Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 372
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 343, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493123

RESUMO

INTRODUCTION: Root canal treatment procedures require a thorough understanding of root and canal anatomy. The purpose of this systematic review was to examine the morphological differences of teeth root and their canals assessed using cone-beam computed and micro-computed tomography in Saudi Arabian population. METHODOLOGY: An electronic search was conducted in PubMed / Medline, Scopus, Google Scholar, and Web of Science databases until January 2023 to retrieve related studies. "Root canal morphology," "Saudi Arabia," "Micro-CT," and "cone-beam computed tomography" were used as keywords. A modified version of previously published risk of bias assessment tool was used to determine the quality assessment of included studies. RESULTS: The literature search revealed 47 studies that matched the criteria for inclusion, out of which 44 studies used cone beam computed tomography (CBCT) and three were micro-computed tomography (micro-CT) studies. According to the modified version of risk of bias assessment tool, the studies were categorized as low, moderate, and high risk of bias. A total of 47,612 samples were included which comprised of either maxillary teeth (5,412), or mandibular teeth (20,572), and mixed teeth (21,327). 265 samples were used in micro-CT studies while 47,347 teeth samples were used in CBCT studies. Among the CBCT studies, except for three, all the studies were retrospective studies. Frequently used imaging machine and software were 3D Accuitomo 170 and Morita's i-Dixel 3D imaging software respectively. Minimum and maximum voxel sizes were 75 and 300 µm, Vertucci's classification was mostly used to classify the root canal morphology of the teeth. The included micro-CT studies were in-vitro studies where SkyScan 1172 X-ray scanner was the imaging machine with pixel size ranging between 13.4 and 27.4 µm. Vertucci, Ahmed et al. and Pomeranz et al. classifications were applied to classify the root canal morphology. CONCLUSION: This systematic review revealed wide variations in root and canal morphology of Saudi population using high resolution imaging techniques. Clinicians should be aware of the common and unusual root and canal anatomy before commencing root canal treatment. Future micro-CT studies are needed to provide additional qualitative and quantitative data presentations.


Assuntos
Cavidade Pulpar , Dentição Permanente , Humanos , Arábia Saudita , Microtomografia por Raio-X , Estudos Retrospectivos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia
2.
Clin Oral Investig ; 28(3): 201, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38453706

RESUMO

OBJECTIVES: The aim of this study was to assess cone beam computed tomography (CBCT) as a root canal anatomy diagnostic tool by comparison with micro-CT gold-standard. MATERIALS AND METHODS: 216 two-rooted mandibular molars were first scanned in a CBCT device (200 µm voxel size) and posteriorly in a micro-CT scanner (19.61 µm). The volumes were sequentially screened to classify main root canal anatomy according to Vertucci classification, and for the presence of lateral canals and apical deltas, in both mesial and distal roots. RESULTS: Both methods revealed a higher prevalence of Vertucci Type II and IV in the mesial root, and Vertucci Type I in the distal root. The percentage of agreement for main root canal anatomy classification between CBCT and micro-CT scores was high (85.2%). CONCLUSION: Sensibility to detect both lateral canals and apical deltas with CBCT was low. These results attest to the fact that minor anatomical changes might be difficult to identify with CBCT imaging, hampering its diagnostic value.


Assuntos
Cavidade Pulpar , Mandíbula , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Microtomografia por Raio-X , Mandíbula/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia
3.
Evolution ; 78(4): 778-786, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38285759

RESUMO

Land snails exhibit an extraordinary variety of shell shapes. The way shells are constructed underlies biological and mechanical constraints that vary across gastropod clades. Here, we quantify shell geometry of the two largest groups, Stylommatophora and Cyclophoroidea, to assess the potential causes for variation in shell shape and its relative frequency. Based on micro-computed tomography scans, we estimate material efficiency through 2D and 3D generalizations of the isoperimetric ratio, quantifying the ratios between area and perimeter of whorl cross-sections (2D) and shell volume and surface (3D), respectively. We find that stylommatophorans optimize material usage through whorl overlap, which may have promoted the diversification of flat-shelled species. Cyclophoroids are bound to a circular cross-section because of their operculum; flat shells are comparatively rare. Both groups show similar solutions for tall shells, where local geometry has a smaller effect because of the double overlap between previous and current whorls. Our results suggest that material efficiency is a driving factor in the selection of shell geometry. Essentially, the evolutionary success of Stylommatophora likely roots in their higher flexibility to produce an economic shell.


Assuntos
Exoesqueleto , Caramujos , Animais , Microtomografia por Raio-X , Caramujos/genética , Evolução Biológica
4.
J Prosthet Dent ; 131(3): 479-486, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36890000

RESUMO

STATEMENT OF PROBLEM: The fit of removable partial denture frameworks should be assessed to optimize clinical adaptation. Potential discrepancies between framework and supporting structures are typically precisely measured with negative subtracts and high-resolution equipment. The growth of computer-aided engineering technology allows the development of new methods for the direct evaluation of discrepancies. However, how the methods compare is unclear. PURPOSE: The purpose of this in vitro study was to compare 2 digital methods of fit assessment based on direct digital superimposition and microcomputed tomography indirect analysis. MATERIAL AND METHODS: Twelve cobalt chromium removable partial denture frameworks were fabricated by conventional lost-wax casting or additive manufacturing techniques. The thickness of the gap between occlusal rests and respective definitive cast rest seats (n=34) was evaluated by using 2 different digital methods. Silicone elastomer impressions of the gaps were obtained, and microcomputed tomography measurements were used as controls for validation purposes. Digitization of the framework, the respective definitive cast, and the combination was followed by digital superimposition and direct measurements with the Geomagic Control X software program. Because normality and homogeneity of variance were not verified (Shapiro-Wilk and Levene tests, P<.05), the data were analyzed with Wilcoxon signed rank and Spearman correlation tests (α=.05). RESULTS: The thicknesses measured by microcomputed tomography (median=242 µm) and digital superimposition (median=236 µm) did not reveal statistically significant differences (P=.180). A positive correlation (ρ=0.612) was detected between the 2 methods of assessing fit. CONCLUSIONS: The frameworks presented median gap thicknesses under the limit of clinical acceptability without differences between the proposed methods. The digital superimposition method was determined to be as acceptable as the high-resolution microcomputed tomography method for assessing removable partial denture framework fit.


Assuntos
Prótese Parcial Removível , Microtomografia por Raio-X , Projetos de Pesquisa , Cromo , Cobalto
5.
Aust Endod J ; 50(1): 40-51, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37849412

RESUMO

This study aims to assess the influence of root canal preparation, irrigation needle design and its placement depth in the irrigation flow of confluent canals during syringe irrigation. A mandibular molar presenting two confluent canals in its mesial root was sequentially prepared and scanned by micro-computed tomography after mechanical preparation up to ProTaper Next system sizes X2 (25/.06v), X3 (30/.07v) and X4 (40/.06v). In each of the root canal preparation models, a side-vented and an open-ended needle at 5, 3 and 2 mm from the working length were included, and irrigation flow was assessed by a validated computational fluid dynamics model. The results revealed that the irrigant flowed out of the confluent canals mainly through the canal that did not have the needle. Apical penetration and renewal of the irrigant were most efficiently achieved with the use of a 30G open-ended needle and a 30/.07v preparation.


Assuntos
Cavidade Pulpar , Hidrodinâmica , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Seringas , Irrigantes do Canal Radicular , Irrigação Terapêutica , Preparo de Canal Radicular
6.
J Mech Behav Biomed Mater ; 150: 106269, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38043259

RESUMO

BACKGROUND: The stud-shaped attachment systems (AS) with different shape designs (ball, cylindrical, conical) and materials (metallic, plastic, or a combination of both) are commonly used to provide better retention and stability in implant-retained mandibular overdentures (IRMO). PURPOSE: The purpose of the present study was to evaluate and compare the retention loss and the wear (patterns, location, material loss) of three resilient unsplinted AS: a well-established ball attachment system (BAS) and two more recent cylindrical attachment systems (CAS), Locator R-Tx® and Novaloc®. MATERIALS AND METHODS: The implants, their corresponding abutments, the color-coded or position-coded retention devices (RD), the matrix metal housing were incorporated within CAD/CAM resin blocks and cyclically loaded with 19.6 N along the implant axis in a chewing machine to simulate 10,000 insertion-removal cycles (IRC). At cycle 10, 100, 1,000, 5,000, and 10,000, the retention force was measured using a universal testing machine. The wear was qualitatively examined using a binocular magnifier for both systems, and quantitatively assessed from micro-computed tomography acquisitions for CAS. Material loss exceeding 50 µm was considered significant. RESULTS: The three AS showed different retentive behavior along time. All the Locator R-Tx® RD lost more than 50 % of their retention after 10,000 IRC. The retention of the Ball System slightly varied over time, the final retention loss in Bmed and Bmax groups being lower than 25 % of the initial retention. Wear was located at the tip of their gold RD and at the equator area of their ball abutment. For Locator R-Tx®, the more retentive the plastic RD, the greater its wear and retention loss. Only Novaloc® maintained a stable retention with even a slight tendency to increase and showed a negligible wear. Implant abutments of the CAS showed no significant wear. CONCLUSION: After 10,000 IRC, corresponding to approximately 5-years clinical use, almost all RD provided retention force over 5 N, which could be sufficient to maintain satisfaction in most of the patients. The retention loss observed most prominently for the Locator R-Tx®, then for the Ball System, seemed to correlate with the wear observed on their RD. The practitioner may expect less RD maintenance with the Novaloc® stable retention overtime.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Humanos , Retenção de Dentadura/métodos , Microtomografia por Raio-X , Mandíbula , Análise do Estresse Dentário
7.
Microsc Res Tech ; 87(4): 705-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37983687

RESUMO

There are technical challenges in imaging studies that can three-dimensionally (3D) analyze a single fiber (SF) to observe the functionality of the entire muscle after stroke. This study proposes a 3D assessment technique that only segments the SF of the right stroke-induced soleus muscle of a gerbil using synchrotron radiation x-ray microcomputed tomography (SR-µCT), which is capable of muscle structure analysis. Curvature damage in the SF of the left soleus muscle (impaired) progressed at 7-day intervals after the stroke in the control; particularly on the 7 days (1 week) and 14 days (2 weeks), as observed through visualization analysis. At 2 weeks, the SF volume was significantly reduced in the control impaired group (p = .033), and was significantly less than that in the non-impaired group (p = .009). We expect that animal post-stroke studies will improve the basic field of rehabilitation therapy by diagnosing the degree of SF curvature. RESEARCH HIGHLIGHTS: Muscle evaluation after ischemic stroke using synchrotron radiation x-ray microcomputed tomography (SR-µCT). Curvature is measured by segmenting a single fiber (SF) in the muscle. Structural changes in the SF of impaired gerbils at 7-day intervals were assessed.


Assuntos
Músculos , Animais , Microtomografia por Raio-X , Microscopia de Contraste de Fase , Gerbillinae
8.
Ann Biomed Eng ; 52(4): 832-844, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38151645

RESUMO

Noninvasive methods to detect microstructural changes in collagen-based fibrous tissues are necessary to differentiate healthy from damaged tissues in vivo but are sparse. Diffusion Tensor Imaging (DTI) is a noninvasive imaging technique used to quantitatively infer tissue microstructure with previous work primarily focused in neuroimaging applications. Yet, it is still unclear how DTI metrics relate to fiber microstructure and function in musculoskeletal tissues such as ligament and tendon, in part because of the high heterogeneity inherent to such tissues. To address this limitation, we assessed the ability of DTI to detect microstructural changes caused by mechanical loading in tissue-mimicking helical fiber constructs of known structure. Using high-resolution optical and micro-computed tomography imaging, we found that static and fatigue loading resulted in decreased sample diameter and a re-alignment of the macro-scale fiber twist angle similar with the direction of loading. However, DTI and micro-computed tomography measurements suggest microstructural differences in the effect of static versus fatigue loading that were not apparent at the bulk level. Specifically, static load resulted in an increase in diffusion anisotropy and a decrease in radial diffusivity suggesting radially uniform fiber compaction. In contrast, fatigue loads resulted in increased diffusivity in all directions and a change in the alignment of the principal diffusion direction away from the constructs' main axis suggesting fiber compaction and microstructural disruptions in fiber architecture. These results provide quantitative evidence of the ability of DTI to detect mechanically induced changes in tissue microstructure that are not apparent at the bulk level, thus confirming its potential as a noninvasive measure of microstructure in helically architected collagen-based tissues, such as ligaments and tendons.


Assuntos
Imagem de Tensor de Difusão , Neuroimagem , Humanos , Microtomografia por Raio-X , Fadiga , Colágeno , Anisotropia
9.
Braz Oral Res ; 37: e099, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38055517

RESUMO

This study aimed to investigate whether two acquisition parameters, voxel size and filter thickness, used in a micro-computed tomography (micro-CT) scan, together with the examiner's experience, influence the outcome of bone repair analysis in an experimental model. Bone defects were created in rat tibiae and scanned using two voxel sizes of 6- or 12-µm and two aluminum filter thickness of 0.5- or 1-mm. Then, bone volume fraction (BV/TV) and trabecular thickness (Tb.Th) were analyzed twice by two groups of operators: experienced and inexperienced examiners. For BV/TV, no significant differences were found between scanning voxel sizes of 6 and 12 µm for the experienced examiners; however, for the inexperienced examiners, the analysis performed using a 12-µm voxel size resulted in higher BV/TV values (32.4 and 32.9) than those acquired using a 6-µm voxel size (25.4 and 24.8) (p < 0.05). For Tb.Th, no significant differences between the analyses performed by experienced and inexperienced groups were observed when using the 6-µm voxel size. However, inexperienced examiners' analysis revealed higher Tb.Th values when using the 12-µm voxel size compared with 6 µm (0.05 vs. 0.03, p < 0.05). Filter thickness had no influence on the results of any group. In conclusion, voxel size and operator experience affected the measured Tb.Th and BV/TV of a region with new bone formation. Operator experience in micro-CT analysis is more critical for BV/TV than for Tb.Th, whereas voxel size significantly affects Tb.Th evaluation. Operators in the initial phases of research training should be calibrated for bone assessments.


Assuntos
Osso e Ossos , Tíbia , Animais , Ratos , Microtomografia por Raio-X , Tíbia/diagnóstico por imagem , Densidade Óssea
10.
Clin Oral Investig ; 27(12): 7489-7499, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37971540

RESUMO

OBJECTIVES: The aim was to compare the porosity of different bulk-fill resin-based composites (RBCs) placement techniques to the conventional incremental technique using microcomputed tomography (µ-CT). MATERIAL AND METHODS: Occlusal cavities were prepared on extracted human molars, divided into five groups based on the placement technique (n = 10/group). Techniques examined were Monoblock-two-step (SureFil SDR flow + Ceram.X), Monoblock-two-step (Tetric EvoFlow Bulk-Fill + Tetric EvoCeram Bulk-Fill), Monoblock-one-step (Tetric EvoCeram Bulk-Fill), Monoblock with sonic activation (SonicFill2), and incremental technique (Filtek Z250). µ-CT scanning (SkyScan, Bruker, Belgium) assessed the number, volume of closed pores, and total porosity. Analysis of variance on ranks was used (Student-Newman-Keuls method and Mann-Whitney rank-sum test), to determine the significance of RBC viscosity and the sonication placement technique. The Spearman correlation method assessed the correlation between porosity characteristics (α = 0.05). RESULTS: The SonicFill2 presented a higher number of closed pores than the other groups (p < 0.05). The overall porosity within the restoration seemed greater in this order: Filtek Z250 > SonicFill2 > Tetric EvoFlow Bulk-Fill + Tetric EvoCeram Bulk-Fill > Tetric EvoCeram Bulk-Fill > SureFil SDR Flow + Ceram.X. Sonication was associated with increased number (p = 0.005) and volume (p = 0.036) of closed pores. A strong correlation was observed between the number and volume of closed pores (R2 = 0.549, p < 001). CONCLUSIONS: The monoblock technique with sonic activation showed significantly more internal porosity than the other placement techniques. Sonication during application contributed to the higher number and volume of closed pores than the passive bulk-fill application. CLINICAL RELEVANCE: Using bulk-fill materials enhances efficiency, yet void formation remains an issue, depending on viscosity and active/passive delivery of materials. Clinicians must familiarize themselves with effective placement techniques to reduce void formation and optimizing treatment outcomes.


Assuntos
Resinas Compostas , Materiais Dentários , Humanos , Microtomografia por Raio-X , Porosidade , Teste de Materiais , Viscosidade , Restauração Dentária Permanente/métodos
11.
Sci Rep ; 13(1): 20181, 2023 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-37978269

RESUMO

Ultra-high dose rate (UHDR) radiotherapy (RT) or FLASH-RT can potentially reduce normal tissue toxicity. A small animal irradiator that can deliver FLASH-RT treatments similar to clinical RT treatments is needed for pre-clinical studies of FLASH-RT. We designed and simulated a novel small animal FLASH irradiator (SAFI) based on distributed x-ray source technology. The SAFI system comprises a distributed x-ray source with 51 focal spots equally distributed on a 20 cm diameter ring, which are used for both FLASH-RT and onboard micro-CT imaging. Monte Carlo simulation was performed to estimate the dosimetric characteristics of the SAFI treatment beams. The maximum dose rate, which is limited by the power density of the tungsten target, was estimated based on finite-element analysis (FEA). The maximum DC electron beam current density is 2.6 mA/mm2, limited by the tungsten target's linear focal spot power density. At 160 kVp, 51 focal spots, each with a dimension of [Formula: see text] mm2 and 10° anode angle, can produce up to 120 Gy/s maximum DC irradiation at the center of a cylindrical water phantom. We further demonstrate forward and inverse FLASH-RT planning, as well as inverse-geometry micro-CT with circular source array imaging via numerical simulations.


Assuntos
Radiometria , Tungstênio , Animais , Raios X , Doses de Radiação , Microtomografia por Raio-X , Imagens de Fantasmas , Dosagem Radioterapêutica , Método de Monte Carlo
12.
Forensic Sci Int ; 352: 111851, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37801865

RESUMO

BACKGROUND: Although various methods for age-at-death estimation of skeletal remains are available, this is still an unsolved issue in forensic anthropology, especially concerning elderly individuals. Moreover, the lack of population-specific methods often made age-at-death estimation unreliable in other populations. AIM: Our study aimed to examine whether micro-computed tomography (micro-CT) analysis of pubic bone samples obtained from the contemporary Serbian population could be used in anthropological and forensic practice for age-at-death estimation. METHODOLOGY: This study encompassed 62 pubic samples obtained from 26 adult male and 36 adult female cadaveric donors (age range: 22-91 years). Initially, staging according to the Suchey-Brooks phases was performed by two experienced investigators, followed by micro-CT assessment of pubic bone trabecular and cortical compartments (spatial resolution of the scans was 10 µm). RESULTS: Our results revealed an age-associated decline in trabecular and cortical micro-architecture of elderly male and female individuals, with the most prominent changes present in trabecular bone volume fraction and total porosity of the anterior and posterior cortical surface of the pubic bone. Those parameters were used to generate age-at-death estimation equations. One sample t-test did not reveal a significant difference between estimated age-at-death and real (known) age-at-death in the overall sample (mean absolute error [MAE] of 4.76 years), female (MAE of 9.66 years) and male cadaveric donors (MAE of 6.10 years, p > 0.05). CONCLUSION: Our data indicated that micro-architectural features of trabecular and cortical compartments of pubic bone could potentially be applied as an additional reliable method for age-at-death estimation in the Serbian population.


Assuntos
Sínfise Pubiana , Adulto , Humanos , Masculino , Feminino , Idoso , Adulto Jovem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Pré-Escolar , Microtomografia por Raio-X , Sínfise Pubiana/diagnóstico por imagem , Sínfise Pubiana/anatomia & histologia , Determinação da Idade pelo Esqueleto/métodos , Antropologia Forense , Cadáver
13.
Clin Oral Investig ; 27(11): 6413-6420, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37704914

RESUMO

AIM: To assess the observed volume of filled C-shaped root canals from different CBCT and micro-CT having nano-CT as a reference. MATERIALS AND METHODS: Twelve extracted mandibular molars with C-shaped root canals were endodontically treated using Reciproc Blue R25 (VDW GMBH, Munich, Germany) in a reciprocating system and filled with gutta-percha (Dentsply Maillefer) and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). CBCT scans were performed using 3 units-3D Accuitomo 170 (J. Morita, Kyoto, Japan), ProMax 3D Max (Planmeca, Helsinki, Finland), and NewTom VGi EVO (Cefla QR, Verona, Italy)-at two resolution modes: standard and high. Micro-CT and nano-CT scans were also obtained. The volume of all filled C-shaped root canals was obtained using CTAn software (Bruker, Kontich, Belgium), and the blooming artifact, in relation to nano-CT volume, was calculated. The data were evaluated by the Bland-Altman plots and ANOVA two-way for repeated measures (α = 0.05). RESULTS: All CBCT units and micro-CT showed significantly larger observed volume of root canal filling when compared to nano-CT. The blooming artifact of root canal filling in standard resolution was significantly larger than that in high resolution (p < 0.05) in all CBCT units. CONCLUSIONS: Endodontic filling material with AH Plus sealer causes blooming artifacts in CBCT units and micro-CT. CLINICAL RELEVANCE: Considering the anatomical complexity of C-shaped root canals and the challenges associated with endodontic treatment, CBCT is frequently recommended for follow-up evaluations. However, the presence of endodontic filling material can result in blooming artifacts that may potentially impact the accurate diagnosis of endodontic complications.


Assuntos
Materiais Restauradores do Canal Radicular , Cavidade Pulpar , Microtomografia por Raio-X , Preparo de Canal Radicular , Retratamento , Guta-Percha , Obturação do Canal Radicular , Tomografia Computadorizada de Feixe Cônico
14.
Micron ; 174: 103533, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37660476

RESUMO

Micro-computed tomography (micro-CT) provides valuable data for studying soft tissue, though it is often affected by sample movement during scans and low contrast in X-ray absorption. This can result in lower image quality and geometric inaccuracies, collectively known as 'artefacts'. To mitigate these issues, samples can be embedded in hydrogels and enriched with heavy metals for contrast enhancement. However, the long-term durability of these enhancements remains largely unexplored. In this study, we examine the effects of two contrast enhancement agents - iodine and phosphotungstic acid (PTA) - and two hydrogels - agarose and Poloxamer 407 - over a 14-day period. We used Drosophila melanogaster as a test model for our investigation. Our findings reveal that PTA and agarose are highly durable, while iodine and poloxamer hydrogel exhibits higher leakage rates. These observations lay the foundation for estimating contrast stabilities in contrast-enhanced micro-CT with hydrogel embedding and serve to inform future research in this field.


Assuntos
Hidrogéis , Iodo , Animais , Microtomografia por Raio-X , Drosophila melanogaster , Sefarose , Ácido Fosfotúngstico , Poloxâmero
15.
Braz Oral Res ; 37: e081, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37672415

RESUMO

This study tested a novel in vitro dental erosion-abrasion model and the performance of cross-polarization optical coherence tomography (CP-OCT) in longitudinally monitoring the simulated lesions. Thirty human enamel specimens were prepared and randomized to receive three dental erosion-abrasion (EA) protocols: severe (s-EA, lemon juice/pH:2.5/4.25%w/v citric acid), moderate (m-EA, grapefruit juice/pH:3.5/1.03%w/v citric acid) and no-EA (water, control). EA challenge was performed by exposing the specimens to acidic solutions 4x/day and to brushing 2x/day with 1:3 fluoridated toothpaste slurry, for 14 days. Enamel thickness measurements were obtained using CP-OCT at baseline (D0), 7 (D7) and 14 days (D14) and micro-computed tomography (micro-CT) at D14. Enamel surface loss was measured with both CP-OCT and optical profilometry at D0, D7 and D14. Data was analyzed with repeated-measures ANOVA and Pearson's correlation (r) (α = 0.05). CP-OCT enamel thickness decreased over time in the s-EA group (D0 >D7 > D14, p < 0.001) and m-EA group (D0 > D14, p = 0.019) but did not change in the no-EA group (p = 0.30). Overall, CP-OCT and micro-CT results at D14 correlated moderately (r = 0.73). CP-OCT surface loss was highest for s-EA (p <0.001) but did not differ between moderate and no-EA (p = 0.25). Enamel surface loss with profilometry increased with severity (no-EA>m-EA>s-EA, p < 0.001). D14 surface loss was higher than D7 for both methods except for the no-EA group with profilometry. CP-OCT and profilometry had moderate overall correlation (r = 0.70). Our results revealed that the currently proposed in vitro dental erosion-abrasion model is valid and could simulate lesions of different severities over time. CP-OCT was a suitable method for monitoring the EA lesions.


Assuntos
Tomografia de Coerência Óptica , Erosão Dentária , Humanos , Erosão Dentária/diagnóstico por imagem , Microtomografia por Raio-X , Ácido Cítrico , Esmalte Dentário/diagnóstico por imagem
16.
Caries Res ; 57(3): 220-230, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37586341

RESUMO

Early caries diagnosis is crucial to treatment decisions in dentistry and requires identification of lesion activity: whether a carious lesion is active (progressively demineralizing) or arrested (progressively remineralizing). This study aimed to identify microtomographic (micro-CT) differences between active and arrested smooth surface enamel lesions, to quantify those micro-CT differences by creating thresholds for ex vivo caries activity assessment to serve as a future reference standard, and to validate those thresholds against the remaining sample. Extracted human permanent teeth (n = 59) were selected for sound surfaces and non-cavitated smooth surface carious lesions. Each surface was then examined for caries activity by calibrated individuals via visual-tactile examination using the International Caries Classification and Management System (ICCMS) activity criteria. Each tooth was scanned via micro-CT and the mineral density was plotted against lesion depth. The area under the curve (AUC) was calculated and represented the loss of density for the outermost 96 µm of enamel. AUC thresholds obtained from micro-CT were established to classify sound, remineralized, and demineralized surfaces against the gold standard examiner's lesion assessment of sound, inactive, and active lesions, respectively. The established AUC thresholds demonstrated moderate agreement with the assessment in identifying demineralized lesions (k = 0.45), with high sensitivity (0.73) and specificity (0.77). This study demonstrated quantifiable differences among demineralized lesions, remineralized lesions, and sound surfaces, which contributes to the establishment of micro-CT as a reference standard for caries activity that may be used to improve clinical and laboratorial dental caries evaluations.


Assuntos
Cárie Dentária , Dente , Humanos , Cárie Dentária/diagnóstico , Microtomografia por Raio-X/métodos , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/patologia , Minerais
17.
J Biomech Eng ; 145(11)2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37417814

RESUMO

Noninvasive compression-induced anterior cruciate ligament rupture (ACL-R) is an easy and reproducible model for studying post-traumatic osteoarthritis (PTOA) in mice. However, equipment typically used for ACL-R is expensive, immobile, and not available to all researchers. In this study, we compared PTOA progression in mice injured with a low-cost custom ACL-rupture device (CARD) to mice injured with a standard system (ElectroForce 3200). We quantified anterior-posterior (AP) joint laxity immediately following injury, epiphyseal trabecular bone microstructure, and osteophyte volume at 2 and 6 weeks post injury using micro-computed tomography, and osteoarthritis progression and synovitis at 2 and 6 weeks post injury using whole-joint histology. We observed no significant differences in outcomes in mice injured with the CARD system compared to mice injured with the Electroforce (ELF) system. However, AP joint laxity data and week 2 micro-CT and histology outcomes suggested that injuries may have been slightly more severe and PTOA progressed slightly faster in mice injured with the CARD system compared to the ELF system. Altogether, these data confirm that ACL-R can be successfully and reproducibly performed with the CARD system and that osteoarthritis (OA) progression is mostly comparable to that of mice injured with the ELF system, though potentially slightly faster. The CARD system is low cost and portable, and we are making the plans and instructions freely available to all interested investigators in the hopes that they will find this system useful for their studies of OA in mice.


Assuntos
Lesões do Ligamento Cruzado Anterior , Instabilidade Articular , Osteoartrite , Camundongos , Animais , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Microtomografia por Raio-X , Osteoartrite/diagnóstico por imagem
18.
J Biophotonics ; 16(10): e202300165, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37316468

RESUMO

The aim of this study was to develop a clinical SWIR reflectance handpiece to assess the activity of lesions on the occlusal surfaces. The time-resolved reflectivity of 10 active and 10 arrested occlusal caries lesions on extracted teeth was monitored at 1470 nm using a benchtop system and a modified clinical prototype during forced air drying. The presence of a highly mineralized surface layer measured with microcomputed tomography (microCT) was used to indicate lesion activity. Multiple kinetic parameters were extracted from the acquired SWIR time versus intensity dehydration curves and used to assess lesion activity. Three parameters: delay, %Ifin , and rate calculated from the SWIR dehydration curves were significantly different (p < 0.05) between active and arrested lesions. The modified clinical probe was able to completely dehydrate all the active lesion areas in the occlusal pits and fissures in less than 30 s.


Assuntos
Desidratação , Cárie Dentária , Humanos , Suscetibilidade à Cárie Dentária , Microtomografia por Raio-X , Tomografia de Coerência Óptica/métodos , Cinética , Cárie Dentária/diagnóstico por imagem
19.
J Dent ; 135: 104602, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37391026

RESUMO

OBJECTIVE: To identify the remineralization activity of enamel subsurface lesions using different percentages of surface pre-reacted glass-ionomer (S-PRG) filler containing gum-base material. METHODS: Gum extracts from gum-base materials containing 0wt%, 5wt%, and 10wt% S-PRG filler were prepared as GE0, GE5, and GE10, respectively. A total of 50 bovine enamel specimens were used, and the polished enamel surface of a 3 × 3 mm2 window area was exposed. The specimens were then subjected to a demineralization solution for seven days to create a subsurface enamel lesion. Remineralization was then conducted for seven days using a protocol whereby the specimens were immersed three times a day in prepared gum extracts (0wt%, 5wt%, and 10wt%) and artificial saliva of pH 7 (Control) for 20 min at 37 °C. Thereafter, remineralization assessment was performed by using Swept Source Optical Coherence Tomography (SS-OCT) and micro-computed tomography (µCT). Surface morphology and elemental analysis were conducted by scanning electron microscopy (SEM) and energy-dispersive X-ray spectrometry (EDS). RESULTS: The depths of the demineralized lesions in the GE5 and GE10 groups were significantly lower than those of the Control and the GE0 groups. SEM observations of the enamel surface morphology of the GE5 and GE10 groups indicated remineralization with S-PRG filler-related elements present. CONCLUSION: The GE5 and GE10 S-PRG filler containing gum-base materials showed significantly improved surface remineralization and reduced demineralization of the enamel lesions. EDS analysis suggested that the released ions from the S-PRG filler might be responsible for surface remineralization. CLINICAL SIGNIFICANCE: The S-PRG filler containing gum-base material may have a significant remineralization effect and improve the surface morphology of enamel subsurface lesions.


Assuntos
Esmalte Dentário , Desmineralização do Dente , Animais , Bovinos , Humanos , Microtomografia por Raio-X , Resinas Acrílicas , Desmineralização do Dente/diagnóstico por imagem , Desmineralização do Dente/tratamento farmacológico , Remineralização Dentária
20.
PeerJ ; 11: e15208, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37131992

RESUMO

Backround: OneReci (MicroMega, Besançon, France) is a recently introduced single-file reciprocating system with scarce information revealed on its shaping ability. This study aimed to compare the shaping abilities of OneReci and a well-documented single-file reciprocating system WaveOne Gold (WOG; Dentsply Maillefer, Ballaigues, Switzerland) and evaluate the effect of increased apical enlargement on the preparation quality, using micro-computed tomography (micro-CT). Methods: After an initial micro-CT scanning, twenty mesial root canals of mandibular molars were anatomically matched. The canals were assigned to two experimental groups (n = 10), using OneReci or WOG in different canals of the same root. The glide paths were created, and root canals were prepared twice, using size 25 and 35 instruments of the systems, respectively. The specimens were scanned with micro-CT after each preparation. The increase in canal volume, amount of dentin removal, unprepared root canal surface, canal transportation, centering ratio and preparation times were assessed. The data were analysed with independent sample t-tests, variance analyses, Friedman and Mann-Whitney U tests. The significance level was set at 5%. Results: Each preparation increased the canal volume and dentin removal while decreasing the unprepared root surface. The difference between the systems became significant after preparation with size 35 instruments (p < 0.05). Regarding canal transportation and centering ratio, the difference was insignificant (p > 0.05). The first preparation step (glide path + size 25 instrument) was significantly faster in the OneReci group (p < 0.05). Conclusions: Preparation with size 25 instruments of the systems appeared to be safe with similar shaping performances. Larger apical preparation promoted significantly higher dentin removal, volume increase, and prepared surface area in WOG.


Assuntos
Ouro , Preparo de Canal Radicular , Microtomografia por Raio-X/métodos , Desenho de Equipamento , Tratamento do Canal Radicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA