Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Matern Fetal Neonatal Med ; 33(12): 2116-2121, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30835578

RESUMO

Purpose: Third trimester maternal perception of fetal movements is often used to assess fetal well-being. However, its true clinical value is unknown, primarily because of the variability in subjective quantification. The actograph, a technology available on most cardiotocograph machines, quantifies movements, but has never previously been investigated in relation to fetal health and existing monitoring devices. The objective of this study was to quantify actograph output in healthy third trimester pregnancies and investigate this in relation to other methods of assessing fetal well-being.Methods: Forty-two women between 24 and 34 weeks of gestation underwent ultrasound scan followed by a computerized cardiotocograph (CTG). Post capture analysis of the actograph recording was performed and expressed as a percentage of activity over time. The actograph output results were analyzed in relation to Doppler, ultrasound and CTG findings expressed as z-score normalized for gestation.Results: There was a significant association between actograph output recording and estimated fetal weight Z-score (R = 0.546, p ≤ .005). This activity was not related to estimated fetal weight. Increased actograph activity was negatively correlated with umbilical artery pulsatility index Z-score (R = -0.306, p = .049) and middle cerebral artery pulsatility index Z-score (R = -0.390, p = .011).Conclusion: Fetal movements assessed by the actograph are associated both with fetal size in relation to gestation and fetoplacental Doppler parameters. It is not the case that larger babies move more, however, as the relationship with actograph output related only to estimated fetal weight z-score. These findings suggest a plausible link between the frequency of fetal movements and established markers of fetal health.RATIONALEThe objective of this study was to quantify actograph output in healthy third trimester pregnancies and investigate this in relation to other methods of assessing fetal well-being. This is a widely available method of assessing fetal movements objectively, which has been shown to be an important marker of fetal health. This research is novel in the fact that actograph has never been truly investigated in relation to fetal well-being, despite being available on most cardiotocograph (CTG) machines.Our results show that fetal movements assessed by the actograph are associated both with fetal size in relation to gestation and fetoplacental Doppler parameters. If this proves to be true, smaller babies that move less maybe at particular perinatal risk.


Assuntos
Actigrafia/instrumentação , Cardiotocografia/métodos , Movimento Fetal/fisiologia , Adulto , Feminino , Peso Fetal , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/embriologia , Gravidez , Terceiro Trimestre da Gravidez , Fluxo Pulsátil , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem
2.
PLoS One ; 13(11): e0206533, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30395584

RESUMO

OBJECTIVE: To assess the value of in utero placental assessment in predicting adverse pregnancy outcome after reported reduced fetal movements (RFM). METHOD: A non-interventional prospective cohort study of women (N = 300) with subjective RFM at ≥28 weeks' gestation in singleton non-anomalous pregnancies at a UK tertiary maternity hospital. Clinical, sonographic (fetal weight, placental size and maternal, fetal and placental arterial Doppler) and biochemical (maternal serum hCG, hPL, progesterone, PlGF and sFlt-1) assessment was conducted. Multiple logistic regression identified combinations of measurements (models) most predictive of adverse pregnancy outcome (perinatal mortality, birth weight <10th centile, five minute Apgar score <7, umbilical arterial pH <7.1 or base excess <-10, neonatal intensive care admission). Models were compared by test performance characteristics (ROC curve, sensitivity, specificity, positive/negative predictive value, positive/negative likelihood ratios) against baseline care (estimated fetal weight centile, amniotic fluid index and gestation at presentation). RESULTS: 61 (20.6%) pregnancies ended in adverse outcome. Models incorporating PlGF/sFlt-1 ratio and umbilical artery free loop Doppler impedance demonstrated modest improvement in ROC area for adverse outcome (baseline care 0.69 vs. proposed models 0.73-0.76, p<0.05). However, there was little improvement in other test characteristics (baseline vs. best proposed model: sensitivity 21.7% [95% confidence interval 13.1-33.6] vs. 35.8%% [24.4-49.3], specificity 96.6% [93.4-98.3] vs. 94.7% [90.7-97.0], PPV 61.9% [40.9-79.3] vs. 63.3% [45.5-78.1], NPV 82.8% [77.9-86.8] vs. 85.2% [80.0-89.2], positive LR 6.3 [2.8-14.6] vs. 6.7 [3.4-3.3], negative LR 0.81 [0.71-0.93] vs. 0.68 [0.55-0.83]) and wide confidence intervals. Negative post-test probability remained high (16.7% vs. 14.0%). CONCLUSION: Antenatal placental assessment may improve identification of RFM pregnancies at highest risk of adverse pregnancy outcome but further work is required to understand and refine currently available outcome definitions and diagnostic techniques to improve clinical utility.


