Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 225
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38718813

RESUMO

Objective.This study aims to characterize radiological properties of selected additive manufacturing (AM) materials utilizing both material extrusion and vat photopolymerization technologies. Monochromatic synchrotron x-ray images and synchrotron treatment beam dosimetry were acquired at the hutch 3B and 2B of the Australian Synchrotron-Imaging and Medical Beamline.Approach.Eight energies from 30 keV up to 65 keV were used to acquire the attenuation coefficients of the AM materials. Comparison of theoretical, and experimental attenuation data of AM materials and standard solid water for MV linac was performed. Broad-beam dosimetry experiment through attenuated dose measurement and a Geant4 Monte Carlo simulation were done for the studied materials to investigate its attenuation properties specific for a 4 tesla wiggler field with varying synchrotron radiation beam qualities.Main results.Polylactic acid (PLA) plus matches attenuation coefficients of both soft tissue and brain tissue, while acrylonitrile butadiene styrene, Acrylonitrile styrene acrylate, and Draft resin have close equivalence to adipose tissue. Lastly, PLA, co-polyester plus, thermoplastic polyurethane, and White resins are promising substitute materials for breast tissue. For broad-beam experiment and simulation, many of the studied materials were able to simulate RMI457 Solid Water and bolus within ±10% for the three synchrotron beam qualities. These results are useful in fabricating phantoms for synchrotron and other related medical radiation applications such as orthovoltage treatments.Significance and conclusion.These 3D printing materials were studied as potential substitutes for selected tissues such as breast tissue, adipose tissue, soft-tissue, and brain tissue useful in fabricating 3D printed phantoms for synchrotron imaging, therapy, and orthovoltage applications. Fabricating customizable heterogeneous anthropomorphic phantoms (e.g. breast, head, thorax) and pre-clinical animal phantoms (e.g. rodents, canine) for synchrotron imaging and radiotherapy using AM can be done based on the results of this study.


Assuntos
Síncrotrons , Austrália , Método de Monte Carlo , Radioterapia/instrumentação , Radioterapia/métodos , Radiometria/instrumentação , Radiometria/métodos , Humanos
2.
BMC Oral Health ; 24(1): 396, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549137

RESUMO

BACKGROUND: The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. METHODS: Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N - 90º, 100 N - 90º, 200 N - 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 µm. RESULTS: Microgaps were present in all implant systems prior to loading (0.15-9 µm). Values increased with mounting force and angle up to 40.5 µm at an off axis loading of 100 N in a 90° angle. CONCLUSIONS: In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.


Assuntos
Implantes Dentários , Síncrotrons , Humanos , Projeto do Implante Dentário-Pivô , Simulação por Computador , Dente Suporte , Análise do Estresse Dentário
3.
Phys Med ; 118: 103209, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38281410

RESUMO

In-beam PET (Positron Emission Tomography) is one of the most precise techniques for in-vivo range monitoring in hadron therapy. Our objective was to demonstrate the feasibility of a short irradiation run for range verification before a carbon-ion treatment. To do so a PMMA target was irradiated with a 220 MeV/u carbon-ion beam and annihilation coincidences from short-lived positron emitters were acquired after irradiations lasting 0.6 s. The experiments were performed at the synchrotron-based facility CNAO (Italian National Center of Oncological Hadrontherapy) by using the INSIDE in-beam PET detector. The results show that, with 3·107 carbon ions, the reconstructed positron emitting nuclei distribution is in good agreement with the predictions of a detailed FLUKA Monte Carlo study. Moreover, the radio-nuclei production is sufficiently abundant to determine the average ion beam range with a σ of 1 mm with a 6 s measurement of the activity distribution. Since the data were acquired when the beam was off, the proposed rapid calibration method can be applied to hadron beams extracted from accelerators with very different time structures.


Assuntos
Elétrons , Radioterapia com Íons Pesados , Tomografia por Emissão de Pósitrons/métodos , Carbono/uso terapêutico , Síncrotrons , Método de Monte Carlo
4.
Phys Med Biol ; 69(5)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38295408

RESUMO

Objective.Spatially-fractionated radiotherapy (SFRT) delivered with a very-high-energy electron (VHEE) beam and a mini-GRID collimator was investigated to achieve synergistic normal tissue-sparing through spatial fractionation and the FLASH effect.Approach.A tungsten mini-GRID collimator for delivering VHEE SFRT was optimized using Monte Carlo (MC) simulations. Peak-to-valley dose ratios (PVDRs), depths of convergence (DoCs, PVDR ≤ 1.1), and peak and valley doses in a water phantom from a simulated 150 MeV VHEE source were evaluated. Collimator thickness, hole width, and septal width were varied to determine an optimal value for each parameter that maximized PVDR and DoC. The optimized collimator (20 mm thick rectangular prism with a 15 mm × 15 mm face with a 7 × 7 array of 0.5 mm holes separated by 1.1 mm septa) was 3D-printed and used for VHEE irradiations with the CERN linear electron accelerator for research beam. Open beam and mini-GRID irradiations were performed at 140, 175, and 200 MeV and dose was recorded with radiochromic films in a water tank. PVDR, central-axis (CAX) and valley dose rates and DoCs were evaluated.Main results.Films demonstrated peak and valley dose rates on the order of 100 s of MGy/s, which could promote FLASH-sparing effects. Across the three energies, PVDRs of 2-4 at 13 mm depth and DoCs between 39 and 47 mm were achieved. Open beam and mini-GRID MC simulations were run to replicate the film results at 200 MeV. For the mini-GRID irradiations, the film CAX dose was on average 15% higher, the film valley dose was 28% higher, and the film PVDR was 15% lower than calculated by MC.Significance.Ultimately, the PVDRs and DoCs were determined to be too low for a significant potential for SFRT tissue-sparing effects to be present, particularly at depth. Further beam delivery optimization and investigations of new means of spatial fractionation are warranted.


Assuntos
Elétrons , Dosimetria Fotográfica , Método de Monte Carlo , Dosimetria Fotográfica/métodos , Síncrotrons , Carmustina , Água , Dosagem Radioterapêutica , Radiometria
5.
Radiat Prot Dosimetry ; 199(15-16): 1910-1916, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819290

RESUMO

ELI Beamlines is one of the pillars of the Extreme Light Infrastructure European Research Infrastructure Consortium (ELI ERIC), the European project aiming at building the next generation of high power lasers for fundamental research and industrial applications. Several high-power lasers are hosted by the ELI Beamlines facility. Even at a power lower than the nominal one, when interacting with a target, the laser can generate mixed ionizing radiation fields of unique nature. One of the major laser systems, High-repetition-rate advanced petawatt laser system (HAPLS) was already used in commissioning experiments. Detecting the neutrons generated during these experiments has been a challenging task, since certain difficulties were faced. First, the experimental conditions were frequently altered during the commissioning phase (such as laser beam parameters, experimental geometry or target type). Next, the extremely short duration of the ionizing radiation pulse generated by the laser (~10-14 s) complicated the correct interpretation of the data provided by the detectors designed and calibrated in standard fields. Here, one commissioning experiment is described, together with the means of addressing the problem of the detection of the ionizing radiation and the lessons learned in this endeavour.


Assuntos
Radiação Ionizante , Síncrotrons , Lasers , Nêutrons
6.
J Synchrotron Radiat ; 30(Pt 6): 1076-1085, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815374

RESUMO

Microbeam radiation therapy (MRT) is a radiotherapy technique combining spatial fractionation of the dose distribution on a micrometric scale, X-rays in the 50-500 keV range and dose rates up to 16 × 103 Gy s-1. Nowadays, in vivo dosimetry remains a challenge due to the ultra-high radiation fluxes involved and the need for high-spatial-resolution detectors. The aim here was to develop a striped diamond portal detector enabling online microbeam monitoring during synchrotron MRT treatments. The detector, a 550 µm bulk monocrystalline diamond, is an eight-strip device, of height 3 mm, width 178 µm and with 60 µm spaced strips, surrounded by a guard ring. An eight-channel ASIC circuit for charge integration and digitization has been designed and tested. Characterization tests were performed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility (ESRF). The detector measured direct and attenuated microbeams as well as interbeam fluxes with a precision level of 1%. Tests on phantoms (RW3 and anthropomorphic head phantoms) were performed and compared with simulations. Synchrotron radiation measurements were performed on an RW3 phantom for strips facing a microbeam and for strips facing an interbeam area. A 2% difference between experiments and simulations was found. In more complex geometries, a preliminary study showed that the absolute differences between simulated and recorded transmitted beams were within 2%. Obtained results showed the feasibility of performing MRT portal monitoring using a microstriped diamond detector. Online dosimetric measurements are currently ongoing during clinical veterinary trials at ESRF, and the next 153-strip detector prototype, covering the entire irradiation field, is being finalized at our institution.


Assuntos
Radiometria , Síncrotrons , Radiometria/métodos , Fracionamento da Dose de Radiação , Raios X , Imagens de Fantasmas , Radioterapia , Método de Monte Carlo , Diamante
7.
Phys Med Biol ; 68(24)2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37549670

RESUMO

Objective. Non-primary radiation doses to normal tissues from proton therapy may be associated with an increased risk of secondary malignancies, particularly in long-term survivors. Thus, a systematic method to evaluate if the dose level of non-primary radiation meets the IEC standard requirements is needed.Approach. Different from the traditional photon radiation therapy system, proton therapy systems are composed of several subsystems in a thick bunker. These subsystems are all possible sources of non-primary radiation threatening the patient. As a case study, 7 sources in the P-Cure synchrotron-based proton therapy system are modeled in Monte Carlo (MC) code: tandem injector, injection, synchrotron ring, extraction, beam transport line, scanning nozzle and concrete reflection/scattering. To accurately evaluate the synchrotron beam loss and non-primary dose, a new model called the torus source model is developed. Its parametric equations define the position and direction of the off-orbit particle bombardment on the torus pipe shell in the Cartesian coordinate system. Non-primary doses are finally calculated by several FLUKA simulations.Main results. The ratios of summarized non-primary doses from different sources to the planned dose of 2 Gy are all much smaller than the IEC requirements in both the 15-50 cm and 50-200 cm regions. Thus, the P-Cure synchrotron-based proton therapy system is clean and patient-friendly, and there is no need an inner shielding concrete between the accelerator and patient.Significance. Non-primary radiation dose level is a very important indicator to evaluate the quality of a PT system. This manuscript provides a feasible MC procedure for synchrotron-based proton therapy with new beam loss model. Which could help people figure out precisely whether this level complies with the IEC standard before the system put into clinical treatment. What' more, the torus source model could be widely used for bending magnets in gantries and synchrotrons to evaluate non-primary doses or other radiation doses.


Assuntos
Terapia com Prótons , Humanos , Doses de Radiação , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Síncrotrons , Método de Monte Carlo , Dosagem Radioterapêutica
8.
Phys Med ; 112: 102643, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37523926

RESUMO

A Geant4 based simulation platform of the Holland Proton Therapy Centre (HollandPTC, Netherlands) R&D beamline (G4HPTC-R&D) was developed to enable the planning, optimisation and advanced dosimetry for radiobiological studies. It implemented a six parameter non-symmetrical Gaussian pencil beam surrogate model to simulate the R&D beamline in both a pencil beam and passively scattered field configuration. Three different experimental proton datasets (70 MeV, 150 MeV, and 240 MeV) of the pencil beam envelope evolution in free air and depth-dose profiles in water were used to develop a set of individual parameter surrogate functions to enable the modelling of the non-symmetrical Gaussian pencil beam properties with only the ProBeam isochronous cyclotron mean extraction proton energy as input. This refined beam model was then benchmarked with respect to three independent experimental datasets of the R&D beamline operating in both a pencil beam configuration at 120 and 200 MeV, and passively scattered field configuration at 150 MeV. It was shown that the G4HPTC-R&D simulation platform can reproduce the pencil beam envelope evolution in free air and depth-dose profiles to within an accuracy on the order of ±5% for all tested energies, and that it was able to reproduce the 150 MeV passively scattered field to the specifications need for clinical and radiobiological applications.


Assuntos
Terapia com Prótons , Prótons , Método de Monte Carlo , Terapia com Prótons/métodos , Simulação por Computador , Síncrotrons , Dosagem Radioterapêutica
9.
Med Phys ; 50(10): 6543-6553, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37287315

RESUMO

BACKGROUND: Electron synchrotrons produce x-ray beams with dose rates orders of magnitude greater than conventional x-ray tubes and with beam sizes on the order of a few millimeters. These characteristics put severe challenges on current dosimeters to accurately realize absorbed dose or air kerma. PURPOSE: This work seeks to investigate the suitability of a novel aluminum-based calorimeter to determine absorbed dose to water with an uncertainty significantly smaller than currently possible with conventional detectors. A lower uncertainty in the determination of absolute dose rate would impact both therapeutic applications of synchrotron-produced x-ray beams and research investigations. METHODS: A vacuum-based calorimeter prototype with an aluminum core was built, matching the beam profile of the 140 keV monochromatic x-ray beam, produced by the Canadian Light Source Biomedical Imaging and Therapy beamline. The choice of material and overall calorimeter design was optimized using FEM thermal modeling software while Monte Carlo radiation transport simulations were used to model the impact of interactions of the radiation beam with the detector components. RESULTS: Corrections for both the thermal conduction and radiation transport effects were of the order of 3% and the simplicity of the geometry, combined with the monochromatic nature of the incident x-ray beam, meant that the uncertainty in each correction was ≤0.5%. The calorimeter performance was found to be repeatable over multiple irradiations of 1 Gy at the ± 0.6% level, and no systematic dependence on environmental effects or total dose was observed. CONCLUSION: The combined standard uncertainty in the determination of absorbed dose to aluminum was estimated to be 0.8%, indicating that absorbed dose to water, the ultimate quantity of interest, could be determined with an uncertainty on the order of 1%. This value is an improvement over current techniques used for synchrotron dosimetry and comparable with the state-of-the art for conventional kV x-ray dosimetry.


Assuntos
Alumínio , Síncrotrons , Raios X , Canadá , Radiometria/métodos , Água , Método de Monte Carlo
10.
Phys Med Biol ; 68(15)2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37369231

RESUMO

Objective. To commission a proton, double-scattering FLASH beamline by maximizing efficiency and field size, enabling higher-linear energy transfer FLASH radiotherapy to cells and small animals using a spread-out Bragg peak (SOBP) treatment configuration. We further aim to provide a configuration guide for the design of future FLASH proton double-scattering (DS) beamlines.Approach. Beam spot size and spread were measured with film and implemented into TOol for PArticle Simulation (TOPAS). Monte Carlo simulations were optimized to verify the ideal positioning, dimensions, and material of scattering foils, secondary scatterers, ridge filters, range compensators, and apertures. A ridge filter with three discrete heights was used to create a spread-out Bragg peak (SOBP) and was experimentally verified using our in-house experimental FLASH beamline. The increase in dose rate was compared to nominal shoot-through techniques.Results. The configuration and scatterer distance producing the largest field size of acceptable flatness, without drastically compromising dose rate was determined to be an elliptical field of 2 cm × 1.5 cm (25% larger than a previous configuration). SOBP testing yielded three distinct but connected spikes in dose with flatness under 5%. Reducing the thickness of the (first) scattering foil by a factor of two was found to increase efficiency by 50%. The new settings increased the field size, provided a Bragg peak treatment option, and increased the maximum available dose rate by 85%, as compared to the previous, shoot through method.Significance. Beam line updates established FLASH dose rates of over 135 Gy s-1(potentially higher) at our double-scattering beamline, increased the efficiency and field size, and enabled SOBP treatments by incorporating an optimized ridge filter. Based on our simulations we provide parametric suggestions when commissioning a new proton DS beamline. This enhanced FLASH beamline for SOBP irradiations with higher dose rates and larger field sizes will enable a wider variety of experimentation in future studies.


Assuntos
Terapia com Prótons , Prótons , Animais , Síncrotrons , Simulação por Computador , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Método de Monte Carlo
11.
Anal Chim Acta ; 1266: 341352, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37244662

RESUMO

The development of quantitative analytical methods to assess the heterogeneous distribution and penetration of nanodrugs in solid tumors is of great importance for anticancer nanomedicine. Herein, Expectation-Maximization (EM) iterate algorithm and threshold segmentation methods were used to visualize and quantify the spatial distribution patterns, penetration depth and diffusion features of two-sized hafnium oxide nanoparticles (s-HfO2 NPs in 2 nm and l-HfO2 NPs in 50 nm sizes) in mouse models of breast cancer using synchrotron radiation micro-computed tomography (SR-µCT) imaging technique. The three-dimensional (3D) SR-µCT images were reconstructed based on the EM iterate algorithm thus clearly displayed the size-related penetration and distribution within the tumors after intra-tumoral injection of HfO2 NPs and X-ray irradiation treatment. The obtained 3D animations clearly show that a considerable amount of s-HfO2 and l-HfO2 NPs diffused into tumor tissues at 2 h post-injection and displayed the obvious increase in the tumor penetration and distribution area within the tumors at day 7 after combination with low-dose X-ray irradiation treatment. A thresholding segmentation for 3D SR-µCT image was developed to assess the penetration depth and quantity of HfO2 NPs along the injection sites in tumors. The developed 3D-imaging techniques revealed that the s-HfO2 NPs presented more homogeneous distribution pattern, diffused more quickly and penetrated more deeply within tumor tissues than the l-HfO2 NPs did. Whereas, the low-dose X-ray irradiation treatment greatly enhanced the wide distribution and deep penetration of both s-HfO2 and l-HfO2 NPs. This developed method may provide quantitative distribution and penetration information for the X-ray sensitive high-Z metal nanodrugs in the cancer imaging and therapy.


Assuntos
Nanopartículas , Neoplasias , Camundongos , Animais , Microtomografia por Raio-X , Síncrotrons , Imageamento Tridimensional/métodos
12.
J Radiol Prot ; 43(2)2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37257434

RESUMO

Iranian Light Source Facility (ILSF) is an under-construction synchrotron radiation accelerator consisting of a 150 MeV linac, a booster synchrotron operating from 150 MeV to 3 GeV, and a 3 GeV storage ring that stores a maximum of 400 mA current of electrons. As the stored beam circulates, a fraction of the beam is lost due to interactions with gas molecules, interactions among beam particles, and orbital bending, which produce radiation. The bulk shielding calculation for the ILSF and the input parameters used for this analysis are discussed in this paper. The potential of skyshine neutrons to cause radiation hazards is investigated as well. Moreover, the design and shielding simulation using the FLUKA Monte Carlo code is presented for the linac beam stop and primary and scattered gas bremsstrahlung for the first optics enclosure of the ILSF spectro microscopy beamline. Our designed radiation shielding system guarantees that the annual dose in all areas around the ILSF machine does not exceed the dose limit of 1 mSv.


Assuntos
Simulação por Computador , Proteção Radiológica , Síncrotrons , Irã (Geográfico) , Método de Monte Carlo , Nêutrons , Doses de Radiação , Síncrotrons/instrumentação , Síncrotrons/normas , Elétrons
13.
Sci Rep ; 13(1): 5643, 2023 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-37024527

RESUMO

Synchrotron X-ray computed tomography (XCT) has been increasingly applied to study the in vivo dynamics of root growth and rhizosphere processes. However, minimizing radiation-induced damage to root growth warrants further investigation. Our objective was to develop a robust approach for modeling and evaluating ways to reduce synchrotron X-ray dose effects on root growth during in vivo imaging. Wheat roots growing in soil were exposed to X-rays during XCT experiments resolved in space (3D) plus time (4D). The dose rate and cumulative absorbed dose in roots were modelled using the Monte Carlo code FLUKA for different experimental conditions of polychromatic and quasi-monochromatic X-ray beam configurations. The most impactful factors affecting damage to roots were incident X-ray energy spectrum, stored current in the accelerator machine, position of the root in the soil, and possibly the number of exposures during the 4D XCT experiments. Our results imply that radiation dose during in vivo imaging of plant roots can be diminished by using monochromatic radiation at the highest energy suitable for a given sample thickness and field of view, and by controlling the rotation axis of off-centered roots to increase attenuation of radiation by the soil matrix.


Assuntos
Solo , Síncrotrons , Raios X , Método de Monte Carlo , Radiografia , Imagens de Fantasmas
14.
J Synchrotron Radiat ; 30(Pt 3): 627-633, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37026390

RESUMO

Palaeohistological analysis has numerous applications in understanding the palaeobiology of extinct dinosaurs. Recent developments of synchrotron-radiation-based X-ray micro-tomography (SXMT) have allowed the non-destructive assessment of palaeohistological features in fossil skeletons. Yet, the application of the technique has been limited to specimens on the millimetre to micrometre scale because its high-resolution capacity has been obtained at the expense of a small field of view and low X-ray energy. Here, SXMT analyses of dinosaur bones with widths measuring ∼3 cm under a voxel size of ∼4 µm at beamline BL28B2 at SPring-8 (Hyogo, Japan) are reported, and the advantages of virtual-palaeohistological analyses with large field of view and high X-ray energy are explored. The analyses provide virtual thin-sections visualizing palaeohistological features comparable with those obtained by traditional palaeohistology. Namely, vascular canals, secondary osteons and lines of arrested growth are visible in the tomography images, while osteocyte lacunae are unobservable due to their micrometre-scale diameter. Virtual palaeohistology at BL28B2 is advantageous in being non-destructive, allowing multiple sampling within and across skeletal elements to exhaustively test the skeletal maturity of an animal. Continued SXMT experiments at SPring-8 should facilitate the development of SXMT experimental procedures and aid in understanding the paleobiology of extinct dinosaurs.


Assuntos
Dinossauros , Fósseis , Animais , Dinossauros/anatomia & histologia , Síncrotrons , Raios X , Microtomografia por Raio-X/métodos
15.
Phys Med ; 107: 102551, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36867911

RESUMO

PURPOSE: An ocular applicator that fits a commercial proton snout with an upstream range shifter to allow for treatments with sharp lateral penumbra is described. MATERIALS AND METHODS: The validation of the ocular applicator consisted of a comparison of range, depth doses (Bragg peaks and spread out Bragg peaks), point doses, and 2-D lateral profiles. Measurements were made for three field sizes, 1.5, 2, and 3 cm, resulting in 15 beams. Distal and lateral penumbras were simulated in the treatment planning system for seven range-modulation combinations for beams typical of ocular treatments and a field size of 1.5 cm, and penumbra values were compared to published literature. RESULTS: All the range errors were within 0.5 mm. The maximum averaged local dose differences for Bragg peaks and SOBPs were 2.6% and 1.1%, respectively. All the 30 measured point doses were within +/-3% of the calculated. The measured lateral profiles, analyzed through gamma index analysis and compared to the simulated, had pass rates greater than 96% for all the planes. The lateral penumbra increased linearly with depth, from 1.4 mm at 1 cm depth to 2.5 mm at 4 cm depth. The distal penumbra ranged from 3.6 to 4.4 mm and increased linearly with the range. The treatment time for a single 10 Gy (RBE) fractional dose ranged from 30 to 120 s, depending on the shape and size of the target. CONCLUSIONS: The ocular applicator's modified design allows lateral penumbra similar to dedicated ocular beamlines while enabling planners to use modern treatment tools such as Monte Carlo and full CT-based planning with increased flexibility in beam placement.


Assuntos
Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica , Síncrotrons , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos
16.
Phys Med Biol ; 68(5)2023 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-36731141

RESUMO

The Mayo Clinic Florida Integrated Oncology Building will be the home of the first spot-scanning only carbon/proton hybrid therapy system by Hitachi, Ltd. It will provide proton beams up to kinetic energies of 230 MeV and carbon beams up to 430 MeV n-1for clinical deployment. To provide adequate radiation protection, the Geant4 (v10.6) Monte Carlo toolkit was utilized to quantify the ambient dose equivalent at a 10 mm depth (H*(10)) for photons and neutrons. To perform accurate calculations of the ambient dose equivalent, three-dimensional computer-aided design files of the entire planned facility were imported into Geant4, as well as certain particle system components such as the bending magnets, fast Faraday cup, and gantry. Particle fluence was scored using 60 cm diameter spheres, which were strategically placed throughout areas of interests. Analytical calculations were performed as first-pass design checks. Major shielding slabs were optimized using Geant4 simulations iteratively, with more than 20 alternative designs evaluated within Geant4. The 430 MeV n-1carbon beams played the most significant role in concrete thickness Requirements. The primary wall thickness for the carbon fixed beam room is 4 meters. The presence of the proton gantry structure in the simulation caused the ambient dose equivalent to increase by around 67% at the maze entrance, but a decrease in the high energy beam transport corridor. All shielding primary and secondary goals for clinical operations were met per state regulation and national guidelines.


Assuntos
Terapia com Prótons , Radiometria , Radiometria/métodos , Prótons , Terapia com Prótons/métodos , Síncrotrons , Método de Monte Carlo , Nêutrons , Carbono
17.
Phys Med Biol ; 68(6)2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36731142

RESUMO

Objective. The radiation response of alanine is very well characterized in the MV photon energy range where it can be used to determine the dose delivered with an accuracy better than 1%, making it suitable as a secondary standard detector in cancer radiation therapy. This is not the case in the very low energy keV x-ray range where the alanine response is affected by large uncertainties and is strongly dependent on the x-ray beam energy. This motivated the study undertaken here.Approach. Alanine pellets with a nominal thickness of 0.5 mm and diameter of 5 mm were irradiated with monoenergetic x-rays at the Diamond Light Source synchrotron, to quantify their response in the 8-20 keV range relative to60Co radiation. The absorbed dose to graphite was measured with a small portable graphite calorimeter, and the DOSRZnrc code in the EGSnrc Monte Carlo package was used to calculate conversion factors between the measured dose to graphite and the absorbed dose to water delivered to the alanine pellets. GafChromic EBT3 films were used to measure the beam profile for modelling in the MC simulations.Main results. The relative responses measured in this energy range were found to range from 0.616 to 0.643, with a combined relative expanded uncertainty of 3.4%-3.5% (k= 2), where the majority of the uncertainty originated from the uncertainty in the alanine readout, due to the small size of the pellets used.Significance. The measured values were in good agreement with previously published data in the overlapping region of x-ray energies, while this work extended the dataset to lower energies. By measuring the response to monoenergetic x-rays, the response to a more complex broad-spectrum x-ray source can be inferred if the spectrum is known, meaning that this work supports the establishment of alanine as a secondary standard dosimeter for low-energy x-ray sources.


Assuntos
Alanina , Síncrotrons , Raios X , Alanina/metabolismo , Alanina/efeitos da radiação , Braquiterapia , Grafite , Método de Monte Carlo , Neoplasias/radioterapia , Radiometria/métodos , Incerteza , Humanos
18.
Z Med Phys ; 33(4): 542-551, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36357294

RESUMO

PURPOSE: To evaluate the dosimetric accuracy for small field proton irradiation relevant for pre-clinical in vivo studies using clinical infrastructure and technology. In this context additional beam collimation and range reduction was implemented. METHODS AND MATERIALS: The clinical proton beam line employing pencil beam scanning (PBS) was adapted for the irradiation of small fields at shallow depths. Cylindrical collimators with apertures of 15, 12, 7 and 5mm as well as two different range shifter types, placed at different distances relative to the target, were tested: a bolus range shifter (BRS) attached to the collimator and a clinical nozzle mounted range shifter (CRS) placed at a distance of 72cm from the collimator. The Monte Carlo (MC) based dose calculation engine implemented in the clinical treatment planning system (TPS) was commissioned for these two additional hardware components. The study was conducted with a phantom and cylindrical target sizes between 2 and 25mm in diameter following a dosimetric end-to-end test concept. RESULTS: The setup with the CRS provided a uniform dose distribution across the target. An agreement of better than5% between the planned dose and the measurements was obtained for a target with 3mm diameter (collimator 5mm). A 2mm difference between the collimator and the target diameter (target being 2 mm smaller than the collimator) sufficed to cover the whole target with the planned dose in the setup with CRS. Using the BRS setup (target 8mm, collimator 12mm) resulted in non-homogeneous dose distributions, with a dose discrepancy of up to 10% between the planned and measured doses. CONCLUSION: The clinical proton infrastructure with adequate beam line adaptations and a state-of-the-art TPS based on MC dose calculations enables small animal irradiations with a high dosimetric precision and accuracy for target sizes down to 3mm.


Assuntos
Terapia com Prótons , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Terapia com Prótons/métodos , Síncrotrons , Imagens de Fantasmas , Método de Monte Carlo
19.
J Bone Miner Res ; 37(11): 2244-2258, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36069373

RESUMO

Cortical bone remodeling is carried out by basic multicellular units (BMUs), which couple resorption to formation. Although fluorochrome labeling has facilitated study of BMU formative parameters since the 1960s, some resorptive parameters, including the longitudinal erosion rate (LER), have remained beyond reach of direct measurement. Indeed, our only insights into this spatiotemporal parameter of BMU behavior come from classical studies that indirectly inferred LER. Here, we demonstrate a 4D in vivo method to directly measure LER through in-line phase contrast synchrotron imaging. The tibias of rabbits (n = 15) dosed daily with parathyroid hormone were first imaged in vivo (synchrotron micro-CT; day 15) and then ex vivo 14 days later (conventional micro-CT; day 29). Mean LER assessed by landmarking the co-registered scans was 23.69 ± 1.73 µm/d. This novel approach holds great promise for the direct study of the spatiotemporal coordination of bone remodeling, its role in diseases such as osteoporosis, as well as related treatments. © 2022 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).


Assuntos
Osteoporose , Síncrotrons , Animais , Coelhos , Osso e Ossos , Osso Cortical/diagnóstico por imagem , Remodelação Óssea , Densidade Óssea
20.
Water Environ Res ; 94(7): e10759, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35796043

RESUMO

The pollutants released from pharmaceutical, steel, paper, and battery industries into water cause stress on the natural ecosystems, may mix with soil and water, enter into human food chain, and hence cause irreparable damage to the biotic system. Hence, the appropriate monitoring of water along with determination of heavy metals is very important for human beings. In present paper, total reflection X-ray fluorescence (TXRF) spectrometry technique is employed to determine the level of different contaminants in the water samples gathered from the various sites of an identified industrial area. Experimentation is carried out at Raja Ramanna Centre for Advanced Technology (RRCAT), Indore-India by using TXRF, which is one the advance techniques of element determination up to ppb levels. The elemental concentration of Cl, K, Ca, Fe, Cu, Zn, Ga, Br, Sr, As, Pb, and Ni is quantified and compared with the limits established by the WHO (World Health Organization) and BIS (Bureau of Indian Standard) guidelines regarding drinking water use. The levels of the Pb, Fe, As, Ni, Cr, Co, and Mn exceeded the values suggested by WHO and BIS at some locations/sites. To better understand the situation, water quality parameters such as Water Quality Index (WQI), Heavy metal Pollution Index (HPI), Contamination Index (CI), Metal Enrichment Index (MEI), and Heavy Metal Evaluation Index (HEI) have also been assessed for all the sites close to industrial hub. Among all sites except at A3 and A6, WQI is found to be much greater than WHO and BIS established limit. Level of arsenic in the water at A1 location was found 73 ppb. However, lead metal in water was found to be very high at all the six studied locations, and at A1 location, it is found extremely high 2613 ppb. Therefore, water at A1 and A2 sites is found to be unfit for drinking. PRACTITIONER POINTS: Total reflection X-ray fluorescence (TXRF) spectrometry technique is employed to determine the level of different contaminants in the water samples The elemental concentration of Cl, K, Ca, Fe, Cu, Zn, Ga, Br, Sr, As, Pb, and Ni is quantified and compared with the limits prescribed by the WHO Water Quality Index (WQI), Heavy metal Pollution Index (HPI), Contamination Index (CI), Metal Enrichment Index (MEI), and Heavy Metal Enrichment Index (MEI) have also been assessed for all the sites Water at some sites is found unfit for drinking purpose. Based on the observations, some remedial measures are suggested to reduce the level of water contaminants up to desired levels.


Assuntos
Metais Pesados , Poluentes Químicos da Água , Ecossistema , Monitoramento Ambiental/métodos , Humanos , Chumbo , Metais Pesados/análise , Síncrotrons , Poluentes Químicos da Água/análise , Qualidade da Água , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA