Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 447
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Surgery ; 175(5): 1299-1304, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38433078

RESUMO

BACKGROUND: Preoperative imaging before parathyroidectomy can localize adenomas and reduce unnecessary bilateral neck explorations. We hypothesized that (1) the utility of preoperative imaging varies substantially depending on the preoperative probability of having adenoma(s) and (2) that a selective imaging approach based on this probability could avoid unnecessary patient costs and radiation. METHODS: We analyzed 3,577 patients who underwent parathyroidectomy for primary hyperparathyroidism from 2001 to 2022. The predicted probability of patients having single or double adenoma versus hyperplasia was estimated using logistic regression. We then estimated the relationship between the predicted probability of single/double adenoma and the likelihood that sestamibi or 4-dimensional computed tomography was helpful for operative planning. Current Medicare costs and published data on radiation dosing were used to calculate costs and radiation exposure from non-helpful imaging. RESULTS: The mean age was 62 ± 13 years; 78% were women. Adenomas were associated with higher mean calcium (11.2 ± 0.74 mg/dL) and parathyroid hormone levels (140.6 ± 94 pg/mL) than hyperplasia (9.8 ± 0.52 mg/dL and 81.4 ± 66 pg/mL). The probability that imaging helped with operative planning increased from 12% to 65%, as the predicted probability of adenoma increased from 30% to 90%. For every 10,000 patients, a selective approach to imaging that considered the preoperative probability of having adenomas could save patients up to $3.4 million and >239,000 millisieverts of radiation. CONCLUSION: Rather than imaging all patients with primary hyperparathyroidism, a selective strategy that considers the probability of having adenomas could reduce costs and avoid excess radiation exposure.


Assuntos
Adenoma , Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Estados Unidos , Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Masculino , Paratireoidectomia/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Tecnécio Tc 99m Sestamibi , Hiperplasia/diagnóstico por imagem , Medicare , Compostos Radiofarmacêuticos , Hormônio Paratireóideo , Adenoma/diagnóstico por imagem , Adenoma/cirurgia
2.
J Surg Res ; 296: 547-555, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340488

RESUMO

INTRODUCTION: 2%-10% of patients with primary hyperparathyroidism (PHPT) who undergo parathyroidectomy develop persistent/recurrent disease. The aim of this study was to determine which preoperative localization method is most cost-effective in reoperative PHPT. METHODS: Clinical decision analytic models comparing cost-effectiveness of localizing studies in reoperative PHPT were constructed using TreeAge Pro. Cost and probability assumptions were varied via Probabilistic Sensitivity Analysis (PSA) to test the robustness of the base case models. RESULTS: Base case analysis of model 1 revealed ultrasound (US)-guided fine-needle aspiration with PTH assay as most cost-effective after localizing US. This was confirmed on PSA of model 1. Model 2 showed four-dimensional computed tomography (4D-CT) as most cost-effective after negative US. If not localized by US, on PSA, 4D-CT was the next most cost-effective test. CONCLUSIONS: US-guided FNA with PTH is the most cost-effective confirmatory test after US localization. 4D-CT should be considered as the next best test after negative US.


Assuntos
Hiperparatireoidismo Primário , Humanos , Hiperparatireoidismo Primário/cirurgia , Análise Custo-Benefício , Tecnécio Tc 99m Sestamibi , Paratireoidectomia , Tomografia Computadorizada Quadridimensional/métodos , Glândulas Paratireoides/cirurgia
3.
Circ Cardiovasc Imaging ; 16(6): e015034, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37313753

RESUMO

BACKGROUND: Cardiac allograft vasculopathy (CAV) is an obliterative and diffuse form of vasculopathy and is the most common cause of long-term cardiovascular mortality in heart transplant patients. This study aimed to investigate the diagnostic performance of 99mTc and 201Tl tracers in the assessment of CAV using cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) for myocardial blood flow (MBF) and myocardial flow reserve (MFR) quantification, which was further validated using 13 N-NH3 positron emission tomography (PET). METHODS: Thirty-eight patients with prior heart transplantation who underwent CZT SPECT and 13 N-NH3 PET dynamic scans were included in this study. CZT SPECT with 99mTc-sestamibi was used in the first 19 patients and 201Tl-chloride for the remaining patients. To determine the diagnostic accuracy of angiographically defined moderate-to-severe CAV, the analysis included patients who underwent angiographic examinations within 1 year of their second scan. RESULTS: There were no significant differences in the patient characteristics between the 201Tl and 99mTc tracer groups. Both 201Tl and 99mTc CZT SPECT-derived stress MBF and MFR values globally and in 3 coronary territories showed good correlations with 13 N-NH3 PET. The 201Tl and 99mTc cohorts did not differ significantly in the correlation coefficients of CZT SPECT versus PET for MBF and MFR, except for stress MBF (201Tl:0.95 versus 99mTc:0.80, P=0.03). 201Tl and 99mTc CZT SPECT were satisfactory for detecting PET MFR <2.0 (201Tl area under the curve, 0.92 [0.71-0.99], 99mTc area under the curve, 0.87 [0.64-0.97]) and angiographically defined moderate-to-severe CAV, and CZT SPECT results were comparable to that of 13 N-NH3 PET (CZT area under the curve, 0.90 [0.70-0.99], PET area under the curve, 0.86 [0.64-0.97]). CONCLUSIONS: This small study suggests that CZT SPECT using 201Tl and 99mTc tracers showed comparable MBF and MFR, and the results correlated well with those of 13 N-NH3 PET. Hence, CZT SPECT with 201Tl or 99mTc tracers can be used to detect moderate-to-severe CAV in patients with prior heart transplantation. However, validation using larger studies is warranted.


Assuntos
Doença da Artéria Coronariana , Transplante de Coração , Imagem de Perfusão do Miocárdio , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia por Emissão de Pósitrons/métodos , Cádmio , Tecnécio Tc 99m Sestamibi , Transplante de Coração/efeitos adversos , Imagem de Perfusão do Miocárdio/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
5.
Tomography ; 9(1): 264-273, 2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36828373

RESUMO

OBJECTIVE: This study aims to establish a local diagnostic reference level (LDRL) for single-photon emission tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) with respect to myocardial perfusion imaging (MPI). MATERIALS AND METHODS: The acquisition protocol and dosimetry data on the MPI procedures of five SPECT/CT scans and one PET/CT scan were collected. Data on technitum-99m sestamibi (99mTc-sestamibi), 99mTc-tetrofosmin, thallium-201 (201Tl), and rubidium-82 (82RB) were all collected from one centre via questionnaire booklets. Descriptive data analysis was used to analyse all variables, and the 50th percentile was used to analyse each radiation dose quantity. RESULTS: The reported 50th percentile dose for a one-day stress/rest protocol using 99mTc-sestamibi (445/1147 MBq) and 99mTc-tetrofosmin (445/1147 MBq) and for a two-day stress/rest protocol using 99mTc-sestamibi (1165/1184 MBq) and 99mTc-tetrofosmin (1221/1184 MBq) are in good agreement with reported national diagnostic reference levels (NDRLs). However, the dose from the study data on a one-day stress/rest protocol using 99mTc-sestamibi was more than the 50th percentile dose from the Brazilian data (370/1110 MBq) on a similar protocol, and the dose from the study data on a two-day stress/rest protocol using 99mTc-tetrofosmin was more than the 50th percentile dose (1084/1110 MBq) from the United States data on MPI scans. Regarding the computed tomography (CT) portion of the SPECT/CT framework, the 50th percentile doses were lower than all the identified doses in the data considered in the literature reviewed. However, regarding the CT component of the PET/CT MPI scans, the 82RB dose was more than the recorded doses in the CT data in the published literature. CONCLUSION: This study determined the LDRL of five SPECT/CT protocols and one PET/CT MPI protocol. The results suggest that there may be opportunities to optimise the patient radiation burden from administered activities in patients undergoing SPECT examinations and the CT components associated with 82RB PET/CT scans without compromising diagnostic image quality.


Assuntos
Compostos de Organotecnécio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Estados Unidos , Tecnécio Tc 99m Sestamibi , Doses de Radiação , Perfusão
6.
Med Phys ; 50(5): 3019-3026, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36617729

RESUMO

BACKGROUND: Although diabetic and atherosclerotic vascular diseases have different pathophysiological mechanisms, the screening methods currently used for diabetic lower-extremity vascular diseases are mainly based on the evaluation methods used for atherosclerotic vascular diseases. Thus, assessment of microvascular perfusion is of great importance in early detection of lower-extremity ischemia in diabetes. PURPOSE: This cross-sectional study aimed to develop a quantitative model for evaluating lower-extremity perfusion. METHODS: We recruited 57 participants (14 healthy participants and 43 diabetes patients, of which 16 had lower-extremity arterial disease [LEAD]). All participants underwent technetium-99 m sestamibi (99mTc-MIBI) scintigraphy and ankle-brachial index (ABI) examination. We derived two key perfusion kinetics indices named activity perfusion index (API) and basal perfusion index (BPI). This study was registered in ClinicalTrials.gov (URL: https://www. CLINICALTRIALS: gov, NCT02752100). RESULTS: The estimated limb perfusion values in our lower-extremity perfusion assessment (LEPA) model showed excellent consistency with the actual measured data. Diabetes patients showed reduced lower-extremity perfusion in comparison with the control group (BPI: 106.21 ± 11.99 vs. 141.56 ± 17.38, p < 0.05; API: 12.34 ± 3.27 vs. 14.56 ± 3.12, p < 0.05). Using our model, the reductions in lower-extremity perfusion could be detected early in approximately 96.30% of diabetes patients. Patients with LEAD showed more severe reductions in lower-extremity perfusion than diabetes patients without LEAD (BPI: 47.85 ± 20.30 vs. 106.21 ± 11.99, p < 0.05; API: 7.06 ± 1.70 vs. 12.34 ± 3.27, p < 0.05). Discriminant analysis using API and BPI could successfully screen all diabetes patients with LEAD with a sensitivity of 100% and specificity of 80.77%. CONCLUSIONS: We established a LEPA model that could successfully assess lower-extremity microvascular perfusion in diabetes patients. This model has important application value for the recognition of early-stage LEAD in patients with diabetes.


Assuntos
Diabetes Mellitus , Angiopatias Diabéticas , Doença Arterial Periférica , Humanos , Estudos Transversais , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Angiopatias Diabéticas/diagnóstico , Tecnécio Tc 99m Sestamibi , Perfusão , Diabetes Mellitus/diagnóstico por imagem
7.
Med Phys ; 50(5): 2985-2997, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36583691

RESUMO

BACKGROUND: Molecular breast imaging (MBI) of 99m Tc-sestamibi is an emerging adjunct qualitative tool in the detection and diagnosis of breast cancer. PURPOSE: This work outlines the development and performance evaluation of a methodology to absolutely quantify tumor 99m Tc activity uptake using a commercially available dual-headed MBI system by implementing corrections for background, scatter, attenuation, and detector characteristics. METHODS: A validated Monte Carlo application of a commercial MBI system was used to simulate over 7000 unique acquisitions of spherical and ellipsoidal tumors in breast tissue. Tumor absolute activity was calculated following background, scatter, and attenuation corrections of tumor region of interest counts. The methodology was first optimized using a set of high-uptake spherical tumors, and its accuracy and precision was then assessed in a set of spherical tumors with clinical uptake conditions. Finally, the performance of the activity methodology was evaluated under various bias and uncertainty conditions to better characterize the technique under expected clinical measurement conditions. RESULTS: In a test set of images with clinically relevant contrast and noise conditions, the mean ± standard deviation relative error in total tumor activity was 0.5% ± 6.5% (n = 2363) under ideal measurement conditions. Allowing for variability in tumor and background contours and in estimated tumor depths, the expected accuracy of the methodology in clinical practice was 0.5% ± 11.1% (n = 2363), with minimal loss of accuracy for ellipsoidal tumors. CONCLUSIONS: Planar MBI photopeak images acquired with standard-of-care protocols can be used to accurately quantify absolute tumor 99m Tc activity with an accuracy and precision of 0.5% ± 11.1%. The reported precision was based on a comprehensive evaluation of random errors and systematic biases.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Cintilografia , Neoplasias da Mama/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Mamografia , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único
8.
Front Endocrinol (Lausanne) ; 13: 915279, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36157459

RESUMO

Objective: To explore the valuably influential factors and improve the diagnostic accuracy and efficiency of 99mTc-methoxyisobutylisonitrile (MIBI) uptake in parathyroids of secondary hyperparathyroidism (SHPT) patients with chronic renal failure (CRF). Methods: The correlation analysis was performed between clinical indices related to CRF and 99mTc-MIBI uptake intensity TBR (the gray value mean ratio between the parathyroid target and the bilateral neck background, semiquantitatively calculated with ImageJ software). All clinical indices and TBRs were compared by a three- or two-level grouping method of MIBI uptake, which was visually qualitatively assessed. The three-level grouping method comprised slight, medium, and high groups with little, faint, and distinct MIBI concentration in parathyroids, respectively. The two-level grouping method comprised insignificant and significant groups with TBR greater than or less than 0.49-0.71, respectively. Results: MIBI uptake was significantly positively related to patient age, CRF course, hemodialysis vintage, serum parathyroid hormone (PTH), and alkaline phosphatase (AKP) but was significantly negatively related to serum uric acid (UA). MIBI washout was significantly positively related to patient age but was significantly negatively related to serum phosphorus (P) and calcium (Ca) × P. Oral administration of calcitriol and calcium could significantly reduce the MIBI uptake. MIBI uptake tendency might alter. Such seven indices, namely the MIBI uptake, CRF course, hemodialysis vintage, serum AKP, calcium, cysteine proteinase inhibitor C, and PTH, were comparable between the slight and medium groups but were significantly different between the slight and high groups or between the medium and high groups. The above seven indices plus blood urea nitrogen/creatinine were all significantly different between the insignificant and significant groups. All above significances were with P < 0.05. Conclusions: Patient age, CRF course, hemodialysis vintage, serum PTH, AKP, UA, phosphorus, Ca × P, oral administration of calcitriol and calcium, and parathyroids themselves can significantly influence MIBI uptake in parathyroids of SHPT patients with CRF. The two-level grouping method of MIBI intensity should be adopted to qualitatively diagnose the MIBI uptake.


Assuntos
Hiperparatireoidismo Secundário , Falência Renal Crônica , Fosfatase Alcalina , Calcitriol , Cálcio , Creatinina , Inibidores de Cisteína Proteinase , Humanos , Hiperparatireoidismo Secundário/complicações , Hiperparatireoidismo Secundário/diagnóstico por imagem , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Hormônio Paratireóideo , Fósforo , Tecnécio Tc 99m Sestamibi , Ácido Úrico
10.
J Nucl Cardiol ; 29(6): 3341-3351, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35378694

RESUMO

BACKGROUND: In patients with heart failure (HF) sequential imaging studies have demonstrated a relationship between myocardial perfusion and adrenergic innervation. We evaluated the feasibility of a simultaneous low-dose dual-isotope 123I/99mTc-acquisition protocol using a cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) camera. METHODS AND RESULTS: Thirty-six patients with HF underwent simultaneous low-dose 123I-metaiodobenzylguanidine (MIBG)/99mTc-sestamibi gated CZT-SPECT cardiac imaging. Perfusion and innervation total defect sizes and perfusion/innervation mismatch size (defined by 123I-MIBG defect size minus 99mTc-sestamibi defect size) were expressed as percentages of the total left ventricular (LV) surface area. LV ejection fraction (EF) significantly correlated with perfusion defect size (P < .005), innervation defect size (P < .005), and early (P < .05) and late (P < .01) 123I-MIBG heart-to-mediastinum (H/M) ratio. In addition, late H/M ratio was independently associated with reduced LVEF (P < .05). Although there was a significant relationship (P < .001) between perfusion and innervation defect size, innervation defect size was larger than perfusion defect size (P < .001). At multivariable linear regression analysis, 123I-MIBG washout rate (WR) correlated with perfusion/innervation mismatch (P < .05). CONCLUSIONS: In patients with HF, a simultaneous low-dose dual-isotope 123I/99mTc-acquisition protocol is feasible and could have important clinical implications.


Assuntos
Insuficiência Cardíaca , Imagem de Perfusão do Miocárdio , Humanos , 3-Iodobenzilguanidina , Adrenérgicos , Coração/diagnóstico por imagem , Coração/inervação , Insuficiência Cardíaca/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio Tc 99m Sestamibi , Perfusão
11.
Curr Radiopharm ; 15(2): 117-122, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33902427

RESUMO

INTRODUCTION: In myocardial perfusion imaging, reducing the number of photons in images of obese patients causes poor image quality. To solve this problem, we need to inject the tracer according to the patients' weight. Therefore, this study aimed to investigate the relationship between myocardial photon counts with patients' weight, BMI, and gender. MATERIALS AND METHODS: A total of 129 patients underwent myocardial perfusion imaging in a twoday stress-first protocol, but only rest images were included in this study. Multiplication factor was used to determine the amount of radiopharmaceutical activity injected into the patients. For evaluating the effect of gender, the photon counts of 22 female patients were also assessed when the breast tissue was pulled upward (Breast Up). The total myocardial detector counts in the raw images were calculated from the summation of 32 projections. A multiple linear regression test was used to simultaneously examine the effects of weight, BMI, and gender on photon counts. RESULTS: There was no significant relationship between photon counts and patients' weight (p=0.129) and BMI (0.406), but gender had significant effects on photon counts, and myocardial detector counts were found to be higher in males (p=0.00). There was a statistically significant difference between the images of Breast Up and Non-Breast Up, and myocardial detector counts were higher in the Breast Up imaging method (p=0.00). CONCLUSION: Using the bodyweight formula, the image quality was comparable in obese and lean patients, but myocardial detector counts were lower in females, and this formula needs to be adjusted according to the patient's gender.


Assuntos
Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Índice de Massa Corporal , Peso Corporal , Feminino , Humanos , Masculino , Obesidade/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos
12.
Am J Surg ; 223(4): 686-693, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34407918

RESUMO

BACKGROUND: Fluorescence angiography (FA) using indocyanine green dye (ICG) has recently been introduced for real-time identification of parathyroid adenomas. However, time to peak fluorescence has not yet been critically evaluated. METHODS: This was a retrospective review of parathyroidectomies with ICG FA over a one-year period. RESULTS: There were 66 patients with average age of 64 years. The average time to initial fluorescence was 26.7 s and to peak fluorescence was 38.0 s. The time to saline flush administration significantly correlated with times to initial and peak fluorescence (p < .0001). The rate of in-situ fluorescence was 97%. The rates of suspected adenoma detection were 69% for sestamibi scan, 71% for ultrasound, and 96% for CT scan. Imaging was discordant in 13 cases (20%), with the adenoma located on the opposite side of the neck in 4 cases. CONCLUSIONS: ICG FA is a rapid and effective adjunct for the intraoperative identification of parathyroid adenomas.


Assuntos
Adenoma , Neoplasias das Paratireoides , Adenoma/diagnóstico por imagem , Adenoma/cirurgia , Humanos , Verde de Indocianina , Pessoa de Meia-Idade , Imagem Óptica , Glândulas Paratireoides/cirurgia , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia/métodos , Perfusão , Tecnécio Tc 99m Sestamibi
13.
Surgery ; 171(1): 55-62, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340823

RESUMO

BACKGROUND: Primary hyperparathyroidism historically necessitated bilateral neck exploration to remove abnormal parathyroid tissue. Improved localization allows for focused parathyroidectomy with lower complication risks. Recently, positron emission tomography using radiolabeled 18F-fluorocholine demonstrated high accuracy in detecting these lesions, but its cost-effectiveness has not been studied in the United States. METHODS: A decision tree modeled patients who underwent parathyroidectomy for primary hyperparathyroidism using single preoperative localization modalities: (1) positron emission tomography using radiolabeled 18F-fluorocholine, (2) 4-dimensional computed tomography, (3) ultrasound, and (4) sestamibi single photon emission computed tomography (SPECT). All patients underwent either focused parathyroidectomy versus bilateral neck exploration, with associated cost ($) and clinical outcomes measured in quality-adjusted life-years gained. Model parameters were informed by literature review and Medicare costs. Incremental cost-utility ratios were calculated in US dollars/quality-adjusted life-years gained, with a willingness-to-pay threshold set at $100,000/quality-adjusted life-year. One-way, 2-way, and threshold sensitivity analyses were performed. RESULTS: Positron emission tomography using radiolabeled 18F-fluorocholine gained the most quality-adjusted life-years (23.9) and was the costliest ($2,096), with a total treatment cost of $11,245 or $470/quality-adjusted life-year gained. Sestamibi single photon emission computed tomography and ultrasound were dominated strategies. Compared with 4-dimentional computed tomography, the incremental cost-utility ratio for positron emission tomography using radiolabeled 18F-fluorocholine was $91,066/quality-adjusted life-year gained in our base case analysis, which was below the willingness-to-pay threshold. In 1-way sensitivity analysis, the incremental cost-utility ratio was sensitive to test accuracy, positron emission tomography using radiolabeled 18F-fluorocholine price, postoperative complication probabilities, proportion of bilateral neck exploration patients needing overnight hospitalization, and life expectancy. CONCLUSION: Our model elucidates scenarios in which positron emission tomography using radiolabeled 18F-fluorocholine can potentially be a cost-effective imaging option for primary hyperparathyroidism in the United States. Further investigation is needed to determine the maximal cost-effectiveness for positron emission tomography using radiolabeled 18F-fluorocholine in selected populations.


Assuntos
Análise Custo-Benefício/estatística & dados numéricos , Hiperparatireoidismo Primário/diagnóstico , Glândulas Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico , Tomografia por Emissão de Pósitrons/economia , Colina/administração & dosagem , Colina/análogos & derivados , Colina/economia , Radioisótopos de Flúor/administração & dosagem , Radioisótopos de Flúor/economia , Tomografia Computadorizada Quadridimensional/economia , Humanos , Hiperparatireoidismo Primário/economia , Hiperparatireoidismo Primário/etiologia , Hiperparatireoidismo Primário/cirurgia , Medicare/economia , Medicare/estatística & dados numéricos , Modelos Econômicos , Glândulas Paratireoides/patologia , Glândulas Paratireoides/cirurgia , Neoplasias das Paratireoides/complicações , Neoplasias das Paratireoides/economia , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/economia , Tomografia por Emissão de Pósitrons/métodos , Cuidados Pré-Operatórios/economia , Cuidados Pré-Operatórios/métodos , Anos de Vida Ajustados por Qualidade de Vida , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/economia , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi/administração & dosagem , Tecnécio Tc 99m Sestamibi/economia , Ultrassonografia/economia , Estados Unidos
14.
Curr Med Imaging ; 18(4): 404-408, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34749623

RESUMO

BACKGROUND: The therapeutic approaches of differentiated thyroid carcinoma (DTC) are surgery, ablation therapy with the postoperative use of radioiodine-131 (131I), and thyroid-stimulating hormone (TSH) suppression therapy. After the surgical therapy, the patient should be assessed for remnants/metastases. OBJECTIVE: The purpose of this research was to investigate the role of technetium-99m-methoxyisobutylisonitrile (99mTc-MIBI) single photon emission computed tomography/computed tomography (SPECT/CT) in the postoperative management of patients with DTC. METHODS: The study comprised 22 DTC patients (13 women, 9 men; mean age 46.55 ± 13.27 y) who underwent a total thyroidectomy previously. All patients were investigated for thyroid remnants/ metastases by99mTc-MIBI SPECT/CT, posttherapy 131I whole-body scan (WBS) and ultrasound (US). Serum TSH, thyroglobulin and anti-Tg antibody levels were measured. Results of imaging modalities and laboratory measurements were compared with each other. RESULTS: 99mTc-MIBI SPECT/CT, 131I WBS and US respectively demonstrated thyroid remnants in 15 (68.18%), 22 (100%) and 14 (63.63%) of all patients and metastatic lymph nodes in 8 (100%), 6 (75%) and 6 (75%) of the 8 patients with lymph node metastases.99mTc-MIBI SPECT/CT also demonstrated lung metastases in 2 patients (9.09% of all patients). The same result was obtained with 131I WBS. CONCLUSION: The findings of this study show that 99mTc-MIBI SPECT/CT can be effective for detecting metastases in patients with DTC who underwent surgery prior to 131I therapy.


Assuntos
Tecnécio Tc 99m Sestamibi , Neoplasias da Glândula Tireoide , Adulto , Feminino , Humanos , Radioisótopos do Iodo/uso terapêutico , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/cirurgia , Tireotropina , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
15.
Cir Pediatr ; 34(2): 63-66, 2021 Apr 01.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33826257

RESUMO

OBJECTIVE: To determine whether combined ultrasonography and parathyroid scintigraphy improves hyperplastic parathyroid gland detection in the pediatric population for parathyroidectomy planning in patients with secondary or tertiary hyperparathyroidism. MATERIAL AND METHODS: An observational and analytical retrospective cohort study was carried out. Patients diagnosed with secondary or tertiary hyperparathyroidism from 2011 to 2018 undergoing total or subtotal parathyroidectomy were included - provided there was information available on pathological examination and surgical protocol. RESULTS: N = 15 patients. A total of 53 parathyroid glands diagnosed with hyperplasia using either of the imaging methods were analyzed. For each method (ultrasonography and scintigraphy) and the combination of both, sensitivity and area under the curve were calculated, using pathological examination result as a reference. Ultrasonography and scintigraphy diagnostic match was 66%. DISCUSSION AND CONCLUSIONS: The intraoperative difficulty of parathyroid gland identification as well as the anatomical variation that these present is well-known. Ultrasonography detected more glands than scintigraphy when diagnosing parathyroid hyperplasia. The combination of both methods allows patients with a first negative study to be detected.


OBJETIVO: Determinar si la combinación de la ecografía y la gammagrafia paratiroidea mejora la capacidad de detección de glándulas paratiroideas hiperplásicas en población pediátrica para la planificación de paratiroidectomía en pacientes con hiperparatiroidismo secundario o terciario. MATERIAL Y METODOS: Estudio observacional y analítico de una cohorte retrospectiva. Se incluyeron pacientes con hiperparatiroidismo secundario o terciario, entre 2011 y 2018, que fueron operados de paratiroidectomía total o subtotal, en los que haya podido recabarse información de la anatomía patológica y protocolo quirúrgico. RESULTADOS: N = 15 pacientes. Se analizaron un total de 53 glándulas paratiroides con diagnóstico de hiperplasia en alguno de los métodos por imágenes evaluados. Para cada método (ecografía y gammagrafía) y para la combinación de ambos, se obtuvieron la sensibilidad y área bajo la curva, tomando como referencia el resultado obtenido por anatomía patológica. La concordancia en el diagnóstico de la ecografía y de la gammagrafía fue del 66%. DISCUSION Y CONCLUSIONES: Es bien conocida la dificultad intraquirúrgica que se plantea en cuanto a la localización de las glándulas paratiroides así como la variación anatómica que estas presentan. La ecografía detectó más glándulas que la gammagrafía en el diagnóstico de hiperplasia paratiroidea. La combinación de ambos métodos permite detectar a aquellos pacientes en los cuales un primer estudio resultó negativo.


Assuntos
Hiperparatireoidismo , Tecnécio Tc 99m Sestamibi , Criança , Humanos , Hiperparatireoidismo/diagnóstico por imagem , Cintilografia , Estudos Retrospectivos , Ultrassonografia
16.
J Nucl Med ; 62(9): 1285-1291, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33452040

RESUMO

Hyperparathyroidism is an endocrine disorder caused by one or more hyperfunctioning parathyroid glands. Current imaging consisting of ultrasound and 99mTc-sestamibi is imprecise, making localization difficult. 18F-fluorocholine (18F-FCH) PET has recently shown promise in presurgical localization of parathyroid adenomas. The primary aim of this study was to summarize the sensitivities and specificities of studies using 18F-FCH PET to localize hyperparathyroidism. A secondary aim was to summarize a subset of studies in which 99mTc-sestamibi scans were also used and to compare the performance of the 2 modalities. Methods: We searched the MEDLINE and EMBASE databases following the PRISMA (Preferred Reporting Items for Systematic Review and Metaanalysis) statement. Quality was assessed using the QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies). Twenty studies were included for quantitative assessment in our metaanalysis. A random-effects model and a hierarchic summary receiver-operating-characteristic model was used to summarize the sensitivity of 18F-FCH PET in detecting abnormal parathyroid adenomas. We used the same methodology to assess sensitivity of 99mTc-sestamibi, as a comparison to 18F-FCH PET. Results:18F-FCH PET had a high sensitivity, 0.97 (range, 0.96-0.98), for the detection of abnormal parathyroid adenomas. In the subpopulation for which both 18F-FCH and 99mTc-sestamibi were reported, 18F-FCH also had a higher sensitivity, 0.96 (0.94-0.98), than the 0.54 (0.29-0.79) reported for 99mTc-sestamibi (P < 0.001). Conclusion:18F-FCH PET demonstrates high localization accuracy in patients with hyperparathyroidism. This metaanalysis supports the use of 18F-FCH over 99mTc-sestamibi in patients with hyperparathyroidism.


Assuntos
Neoplasias das Paratireoides , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Glândulas Paratireoides , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tecnécio Tc 99m Sestamibi
17.
Curr Radiopharm ; 14(2): 161-169, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32693772

RESUMO

BACKGROUND: Radioguided surgery represents a validated technique for the detection and the excision of abnormal parathyroid glands responsible for primary hyperparathyroidism (PHPT). To date little attention has been paid as to how the characteristics of gamma-probes can influence surgical procedure and time, thus having an impact on postoperative morbidity, hospitalization and costs. METHODS: We designed a new prototype of gamma-probe, the Gonioprobe, and tested its clinical utility in the operating room. Gonioprobe, thanks to its 5 scintillating independent crystals, performs the dual function of Navigator and Lock-on-target. These characteristics allow the immediate guidance of the surgeon's hand towards the source with very high precision, and with a much higher spatial resolution than commercial probes. Gonioprobe was used during intervention to detect abnormal parathyroid tissue, and to ensure no radioactivity in surgery bed after adenoma removal. RESULTS: We tested our gamma-probe on parathyroid adenomas particularly difficult to identify at a visual inspection due to anatomy modifications from previous neck surgery and/or characterized by uncommon localization. Moreover, parathyroid adenomas were hardly removable due to the proximity to the esophagus, neck vessels and/or recurrent laryngeal nerve (RLN). An intraoperative nerve monitoring system was used to protect the recurrent laryngeal nerve from injuries. Parathyroid hormone (PTH) assay and frozen biopsy confirmed the successful excision of the adenomas. CONCLUSION: The intraoperative use of the innovative Gonioprobe along with the nerve monitoring system allowed an accurate and safe removal of parathyroid adenomas and offered a significant advantage by reducing surgical time and postoperative complications, as well as hospitalization and costs.


Assuntos
Hiperparatireoidismo Primário/cirurgia , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Biópsia , Custos e Análise de Custo , Feminino , Câmaras gama , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias , Cintilografia , Compostos Radiofarmacêuticos , Traumatismos do Nervo Laríngeo Recorrente/prevenção & controle , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único
18.
Eur Urol Focus ; 7(4): 827-834, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32115400

RESUMO

BACKGROUND: Incidentally detected small renal masses (SRMs) may be one of several benign or malignant tumor histologies, and are heterogeneous in oncologic potential. Renal mass biopsy can be used to determine the histology of SRMs. However, this invasive approach has significant limitations. Technetium-99m sestamibi single photon emission computed tomography/computed tomography (99mTc-sestamibi SPECT/CT) is a promising imaging tool that can aid in identifying benign renal oncocytomas and hybrid oncocytic/chromophobe tumors. OBJECTIVE: To evaluate the clinical and economic value of 99mTc-sestamibi SPECT/CT in guiding the management of SRMs. DESIGN, SETTING, AND PARTICIPANTS: We developed a decision analysis model to estimate the costs and health outcomes of competing management strategies for a healthy 65-yr-old patient with an asymptomatic SRM. INTERVENTION: Empiric surgery (reference); real-world clinical practice (RWCP) consisting of empiric surgery, thermal ablation, and active surveillance (alternative reference); renal mass biopsy (option 1); 99mTc-sestamibi SPECT/CT (option 2); and 99mTc-sestamibi SPECT/CT followed by biopsy to confirm benign SRMs (option 3). OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: We assessed lifetime health utilities, measured in quality-adjusted life years (QALYs), and direct medical costs from a health payer perspective. We calculated the incremental cost-effectiveness ratio (ICER) for options 1-3 versus the reference and alternative reference arms, with a willingness-to-pay threshold of $50 000/QALY. Univariate, multivariate, and probabilistic sensitivity analyses were performed. RESULTS AND LIMITATIONS: Option 3 had a very low risk of untreated malignant tumors (0.2%, vs 2.1% for option 1, 4.2% for option 2, and 0% for empiric surgery) and the highest probability of leaving benign tumors untreated (84.4%, vs 53.9% for option 1, 51.7% for option 2, and 0% for empiric surgery). Option 3 dominated empiric surgery and options 1 and 2 (ie, lower costs and higher QALYs). Compared with RWCP, options 1-3 were all cost effective; option 3 had the lowest ICER of $18 821/QALY. These findings were robust to alternative input values. Study limitations included data uncertainties and a limited number of centers from which 99mTc-sestamibi SPECT/CT performance data were collected. CONCLUSIONS: 99mTc-sestamibi SPECT/CT followed by confirmatory biopsy helps avoid surgery for benign SRMs, minimizes untreated malignant SRMs, and is cost effective compared with existing strategies. PATIENT SUMMARY: Our research suggests that by using a noninvasive imaging test, known as technetium-99m sestamibi single photon emission computed tomography/computed tomography, to diagnose small renal masses, urologists may avoid unnecessary surgery for benign tumors and minimize the risk of leaving a malignant tumor untreated. Moreover, the use of this strategy to diagnose small renal masses is cost effective for the health care system.


Assuntos
Neoplasias Renais , Tecnécio , Análise Custo-Benefício , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X
19.
J Nucl Med Technol ; 48(4): 372-377, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32887761

RESUMO

Imaging of dextrocardia in humans requires an understanding of the orientation of the heart chambers and walls. There are many types of cardiac malpositioning, such as dextrocardia (with or without situs inversus), mesocardia, and levocardia. Myocardial perfusion scintigraphy of dextrocardia has been explained in case reports and imaging atlases; however, myocardial viability assessment using nuclear medicine imaging techniques is less documented in the literature. Methods: In 2 cases of dextrocardia with situs inversus and 1 case of mesocardia, myocardial viability was assessed using 99mTc-sestamibi rest perfusion scintigraphy and 18F-FDG PET. Cardiac SPECT images of dextrocardia with situs inversus were acquired using the feet-first supine position with a 180° arc from left anterior oblique to right posterior oblique, whereas a right-lateral-to-left-lateral arc was used for mesocardia. The processing and reconstruction were done by entering the dataset for the feet-first supine position and repeating after entering the dataset for the feet-first prone position. The 2 sets of reconstructed images were compared for orientation of walls and cardiac chambers. Results: The first processing, using the feet-first supine position, revealed an interchanged septum and lateral wall in reconstructed images of dextrocardia with situs inversus. This interchange was corrected by changing the position to prone during processing of the rest perfusion and PET raw data. The display of cardiac slices in various axes matched the conventional nomenclature for the septum and lateral wall, leading to easy interpretation. However, this change was not required in the mesocardia, for which the location of the heart chambers was not interchanged. Conclusion: Because the acquisition protocol for SPECT is a semicircular orbit, the various types of dextrocardia require careful selection of the arc, with the patient positioning kept feet-first supine. Processing and reconstruction of data by changing the patient position to prone was found to be most useful method of matching the septum and lateral wall orientation for interpretation of images.


Assuntos
Dextrocardia , Miocárdio/citologia , Medicina Nuclear , Tomografia por Emissão de Pósitrons , Sobrevivência de Tecidos , Tomografia Computadorizada de Emissão de Fóton Único , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tecnécio Tc 99m Sestamibi
20.
Urol Oncol ; 38(12): 937.e11-937.e17, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32859460

RESUMO

INTRODUCTION: Despite the increasing accuracy of imaging modalities, the rate of benign renal tumors misclassified as malignant before surgery still non-negligible. Tc-99m sestamibi was demonstrated to be a possible reliable agent in discriminating oncocytoma from renal cell carcinoma (RCC). We aimed to study the efficacy of Tc-99m MIBI tumor scintigraphy in evaluating clinical T1 renal masses. METHODS AND MATERIALS: Between July 2017 and March 2019, patients with clinical T1 renal mass underwent preoperative Tc-99m sestamibi tumor scintigraphy. Tc-99m sestamibi tumor scintigraphy findings were correlated with the postoperative pathology results. RESULTS: A total of 90 renal masses were included in the study. Male to female ratio was 67/23. The mean age and tumor size were 55.5 ± 11.4 years and 4 ± 1.4 cm, respectively. In pathological evaluation, 20% (18/90) of masses were reported as benign (10 oncocytomas, 4 angiomyolipomas (AML), 2 chronic sclerosis, 1 fibroma and 1 hydatid cyst). While Tc-99m sestamibi uptake was positive in all oncocytomas; 6 patients with chronic sclerosis, fibroma, hydatid cyst and angiomyolipoma pathologies had no uptake. Except for 5 chromophobe cell RCC and 3 oncocytic papillary RCC masses, malignant lesions had no uptake. In predicting benign pathology, Tc-99m sestamibi tumor scintigraphy had positive and negative predictive value of 60% and 91.3%, respectively. The mean Tc-99m 2-methoxy isobutyl isonitrile lesion/normal renal parenchyma ratio of benign and malignant lesions was 0.6 and 0.37, respectively. A relative uptake of 0.49 was an acceptable cutoff point to discriminate oncocytomas from all other pathologies. CONCLUSION: Tc-99m sestamibi tumor scintigraphy has a beneficial role in the assessment of clinical T1 renal mass. Masses with negative uptake harbor high probability of being malignant. While evaluating masses with positive uptake, it should be kept in mind that some malignant pathologies may demonstrate similar results.


Assuntos
Adenoma Oxífilo/diagnóstico por imagem , Carcinoma de Células Renais/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Adenoma Oxífilo/patologia , Adulto , Idoso , Carcinoma de Células Renais/patologia , Feminino , Humanos , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA