Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm ; 19(2): 295-305, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34662707

RESUMO

BACKGROUND: Ventricular fibrillation (VF) is characterized by multiple wavelets and rotors. No equation to predict the number of rotors and wavelets observed during fibrillation has been validated in human VF. OBJECTIVE: The purpose of this study was to test the hypothesis that a single equation derived from a Markov M/M/∞ birth-death process could predict the number of rotors and wavelets occurring in human clinical VF. METHODS: Epicardial induced VF (256-electrode) recordings obtained from patients undergoing cardiac surgery were studied (12 patients; 62 epochs). Rate constants for phase singularity (PS) (which occur at the pivot points of rotors) and wavefront (WF) formation and destruction were derived by fitting distributions to PS and WF interformation and lifetimes. These rate constants were combined in an M/M/∞ governing equation to predict the number of PS and WF in VF episodes. Observed distributions were compared to those predicted by the M/M/∞ equation. RESULTS: The M/M/∞ equation accurately predicted average PS and WF number and population distribution, demonstrated in all epochs. Self-terminating episodes of VF were distinguished from VF episodes requiring termination by a trend toward slower PS destruction, slower rates of PS formation, and a slower mixing rate of the VF process, indicated by larger values of the second largest eigenvalue modulus of the M/M/∞ birth-death matrix. The longest-lasting PS (associated with rotors) had shorter interactivation time intervals compared to shorter-lasting PS lasting <150 ms (∼1 PS rotation in human VF). CONCLUSION: The M/M/∞ equation explains the number of wavelets and rotors observed, supporting a paradigm of VF based on statistical fibrillatory dynamics.


Assuntos
Morte Súbita Cardíaca/etiologia , Fibrilação Ventricular/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Mapeamento Epicárdico , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Cadeias de Markov , Modelos Cardiovasculares
2.
Prog Cardiovasc Dis ; 66: 37-45, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34332660

RESUMO

Aortic stenosis is the most common valvulopathy requiring replacement by means of the surgical or transcatheter approach. Transcatheter aortic valve replacement (TAVR) has quickly become a viable and often preferred treatment strategy compared to surgical aortic valve replacement. However, transcatheter heart valve system deployment not infrequently injures the specialized electrical system of the heart, leading to new conduction disorders including high-grade atrioventricular block and complete heart block (CHB) necessitating permanent pacemaker implantation (PPI), which may lead to deleterious effects on cardiac function and patient outcomes. Additional conduction disturbances (e.g., new-onset persistent left bundle branch block, PR/QRS prolongation, and transient CHB) currently lack clearly defined management algorithms leading to variable strategies among institutions. This article outlines the current understanding of the pathophysiology, patient and procedural risk factors, means for further risk stratification and monitoring of patients without a clear indication for PPI, our institutional approach, and future directions in the management and evaluation of post-TAVR conduction disturbances.


Assuntos
Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/efeitos adversos , Potenciais de Ação , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Humanos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
3.
J Am Heart Assoc ; 10(10): e020033, 2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-33960210

RESUMO

Background The temporal incidence of high-grade atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR) is uncertain. As a result, periprocedural monitoring and pacing strategies remain controversial. This study aimed to describe the temporal incidence of initial episode of HAVB stratified by pre- and post-TAVR conduction and identify predictors of delayed events. Methods and Results Consecutive patients undergoing TAVR at a single center between February 2012 and June 2019 were retrospectively assessed for HAVB within 30 days. Patients with prior aortic valve replacement, permanent pacemaker (PPM), or conversion to surgical replacement were excluded. Multivariable logistic regression was performed to assess predictors of delayed HAVB (initial event >24 hours post-TAVR). A total of 953 patients were included in this study. HAVB occurred in 153 (16.1%). After exclusion of those with prophylactic PPM placed post-TAVR, the incidence of delayed HAVB was 33/882 (3.7%). Variables independently associated with delayed HAVB included baseline first-degree atrioventricular block or right bundle-branch block, self-expanding valve, and new left bundle-branch block. Forty patients had intraprocedural transient HAVB, including 16 who developed HAVB recurrence and 6 who had PPM implantation without recurrence. PPM was placed for HAVB in 130 (13.6%) (self-expanding valve, 23.7% versus balloon-expandable valve, 11.9%; P<0.001). Eight (0.8%) patients died by 30 days, including 1 unexplained without PPM present. Conclusions Delayed HAVB occurs with higher frequency in patients with baseline first-degree atrioventricular block or right bundle-branch block, new left bundle-branch block, and self-expanding valve. These findings provide insight into optimal monitoring and pacing strategies based on periprocedural ECG findings.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/epidemiologia , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Minnesota/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Gestão de Riscos
4.
Heart Rhythm ; 18(8): 1406-1413, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33932588

RESUMO

BACKGROUND: Inhomogeneity of ventricular contraction is associated with sudden cardiac death, but the underlying mechanisms are unclear. Alterations in cardiac contraction impact electrophysiological parameters through mechanoelectric feedback. This has been shown to promote arrhythmias in experimental studies, but its effect in the in vivo human heart is unclear. OBJECTIVE: The purpose of this study was to quantify the impact of regional myocardial deformation provoked by a sudden increase in ventricular loading (aortic occlusion) on human cardiac electrophysiology. METHODS: In 10 patients undergoing open heart cardiac surgery, left ventricular (LV) afterload was modified by transient aortic occlusion. Simultaneous assessment of whole-heart electrophysiology and LV deformation was performed using an epicardial sock (240 electrodes) and speckle-tracking transesophageal echocardiography. Parameters were matched to 6 American Heart Association LV model segments. The association between changes in regional myocardial segment length and activation-recovery interval (ARI; a conventional surrogate for action potential duration) was studied using mixed-effect models. RESULTS: Increased ventricular loading reduced longitudinal shortening (P = .01) and shortened ARI (P = .02), but changes were heterogeneous between cardiac segments. Increased regional longitudinal shortening was associated with ARI shortening (effect size 0.20 [0.01-0.38] ms/%; P = .04) and increased local ARI dispersion (effect size -0.13 [-0.23 to -0.03] ms/%; P = .04). At the whole organ level, increased mechanical dispersion translated into increased dispersion of repolarization (correlation coefficient r = 0.81; P = .01). CONCLUSION: Mechanoelectric feedback can establish a potentially proarrhythmic substrate in the human heart and should be considered to advance our understanding and prevention of cardiac arrhythmias.


Assuntos
Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Retroalimentação , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Contração Miocárdica/fisiologia , Idoso , Arritmias Cardíacas/diagnóstico , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
5.
Am J Physiol Heart Circ Physiol ; 320(2): H713-H724, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33337966

RESUMO

The complex pathophysiology of atrial fibrillation (AF) is governed by multiple risk factors in ways that are still elusive. Basic electrophysiological properties, including atrial effective refractory period (AERP) and conduction velocity, are major factors determining the susceptibility of the atrial myocardium to AF. Although there is a great need for affordable animal models in this field of research, in vivo rodent studies are limited by technical challenges. Recently, we introduced an implantable system for long-term assessment of AF susceptibility in ambulatory rats. However, technical considerations did not allow us to perform concomitant supraventricular electrophysiology measurements. Here, we designed a novel quadripolar electrode specifically adapted for comprehensive atrial studies in ambulatory rats. Electrodes were fabricated from medical-grade silicone, four platinum-iridium poles, and stainless-steel fixating pins. Initial quality validation was performed ex vivo, followed by implantation in adult rats and repeated electrophysiological studies 1, 4, and 8 wk postimplantation. Capture threshold was stable. Baseline AERP values (38.1 ± 2.3 and 39.5 ± 2.0 using 70-ms and 120-ms S1-S1 cycle lengths, respectively) confirmed the expected absence of rate adaptation in the unanesthetized state and validated our prediction that markedly higher values reported under anesthesia are nonphysiological. Evaluation of AF substrate in parallel with electrophysiological parameters validated our recent finding of a gradual increase in AF susceptibility over time and demonstrated that this phenomenon is associated with an electrical remodeling process characterized by AERP shortening. Our findings indicate that the miniature quadripolar electrode is a potent new tool, which opens a window of opportunities for better utilization of rats in AF research.NEW & NOTEWORTHY Rodents are increasingly used in AF research. However, technical challenges restrict long-term supraventricular electrophysiology studies in these species. Here, we developed an implantable electrode adapted for such studies in the rat. Our findings indicate that this new tool is effective for long-term follow-up of critical parameters such as atrial refractoriness. Obtained data shed light on the normal electrophysiology and on the increased AF susceptibility that develops in rats with implanted atrial electrodes over time.


Assuntos
Fibrilação Atrial/etiologia , Estimulação Cardíaca Artificial , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Monitorização Ambulatorial/instrumentação , Marca-Passo Artificial , Potenciais de Ação , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Modelos Animais de Doenças , Desenho de Equipamento , Masculino , Valor Preditivo dos Testes , Ratos Sprague-Dawley , Período Refratário Eletrofisiológico , Fatores de Tempo
6.
Heart Rhythm ; 18(3): 419-425, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33250391

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with severe aortic stenosis and high to intermediate surgical risk. However, the proximity of the conduction system to the prosthesis landing zone bears the risk of atrioventricular conduction disorders. The underlying pathophysiology is not fully understood. OBJECTIVE: The purpose of this study was to characterize the impact of TAVI on the conduction system as assessed by simultaneous electrophysiological testing. METHODS: AH and HV intervals and QRS duration were measured using a quadripolar His catheter and surface electrocardiogram in 108 patients at baseline (BL), after balloon predilation (timepoint 1 [T1]), after implantation of the valve prosthesis (T2), and after postdilation, if deemed necessary (T3). RESULTS: Between BL and T2, significant increases of HV interval and QRS duration were observed, with a mean delta of +12.4 ms and +32.7 ms, respectively. Both balloon predilation and valve implantation had an impact on infranodal conduction. No significant increase of AH intervals was documented. The increase of QRS duration led to left bundle branch block (LBBB) in 57 patients (52.8%). Implantation depth positively correlated with QRS prolongation (ρ = 0.21, P = .042) but not with changes of AH or HV interval (ρ = -0.03, P = .762; and ρ = 0.15, P = .130, respectively). CONCLUSION: Electrophysiological testing during TAVI shows impairment of infranodal atrioventricular conduction by balloon predilation and valve implantation. This impairment is positively correlated with valve implantation depth and results in an increase of QRS duration with mainly LBBB pattern on surface electrocardiogram.


Assuntos
Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Monitorização Intraoperatória/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/complicações , Arritmias Cardíacas/fisiopatologia , Fenômenos Eletrofisiológicos , Feminino , Seguimentos , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos
7.
Lupus ; 29(8): 913-923, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32486933

RESUMO

BACKGROUND: There are no data on the influence of disease severity and cardiac autonomic tone on ventricular repolarization and dispersion in 24-hour Holter monitoring in systemic lupus erythematosus (SLE). METHODS: Consecutive 92 SLE and 51 healthy subjects were studied. The standard 12-lead electrocardiography (ECG), Holter monitoring with heart rate turbulence (HRT) and QT, Tp-e and Tp-e/QT ratio assessment (including corrected values) were performed. Subjects with conditions causing repolarization abnormalities or insufficient number of beats suitable for QT evaluation were excluded (17 SLE and 8 controls). RESULTS: Finally, 75 SLE and 43 sex- and age-matched controls were included to the study. In SLE patients, the median disease severity score (Systemic Lupus International Collaborating Clinics/American College of Rheumatology Damage Index (SLICC/ACR-DI)) was 3.0. The mean values of QTc, cTp-e and cTp-e/QTc were significantly higher in SLE patients than in controls. QTc ≥ 460 ms was observed in 18.7% of patients using standard ECG and in 58.7% using Holter monitoring. With Holter monitoring, patients with SLICC/ACR-DI >3.0 presented longer QTc than those with SLICC/ACR-DI ≤3.0 (418±15 vs. 409 ± 16, p = 0.04), while cTp-e and cTp-e/QTc values were similar. Patients with abnormal HRT presented longer cTp-e and higher cTp-e/QTc than those with normal HRT (92 ± 52 vs. 71 ± 16 ms, p = 0.04; 0.244 ± 0.126 vs. 0.187 ± 0.035, p = 0.03), while QTc values were similar. No differences in QT and Tp-e parameters were observed according to disease duration. CONCLUSION: In SLE patients, Holter monitoring revealed QTc prolongation more frequently than standard ECG. Longer QTc values were observed in patients with more advanced disease, while increased cTp-e and cTp-e/QTc were related to cardiac autonomic dysfunction expressed by abnormal HRT.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Lúpus Eritematoso Sistêmico/fisiopatologia , Adulto , Estudos de Casos e Controles , Ecocardiografia , Eletrocardiografia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
8.
Circ Arrhythm Electrophysiol ; 13(7): e008262, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32538133

RESUMO

BACKGROUND: To facilitate ablation of ventricular tachycardia (VT), an automated localization system to identify the site of origin of left ventricular activation in real time using the 12-lead ECG was developed. The objective of this study was to prospectively assess its accuracy. METHODS: The automated site of origin localization system consists of 3 steps: (1) localization of ventricular segment based on population templates, (2) population-based localization within a segment, and (3) patient-specific site localization. Localization error was assessed by the distance between the known reference site and the estimated site. RESULTS: In 19 patients undergoing 21 catheter ablation procedures of scar-related VT, site of origin localization accuracy was estimated using 552 left ventricular endocardial pacing sites pooled together and 25 VT-exit sites identified by contact mapping. For the 25 VT-exit sites, localization error of the population-based localization steps was within 10 mm. Patient-specific site localization achieved accuracy of within 3.5 mm after including up to 11 pacing (training) sites. Using 3 remotes (67.8±17.0 mm from the reference VT-exit site), and then 5 close pacing sites, resulted in localization error of 7.2±4.1 mm for the 25 identified VT-exit sites. In 2 emulated clinical procedure with 2 induced VTs, the site of origin localization system achieved accuracy within 4 mm. CONCLUSIONS: In this prospective validation study, the automated localization system achieved estimated accuracy within 10 mm and could thus provide clinical utility.


Assuntos
Potenciais de Ação , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Taquicardia Ventricular/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo
9.
Tunis Med ; 98(1): 41-48, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32395776

RESUMO

BACKGROUND: Hypertension is the first cause of atrial fibrillation. Its onset is explained by intricate mechanisms such as atrial conduction impairment. AIM: To evaluate atrial conduction by tissue Doppler imaging in hypertensive patients compared to a control group. METHODS: This is a comparative prospective study performed in the cardiology department of the FSI hospital   enrolling 55 patients with hypertension and 55 controls. All of them underwent a complete echocardiocardiography exam with Doppler tissue imaging. We measured intraatrial and interatrial electromechanical delay by Pulsed Tissue Doppler. Statical analysis was conducted using SPSS version 22.0. Comparison of means was made with t student test. RESULTS: Left ventricular mass and septal thikness were more important in the hypertensive group. Mitral A wave was greater in hypertensive group compared to controls (7,1cm/s vs 5,6cm/s; p<0,0001; respectively). Left atrial volume was of 32,7±6,8mL/m² in hypertensives vs 29,5±4,3 mL/m² in controls (p=0,006). Doppler Tissue study showed homogeneous statistically significant elongation of atrial conduction times in hypertensive patients compared to controls: interatrial time (16.8±7.8ms vs 12.4±4,2ms, p<0.0003) and left intraatrial (27.6±8.6ms vs 19.0±4.3ms, p<0.0001) and right intraatrial time (10.8±6.0ms vs 6.6±2.9ms, p<0.0001; respectively for hypertensive and control subjects. There was a significant correlation between measured intraatrial and interatrial electromechanical delays and duration of hypertension, indexed left atrial volume ans indexed left ventricular mass (r 0.27-0.41, p<0.001). CONCLUSION: Atrial conduction time is significantly longer in hypertensive patients. Impairment of atrial conduction may be predictive of atrial fibrillation and should prompt closer surveillance to detect this arrhythmia in these patients.


Assuntos
Ecocardiografia Doppler de Pulso , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Hipertensão/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Feminino , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Hipertensão/complicações , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores de Risco , Ultrassonografia Doppler de Pulso
10.
Rev Port Cardiol (Engl Ed) ; 39(3): 155-160, 2020 Mar.
Artigo em Inglês, Português | MEDLINE | ID: mdl-32307210

RESUMO

OBJECTIVE: Sudden cardiac death (SCD) plays an important part in all-cause mortality in patients infected with human immunodeficiency virus (HIV). The T-peak to T-end (Tp-e) interval, corrected Tp-e (Tp-ec) interval, and Tp-e/QT ratio on the ECG are parameters used to stratify risk for SCD. The objective of this study was to investigate the differences between HIV-infected patients and healthy individuals in terms of Tp-e interval, Tp-ec interval, and Tp-e/QT ratio, as well as other influencing factors. METHODS: Ninety-eight HIV-infected patients and 62 healthy controls were included in this prospective case-control study. Tp-e interval, Tp-ec interval, and Tp-e/QT ratio were measured in all participants. Echocardiographic examination and routine laboratory analysis were performed. In addition, CD4 T-cell count and HIV RNA levels were assessed in HIV-infected patients. RESULTS: All baseline characteristics were comparable in both groups. The median survival of those living with HIV was 20.63 months; 53% of them had controlled viral load, and 74% were receiving antiretroviral therapy. Mean baseline CD4 T-cell count was 409. In HIV-infected patients, the Tp-e interval and Tp-ec interval were prolonged, and the Tp-e/QT ratio was higher (p<0.001, p<0.001 and p=0.021, respectively). In bivariate and partial correlation analyses, there was a negative correlation between CD4 T-cell level and Tp-e interval, Tp-ec interval, and Tp-e/QT ratio. CONCLUSION: Tp-e interval, Tp-ec interval, and Tp-e/QT ratio were greater in HIV-infected patients compared with healthy individuals. HIV-infected patients, particularly those with low baseline CD4 T-cell counts, should be closely monitored due to risk of SCD.


Assuntos
Morte Súbita Cardíaca/etiologia , Eletrocardiografia/estatística & dados numéricos , Infecções por HIV/complicações , Sistema de Condução Cardíaco/fisiopatologia , Adulto , Terapia Antirretroviral de Alta Atividade/estatística & dados numéricos , Contagem de Linfócito CD4/estatística & dados numéricos , Estudos de Casos e Controles , Ecocardiografia/métodos , Eletrocardiografia/métodos , Feminino , HIV/genética , HIV/imunologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/mortalidade , Infecções por HIV/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Análise de Sobrevida , Carga Viral/estatística & dados numéricos
11.
J Mol Cell Cardiol ; 143: 85-95, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32339564

RESUMO

Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a stress-induced ventricular arrhythmia associated with rhythm disturbance and impaired sinoatrial node cell (SANC) automaticity (pauses). Mutations associated with dysfunction of Ca2+-related mechanisms have been shown to be present in CPVT. These dysfunctions include impaired Ca2+ release from the ryanodine receptor (i.e., RyR2R4496C mutation) or binding to calsequestrin 2 (CASQ2). In SANC, Ca2+ signaling directly and indirectly mediates pacemaker function. We address here the following research questions: (i) what coupled-clock mechanisms and pathways mediate pacemaker mutations associated with CPVT in basal and in response to ß-adrenergic stimulation? (ii) Can different mechanisms lead to the same CPVT-related pacemaker pauses? (iii) Can the mutation-induced deteriorations in SANC function be reversed by drug intervention or gene manipulation? We used a numerical model of mice SANC that includes membrane and intracellular mechanisms and their interconnected signaling pathways. In the basal state of RyR2R4496C SANC, the model predicted that the Na+-Ca2+ exchanger current (INCX) and T-type Ca2+ current (ICaT) mediate between changes in Ca2+ signaling and SANC dysfunction. Under ß-adrenergic stimulation, changes in cAMP-PKA signaling and the sodium currents (INa), in addition to INCX and ICaT, mediate between changes in Ca2+ signaling and SANC automaticity pauses. Under basal conditions in Casq2-/-, the same mechanisms drove changes in Ca2+ signaling and subsequent pacemaker dysfunction. However, SANC automaticity pauses in response to ß-AR stimulation were mediated by ICaT and INa. Taken together, distinct mechanisms can lead to CPVT-associated SANC automaticity pauses. In addition, we predict that specifically increasing SANC cAMP-PKA activity by either a pharmacological agent (IBMX, a phosphodiesterase (PDE) inhibitor), gene manipulation (overexpression of adenylyl cyclase 1/8) or direct manipulation of the SERCA phosphorylation target through changes in gene expression, compensate for the impairment in SANC automaticity. These findings suggest new insights for understanding CPVT and its therapeutic approach.


Assuntos
Predisposição Genética para Doença , Sistema de Condução Cardíaco/metabolismo , Sistema de Condução Cardíaco/fisiopatologia , Mutação , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Algoritmos , Alelos , Animais , Cálcio/metabolismo , Sinalização do Cálcio , Calsequestrina , AMP Cíclico/metabolismo , Proteínas Quinases Dependentes de AMP Cíclico/genética , Proteínas Quinases Dependentes de AMP Cíclico/metabolismo , Genótipo , Cadeias de Markov , Camundongos , Camundongos Knockout , Modelos Biológicos , Canal de Liberação de Cálcio do Receptor de Rianodina/genética , Canal de Liberação de Cálcio do Receptor de Rianodina/metabolismo , Retículo Sarcoplasmático/metabolismo
12.
Heart Rhythm ; 17(8): 1371-1380, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32240822

RESUMO

BACKGROUND: The combination of contact force (CF) and local impedance (LI) may improve tissue characterization and lesion prediction during radiofrequency (RF) ablation. OBJECTIVE: The purpose of this study was to evaluate the utility of LI combined with CF in assessing RF ablation efficacy. METHODS: An LI catheter with CF sensing was evaluated in swine (n = 11) and in vitro (n = 14). The relationship between LI and CF in different tissue types was evaluated in vivo. Discrete lesions were created in vitro and in vivo at a range of forces, powers, and durations. Finally, an intercaval line was created in 3 groups at 30 W: 30s, Δ20Ω, and Δ30Ω. In the Δ20Ω and Δ30Ω groups, the user ablated until a 20 or 30 Ω LI drop. In the 30s group, the user was blinded to LI. RESULTS: In vivo, distinction in LI was found between the blood pool and the myocardium (blood pool: 122 ± 7.02 Ω; perpendicular contact: 220 ± 29 Ω; parallel contact: 207 ± 31 Ω). LI drop correlated with lesion depth both in vitro (R = 0.84) and in vivo (R = 0.79), informing sufficient lesion creation (LI drop >20 Ω) and warning of excessive heating (LI drop >65 Ω). When creating an intercaval line, the total RF time was significantly reduced when using LI guidance (6.4 ± 2 minutes in Δ20Ω and 8.1 ± 1 minutes in Δ30Ω) compared with a standard 30-second workflow (18 ± 7 minutes). Acute conduction block was achieved in all Δ30Ω and 30s lines. CONCLUSION: The addition of LI to CF provides feedback on both electrical and mechanical loads. This provides information on tissue type and catheter-tissue coupling; provides feedback on whether volumetric tissue heating is inadequate, sufficient, or excessive; and reduces ablation time.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Animais , Fibrilação Atrial/fisiopatologia , Modelos Animais de Doenças , Impedância Elétrica , Feminino , Masculino , Suínos
13.
J Am Heart Assoc ; 9(3): e015012, 2020 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-32013706

RESUMO

Background Race is an established risk factor for sudden cardiac death (SCD). We sought to determine whether the association of electrophysiological substrate with SCD varies between black and white individuals. Methods and Results Participants from the ARIC (Atherosclerosis Risk in Communities) study with analyzable ECGs (n=14 408; age, 54±6 years; 74% white) were included. Electrophysiological substrate was characterized by ECG metrics. Two competing outcomes were adjudicated: SCD and non-SCD. Interaction of ECG metrics with race was studied in Cox proportional hazards and Fine-Gray competing risk models, adjusted for prevalent cardiovascular disease, risk factors, and incident nonfatal cardiovascular disease. At the baseline visit, adjusted for age, sex, and study center, blacks had larger spatial ventricular gradient magnitude (0.30 mV; 95% CI, 0.25-0.34 mV), sum absolute QRST integral (18.4 mV*ms; 95% CI, 13.7-23.0 mV*ms), and Cornell voltage (0.30 mV; 95% CI, 0.25-0.35 mV) than whites. Over a median follow-up of 24.4 years, SCD incidence was higher in blacks (2.86 per 1000 person-years; 95% CI, 2.50-3.28 per 1000 person-years) than whites (1.37 per 1000 person-years; 95% CI, 1.22-1.53 per 1000 person-years). Blacks with hypertension had the highest rate of SCD: 4.26 (95% CI, 3.66-4.96) per 1000 person-years. Race did not modify an association of ECG variables with SCD, except QRS-T angle. Spatial QRS-T angle was associated with SCD in whites (hazard ratio, 1.38; 95% CI, 1.25-1.53) and hypertension-free blacks (hazard ratio, 1.52; 95% CI, 1.09-2.12), but not in blacks with hypertension (hazard ratio, 1.15; 95% CI, 0.99-1.32) (P-interaction=0.004). Conclusions Race did not modify associations of electrophysiological substrate with SCD and non-SCD. Electrophysiological substrate does not explain racial disparities in SCD rate.


Assuntos
Arritmias Cardíacas/etnologia , Negro ou Afro-Americano , Morte Súbita Cardíaca/etnologia , Disparidades nos Níveis de Saúde , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , População Branca , Potenciais de Ação , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Feminino , Fatores de Risco de Doenças Cardíacas , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Fatores Raciais , Medição de Risco , Estados Unidos/epidemiologia
14.
Circ Arrhythm Electrophysiol ; 13(3): e007700, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32078374

RESUMO

BACKGROUND: It is difficult to noninvasively phenotype atrial fibrillation (AF) in a way that reflects clinical end points such as response to therapy. We set out to map electrical patterns of disorganization and regions of reentrant activity in AF from the body surface using electrocardiographic imaging, calibrated to panoramic intracardiac recordings and referenced to AF termination by ablation. METHODS: Bi-atrial intracardiac electrograms of 47 patients with AF at ablation (30 persistent, 29 male, 63±9 years) were recorded with 64-pole basket catheters and simultaneous 57-lead body surface ECGs. Atrial epicardial electrical activity was reconstructed and organized sites were invasively and noninvasively tracked in 3-dimension using phase singularity. In a subset of 17 patients, sites of AF organization were targeted for ablation. RESULTS: Body surface mapping showed greater AF organization near intracardially detected drivers than elsewhere, both in phase singularity density (2.3±2.1 versus 1.9±1.6; P=0.02) and number of drivers (3.2±2.3 versus 2.7±1.7; P=0.02). Complexity, defined as the number of stable AF reentrant sites, was concordant between noninvasive and invasive methods (r2=0.5; CC=0.71). In the subset receiving targeted ablation, AF complexity showed lower values in those in whom AF terminated than those in whom AF did not terminate (P<0.01). CONCLUSIONS: AF complexity tracked noninvasively correlates well with organized and disorganized regions detected by panoramic intracardiac mapping and correlates with the acute outcome by ablation. This approach may assist in bedside monitoring of therapy or in improving the efficacy of ongoing ablation procedures.


Assuntos
Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
15.
J Cardiovasc Transl Res ; 13(1): 85-96, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31637585

RESUMO

There are significant differences in clinical presentation and treatment of atrial fibrillation (AF) between women and men. The primary goal of AF management is to restore sinus rhythm and to prevent various complications, including stroke and heart failure. In many areas of AF, such as prevalence, clinical manifestations, morbidity, risk factors, pathophysiology, treatment strategies, and complications, gender-specific variability is observed and needs to be further addressed by large-scale population researches or randomized clinical trials, which help to promote the customization of AF treatment programs, hence to maximize the success rate of AF therapy in both sexes. This review highlights our current understanding of these gender differences in AF and how these differences affect treatment decisions on AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Disparidades nos Níveis de Saúde , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Potenciais de Ação , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Comorbidade , Feminino , Disparidades em Assistência à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Fatores de Risco , Fatores Sexuais
16.
BMC Cardiovasc Disord ; 19(1): 285, 2019 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-31815614

RESUMO

BACKGROUND: Complete and simplified Selvester QRS score have been proposed as valuable clinical tool for estimating myocardial damage in patients with ST-elevation myocardial infarction (STEMI). We sought to comprehensively compare both scoring systems for the prediction of myocardial and microvascular injury assessed by cardiac magnetic resonance (CMR) imaging in patients with acute STEMI. METHODS: In this prospective observational study, 201 revascularized STEMI patients were included. Electrocardiography was conducted at a median of 2 (interquartile range 1-4) days after the index event to evaluate the complete and simplified QRS scores. CMR was performed within 1 week and 4 months thereafter to determine acute and chronic infarct size (IS) as well as microvascular obstruction (MVO). RESULTS: Complete and simplified QRS score showed comparable predictive value for acute (area under the curve (AUC) = 0.64 vs. 0.67) and chronic IS (AUC = 0.63 vs. 0.68) as well as for MVO (AUC = 0.64 vs. 0.66). Peak high sensitivity cardiac troponin T (hs-cTnT) showed an AUC of 0.88 for acute IS and 0.91 for chronic IS, respectively. For the prediction of MVO, peak hs-cTnT represented an AUC of 0.81. CONCLUSIONS: In reperfused STEMI, complete and simplified QRS score displayed comparable value for the prediction of acute and chronic myocardial as well as microvascular damage. However, both QRS scoring systems provided inferior predictive validity, compared to peak hs-cTnT, the clinical reference method for IS estimation.


Assuntos
Potenciais de Ação , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Idoso , Biomarcadores/sangue , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Troponina T/sangue
17.
J Cardiovasc Electrophysiol ; 30(12): 2907-2913, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31579959

RESUMO

INTRODUCTION: Long QT syndrome (LQTS) mutation carriers have elevated the risk of cardiac events even in the absence of QTc prolongation; however, mutation penetrance in patients with normal QTc may be reflected in abnormal T-wave shape, particularly in KCNH2 mutation carriers. We aimed to assess whether the magnitude of a three-dimensional T-wave vector (TwVM) will identify KCNH2-mutation carriers with normal QTc at risk for cardiac events. METHODS: Adult LQT2 patients with QTc < 460 ms in men and <470 ms in women (n = 113, age 42 ± 16 years, 43% male) were compared with genotype-negative family members (n = 1007). The TwVM was calculated using T-wave amplitudes in leads V6, II, and V2 as the square root of (TV62 + TII2 + (0.5*TV2)2 ). Cox regression analysis adjusted for gender and time-dependent beta-blocker use was performed to assess cardiac event (CE) risk, defined as syncope, aborted cardiac arrest, implantable cardioverter-defibrillator therapy, or sudden death. RESULTS: Dichotomized by median of 0.30 mV, lower TwVM was associated with elevated CE risk compared to those with high TwVM (HR = 2.95, 95% CI, 1.25-6.98, P = .014) and also remained significant after including sex and time-dependent beta-blocker usage in the Cox regression analysis (HR = 2.64, 95% CI, 1.64-4.24, P < .001). However, these associations were found only in women but not in men who had low event rates. CONCLUSION: T-wave morphology quantified as repolarization vector magnitude using T-wave amplitudes retrieved from standard 12-lead electrocardiogram predicts cardiac events risk in LQT2 women and appears useful for risk stratification of KCNH2-mutation carriers without QTc prolongation.


Assuntos
Potenciais de Ação , Canal de Potássio ERG1/genética , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/genética , Mutação , Vetorcardiografia , Adulto , Estudos de Casos e Controles , Canal de Potássio ERG1/metabolismo , Feminino , Predisposição Genética para Doença , Humanos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/terapia , Masculino , Pessoa de Meia-Idade , Fenótipo , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo
18.
JCI Insight ; 4(20)2019 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-31619590

RESUMO

Deterioration or inborn malformations of the cardiac conduction system (CCS) interfere with proper impulse propagation in the heart and may lead to sudden cardiac death or heart failure. Patients afflicted with arrhythmia depend on antiarrhythmic medication or invasive therapy, such as pacemaker implantation. An ideal way to treat these patients would be CCS tissue restoration. This, however, requires precise knowledge regarding the molecular mechanisms underlying CCS development. Here, we aimed to identify regulators of CCS development. We performed a compound screen in zebrafish embryos and identified tolterodine, a muscarinic receptor antagonist, as a modifier of CCS development. Tolterodine provoked a lower heart rate, pericardiac edema, and arrhythmia. Blockade of muscarinic M3, but not M2, receptors induced transcriptional changes leading to amplification of sinoatrial cells and loss of atrioventricular identity. Transcriptome data from an engineered human heart muscle model provided additional evidence for the contribution of muscarinic M3 receptors during cardiac progenitor specification and differentiation. Taken together, we found that muscarinic M3 receptors control the CCS already before the heart becomes innervated. Our data indicate that muscarinic receptors maintain a delicate balance between the developing sinoatrial node and the atrioventricular canal, which is probably required to prevent the development of arrhythmia.


Assuntos
Arritmias Cardíacas/tratamento farmacológico , Sistema de Condução Cardíaco/embriologia , Antagonistas Muscarínicos/farmacologia , Organogênese/efeitos dos fármacos , Receptor Muscarínico M3/metabolismo , Tartarato de Tolterodina/farmacologia , Animais , Arritmias Cardíacas/fisiopatologia , Modelos Animais de Doenças , Embrião de Mamíferos , Embrião não Mamífero , Células HEK293 , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Camundongos , Camundongos Knockout , Antagonistas Muscarínicos/uso terapêutico , Miócitos Cardíacos , Receptor Muscarínico M3/genética , Tartarato de Tolterodina/uso terapêutico , Xenopus laevis , Peixe-Zebra
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA