Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Nature ; 587(7832): 157-161, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33087927

RESUMO

Single-particle electron cryo-microscopy (cryo-EM) is a powerful method for solving the three-dimensional structures of biological macromolecules. The technological development of transmission electron microscopes, detectors and automated procedures in combination with user-friendly image processing software and ever-increasing computational power have made cryo-EM a successful and expanding technology over the past decade1. At resolutions better than 4 Å, atomic model building starts to become possible, but the direct visualization of true atomic positions in protein structure determination requires much higher (better than 1.5 Å) resolution, which so far has not been attained by cryo-EM. The direct visualization of atom positions is essential for understanding the mechanisms of protein-catalysed chemical reactions, and for studying how drugs bind to and interfere with the function of proteins2. Here we report a 1.25 Å-resolution structure of apoferritin obtained by cryo-EM with a newly developed electron microscope that provides, to our knowledge, unprecedented structural detail. Our apoferritin structure has almost twice the 3D information content of the current world record reconstruction (at 1.54 Å resolution3). We can visualize individual atoms in a protein, see density for hydrogen atoms and image single-atom chemical modifications. Beyond the nominal improvement in resolution, we also achieve a substantial improvement in the quality of the cryo-EM density map, which is highly relevant for using cryo-EM in structure-based drug design.


Assuntos
Apoferritinas/química , Apoferritinas/ultraestrutura , Microscopia Crioeletrônica/instrumentação , Microscopia Crioeletrônica/normas , Hidrogênio/química , Microscopia Crioeletrônica/métodos , Desenho de Fármacos , Humanos , Modelos Moleculares , Controle de Qualidade
2.
Acta Crystallogr D Struct Biol ; 76(Pt 4): 313-325, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32254055

RESUMO

Cryo-electron microscopy (cryo-EM) has rapidly expanded with the introduction of direct electron detectors, improved image-processing software and automated image acquisition. Its recent adoption by industry, particularly in structure-based drug design, creates new requirements in terms of reliability, reproducibility and throughput. In 2016, Thermo Fisher Scientific (then FEI) partnered with the Medical Research Council Laboratory of Molecular Biology, the University of Cambridge Nanoscience Centre and five pharmaceutical companies [Astex Pharmaceuticals, AstraZeneca, GSK, Sosei Heptares and Union Chimique Belge (UCB)] to form the Cambridge Pharmaceutical Cryo-EM Consortium to share the risks of exploring cryo-EM for early-stage drug discovery. The Consortium expanded with a second Themo Scientific Krios Cryo-EM at the University of Cambridge Department of Materials Science and Metallurgy. Several Consortium members have set up in-house facilities, and a full service cryo-EM facility with Krios and Glacios has been created with the Electron Bio-Imaging Centre for Industry (eBIC for Industry) at Diamond Light Source (DLS), UK. This paper will cover the lessons learned during the setting up of these facilities, including two Consortium Krios microscopes and preparation laboratories, several Glacios microscopes at Consortium member sites, and a Krios and Glacios at eBIC for Industry, regarding site evaluation and selection for high-resolution cryo-EM microscopes, the installation process, scheduling, the operation and maintenance of the microscopes and preparation laboratories, and image processing.


Assuntos
Microscopia Crioeletrônica/instrumentação , Processamento de Imagem Assistida por Computador , Laboratórios/organização & administração , Instalações Industriais e de Manufatura/organização & administração , Descoberta de Drogas , Indústria Farmacêutica , Reprodutibilidade dos Testes , Universidades
3.
Annu Rev Biochem ; 88: 113-135, 2019 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-30830798

RESUMO

Integrative structure modeling computationally combines data from multiple sources of information with the aim of obtaining structural insights that are not revealed by any single approach alone. In the first part of this review, we survey the commonly used sources of structural information and the computational aspects of model building. Throughout the past decade, integrative modeling was applied to various biological systems, with a focus on large protein complexes. Recent progress in the field of cryo-electron microscopy (cryo-EM) has resolved many of these complexes to near-atomic resolution. In the second part of this review, we compare a range of published integrative models with their higher-resolution counterparts with the aim of critically assessing their accuracy. This comparison gives a favorable view of integrative modeling and demonstrates its ability to yield accurate and informative results. We discuss possible roles of integrative modeling in the new era of cryo-EM and highlight future challenges and directions.


Assuntos
Microscopia Crioeletrônica/métodos , Cristalografia por Raios X/métodos , Espectroscopia de Ressonância Magnética/métodos , Espectrometria de Massas/métodos , Modelos Moleculares , Proteínas/ultraestrutura , Reagentes de Ligações Cruzadas/química , Microscopia Crioeletrônica/história , Microscopia Crioeletrônica/instrumentação , Cristalografia por Raios X/história , Cristalografia por Raios X/instrumentação , História do Século XX , História do Século XXI , Espectroscopia de Ressonância Magnética/história , Espectroscopia de Ressonância Magnética/instrumentação , Espectrometria de Massas/história , Espectrometria de Massas/instrumentação , Conformação Proteica , Proteínas/química , Software
4.
Methods Enzymol ; 579: 1-17, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27572721

RESUMO

Direct electron detectors have played a key role in the recent increase in the power of single-particle electron cryomicroscopy (cryoEM). In this chapter, we summarize the background to these recent developments, give a practical guide to their optimal use, and discuss future directions.


Assuntos
Técnicas Biossensoriais/métodos , Microscopia Crioeletrônica/métodos , Elétrons , Software , Proteínas de Bactérias/ultraestrutura , Técnicas Biossensoriais/história , Técnicas Biossensoriais/instrumentação , Microscopia Crioeletrônica/história , Microscopia Crioeletrônica/instrumentação , Escherichia coli/química , Escherichia coli/enzimologia , História do Século XX , História do Século XXI , Método de Monte Carlo , Silício/química , beta-Galactosidase/ultraestrutura
5.
Cryo Letters ; 33(5): 349-62, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23224368

RESUMO

This study aimed at evaluating the feasibility of slow freezing for cryopreservation of germinal vesicle (GV) stage porcine oocytes. In this study, intracellular ice formation (IIF) characteristics of GV porcine oocytes were investigated by using a thermoelectric cooling (TEC) cryomicroscope system. This cryomicroscope system used a thermoelectric cooling (TEC) chip in its cold stage as a heat sink and employed a PID control algorithm to achieve accurate temperature control. The temperature was controlled to a range between 70 degree C and -55 degree C with an accuracy of +/- 0.5 degree C. Five constant cooling rates of 24, 12, 6, 3 and 1.5 degree C/min were tested in experiments in freezing GV porcine oocytes from 20 degree C to -50 degree C in an NCSU-23 medium plus 2.0 M DMSO. The IIF temperature of each individual oocyte was recorded and cumulative IIF probabilities were calculated for each cooling rate. The total cumulative probabilities of IIF temperature distribution were 100 percent, 100 percent, 50.0 percent, 54.3 percent and 58.6 percent at cooling rates of 24, 12, 6, 3 and 1.5 degree C/min, respectively. A Weibull distribution model was found to adequately describe the distribution of IIF temperatures of GV porcine oocytes for the cooling rates tested (R2 = 0.858 +/- 0.09). The IIF experimental results indicate that cooling rates of 6, 3 and 1.5°C/min could be considered as possible cryopreservation protocols. Further experiments were performed to examine the feasibility of using these protocols to cryopreserve GV porcine oocytes. After 44 h of in-vitro maturation in NCSU-23, the survival of thawed oocytes was checked. Porcine oocytes developed from the GV stage to the MII stage by using Hoechst 33258 staining, followed by Lacmoid staining as a secondary check. Normalized survival rates of 37.7 +/- 4.6 percent, 45.0 4.4 percent and 45.4 +/- 5.9 percent were obtained for GV oocytes frozen at 1.5, 3 and 6 degree C/min, respectively. The experimental results indicate that slow freezing is a feasible approach for cryopreservation of GV porcine oocytes when cooling rate is properly selected. This study also demonstrated an efficient approach for investigating optimal cooling rates by assessing the IIF characteristics of GV porcine COCs.


Assuntos
Criopreservação/veterinária , Gelo/análise , Oócitos/citologia , Animais , Sobrevivência Celular , Microscopia Crioeletrônica/instrumentação , Criopreservação/métodos , Crioprotetores/química , Citoplasma/química , Desenho de Equipamento , Feminino , Congelamento , Oócitos/química , Suínos
6.
J Vis Exp ; (52)2011 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-21673645

RESUMO

The coupling of cryo-light microscopy (cryo-LM) and cryo-electron microscopy (cryo-EM) poses a number of advantages for understanding cellular dynamics and ultrastructure. First, cells can be imaged in a near native environment for both techniques. Second, due to the vitrification process, samples are preserved by rapid physical immobilization rather than slow chemical fixation. Third, imaging the same sample with both cryo-LM and cryo-EM provides correlation of data from a single cell, rather than a comparison of "representative samples". While these benefits are well known from prior studies, the widespread use of correlative cryo-LM and cryo-EM remains limited due to the expense and complexity of buying or building a suitable cryogenic light microscopy stage. Here we demonstrate the assembly, and use of an inexpensive cryogenic stage that can be fabricated in any lab for less than $40 with parts found at local hardware and grocery stores. This cryo-LM stage is designed for use with reflected light microscopes that are fitted with long working distance air objectives. For correlative cryo-LM and cryo-EM studies, we adapt the use of carbon coated standard 3-mm cryo-EM grids as specimen supports. After adsorbing the sample to the grid, previously established protocols for vitrifying the sample and transferring/handling the grid are followed to permit multi-technique imaging. As a result, this setup allows any laboratory with a reflected light microscope to have access to direct correlative imaging of frozen hydrated samples.


Assuntos
Microscopia Crioeletrônica/instrumentação , Microscopia Crioeletrônica/métodos , Microscopia/instrumentação , Microscopia/métodos , Microscopia Crioeletrônica/economia , Luz , Microscopia/economia , Leveduras/citologia
7.
Curr Opin Struct Biol ; 17(5): 549-55, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17913494

RESUMO

Due to the increasing popularity of electron cryo-microscopy (cryoEM) in the structural analysis of large biological molecules and macro-molecular complexes and the need for simple, rapid and efficient readout, there is a persuasive need for improved detectors. Commercial detectors, based on phosphor/fibre optics-coupled CCDs, provide adequate performance for many applications, including electron diffraction. However, due to intrinsic light scattering within the phosphor, spatial resolution is limited. Careful measurements suggest that CCDs have superior performance at lower resolution while all agree that film is still superior at higher resolution. Consequently, new detectors are needed based on more direct detection, thus avoiding the intermediate light conversion step required for CCDs. Two types of direct detectors are discussed in this review. First, there are detectors based on hybrid technology employing a separate pixellated sensor and readout electronics connected with bump bonds-hybrid pixel detectors (HPDs). Second, there are detectors, which are monolithic in that sensor and readout are all in one plane (monolithic active pixel sensor, MAPS). Our discussion is centred on the main parameters of interest to cryoEM users, viz. detective quantum efficiency (DQE), resolution or modulation transfer function (MTF), robustness against radiation damage, speed of readout, signal-to-noise ratio (SNR) and the number of independent pixels available for a given detector.


Assuntos
Microscopia Crioeletrônica/instrumentação , Microscopia Crioeletrônica/estatística & dados numéricos , Eletrônica Médica/instrumentação , Eletrônica Médica/estatística & dados numéricos , Elétrons , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Substâncias Macromoleculares/química , Método de Monte Carlo
8.
Ultramicroscopy ; 107(4-5): 401-13, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17140733

RESUMO

The electron imaging performance of Medipix2 is described. Medipix2 is a hybrid pixel detector composed of two layers. It has a sensor layer and a layer of readout electronics, in which each 55 microm x 55 microm pixel has upper and lower energy discrimination and MHz rate counting. The sensor layer consists of a 300 microm slab of pixellated monolithic silicon and this is bonded to the readout chip. Experimental measurement of the detective quantum efficiency, DQE(0) at 120 keV shows that it can reach approximately 85% independent of electron exposure, since the detector has zero noise, and the DQE(Nyquist) can reach approximately 35% of that expected for a perfect detector (4/pi(2)). Experimental measurement of the modulation transfer function (MTF) at Nyquist resolution for 120 keV electrons using a 60 keV lower energy threshold, yields a value that is 50% of that expected for a perfect detector (2/pi). Finally, Monte Carlo simulations of electron tracks and energy deposited in adjacent pixels have been performed and used to calculate expected values for the MTF and DQE as a function of the threshold energy. The good agreement between theory and experiment allows suggestions for further improvements to be made with confidence. The present detector is already very useful for experiments that require a high DQE at very low doses.


Assuntos
Microscopia Crioeletrônica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Simulação por Computador , Microscopia Crioeletrônica/instrumentação , Método de Monte Carlo , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA