Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Am J Vet Res ; 68(12): 1348-53, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18052740

RESUMO

OBJECTIVE: To determine agreement for total protein (TP) and albumin concentrations measured by a point-of-care biochemical analyzer in heparinized whole blood and plasma samples obtained from psittacines and compare results with those from a commercial laboratory. SAMPLE POPULATION: Hematologic samples from 92 healthy birds. PROCEDURES: Duplicate samples of heparinized whole blood and plasma were obtained. A point-of-care biochemical analyzer was used to determine TP and albumin concentrations. To assess precision, intraclass correlation coefficient (r(i)) and Bland-Altman measures of agreement were used. These results were compared by use of Bland-Altman plots with those obtained from a commercial laboratory that used a biuret method for TP concentration and electrophoresis for albumin concentration. RESULTS: For the analyzer, there was excellent agreement (r(i) = 0.91) between heparinized whole blood and plasma samples for TP and albumin concentrations. Relative error was 0.9% for TP and 0.7% for albumin. Analyzer results correlated well with commercial laboratory results, with a downward bias of 0.6 for TP and 0.3 for albumin. CONCLUSIONS AND CLINICAL RELEVANCE: The analyzer had excellent precision for analysis of heparinized whole blood or plasma samples for TP or albumin concentrations; analyzer values had good agreement with those from a commercial laboratory. The analyzer could be a valid method to measure plasma TP concentrations and provide point-of-care testing in apparently healthy parrots. Biochemical analyzer results for plasma albumin concentration were not validated by results from a commercial laboratory, so conclusions cannot be drawn regarding use of the analyzer in measurement of albumin concentrations in psittacines.


Assuntos
Albuminas/metabolismo , Análise Química do Sangue/veterinária , Proteínas Sanguíneas/análise , Laboratórios/normas , Sistemas Automatizados de Assistência Junto ao Leito , Psittaciformes/sangue , Animais , Análise Química do Sangue/instrumentação , Psittaciformes/metabolismo
2.
Am J Vet Res ; 66(3): 375-8, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15822578

RESUMO

OBJECTIVE: To determine the reliability of plasma electrophoresis (EPH) in psittacine birds. ANIMALS: 93 psittacine birds. PROCEDURE: Jugular venipuncture was performed on 93 awake psittacine birds. The plasma was centrifuged, separated, aliquoted into duplicate samples, frozen, and sent to 2 commercial laboratories that routinely perform avian EPH. Samples from 51 birds were sent to laboratory A, and samples from 42 birds were sent to laboratory B. The reliability of EPH results within each laboratory was assessed, but not between laboratories. To determine the reliability (agreement between duplicate samples) of total protein, albumin, prealbumin, alpha1-, alpha2-, beta-, and gamma-globulin concentrations, the intraclass correlation coefficient (r(i)) was calculated. RESULTS: Both laboratories had excellent agreement between samples for measurement of total protein concentration and only good agreement for albumin concentration. Except for the prealbumin concentration measured at laboratory B, both laboratories had poor agreement for all other values of the EPH. CONCLUSIONS AND CLINICAL RELEVANCE: These data indicate that plasma EPH for measuring prealbumin, alpha1-, alpha2-, beta-, and gamma-globulin concentrations may not be a reliable tool for assessing avian health. Small amounts of these proteins in birds plus human variation in reading the EPH curves may lead to variable results. Avian veterinarians should cautiously interpret results from plasma EPH assays for these protein fractions.


Assuntos
Proteínas Sanguíneas/análise , Psittaciformes/sangue , Animais , Eletroforese das Proteínas Sanguíneas/métodos , Eletroforese das Proteínas Sanguíneas/veterinária , Estudos de Avaliação como Assunto , Globulinas/metabolismo , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA