Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Comput Math Methods Med ; 2022: 9415694, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35035528

RESUMO

An anisotropic diffusion filtering- (ADF-) ultrasound (ADF-U) for ultrasound reconstruction was constructed based on the ADF to explore the diagnostic application of ultrasound imaging based on electronic health (E-health) for cardiac insufficiency and neuronal regulation in patients with sepsis. The 144 patients with sepsis were divided into an experimental group (78 patients with cardiac insufficiency) and a control group (66 patients with normal cardiac function), and another 58 healthy people were included in a blank control. The ultrasound examination was performed on all patients. In addition, new ultrasound image reconstruction and diagnosis were performed based on ADF and E-health, and its reconstruction effects were compared with those of the Bilateral Filter-ultrasonic (BFU) algorithm and the Wavelet Threshold-ultrasonic (WTU) algorithm. The left and right ventricular parameters and neuropeptide levels were detected and recorded. The results show that the running time, average gradient (AG), and peak signal-to-noise ratio (SNR) (PSNR) of the ADF-U algorithm were greater than those of the Bilateral Filter-ultrasonic (BFU) and Wavelet Threshold-ultrasonic (WTU), but the mean square error (MSE) was opposite (P < 0.05); the left ventricular end-systolic volume (LVESV) and the vertical distance between the mitral valve E-point to septal separation (EPSS) in the experimental group were higher than those in the control and blank group, while the left ventricular ejection fraction (LVEF), stroke volume (SV), cardiac output (CO), and left ventricular fractional shortening (LVFS) were opposite (P < 0.05); the systolic peak velocity of right ventricular free wall tricuspid annulus (Sm) and pulmonary valve blood velocity (PVBV) in the experimental group were lower than those of the control group and blank group (P < 0.05); the messenger ribonucleic acid (mRNA) of Proopiomelanocortin (POMC) and Cocain and amphetamine-regulated transcript (CART) was higher than the mRNA IN control group and blank group (P < 0.05). In short, the ADF-U algorithm proposed in this study improved the resolution, SNR, and reconstruction efficiency of E-health ultrasound images and provided an effective reference value for the diagnosis of cardiac insufficiency and neuronal adjustment analysis in patients with sepsis in the emergency department.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Sepse/diagnóstico por imagem , Ultrassonografia/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Biologia Computacional , Serviço Hospitalar de Emergência , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Sistema Nervoso/diagnóstico por imagem , Sistema Nervoso/fisiopatologia , Neuropeptídeos/genética , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Sepse/complicações , Sepse/fisiopatologia , Telemedicina/estatística & dados numéricos , Função Ventricular Esquerda , Função Ventricular Direita , Análise de Ondaletas
2.
J Neurosurg Anesthesiol ; 25(1): 1-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23171854

RESUMO

Standardization and accreditation of fellowship training have been considered in the field of neuroanesthesiology. A prior survey of members of the Society for Neuroscience in Anesthesiology and Critical Care (SNACC) suggested strong support for accreditation and standardization. In response, SNACC created a Task Force that developed curricular guidelines for neuroanesthesiology fellowship training programs. These guidelines represent a first step toward standards for neuroanesthesiology training and will be useful if accreditation is pursued in the future.


Assuntos
Anestesiologia/educação , Currículo , Bolsas de Estudo , Neurocirurgia/educação , Adulto , Criança , Cuidados Críticos , Humanos , Monitorização Intraoperatória , Sistema Nervoso/diagnóstico por imagem , Neurociências/educação , Neurociências/normas , Pediatria , Radiografia
3.
Int J Biomed Comput ; 30(3-4): 275-80, 1992 May.
Artigo em Inglês | MEDLINE | ID: mdl-1634276

RESUMO

Georgetown University Hospital has been operating an image management and communications system (IMACS or PACS) for 3.5 years. This work was initially funded under the Army Medical Research and Development Command Digital Imaging Network Systems (DINS) project. The system was taken from a research system supporting only radiology tasks to one extended to clinical use, and has been used in clinical work for 3 years. This paper will summarize our PACS clinical experience and will describe the operational features implemented and those still necessary.


Assuntos
Sistemas de Informação em Radiologia , Sistemas Computacionais , District of Columbia , Hospitais Universitários , Humanos , Unidades de Terapia Intensiva , Sistema Nervoso/diagnóstico por imagem , Radiografia Abdominal , Serviço Hospitalar de Radiologia , Avaliação da Tecnologia Biomédica , Telemetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA