RESUMO
AIM: While delivering radiotherapy it is utmost important to minimize target motion to decrease margins in postoperative gynaecological patients. Hence certain bladder and rectum filling protocols are followed by each institute. During cone beam computed tomography (CBCT) verification, we observed that this motion was more affected by rectal filling. To verify, we retrospectively analysed the vaginal movement and its relation with bladder and rectum filling. MATERIALS AND METHODS: We evaluated CBCTs of 15 patients of carcinoma endometrium. Bladder and rectum both were contoured offline on each scan. To assess the motion of vagina, two reference points were selected. Posterior movement of bladder and anterior movement of rectum were noted on these points on each scan. RESULTS: Total 150 scans (135 KV-CBCT scans and 15 planning computed tomography) of 15 patients were studied. Stepwise regression analysis reported that bladder wall changes has a nonsignificant relationship with bladder volume among all the individuals. The significant rectal wall changes both at Point X and Y were observed in six patients and only at Point X in three patients. Rest of the patients showed no significant relationship in their CBCT scans. Thus 60% patients showed significant relation between rectal volume and rectal wall changes. CONCLUSION: Hence we suggest to advice our patients more regarding volume of rectum to decrease vaginal motion. Bladder volume is needed to decrease the dose to small intestine. However prospective data with large number of patients in the study is required to confirm these findings.
Assuntos
Neoplasias do Endométrio/radioterapia , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Reto/fisiologia , Bexiga Urinária/fisiologia , Vagina/fisiologia , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias do Endométrio/patologia , Feminino , Humanos , Período Pós-Operatório , Estudos RetrospectivosRESUMO
Fecal continence is maintained by several mechanisms including anatomical factors, anorectal sensation, rectal compliance, stool consistency, anal muscle strength, mobility, and psychological factors. The homeostatic balance is easily disturbed, resulting in symptoms including fecal incontinence and constipation. Current technologies for assessment of anorectal function have limitations. Overlap exist between data obtained in different patient groups, and there is lack of correlation between measurements and symptoms. This review describes a novel technology named Fecobionics for assessment of anorectal physiology. Fecobionics is a simulated stool, capable of dynamic measurements of a variety of variables during defecation in a single examination. The data facilitate novel analysis of defecatory function as well as providing the foundation for modeling studies of anorectal behavior. The advanced analysis can enhance our physiological understanding of defecation and future interdisciplinary research for unraveling defecatory function, anorectal sensory-motor disorders, and symptoms. This is a step in the direction of improved diagnosis of anorectal diseases.
Assuntos
Canal Anal/fisiologia , Fezes , Reto/fisiologia , Canal Anal/anatomia & histologia , Fenômenos Biomecânicos , Defecação/fisiologia , Humanos , Manometria , Modelos Biológicos , Pressão , Reto/anatomia & histologia , Sensação/fisiologiaRESUMO
OBJECTIVE: To assess differences in regional brain temperatures during whole-body hypothermia and test the hypothesis that brain temperature profile is nonhomogenous in infants with hypoxic-ischemic encephalopathy. STUDY DESIGN: Infants with hypoxic-ischemic encephalopathy were enrolled prospectively in this observational study. Magnetic resonance (MR) spectra of basal ganglia, thalamus, cortical gray matter, and white matter (WM) were acquired during therapeutic hypothermia. Regional brain tissue temperatures were calculated from the chemical shift difference between water signal and metabolites in the MR spectra after performing calibration measurements. Overall difference in regional temperature was analyzed by mixed-effects model; temperature among different patterns and severity of injury on MR imaging also was analyzed. Correlation between temperature and depth of brain structure was analyzed using repeated-measures correlation. RESULTS: In total, 53 infants were enrolled (31 girls, mean gestational age: 38.6 ± 2 weeks; mean birth weight: 3243 ± 613 g). MR spectroscopy was acquired at mean age of 2.2 ± 0.6 days. A total of 201 MR spectra were included in the analysis. The thalamus, the deepest structure (36.4 ± 2.3 mm from skull surface), was lowest in temperature (33.2 ± 0.8°C, compared with basal ganglia: 33.5 ± 0.9°C; gray matter: 33.6 ± 0.7°C; WM: 33.8 ± 0.9°C, all P < .001). Temperatures in more superficial gray matter and WM regions (depth: 21.9 ± 2.4 and 21.5 ± 2.2 mm) were greater than the rectal temperatures (33.4 ± 0.4°C, P < .03). There was a negative correlation between temperature and depth of brain structure (rrm = -0.36, P < .001). CONCLUSIONS: Whole-body hypothermia was effective in cooling deep brain structures, whereas superficial structures were warmer, with temperatures significantly greater than rectal temperatures.
Assuntos
Temperatura Corporal/fisiologia , Encéfalo/diagnóstico por imagem , Hipotermia Induzida , Hipóxia-Isquemia Encefálica/terapia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Encéfalo/fisiologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Reto/fisiologia , TermometriaRESUMO
INTRODUCTION: Health care providers are increasingly challenged to balance cost considerations for devices, drugs, and staffing all while continuing to provide excellent care. Patients in both the post-acute and acute care settings often require fluid and/or medication when their oral route is compromised and vascular access may not be warranted or immediately accessible. The rectum is an underutilized administration point that can be accessed with speed and relative ease. Areas Covered: Literature reviews of pharmaceutical, medical, and nursing references reveal current and historical science that validates the rectal route as a means of alternative administration for fluids and medications. Expert Commentary: Historically the rectum has been used for medication and fluid delivery but in more recent times, use has waned due to many factors. The physiology of the rectum allows for rapid and reliable administration of a variety of medications as well as hydration. This serves as an introduction to a novel, simple, cost effective device that allows for discreet and painless rectal administration of fluids and medications when the oral route is compromised and/or intravenous access is difficult or unnecessary. This device is used in a variety of patients in many care settings.
Assuntos
Catéteres , Hidratação , Reto/fisiologia , Administração Retal , Catéteres/economia , Custos e Análise de Custo , Hidratação/economia , Humanos , Vigilância de Produtos Comercializados/economiaRESUMO
BACKGROUND: Endoanal MRI and MR defecography are used to identify anal sphincter injury and disordered defecation. However, few studies have evaluated findings in asymptomatic healthy people. The effects of BMI and parity on rectoanal motion and evacuation are unknown. METHODS: In 113 asymptomatic females (age 50 ± 17 years, Mean ± SD) without risk factors for anorectal trauma, anal sphincter appearance, anorectal motion, and pelvic organ prolapse were evaluated with MRI. The relationship between age, BMI, and parity and structural findings were evaluated with parametric and non-parametric tests. RESULTS: The anal sphincters and puborectalis appeared normal in over 90% of women. During dynamic MRI, the anorectal angle was 100 ± 1º (Mean ± SEM) at rest, 70 ± 2° at squeeze, and 120 ± 2° during defecation. The change in anorectal angle during squeeze (r = -.25, P < .005), but not during evacuation (r = .13, P = .25) was associated with age. In the multivariable models, BMI (P < .01) and parity (P < .01) were, respectively, independently associated with the intersubject variation in the anorectal angle at rest and the angle change during squeeze. Ten percent or fewer women had had descent of the bladder base or uterus 4 cm or more below the pubococcygeal line or a rectocele measuring 4 cm or larger. Only 5% had a patulous anal canal. CONCLUSIONS: In addition to age, BMI and parity also affect anorectal motion in asymptomatic women. These findings provide age-adjusted normal values for rectoanal anatomy and pelvic floor motion.
Assuntos
Canal Anal/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Prolapso de Órgão Pélvico/diagnóstico por imagem , Reto/diagnóstico por imagem , Adulto , Fatores Etários , Idoso , Canal Anal/fisiologia , Índice de Massa Corporal , Estudos de Coortes , Defecografia/métodos , Feminino , Voluntários Saudáveis , Humanos , Pessoa de Meia-Idade , Prolapso de Órgão Pélvico/fisiopatologia , Reto/fisiologiaRESUMO
BACKGROUND: Normal defaecation involves activation of anorectal mechanoreceptors responsive to pressure and stretch. The aim of this study was to develop selective anal and rectal mucosal light-touch stimulation suitable for measurement of cortical evoked potentials (EPs) in order to explore the sensory arm of these pathways. NEW METHOD: A novel device was manufactured to deliver selective rectal and/or anal light-touch stimulation using a shielded inter-dental brush mounted on a rotating stepper motor (1Hz, 1ms, 15° rotation). Resultant somatosensory EPs recorded with a 32-channel cortical multi-electrode array were compared to those elicited by electrical anorectal stimulation (2mm anal plug electrode [1Hz, 1ms, 10V]). RESULTS: Eighteen anaesthetized female Wistar rats (body mass 180-250g) were studied. Electrical and mechanical stimulation provoked similar maximal response amplitudes (electrical anorectal 39.0µV[SEM 5.5], mechanical anal 42.2µV[8.1], mechanical rectal 45.8µV[9.0]). Response latency was longer following mechanical stimulation (electrical anorectal 8.8ms[0.5], mechanical anal 16.4ms[1.1], mechanical rectal 18.3ms[2.5]). The extent of activated sensory cortex was smaller for mechanical stimulation. Sensory inferior rectal nerve activity was greater during anal compared to rectal mechanical in a subgroup of 4 rats. Evoked potentials were reproducible over 40min in a subgroup of 9 rats. COMPARISON WITH EXISTING METHODS: Cortical EPs are typically recorded in response to non-physiological electrical stimuli. The use of a mechanical stimulus may provide a more localized physiological method of assessment. CONCLUSIONS: To the authors' knowledge these are the first selective brush-elicited anal and rectal EPs recorded in animals and provide a physiological approach to testing of anorectal afferent pathways.
Assuntos
Canal Anal/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Estimulação Física/métodos , Reto/fisiologia , Córtex Somatossensorial/fisiologia , Percepção do Tato/fisiologia , Animais , Equipamentos e Provisões Elétricas , Desenho de Equipamento , Feminino , Mucosa Intestinal/fisiologia , Estimulação Física/instrumentação , Impressão Tridimensional , Ratos Wistar , Reto/inervação , Tato/fisiologiaRESUMO
Biogalvanic characterisation is a promising method for obtaining health-specific tissue information. However, there is a dearth of understanding in the literature regarding the underlying galvanic cell, electrode reactions and their controlling factors which limits the application of the technique. This work presents a parametric electrochemical investigation into a zinccopper galvanic system using salt (NaCl) solution analogues at physiologically-relevant concentrations (1.71, 17.1 & 154 mM). The potential difference at open cell, closed cell maximum current and the internal resistance (based on published characterisation methods) were measured. Additionally, independent and relative polarisation scans of the electrodes were performed to improve understanding of the system. Our findings suggest that the prominent reaction at the cathode is that of oxygen-reduction, not hydrogen-evolution. Results indicate that cell potentials are influenced by the concentration of dissolved oxygen at low currents and maximum closed cell currents are limited by the rate of oxygen diffusion to the cathode. Characterised internal resistance values for the salt solutions did not correspond to theoretical values at the extremes of concentration (1.71 and 154 mM) due to electrode resistance and current limitation. Existing biogalvanic models do not consider these phenomena and should be improved to advance the technique and its practical application.
Assuntos
Eletroquímica/métodos , Eletrofisiologia/instrumentação , Cobre/química , Corrosão , Eletrodos , Eletrofisiologia/métodos , Desenho de Equipamento , Humanos , Modelos Químicos , Oxigênio/química , Reto/química , Reto/fisiologia , Cloreto de Sódio/química , Zinco/químicaRESUMO
OBJECTIVE: Pathogenesis of anal fissure (AF) is associated with raised resting anal pressures (RAP) involving contraction of smooth muscle. Therefore, the drug delivery strategy should be customized to reduce this raised RAP. In this investigation, in order to achieve this task, a transdermal nanoemulsion (NE) gel of lercanidipine (LER) was developed and optimized to evaluate its permeation ability and in vivo performance. Further, the same formulation was explored for droplet size analysis, zeta potential measurement and stability studies. METHODS: Pseudo-ternary phase diagram was constructed to determine NE region. The NE was optimized (OPT) by employing three-factor, three-level Box-Behnken design expert software; the independent variables decided were composition of oil, Smix and water and dependent variables, that is, responses were cumulative amount of drug permeated across rat abdominal skin in 24 h (Q24), steady-state flux (Js) and viscosity. The in vivo efficacy was assessed by measuring anorectal pressure in male Wistar rats. RESULTS: The OPT NE formulation, composed of Capryol 90 (12.70% w/w), Cremophor EL (18.0% w/w), Transcutol HP (18.0% w/w) and water (60.00%) w/w was found to have permeation flux of 60.27 µg/cm(2)/h, release of 1699.52 µg/24 h and 491.95 cP viscosity. In addition, a small average droplet size (82.71 ± 9.96 nm) and long-term stability at room temperature (1.666 years) was observed. The in vivo investigation demonstrated direct evidence on significant reduction (27.75%) in anorectal pressure over a period of 4 h. CONCLUSION: These preliminary finding suggested that NE-based gel system of LER may provide promising perspective in management of AF.
Assuntos
Canal Anal/fisiologia , Bloqueadores dos Canais de Cálcio/administração & dosagem , Di-Hidropiridinas/administração & dosagem , Sistemas de Liberação de Medicamentos , Fissura Anal/tratamento farmacológico , Músculo Liso/efeitos dos fármacos , Reto/fisiologia , Administração Cutânea , Animais , Bloqueadores dos Canais de Cálcio/farmacocinética , Química Farmacêutica , Di-Hidropiridinas/farmacocinética , Géis/química , Masculino , Microscopia Eletrônica de Transmissão , Músculo Liso/fisiologia , Tamanho da Partícula , Ratos , Ratos Wistar , Refratometria , Pele/efeitos dos fármacos , Absorção Cutânea , ViscosidadeRESUMO
PURPOSE: Pelvic radiotherapy (PRT) is known to adversely affect bowel function (BF) and patient well-being. This study characterized long-term BF and evaluated quality of life (QOL) in patients receiving PRT. METHODS: Data from 252 patients were compiled from two North Central Cancer Treatment Group prospective studies, which included assessment of BF and QOL by the BF questionnaire (BFQ) and Uniscale QOL at baseline and 12 and 24 months after completion of radiotherapy. BFQ scores (sum of symptoms), Uniscale results, adverse-event incidence, and baseline demographic data were compared via t test, χ (2), Fisher exact, Wilcoxon, and correlation methodologies. RESULTS: The total BFQ score was higher than baseline at 12 and 24 months (P < 0.001). More patients had five or more symptoms at 12 months (13 %) and 24 months (10 %) than at baseline (2 %). Symptoms occurring in greater than 20 % of patients at 12 and 24 months were clustering, stool-gas confusion, and urgency. Factors associated with worse BF were female sex, rectal or gynecologic primary tumors, prior anterior resection of the rectum, and 5-fluorouracil chemotherapy. Patients experiencing grade 2 or higher acute toxicity had worse 24-month BF (P values, <.001-.02). Uniscale QOL was not significantly different from baseline at 12 or 24 months, despite worse BFQ scores. CONCLUSIONS: PRT was associated with worse long-term BF. Worse BFQ score was not associated with poorer QOL. Further research to characterize the subset of patients at risk of significant decline in BF is warranted.
Assuntos
Neoplasias Gastrointestinais/radioterapia , Lesões por Radiação/etiologia , Reto/fisiologia , Reto/efeitos da radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Ensaios Clínicos Fase III como Assunto , Diarreia/etiologia , Feminino , Glutamina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Pelve/efeitos da radiação , Estudos Prospectivos , Qualidade de Vida , Lesões por Radiação/fisiopatologia , Radioterapia/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Inquéritos e QuestionáriosRESUMO
The aim was to determine the feasibility of vascular quantification of the bowel wall for different anatomical segments of the colorectum. Following institutional ethical approval and informed consent, 39 patients with colorectal cancer underwent perfusion CT. Blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product (PS) were assessed for different segments of the colorectum: ascending, transverse, descending colon, sigmoid, or rectum, that were distant from the tumor, and which were proven normal on contemporary colonoscopy, and subsequent imaging and clinical follow up. Mean (SD) for BF, BV, MTT and PS for the different anatomical colorectal segments were obtained and compared using a pooled t-test. Significance was at 5%. Assessment was not possible in 9 of 39 (23%) patients as the bowel wall was ≤ 5 mm precluding quantitative analysis. Forty-four segments were evaluated in the remaining 30 patients. Mean BF was higher in the proximal than distal colon: 24.0 versus 17.8 mL/min/100g tissue; p=0.009; BV, MTT and PS were not significantly different; BV: 3.46 versus 3.15 mL/100g tissue, p=0.45; MTT: 15.1 versus 18.3s; p=0.10; PS: 6.84 versus 8.97 mL/min/100 tissue, p=0.13, respectively. In conclusion, assessment of bowel wall perfusion may fail in 23% of patients. The colorectum demonstrates segmental differences in perfusion.
Assuntos
Colo/diagnóstico por imagem , Colo/fisiologia , Imagem de Perfusão/métodos , Reto/diagnóstico por imagem , Reto/fisiologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Velocidade do Fluxo Sanguíneo , Colo/irrigação sanguínea , Estudos de Viabilidade , Feminino , Humanos , Masculino , Reto/irrigação sanguíneaRESUMO
Body temperature was measured at five different body sites (retroperitoneum, groin, semimembranosus muscle, flank and shoulder) using temperature-sensitive microchips implanted in five female goats, and compared with the core body and rectal temperatures. Body temperature was measured while the goats were kept in different ambient temperatures, with and without radiant heat, as well as during a fever induced experimentally by injection of bacterial lipopolysaccharide. Bland-Altman limit of agreement analysis was used to compare the temperature measurements at the different body sites during the different interventions. Temperatures measured by the microchip implanted in the retroperitoneum showed the closest agreement (mean 0.2 °C lower) with core and rectal temperatures during all interventions, whereas temperatures measured by the microchips implanted in the groin, muscle, flank and shoulder differed from core body temperature by up to 3.5 °C during the various interventions.
Assuntos
Temperatura Corporal/fisiologia , Cabras/fisiologia , Procedimentos Analíticos em Microchip/veterinária , Animais , Feminino , Reto/fisiologia , Reprodutibilidade dos Testes , Espaço Retroperitoneal/fisiologia , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: Brain-gut dysfunction has been implicated in gastrointestinal disorders but a comprehensive test of brain-gut axis is lacking. We developed and tested a novel method for assessing both afferent anorectal-brain function using cortical evoked potentials (CEP), and efferent brain-anorectal function using motor evoked potentials (MEP). METHODS: Cortical evoked potentials was assessed following electrical stimulations of anus and rectum with bipolar electrodes in 26 healthy subjects. Anorectal MEPs were recorded following transcranial magnetic stimulation (TMS) over paramedian motor cortices bilaterally. Anal and rectal latencies/amplitudes for CEP and MEP responses and thresholds for first sensation and pain (mA) were analyzed and compared. Reproducibility and interobserver agreement of responses were examined. KEY RESULTS: Reproducible polyphasic rectal and anal CEPs were recorded in all subjects, without gender differences, and with negative correlation between BMI and CEP amplitude (r -0.66, P=0.001). Transcranial magnetic stimulation evoked triphasic rectal and anal MEPs, without gender differences. Reproducibility for CEP and MEP was excellent (CV <10%). The inter-rater CV for anal and rectal MEPs was excellent (ICC 97-99), although there was inter-subject variation. CONCLUSIONS & INFERENCES: Combined CEP and MEP studies offer a simple, inexpensive and valid method of examining bidirectional brain-anorectal axes. This comprehensive method could provide mechanistic insights into lower gut disorders.
Assuntos
Canal Anal/fisiologia , Córtex Cerebral/fisiologia , Potenciais Evocados/fisiologia , Reto/fisiologia , Adulto , Canal Anal/inervação , Córtex Cerebral/anatomia & histologia , Estimulação Elétrica , Feminino , Gastroenteropatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reto/inervação , Reprodutibilidade dos Testes , Limiar Sensorial , Estimulação Magnética Transcraniana , Adulto JovemRESUMO
PURPOSE: Assessment of rectal distention in a group of patients who are not receiving daily rectum emptying procedures during a course of prostate cancer radiotherapy to investigate which patients could benefit from daily rectum emptying. METHODS AND MATERIALS: Eighteen patients underwent daily megavoltage CT (MVCT) scanning with positioning based on bony anatomy. Emptying the rectum was only performed before planning CT and not during the actual treatment. The rectal average cross-sectional area (CSA) was determined on the MVCTs. The relative CSA (CSA(rel)) was defined as CSA on MVCT / CSA on planning CT. Additional prostate soft tissue matching was performed to verify the influence of rectal distention on prostate motion. RESULTS: Two distinct subgroups could be defined a posteriori. One group had a limited and stable rectal distention with a CSA (mean+/-SD) of 6.6+/-2.1cm(2), in contrast with a second group with large and variable rectal filling with a CSA of 9.5+/-3.7cm(2) (p<0.01). Mean anterior-posterior prostate displacement was 0.4+/-2.4 mm in the stable group versus -2.4+/-6.1 mm in the unstable group (p<0.01). A mean CSA(rel) of 1.35 of the first 3 days as cut-off value allowed for a correct a priori classification of 90% and 85% of the patients from groups 1 and 2, respectively. CONCLUSION: Based on a few measurements of the CSA by daily MVCT imaging at the first days of treatment, rectum emptying may be omitted in part of the patients.
Assuntos
Neoplasias da Próstata/radioterapia , Reto/fisiologia , Tomografia Computadorizada por Raios X/métodos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Reto/anatomia & histologiaRESUMO
Stress plays an important role in the development of visceral hypersensitivity, a key mechanism underlying the pathophysiology of the irritable bowel syndrome. Visceral sensitivity in rats is generally assessed under restrain conditions. To avoid this potential stress factor, we developed a model using implanted radio telemetry for remote measurement of the visceromotor response (VMR) to colorectal distention (CRD). Ten days after implantation of a radio telemetry transmitter and EMG electrodes, visceral sensitivity was evaluated by applying a standardized distension protocol (1, 1.5 and 2 mL) on three different days. In a second series, visceral sensitivity was assessed in maternally separated rats before, directly after and at 6 and 24 h after water avoidance (WA) stress. CRD resulted in a reproducible VMR response on the three different study days. In separated but not in non-handled rats, WA significantly increased visceral sensitivity at 6 h (P=0.006) and 24 h (P=0.004) after WA. Our results show that radio telemetry is a reliable and well tolerated new tool for evaluating visceral sensitivity in rats. These data further confirm that maternal separation is a good model for evaluating the mechanisms underlying visceral hypersensitivity.
Assuntos
Músculos Abdominais/fisiologia , Ansiedade de Separação/psicologia , Privação Materna , Animais , Peso Corporal/fisiologia , Cateterismo , Eletrodos Implantados , Eletromiografia , Eletrofisiologia , Feminino , Manobra Psicológica , Contração Muscular/fisiologia , Ratos , Ratos Long-Evans , Reto/fisiologia , Estresse Psicológico/fisiopatologia , TelemetriaRESUMO
BACKGROUND: There is an inverse relationship between gestational age, birth weight and the time of first neonatal bowel movement. The authors hypothesized that delayed passage of meconium might result from a delayed maturation of the recto-anal inhibitory reflex (RAIR) in premature infants. OBJECTIVE: To evaluate whether the RAIR is absent in very preterm infants 28-32 weeks postmenstrual age with delayed meconium production. STUDY DESIGN: Anorectal manometry was performed in 10 preterm infants (seven male) with delayed meconium production (no meconium in the first 48 hours). Median postmenstrual age was 30 weeks (28-31 weeks). Birth weight ranged from 780 to 1930 g (median, 1395 g). A micromanometric assembly (outer diameter, 2.0 mm) was used which incorporated a 1.5-cm-long sleeve sensor for measurement of resting anal sphincter pressure and relaxation. Four side-holes recorded anal and rectal pressures. Rectal distension was performed with direct air insufflation to elicit the RAIR. RESULTS: The time from birth to passage of meconium ranged from 48 to 105 hours (median, 82 hours). The mean anal sphincter pressure, rectal pressure, and anal sphincter oscillation frequency were 22.0 +/- 5.0 mm Hg, 6.9 +/- 2.0 mm Hg, and 9.8 +/- 1.9/min, respectively. A normal RAIR was elicited in all infants. CONCLUSION: Anorectal manometry recordings in premature infants with delayed passage of meconium showed normal anorectal pressures and a normal RAIR, suggesting that delayed meconium passage is not related to the absence of a RAIR.
Assuntos
Canal Anal/fisiologia , Recém-Nascido Prematuro/fisiologia , Inibição Neural/fisiologia , Reto/fisiologia , Reflexo/fisiologia , Canal Anal/inervação , Canal Anal/fisiopatologia , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Manometria , Mecônio , Pressão , Reto/inervação , Reto/fisiopatologiaRESUMO
The Ussing chamber technique has contributed significantly to our understanding of the role of ion transport in the pathogenesis of human diseases like cystic fibrosis (CF). Here, we summarize protocols developed to study the Cl- channel function of the cystic fibrosis transmembrane conductance regulator (CFTR) protein in rectal biopsies from normal individuals and CF patients. These protocols can be applied to study the function and pharmacological modulation of wild-type and mutant CFTR in the context of the native epithelium. Together with sweat testing and genetic analyses, these functional measurements may aid in establishing a diagnosis of CF.
Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/fisiologia , Fibrose Cística/fisiopatologia , Reto/fisiologia , Biópsia , Cloretos/fisiologia , Fibrose Cística/diagnóstico , Humanos , Transporte de Íons/fisiologia , Técnicas de Patch-Clamp/métodos , Reto/patologiaRESUMO
Rectal sensation is used as an investigative tool in the diagnosis of anorectal pathology. However, the data obtained are subjective depending on the patient's perception of the sensation. We investigated the hypothesis that sympathetic skin response (SSR) can be used as a tool for objective assessment of the rectal sensation. The SSR was recorded in 24 healthy volunteers (age 37.2 years, 14 men) using a surface electrode applied to the skin of the palmar surface of the subject's hand and a reference electrode to the dorsum of the same hand. The EMG activity of the pelvic floor muscles was registered by a surface electrode fixed to the perineal skin. The subject was asked before and after individual anesthetization of the rectum and palm to report the first rectal and urge sensations during balloon filling of the rectum in increments of 10 ml of saline. Low volume rectal distension effected no sympathetic skin or pelvic floor responses, while larger volumes produced the response. The skin and pelvic floor responses occurred with every rectal sensation and corresponded with the volunteers' subjective perception. Urge suppression was associated with synchronous decrease of skin and pelvic floor responses which disappeared on balloon expulsion. Rectal balloon distension, 20 minutes after individual anesthetization of the rectum or palm produced no palm skin response, which returned however 3 hours later. A novel approach which can objectively define subjective perceptions arising from the rectum has been identified. Rectal sensations produce coordinated sympathetic skin response and pelvic floor activity which seem to be mediated through a reflex which we term the "recto-palmar reflex". Further studies are required to investigate the role of this reflex in defection and sympathetic disorders.