Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 541
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(11)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38894259

RESUMO

The optimal indoor environment is associated with comfortable temperatures along with favorable indoor air quality. One of the air pollutants, particulate matter (PM), is potentially harmful to animals and humans. Most farms have monitoring systems to identify other hazardous gases rather than PM due to the sensor cost. In recent decades, the application of environmental monitoring systems based on Internet of Things (IoT) devices that incorporate low-cost sensors has elevated extensively. The current study develops a low-cost air quality monitoring system for swine buildings based on Raspberry Pi single-board computers along with a sensor array. The system collects data using 11 types of environmental variables along with temperature, humidity, CO2, light, pressure, and different types of gases, namely PM1, PM2.5, and PM10. The system is designed with a central web server that provides real-time data visualization and data availability through the Internet. It was tested in actual pig barns to ensure stability and functionality. In addition, there was a collocation test conducted by placing the system in two different pig barns to validate the sensor data. The Wilcoxon rank sum test demonstrates that there are no significant differences between the two sensor datasets, as all variables have a p-value greater than 0.05. However, except for carbon monoxide (CO), none of the variables exhibit correlation exceeding 0.5 with PM concentrations. Overall, a scalable, portable, non-complex, low-cost air quality monitoring system was successfully developed within a cost of USD 94.


Assuntos
Poluição do Ar em Ambientes Fechados , Monitoramento Ambiental , Material Particulado , Poluição do Ar em Ambientes Fechados/análise , Animais , Suínos , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Material Particulado/análise , Poluentes Atmosféricos/análise , Humanos , Monóxido de Carbono/análise , Dióxido de Carbono/análise
2.
Artigo em Inglês | MEDLINE | ID: mdl-38791837

RESUMO

Air pollution poses a significant health hazard in urban areas across the globe, with India being one of the most affected countries. This paper presents environmental monitoring study conducted in Jodhpur, Rajasthan, India, to assess air quality in diverse urban environments. The study involved continuous indoor and outdoor air quality monitoring, focusing on particulate matter (PM2.5) levels, bioaerosols, and associated meteorological parameters. Laser sensor-based low-cost air quality monitors were utilized to monitor air quality and Anderson 6-stage Cascade Impactor & Petri Dish methods for bioaerosol monitoring. The study revealed that PM2.5 levels were consistently high throughout the year, highlighting the severity of air pollution in the region. Notably, indoor PM2.5 levels were often higher than outdoor levels, challenging the common notion of staying indoors during peak pollution. The study explored the spatial and temporal diversity of air pollution across various land-use patterns within the city, emphasizing the need for tailored interventions in different urban areas. Additionally, bioaerosol assessments unveiled the presence of pathogenic organisms in indoor and outdoor environments, posing health risks to residents. These findings underscore the importance of addressing particulate matter and bioaerosols in air quality management strategies. Despite the study's valuable insights, limitations, such as using low-cost air quality sensors and the need for long-term data collection, are acknowledged. Nevertheless, this research contributes to a better understanding of urban air quality dynamics and the importance of public awareness in mitigating the adverse effects of air pollution. In conclusion, this study underscores the urgent need for effective air quality management strategies in urban areas. The findings provide valuable insights for policymakers and researchers striving to address air pollution in rapidly urbanizing regions.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Cidades , Monitoramento Ambiental , Material Particulado , Índia , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Material Particulado/análise , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Poluição do Ar em Ambientes Fechados/análise , Aerossóis/análise
3.
J Occup Environ Hyg ; 21(5): 311-318, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38560887

RESUMO

Improving asthma outcomes for underserved populations can be addressed through interventions to improve indoor air quality (IAQ). New protocol for measuring IAQ and health outcomes are imperative given advances in IAQ monitoring technology and challenges in conducting intervention research in homes. In this pilot study HEPA air purifiers and HEPA vacuum cleaners were provided to five homes with children with asthma. For 6 weeks, eight common components of air quality were measured using a low-cost multi-channel air quality monitoring device, with data conveyed directly from participant homes via Wi-Fi connection. In conjunction with periodic surveys on asthma control, impact of asthma on quality of life and intervention compliance, outcomes compared IAQ, home characteristics, and asthma-related measures. This pilot study demonstrates the feasibility of a protocol to evaluate a dual component intervention to improve IAQ in homes, as measured with a low-cost air quality monitoring device.


Assuntos
Poluição do Ar em Ambientes Fechados , Asma , Monitoramento Ambiental , Estudos de Viabilidade , Humanos , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Projetos Piloto , Criança , Habitação , Feminino , Masculino , Qualidade de Vida , Filtros de Ar
4.
Braz. J. Pharm. Sci. (Online) ; 60: e23664, 2024. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1533992

RESUMO

Abstract For places where non-sterile drug production occurs, regulatory bodies recommend monitoring of the environmental bioburden. This procedure provides information regarding possible microbiological risks to which the products may be exposed, so that subsequent action measures may be implemented. The aim of the present work was to quantify and characterize the microorganisms present in Grade D (ISO 8) cleanrooms of a Brazilian pharmaceutical industry, identifying any possible seasonal climatic influences on these environments. Sampling was performed by surface and air monitoring, over 12 months during the year 2019, in rooms that were in operation. For both sampling methods, no statistically significant differences in bacteria and fungi counts were found between months or seasonal periods. Microorganisms that presented higher incidence included Staphylococcus epidermidis (15%) and Micrococcus spp. (13%), common to the human microbiota, and the fungi Cladosporium sp. (23%) and Penicillium sp. (21%), typical of the external environment. The results showed that microbial contamination in the Grade D cleanrooms was within the permissible maximum levels and remained similar throughout the year. Microbiological quality control in the clean areas of the pharmaceutical industry investigated was considered effective, with regular maintenance being necessary to keep bioburden levels controlled.


Assuntos
Bactérias/classificação , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Indústria Farmacêutica/instrumentação , Poluição Ambiental/prevenção & controle , Microbiota/imunologia , Fungos/classificação
5.
Arq. ciências saúde UNIPAR ; 27(3): 1173-1182, 2023.
Artigo em Português | LILACS | ID: biblio-1425453

RESUMO

Objetivo: descrever o processo de condução de um caso com manifestação oftálmica pela mpox, destacando o trabalho da enfermagem na prevenção de complicações da doença. Método: relato de experiência da condução de um caso de mpox ocorrido em setembro de 2022 com manifestação oftálmica. Resultados: a pronta identificação da complicação oftálmica, com a presença de conjuntivite e edema palpebral, apresentada por um paciente com suspeita de mpox pela equipe de enfermagem da vigilância epidemiológica durante as ações de monitoramento, e o envolvimento da equipe com outras equipes de diversos níveis da assistência à saúde permitiram a instituição precoce do tratamento com antiviral recomendado pelo Ministério da Saúde, o que contribuiu para um melhor desfecho. Conclusão: é importante que se dissemine o conhecimento sobre as manifestações oftálmicas associadas à mpox para que a equipe de enfermagem, que atua nos diversos níveis de atenção à saúde, esteja atenta para implementar, de forma precoce, medidas de prevenção, diagnóstico e tratamento adequados.


Objective: to describe the process of conducting a case with ophthalmic manifestation by mpox, highlighting the work of nursing in preventing complications of the disease. Method: experience report of managing a case of mpox that occurred in September 2022 with ophthalmic manifestation. Results: the prompt identification of the ophthalmic complication, with the presence of conjunctivitis and eyelid edema, presented by a patient with suspected mpox by the epidemiological surveillance nursing team during monitoring actions and the team's involvement with other teams from different levels of the health care allowed the early initiation of antiviral treatment recommended by the Ministry of Health, which contributed to a better outcome. Conclusion: it is important to disseminate knowledge about ophthalmic manifestations associated with mpox for the nursing team that works at different levels of health care to be attentive to implement preventive measures, diagnosis and adequate and early treatment.


Objetivo: describir el proceso de manejo de un caso con manifestación of- talmológica por mpox, destacando la labor de enfermería en la prevención de complica- ciones de la enfermedad. Material y método: relato de experiencia de manejo de un caso de mpox ocurrido en septiembre de 2022 con manifestación oftálmica. Resultados: la rápida identificación de la complicación oftálmica, con la presencia de conjuntivitis y edema de párpados, presentada por un paciente con sospecha de mpox por el equipo de enfermería de vigilancia epidemiológica durante las acciones de monitoreo y la partici- pación del equipo con otros equipos de diferentes niveles de la asistencia sanitaria per- mitió el inicio precoz del tratamiento antiviral recomendado por el Ministerio de Salud, lo que contribuyó a un mejor resultado. Conclusión: es importante difundir el conoci- miento sobre las manifestaciones oftálmicas asociadas a la viruela del mono para que el equipo de enfermería que actúa en los diferentes niveles de atención a la salud esté atento a implementar medidas preventivas, diagnósticas y de tratamiento adecuado y precoz.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Vigilância Sanitária , Mpox/diagnóstico , Mpox/prevenção & controle , Mpox/terapia , Manifestações Oculares , Antivirais , Monitoramento Ambiental/instrumentação , Enfermagem , Conjuntivite/diagnóstico , Conjuntivite/prevenção & controle , Conjuntivite/terapia , Relatos de Casos como Assunto , Pesquisa sobre Serviços de Saúde
6.
PLoS One ; 17(1): e0262721, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35045110

RESUMO

Upside-down jellyfish (Cassiopea sp.) are mostly sedentary, benthic jellyfish that have invaded estuarine ecosystems around the world. Monitoring the spread of this invasive jellyfish must contend with high spatial and temporal variability in abundance of individuals, especially around their invasion front. Here, we evaluated the utility of drones to survey invasive Cassiopea in a coastal lake on the east coast of Australia. To assess the efficacy of a drone-based methodology, we compared the densities and counts of Cassiopea from drone observations to conventional boat-based observations and evaluated cost and time efficiency of these methods. We showed that there was no significant difference in Cassiopea density measured by drones compared to boat-based methods along the same transects. However, abundance estimates of Cassiopea derived from scaling-up transect densities were over-inflated by 319% for drones and 178% for boats, compared to drone-based counts of the whole site. Although conventional boat-based survey techniques were cost-efficient in the short-term, we recommend doing whole-of-site counts using drones. This is because it provides a time-saving and precise technique for long-term monitoring of the spatio-temporally dynamic invasion front of Cassiopea in coastal lakes and other sheltered marine habitats with relatively clear water.


Assuntos
Comportamento Animal/fisiologia , Monitoramento Ambiental/métodos , Dispositivos Aéreos não Tripulados/ética , Animais , Animais Selvagens , Austrália , Ecossistema , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Espécies Introduzidas/tendências , Lagos , Cifozoários/metabolismo , Água
7.
Braz. J. Pharm. Sci. (Online) ; 58: e191051, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1394051

RESUMO

Abstract The present work reports the implementation of the Hazard Analysis Critical Control Point (HACCP) methodology to analyze the water purification system of a pharmaceutical site, in order to assure the system quality and prevent failures. As a matter of fact, the use of HACCP for development and implementation of Quality Risk Management (QRM) is not usual in pharmaceutical plants and it is applied here to improve the performance of the water purification system of a polymerization pilot plant used to manufacture pharmaceutical grade polymer microparticles. Critical Control Points (CCP) were determined with the aid of a decision tree and questions were made to characterize whether identified hazards constitute actual CCPs and should be monitored. When deviations were detected, corrective actions were performed and action plans were used for following-up and implementation of corrective actions. Finally, microbiological and physicochemical parameters were analyzed and the obtained results were regarded as appropriate. Therefore, it is shown that HACCP constitutes an effective tool for identification of hazards, establishment of corrective actions and monitoring of the critical control points that impact the process and the quality of the final pharmaceutical product most significantly.


Assuntos
Gestão de Riscos/classificação , Purificação da Água/instrumentação , Análise de Perigos e Pontos Críticos de Controle/métodos , Monitoramento Ambiental/instrumentação , Gestão da Qualidade Total/métodos , Indústria Farmacêutica/classificação , Metodologia como Assunto , Relatório de Pesquisa
8.
Proc Natl Acad Sci U S A ; 118(37)2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34493674

RESUMO

Disparity in air pollution exposure arises from variation at multiple spatial scales: along urban-to-rural gradients, between individual cities within a metropolitan region, within individual neighborhoods, and between city blocks. Here, we improve on existing capabilities to systematically compare urban variation at several scales, from hyperlocal (<100 m) to regional (>10 km), and to assess consequences for outdoor air pollution experienced by residents of different races and ethnicities, by creating a set of uniquely extensive and high-resolution observations of spatially variable pollutants: NO, NO2, black carbon (BC), and ultrafine particles (UFP). We conducted full-coverage monitoring of a wide sample of urban and suburban neighborhoods (93 km2 and 450,000 residents) in four counties of the San Francisco Bay Area using Google Street View cars equipped with the Aclima mobile platform. Comparing scales of variation across the sampled population, greater differences arise from localized pollution gradients for BC and NO (pollutants dominated by primary sources) and from regional gradients for UFP and NO2 (pollutants dominated by secondary contributions). Median concentrations of UFP, NO, and NO2 are, for Hispanic and Black populations, 8 to 30% higher than the population average; for White populations, average exposures to these pollutants are 9 to 14% lower than the population average. Systematic racial/ethnic disparities are influenced by regional concentration gradients due to sharp contrasts in demographic composition among cities and urban districts, while within-group extremes arise from local peaks. Our results illustrate how detailed and extensive fine-scale pollution observations can add new insights about differences and disparities in air pollution exposures at the population scale.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Etnicidade/estatística & dados numéricos , Disparidades nos Níveis de Saúde , Aplicativos Móveis/estatística & dados numéricos , Planejamento Social , Reforma Urbana , Cidades , Monitoramento Ambiental/instrumentação , Humanos
9.
Proc Natl Acad Sci U S A ; 118(27)2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-34155096

RESUMO

Extreme air quality episodes represent a major threat to human health worldwide but are highly dynamic and exceedingly challenging to monitor. The 2018 Kilauea Lower East Rift Zone eruption (May to August 2018) blanketed much of Hawai'i Island in "vog" (volcanic smog), a mixture of primary volcanic sulfur dioxide (SO2) gas and secondary particulate matter (PM). This episode was captured by several monitoring platforms, including a low-cost sensor (LCS) network consisting of 30 nodes designed and deployed specifically to monitor PM and SO2 during the event. Downwind of the eruption, network stations measured peak hourly PM2.5 and SO2 concentrations that exceeded 75 µg m-3 and 1,200 parts per billion (ppb), respectively. The LCS network's high spatial density enabled highly granular estimates of human exposure to both pollutants during the eruption, which was not possible using preexisting air quality measurements. Because of overlaps in population distribution and plume dynamics, a much larger proportion of the island's population was exposed to elevated levels of fine PM than to SO2 Additionally, the spatially distributed network was able to resolve the volcanic plume's chemical evolution downwind of the eruption. Measurements find a mean SO2 conversion time of ∼36 h, demonstrating the ability of distributed LCS networks to observe reaction kinetics and quantify chemical transformations of air pollutants in a real-world setting. This work also highlights the utility of LCS networks for emergency response during extreme episodes to complement existing air quality monitoring approaches.


Assuntos
Poluição do Ar/análise , Custos e Análise de Custo , Exposição Ambiental/análise , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Poluição Ambiental/análise , Erupções Vulcânicas , Material Particulado/análise , Comunicações Via Satélite , Dióxido de Enxofre/análise
10.
Ecotoxicol Environ Saf ; 211: 111958, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33503545

RESUMO

BACKGROUND: Accurate individual exposure assessment is crucial for evaluating the health effects of particulate matter (PM). Various portable monitors built upon low-cost optical sensors have emerged. However, the main challenge for their application is to guarantee accuracy of measurements. OBJECTIVE: To assess the performance of a newly developed PM sensor, and to develop methods for post-hoc data calibration to optimize its data quality. METHOD: We conducted a series of laboratory experiments and field evaluations to quantify the reproducibility within Plantower PM sensors 7003 (PMS 7003) and the consistency between sensors and two established PM2.5 measurement methods [tapered element oscillating microbalances (TEOM) and gravimetric method (GM)]. Post-hoc data calibration methods for sensors were based on a multiple linear regression model (MLRM) and a random forest model (RFM). Ratios of raw and calibrated readings over the data of reference methods were calculated to examine the improvement after calibration. RESULTS: Strong correlations (≥0.82) and relatively small relative standard deviations (16-21%) between sensors were found during the laboratory and the field sampling. Compared with the reference methods, moderate to strong coefficients of determination (0.56-0.83) were observed; however, significant deviations were presented. After calibration, the ratios of PMS measurements over that of two reference methods both became convergent. CONCLUSIONS: Our study validated low-cost optical PM sensors under a wide range of PM2.5 concentrations (8-167 µg/m3). Our findings indicated potential applicability of PM sensors in PM2.5 exposure assessment, and confirmed a need of calibration. Linear calibration methods may be sufficient for ambient monitoring using TEOM as a reference, while nonlinear calibration methods may be more appropriate for indoor monitoring using GM as a reference.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Calibragem , Monitoramento Ambiental/métodos , Humanos , Laboratórios , Modelos Lineares , Material Particulado/análise , Reprodutibilidade dos Testes
11.
Environ Sci Pollut Res Int ; 28(42): 59430-59438, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33479872

RESUMO

The importance of studying the atmospheric pollution due to its effects on human health and other ecosystems, the inexistence of national production of equipment for air sample collection, and the high cost of the imported equipment (especially in developing countries) led the authors of the present work to construct a low-cost Gent type sampler. The construction of the sampler was carried out by combining low-cost materials with good mechanical strength (such as nylon 6.0), hydraulic piping PVC, and the use of a 3D printer. The innovation of the present work is the employment of a 3D printer using ABS polymer to create the grids that cannot be machined. In addition to the sampler, the system is composed of a vacuum pump, a gas meter, and a rotameter. The total cost of the sampling system amounted at about 1200 USD, and the cost of the manufactured Gent type sampler did not reach 100 USD. The results obtained while using this set for sampling atmospheric aerosol for a period of 11 months were compared with the mass concentration of PM10 obtained from the official environmental company, CETESB of São Paulo State, Brazil, showing good correlation with those from CETESB - which confirmed its effectiveness and suitability for use. The low cost, easy operation, and versatility of the built Gent type sampler enable its use for scientific and academic purposes. The equipment can be useful in environmental monitoring networks, in low-income regions, and as an instrument for environmental education used in universities.


Assuntos
Aerossóis , Monitoramento Ambiental , Aerossóis/análise , Brasil , Monitoramento Ambiental/instrumentação , Tamanho da Partícula
12.
Anal Chem ; 93(4): 1880-1888, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33430590

RESUMO

This Feature summarizes recent works in paper-based potentiometry and voltammetry in heavy metal determination. Interactions of paper substrates with heavy metals, influence on the sensing response, and modification methods applied to paper substrates to improve the performance of recently developed electrochemical sensors are discussed. Since the rekindling of interest in paper-based analytical devices, methodologies and electrode designs for heavy metal determinations are highlighted. Promising aspects of the use of these sensors for samples containing solids and the increased versatility of the use of paper in analytics offers the possibility of increased acceptance of these low-cost platforms.


Assuntos
Técnicas Eletroquímicas/métodos , Metais Pesados/química , Papel , Técnicas Eletroquímicas/economia , Técnicas Eletroquímicas/instrumentação , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos
13.
Indoor Air ; 31(3): 755-768, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33047373

RESUMO

The intensity, frequency, duration, and contribution of distinct PM2.5 sources in Asian households have seldom been assessed; these are evaluated in this work with concurrent personal, indoor, and outdoor PM2.5 and PM1 monitoring using novel low-cost sensing (LCS) devices, AS-LUNG. GRIMM-comparable observations were acquired by the corrected AS-LUNG readings, with R2 up to 0.998. Twenty-six non-smoking healthy adults were recruited in Taiwan in 2018 for 7-day personal, home indoor, and home outdoor PM monitoring. The results showed 5-min PM2.5 and PM1 exposures of 11.2 ± 10.9 and 10.5 ± 9.8 µg/m3 , respectively. Cooking occurred most frequently; cooking with and without solid fuel contributed to high PM2.5 increments of 76.5 and 183.8 µg/m3 (1 min), respectively. Incense burning had the highest mean PM2.5 indoor/outdoor (1.44 ± 1.44) ratios at home and on average the highest 5-min PM2.5 increments (15.0 µg/m3 ) to indoor levels, among all single sources. Certain events accounted for 14.0%-39.6% of subjects' daily exposures. With the high resolution of AS-LUNG data and detailed time-activity diaries, the impacts of sources and ventilations were assessed in detail.


Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Exposição Ambiental/estatística & dados numéricos , Monitoramento Ambiental/instrumentação , Material Particulado , Adulto , Poluentes Atmosféricos , Culinária , Monitoramento Ambiental/métodos , Humanos , Tamanho da Partícula , Estações do Ano , Taiwan , Ventilação
14.
Sensors (Basel) ; 20(24)2020 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-33353048

RESUMO

This study shows the results of air monitoring in high- and low-occupancy rooms using two combinations of sensors, AeroTrak8220(TSI)/OPC-N3 (AlphaSense, Great Notley, UK) and OPC-N3/PMS5003 (Plantower, Beijing, China), respectively. The tests were conducted in a flat in Warsaw during the restrictions imposed due to the COVID-19 lockdown. The results showed that OPC-N3 underestimates the PN (particle number concentration) by about 2-3 times compared to the AeroTrak8220. Subsequently, the OPC-N3 was compared with another low-cost sensor, the PMS5003. Both devices showed similar efficiency in PN estimation, whereas PM (particulate matter) concentration estimation differed significantly. Moreover, the relationship among the PM1-PM2.5-PM10 readings obtained with the PMS5003 appeared improbably linear regarding the natural indoor conditions. The correlation of PM concentrations obtained with the PMS5003 suggests an oversimplified calculation method of PM. The studies also demonstrated that PM1, PM2.5, and PM10 concentrations in the high- to low-occupancy rooms were about 3, 2, and 1.5 times, respectively. On the other hand, the use of an air purifier considerably reduced the PM concentrations to similar levels in both rooms. All the sensors showed that frying and toast-making were the major sources of particulate matter, about 10 times higher compared to average levels. Considerably lower particle levels were measured in the low-occupancy room.


Assuntos
Poluentes Atmosféricos/análise , Poluentes Atmosféricos/química , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Monitoramento Ambiental/instrumentação , Material Particulado/análise , Material Particulado/química , COVID-19 , Controle de Doenças Transmissíveis/instrumentação , Monitoramento Ambiental/métodos , Humanos , Tamanho da Partícula , SARS-CoV-2/patogenicidade
15.
J UOEH ; 42(4): 307-315, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33268607

RESUMO

Assessment of personal exposure to particulate matter with an aerodynamic diameter less than or 2.5 µm (PM2.5) is necessary to study the association between PM exposure and health risk. Development of a personal PM2.5 sensor or device is required for the evaluation of individual exposure level. In this study, we aimed to develop a small-sized, lightweight sensor with a global positioning system (GPS) attached that can measure PM2.5 and PM10 every second to assess continuous personal exposure levels. The participants in this study were apparently healthy housewives (n = 15) and university female teaching staff (n = 15) who live in a high PM2.5 area, Yangon, Myanmar. The average PM2.5 exposure levels during 24 h were 16.1 ± 10.0 µg/m3 in the housewives and 15.8 ± 4.0 µg/m3 in the university female teaching staff. The university female teaching staff showed high exposure concentrations during commuting hours, and had stable, relatively low concentrations at work, whereas the housewives showed short-term high exposure peaks due to differences in their lifestyles. This is the first study to show that a GPS-attached standalone PM2.5 and PM10 Sensor [PRO] can be successfully used for mobile sensing, easy use, continuous measurement, and rapid data analysis.


Assuntos
Exposição Ambiental/análise , Monitoramento Ambiental/instrumentação , Sistemas de Informação Geográfica/instrumentação , Material Particulado/análise , Adulto , Feminino , Humanos , Mianmar , Tamanho da Partícula , Adulto Jovem
16.
Artigo em Inglês | MEDLINE | ID: mdl-33228125

RESUMO

(1) Background: Small, lightweight, low-cost optical particulate matter (PM) monitors are becoming popular in the field of occupational exposure monitoring, because these devices allow for real-time static measurements to be collected at multiple locations throughout a work site as well as being used as wearables providing personal exposure estimates. Prior to deployment, devices should be evaluated to optimize and quantify measurement accuracy. However, this can turn out to be difficult, as no standardized methods are yet available and different deployments may require different evaluation procedures. To gain insight in the relevance of different variables that may affect the monitor readings, six PM monitors were selected based on current availability and evaluated in the laboratory; (2) Methods: Existing strategies that were judged appropriate for the evaluation of PM monitors were reviewed and seven evaluation variables were selected, namely the type of dust, within- and between-device variations, nature of the power supply, temperature, relative humidity, and exposure pattern (peak and constant). Each variable was tested and analyzed individually and, if found to affect the readings significantly, included in a final correction model specific to each monitor. Finally, the accuracy for each monitor after correction was calculated; (3) Results: The reference materials and exposure patterns were found to be main factors needing correction for most monitors. One PM monitor was found to be sufficiently accurate at concentrations up to 2000 µg/m3 PM2.5, with other monitors appropriate at lower concentrations. The average accuracy increased by up to three-fold compared to when the correction model did not include evaluation variables; (4) Conclusions: Laboratory evaluation and readings correction can greatly increase the accuracy of PM monitors and set boundaries for appropriate use. However, this requires identifying the relevant evaluation variables, which are heavily reliant on how the monitors are used in the workplace. This, together with the lack of current consensus on standardized procedures, shows the need for harmonized PM monitor evaluation methods for occupational exposure monitoring.


Assuntos
Poluentes Atmosféricos , Monitoramento Ambiental , Exposição Ocupacional , Material Particulado , Poluentes Atmosféricos/análise , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Humanos , Exposição Ocupacional/prevenção & controle , Material Particulado/análise
17.
Artigo em Inglês | MEDLINE | ID: mdl-33187161

RESUMO

Environmental contamination affects human health and reduces the quality of life. Therefore, the monitoring of water and air quality is important, ensuring that all areas are acquiescent with the current legislation. Colorimetric sensors deliver quick, naked-eye detection, low-cost, and adequate determination of environmental analytes. In particular, disposable sensors are cheap and easy-to-use devices for single-shot measurements. Due to increasing requests for in situ analysis or resource-limited zones, disposable sensors' development has increased. This review provides a brief insight into low-cost and disposable colorimetric sensors currently used for environmental analysis. The advantages and disadvantages of different colorimetric devices for environmental analysis are discussed.


Assuntos
Colorimetria , Monitoramento Ambiental , Poluentes Ambientais , Poluição do Ar/análise , Colorimetria/economia , Colorimetria/normas , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Poluentes Ambientais/análise
18.
Artigo em Inglês | MEDLINE | ID: mdl-33023037

RESUMO

Ambient air pollution in urban cities in sub-Saharan Africa (SSA) is an important public health problem with models and limited monitoring data indicating high concentrations of pollutants such as fine particulate matter (PM2.5). On most global air quality index maps, however, information about ambient pollution from SSA is scarce. We evaluated the feasibility and practicality of longitudinal measurements of ambient PM2.5 using low-cost air quality sensors (Purple Air-II-SD) across thirteen locations in seven countries in SSA. Devices were used to gather data over a 30-day period with the aim of assessing the efficiency of its data recovery rate and identifying challenges experienced by users in each location. The median data recovery rate was 94% (range: 72% to 100%). The mean 24 h concentration measured across all sites was 38 µg/m3 with the highest PM2.5 period average concentration of 91 µg/m3 measured in Kampala, Uganda and lowest concentrations of 15 µg/m3 measured in Faraja, The Gambia. Kampala in Uganda and Nnewi in Nigeria recorded the longest periods with concentrations >250µg/m3. Power outages, SD memory card issues, internet connectivity problems and device safety concerns were important challenges experienced when using Purple Air-II-SD sensors. Despite some operational challenges, this study demonstrated that it is reasonably practicable and feasible to establish a network of low-cost devices to provide data on local PM2.5 concentrations in SSA countries. Such data are crucially needed to raise public, societal and policymaker awareness about air pollution across SSA.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/estatística & dados numéricos , Monitoramento Ambiental/métodos , Material Particulado/análise , Poluição do Ar/análise , Benin , Camarões , Cidades , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Estudos de Viabilidade , Gâmbia , Quênia , Nigéria , Projetos Piloto , Uganda
19.
Biosens Bioelectron ; 170: 112656, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33010706

RESUMO

Point-of-care risk assessment (PCRA) for airborne viruses requires a system that can enrich low-concentration airborne viruses dispersed in field environments into a small volume of liquid. In this study, airborne virus particles were collected to a degree above the limit of detection (LOD) for a real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR). This study employed an electrostatic air sampler to capture aerosolized test viruses (human coronavirus 229E (HCoV-229E), influenza A virus subtype H1N1 (A/H1N1), and influenza A virus subtype H3N2 (A/H3N2)) in a continuously flowing liquid (aerosol-to-hydrosol (ATH) enrichment) and a concanavalin A (ConA)-coated magnetic particles (CMPs)-installed fluidic channel for simultaneous hydrosol-to-hydrosol (HTH) enrichment. The air sampler's ATH enrichment capacity (EC) was evaluated using the aerosol counting method. In contrast, the HTH EC for the ATH-collected sample was evaluated using transmission-electron-microscopy (TEM)-based image analysis and real-time qRT-PCR assay. For example, the ATH EC for HCoV-229E was up to 67,000, resulting in a viral concentration of 0.08 PFU/mL (in a liquid sample) for a viral epidemic scenario of 1.2 PFU/m3 (in air). The real-time qRT-PCR assay result for this liquid sample was "non-detectable" however, subsequent HTH enrichment for 10 min caused the "non-detectable" sample to become "detectable" (cycle threshold (CT) value of 33.8 ± 0.06).


Assuntos
Técnicas Biossensoriais/instrumentação , Coronavirus Humano 229E/isolamento & purificação , Infecções por Coronavirus/virologia , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Vírus da Influenza A Subtipo H3N2/isolamento & purificação , Influenza Humana/virologia , Aerossóis/análise , Microbiologia do Ar , Técnicas Biossensoriais/economia , Coronavirus Humano 229E/genética , Monitoramento Ambiental/economia , Monitoramento Ambiental/instrumentação , Desenho de Equipamento , Humanos , Vírus da Influenza A Subtipo H1N1/genética , Vírus da Influenza A Subtipo H3N2/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/instrumentação , Fatores de Tempo
20.
J Occup Environ Hyg ; 17(10): 495-503, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32776824

RESUMO

The Internet of Things (IoT) explores new perspectives and possible improvements in risk assessment practices and shows potential to measure long-term and real-time occupational exposure. This may be of value when monitoring gases with short-term maximum levels and for time-weighted average (TWA) concentrations used in standard measuring practices. A functional embedded system was designed using low-cost carbon monoxide (CO) electrochemical sensors and long-range-wide-area-network radio communication technology (LoRaWAN) was used to enable internet connectivity. This system was utilized to monitor gas levels continuously in the working atmosphere of an incineration plant over a 2-month period. The results show that stable and long-term continuous data transfer was enabled by LoRaWAN, which proved useful for detecting rapid changes in gas levels. However, it was observed that raw data from the low-cost sensors did not meet the NIOSH accuracy criteria of ± 25% of the estimated true concentration based on field data from a co-located gas detector that met the NIOSH accuracy criteria. The new IoT technologies and CO sensor networks shows potential for remote monitoring of exposure in order to: (1) detect rapid changes in CO and other possible hazardous airborne gases; and (2) show the dynamic range of real-time data that may be hazardous for workers in the sampled areas. While the IoT low-cost sensors appear to be useful as a sentinel for monitoring hazardous atmospheres containing CO, the more useful finding may be showing real-time changes and the dynamic range of exposures, thus shedding light on the transient and toxic nature of airborne hazards. More importantly, the low-cost CO sensors are not a clear substitute for the more costly real-time gas detectors that perform within the NIOSH accuracy criteria.


Assuntos
Monóxido de Carbono/análise , Monitoramento Ambiental/métodos , Internet das Coisas , Exposição Ocupacional/análise , Poluentes Atmosféricos/análise , Monitoramento Ambiental/instrumentação , Incineração , Medição de Risco/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA