1.
JBJS Rev ; 12(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38446912

RESUMO

BACKGROUND: Distal femur fractures are known to have challenging nonunion rates. Despite various available treatment methods aimed to improve union, optimal interventions are yet to be determined. Importantly, there remains no standard agreement on what defines radiographic union. Although various proposed criteria of defining radiographic union exist in the literature, there is no clear consensus on which criteria provide the most precise measurement. The use of inconsistent measures of fracture healing between studies can be problematic and limits their generalizability. Therefore, this systematic review aims to identify how fracture union is defined based on radiographic parameters for surgically treated distal femur fractures in current literature. METHODS: In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, Medline, EMBASE, Cochrane Central Register of Controlled Trials, and Web of Science Core Collection databases were searched from inception to October 2022. Studies that addressed surgically treated distal femur fractures with reported radiographic union assessment were included. Outcomes extracted included radiographic definition of union; any testing of validity, reliability, or responsiveness; reported union rate; reported time to fracture union; and any functional outcomes correlated with radiographic union. RESULTS: Sixty articles with 3,050 operatively treated distal femur fractures were included. Operative interventions included lateral locked plate (42 studies), intramedullary nail (15 studies), dynamic condylar screw or blade plate (7 studies), dual plate or plate and nail construct (5 studies), distal anterior-posterior/posterior-anterior screws (1 study), and external fixation with a circular frame (1 study). The range of mean follow-up time reported was 4.3 to 44 months. The most common definitions of fracture union included "bridging or callus formation across 3 of 4 cortices" in 26 (43%) studies, "bony bridging of cortices" in 21 (35%) studies, and "complete bridging of cortices" in 9 (15%) studies. Two studies included additional assessment of radiographic union using the Radiographic Union Scale in Tibial fracture (RUST) or modified Radiographic Union Scale in Tibial fracture (mRUST) scores. One study included description of validity, and the other study included reliability testing. The reported mean union rate of distal femur fractures was 89% (range 58%-100%). The mean time to fracture union was documented in 49 studies and found to be 18 weeks (range 12-36 weeks) in 2,441 cases. No studies reported correlations between functional outcomes and radiographic parameters. CONCLUSION: The current literature evaluating surgically treated distal femur fractures lacks consistent definition of radiographic fracture union, and the appropriate time point to make this judgement is unclear. To advance surgical optimization, it is necessary that future research uses validated, reliable, and continuous measures of radiographic bone healing and correlation with functional outcomes. LEVEL OF EVIDENCE: Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas Femorais Distais , Fraturas da Tíbia , Humanos , Reprodutibilidade dos Testes , Placas Ósseas , Parafusos Ósseos
2.
Eur J Orthop Surg Traumatol ; 34(1): 659-671, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37684357

RESUMO

BACKGROUND: The optimal modality to surgically treat significant bone loss of distal femur remains inconclusive. The objectives of the present study were to assess the mechanical performance of nonvascularized fibular graft (NVFG) with locking screw fixation in distal femur fixation construct by finite element analysis and to retrospectively describe the outcomes of the present technique in clinical cases. METHODS: Four constructs which the fractured femur was stabilized by LCP-DF alone, dual plating, LCP-DF combined with NVFG, and LCP-DF combined with NVFG (LCP-DF-NVFG-S) with locking screw were assessed the biomechanical performance under physiological loads. For the clinical case series, 12 patients with open intercondylar fracture with metaphyseal bone loss of distal femur were operated by LCP-DF-NVFG-S. The collected data included fracture consolidation, length of NVFG, perioperative complications and objective clinical results. RESULTS: LCP-DF-NVFG-S demonstrated lower implant equivalent von Mises stress (EQV) stress and better fracture stability than other constructs. A locking screw presented its essence in maintaining the NVFG in the required position and subsequently enhancing the fracture stability. In regard to the clinical series, all fractures were consolidated with an average duration of 27.8 weeks (range 20-32). An average NVFG length was 7.8 cm (range 6-12). No perioperative complication was demonstrated. By the Knee Society score, 1 was considered to be excellent, 9 to be good and 2 to be poor. CONCLUSION: Based on the results of mechanical assessment and case series, LCP-DF-NVFG-S can be an effective technique in the management of metaphyseal bone loss of distal femur.


Assuntos
Placas Ósseas , Fraturas do Fêmur , Humanos , Estudos Retrospectivos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fraturas do Fêmur/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fenômenos Biomecânicos
3.
Eur J Orthop Surg Traumatol ; 34(2): 959-965, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37779131

RESUMO

PURPOSE: To analyze differences in union, complication rates and cost from surgical fixation of distal fibula fractures with fibular plating implants. METHODS: In total, 380 adult patients from 2012 to 2015 treated with 12 fibular plates from 4 different manufacturers utilized by 9 surgeons were retrospectively reviewed. They were stratified into a conventional one-third tubular fibular plate group, pre-contoured anatomic locking plate group, or a heterogeneous group including 3.5-mm reconstruction, one-third tubular locking, composite, and limited compression plates. The outcomes included failure of fixation, deep infection requiring debridement, time to union, anatomic reduction, superficial infection, hardware removal, and post-traumatic arthritis. Plate and screw costs were calculated from hospital billing records. RESULTS: Pre-contoured locking plates were used in older, female patients with a greater number of comorbidities. Open injuries and OTA 44B fractures were more likely to be an indication for pre-contoured plates. There was no difference noted in time to union between the different plating groups. Risk factors for deep infection requiring debridement included a history of tobacco use, open fractures, and pre-contoured locking plates relative to the conventional plating group. The pre-contoured plating group was on average $586 more expensive compared to the conventional group. CONCLUSION: Pre-contoured locking plates achieved similar radiographic outcomes compared to conventional plates with an increased risk of complications and higher cost. Surgeons should consider their choice of implant based on the patient's fracture pattern, underlying comorbidities, and risk for infection.


Assuntos
Fraturas do Tornozelo , Adulto , Humanos , Feminino , Idoso , Fraturas do Tornozelo/cirurgia , Fraturas do Tornozelo/etiologia , Fíbula/lesões , Estudos Retrospectivos , Fixação Interna de Fraturas/efeitos adversos , Custos e Análise de Custo , Placas Ósseas/efeitos adversos , Resultado do Tratamento
4.
BMC Musculoskelet Disord ; 24(1): 962, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38082305

RESUMO

BACKGROUND: Open distal tibial fractures pose significant challenges regarding treatment options and patient outcomes. This retrospective single-centre study aimed to compare the stability, clinical outcomes, complications, and financial implications of two surgical interventions, namely the external locking plate and the combined frame external fixator, to manage open distal tibial fractures. METHODS: Forty-four patients with distal open tibial (metaphyseal extraarticular) fractures treated between 2020 and 2022 were selected and formed into two main groups, Group A and Group B. Group A (19 patients) are patients that underwent treatment using the external locking plate technique, while Group B (25 patients) received the combined frame external fixator approach. Age, gender, inpatient stay, re-operation rates, complications, functional recovery (measured by the Johner-Wrush score), pain ratings (measured by the Visual Analogue Scale [VAS]), and cost analyses were evaluated for each group. Statistical analyses using SPSS were conducted to compare the outcomes between the two groups. RESULTS: The research found significant variations in clinical outcomes, complications, and cost consequences between Group A and Group B. Group A had fewer hospitalisation periods (23.687.74) than Group B (33.5619.47). Re-operation rates were also considerably lower in Group A (26.3%) than in Group B (48%), owing to a greater prevalence of pin-tract infections and subsequent pin loosening in the combination frame external fixator group. The estimated cost of both techniques was recorded and analysed with the locking average of 26,619.69 ± 9,602.352 and the combined frame average of 39,095.64 ± 20,070.077. CONCLUSION: This study suggests that although the two approaches effectively manage open distal tibia fractures, the locking compression plate approach (Group A) has an advantage in treating open distal tibia fractures. Shorter hospitalisation times, reduced re-operation rates, and fewer complications will benefit patients, healthcare systems, and budget allocation. Group A's functional recovery results demonstrate the locking plate technique's ability to improve recovery and patient quality of life. According to the cost analysis, the locking plate technique's economic viability and cost-effectiveness may optimise healthcare resources for open distal tibia fractures. These findings might improve patient outcomes and inform evidence-based orthopaedic surgery.


Assuntos
Fraturas Expostas , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Fixadores Externos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixação de Fratura/efeitos adversos , Fixação de Fratura/métodos , Fraturas Expostas/cirurgia , Placas Ósseas , Resultado do Tratamento
5.
J Bone Joint Surg Am ; 105(23): 1886-1896, 2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-37967070

RESUMO

BACKGROUND: Prior studies have highlighted lower rates of reoperation if fixation of a displaced midshaft clavicle fracture is performed with dual plating (DP) compared with single plating (SP). Despite higher initial costs associated with the DP construct, the observed reduction in secondary surgeries compared with the SP construct may make it a more cost-effective treatment option. The objective of this study was to assess the cost-effectiveness of DP compared with SP in patients with operatively indicated displaced midshaft clavicle fractures. METHODS: We developed a decision tree to model the occurrence of postoperative complications (acute hardware complications, wound healing issues, deep infection, nonunion, and symptomatic hardware) associated with secondary surgeries. Complication-specific risk estimates were pooled for both plating techniques using the available literature. The time horizon was 2 years, and the analysis was conducted from the health-care payer's perspective. The costs were estimated using direct medical costs, and the benefits were measured in quality-adjusted life-years (QALYs). We assumed that DP would be $300 more expensive than SP initially. We conducted probabilistic and 1-way sensitivity analyses. RESULTS: The model predicted reoperation in 6% of patients in the DP arm compared with 14% of patients in the SP arm. In the base case analysis, DP increased QALYs by 0.005 and costs by $71 per patient, yielding an incremental cost-effectiveness ratio (ICER) of $13,242 per QALY gained. The sensitivity analysis demonstrated that the cost-effectiveness of DP was driven by the cost of the index surgery, risk of symptomatic hardware, and nonunion complications with SP and DP. At a willingness-to-pay threshold of $100,000 per QALY gained, 95% of simulations suggested that DP was cost-effective compared with SP. CONCLUSIONS: When indicated, operative management of displaced midshaft clavicle fractures using DP was found to be cost-effective compared with SP. Despite its higher initial hardware costs, DP fixation appears to offset its added costs with greater health utility via lower rates of reoperation and improved patient quality of life. LEVEL OF EVIDENCE: Economic and Decision Analysis Level II . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Análise de Custo-Efetividade , Fraturas Ósseas , Humanos , Clavícula/cirurgia , Qualidade de Vida , Fraturas Ósseas/terapia , Fixação Interna de Fraturas/métodos , Custos de Cuidados de Saúde , Placas Ósseas , Análise Custo-Benefício
6.
Sensors (Basel) ; 23(16)2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37631692

RESUMO

A three-dimensional motion capture system (MoCap) and the Garmin Running Dynamics Pod can be utilised to monitor a variety of dynamic parameters during running. The present investigation was designed to examine the validity of these two systems for determining ground contact times while running in place by comparing the values obtained with those provided by the bilateral force plate (gold standard). Eleven subjects completed three 20-s runs in place at self-selected rates, starting slowly, continuing at an intermediate pace, and finishing rapidly. The ground contact times obtained with both systems differed significantly from the gold standard at all three rates, as well as for all the rates combined (p < 0.001 in all cases), with the smallest mean bias at the fastest step rate for both (11.5 ± 14.4 ms for MoCap and -81.5 ± 18.4 ms for Garmin). This algorithm was developed for the determination of ground contact times during normal running and was adapted here for the assessment of running in place by the MoCap, which could be one explanation for its lack of validity. In conclusion, the wearables developed for monitoring normal running cannot be assumed to be suitable for determining ground contact times while running in place.


Assuntos
Captura de Movimento , Corrida , Humanos , Algoritmos , Placas Ósseas
7.
PLoS One ; 18(8): e0290250, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37616204

RESUMO

Tackling water scarcity is a significant challenge due to the rapid increase in the global population, which is raising concern for the supply of fresh water. high demand of fresh water leading to a failure in meeting the demand for fresh water. This study aims to investigate the feasibility of an efficient single-slope solar still with an aluminum-finned plate absorber and internal and external reflectors to address water scarcity. Energy, exergy, economic and environmental analyses (6E) were undertaken to deeply analyze its impact on the environment. The maximum energy and exergy efficiency achieved was 60.19% and 21.57%, respectively, at a 2cm depth. The use of both external and internal reflectors assisted in the highest productivity of 7.02 liters. The cost of 0.033$/liter was obtained for a lifetime of 10 years for the optimal system. The payback time in terms of energy and exergy for the optimal system is 0.88 and 2.23 years, respectively. Furthermore, sustainability and sensitivity (2S) analysis were also performed to assess the system's current and future feasibility. The total price for carbon dioxide mitigation during the solar still lifetime was $346.7, which represents the cost saving achieved with the installation of the optimal system.


Assuntos
Alumínio , Placas Ósseas , Fenômenos Físicos , Dióxido de Carbono , Água Doce
8.
Sensors (Basel) ; 23(10)2023 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-37430500

RESUMO

Balance assessment, or posturography, tracks and prevents health complications for a variety of groups with balance impairment, including the elderly population and patients with traumatic brain injury. Wearables can revolutionize state-of-the-art posturography methods, which have recently shifted focus to clinical validation of strictly positioned inertial measurement units (IMUs) as replacements for force-plate systems. Yet, modern anatomical calibration (i.e., sensor-to-segment alignment) methods have not been utilized in inertial-based posturography studies. Functional calibration methods can replace the need for strict placement of inertial measurement units, which may be tedious or confusing for certain users. In this study, balance-related metrics from a smartwatch IMU were tested against a strictly placed IMU after using a functional calibration method. The smartwatch and strictly placed IMUs were strongly correlated in clinically relevant posturography scores (r = 0.861-0.970, p < 0.001). Additionally, the smartwatch was able to detect significant variance (p < 0.001) between pose-type scores from the mediolateral (ML) acceleration data and anterior-posterior (AP) rotation data. With this calibration method, a large problem with inertial-based posturography has been addressed, and wearable, "at-home" balance-assessment technology is within possibility.


Assuntos
Aceleração , Benchmarking , Humanos , Idoso , Análise de Componente Principal , Calibragem , Placas Ósseas
9.
Injury ; 54(8): 110835, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37321881

RESUMO

OBJECTIVE: The study aimed to explore the effect of differing volar locking plate (VLP) prominence on the median nerve (MN) in distal radius fracture (DRF) with ultrasound assistance to guide clinical treatment. METHODS: Forty-four patients who received VLP for DRF at our department were admitted and followed-up between January 2019 and May 2021. Different plate positions were graded using Soong classification; 13 were Grade 0, 18 were Grade 1, and 13 were Grade 2. The MN parameters at different wrist positions in patients with different Soong grades were measured with ultrasound assistance, including the median nerve cross-sectional area (MNCSA), diameter in the radial-ulnar direction (D1), and diameter in the dorsal-palmar direction (D2). The sensation in the affected finger and grip strength were collected at follow-up, scored using the Disabilities of the Arm, Shoulder, and Hand (DASH) scale to determine function, and statistically analysed. RESULTS: The MNCSA differed significantly across Soong grades. The MNCSA at the flexed, neutral, and extended wrist positions was smallest at Grade 0 and largest at Grade 2 (P < 0.05), and that at the neutral position was not significantly different between Grades 1 and 2 (P > 0.05). There was no significant interaction between the wrist positions and Soong grade (P > 0.05). The differences in D1 and D2 among different Soong grades were not statistically significant (P > 0.05). There were no statistical differences in grip strength, DASH, and sensation among different Soong grades (P > 0.05). CONCLUSIONS: Differing plate protrusions in DRF treatment did not cause clinical symptoms during follow-up; however, excessive plate protrusion (Soong Grade 2) increased the cross-sectional area of the MN. We recommend placing the plate as proximal as possible during VLP treatment of DRFs to avoid excessive bulges affecting the MN.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Nervo Mediano/diagnóstico por imagem , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Articulação do Punho/diagnóstico por imagem , Placas Ósseas , Ultrassonografia , Fixação Interna de Fraturas , Amplitude de Movimento Articular/fisiologia
10.
J Hand Surg Am ; 48(9): 875-885, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37389496

RESUMO

PURPOSE: Volar locking plate fixation of distal radius fractures is a common orthopedic procedure and should be mastered by graduating orthopedic residents. Surgical education is transitioning from a traditional time-based approach to competency-based medical education. Valid and objective assessment is essential for successful transition. The purpose of this study was to develop a comprehensive, procedure-specific assessment tool to evaluate technical competence in volar locking plate osteosynthesis of a distal radius fracture. METHODS: International orthopedic/trauma experts involved in resident education participated as panelists in a four-round online Delphi process to reach consensus on the content of the assessment tool. Round 1 was an item-generating round, in which the panelists identified potential assessment parameters. In round 2, the panelists rated the importance of each suggested assessment parameter and reached consensus on which to include in the assessment tool. Round 3 yielded specific assessment score intervals for specific bone and fracture models and is not reported in this study. In round 4, the panelists assigned weights to the assessment parameters on a 1-10 scale to determine how each parameter should have an impact on the overall results. RESULTS: Eighty-seven surgeons, representing 42 countries, participated in the study. Round 1 resulted in 45 assessment parameters, grouped into five procedural steps. After round 2, the number of parameters was reduced to 39. After the final round, an additional parameter was removed and weights were assigned to the remaining parameters. CONCLUSIONS: Using a systematic methodology, a preliminary assessment tool to evaluate technical competence in distal radius fracture fixation was developed. A consensus of international experts supports the content validity of the assessment tool. CLINICAL RELEVANCE: This assessment tool represents the first step in the evidence-based assessment essential for competency-based medical education. Before implementation, further studies exploring validity of variations of the assessment tool in different educational contexts are required.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Técnica Delphi , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas
11.
Arch Orthop Trauma Surg ; 143(8): 5007-5014, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37005933

RESUMO

INTRODUCTION: Arthroscopically assisted coracoclavicular (CC) ligament fixation techniques have been promoted as providing superior outcomes for the treatment of acute high-grade acromioclavicular joint (ACJ) dislocations. Nevertheless, there is a lack of high-level evidence for clinically relevant benefits. At our institute, orthopaedic surgeons use an arthroscopically assisted coracoclavicular ligament fixation technique (DB), while general trauma surgeons use a clavicular hook plate (cHP) technique. The aim of the study was to compare clinical outcomes, complication rates, and costs between the two groups. MATERIALS AND METHODS: The hospital database was searched for patients treated for acute traumatic high-grade (Rockwood Typ ≥ III) ACJ dislocation using either a cHP or arthroscopically assisted DB technique between 2010 and 2019. Seventy-nine patients could be included (56 patients in the cHP group and 23 in the DB group). QuickDASH scores, subjective shoulder value (SSV) scores, pain scores (numerical pain rating scale 10), and complication rates were retrospectively collected through phone interviews and by screening patient charts as well as surgical reports. Costs per patient were obtained from the hospital's accounting system. RESULTS: Mean follow-up was 54 ± 33.7 and 45 ± 21.7 months in the cHP and DB group, respectively. QuickDASH and SSV scores did not differ, but patients in the cHP group reported significantly lower pain scores (p = 0.033). More patients reported hypertrophic or disturbing scars (p = 0.49) and sensibility disturbances (p = 0.007) in the cHP group. Three patients suffered from a frozen shoulder in the DB group (p = 0.023). CONCLUSION: Patient-reported outcomes are excellent after long-term follow-up for both techniques. There are no clinically relevant differences in clinical outcome scores based on our results and a review of the literature. Both techniques certainly have their benefits regarding secondary outcome measures. LEVEL OF CLINICAL EVIDENCE: Level 3, retrospective cohort study.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Luxação do Ombro , Articulação Acromioclavicular/cirurgia , Articulação Acromioclavicular/lesões , Placas Ósseas , Luxações Articulares/cirurgia , Dor , Estudos Retrospectivos , Luxação do Ombro/cirurgia , Resultado do Tratamento , Humanos
12.
BMC Musculoskelet Disord ; 24(1): 308, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37076821

RESUMO

INTRODUCTION: There is a great debate on the routine use of open reduction and internal fixation (ORIF) for midshaft clavicle fractures, and one concern is the adverse events after ORIF, such as implant removal after bone union. In this retrospective study, we assessed the incidence, risk factors, management and outcomes of refracture after plate removal of midshaft clavicle fractures after bone union. MATERIALS AND METHODS: Three hundred fifty-two patients diagnosed with acute midshaft clavicle fractures who had complete medical records from primary fractures to refracture were recruited. Details of imaging materials and clinical characteristics were carefully reviewed and analysed. RESULTS: The incidence rate of refracture was 6.5% (23/352), and the average interval from implant removal to refracture was 25.6 days. Multivariate analysis showed that the risk factors were Robinson type-2B2 and fair/poor reduction. Females were 2.4 times more likely to have refracture, although it was not significant in multivariate analysis (p = 0.134). Postmenopausal females with a short interval (≤ 12 months) from primary surgery to implant removal had a significant risk for refracture. Tobacco use and alcohol use during bone healing were potential risk factors for male patients, although they were not significant in multivariate analysis. Ten patients received reoperation with or without bone graft, and they had a higher rate of bone union than 13 patients who refused reoperation. CONCLUSION: The incidence of refracture following implant removal after bone union is underestimated, and severe comminute fractures and unsatisfactory reduction during primary surgery are risk factors. Implant removal for postmenopausal female patients is not recommended due to a high rate of refracture.


Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Humanos , Masculino , Feminino , Incidência , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Estudos Retrospectivos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/cirurgia , Fatores de Risco , Placas Ósseas/efeitos adversos , Resultado do Tratamento
13.
PLoS One ; 18(4): e0283946, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37023069

RESUMO

BACKGROUND AND PURPOSE: Non-operative treatment is the most common treatment option for older patients with distal radius fracture (DRF). Traditionally, wrists have been placed in volar-flexion and ulnar deviation position (VFUDC). In recent years, there has been a trend towards using a functional position cast (FC). However, long-term results for these different casting positions are lacking. PATIENTS AND METHODS: This randomized, controlled, prospective study evaluates the functional results and costs of the 2 casting positions in patients 65 and older with DRF. Primary end point in this study was Patient-Reported Wrist Evaluation (PRWE) at 24 months, and secondary end points were cost-effectiveness of treatment, health-related quality of life measurement (15D), short version of Disabilities of arm, shoulder and hand score (QuickDASH), and VAS at 24 months. The trial was registered in ClinicalTrials.gov (NCT02894983, https://clinicaltrials.gov/ct2/show/NCT02894983). RESULTS: We enrolled 105 patients, of which 81 (77%) continued until 24-month follow-up. 8 patients (18%) were operated in the VFUDC group and 4 (11%) in the FC group. Patients in the VFUDC group also received more frequent physical therapy. The difference in PRWE score between the VFUDC and FC groups at 24 months was -4.31. The difference in the cost of treatment per patient was €590. Both findings favored FC. INTERPRETATION: We found a slight, but consistent difference in the functional results between groups. These results suggest that VFUDC is not superior to FC when treating Colles' type DRF. Cost analysis revealed overall costs in the VFUDC group are nearly double those in the FC group, mostly due to more physical therapy, additional visits to hospital, and additional examinations. Therefore, we recommend FC in older patients with Colles' type DRF.


Assuntos
Fratura de Colles , Fraturas do Rádio , Fraturas do Punho , Humanos , Idoso , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Moldes Cirúrgicos , Fratura de Colles/cirurgia , Placas Ósseas , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos
14.
Int Orthop ; 47(1): 193-199, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36264303

RESUMO

INTRODUCTION: The results of surgical techniques vary depending on the level of the surgeon's experience. The level of expertise can be evaluated quantitatively or qualitatively. In this study, we evaluated the duration of the procedure and the size of the incision of minimally invasive fixation of distal radius fractures as a means of grading expertise and surgical performance. The null hypothesis of our study was that the level of expertise did not match the level of performance. MATERIAL AND METHODS: The study included 52 surgeons split in five levels of expertise who had performed 467 minimally invasive fixations of distal radius fractures. The performance of the surgeons in terms of duration of the procedure and size of the incision were scored according to the five levels of surgical experience using four different methodologies: clinical (setting limits compared to data found in literature), statistical (setting statistical limits of comparison in percentiles (20th, 40th, 60th, 80th) for each of the two parameters measured), arithmetical (setting limits compared to equal intervals for each of the 2 variables), and success rate (setting a threshold for each of the 2 variables). RESULTS: Our results showed a great disparity between levels of experience depending on the method used. The scores for levels 1 and 2 were 72% for expertise, 13% for performance according to the clinical method, 75% for the statistical method, 0% for the arithmetical method, and 57% according the success rate. The rate of level 3 was 23% for expertise, 41% for performance by the clinical method, 17% by the statistical method, 17% by the arithmetical method, and 15% by the success rate. The rates of levels 4 and 5 were 5% for expertise, 46% for performance clinical method, 8% by the statistical method, 83% by the arithmetical method, and 28% by the success rate. DISCUSSION: The null hypothesis of our study was confirmed by the results which show that there was no correlation between levels of expertise and performance. The clinical method of assessment appears to reflect best the true level of performance of the surgeon. CONCLUSION: Publications reporting the results of a surgical technique for a given pathology should always mention the level of performance as measured on a clinical scale.


Assuntos
Fraturas do Rádio , Cirurgiões , Fraturas do Punho , Humanos , Fixação Interna de Fraturas/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Placas Ósseas , Fraturas do Rádio/cirurgia , Resultado do Tratamento
15.
Clin Spine Surg ; 36(7): E317-E323, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35943872

RESUMO

STUDY DESIGN: This was a retrospective cohort study. OBJECTIVE: To characterize the variability in cost for anterior cervical discectomy and fusion (ACDF) constructs and to identify key predictors of procedural cost. SUMMARY OF BACKGROUND DATA: ACDF is commonly performed for surgical treatment of cervical radiculopathy and myelopathy. Numerous biomechanical constructs and graft/biological options are available, with most demonstrating relatively equivalent clinical results. Despite the substantial focus on value in spine care, the differences and contributions to procedural cost in ACDF have not been well defined. MATERIALS AND METHODS: We evaluated the records of patients who underwent a single level ACDF from 2016 to 2020 at 4 hospitals in a major metropolitan area. We abstracted demographics, insurance status, operative time, diagnosis, surgeon, institution, and components of procedural costs. Costs based on construct were compared using multivariable adjusted analyses using negative binomial regression. The primary outcome measures were cost differences between ACDF techniques. RESULTS: Two hundred sixty-four patients were included, with procedures by 13 surgeons across 4 institutions. The total procedural cost for ACDF had a mean of US$2317 with wide variation (range, US$967-US$7370). Multivariable analysis revealed body mass index and use of polyether ether ketone to be correlated with increased cost while carbon fiber and autograft correlated with decreased cost. When comparing standalone device constructs to cases with anterior instrumentation (plate/screws), the total cost was significantly higher in the plate/screw group (US$2686±US$921 vs. US$1466±US$878, P <0.001). CONCLUSIONS: We encountered wide variation in procedural costs associated with ACDF, including as much as an 8-fold difference in the cost of constructs. The most important drivers included instrumentation type and implant materials. Here, we identify potential targets of opportunity for health care organizations that are looking to reduce variance in procedural expenditures to improve health care savings associated with the performance of ACDF.


Assuntos
Fusão Vertebral , Humanos , Estudos Retrospectivos , Fusão Vertebral/métodos , Resultado do Tratamento , Discotomia/métodos , Placas Ósseas , Vértebras Cervicais/cirurgia
16.
Orthop Traumatol Surg Res ; 109(5): 103532, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36572380

RESUMO

INTRODUCTION: Humeral shaft non-union is frequent, with severe clinical impact. Management, however, is poorly codified and there is no clear decision-tree. HYPOTHESIS: Analyzing our experience over the last 15years could enable a reproducible strategy to be drawn up, with a decision-tree based on the 2 main causes: failure of internal fixation, and infection. MATERIAL AND METHOD: Sixty-one patients were included in a retrospective cohort, with a mean 94 months' follow-p. The treatment strategy was based on screening first for infection then for mechanical stability deficit in case of prior internal fixation. Any fixation revision was associated to cancellous autograft. In case of suspected or proven infection, 2-stage treatment was implemented. In case of primary non-operative treatment, the strategy was based on the non-union risk on the Non-Union Scoring System (NUSS), with internal fixation and possible graft. RESULTS: There were 6 failures, for a consolidation rate of 90%; excluding patients not managed according to the study protocol, the consolidation rate was 95%. There was 1 case of spontaneously resolving postoperative radial palsy, and 3 patients required surgical revision. DISCUSSION: The present strategy achieved consolidation in most cases, providing the surgeon with a decision-tree for these patients. Infectious etiologies are often overlooked and should be a focus of screening. LEVEL OF EVIDENCE: IV, retrospective or historical series.


Assuntos
Fraturas não Consolidadas , Fraturas do Úmero , Humanos , Resultado do Tratamento , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Estudos Retrospectivos , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Consolidação da Fratura , Placas Ósseas , Radiografia , Úmero/cirurgia , Fixação Interna de Fraturas/métodos
17.
Bone Joint J ; 104-B(11): 1225-1233, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36317342

RESUMO

AIMS: The aim of this study was to compare the cost-effectiveness of surgical fixation with Kirschner (K-)wire ersus moulded casting after manipulation of a fracture of the distal radius in an operating theatre setting. METHODS: An economic evaluation was conducted based on data collected from the Distal Radius Acute Fracture Fixation Trial 2 (DRAFFT2) multicentre randomized controlled trial in the UK. Resource use was collected at three, six, and 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from an NHS and personal social services perspective. Sensitivity analyses were conducted to examine the robustness of cost-effectiveness estimates, and decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves. RESULTS: In the base case analysis, surgical fixation with K-wire was more expensive (£29.65 (95% confidence interval (CI) -94.85 to 154.15)) and generated lower QALYs (0.007 (95% CI -0.03 to 0.016)) than moulded casting, but this difference was not statistically significant. The probability of K-wire being cost-effective at a £20,000 per QALY cost-effectiveness threshold was 24%. The cost-effectiveness results remained robust in the sensitivity analyses. CONCLUSION: The findings suggest that surgical fixation with K-wire is unlikely to be a cost-effective alternative to a moulded cast in adults, following manipulation of a fracture of the distal radius in a theatre setting.Cite this article: Bone Joint J 2022;104-B(11):1225-1233.


Assuntos
Fraturas Ósseas , Fraturas do Rádio , Adulto , Humanos , Fios Ortopédicos , Análise Custo-Benefício , Rádio (Anatomia) , Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas do Rádio/cirurgia , Fixação de Fratura/métodos
18.
ANZ J Surg ; 92(12): 3311-3318, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36333993

RESUMO

BACKGROUND: Given the cost differential between surgical and non-surgical management of distal radius fractures, we aimed to evaluate the cost-effectiveness of surgical compared with non-surgical treatment of distal radius fractures in a cohort of older patients. METHODS: This evaluation was conducted alongside the combined randomized and observational study of surgery for fractures of the distal radius in the elderly (CROSSFIRE) trial (ACTRN 12616000969460) which compared surgical (open reduction and internal fixation using volar-locking plate (VLP) fixation) and non-surgical (closed fracture reduction and cast immobilization (CR)) treatment for displaced distal radius fractures in patients ≥60 years. Cost-effectiveness was assessed from the perspective of the public hospital funder. Hospital records from a sub-sample of participants were used to estimate costs. Outcomes were patient-reported wrist pain and function questionnaire (PRWE) scores and quality adjusted life years (QALYs) calculated using the EuroQoL five-dimension five-level tool (EQ-5D-5L). RESULTS: From 166 participants (81 surgical, 85 non-surgical), costs were obtained for 56 (29 surgical, 27 non-surgical). The mean costs for VLP fixation were Australian dollars (AUD) 6668 (95% CI $4857 to $8479) compared to AUD 3343 (95% CI $1304 to $5381) for CR. The incremental cost-effectiveness ratios (ICER) to achieve a 1-point improvement in the PRWE were AUD 375, AUD 1736 and AUD 1126 at 3, 12 and 24 months for VLP compared with CR. At 12 months, the cost effectiveness was dominated by CR (lower cost and better QoL) whereas at 24 months, the incremental cost per QALY gained by VLP was AUD 1 946 127. CONCLUSION: In the treatment of distal radius fractures in patients ≥60 years, VLP fixation was not cost-effective compared with CR from the perspective of hospital funders.


Assuntos
Fixação Interna de Fraturas , Fraturas do Rádio , Idoso , Humanos , Pessoa de Meia-Idade , Austrália , Placas Ósseas , Análise de Custo-Efetividade , Fixação Interna de Fraturas/economia , Fixação Interna de Fraturas/métodos , Estudos Observacionais como Assunto , Fraturas do Rádio/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento , Custos Hospitalares
19.
J Hand Surg Asian Pac Vol ; 27(5): 845-851, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36178413

RESUMO

Background: The objective of this study was to determine whether economic well-being is associated with patient-reported functional outcomes and range of motion 1 year following volar plate fixation of distal radius fracture. Methods: A retrospective study was performed on 200 patients with distal radius fractures treated with volar plate fixation at two Level 1 trauma centres from 2006 to 2017 with 1-year clinical follow-up using a previously published cohort. The economic well-being of patients was assessed using the Distressed Communities Index (DCI). Our outcome variables were patient-reported functional outcomes assessed by QuickDASH score and wrist and forearm range of motion 1 year after surgery. The analysis of variance (ANOVA) test was used to compare outcome variables across pre-established tiers of economic well-being. Results: The mean QuickDASH score at 1 year following distal radius fracture volar plate fixation was 10.8 and ranged from 7.3 to 12.2 across tiers of economic well-being. QuickDASH score and wrist range of motion were not significantly different across all tiers of economic well-being. However, wrist flexion-extension arc at 1 year following surgery was significantly decreased in the economically at-risk group compared with the remaining cohort. Conclusions: Patient-reported functional outcomes 1 year after volar plate fixation of distal radius fracture are similar across tiers of economic well-being. Economically disadvantaged patients are at risk for poorer wrist motion following distal radius fracture surgery, though it is not clear if this difference is clinically significant. Level of Evidence: Level II (Prognostic).


Assuntos
Fraturas do Rádio , Humanos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/etiologia , Fixação Interna de Fraturas/efeitos adversos , Estudos Retrospectivos , Placas Ósseas/efeitos adversos , Articulação do Punho
20.
Acta Orthop ; 93: 750-755, 2022 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-36148615

RESUMO

BACKGROUND AND PURPOSE: Proximal humeral fractures (PHF) can be managed surgically or non-surgically. Locking plates have been the preferred head-preserving surgical technique while hemiarthroplasty (HA) or reverse shoulder arthroplasty (RSA) have been used in joint replacement surgery. We describe the epidemiology and trends in management of acute PHF in Denmark with a focus on (i) changes in the incidence of PHF; (ii) changes in the proportion of surgical cases; and (iii) changes in preferred surgical techniques. PATIENTS AND METHODS: Data on diagnoses and interventions was retrieved from the Danish National Patient Register. Patients aged 18 years and above were included. Surgical treatment was defined as the diagnosis of PHF combined with a predefined surgical procedure code within 3 weeks of injury. Data on plate osteosynthesis, HA, RSA, and "other techniques" was retrieved. Non-surgical treatment was defined as no relevant surgical procedure code within 3 weeks. RESULTS: We identified 137,436 PHF (72% women) in the Danish National Patient Register. The overall mean incidence was 138/100,000/year (500 for women 60 years or above). Non-surgical treatment accounted for 119,966 (87%). The 17,470 surgical procedures included 42% locking plates, 34% arthroplasties, and 25% other techniques. The rate of surgery declined from 17% in 2013 to 11% in 2018. INTERPRETATION: The overall incidence of PHF remained stable between 1996 and 2018 but the absolute number increased. The approach to PHF remains predominantly non-surgical. The number of surgeries in Denmark have decreased since 2013, especially for locking plates and HA, while RSA is increasingly used.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Fraturas do Ombro , Adulto , Artroplastia do Ombro/métodos , Placas Ósseas , Dinamarca/epidemiologia , Feminino , Fixação Interna de Fraturas , Humanos , Masculino , Fraturas do Ombro/epidemiologia , Fraturas do Ombro/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA