J Vasc Surg Venous Lymphat Disord ; 10(2): 482-490, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35026448

RESUMO

BACKGROUND: Percutaneous endovenous stenting has emerged during the past decade as the primary method of treating symptomatic venous outflow obstruction. A recognized complication of venous stenting is stent migration. The aim of the present systematic review was to identify the number of cases of stent migration in reported studies to recognize the risk factors that might be associated with this complication and the outcomes following migration. METHODS: A review was conducted in accordance with the MOOSE (meta-analyses of observational studies in epidemiology) and PRIMSA (preferred reporting items for systematic review and meta-analysis) guidelines and registered in the PROSPERO. MEDLINE, EMBASE, and PubMed databases. Key references were searched using specified keywords. All relevant data for the primary procedure and subsequent presentation with stent migration were retrieved. The data were assessed as too low in quality to allow for statistical analysis. RESULTS: Between 1994 and 2020, 31 studies were identified, including 29 case reports and 2 case series, providing data for 54 events of venous stent migration with some data provided regarding the stent used for 47 of the events. The mean age of the 52 patients with stent migration was 50 years (range, 19-88 years) and 30 were men (57.6%). The stents for most of the reported cases were ≤60 mm in length (38 of 46; 82.6%). Only three of the reports were of stents >14 mm in diameter (3 of 47; 3.6%). None of the studies had reported migration of stents >100 mm long. In 85% of the migrated stent events, retrieval was attempted, with 65.2% via an endovascular approach. The immediate outcome was satisfactory for 100% of the reported attempts, whether by an endovascular or open surgical approach. CONCLUSIONS: The findings from our literature review suggest that the risk of migration is rare but might be underreported. Most of reported cases had occurred with shorter and smaller diameter stents. The paucity of reported data and the short-term follow-up provided suggest that more formal data collection would provide a truer reflection of the incidence. However, clear strategies to avoid migration should be followed to prevent this complication from occurring.


Assuntos
Remoção de Dispositivo , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/epidemiologia , Migração de Corpo Estranho/terapia , Stents , Veias , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Veias/diagnóstico por imagem , Adulto Jovem
2.
J Endovasc Ther ; 28(3): 474-480, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33855876

RESUMO

PURPOSE: Intravascular embolization of hemodialysis and central venous catheters is a rare but potentially serious complication. With the increasing use of catheters in medical practice, we are often faced with this type of complication. Novel, simple, and low-cost techniques are needed for foreign body extraction in order to reduce cardiovascular risks. CASE REPORT: We describe the approach of 5 foreign body embolization cases. Case 1: a 57-year-old woman with end-stage renal failure with a complete fracture and migration of the distal extremity of a hemodialysis catheter. Case 2: a 55-year-old man with an accidental embolization of the distal portion of a hemodialysis catheter. Case 3: a 76-year-old woman with stage IV breast cancer and an accidental embolization of a central venous catheter guidewire. Cases 4 and 5: a 71-year-old woman and a 2-year-old boy with a port-a-cath embolization. All the patients underwent successful minimally invasive removal of the foreign bodies from the thoracic site using 5Fr pigtail catheters. Additional surgery was not required. No further complications, such as damage to the vascular wall, were noted. CONCLUSION: Our experience with the interlacing and traction pigtail show that it is a simple, practical, and low-cost technical alternative and its benefits should be widespread.


Assuntos
Corpos Estranhos , Migração de Corpo Estranho , Idoso , Cateteres de Demora , Pré-Escolar , Remoção de Dispositivo , Falha de Equipamento , Feminino , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/terapia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
J Endovasc Ther ; 26(5): 697-703, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31282253

RESUMO

Purpose: To evaluate chimney stent-graft position and morphological changes of the aneurysm sac as visualized by postoperative computed tomography angiography (CTA) over a minimum 24-month follow-up period. Materials and Methods: Twenty-one patients (mean age 75.7±8.6 years; 20 men) with juxtarenal aortic aneurysms who underwent successful chimney endovascular aneurysm repair (ch-EVAR) with the Endurant stent-graft and had 2 postoperative CTAs separated by at least 24 months were included in the study. CTA-based measurements of aortic stent-graft migration, target vessel angle, and chimney angle were compared between the serial scans. Results: During a mean follow-up of 34.9 months (range 24-69.2), the mean migration of the aortic stent-grafts was under 5 mm (2.76±2.4 mm). The average migration distance per year was 1.15 mm. The aneurysm diameter reduced a mean 3.25 mm (p=0.048). The right renal artery angle moved significantly upward 6.72° (p=0.025), while the right renal chimney stent-graft moved significantly downward 7.83° (p=0.042). The left renal artery angle also moved upward 1.87° (p=0.388) and the corresponding chimney moved downward 5.68° (p=0.133). During the study period, no type I/III endoleak or chimney occlusion was observed. Conclusion: Midterm morphometric assessment of ch-EVAR using CTA showed significant aneurysm sac shrinkage and a stable 3-year position of the abdominal devices, with the mean downward migration of the aortic stent-graft being <5 mm in the majority of cases. The chimney grafts seem to be prone to take an oblique rather than parallel configuration during follow-up. However, there was no relevant clinical consequence related to this phenomenon.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/diagnóstico por imagem , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 93(2): 330-334, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30387234

RESUMO

BACKGROUND/OBJECTIVES: Orbital atherectomy (OA) is routinely being used for plaque modification to facilitate percutaneous revascularization in patients with peripheral arterial disease (PAD) and arterial calcification. Guidewire fracture (GWF) during OA, though anecdotally described, has not been studied in a systematic manner. We conducted a review of the Manufacturer and User Facility Device Experience (MAUDE) database to study the reports of wire fracture and its management and consequences. METHODS: We queried the MAUDE database for all events involving the current generation of the OA device: "Diamondback 360 Peripheral Orbital Atherectomy System", and "Stealth 360° Orbital PAD System". RESULTS: We identified 62 reports of GWF during OA for PAD. The superficial femoral artery was the most commonly involved atherectomy site. The wire fractured at the soft tip in a majority of cases (68%). Embolized wire fragments were left in the patient in 36 cases (58%), retrieved percutaneously in 10 cases (16%), and trapped by a stent against the arterial wall in eight cases (13%). Lastly, eight patients (13%) underwent surgery for removal of the wire fragment. CONCLUSIONS: This is the first published report to study the complication of GWF during peripheral OA. GWF is an uncommon but has significant procedural and clinical consequences. It results in a high rate of ancillary rescue procedures (including surgery) and is associated with a higher risk of arterial thrombosis and complications from wire retrieval attempts. The risk of wire fracture may be avoided with carefully adherence to the IFU.


Assuntos
Aterectomia/instrumentação , Cateterismo Periférico/instrumentação , Remoção de Dispositivo , Falha de Equipamento , Migração de Corpo Estranho/terapia , Doença Arterial Periférica/terapia , Dispositivos de Acesso Vascular , Aterectomia/efeitos adversos , Cateterismo Periférico/efeitos adversos , Bases de Dados Factuais , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Setor de Assistência à Saúde , Humanos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Fatores de Risco , Resultado do Tratamento
5.
PLoS One ; 13(6): e0198752, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29920522

RESUMO

Despite being widely used, ventriculoperitoneal (VP) shunt placement is a procedure often associated with complications and revision surgeries. Many neurosurgical centers routinely perform early postoperative cranial computer tomography (CT) to detect postoperative complications (e.g., catheter malposition, postoperative bleed, over-drainage). Because guidelines are lacking, our study aimed to evaluate the yield of early routine postoperative CT after shunt placement for adult hydrocephalus. We retrospectively reviewed 173 patients who underwent frontal VP shunting for various neurosurgical conditions. Radiological outcomes were proximal catheter malposition, and ventricular width in preoperative and postoperative imaging. Clinical outcomes included postoperative neurological outcome, revision surgery because of catheter malposition or other causes, mortality, and finally surgical, non-surgical, and overall morbidity. In only 3 (1.7%) patients did the early routine postoperative CT lead to revision surgery. Diagnostic ratios for CT finding 1 asymptomatic patient who eventually underwent revision surgery per total number to scan were 1:58 for shunt malposition, 1:86 for hygroma, and 1:173 for a cranial bleed. Five (2.9%) patients with clinically asymptomatic shunt malposition or hygroma underwent intervention based on early postoperative CT (diagnostic ratio 1:25). Shunt malposition occurred in no patient with normal pressure hydrocephalus and 2 (40%) patients with stroke. Lower preoperative Evans' Index was a statistically significant predictor for high-grade shunt malposition. We found a rather low yield for early routine postoperative cranial CT after frontal VP-shunt placement. Therefore, careful selection of patients who might benefit, considering the underlying disease and preoperative radiological findings, could reduce unnecessary costs and exposure to radiation.


Assuntos
Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Derivação Ventriculoperitoneal , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/etiologia , Ventrículos Cerebrais , Grupos Diagnósticos Relacionados , Falha de Equipamento , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Linfangioma Cístico/diagnóstico por imagem , Linfangioma Cístico/etiologia , Masculino , Seleção de Pacientes , Período Pós-Operatório , Reoperação , Estudos Retrospectivos , Derivação Ventriculoperitoneal/efeitos adversos
6.
J Vasc Access ; 18(5): 419-425, 2017 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-28777415

RESUMO

BACKGROUND: Malpositioned central venous access device (CVAD) tip locations can cause significant mechanical and chemical vessel-related injuries and complications if left in inappropriate positions.The aim of this study is to determine the use of a high-flow flush technique (HFFT) in successful correction of malpositioned catheters into the lower superior vena cava or cavoatrial junction and provide a cost comparison to interventional/fluoroscopic-based repositioning. METHODS: This is a retrospective chart and radiographic review of all inserted CVADs found malpositioned between 1996-2014 in a multi-specialty 1000-bed tertiary trauma center in Sydney, Australia.7450 CVADs placed by a nurse-led vascular access service were reviewed. Catheters repositioned pre-2010 were excluded owing to radiology repositioning interventions. RESULTS: There were 3996 peripherally inserted central catheters (PICCs) and 3454 centrally inserted central catheters (CICCs) placed. Seventy-four were malpositioned post-2010. Of these, 53 devices were repositioned using the studied technique; 86% (46/53) of catheters were successfully repositioned on the first HFFT attempt. There was supportive evidence that device insertion side is important in potential catheter malposition. CONCLUSIONS: Clinical outcomes suggest that CICCs and PICCs may be successfully repositioned utilizing this technique, with no adverse events associated and a prospective cost saving benefit when compared to interventional-based repositioning procedures.


Assuntos
Cateterismo Venoso Central/economia , Cateterismo Venoso Central/instrumentação , Cateteres Venosos Centrais/economia , Migração de Corpo Estranho/economia , Migração de Corpo Estranho/terapia , Custos Hospitalares , Radiografia Intervencionista/economia , Irrigação Terapêutica/economia , Angiografia Digital/economia , Cateterismo Venoso Central/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , New South Wales , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Irrigação Terapêutica/efeitos adversos , Centros de Traumatologia , Resultado do Tratamento
8.
Echocardiography ; 34(6): 915-918, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28512744

RESUMO

Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures.


Assuntos
Ponte de Artéria Coronária , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Migração de Corpo Estranho/diagnóstico por imagem , Stents , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Migração de Corpo Estranho/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
Arch Dis Child Fetal Neonatal Ed ; 102(3): F251-F255, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28424358

RESUMO

OBJECTIVES: To evaluate the umbilical venous catheter (UVC) tip position by ultrasound and compare it with standard radiograph findings and to examine the catheter tip migration rates during the first week of life. DESIGN: Prospective observational study of inborn preterm infants who had an UVC placed and its position radiographically confirmed. The first ultrasound was done on UVC placement at median (IQR) age of 2 hours (1-4) and follow-up scans at a median (IQR) age of 34 hours (27-44 hours), 77 hours (70-94 hours) and 6 days (5-7 days) after insertion. Catheter tip was considered in optimum position if tip was lying in the inferior vena cava up to the right atrium opening. RESULTS: We studied 65 infants at a mean (±SD) gestational age and birth weight of 26.4 (±2.1) weeks and 808 (±289) g, respectively. Ultrasound confirmed optimum position of UVC tip in 25/65 (38.5%) infants. Majority (38/40) of the malpositioned catheters were located inside the heart with 15 reaching the left atrium. Catheter tip migration occurred in 29 of 58 infants (50%) at any time during the first week. The proportions of UVC migration were found to be 17%, 31% and 29% on subsequent ultrasound with a trend to outward movement over time. CONCLUSION: UVC tip localisation by standard radiography is very imprecise, and catheter tip migration occurs in a significant proportion of infants during first weeks of age. We suggest ultrasound as the best modality to assist localisation and follow-up of UVC tip in preterm infants.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Migração de Corpo Estranho/diagnóstico por imagem , Veias Umbilicais/diagnóstico por imagem , Peso ao Nascer , Feminino , Seguimentos , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Estudos Prospectivos , Radiografia , Ultrassonografia
10.
Am J Perinatol ; 33(6): 600-4, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26731179

RESUMO

Objective This study aims to determine the frequency that umbilical venous catheters (UVCs) and peripherally inserted central catheters (PICCs) migrate into the cardiothymic silhouette after initial verification of correct placement. Study Design This is a single-center, retrospective study in neonates in whom a PICC or UVC was placed. The frequency of catheter tip migration into the cardiothymic silhouette requiring catheter manipulation was determined radiographically at 1 and 24 hours, respectively, after insertion. Results At 1 and 24 hours, 36 and 23% of UVCs (n = 41) migrated into the cardiothymic silhouette, respectively. At 1 and 24 hours, 23 and 11% of PICCs (n = 63) migrated into the cardiothymic silhouette, respectively. Migration was not associated with birth weight, weight at insertion, or postnatal age at insertion. Conclusion UVCs and PICCs frequently migrate into the cardiothymic silhouette increase the risk for development of a pericardial effusion. Serial radiographic assessment of catheter tip location is needed to assess catheter migration within the first 24 hours of line placement.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/epidemiologia , Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Feminino , Migração de Corpo Estranho/terapia , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Masculino , Derrame Pericárdico/etiologia , Radiografia Torácica , Estudos Retrospectivos , Centros de Atenção Terciária , Fatores de Tempo , Veias Umbilicais , Wisconsin
11.
J Heart Lung Transplant ; 34(12): 1617-23, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26298062

RESUMO

BACKGROUND: Surgical positioning of the HeartMate II (HMII) left ventricular assist device assuring an unobstructed blood flow path is essential for optimal device function and hemodynamic support. We report a non-invasive radiologic assessment of HMII position after implant and long-term follow-up. METHODS: We reviewed 132 consecutive patients (age 64 ± 14 years; 86% male; 60% destination therapy) implanted with an HMII from January 2009 to December 2012 and followed for them for up to 4 years. A radiologist measured pump position, pocket depth and cannula angles using chest radiography. Changes over time were determined in 64 of these patients with pairs of radiographs immediately after implant and at an average of 2.0 ± 0.7 years of follow-up. RESULTS: The axis of the pump relative to the spine was 92 ± 10° at baseline and 94 ± 9° at 2 years (n = 64, p = 0.02), and inflow cannula angles averaged 21 ± 13° from vertical at baseline and 20 ± 12° at 2 years (p = not statistically significant). More than 90% of angle measurements showed <15° movement over the follow-up duration. There was a small but significant superior pump migration from a depth of 12.7 ± 2.7 cm to 10.4 ± 2.6 cm (p < 0.001). There were no cannula obstructions or instances of right ventricular assist device use. The 30-day operative mortality was 3.0%. Prolonged inotrope dependence occurred in 5.3% (7 of 126) of patients, and low rates of pump thrombosis of 0.018 event/patient-year (0 at 3 months) and stroke 0.074 event/patient-year were noted. CONCLUSION: Non-invasive radiographic measurements of surgical pump placement designed to avoid pump and cannula malposition demonstrate stable position with minimal pump migration.


Assuntos
Migração de Corpo Estranho/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Falha de Prótese , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Fatores de Tempo
12.
J Craniofac Surg ; 25(3): e233-5, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24777003

RESUMO

Two cases of foreign bodies that were incidentally observed on orthopantomographs are reported in this study. The foreign bodies were analyzed using an x-ray fluorescence spectrometer to identify what the migrated foreign bodies were and what migration pathways they had taken. The removed metallic foreign bodies from the maxillae of 2 patients, who were referred to the Department of Dentistry and Oral Surgery of the University of Fukui Hospital, were analyzed using an x-ray fluorescence spectrometer in the Department of Dental and Biomedical Materials Science, Nagasaki University. The major component of foreign body in patient 1 was silver, and that in case 2 was iron. On the basis of the imaging results and the patients' clinical history, the foreign bodies were considered to be caused by iatrogenic migration. Understanding the existence of foreign bodies and their migration pathway into the jaw bone can thus make clinicians more aware of such migrations and can thereby contribute to reducing iatrogenic accidents.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Migração de Corpo Estranho/diagnóstico por imagem , Achados Incidentais , Mandíbula/diagnóstico por imagem , Maxila/diagnóstico por imagem , Idoso , Corpos Estranhos/cirurgia , Migração de Corpo Estranho/cirurgia , Humanos , Doença Iatrogênica , Ferro/análise , Masculino , Mandíbula/cirurgia , Maxila/cirurgia , Pessoa de Meia-Idade , Agulhas/efeitos adversos , Radiografia Panorâmica/métodos , Prata/análise , Espectrometria por Raios X/métodos , Tomografia Computadorizada por Raios X/métodos , Extração Dentária/efeitos adversos , Extração Dentária/instrumentação
13.
Med Biol Eng Comput ; 49(8): 901-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21713516

RESUMO

Although cardiac resynchronization therapy (CRT) is an effective treatment for chronic systolic heart failure with dyssynchrony, about one-third of patients do not respond favorably. The interaction between the pacing lead and the coronary sinus (CS) branches is of paramount importance for an effective resynchronization. Minor changes in lead position overtime could interfere with CRT mechanics, without affecting even biophysical parameters or ECG morphology. Although late post-implant CS lead dislodgement rate is consistent, lead movements have been little investigated and only with bi-dimensional methods. The aim of this study was (1) to develop a method for quantifying CS lead position in the 3D domain throughout the cardiac cycle and (2) to test it by comparing the CS lead position at implant and at follow-up, using chest fluoroscopy. Method performance, its accuracy and reproducibility were qualitatively and quantitatively assessed. Intra- and inter-observer percent discordance between trajectories were also computed. The accuracy of the procedure resulted in 0.3 ± 0.1 mm and its resolution was 0.5 mm. Intra- and inter-observer discordances were 2.2 ± 1.5 and 5.5 ± 3.6 mm, respectively. The proposed method for measuring the CS lead dynamic placement in 3D space seems accurate and reproducible. Investigating CS lead 3D dynamics could provide further insights into CRT mechanics.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Seio Coronário/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Análise de Falha de Equipamento/métodos , Feminino , Fluoroscopia , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
14.
J Surg Res ; 166(1): 109-13, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19691972

RESUMO

BACKGROUND: The natural history of laparoscopically placed mesh remains uncharacterized. Mesh migration is not infrequently discovered at reoperation and implicated as a cause of hernia recurrence, and it has also been associated with more serious complications, such as enteric and bladder erosion and fistula formation. To date, there is no noninvasive method by which to reliably assess the in-vivo behavior of laparoscopically placed mesh. In this study, we devised and validated a safe and noninvasive model, utilizing computed radiography (CR), for measuring postoperative mesh migration that may be applied to the clinical setting. METHODS: The anatomical structures of the inguinal region were recreated using a skeletal male pelvic model. A sheet of commercially available surgical mesh, marked with three 5mm surgical clips at its medial and superior corners, was moved along the inguinal ligament wire for various random distances. The mesh displacement was measured from the model, and a CR film was obtained. The corresponding mesh displacement was then measured on the CR using two different calibration methods (calibration disk and clip measurement). RESULTS: A total of 60 measurements were made and recorded. There were no statistically significant differences between the true (as measured from the model) and CR-measured distances of mesh migration. In comparing the two methods, only method 1 (calibration disk) showed a tendency towards a significant difference when lateral or superior displacement was measured, but correlation remained excellent (r(2) = 0.99). All other measurements showed no significant difference and excellent correlation (r(2) > 0.96). Pearson's correlation coefficients showed no significant inter-rater variability using either of these methods. CONCLUSION: Our CR model reliably provides a noninvasive means to characterize mesh movement in the postoperative clinical setting. This should provide an instrument to facilitate future clinical evaluation of mesh migration in human trials.


Assuntos
Migração de Corpo Estranho/diagnóstico por imagem , Hérnia Inguinal/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Telas Cirúrgicas/efeitos adversos , Tomografia Computadorizada por Raios X/normas , Calibragem , Humanos , Laparoscopia/efeitos adversos , Masculino , Modelos Anatômicos , Variações Dependentes do Observador , Recidiva , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
15.
Surg Endosc ; 22(5): 1326-33, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18027044

RESUMO

BACKGROUND: Historically, esophageal fistulas, perforations, and benign and malignant strictures have been managed surgically or with the placement of permanent endoprostheses or metallic stents. Recently, a removable, self-expanding, plastic stent has become available. The authors investigated the use of this new stent at their institution. METHODS: The study reviewed all the patients who received a Polyflex stent for an esophageal indication at the authors' institution between January 2004 and October 2006. Duration of placement, complications, and treatment efficacy were recorded. RESULTS: A total of 37 stents were placed in 30 patients (14 women and 16 men) with a mean age of 68 years (range, 28-92 years). Stent placement included 7 for fistulas, 3 for perforations, 1 for an anastomotic leak, 7 for malignant strictures, and 19 for benign strictures (8 anastomotic, 1 caustic, 5 reflux, 2 radiation, and 2 autoimmune esophagitis strictures, and 1 post-Nissen gas bloat stricture). The mean follow-up period was 6 months. Stent deployment was successful for all the patients, and no complications resulted from stent placement or removal. Nine stents migrated spontaneously. Three of three perforations and three of five fistulas sealed. Only one stent was removed because of patient discomfort. One patient with a radiation stricture experienced tracheoesophageal fistulas secondary to pressure necrosis. Of 20 patients with stricture, 18 experienced improvement in their dysphagia. CONCLUSION: Self-expanding, removable plastic stents are easily and safely placed and removed from the esophagus. This has facilitated their use in the authors' institution for an increasing number of esophageal conditions. Further studies to help define their ultimate role in benign and malignant esophageal pathology are warranted.


Assuntos
Doenças do Esôfago/cirurgia , Esofagoscopia/métodos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Materiais Biocompatíveis/uso terapêutico , Remoção de Dispositivo , Doenças do Esôfago/diagnóstico por imagem , Feminino , Fluoroscopia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Poliésteres/uso terapêutico , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Silicones/uso terapêutico , Resultado do Tratamento
16.
J Endovasc Ther ; 14(5): 650-60, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17924730

RESUMO

PURPOSE: To investigate the morphological effects of suprarenal fixation of aortic stent-grafts on the renal artery ostia (RaO) by analysis of suprarenal stent wire distribution and vascular calcification across the RaO using virtual intravascular endoscopy (VIE). METHODS: Fourteen consecutive patients (11 men; mean age 75 years) from a single institution were studied following endovascular aortic aneurysm repair (EVAR) using the Zenith endograft system from September 1999 to March 2002. Imaging assessment included computed tomographic (CT) measurement of renal artery intraluminal ostial diameter and quantification and analysis of uncovered stent struts across the RaO and radiological determination of RaO calcification. Morphological changes following EVAR at 3 time points (before and within 1 week after stent-grafting, and at the most recent follow-up) were compared for each patient to determine whether suprarenal stent struts or RaO calcification affected intraluminal ostial diameter. Renal function was assessed by temporal measurements of serum creatinine concentration and creatinine clearance. RESULTS: The renal ostium was distorted to variable degrees in all cases at a mean follow-up of 41+/-6.6 months. An increase in ostial diameter was identified in most patients if the right RaO was calcified when comparing the 1-week postoperative and most recent follow-up CT images (p<0.05). There was no direct relationship between the number of stent struts crossing the RaO and the morphological/dimensional changes (p>0.05). Renal function was not significantly affected. CONCLUSION: Patients undergoing suprarenal fixation of aortic stent-grafts experienced morphological changes of the RaO to a variable extent at midterm follow-up. Although the presence of stent struts did not significantly affect dimensional changes, we observed that calcification at the renal artery ostium may influence the development of atherosclerotic effects as a direct relationship between the calcification and ostial diameter. Future studies utilizing VIE to determine the long-term safety of this technique in these particular patients requires investigation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Endoscopia/métodos , Artéria Renal/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X , Interface Usuário-Computador , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Calcinose/diagnóstico por imagem , Feminino , Seguimentos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Artéria Renal/cirurgia , Projetos de Pesquisa , Fatores de Tempo , Resultado do Tratamento
17.
Cardiovasc Radiat Med ; 3(3-4): 190-2, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12974372

RESUMO

PURPOSE: Positive remodeling and decreased neointima proliferation are among the causes for Late Stent Malapposition (LSM). It was our interest to investigate a possible relationship between dose and incidence of LSM. METHODS: Index and follow up IVUS examinations of 238 patients (152 treated with Intravascular Brachytherapy (IVBT), 86 control) enrolled in IVBT trials were reviewed to identify patients with LSM. 7.2% of patients treated with IVBT and 2.3% of patients in the control group were found to have LSM on their 6-month follow-up IVUS. Using the index IVUS study. Dose Volume Histograms (DVH) were constructed for a segment of the adventitia comprising an arc deep to the area where LSM is present at follow up. For control, two areas: an arc deep to complete apposition (Control 1) and a segment within the stent but 5 mm apart from the LSM (Control 2). Volumes were defined by IVUS images that were 1 mm apart and the media-adventitial contour was taken to be 0.5 mm thick from the border. RESULTS: DVH of 90% and 50% adventitial volume of LSM area received a significantly (p < .05) higher dose compared to both controls. Calculated are 12 LSM sites in 9 patients and 9 control sites. At all 12 sites Mean Cross Sectional Area of External Elastic Membrane (EEM CSA) was significantly larger in the LSM group at follow up compared to index (p-.001). CONCLUSIONS: DVH analysis showed a positive correlation between radiation dose to the adventitia and incidence of LSM. The myofibroblasts in the adventitia are known to be the target for irradiation. Proliferation of myofibroblasts leads to neointima formation. LSM may be due to the higher dosages delivered to 50% and 90% of the adventitia volume (LSM area) which may have led to profound neointima suppression. In turn the neointima could not compensate positive remodeling reflected by an increase in EEM CSA.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Braquiterapia/efeitos adversos , Reestenose Coronária/prevenção & controle , Estenose Coronária/patologia , Estenose Coronária/terapia , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/patologia , Complicações Pós-Operatórias , Stents/efeitos adversos , Estudos de Coortes , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/patologia , Estenose Coronária/diagnóstico por imagem , Relação Dose-Resposta à Radiação , Seguimentos , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Fatores de Tempo , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/patologia , Túnica Íntima/efeitos da radiação , Ultrassonografia de Intervenção
18.
J Arthroplasty ; 16(5): 598-606, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11503119

RESUMO

The Charnley Elite and the Exeter stems have different design concepts: The former is designed not to subside, whereas the latter is expected to subside. This radiostereometric analysis study compares the early migration of the 2 stems. For both implants, the 1st year migration was about 4 times faster than the 2nd year. The Exeter migration was predominantly distal (1 mm/y in the 1st year). It also showed slight collapse into valgus, and the head migrated slowly posteriorly (0.3 mm/y in the 1st year). In contrast, the Elite had slow distal migration (0.2 mm/y in the 1st year) and rapid posterior head migration (0.8 mm/y in the 1st year). Four Elites and no Exeters had rapid posterior head migration rates (mean 2.8 mm/y in the 1st year and 0.8 mm/y in the 2nd year). The Elite and the Exeter stems have fundamentally different early patterns of migration, which affect their long-term function; 20% of the Elites and none of the Exeters had rapid posterior head migration in the 1st year and the 2nd year and are likely to fail early. Polished, collarless, tapered designs, such as the Exeter, may be more forgiving than conventional stems designed not to subside.


Assuntos
Artroplastia de Quadril , Fêmur , Migração de Corpo Estranho/etiologia , Prótese de Quadril/efeitos adversos , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Desenho de Prótese , Falha de Prótese , Radiografia , Resultado do Tratamento
19.
Neurosurgery ; 48(5): 1066-72; discussion 1072-4, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11334273

RESUMO

OBJECTIVE: Guglielmi detachable coiling (GDC) has quickly become the most common endovascular method for the treatment of intracranial aneurysms. Although several published case series describe various authors' successful experiences or complications, few have elaborated on failed attempts. We examined our experience with GDC, and we analyzed all failed attempts at coiling. METHODS: Patients who underwent endovascular procedures from September 1995 through July 1999 were identified using endovascular case logs and billing records. Patient charts were then reviewed retrospectively for failed attempts at GDC. A treatment failure was defined as an inability to place coils into an aneurysm, a GDC procedure-related complication resulting in death, or an acute rehemorrhage from a coiled aneurysm that indicated a failure of coils to prevent rerupture. Thromboembolic events and other nonfatal sources of morbidity that did not preclude coiling of the aneurysm were analyzed only to the extent that they prevented successful coiling of the aneurysm. RESULTS: From September 1995 to June 1999, 241 patients underwent GDC embolizations or attempts. In these patients, 35 procedures were unsuccessful, including 7 deaths from intraoperative or postoperative aneurysmal rerupture. Sixteen aneurysms could not be microcatheterized, nine of which were anterior communicating artery aneurysms. Coils from 13 wide-necked aneurysms (average fundus-to-neck ratio, <2) prolapsed into the parent vessel. Three procedures were abandoned when the aneurysms were found to have normal branches filling from the dome, and three additional procedures were abandoned for technical reasons. Five deaths resulted from intraoperative aneurysm rupture, and two patients died postoperatively from rerupture. CONCLUSION: The number of successful coiling procedures has increased with experience and improved technology. The procedure still involves risks, however, primarily for patients with subarachnoid hemorrhage.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/etiologia , Aneurisma Roto/mortalidade , Angiografia Cerebral , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Embolização Terapêutica/mortalidade , Feminino , Migração de Corpo Estranho/complicações , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Prevenção Secundária , Falha de Tratamento