Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J AOAC Int ; 106(5): 1165-1179, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37341634

RESUMO

BACKGROUND: Antihypertensives bisoprolol fumarate (BIS) and perindopril arginine (PER) were simultaneously determined in their pure, bulk, and combined tablet dosage form. OBJECTIVE: This study develops a novel, reproducible, and accurate Reversed phase high-performance liquid chromatography (RP-HPLC) and Reversed phase ultra-performance liquid chromatography (RP-UPLC) with photodiode array detection techniques, which were then applied to in vitro dissolution studies. METHODS: The first RP-HPLC method relied on isocratic elution using a mobile phase of methanol-0.05 M phosphate buffer pH 2.6 (1 + 1, by volume), and separation was performed using a Thermo Hypersil C8 column (150 mm × 4.6 mm, 5 µm). Ion-pair UPLC was the second method. An acceptable resolution was achieved using an RP-C18 chromatographic column, Agilent Eclipse (100 × 2.1 mm, 1.7 µm), with a mobile phase containing 0.005 M sodium 1-heptane sulfonate-triethylamine (64 + 1 + 35, by volume), adjusted with phosphoric acid to a pH of 2.0. RP-HPLC used a 1.0 mL/min flow rate, while UPLC used 0.5 mL/min, and the two methods used detection at 210 nm. RESULTS: Calibration curves of BIS and PER were linear for RP-HPLC and RP-UPLC methods at 0.5-15 and 0.5-40 µg/mL, respectively. BIS and PER had RP-UPLC LODs of 0.22 and 0.10 µg/mL, respectively, and LOQs of 0.68 and 0.31 µg/mL, respectively. As a result, the approach has been effectively applied to in vitro dissolution testing for drugs in generic and reference products, showing that the two products are comparable. The Six Sigma approach was implemented to compare the recommended and United States Pharmacopeia (USP) procedures, which both exhibited process capability index (Cpk) >1.33. A content uniformity test demonstrated that the drugs in their dosage form met the acceptance limit (85-115%). The degradation products were reliably distinguished from pure drugs for a range of retention times. CONCLUSION: In their commercial drug product, the proposed method could be used in QC laboratories for concurrent testing, content uniformity, and in vitro dissolution investigations of BIS and PER. The methods were successfully validated per International Council for Harmonisation (ICH) guidelines. HIGHLIGHTS: This study is innovative since it is the first to establish and validate specific and reproducible UPLC and HPLC methods for the concurrent quantitation of the studied drugs in their binary mixture and application to lean Six Sigma, content uniformity, and comparative dissolution approaches.


Assuntos
Bisoprolol , Perindopril , Arginina , Bisoprolol/análise , Perindopril/análise , Solubilidade , Gestão da Qualidade Total
2.
Anal Bioanal Chem ; 409(26): 6141-6148, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28842738

RESUMO

A first of its kind, simple, rapid, and sensitive liquid chromatography mass spectrometry (LC-MS/MS) method was developed and validated for quantification of perindopril and perindoprilat in both human plasma and breast milk. The analytes and internal standards (phenazone and acetyl salicylic acid) were extracted from biological matrices by protein precipitation. A Phenomenex® C-18 column was used to provide an appropriate chromatographic separation of the analytes, followed by detection with tandem mass spectrometry. Gradient chromatographic and mass spectrometric detection conditions with mobile phases (A: 5% methanol + 0.1% formic acid in water v/v, and B: 95% methanol + 0.1% formic acid in water v/v) were developed to achieve a LOQ of 0.5 ng/mL in both human plasma and milk. The method was suitable of evaluating clinical samples. The mass transition was followed as m/z 369.10/172.00 for perindopril, m/z 339.00/168.10 for perindoprilat, m/z 188.90/55.95 for phenazone, and m/z 179.04/137.02 for acetyl salicylic acid. The developed method was optimized and validated with a linear range of 0.1-200 ng/mL (r 2 = better than 0.99 for both perindopril and perindoprilat). The precision and accuracy values were within 15% CV. The overall recovery of the analytes was 80-110%. The method has good specificity and repeatability. Stability studies were conducted in both human plasma and bovine milk for up to 3 months, at the storage conditions of 25, 4, and -80 °C.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/análise , Inibidores da Enzima Conversora de Angiotensina/sangue , Indóis/análise , Indóis/sangue , Leite Humano/química , Perindopril/análise , Perindopril/sangue , Aleitamento Materno , Cromatografia Líquida/economia , Cromatografia Líquida/métodos , Feminino , Humanos , Limite de Detecção , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/economia , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA