Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 533
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Oral Rehabil ; 51(9): 1848-1861, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38767032

RESUMO

BACKGROUND: The temporal tendon is a structure often compromised in patients suffering from temporomandibular disorders (TMD), yet its intraoral location makes a standardised assessment difficult. OBJECTIVES: To evaluate the variability and accuracy to target force of a newly designed intraoral extension for a palpometer device (Palpeter, Sunstar Suisse) when compared to manual palpation, in addition to clinically assessing the mechanical sensitivity and referred sensations of the temporal tendon in healthy individuals. METHODS: Experiment 1: 12 individuals were asked to target on a scale 0.5, 1 and 2 kg, for 2 and 5 s by using five different methods (Palpeter, Palpeter with three different extension shapes and manual palpation). Experiment 2: 10 healthy participants were recruited for a randomised double-blinded assessment by applying pressure of 0.5, 1 and 2 kg to the right temporal tendon with the three extensions and manual palpation. Participants rated the intensity of their sensation/pain on a 0-50-100 numeric rating scale (NRS), unpleasantness on a 0-100 NRS, and if present, they rated and drew the location of referred sensations. Repeated measures analysis of variance (ANOVA) was used in both experiments to compare differences between palpation methods. Tukey's HSD tests were used for the post hoc comparisons, and p values below .05 were considered significant. RESULTS: Experiment 1: The extensions showed no significant differences between them regarding reliability and accuracy for all forces and durations (p > .05). The manual method was significantly less reliable and accurate when compared to the other methods (p < .05). Experiment 2: There were no significant differences between the Palpeter extensions regarding pain intensity or unpleasantness NRS scores (p > .05), but all the extensions had significantly increased pain intensity and unpleasantness when compared to manual palpation (p < .05). Similarly, the frequency of referred sensations was similar between extensions but increased when compared to manual palpation. CONCLUSIONS: The new Palpeter extensions proved to be significantly more accurate and have lower test-retest variability than the manual method in a non-clinical setting. Clinically, they showed no significant differences in NRS scores for pain intensity nor unpleasantness, with no major differences in referred sensations, making any of the extensions suitable for clinical testing of the temporal tendon in future studies.


Assuntos
Palpação , Tendões , Humanos , Palpação/métodos , Feminino , Reprodutibilidade dos Testes , Masculino , Adulto , Tendões/fisiologia , Tendões/fisiopatologia , Método Duplo-Cego , Medição da Dor , Voluntários Saudáveis , Adulto Jovem , Músculo Temporal/fisiologia , Músculo Temporal/fisiopatologia , Transtornos da Articulação Temporomandibular/fisiopatologia , Transtornos da Articulação Temporomandibular/diagnóstico , Dor Facial/fisiopatologia , Dor Facial/diagnóstico , Pressão
2.
Urol Oncol ; 42(6): 176.e1-176.e7, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38508941

RESUMO

PURPOSE: To evaluate the value of examination under anesthesia (EUA) in the assessment of bladder resectability during cystectomy. MATERIALS AND METHODS: This prospective study included consecutive patients undergoing cystectomy for bladder cancer at a single center between June 2017 and October 2020. EUA was conducted before cystectomy by two urologists who assessed the bladder for limited mobility. One examiner was blinded to the imaging results. Soft tissue surgical margin status in the pathological evaluation of a cystectomy specimen served as a measure of resectability. We used multivariable logistic regression models to assess whether EUA performed by blinded or non-blinded examiners is associated with soft tissue positive surgical margins (PSMs) and to calculate the fraction of new information added by such an examination in addition to selected clinical variables. RESULTS: Among the 134 patients analyzed, limited bladder mobility was indicated by the blinded and non-blinded examiners in 23 (17.2%) and 21 (15.7%) cases, respectively. PSMs were identified in 22 (16.4%) patients, more often in patients with limited bladder mobility as assessed by the blinded (odds ratio [OR] 6.7; 95% confidence interval [CI], 1.9-24.2) and non-blinded examiners (OR 12.9; 95% CI, 2.9-57.5). The fraction of new information added by the blinded and non-blinded examiners was 48.6% and 57.7%, respectively. The enrichment of patients who underwent pure laparoscopic cystectomy (n = 102; 76%) and the inclusion of patients for emergent surgery may limit the generalizability of our findings. CONCLUSIONS: The identification of limited bladder mobility during preoperative EUA yielded prognostic information on surgical margin status. Our findings suggest that EUA has the potential to provide valuable insights in the assessment of bladder resectability. However, further research in a larger cohort of patients is warranted to validate and expand on these findings.


Assuntos
Cistectomia , Laparoscopia , Palpação , Neoplasias da Bexiga Urinária , Humanos , Cistectomia/métodos , Neoplasias da Bexiga Urinária/cirurgia , Neoplasias da Bexiga Urinária/patologia , Estudos Prospectivos , Feminino , Masculino , Idoso , Laparoscopia/métodos , Pessoa de Meia-Idade
3.
J ISAKOS ; 9(3): 348-352, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38492848

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the validity and reliability of two techniques, palpation and fluoroscopy, for assessing medial patellofemoral ligament (MPFL) reconstruction femoral tunnel position accuracy. METHODS: Twenty-one fresh frozen cadaveric knees had an MPFL femoral tunnel drilled and filled with a metal screw. Tunnels were created in a nonstandard fashion to ensure the sample included a range of tunnel positions from poor to ideal. Six experienced sport medicine and arthroscopy surgeons evaluated the placement of the femoral tunnel by palpating the screw in relation to anatomic landmarks and by fluoroscopy related to Schöttle's Point. They evaluated 1) the accuracy of femoral tunnel placement, 2) the direction of tunnel error, and 3) the clinical acceptability of the tunnel position. Validity measures included sensitivity, specificity, and correlation to clinical acceptability, which were calculated for the palpation and fluoroscopic assessments. Reliability measures included interrater reliability (ICC 2,k) for femoral tunnel accuracy and percent agreement of the raters' tunnel direction assessment. RESULTS: The palpation method demonstrated a sensitivity of 0.79 and specificity of 0.84 for assessing the accuracy of femoral tunnel placement, while the fluoroscopic method showed a sensitivity of 0.83 and specificity of 0.92. Pearson correlation coefficients for clinical acceptability of tunnel position were high, with both techniques ranging from .589 to .854. Interrater reliability for the palpation and fluoroscopic techniques for assessment of tunnel accuracy were 0.31 and 0.55 (ICC 2,k), respectively. Assessment of the direction of tunnel error was good with the fluoroscopic technique slightly more accurate than palpation. CONCLUSION: This study demonstrated that both palpation and fluoroscopy are valid techniques for assessing femoral tunnel position after MPFL reconstruction. Despite demonstrating good validity, the accuracy of assessing tunnel position was unreliable in a group of six experienced knee surgeons. Further research into MPFL reconstruction femoral tunnel assessment techniques, including patient-specific reference standards, is warranted. LEVEL OF EVIDENCE: Level 2.


Assuntos
Cadáver , Fêmur , Palpação , Articulação Patelofemoral , Humanos , Fluoroscopia/métodos , Palpação/métodos , Reprodutibilidade dos Testes , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Articulação Patelofemoral/cirurgia , Articulação Patelofemoral/diagnóstico por imagem , Masculino , Feminino , Procedimentos de Cirurgia Plástica/métodos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Idoso , Parafusos Ósseos
4.
Int Urogynecol J ; 35(4): 823-830, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329494

RESUMO

INTRODUCTION AND HYPOTHESIS: Involuntary pelvic floor muscle (PFM) contractions are thought to occur during an increase in intra-abdominal pressure (IAP). Although no studies have assessed their presence in women with normal pelvic floor (PF) function, existing literature links the absence of involuntary PFM contractions to various PF dysfunctions. This study rectifies this lacuna by evaluating involuntary PFM contractions during IAP in healthy nulliparous women with no PF dysfunction, using visual observation and vaginal palpation. Results were compared with the literature and the IUGA/ICS Terminology Reports. METHODS: Nulliparous (n=149) women performed three sets of three maximal coughs. Visual observation and vaginal palpation were conducted in the standing and supine positions. The women were not instructed to contract their PFMs. Occurrence rates were calculated for each assessment method and position; differences between positions were analyzed using the Chi-squared test. RESULTS: Rates of occurrence of involuntary PFM contraction were low across both assessments and positions (5-17%). Significant differences were found between standing (5%) and supine (15%) positions for visual observation, but not vaginal palpation (15%, 17% respectively). Occurrence rates also differed compared with the literature and terminology reports. CONCLUSIONS: Contrary to clinical expectations, rates of occurrence of involuntary PFM contraction among our cohort of nulliparous women were extremely low. Digital palpation results showed high agreement with the terminology reports, but only partial agreement was observed for the visual observation results. Our study underscores the need for more research aimed at defining normal involuntary PF functions, a review of our understanding of involuntary PFM contractions, and better standardized guidelines for involuntary PFM assessment methods.


Assuntos
Contração Muscular , Diafragma da Pelve , Humanos , Feminino , Adulto , Diafragma da Pelve/fisiopatologia , Contração Muscular/fisiologia , Adulto Jovem , Terminologia como Assunto , Palpação
5.
BJOG ; 131(6): 843-847, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37846213

RESUMO

OBJECTIVE: To examine the concurrent validity and inter-rater reliability of vaginal palpation as a measure of the quality of the bearing-down manoeuvre (BDM) and the detection of a paradoxical levator ani muscle contraction (LAM) in pregnant women, compared with 2D transperineal ultrasound (TPUS). DESIGN: Concurrent validity and inter-rater reliability study. SETTING: Physiotherapy clinic. POPULATION: Twenty pregnant women in their third trimester. METHODS: The anterior posterior diameter (APD) was measured during the BDM using TPUS by one experienced physiotherapist. An APD that shortened by >2 mm from rest was described as LAM shortening, an APD that moved by 0-2 mm was described as no change and an APD that lengthened by >2 mm was described as LAM lengthening. Vaginal palpation described the LAM during the BDM as no movement, shortening or lengthening. Participants were allowed two attempts and the best attempt was measured. MAIN OUTCOME MEASURES: APD using TPUS and the assessor's subjective description of LAM during the BDM using vaginal palpation. RESULTS: TPUS detected more paradoxical LAM contractions during the BDM than palpation. Agreement between vaginal palpation and TPUS assessment for BDM was poor. The Fleiss kappa coefficients were 0.457 (90% CI 0.16-0.71) between TPUS and one assessor and 0.326 (90% CI 0.01-0.6) between TPUS and the other assessor. In addition, inter-rater reliability was poor between observers palpating the BDM, with a Fleiss kappa coefficient of 0.375 (90% CI 0.13-0.64). CONCLUSIONS: This study did not find vaginal palpation of the BDM in pregnant women to have concurrent validity or inter-rater reliability. Clinicians should be aware of potential inaccuracies when palpating the BDM, and, where possible, seek an assessment via TPUS.


Assuntos
Contração Muscular , Palpação , Gravidez , Feminino , Humanos , Reprodutibilidade dos Testes , Contração Muscular/fisiologia , Ultrassonografia , Terceiro Trimestre da Gravidez
6.
J Oral Rehabil ; 51(3): 601-610, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37994202

RESUMO

BACKGROUND: The evaluation of muscle pain and sensitivity by manual palpation is an important part of the clinical examination in patients with myalgia. However, the effects of clinical experience and visual feedback on palpation of the masticatory muscles with or without a palpometer are not known. OBJECTIVE: To estimate the effects of clinical experience and visual feedback on the accuracy of palpation in standardized settings. METHODS: Thirty-two dentists (age 35 ± 11 years) classified as either specialists (n = 16) or generalists (n = 16) participated in this experiment. All dentists were instructed to target force levels of 500- or 1000-gf, as determined on an electronic scale using either standardized palpometers or manual palpation (MP). All dentists participated in four different tests: MP, MP with visual feedback (MPVF), palpometer (PAL) and PAL with visual feedback (PALVF). Actual force values for each type of palpation from 0 to 2, 2 to 5 and 0 to 5 s were analysed by calculating target force level. RESULTS: The relative differences during 2-5 and 0-5 s with 1000 gf were significantly lower for generalists than for specialists (p < .05). In generalists and specialists, the coefficients of variation and the relative differences during 2-5 s were significantly lower for PAL and PALVF than for MP (p < .05). CONCLUSIONS: These findings suggest that the use of a palpometer, but not clinical experience with palpation of masticatory muscles, increases the accuracy of palpation, and ≥2 s of palpation with a palpometer is optimal for masticatory muscles.


Assuntos
Retroalimentação Sensorial , Palpação , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Exame Físico , Músculos da Mastigação , Mialgia
7.
Home Healthc Now ; 41(4): 182-189, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37417569

RESUMO

Respiratory illnesses often require acute care admissions and are a leading cause of death globally, thus creating a financial burden for healthcare systems. Home healthcare clinicians can significantly reduce morbidity and hospital readmissions by becoming proficient at respiratory assessment. This article aims to assist homecare clinicians in performing a respiratory assessment in a logical and structured approach, including inspection, palpation, percussion, and auscultation. This article reviews the anatomy and physiology of the respiratory system and describes subjective and objective respiratory assessment. It is anticipated that becoming adept at these skills will enable home healthcare clinician to assess and identify those patients at risk for deterioration and readmission.


Assuntos
Auscultação , Exame Físico , Humanos , Percussão , Palpação , Hospitalização , Readmissão do Paciente
8.
Proc Inst Mech Eng H ; 237(5): 571-584, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37062899

RESUMO

A calibrated palpation sensor has been developed for making instrumented Digital Rectal Examinations (iDREs) with a view to assessing patients for prostate cancer. The instrument measures the dynamic stiffness of the palpable surface of the prostate, and has been trialled on 12 patients in vivo. The patients had been diagnosed with prostate cancer and were scheduled for radical prostatectomy. As far as possible, patients with asymmetric disease were chosen so as to give a variation in gland condition over the palpable surface. The device works by applying an oscillating pressure (force) to a flexible probe whose displacement into the tissue is also measured in order to yield a dynamic stiffness, the static stiffness being incidentally measured at the mean oscillatory force. The device was deployed mounted on the index finger of a urologist and measurements taken at 12-16 positions on each patient using light and firm pressure and palpation frequencies of 1 or 5 Hz. In parallel, conventional DRE assessments were made by a consultant urologist for cancer. After in vivo measurement, the glands were removed and examined histologically with each palpation point being classified as cancerous (C) or not (NC). The work has established the first measurements of static modulus of living prostate tissue to be: 26.8 (13.3) kPa for tissue affected by prostate cancer (C classification), and 24.8 kPa (11.9) for tissue unaffected by cancer (NC classification), values quoted as median (interquartile range). The dynamic properties were characterised by: dynamic modulus, 5.15 kPa (4.86) for the C classification and 4.61 kPa (3.08) for the NC classification and the time lag between force and displacement at 5 Hz palpation frequency, 0.0175 s (0.0078) for the C classification and 0.0186 s (0.0397) for the NC classification, values again quoted as median (interquartile range). With the limited set of features that could be generated, an Artificial Neural Network (ANN) classification yielded a sensitivity of 97%, negative predictive value of 86%, positive predictive value of 67% and accuracy of 70% but with relatively poor specificity (30%). Besides extending the feature set, there are a number of changes in probe design, probing strategy and in mechanics analysis, which are expected to improve the diagnostic capabilities of the method.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Palpação , Fenômenos Mecânicos
9.
Sci Rep ; 13(1): 5580, 2023 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-37020098

RESUMO

Pilot balloon palpation is still a commonly used method to evaluate cuff pressure of the endotracheal tube after intubation. This study determined whether the size of the tracheal tube influenced the accuracy of pilot balloon palpation. A prospective observational analysis of 208 patients intubated with an endotracheal tube of internal diameter (ID) 6.0 or 8.0 was conducted. An anesthesiologist judged the cuff pressure by manual pilot balloon palpation, and then measured the cuff pressure with a pressure gauge. Cuff pressure exceeding 20-30 cmH2O was defined as false recognition. The intracuff pressure was significantly higher in ID 6.0 tube than in the ID 8.0 tube (41.9 ± 18.8 cmH2O vs. 30.3 ± 11.9 cmH2O, p < 0.001). The number of patients that were mistakenly perceived to have appropriate cuff pressure by pilot balloon palpation was significantly higher in the ID 6.0 group compared to the ID 8.0 group (85 (81.7%) vs. 64 (61.5%), p = 0.001). Therefore, a smaller tube size may further increase risk of inaccurate measurement by pilot balloon palpation and although pressure gauge is recommended for all sizes to maximize accuracy, groups with increased risk factors should be targeted for standardized use of the pressure gauge.


Assuntos
Anestesiologistas , Intubação Intratraqueal , Humanos , Pressão , Estudos Prospectivos , Intubação Intratraqueal/métodos , Palpação
10.
J Endod ; 49(2): 129-136, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36455705

RESUMO

INTRODUCTION: Masticatory myofascial pain is a musculoligamentous syndrome that can mimic odontogenic pain. Pain referral to odontogenic structures can be traced to hyperirritated myofascial trigger points (MTrPs). This pragmatic study evaluated the concordance between ultrasonography and palpation in detecting MTrPs in the masseter and temporalis muscles. METHODS: Fifty-seven patients suspected to have temporomandibular disorder were included. MTrPs were palpated manually by expert clinicians. Ultrasonography was then performed by a blind sonographer. The quantity of MTrPs and the involved muscle sections, the pain occurrence, and the location of the MTrPs within the muscle sections were compared using the mean difference (MD) and concordance statistics (Cohen κ and the interclass correlation coefficient [ICC]) as applicable. RESULTS: Ultrasonography located MTrPs as 2.1 ± 1.3 mm2 hypoechoic nodules at a depth of 7 ± 3.3 mm. Ultrasonography moderately agreed with palpation on the quantity of MTrPs per patient (MD = 1; 95% confidence interval [CI], 0.06-1.9; ICC = 0.56; 95% CI, 0.32-0.72). Palpation detected marginally more involved muscle sections per patient (MD = 0.7; 95% CI, 0.06-1.34.05; ICC = 0.64; 95% CI, 0.44-0.77) with more pain occurrence per patient (MD = 1.4; 95% CI, 0.56-2.28; ICC = 0.13; 95% CI, -0.26 to 0.41). There was a discordance in the location of the MTrPs within the muscle sections per patient (κ = -0.46; 95% CI, -0.77 to -0.14). CONCLUSIONS: Ultrasonography and palpation concurred moderately to substantially on the quantity of MTrPs and the involved muscle sections but disagreed on the location of the MTrPs within the muscle sections. Ultrasonography has the potential as a chairside diagnostic aid to help clinicians determine an accurate diagnosis, enhance patient experience during examination, and avoid unnecessary treatments that can mitigate the risk of iatrogenic damage.


Assuntos
Síndromes da Dor Miofascial , Pontos-Gatilho , Humanos , Pontos-Gatilho/diagnóstico por imagem , Síndromes da Dor Miofascial/diagnóstico por imagem , Ultrassonografia , Palpação , Dor
11.
Sci Rep ; 12(1): 18716, 2022 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-36333449

RESUMO

The ensuing pilot investigation sheds new light on characterizing tumoral and non-tumoral human skin mechanical properties that will not only assist the dermatologist's diagnosis but also could constitute the creation of an Artificial Intelligence database for upcoming research. A modern, non-invasive, and contact-free methodology-UNDERSKIN-was developed, and hinges upon Fourier transform computations that permit the analysis of surface wave dispersion with a specific skin inversion model and viscoelastic model. It yields a detailed look at how particle movements of the medium propagate throughout its near sub-surface, hence a novel knowledge of the mechanical responses of skin tumors. The research results display the tumors' viscoelastic responses alongside their respective healthy skin outcomes for each skin layer as well as the dermatologist's touch analysis. Although dermatologists are capable of sensing and having a fair overall assessment of what they are palpating, they are unable heretofore to quantify it and inform where the firmness or softness derives from, which it is necessary to be acquainted with so as to perform an accurate diagnosis, prognosis, treatment, future surgery, and teledermatology.


Assuntos
Inteligência Artificial , Neoplasias Cutâneas , Humanos , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/patologia , Viscosidade , Pele/patologia , Palpação
12.
Nurs Stand ; 37(3): 75-82, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34931506

RESUMO

Nurses frequently encounter patients in respiratory distress or with respiratory complications, whether from acute disease or a long-term condition. A physical examination of the chest should be conducted as part of a comprehensive respiratory assessment of the patient, and should follow a systematic approach that includes inspection, palpation, percussion and auscultation. Nurses undertaking these hands-on components of respiratory assessments need to have adequate knowledge of the procedures involved, as well as practical skills that need to be practised under supervision. This article outlines how to undertake a physical examination of the chest in adults.


Assuntos
Auscultação , Exame Físico , Adulto , Humanos , Palpação/métodos , Percussão , Exame Físico/métodos , Tórax
13.
Chiropr Man Therap ; 29(1): 33, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-34446040

RESUMO

BACKGROUND: Static or motion manual palpation of the low back is commonly used to assess pain location and reproduction in low back pain (LBP) patients. The purpose of this study is to review the reliability and validity of manual palpation used for the assessment of LBP in adults. METHOD: We systematically searched five databases from 2000 to 2019. We critically appraised internal validity of studies using QAREL and QUADAS-2 instruments. We stratified results using best-evidence synthesis. Validity studies were classified according to Sackett and Haynes. RESULTS: We identified 2023 eligible articles, of which 14 were low risk of bias. Evidence suggests that reliability of soft tissue structures palpation is inconsistent, and reliability of bony structures and joint mobility palpation is poor. We found preliminary evidence that gluteal muscle palpation for tenderness may be valid in differentiating LBP patients with and without radiculopathy. CONCLUSION: Reliability of manual palpation tests in the assessment of LBP patients varies greatly. This is problematic because these tests are commonly used by manual therapists and clinicians. Little is known about the validity of these tests; therefore, their clinical utility is uncertain. High quality validity studies are needed to inform the clinical use of manual palpation tests.


Assuntos
Dor Lombar , Radiculopatia , Adulto , Humanos , Dor Lombar/diagnóstico , Palpação , Amplitude de Movimento Articular , Reprodutibilidade dos Testes
14.
Br J Surg ; 108(7): 843-850, 2021 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-33638646

RESUMO

BACKGROUND: The aim was to determine the cost-effectiveness of radioguided occult lesion localization using 125I-labelled seeds (125I seeds) versus hookwire localization in terms of incremental cost per reoperation avoided for women with non-palpable breast cancer undergoing breast-conserving surgery. METHODS: This study was based on a multicentre RCT with eight study sites comprising seven public hospitals and one private hospital. An Australian public health system perspective was taken. The primary effectiveness outcome for this study was reoperations avoided. Cost-effectiveness was expressed as an incremental cost-effectiveness ratio (ICER). One-way and probabilistic sensitivity analyses were used to explore uncertainty. The willingness to pay (additional cost of localization using 125I seeds justified by reoperation cost avoided) was set at the weighted, top-down cost of reoperation. Costs were in 2019 Australian dollars ($1 was equivalent to €0.62). RESULTS: The reoperation rate was 13.9 (95 per cent confidence interval 10.7 to 18.0) per cent for the 125I seed group and 18.9 (14.8 to 23.8) per cent for the hookwire localization group. The ICER for 125I seed versus hookwire localization was $4474 per reoperation averted. The results were most sensitive to uncertainty around the probability of reoperation. Accounting for transition probability and cost uncertainty for 125I seed localization, there was a 77 per cent probability that using 125I seeds would be cost-effective, with a willingness to pay of $7693 per reoperation averted. CONCLUSION: Radioguided occult lesion localization using 125I seeds is likely to be cost-effective, because the marginal (additional) cost compared with hookwire localization is less than the cost of reoperations avoided.


Assuntos
Neoplasias da Mama/economia , Radioisótopos do Iodo/uso terapêutico , Mastectomia Segmentar/métodos , Estadiamento de Neoplasias/economia , Palpação/economia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/terapia , Análise Custo-Benefício , Feminino , Seguimentos , Humanos , Mastectomia Segmentar/economia , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Palpação/métodos , Cintilografia , Estudos Retrospectivos
15.
Int. braz. j. urol ; 47(1): 120-130, Jan.-Feb. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1134327

RESUMO

ABSTRACT Aim: To evaluate the radiotherapy (RT) effect in the pelvic floor muscles (PFM) function in men with prostate cancer (PC). Materials and Methods: A cross-sectional study included three groups of patients with PC and RT indication: 1) Pre-RT group: evaluated before the beginning of RT; 2) Acute group: evaluated between six months and one year after RT; 3) Late Group: evaluated between two and a half years and four years post-RT. PFM assessment was divided into: a) functional assessment through the digital anal palpation (Modified Oxford Scale) and surface electromyography (sEMG) with anal probe; b) anatomical assessment by pelvic magnetic resonance imaging (MRI) with thickness measurements of levator ani muscle and pelvic specific parameters at rest and under Valsalva maneuver. We used Student t test, considering as significant p <0.05. Results: Thirty-three men were assessed: Pre-RT (n=12); Acute (n=10) and Late (n=11) groups. PFM functional assessment showed Late group with lower electromyographic activity, especially in the sustained contractions when compared to the Pre-RT (p=0.003) and Acute groups (p=0.006). There was no significant difference between groups in MRI. Conclusion: PFM functional assessment showed a decrease in sEMG activity in the Late group post-RT. Most of the sample (72.7%) did not know how to actively contract the PFM or had a weak voluntary contraction when assessed by digital anal palpation. Also, these patients presented higher prevalence of pelvic complaints. No changes were observed in the morpho-functional parameters evaluated by MRI, except the measurement of the membranous urethra length when comparing Pre-RT Group and Acute and Late Groups.


Assuntos
Humanos , Masculino , Próstata/imunologia , Diafragma da Pelve/diagnóstico por imagem , Palpação , Imageamento por Ressonância Magnética , Estudos Transversais , Eletromiografia , Contração Muscular
16.
J Altern Complement Med ; 27(3): 263-272, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33395535

RESUMO

Background: The World Health Organization benchmarks for osteopathic training consider cranial osteopathy as an important manual skill. Studies of cranial manual therapy have exhibited poor reliability. The aim of this study was to investigate the inter-rater reliability of the manual mobility tests of the spheno-occipital synchondrosis (SOS), and the temporal, parietal, and frontal bones, as assessed in osteopathic manual therapy. Methods: Twenty-one adults were assessed on a single day by three experienced osteopaths using a standard assessment protocol. Before data collection, the osteopaths participated in a consensus training, which included establishing the criteria for identifying a cranial bone mobility restriction; the application of the seven-step palpation method; a pretesting practice; a fine-tuning palpation training; and a calibration period before the assessment of the subjects. Three subjects were assessed simultaneously with the evaluators rotating to assess each subject. The evaluators were blinded to the subject by a curtain, and each other's assessments. Each bone was rated as restricted or not restricted. The authors applied the Landis and Koch classification to describe the magnitude of inter-rater reliability. Results: Moderate reliability was established for a lateral strain of the SOS (Fleiss' generalized kappa 0.48), substantial reliability was established for the other SOS strain patterns (Fleiss' generalized kappa 0.62-0.75), and almost perfect reliability for temporal, parietal, and frontal bone (Fleiss' generalized kappa 0.81-0.96). Conclusion: The results demonstrate consistency when three experienced osteopaths evaluate cranial bone mobility restrictions. The results highlight the importance of consensus training and rigorous methodology in manual therapy reliability studies.


Assuntos
Cabeça/fisiologia , Articulações/fisiologia , Osteopatia/métodos , Osteopatia/normas , Crânio/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Palpação , Reprodutibilidade dos Testes , Adulto Jovem
17.
Int Braz J Urol ; 47(1): 120-130, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33047917

RESUMO

AIM: To evaluate the radiotherapy (RT) effect in the pelvic floor muscles (PFM) function in men with prostate cancer (PC). MATERIALS AND METHODS: A cross-sectional study included three groups of patients with PC and RT indication: 1) Pre-RT group: evaluated before the beginning of RT; 2) Acute group: evaluated between six months and one year after RT; 3) Late Group: evaluated between two and a half years and four years post-RT. PFM assessment was divided into: a) functional assessment through the digital anal palpation (Modified Oxford Scale) and surface electromyography (sEMG) with anal probe; b) anatomical assessment by pelvic magnetic resonance imaging (MRI) with thickness measurements of levator ani muscle and pelvic specific parameters at rest and under Valsalva maneuver. We used Student t test, considering as significant p <0.05. RESULTS: Thirty-three men were assessed: Pre-RT (n=12); Acute (n=10) and Late (n=11) groups. PFM functional assessment showed Late group with lower electromyographic activity, especially in the sustained contractions when compared to the Pre-RT (p=0.003) and Acute groups (p=0.006). There was no significant difference between groups in MRI. CONCLUSION: PFM functional assessment showed a decrease in sEMG activity in the Late group post-RT. Most of the sample (72.7%) did not know how to actively contract the PFM or had a weak voluntary contraction when assessed by digital anal palpation. Also, these patients presented higher prevalence of pelvic complaints. No changes were observed in the morpho-functional parameters evaluated by MRI, except the measurement of the membranous urethra length when comparing Pre-RT Group and Acute and Late Groups.


Assuntos
Diafragma da Pelve , Próstata , Estudos Transversais , Eletromiografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Contração Muscular , Palpação , Diafragma da Pelve/diagnóstico por imagem , Próstata/diagnóstico por imagem
18.
Int Urogynecol J ; 32(5): 1237-1245, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33219823

RESUMO

INTRODUCTION AND HYPOTHESIS: We hypothesized that anatomical changes in the pelvic floor muscles (PFM) could be detected using four-dimensional translabial ultrasound (4D TLUS) in patients with cervical (CC) or endometrial cancer (EC) who underwent pelvic radiotherapy (RT) as digital palpation may present sensitivity limitations. METHODS: This was a cross-sectional study that included 64 women (26 with CC and 38 with EC). PFM function was assessed by digital palpation, grading muscle strength according to the Modified Oxford Scale and by 4D TLUS. Ultrasonographic variables were: levator plate angle, hiatal area, puborectalis muscle thickness, puborectalis strain and levator ani muscle integrity. These variables were also correlated with clinical and sociodemographic data from all these patients. A 5% significance level was adopted. RESULTS: When assessed by digital palpation, no significant difference was found in PFM strength between women with CC and those with EC (p = 0.747). However, when assessed by 4D TLUS, women with CC presented greater thickening of the left (p = 0.039) and right (p = 0.014) lower portion of the puborectalis muscle during PFM contraction compared to those with EC. After pooling the groups, higher cancer staging (p = 0.028) was associated with smaller narrowing in the symphysis-levator distance, and shorter RT finishing duration (< 60 months) was associated with higher thickening in the left (p = 0.029) and right (p = 0.013) upper portion of the puborectalis muscle during PFM contraction as well as a shorter menopause duration (p = 0.007 and p = 0.002, respectively). CONCLUSIONS: Anatomical changes in the puborectalis muscle during PFM contraction were detected by 4D TLUS within gynecological cancer patients after pelvic RT.


Assuntos
Neoplasias do Endométrio , Diafragma da Pelve , Estudos Transversais , Feminino , Humanos , Contração Muscular , Força Muscular , Palpação , Diafragma da Pelve/diagnóstico por imagem , Ultrassonografia
20.
BMC Pregnancy Childbirth ; 20(1): 391, 2020 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-32631265

RESUMO

BACKGROUND: The purpose of this study was to compare the reliability and reproducibility of the traditional qualitative method of assessing uterine cervical stiffness with those of a quantitative method using a novel device based on the aspiration technique. METHODS: Five silicone models of the uterine cervix were created and used to simulate different cervical stiffnesses throughout gestation. The stiffness of the five cervix models was assessed both by digital palpation (firm, medium and soft) and with the Pregnolia System. Five self-trained participants conducted the device-based assessment, whereas 63 obstetricians and midwives, trained in digital palpation, conducted the cervical palpation. RESULTS: The results of the two methods were analyzed in terms of inter-and intra-observer variability. For digital palpation, there was no common agreement on the assessment of the stiffness, except for the softest cervix. When assessing the same cervix model for a second time, 76% of the obstetricians and midwives disagreed with their previous assessment. In contrast, the maximum standard deviation for the device-based stiffness assessment for intra- and inter-observer variability was 3% and 3.4%, respectively. CONCLUSIONS: This study has shown that a device based on the aspiration technique provides obstetricians and midwives with a method for objectively and repeatably assess uterine cervical stiffness, which can eliminate the need to rely solely on a subjective interpretation, as is the case with digital palpation.


Assuntos
Maturidade Cervical/fisiologia , Colo do Útero/fisiologia , Palpação/métodos , Sucção/instrumentação , Feminino , Humanos , Modelos Anatômicos , Variações Dependentes do Observador , Gravidez , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA