zone did not fully cover the tumor); group II, 0 mm ≤ min-AM <5 mm; and group III, min-AM ≥5 mm. RESULTS: A total of 71 patients involving 71 lesions were included. The κ coefficient for the agreement between the CT-CT image fusion method and the side-by-side method in assessing min-AM was 0.14 (P = 0.028). Cumulative LTP rate was significantly different between groups by min-AM from the CT-CT image fusion method (P < 0.05) but not by min-AM from the side-by-side method (P = 0.807). Seventeen of the 20 LTP lesions were located at min-AM on fused CT images, with consistency rate of 85%. CONCLUSIONS: Compared with the side-by-side method, the CT-CT image fusion method is more accurate in assessing the AM of eccentrically ablated lesions and shows better predictive value for LTP. The min-AM based on CT-CT image fusion assessment is an important influencing factor for LTP.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Estudos Retrospectivos
19.
Sensors (Basel) ; 23(1)2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36617074

RESUMO

This paper examines the effect of finger fat pad thickness on the accuracy performance of complementary split-ring resonator (CSRR)-based microwave sensors for non-invasive blood glucose level detection. For this purpose, a simplified four-layer Cole-Cole model along with a CSRR-based microwave sensor have been comprehensively analyzed and validated through experimentation. Computed scattering parameter (S-parameter) responses to different fat layer thicknesses are employed to verify the concordance of the studied model with the measurement results. In this respect, a figure of merit (FM) based on the normalized squared difference is introduced to assess the accuracy of the considered Cole-Cole model. We have demonstrated that the analyzed model agrees closely with the experimental validation. In fact, the maximum error difference for all five fingertips does not exceed 1.73 dB over the entire frequency range of interest, from 1 GHz to 4 GHz.


Assuntos
Glicemia , Micro-Ondas , Tecido Adiposo
20.
Prep Biochem Biotechnol ; 53(5): 565-571, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36047960

RESUMO

Astaxanthin is one of the most attractive carotenoid in the cosmetic, food, pharmaceutical, and aquaculture industries due to its strong bioactive properties. Among the various sources, several algae species are considered as rich sources of astaxanthin. Downstream processing of algae involves the majority of the total processing costs. Thus, elimination of high energy involved steps is imperative to achieve cost-effective scale in industry. This study aimed to determine operation conditions for astaxanthin extraction from wet Haematococcus pluvialis using microwave-assisted extraction. The isolated astaxanthin extract was evaluated for cytotoxicity on human lung cancer cells. The microwave-assisted extraction process at 75 °C under the power of 700 Watt for 7 min gave the highest astaxanthin yield (12.24 ± 0.54 mg astaxanthin/g wet cell weight). Based on MTT cell viability and Hoechst 33342 nuclear staining assays on A549 lung cancer cells, astaxanthin inhibited cell growth in dose- and time-dependent manners, where IC50 value was determined as 111.8 ± 14.8 µg/mL and apoptotic bodies were observed along with positive control group at 72 hr. These results showed that the treatment with astaxanthin extracted from wet H. pluvialis by microwave-assisted extraction exhibited anti-cancer activity on lung cancer cells indicating a newly potential to be utilized in industry.


Assuntos
Neoplasias Pulmonares , Micro-Ondas , Humanos , Desenvolvimento Sustentável , Extratos Vegetais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA