RESUMO
A new method to determine metsulfuron methyl (MSM) and chlorsulfuron (CS) in different water samples was developed. It consists in a solid phase extraction (SPE) procedure using multiwalled carbon nanotubes (MWCNTs) as sorbent material in combination with capillary zone electrophoretic determination. To carry out the pre-concentration step, a simple flow injection system was developed and optimized. Thus, 250 µL of aqueous solution containing methanol 50% (v/v) and acetonitrile 2% (v/v) as eluent, 10 mL of sample and a flow rate of 1.15 mL min(-1) were selected. The CE variables also were optimized. A rapid determination and good resolution of two herbicides were obtained within 9 min using a simple electrophoretic buffer (50 mmol L(-1) sodium tetraborate with 3% of methanol, pH=9.0). Under the optimum conditions, the calibration curves were linear between 0.5 and 6 µg L(-1) for MSM and CS with R(2)=0.995 and 0.997, respectively. The repeatability of the proposed method, expressed as relative standard deviation (RSD), varied between 4.1% and 5.4% (n=10) and the detection limits for MSM and CS were 0.40 and 0.36 µg L(-1), respectively. Good results were achieved when the proposed method was applied to spiked real water samples. The recoveries percentages of the two analytes were over the range 86-108%.
Assuntos
Sulfonatos de Arila/isolamento & purificação , Eletroforese Capilar/métodos , Herbicidas/isolamento & purificação , Extração em Fase Sólida/métodos , Sulfonamidas/isolamento & purificação , Triazinas/isolamento & purificação , Água/análise , Sulfonatos de Arila/análise , Eletroforese Capilar/economia , Herbicidas/análise , Limite de Detecção , Nanotubos de Carbono/química , Extração em Fase Sólida/economia , Sulfonamidas/análise , Triazinas/análise , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificaçãoRESUMO
A reversed-phase high performance liquid chromatographic (RP-HPLC) method for evaluation of purity of tamsulosin in bulk drugs and pharmaceuticals was developed. The separation was accomplished on an Inertsil C(18) column using 10 mM ammonium acetate: acetonitrile as a mobile phase in a gradient elution mode. A photodiode array detector set at 280 nm was used for detection. The impurities were identified by ESI-MS-MS. The detection limits were 0.06-0.11 microg/ml. The method was validated with respect to accuracy, precision, linearity, ruggedness and limits of detection and quantification. It finds application not only for monitoring the reactions during the process development but also on quality assurance of tamsulosin.