Assuntos
Movimento Fetal/fisiologia , Placenta/diagnóstico por imagem , Resultado da Gravidez , Adulto , Índice de Apgar , Estudos de Coortes , Cordocentese , Feminino , Humanos , Concentração de Íons de Hidrogênio , Recém-Nascido de Baixo Peso , Recém-Nascido , Terapia Intensiva Neonatal , Modelos Logísticos , Estudos Longitudinais , Modelos Biológicos , Morte Perinatal , Placenta/irrigação sanguínea , Valor Preditivo dos Testes , Gravidez , Estudos Prospectivos , Natimorto , Ultrassonografia Pré-Natal
3.
BMJ Open ; 7(8): e014813, 2017 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-28801392

RESUMO

BACKGROUND: In 2013, the stillbirth rate in the UK was 4.2 per 1000 live births, ranking 24th out of 49 high-income countries, with an annual rate of reduction of only 1.4% per year. The majority of stillbirths occur in normally formed infants, with (retrospective) evidence of placental insufficiency the most common clinical finding. Maternal perception of reduced fetal movements (RFM) is associated with placental insufficiency and increased risk of subsequent stillbirth.This study will test the hypothesis that the introduction of a package of care to increase women's awareness of the need for prompt reporting of RFM and standardised management to identify fetal compromise with timely delivery in confirmed cases, will reduce the rate of stillbirth. Following the introduction of a similar intervention in Norway the odds of stillbirth fell by 30%, but the efficacy of this intervention (and possible adverse effects and implications for service delivery) has not been tested in a randomised trial. METHODS: We describe a stepped-wedge cluster trial design, in which participating hospitals in the UK and Ireland will be randomised to the timing of introduction of the care package. Outcomes (including the primary outcome of stillbirth) will be derived from detailed routinely collected maternity data, allowing us to robustly test our hypothesis. The degree of implementation of the intervention will be assessed in each site. A nested qualitative study will examine the acceptability of the intervention to women and healthcare providers and identify process issues including barriers to implementation. ETHICS AND DISSEMINATION: Ethical approval was obtained from the Scotland A Research Ethics Committee (Ref 13/SS/0001) and from Research and Development offices in participating maternity units. The study started in February 2014 and delivery of the intervention completed in December 2016. Results of the study will be submitted for publication in peer-reviewed journals and disseminated to local investigating sites to inform education and care of women presenting with RFM. TRIAL REGISTRATION NUMBER: www.clinicaltrials.gov NCT01777022. VERSION: Protocol Version 4.2, 3 February 2017.


Assuntos
Sofrimento Fetal/diagnóstico , Monitorização Fetal/métodos , Movimento Fetal/fisiologia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Cooperação do Paciente/estatística & dados numéricos , Gestantes , Cuidado Pré-Natal/métodos , Conscientização , Medicina Baseada em Evidências , Feminino , Idade Gestacional , Promoção da Saúde , Humanos , Recém-Nascido , Irlanda , Masculino , Análise Multinível , Gravidez , Natimorto , Reino Unido
4.
Cochrane Database Syst Rev ; (10): CD004909, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26467769

RESUMO

BACKGROUND: Fetal movement counting is a method by which a woman quantifies the movements she feels to assess the condition of her baby. The purpose is to try to reduce perinatal mortality by alerting caregivers when the baby might be compromised. This method may be used routinely, or only in women who are considered at increased risk of complications affecting the baby. Fetal movement counting may allow the clinician to make appropriate interventions in good time to improve outcomes. On the other hand, fetal movement counting may cause unnecessary anxiety to pregnant women, or elicit unnecessary interventions. OBJECTIVES: To assess outcomes of pregnancy where fetal movement counting was done routinely, selectively or was not done at all; and to compare different methods of fetal movement counting. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 May 2015) and reference lists of retrieved studies. SELECTION CRITERIA: Randomised controlled trials (RCTs) and cluster-RCTs where fetal movement counting was assessed as a method of monitoring fetal wellbeing. DATA COLLECTION AND ANALYSIS: Two review authors assessed studies for eligibility, assessed the methodological quality of included studies and independently extracted data from studies. Where possible the effects of interventions were compared using risk ratios (RR), and presented with 95% confidence intervals (CI). For some outcomes, the quality of the evidence was assessed using the GRADE approach. MAIN RESULTS: Five studies (71,458 women) were included in this review; 68,654 in one cluster-RCT. None of these five trials were assessed as having low risk of bias on all seven risk of bias criteria. All included studies except for one (which included high-risk women as participants) included women with uncomplicated pregnancies.Two studies compared fetal movement counting with standard care, as defined by trial authors. Two included studies compared two types of fetal movement counting; once a day fetal movement counting (Cardiff count-to-10) with more than once a day fetal movement counting methods. One study compared fetal movement counting with hormone assessment.(1) Routine fetal movement counting versus mixed or undefined fetal movement countingNo study reported on the primary outcome 'perinatal death or severe morbidity'. In one large cluster-RCT, there was no difference in mean stillbirth rates per cluster (standard mean difference (SMD) 0.23, 95% CI -0.61 to 1.07; participants = 52 clusters; studies = one, low quality evidence). The other study reported no fetal deaths. There was no difference in caesarean section rate between groups (RR 0.93, 95% CI 0.60 to 1.44; participants = 1076; studies = one,low quality evidence). Maternal anxiety was significantly reduced with routine fetal movement counting (SMD -0.22, 95% CI -0.35 to -0.10; participants = 1013; studies = one, moderate quality evidence). Maternal-fetal attachment was not significantly different (SMD -0.02, 95% CI -0.15 to 0.11; participants = 951; studies = one, low quality evidence). In one study antenatal admission after reporting of decreased fetal movements was increased (RR 2.72, 95% CI 1.34 to 5.52; participants = 123; studies = one). In another there was a trend to more antenatal admissions per cluster in the counting group than in the control group (SMD 0.38, 95% CI -0.17 to 0.93; participants = 52 clusters; studies = one, low quality evidence). Birthweight less than 10th centile was not significantly different between groups (RR 0.98, 95% CI 0.66 to 1.44; participants = 1073; studies = one, low quality evidence). The evidence was of low quality due to imprecise results and because of concerns regarding unclear risk of bias. (2) Formal fetal movement counting (Modified Cardiff method) versus hormone analysisThere was no difference between the groups in the incidence of caesarean section (RR 1.18, 95% CI 0.83 to 1.69; participants = 1191; studies = one). Women in the formal fetal movement counting group had significantly fewer hospital visits than those randomised to hormone analysis (RR 0.26, 95% CI 0.20 to 0.35), whereas there were fewer Apgar scores less than seven at five minutes for women randomised to hormone analysis (RR 1.72, 95% CI 1.01 to 2.93). No other outcomes reported showed statistically significant differences. 'Perinatal death or severe morbidity' was not reported. (3) Formal fetal movement counting once a day (count-to-10) versus formal fetal movement counting method where counting was done more than once a day (after meals)The incidence of caesarean section did not differ between the groups under this comparison (RR 2.33, 95% CI 0.61 to 8.99; participants = 1400; studies = one). Perinatal death or severe morbidity was not reported. Women were more compliant in using the count-to-10 method than they were with other fetal movement counting methods, citing less interruption with daily activities as one of the reasons (non-compliance RR 0.25, 95% CI 0.19 to 0.32).Except for one cluster-RCT, included studies were small and used different comparisons, making it difficult to measure the outcomes using meta-analyses. The nature of the intervention measured also did not allow blinding of participants and clinicians.. AUTHORS' CONCLUSIONS: This review does not provide sufficient evidence to influence practice. In particular, no trials compared fetal movement counting with no fetal movement counting. Only two studies compared routine fetal movements with standard antenatal care, as defined by trial authors. Indirect evidence from a large cluster-RCT suggested that more babies at risk of death were identified in the routine fetal monitoring group, but this did not translate to reduced perinatal mortality. Robust research by means of studies comparing particularly routine fetal movement counting with selective fetal movement counting is needed urgently, as it is a common practice to introduce fetal movement counting only when there is already suspected fetal compromise.


Assuntos
Monitorização Fetal/métodos , Movimento Fetal/fisiologia , Feminino , Humanos , Gravidez , Resultado da Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo
5.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 59(5): 507-513, set.-out. 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-695291

RESUMO

Durante as últimas décadas, o desenvolvimento da ultrassonografia em tempo real tem possibilitado a visibilização direta do feto no útero, bem como a avaliação de sua atividade. Com o advento da ultrassonografia tridimensional (3D) no final dos anos 1980, iniciou-se uma nova era no diagnóstico por imagem em Obstetrícia, ampliando-se sobremaneira a possibilidade do estudo fetal. Recentemente, uma técnica que permitiu que a imagem 3D fosse transformada em um modo em tempo real foi introduzida e tem sido chamada de ultrassonografia em quarta dimensão (4D), a qual permite o monitoramento contínuo da face fetal e de outras áreas da superfície do feto, como, por exemplo, suas extremidades. Alguns estudos já se ocuparam em avaliar esta nova metodologia na observação do comportamento fetal durante diferentes estágios da gestação, na tentativa de melhor entender as relações entre a maturação do sistema nervoso central do feto e suas implicações em seu padrão de comportamento. No presente artigo, os autores realizam uma revisão sobre o uso atual da ultrassonografia 4D na avaliação do comportamento fetal, discorrendo sobre as perspectivas da técnica em espelhar, por meio da observação de padrões de movimentos e expressões faciais, o desenvolvimento neurológico do feto, destacando as potenciais aplicabilidades dessa tecnologia como nova área de pesquisa em medicina fetal.


In the last decades, the development of real-time ultrasonography has allowed the direct view of the fetus in the uterus, as well as assessing its activity. The advent of threedimensional ultrasonography (3D) at the end of the 80s initiated a new era in diagnostic imaging for Obstetrics, dramatically increasing the possibility of studying the fetus. Recently, a new technique allowing the 3D image to be transformed into real-time was introduced: the four-dimensional (4D) ultrasonography. It allows the continuous monitoring of fetal face and other surface areas, such as the extremities. Some studies have already assessed this new methodology for fetal behavior observation during different stages of pregnancy, trying to understand better the relationship between fetal central nervous system maturation and the implications for its behavior. In this article, the authors review the current use of 4D ultrasonography in the assessment of fetal behavior, and discuss the possibilities of the technique to show the neurological development of the fetus, by means of watching movement and facial expressions. They also highlight the potential applicability of this new method in this new research area of fetal medicine.


Assuntos
Feminino , Humanos , Gravidez , Movimento Fetal/fisiologia , Ultrassonografia Pré-Natal/métodos , Sistema Nervoso Central/embriologia , Expressão Facial
6.
Rev Assoc Med Bras (1992) ; 59(5): 507-13, 2013.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24007875

RESUMO

In the last decades, the development of real-time ultrasonography has allowed the direct view of the fetus in the uterus, as well as assessing its activity. The advent of three-dimensional ultrasonography (3D) at the end of the 80s initiated a new era in diagnostic imaging for Obstetrics, dramatically increasing the possibility of studying the fetus. Recently, a new technique allowing the 3D image to be transformed into real-time was introduced: the four-dimensional (4D) ultrasonography. It allows the continuous monitoring of fetal face and other surface areas, such as the extremities. Some studies have already assessed this new methodology for fetal behavior observation during different stages of pregnancy, trying to understand better the relationship between fetal central nervous system maturation and the implications for its behavior. In this article, the authors review the current use of 4D ultrasonography in the assessment of fetal behavior, and discuss the possibilities of the technique to show the neurological development of the fetus, by means of watching movement and facial expressions. They also highlight the potential applicability of this new method in this new research area of fetal medicine.


Assuntos
Movimento Fetal/fisiologia , Ultrassonografia Pré-Natal/métodos , Sistema Nervoso Central/embriologia , Expressão Facial , Feminino , Humanos , Gravidez
7.
Reprod Sci ; 20(4): 414-25, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23171680

RESUMO

We used real-time ultrasound to measure motility and abdominal diameter in fetal lambs at weekly intervals for 30 minutes from 55 days to term (n = 8). Fetal body movement counts/min were relatively constant between 55 and ~90 days and declined progressively thereafter, a relationship best described by piecewise linear regression with 2 elements. The break point in the regression curves averaged 91.9 ± 5.2 days. The relationship between gestational age and abdominal diameter was also best described by piecewise linear regression. The break point of 113.1 ± 3.9 days was significantly greater than the movement break point. There was a significant linear relationship between the movement and abdominal break points, with the latter occurring 21.6 ± 6.6 days later. These results suggest that both fetal motility and growth may decrease in order to lower fetal O2 demands to match the progressive decline in fetal O2 delivery with advancing gestation.


Assuntos
Abdome/diagnóstico por imagem , Movimento Fetal/fisiologia , Idade Gestacional , Mecânica Respiratória/fisiologia , Ultrassonografia Pré-Natal/tendências , Abdome/fisiologia , Animais , Sistemas Computacionais , Feminino , Feto/fisiologia , Gravidez , Respiração , Ovinos
8.
J Matern Fetal Neonatal Med ; 25(8): 1267-72, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22122157

RESUMO

OBJECTIVE: To assess differences in fetal behavior in both normal fetuses and fetuses with cerebral ventriculomegaly (VM). METHODS: In a period of eighteen months, in a longitudinal prospective cohort study, Kurjak Antenatal NeuorogicalTest (KANET) was applied to assess fetal behavior in both normal pregnancies and pregnancies with cerebral VM using four-dimensional ultrasound (4D US). According to the degree of enlargement of the ventricles, VM was divided into three groups: mild, moderate and severe. Moreover fetuses with isolated VM were separated from those with additional abnormalities. According to the KANET, fetuses with scores ≥ 14 were considered normal, those with scores 6-13 borderline and abnormal if the score was ≤ 5. Differences between two groups were examined by Fisher's exact test. Differences within the subgroups were examined by Kruskal-Wallis test and contingency table test. RESULTS: KANET scores in normal pregnancies and pregnancies with VM showed statistically significant differences. Most of the abnormal KANET scores as well as most of the borderline-scores were found among the fetuses with severe VM associated with additional abnormalities. There were no statistically significant differences between the control group and the groups with isolated and mild and /or moderate VM. CONCLUSION: Evaluation of the fetal behavior in fetuses with cerebral VM using KANET test has the potential to detect fetuses with abnormal behavior, and to add the dimension of CNS function to the morphological criteria of VM. Long-term postnatal neurodevelopmental follow-up should confirm the data from prenatal investigation of fetal behavior.


Assuntos
Encéfalo/fisiopatologia , Técnicas de Diagnóstico Neurológico , Feto/fisiopatologia , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Estudos de Casos e Controles , Estudos de Coortes , Ecoencefalografia/métodos , Feminino , Movimento Fetal/fisiologia , Humanos , Hidrocefalia/congênito , Estudos Longitudinais , Gravidez , Resultado da Gravidez , Projetos de Pesquisa
9.
Early Hum Dev ; 85(12): 785-90, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19944545

RESUMO

BACKGROUND: Fetal Akinesia Deformation Sequence (FADS) is a rare, in most cases autosomal recessive, disorder. Its heterogeneous origin results in variable onset and expression of motor and postural anomalies. DNA-diagnostic possibilities are limited, thus prenatal diagnosis is chiefly dependent on sonographic examinations. AIM: To explore postural and motor development from a systematic sonographic protocol for fetuses at high risk for FADS. Specific questions are: which motor (i.e., specific movement patterns, quality and quantity of general movements) and postural aspects are most informative about emerging FADS and is the gestational age of onset range of FADS more limited for siblings? METHODS: Ten families underwent 45, 15-minute sonographic assessments for motility and posture for ten index fetuses with FADS and nine subsequent pregnancies from five families. RESULTS: FADS was diagnosed between 18 and 33 weeks gestation in ten index pregnancies and between 11 and 18 weeks gestation in 4/9 subsequent pregnancies, 1-12 weeks earlier than their index pregnancies. From the four assessment aspects, posture and movement quality were always abnormal, movement quantity in 7/14 and differentiation into specific movement patterns were reduced in comparison with healthy siblings (p<0.01). Deterioration occurred in a 2 week period. CONCLUSIONS: Serial postural and qualitative assessments were most informative diagnosing FADS. Quantity and differentiation into specific movement patterns contributed substantially. Onset range of FADS within siblings was suggested to be more limited than between families.


Assuntos
Anormalidades Múltiplas/diagnóstico por imagem , Anormalidades Múltiplas/fisiopatologia , Movimento Fetal/fisiologia , Feto/fisiologia , Postura/fisiologia , Face/anormalidades , Face/diagnóstico por imagem , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Retardo do Crescimento Fetal/etiologia , Retardo do Crescimento Fetal/fisiopatologia , Monitorização Fetal/métodos , Idade Gestacional , Humanos , Artropatias/complicações , Artropatias/congênito , Artropatias/diagnóstico por imagem , Artropatias/fisiopatologia , Atividade Motora/fisiologia , Músculo Esquelético/embriologia , Músculo Esquelético/fisiologia , Poli-Hidrâmnios/diagnóstico por imagem , Poli-Hidrâmnios/fisiopatologia , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal/métodos
10.
J Matern Fetal Neonatal Med ; 22(2): 152-6, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19253163

RESUMO

OBJECTIVES: To observe a rate of fetal breathing and gross body movement appearance as physiologic reactions to the external vibroacoustic stimulation (VAS) and to establish a rapid and reliable antepartal method for accurate selecting of non-compromised fetuses in the low-risk population. METHODS: Actual condition of 742-term and near-term structurally normal and otherwise healthy singleton fetuses with favourable outcome was assessed by previously established combination of the modified fetal biophysical profile and VAS. Only inactive fetuses at the beginning of the testing were included in the study. The combined biophysical testing has been started by a transabdominal real-time ultrasound examination, followed by vibroacoustic stimulus applied over the fetal head for 5 s during fetal quiescence. Fetal breathing and gross body movements were observed with particular attention in each case at measured time intervals from the application of external VAS until the moment at which either the first 60-s episode of breathing movements or all three fetal gross body movements were detected. Obtained results have been presented numerically in 5-min periods and cumulative percentages. RESULTS: After the external VAS, 84.5% of studied fetuses successfully manifested their normal breathing or gross body movements in the first 5 min of the modified biophysical testing. Furthermore, approximately 96% of them were able to demonstrate at least one of these two biophysical activities after 6-7 min. DISCUSSION: Because of its simplicity, non-invasiveness, independence of precise gestational dating, reproducibility and immediate individual results, ultrasonographic observation of normal fetal breathing and/or gross body movements after the external VAS stands a real chance to become a nearly optimal antenatal test for accurate and rapid information of actual non-compromised fetal condition. Authors strongly believe that the described antenatal method should represent a rather efficient assessment procedure of fetal well-being in late pregnancy, performed during regular antenatal visits.


Assuntos
Estimulação Acústica , Movimento Fetal/fisiologia , Feto/fisiologia , Mecânica Respiratória/fisiologia , Ultrassonografia Pré-Natal , Vibração , Feminino , Humanos , Gravidez , Estudos Prospectivos , Medição de Risco
11.
Cochrane Database Syst Rev ; (1): CD004909, 2007 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-17253530

RESUMO

BACKGROUND: Fetal movement counting is a method by which a woman quantifies the movements she feels to assess the condition of the baby. The purpose is to try to reduce perinatal mortality by alerting caregivers when the baby might have become compromised. This method may be used routinely, or only in women who are considered at increased risk of complications in the baby. Some clinicians believe that fetal movement counting is a good method as it allows the clinician to make appropriate interventions in good time. On the other hand, fetal movement counting may cause anxiety to women. OBJECTIVES: To assess outcomes of pregnancy where fetal movement counting was done routinely, selectively or was not done at all; and to compare different methods of fetal movement counting. SEARCH STRATEGY: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 September 2006), the Cochrane Central Register of Controlled Trials (The Cochrane Library) and the reference lists of relevant papers. SELECTION CRITERIA: Randomised controlled trials. Trials were excluded where allocation concealment was inadequate and no measures were taken to prevent bias were excluded. The interventions included routine fetal movement counting, selective fetal movement counting, and studies comparing different fetal assessment methods. DATA COLLECTION AND ANALYSIS: We assessed the methodological quality of included studies and extracted data from studies. MAIN RESULTS: Four studies, involving 71,370 women, were included in this review; 68,654 in one cluster-randomised trial. All four trials compared formal fetal movement counting. Two trials compared different types of counting with each other; one with no formal instruction, and one with hormonal analysis. Women in the formal fetal movement counting group had significantly fewer visits to the hospital antenatally than those women randomised to hormone analysis (relative risk (RR) 0.26, 95% confidence interval (CI) 0.20 to 0.35), whereas there were fewer Apgar scores less than seven in five minutes for women randomised to hormone analysis (RR 1.72, 95% CI 1.01 to 2.93). There was a significantly higher compliance with the Cardiff 'count to ten' method than with the formal fetal movement counting method (RR 0.25, 95% CI 0.19 to 0.32).All other outcomes reported were non significant. AUTHORS' CONCLUSIONS: This review does not provide enough evidence to influence practice. In particular, no trials compared fetal movement counting with no fetal movement counting. Robust research is needed in this area.


Assuntos
Monitorização Fetal/métodos , Movimento Fetal/fisiologia , Feminino , Humanos , Gravidez , Resultado da Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
Ultrasound Obstet Gynecol ; 27(1): 41-47, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16323151

RESUMO

OBJECTIVE: Multi-vessel Doppler ultrasonography and biophysical profile scoring (BPS) are used in the surveillance of growth restricted fetuses (IUGR). The interpretation of both tests performed concurrently may be complex. This study examines the relationship between Doppler ultrasonography and biophysical test results in IUGR fetuses. METHODS: Three hundred and twenty-eight IUGR fetuses (abdominal circumference < 5th percentile, elevated umbilical artery (UA) pulsatility index (PI)) had concurrent surveillance with UA, middle cerebral artery (MCA) and ductus venosus (DV) Doppler ultrasonography and BPS (fetal tone, movement, breathing, maximal amniotic fluid pocket and fetal heart rate). Patients were stratified into three groups according to their Doppler examination: (1) abnormal UA alone; (2) brain sparing (MCA-PI > 2 SD below mean for gestational age); and (3) abnormal DV (PI > 2 SD above the mean for gestational age) and BPS groups: (1) normal (> 6/10); (2) equivocal (6/10); and (3) abnormal (< 6/10). Predictions of short-term perinatal outcomes by both modalities were compared for stratification. The distribution and concordance of Doppler and BPS test results were examined for the whole patient group and based on delivery prior to 32 weeks' gestation. RESULTS: Abnormal UA Doppler results alone were observed in 109 fetuses (33.2%), brain sparing in 87 (26.5%) and an abnormal DV in 132 (40.2%). The BPS was normal in 158 (48.2%), equivocal in 68 (20.7%) and abnormal in 102 (31.1%). Both testing modalities stratified patients into groups with comparable acid-base disturbance and perinatal outcome. Of the nine possible test combinations the largest subgroups were: abnormal UA alone/normal BPS (n = 69; 21%) and abnormal DV Doppler/abnormal BPS (n = 62; 18.9%). Assessment of compromise by both testing modalities was concordant in 146 (44.5%) cases. In 182 fetuses with discordant results the BPS grade was better in 115 (63.2%, P < 0.0001). Marked disagreement of test abnormality was present in 57 (17.4%) fetuses. Of these, abnormal venous Doppler in the presence of a normal BPS constituted the largest group (Chi-square P < 0.002). Stratification was not significantly different in patients delivered prior to 32 weeks' gestation. CONCLUSION: Doppler ultrasonography and BPS effectively stratify IUGR fetuses into risk categories, but Doppler and BPS results do not show a consistent relationship with each other. Since fetal deterioration appears to be independently reflected in these two testing modalities further research is warranted to investigate how they are best combined.


Assuntos
Biofísica/normas , Retardo do Crescimento Fetal/diagnóstico , Feto/embriologia , Ultrassonografia Doppler/normas , Ultrassonografia Pré-Natal/normas , Adolescente , Adulto , Líquido Amniótico , Feminino , Retardo do Crescimento Fetal/fisiopatologia , Movimento Fetal/fisiologia , Frequência Cardíaca Fetal/fisiologia , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Gravidez , Estudos Prospectivos , Fluxo Pulsátil , Respiração
13.
Ceylon Med J ; 50(4): 156-9, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16538910

RESUMO

RATIONALE: A healthy foetus, if exposed to external sound stimulation, often responds with vigorous movements which can be felt by the mother. A hypoxic foetus usually does not show this response. OBJECTIVES: To evaluate the fetal acoustic stimulation test (FAST) in antepartum fetal monitoring. DESIGN AND SETTING: Prospective interventional study carried out at the Teaching Hospital, Galle. METHOD: An initial non-stress test (NST) followed by a FAST using the Corometric model 146 was carried out in 423 high risk pregnant women. The response to FAST was assessed and compared with the NST. A repeat NST was recorded in women who had an initial non-reactive NST. The results of the NST and FAST were compared with the fetal outcome if the woman delivered within 24 hours. OUTCOME MEASURES: Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute Apgar scores if delivered within 24 hours of the FAST. RESULTS: Of the women, 349 (82.5%) noticed fetal movements after FAST. Of the 167 women who complained of absent or reduced fetal movements, 67% felt fetal movements after FAST. Ninety one had a nonreactive NST and 43 (47%) became reactive after FAST. Compared to the NST, the FAST had less sensitivity (93% vs 100%, p = 0.01), better specificity (79% vs 45%, p = 0.001), better positive predictive value (67% vs 50%, p = 0.02), similar negative predictive values (96% vs 100%, p > 0.05) and better accuracy (83% vs 69%, p = 0.03) in predicting neonatal asphyxia (5 minute Apgar score < 7) if the baby was delivered within 24 hours after the test. CONCLUSION: The FAST is a reliable, cost effective screening test for antepartum fetal monitoring. It significantly reduces the false positive (non-reactive) NST and has a good negative predictive value.


Assuntos
Estimulação Acústica , Monitorização Fetal/instrumentação , Movimento Fetal/fisiologia , Adulto , Cardiotocografia , Análise Custo-Benefício , Teste de Esforço , Feminino , Monitorização Fetal/economia , Hospitais de Ensino , Humanos , Valor Preditivo dos Testes , Gravidez , Estudos Prospectivos , Sri Lanka
14.
Exp Neurol ; 190 Suppl 1: S65-71, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15498544

RESUMO

Fetal magnetocardiography (fMCG) offers unique capabilities for assessment of fetal heart rate (FHR) and fetal behavior, which are fundamental aspects of neurodevelopment. The most important attribute of fMCG for FHR monitoring is its high precision, which allows accurate assessment of beat-to-beat fetal heart rate variability (FHRV), including respiratory sinus arrhythmia. Using mathematical indices to assess FHRV, we find that short- and long-term FHRV both increase during gestation but not in the same manner. The largest increases in short-term FHRV occur during the last trimester, while the largest increases in long-term FHRV occur early on, with smaller changes occurring during the last trimester. The fMCG also allows assessment of fetal activity. This results from the high sensitivity of the signal to the position and orientation of the fetal heart. FMCG actograms are therefore specific for fetal trunk movement, which are thought to be more important than isolated extremity movements and other small fetal movements. The ability to assess FHR, FHRV, and fetal trunk movement simultaneously makes fMCG a valuable tool for neurodevelopment research.


Assuntos
Eletrocardiografia/métodos , Desenvolvimento Fetal/fisiologia , Feto/fisiologia , Magnetismo , Fenômenos Fisiológicos do Sistema Nervoso , Eletrocardiografia/instrumentação , Feminino , Movimento Fetal/fisiologia , Idade Gestacional , Frequência Cardíaca Fetal/fisiologia , Humanos , Sistema Nervoso/embriologia , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Sensibilidade e Especificidade
15.
Acta Obstet Gynecol Scand ; 83(9): 818-26, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15315592

RESUMO

A reduction or cessation of fetal movements (FMs) is frequently reported by pregnant women and causes concern and anxiety. However, the clinical significance of a history of reduced FMs remains unclear, and the assessment and management of these pregnancies is controversial. This article is a review of the literature on decreased FMs found in medline and the cochrane library using the search phrases: decreased FMs, perinatal outcome, FM monitoring, and fetal assessment. Formal counting of FMs by the pregnant woman could possibly identify the fetuses, which are at risk of compromise, thus allowing for appropriate action. However, the benefit of this intervention has not been definitely proven. Cardiotocography, umbilical/uterine artery Doppler velocimetry, and ultrasonography have been used for antepartum fetal assessment in pregnancies with decreased FMs, but the evidence of a clinical benefit is limited. The effects of fetal assessment with vibroacoustic stimulation and biophysical profile are unknown and should be further evaluated. Present recommendations on the management of pregnancies with decreased FMs are based on limited and inconsistent scientific evidence. There is a need for further well-designed studies in order to provide evidence-based guidelines in the future.


Assuntos
Doenças Fetais/diagnóstico por imagem , Doenças Fetais/terapia , Movimento Fetal/fisiologia , Frequência Cardíaca Fetal/fisiologia , Resultado da Gravidez , Ultrassonografia Pré-Natal/métodos , Adulto , Cardiotocografia/métodos , Estudos de Casos e Controles , Feminino , Morte Fetal/prevenção & controle , Doenças Fetais/diagnóstico , Monitorização Fetal , Seguimentos , Idade Gestacional , Humanos , Gravidez , Cuidado Pré-Natal/métodos , Medição de Risco
16.
Early Hum Dev ; 50(1): 1-11, 1997 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-9467689

RESUMO

The paper provides a survey of the state of the art of a new neurological diagnostic procedure in fetuses, preterm and term infant as well as in young infants. This method consists of a judgement of the movement quality of a particular type of spontaneous movements, the so-called general movements. At a very early age normal and abnormal general movement quality predicts the neurological outcome over 2 years, in particular cerebral palsy. The reliability of this method turned out to be very robust. Recent animal experiments on isolated parts of the central nervous system provide convincing evidence of endogenously generated neural activity. Similar neural mechanisms must provide the basis for spontaneous movements seen in the human at early ages. Those neural defects leading to qualitative changes of general movements are described in detail.


Assuntos
Encéfalo/patologia , Paralisia Cerebral/diagnóstico , Doenças Fetais/diagnóstico , Feto/fisiologia , Exame Neurológico/métodos , Animais , Encéfalo/embriologia , Paralisia Cerebral/fisiopatologia , Feminino , Doenças Fetais/embriologia , Movimento Fetal/fisiologia , Feto/embriologia , Humanos , Lactente , Recém-Nascido , Estudos Longitudinais , Movimento/fisiologia , Gravidez
17.
Early Hum Dev ; 50(1): 13-25, 1997 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-9467690

RESUMO

The effect of type-I diabetes on the quality of general movements (GMs) was studied longitudinally in 12 human fetuses. GMs were analysed at two-weekly intervals from 16 weeks until delivery. A pregnancy optimality-score and a diabetes optimality-score were used to cover the course of the pregnancy and delivery and the severity of diabetes. GMs of infants were analysed 1, 4-6, and 12-18 weeks after birth and the Bayley developmental test was performed at 10 months. All fetuses showed normal GMs at 16 weeks. From 20 weeks onwards until delivery five fetuses developed abnormal GMs. The diabetes optimality-score was significantly lower in the group with abnormal GMs (P = 0.018) whereas the pregnancy optimality-score did not differ between fetuses with normal and abnormal GMs. Our results indicate that type-I diabetes can have a negative impact on prenatally observed GMs. Consistently normal GMs indicate normal neurodevelopmental outcome at 10 months whereas in the group with abnormal GMs reduced Bayley-scores may occur.


Assuntos
Diabetes Mellitus Tipo 1/fisiopatologia , Movimento Fetal/fisiologia , Feto/fisiologia , Gravidez em Diabéticas/fisiopatologia , Adulto , Glicemia , Sistema Nervoso Central/embriologia , Sistema Nervoso Central/fisiopatologia , Feminino , Humanos , Lactente , Recém-Nascido , Estudos Longitudinais , Movimento/fisiologia , Exame Neurológico , Gravidez , Complicações na Gravidez , Ultrassonografia Pré-Natal , Gravação de Videoteipe
18.
Early Hum Dev ; 50(1): 47-60, 1997 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-9467693

RESUMO

We describe the state of the art of Prechtl's method for the qualitative assessment of general movements as a diagnostic tool for early detection of brain dysfunction. After discussing the optimal technique for video recording general movements in preterm, term and young infants, attention is focused on the proper analysis of this spontaneous motor pattern. Recently, a group of active researchers in the field reached consensus on the various qualities of normal and abnormal general movements. These definitions are reported here in full. Since it is a newly introduced method careful investigation into its reliability is required. Various groups of investigators have obtained data which demonstrate the robust character of the method (interscorer agreement: 78-98%). Finally, we discuss the validity of this early assessment method on the basis of the reports published so far. While the method's sensitivity is similar in all age groups studied (preterm, term, first month, second month, and third month age epochs), and averages 94.5%, the specificity of the method is age-dependent. It is low during the early ages, increases gradually and reaches 82 to 100% at 3 months post-term. This phenomenon is explained by spontaneous recovery of early dysfunction. In contrast, consistent abnormalities of general movements are linked to neurological deficits found at the 2 year follow-up.


Assuntos
Encefalopatias/diagnóstico , Movimento Fetal/fisiologia , Feto/fisiologia , Comportamento do Lactente/fisiologia , Exame Neurológico/métodos , Encefalopatias/fisiopatologia , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal , Gravação em Vídeo/métodos
19.
J Obstet Gynaecol Res ; 23(6): 537-41, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9433045

RESUMO

OBJECTIVE: To assess the reliability and application of maternal perception of sound provoked fetal movement for antepartum assessment of fetal well-being. METHODS: Six hundred singleton high risk pregnant women of at least 32 weeks gestation were studied on 684 occasions. The response was compared with a nonstress test (NST) performed before a 3 second vibroacoustic stimulation with an electronic artificial larynx. The result of maternal perception of sound provoked fetal movement was compared to the NST and the perinatal outcome using sensitivity, specificity, negative predictive value, positive predictive value, and accuracy. RESULTS: On 684 occasions, a positive response to sound stimulation, recorded as a fetal movement by the mother, occurred on 642 occasions (93.9%) and was accompanied by a reactive NST on 630 occasions; giving a specificity of 97.1% and a negative predictive value of 98.1%. Results of maternal perception of sound provoked fetal movement and NST, performed within a week of delivery, in 560 women were compared with perinatal outcome. The maternal perception of sound provoked fetal movement test had better sensitivity (64.7%) for poor perinatal outcome than the NST (58.8%). Both tests were not different in specificity (96.3% vs 96.5%), positive predictive value (35.5% vs 34.5%), negative predictive value (98.9% vs 98.7%), and accuracy (95.4% vs 95.4%). CONCLUSION: The findings suggested that maternal perception of sound provoked fetal movement may be an effective screening test to identify fetal compromise in antepartum period. This test is a simple and inexpensive test for evaluating fetal well-being in primary health care setting.


Assuntos
Estimulação Acústica , Doenças Fetais/diagnóstico , Movimento Fetal/fisiologia , Mães , Percepção , Adulto , Feminino , Sofrimento Fetal/diagnóstico , Idade Gestacional , Humanos , Gravidez , Resultado da Gravidez , Fatores de Risco , Sensibilidade e Especificidade , Vibração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA