Radiat Environ Biophys ; 54(2): 225-41, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25724676

RESUMO

Laboratory rats are frequently used in inhalation studies as a surrogate for human exposures. The objective of the present study was therefore to develop a stochastic dosimetry model for inhaled radon progeny in the rat lung, to predict bronchial dose distributions and to compare them with corresponding dose distributions in the human lung. The most significant difference between human and rat lungs is the branching structure of the bronchial tree, which is relatively symmetric in the human lung, but monopodial in the rat lung. Radon progeny aerosol characteristics used in the present study encompass conditions typical for PNNL and COGEMA rat inhalation studies, as well as uranium miners and human indoor exposure conditions. It is shown here that depending on exposure conditions and modeling assumptions, average bronchial doses in the rat lung ranged from 5.4 to 7.3 mGy WLM(-1). If plotted as a function of airway generation, bronchial dose distributions exhibit a significant maximum in large bronchial airways. If, however, plotted as a function of airway diameter, then bronchial doses are much more uniformly distributed throughout the bronchial tree. Comparisons between human and rat exposures indicate that rat bronchial doses are slightly higher than human bronchial doses by about a factor of 1.3, while lung doses, averaged over the bronchial (BB), bronchiolar (bb) and alveolar-interstitial (AI) regions, are higher by about a factor of about 1.6. This supports the current view that the rat lung is indeed an appropriate surrogate for the human lung in case of radon-induced lung cancers. Furthermore, airway diameter seems to be a more appropriate morphometric parameter than airway generations to relate bronchial doses to bronchial carcinomas.


Assuntos
Inalação , Neoplasias Pulmonares , Pulmão/metabolismo , Pulmão/efeitos da radiação , Modelos Biológicos , Produtos de Decaimento de Radônio/metabolismo , Produtos de Decaimento de Radônio/toxicidade , Animais , Brônquios/metabolismo , Brônquios/efeitos da radiação , Humanos , Masculino , Doses de Radiação , Radiometria , Ratos , Medição de Risco , Especificidade da Espécie , Processos Estocásticos
2.
Health Phys ; 99(4): 523-31, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20838094

RESUMO

The main sources of intersubject variations considered in the present study were: (1) size and structure of nasal and oral passages, affecting extrathoracic deposition and, in further consequence, the fraction of the inhaled activity reaching the bronchial region; (2) size and asymmetric branching of the human bronchial airway system, leading to variations of diameters, lengths, branching angles, etc.; (3) respiratory parameters, such as tidal volume, and breathing frequency; (4) mucociliary clearance rates; and (5) thickness of the bronchial epithelium and depth of target cells, related to airway diameters. For the calculation of deposition fractions, retained surface activities, and bronchial doses, parameter values were randomly selected from their corresponding probability density functions, derived from experimental data, by applying Monte Carlo methods. Bronchial doses, expressed in mGy WLM-1, were computed for specific mining conditions, i.e., for defined size distributions, unattached fractions, and physical activities. Resulting bronchial dose distributions could be approximated by lognormal distributions. Geometric standard deviations illustrating intersubject variations ranged from about 2 in the trachea to about 7 in peripheral bronchiolar airways. The major sources of the intersubject variability of bronchial doses for inhaled radon progeny are the asymmetry and variability of the linear airway dimensions, the filtering efficiency of the nasal passages, and the thickness of the bronchial epithelium, while fluctuations of the respiratory parameters and mucociliary clearance rates seem to compensate each other.


Assuntos
Brônquios/metabolismo , Exposição por Inalação/análise , Modelos Biológicos , Doses de Radiação , Produtos de Decaimento de Radônio/metabolismo , Algoritmos , Humanos , Método de Monte Carlo , Radiometria , Produtos de Decaimento de Radônio/análise , Produtos de Decaimento de Radônio/farmacocinética , Processos Estocásticos