Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Int J Toxicol ; 39(3_suppl): 127S-144S, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33203267

RESUMO

The Expert Panel for Cosmetic Ingredient Safety (Panel) reviewed the safety of Hydrolyzed Silk and 9 other silk protein ingredients, which function primarily as skin and hair conditioning agents and bulking agents in cosmetic products. The Panel reviewed relevant data relating to the safety of these ingredients and concluded that 8 ingredients are safe in the present practices of use and concentration in cosmetics, as described in this safety assessment, but that the available data are insufficient for determining the safety of 2 silk protein ingredients in cosmetic products, MEA-Hydrolyzed Silk and Silkworm Cocoon Extract.


Assuntos
Cosméticos , Seda , Animais , Produtos Biológicos/efeitos adversos , Produtos Biológicos/química , Produtos Biológicos/toxicidade , Qualidade de Produtos para o Consumidor , Cosméticos/efeitos adversos , Cosméticos/química , Cosméticos/toxicidade , Feminino , Cobaias , Humanos , Masculino , Camundongos , Ratos , Seda/efeitos adversos , Seda/química , Seda/toxicidade , Testes de Toxicidade
2.
Int J Biol Macromol ; 149: 513-521, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-31954780

RESUMO

Skin and soft tissue infections are major concerns with respect to wound repair. Recently, anti-bacterial wound dressings have been emerging as promising candidates to reduce infection, thus accelerating the wound healing process. This paper presents our work to develop and characterize poly(vinyl alcohol) (PVA)/chitosan (CS)/silk sericin (SS)/tetracycline (TCN) porous nanofibers, with diameters varying from 305 to 425 nm, both in vitro and in vivo for potential applications as wound dressings. The fabricated nanofibers possess a considerable capacity to take up water through swelling (~325-650%). Sericin addition leads to increased hydrophilicity and elongation at break while decreasing fiber diameter and mechanical strength. Moreover, fibroblasts (L929) cultured on the nanofibers with low sericin content (PVA/CS/1-2SS) displayed greater proliferation compared to those on nanofibers without sericin (PVA/CS). Nanofibers loaded with high sericin and tetracycline content significantly inhibited the growth of Escherichia coli and Staphylococcus aureus. In vivo examination revealed that PVA/CS/2SS-TCN nanofibers enhance wound healing, re-epithelialization, and collagen deposition compared to traditional gauze and nanofibers without sericin. The results of this study demonstrate that the PVA/CS/2SS-TCN nanofiber creates a promising alternative to traditional wound dressing materials.


Assuntos
Antibacterianos/farmacologia , Sericinas/farmacologia , Seda/química , Cicatrização/efeitos dos fármacos , Animais , Antibacterianos/química , Bandagens , Quitosana/química , Fibroblastos/efeitos dos fármacos , Humanos , Camundongos , Nanofibras/química , Álcool de Polivinil/química , Sericinas/química , Pele/efeitos dos fármacos , Pele/patologia , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/patogenicidade
3.
Artif Cells Nanomed Biotechnol ; 46(sup1): 394-401, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29336177

RESUMO

A nanofibrous silk nerve conduit has been evaluated for its efficiency based on the promotion of peripheral nerve regeneration in rats. The designed tubes with or without Schwann cells were implanted into a 10 mm gap in the sciatic nerves of the rats. Four months after the surgery, the regenerated nerves were monitored and evaluated by macroscopic assessments and histology. The results demonstrated that the nanofibrous grafts, especially in the presence of Schwann cells, enabled reconstruction of the rat sciatic nerve trunk with a restoration of nerve continuity and formation of nerve fibres with myelination. Histological data demonstrated the presence of Schwann and glial cells in regenerated nerves. This study strongly supports the feasibility of using artificial nerve grafts for peripheral nerve regeneration by bridging large defects in a rat model.


Assuntos
Regeneração Tecidual Guiada/métodos , Nanofibras/química , Regeneração Nervosa/efeitos dos fármacos , Nervo Isquiático/efeitos dos fármacos , Nervo Isquiático/fisiologia , Seda/química , Seda/farmacologia , Animais , Masculino , Ratos , Ratos Wistar
4.
Int J Mol Sci ; 17(8)2016 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-27517919

RESUMO

Silk fibers suffer from microstructural changes due to various external environmental conditions including daily washings. In this paper, we take the backscattering Mueller matrix images of silk samples for non-destructive and real-time quantitative characterization of the wavelength-scale microstructure and examination of the effects of washing by different detergents. The 2D images of the 16 Mueller matrix elements are reduced to the frequency distribution histograms (FDHs) whose central moments reveal the dominant structural features of the silk fibers. A group of new parameters are also proposed to characterize the wavelength-scale microstructural changes of the silk samples during the washing processes. Monte Carlo (MC) simulations are carried out to better understand how the Mueller matrix parameters are related to the wavelength-scale microstructure of silk fibers. The good agreement between experiments and simulations indicates that the Mueller matrix polarimetry and FDH based parameters can be used to quantitatively detect the wavelength-scale microstructural features of silk fibers. Mueller matrix polarimetry may be used as a powerful tool for non-destructive and in situ characterization of the wavelength-scale microstructures of silk based materials.


Assuntos
Detergentes/química , Seda/química , Método de Monte Carlo
5.
Expert Rev Med Devices ; 12(6): 753-62, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26415045

RESUMO

Flow diverter (FD) stents represent a new endovascular technique developed for the treatment of complex intracranial aneurysms (wide neck, fusiform, large, and giant aneurysms) that are challenging for classic endovascular techniques such as coiling, balloon-assisted coiling and stent-assisted coiling. Low porosity, high metal coverage, and high pore density are the main properties of FD stents. These properties induce hemodynamic changes redirecting the blood flow away from the aneurysm and into the parent artery leading to gradual thrombosis of the aneurysm. FD stents also provide scaffolding for subsequent neoendothelial proliferation, and vessel wall remodeling. This is considered as a paradigm shift compared to prior endovascular methods, which predominantly aimed at providing treatment inside the aneurysmal sac. This paper describes in detail the first released FD stent, the Silk flow-diverter stent (Balt Extrusion, Montmorency, France), its mechanism of action and deployment technique. It reviews the pertinent literature regarding safety, efficacy and potential risks and complications associated with the use of this stent.


Assuntos
Procedimentos Endovasculares , Aneurisma Intracraniano/terapia , Seda/química , Stents , Análise Custo-Benefício , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/economia , Humanos , Aneurisma Intracraniano/economia , Complicações Pós-Operatórias/etiologia
6.
Analyst ; 140(3): 779-85, 2015 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-25460852

RESUMO

The demand for methods and technologies capable of rapid, inexpensive and continuous monitoring of health status or exposure to environmental pollutants persists. In this work, the development of novel surface-enhanced Raman spectroscopy (SERS) substrates from metal-coated silk fabric, known as zari, presents the potential for SERS substrates to be incorporated into clothing and other textiles for the routine monitoring of important analytes, such as disease biomarkers or environmental pollutants. Characterization of the zari fabric was completed using scanning electron microscopy, energy dispersive X-ray analysis and Raman spectroscopy. Silver nanoparticles (AgNPs) were prepared, characterized by transmission electron microscopy and UV-vis spectroscopy, and used to treat fabric samples by incubation, drop-coating and in situ synthesis. The quality of the treated fabric was evaluated by collecting the SERS signal of 4,4'-bipyridine on these substrates. When AgNPs were drop-coated on the fabric, sensitive and reproducible substrates were obtained. Adenine was selected as a second probe molecule, because it dominates the SERS signal of DNA, which is an important class of disease biomarker, particularly for pathogens such as Plasmodium spp. and Mycobacterium tuberculosis. Excellent signal enhancement could be achieved on these affordable substrates, suggesting that the developed fabric chips have the potential for expanding the use of SERS as a diagnostic and environmental monitoring tool for application in wearable sensor technologies.


Assuntos
DNA Bacteriano/análise , Nanopartículas Metálicas/química , Seda/análise , Prata/química , Análise Espectral Raman/métodos , Têxteis/análise , Poluentes Ambientais/análise , Microscopia Eletrônica de Varredura/métodos , Microscopia Eletrônica de Transmissão/métodos , Piridinas/química , Seda/química , Seda/economia , Propriedades de Superfície
7.
J Biomed Opt ; 19(10): 106007, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25321399

RESUMO

Polarization measurements are sensitive to the microstructure of tissues and can be used to detect pathological changes. Many tissues contain anisotropic fibrous structures. We obtain the local orientation of aligned fibrous scatterers using different groups of the backscattering Mueller matrix elements. Experiments on concentrically well-aligned silk fibers and unstained human papillary thyroid carcinoma tissues show that the m22 , m33 , m23 , and m32 elements have better contrast but higher degeneracy for the extraction of orientation angles. The m12 and m13 elements show lower contrast, but allow us to determine the orientation angle for the fibrous scatterers along all directions. Moreover, Monte Carlo simulations based on the sphere-cylinder scattering model indicate that the oblique incidence of the illumination beam introduces some errors in the orientation angles obtained by both methods. Mapping the local orientation of anisotropic tissues may not only provide information on pathological changes, but can also give new leads to reduce the orientation dependence of polarization measurements.


Assuntos
Carcinoma Papilar/patologia , Microscopia de Polarização/métodos , Neoplasias da Glândula Tireoide/patologia , Carcinoma Papilar/química , Simulação por Computador , Humanos , Modelos Biológicos , Método de Monte Carlo , Imagens de Fantasmas , Seda/química , Neoplasias da Glândula Tireoide/química
9.
Opt Express ; 18(14): 15104-12, 2010 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-20639995

RESUMO

By comparing the spatially resolved unpolarized, polarized reflectance and Mueller matrix elements of skeletal muscle with a scattering medium containing polystyrene microspheres and silk fibers, we demonstrate that the sphere-cylinder scattering model (SCSM) can reproduce the characteristic features of skeletal muscle. Both experiments and polarization sensitive Monte Carlo simulation provide evidences that SCSM may be used to characterize the structural and optical properties of skeletal muscle.


Assuntos
Modelos Biológicos , Músculo Esquelético/anatomia & histologia , Espalhamento de Radiação , Animais , Bovinos , Simulação por Computador , Método de Monte Carlo , Seda/química
10.
Opt Lett ; 35(14): 2323-5, 2010 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-20634817

RESUMO

We present the experimental results for the two-dimensional backscattering Mueller matrix of a scattering medium containing polystyrene microspheres and silk fibers and simulate the same Mueller matrix using a polarization-sensitive Monte Carlo program with both layered and homogeneous sphere-cylinder scattering models. We discuss the characteristic features in each Mueller matrix element and their relations with the parameters of the spherical and cylindrical scatterers in the medium. Both experiments and simulations suggest that the Mueller matrix elements can be used to characterize the structural and optical properties of anisotropic scattering media.


Assuntos
Refratometria/métodos , Anisotropia , Birrefringência , Simulação por Computador , Luz , Microscopia de Polarização/métodos , Microesferas , Método de Monte Carlo , Nefelometria e Turbidimetria/métodos , Poliestirenos/química , Espalhamento de Radiação , Seda/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA