1.
Int J Radiat Biol ; 100(2): 183-189, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37747407

RESUMO

INTRODUCTION: Radiation-induced secondary cancers relevant to proton therapy are still a main concern among cancer survivors. This study aims to determine the effects of age at exposure and treatment field size on radiation-induced secondary tumors following the proton therapy of lung cancer within out of field organs through the Monte Carlo (MC) simulation approach. MATERIAL AND METHODS: A full MC model of ICRP-110 male phantom was simulated to calculate the absorbed dose corresponding to secondary radiations within distant organs from the tumor volume. Then, the risks of secondary malignancies were estimated by employing the recommended risk model by the Committee of Biological Effects of Ionizing Radiation (BEIR) for different treatment field sizes and various patient ages at exposure. RESULTS: The results revealed that by increasing the patient age from 25 to 45 years, lifetime attributable risk (LAR) values were decreased. Maximum and minimum mortality rates were obtained for the liver and thyroid at the fixed age of 25 years, respectively. Calculated risk values for most near organs to the tumor were higher than those for distant organs. Changing the aperture size from 5 × 5 cm2 to 8 × 10 cm2 resulted in LAR increments with maximum variations of 12.5% for the stomach and a rough variation of 1.12 times in LAR for all exposure ages. CONCLUSION: Our work on whole-body phantom addresses the impact of age at exposure and aperture size on LAR during the proton therapy of lung cancer. To minimize secondary cancer risks relevant to proton therapy of lung cancer, extra attention should be considered.


Assuntos
Neoplasias Pulmonares , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária , Terapia com Prótons , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Terapia com Prótons/efeitos adversos , Neoplasias Pulmonares/radioterapia , Medição de Risco , Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Método de Monte Carlo , Dosagem Radioterapêutica
2.
Phys Med Biol ; 68(24)2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37549670

RESUMO

Objective. Non-primary radiation doses to normal tissues from proton therapy may be associated with an increased risk of secondary malignancies, particularly in long-term survivors. Thus, a systematic method to evaluate if the dose level of non-primary radiation meets the IEC standard requirements is needed.Approach. Different from the traditional photon radiation therapy system, proton therapy systems are composed of several subsystems in a thick bunker. These subsystems are all possible sources of non-primary radiation threatening the patient. As a case study, 7 sources in the P-Cure synchrotron-based proton therapy system are modeled in Monte Carlo (MC) code: tandem injector, injection, synchrotron ring, extraction, beam transport line, scanning nozzle and concrete reflection/scattering. To accurately evaluate the synchrotron beam loss and non-primary dose, a new model called the torus source model is developed. Its parametric equations define the position and direction of the off-orbit particle bombardment on the torus pipe shell in the Cartesian coordinate system. Non-primary doses are finally calculated by several FLUKA simulations.Main results. The ratios of summarized non-primary doses from different sources to the planned dose of 2 Gy are all much smaller than the IEC requirements in both the 15-50 cm and 50-200 cm regions. Thus, the P-Cure synchrotron-based proton therapy system is clean and patient-friendly, and there is no need an inner shielding concrete between the accelerator and patient.Significance. Non-primary radiation dose level is a very important indicator to evaluate the quality of a PT system. This manuscript provides a feasible MC procedure for synchrotron-based proton therapy with new beam loss model. Which could help people figure out precisely whether this level complies with the IEC standard before the system put into clinical treatment. What' more, the torus source model could be widely used for bending magnets in gantries and synchrotrons to evaluate non-primary doses or other radiation doses.


Assuntos
Terapia com Prótons , Humanos , Doses de Radiação , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Síncrotrons , Método de Monte Carlo , Dosagem Radioterapêutica
3.
Cancer Radiother ; 27(4): 319-327, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37164897

RESUMO

PURPOSE: Monte Carlo (MC) simulations can be used to accurately simulate dose and linear energy transfers (LET) distributions, thereby allowing for the calculation of the relative biological effectiveness (RBE) of protons. We present hereby the validation and implementation of a workflow for the Monte Carlo modelling of the double scattered and pencil beam scanning proton beamlines at our institution. METHODS: The TOPAS/Geant4 MC model of the clinical nozzle has been comprehensively validated against measurements. The validation also included a comparison between simulated clinical treatment plans for four representative patients and the clinical treatment planning system (TPS). Moreover, an in-house tool implemented in Python was tested to assess the variable RBE-weighted dose in proton plans, which was illustrated for a patient case with a developing radiation-induced toxicity. RESULTS: The simulated range and modulation width closely matches the measurements. Gamma-indexes (3%/3mm 3D), which compare the TPS and MC computations, showed a passing rate superior to 98%. The calculated RBE-weighted dose presented a slight increase at the necrosis location, within the PTV margins. This indicates the need for reporting on the physical and biological effects of irradiation in high dose regions, especially at the healthy tissues and increased LET distributions location. CONCLUSION: The results demonstrate that the Monte Carlo method can be used to independently validate a TPS calculation, and to estimate LET distributions. The features of the in-house tool can be used to correlate LET and RBE-weighted dose distributions with the incidence of radiation-induced toxicities following proton therapy treatments.


Assuntos
Terapia com Prótons , Lesões por Radiação , Humanos , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Prótons , Estudos Retrospectivos , Dosagem Radioterapêutica , Método de Monte Carlo , Fluxo de Trabalho , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos
5.
J Int Neuropsychol Soc ; 29(8): 798-811, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36323679

RESUMO

OBJECTIVE: There is increasing interest in the utilization of proton beam radiation therapy (PRT) to treat pediatric brain tumors based upon presumed advantages over traditional photon radiation therapy (XRT). PRT provides more conformal radiation to the tumor with reduced dose to healthy brain parenchyma. Less radiation exposure to brain tissue beyond the tumor is thought to reduce neuropsychological sequelae. This systematic review aimed to provide an overview of published studies comparing neuropsychological outcomes between PRT and XRT. METHOD: PubMed, PsychINFO, Embase, Web of Science, Scopus, and Cochrane were systematically searched for peer-reviewed published studies that compared neuropsychological outcomes between PRT and XRT in pediatric brain tumor patients. RESULTS: Eight studies were included. Six of the studies utilized retrospective neuropsychological data; the majority were longitudinal studies (n = 5). XRT was found to result in lower neuropsychological functioning across time. PRT was associated with generally stable neuropsychological functioning across time, with the exception of working memory and processing speed, which showed variable outcomes across studies. However, studies inconsistently included or considered medical and sociodemographic differences between treatment groups, which may have impacted neuropsychological outcomes. CONCLUSIONS: Despite methodological limitations, including limited baseline neuropsychological evaluations, temporal variability between radiation treatment and first evaluation or initial and follow-up evaluations, and heterogenous samples, there is emerging evidence of sociodemographic inequities in access to PRT. With more institutions dedicating funding towards PRT, there may be the opportunity to objectively evaluate the neuropsychological benefits of patients matched on medical and sociodemographic variables.


Assuntos
Neoplasias Encefálicas , Terapia com Prótons , Criança , Humanos , Prótons , Estudos Retrospectivos , Terapia com Prótons/efeitos adversos , Acessibilidade aos Serviços de Saúde
6.
Radiother Oncol ; 175: 47-55, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35917900

RESUMO

BACKGROUND AND PURPOSE: A fixed relative biological effectiveness (RBE) of 1.1 (RBE1.1) is used clinically in proton therapy even though the RBE varies with properties such as dose level and linear energy transfer (LET). We therefore investigated if symptomatic brainstem toxicity in pediatric brain tumor patients treated with proton therapy could be associated with a variable LET and RBE. MATERIALS AND METHODS: 36 patients treated with passive scattering proton therapy were selected for a case-control study from a cohort of 954 pediatric brain tumor patients. Nine children with symptomatic brainstem toxicity were each matched to three controls based on age, diagnosis, adjuvant therapy, and brainstem RBE1.1 dose characteristics. Differences across cases and controls related to the dose-averaged LET (LETd) and variable RBE-weighted dose from two RBE models were analyzed in the high-dose region. RESULTS: LETd metrics were marginally higher for cases vs. controls for the majority of dose levels and brainstem substructures. Considering areas with doses above 54 Gy(RBE1.1), we found a moderate trend of 13% higher median LETd in the brainstem for cases compared to controls (P =.08), while the difference in the median variable RBE-weighted dose for the same structure was only 2% (P =.6). CONCLUSION: Trends towards higher LETd for cases compared to controls were noticeable across structures and LETd metrics for this patient cohort. While case-control differences were minor, an association with the observed symptomatic brainstem toxicity cannot be ruled out.


Assuntos
Neoplasias Encefálicas , Terapia com Prótons , Humanos , Criança , Eficiência Biológica Relativa , Transferência Linear de Energia , Terapia com Prótons/efeitos adversos , Estudos de Casos e Controles , Planejamento da Radioterapia Assistida por Computador , Tronco Encefálico , Neoplasias Encefálicas/radioterapia , Método de Monte Carlo
7.
Prostate ; 82(15): 1438-1446, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35915875

RESUMO

BACKGROUND: Stereotactic body radiation therapy (SBRT) has gradually been recognized as favorable curative treatment for localized prostate cancer (PC). However, the high rate of erectile dysfunction (ED) after traditional photon-based SBRT remains an ongoing challenge that greatly impacts the quality of life of PC survivors. Modern proton therapy allows higher conformal SBRT delivery and has the potential to reduce ED occurrence but its cost-effectiveness remains uninvestigated. METHODS: A Markov decision model was designed to evaluate the cost-effectiveness of proton SBRT versus photon SBRT in reducing irradiation-related ED. Base-case evaluation was performed on a 66-year-old (median age of PC) localized PC patient with normal pretreatment erectile function. Further, stratified analyses were performed for different age groups (50, 55, 60, 65, 70, and 75 years) and threshold analyses were conducted to estimate cost-effective scenarios. A Chinese societal willingness-to-pay (WTP) threshold (37,653 US dollars [$])/quality-adjusted life-year [QALY]) was adopted. RESULTS: For the base case, protons provided an additional 0.152 QALY at an additional cost of $7233.4, and the incremental cost-effectiveness ratio was $47,456.5/QALY. Protons was cost-effective for patients ≤62-year-old at the WTP of China (≤66-year-old at a WTP of $50,000/QALY; ≤73-year-old at a WTP of $100,000/QALY). For patients at median age, once the current proton cost ($18,000) was reduced to ≤$16,505.7 or the patient had a life expectancy ≥88 years, protons were cost-effective at the WTP of China. CONCLUSIONS: Upon assumption-based modeling, the results of current study support the use of proton SBRT in younger localized PC patients who are previously potent, for better preservation of erectile function. The findings await further validation using data from future comparative clinical trials.


Assuntos
Disfunção Erétil , Neoplasias da Próstata , Terapia com Prótons , Idoso , Análise Custo-Benefício , Disfunção Erétil/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/radioterapia , Terapia com Prótons/efeitos adversos , Prótons , Qualidade de Vida
8.
Phys Med Biol ; 67(12)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35613603

RESUMO

Objective. Patients who receive proton beam therapy are exposed to unwanted stray neutrons. Stray radiations increase the risk of late effects in normal tissues, such as second cancers and cataracts, and may cause implanted devices such as pacemakers to malfunction. Compared to therapeutic beams, little attention has been paid to modeling stray neutron exposures. In the past decade, substantial progress was made to develop semiempirical models of stray neutron dose equivalent, but models to routinely calculate neutron absorbed dose and kerma are still lacking. The objective of this work was to develop a new physics based analytical model to calculate neutron spectral fluence, kerma, and absorbed dose in a water phantom.Approach. We developed the model using dosimetric data from Monte Carlo simulations and neutron kerma coefficients from the literature. The model explicitly considers the production, divergence, scattering, and attenuation of neutrons. Neutron production was modeled for 120-250 MeV proton beams impinging on a variety of materials. Fluence, kerma and dose calculations were performed in a 30 × 180 × 44 cm3phantom at points up to 43 cm in depth and 80 cm laterally.Main Results. Predictions of the analytical model agreed reasonably with corresponding values from Monte Carlo simulations, with a mean difference in average energy deposited of 20%, average kerma coefficient of 21%, and absorbed dose to water of 49%.Significance. The analytical model is simple to implement and use, requires less configuration data that previously reported models, and is computationally fast. This model appears potentially suitable for integration in treatment planning system, which would enable risk calculations in prospective and retrospective cases, providing a powerful tool for epidemiological studies and clinical trials.


Assuntos
Terapia com Prótons , Exposição à Radiação , Humanos , Método de Monte Carlo , Nêutrons , Física , Estudos Prospectivos , Terapia com Prótons/efeitos adversos , Radiometria/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Água
9.
JAMA Netw Open ; 5(4): e229025, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35476066

RESUMO

Importance: Proton beam therapy (PBT) is a potentially superior technology to photon radiotherapy for tumors with complex anatomy, those surrounded by sensitive tissues, and childhood cancers. Objective: To assess patterns of use of PBT according to the present American Society of Radiation Oncology (ASTRO) clinical indications in the US. Design, Setting, and Participants: Individuals newly diagnosed with cancer between 2004 and 2018 were selected from the National Cancer Database. Data analysis was performed from October 4, 2021, to February 22, 2022. ASTRO's Model Policies (2017) were used to classify patients into group 1, for which health insurance coverage for PBT treatment is recommended, and group 2, for which coverage is recommended only if additional requirements are met. Main Outcomes and Measures: Use of PBT. Results: Of the 5 919 368 patients eligible to receive PBT included in the study, 3 206 902 were female (54.2%), and mean (SD) age at diagnosis was 62.6 (12.3) years. Use of PBT in the US increased from 0.4% in 2004 to 1.2% in 2018 (annual percent change [APC], 8.12%; P < .001) due to increases in group 1 from 0.4% in 2010 to 2.2% in 2018 (APC, 21.97; P < .001) and increases in group 2 from 0.03% in 2014 to 0.1% in 2018 (APC, 30.57; P < .001). From 2010 to 2018, among patients in group 2, PBT targeted to the breast increased from 0.0% to 0.9% (APC, 51.95%), and PBT targeted to the lung increased from 0.1% to 0.7% (APC, 28.06%) (P < .001 for both). Use of PBT targeted to the prostate decreased from 1.4% in 2011 to 0.8% in 2014 (APC, -16.48%; P = .03) then increased to 1.3% in 2018 (APC, 12.45; P < .001). Most patients in group 1 treated with PBT had private insurance coverage in 2018 (1039 [55.4%]); Medicare was the most common insurance type among those in group 2 (1973 [52.5%]). Conclusions and Relevance: The findings of this study show an increase in the use of PBT in the US between 2004 to 2018; prostate was the only cancer site for which PBT use decreased temporarily between 2011 and 2014, increasing again between 2014 and 2018. These findings may be especially relevant for Medicare radiation oncology coverage policies.


Assuntos
Neoplasias , Terapia com Prótons , Radioterapia (Especialidade) , Idoso , Criança , Feminino , Humanos , Cobertura do Seguro , Masculino , Medicare , Neoplasias/epidemiologia , Neoplasias/etiologia , Neoplasias/radioterapia , Terapia com Prótons/efeitos adversos , Estados Unidos
10.
Int J Radiat Oncol Biol Phys ; 112(1): 237-246, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34425196

RESUMO

PURPOSE: This study aimed to investigate the correlation between imaging changes in brain normal tissue and the spatial distribution of linear energy transfer (LET) for a cohort of patients with meningioma treated with scanned proton beams. Then, assuming imaging changes are induced by cell lethality, we studied the correlation between normal tissue complication probability and LET. METHODS AND MATERIALS: Magnetic resonance imaging T2/fluid attenuated inversion recovery acquired at different intervals after proton radiation were coregistered with the planning computed tomography (CT) images from 26 patients with meningioma with abnormalities after proton radiation therapy. For this purpose, the T2/fluid attenuated inversion recovery areas not on the original magnetic resonance images were contoured, and the LET values for each voxel in the patient geometry were calculated to investigate the correlation between the position of imaging changes and the LET at those positions. To separate the effect of the dose as the inductor of these changes, we compared the LET in these areas with a sample of voxels matching the dose distributions across the image change areas. Patients with a higher LET in image change areas were grouped to verify whether they shared common characteristics. RESULTS: Eleven of the patients showed higher dose-averaged LET (LETd) in imaging change regions than in the group of voxels with the same dose. This group of patients had significantly shallower targets for their treatment than the other 15 and used fewer beams and angles. CONCLUSIONS: This study points toward the possibility that areas with imaging change are more likely to occur in regions with high dose or in areas with lower dose but increased LETd. The effect of LETd on imaging changes seems to be more relevant when treating superficial lesions with few nonopposed beams. However, most patients did not show a spatial correlation between their image changes and the LETd values, limiting the cases for the possible role of high LET as a toxicity inductor.


Assuntos
Neoplasias Meníngeas , Meningioma , Terapia com Prótons , Encéfalo , Humanos , Transferência Linear de Energia , Imageamento por Ressonância Magnética , Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/radioterapia , Meningioma/diagnóstico por imagem , Meningioma/radioterapia , Método de Monte Carlo , Probabilidade , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
11.
Int J Radiat Oncol Biol Phys ; 112(1): 158-166, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34348176

RESUMO

PURPOSE: For curative treatment of Hodgkin lymphoma, radiation therapy benefit must be weighed against toxicity. Although more costly, proton radiation therapy reduces dose to healthy tissue, potentially improving the therapeutic ratio compared with photons. We sought to determine the cost-effectiveness of proton versus photon therapy for mediastinal Hodgkin lymphoma (MHL) based on reduced heart disease. METHODS AND MATERIALS: Our model approach was 2-fold: (1) Use patient-level dosimetric information for a cost-effectiveness analysis using a Markov cohort model. (2) Use population-based data to develop guidelines for policymakers to determine thresholds of proton therapy favorability for a given photon dose. The HD14 trial informed relapse risk; coronary heart disease risk was informed by the Framingham risk calculator modified by the mean heart dose (MHD) from radiation. Sensitivity analyses assessed model robustness and identified the most influential model assumptions. A 30-year-old adult with MHL was the base case using 30.6-Gy proton therapy versus photon intensity modulated radiation therapy. RESULTS: Proton therapy was not cost-effective in the base case for male ($129,000/ quality-adjusted life years [QALYs]) or female patients ($196,000/QALY). A 5-Gy MHD decrease was associated with proton therapy incremental cost-effectiveness ratio <$100,000/QALY in 40% of scenarios. The hazard ratio associating MHD and heart disease was the most influential clinical parameter. CONCLUSIONS: Proton therapy may be cost-effective a select minority of patients with MHL based on age, sex, and MHD reduction. We present guidance for clinicians using MHD to aid decision-making for radiation therapy modality.


Assuntos
Doença de Hodgkin , Terapia com Prótons , Adulto , Análise Custo-Benefício , Feminino , Doença de Hodgkin/radioterapia , Humanos , Masculino , Recidiva Local de Neoplasia/etiologia , Terapia com Prótons/efeitos adversos , Terapia com Prótons/métodos , Anos de Vida Ajustados por Qualidade de Vida
12.
Phys Med Biol ; 67(3)2022 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-34969024

RESUMO

Objective. As cancer survivorship increases, there is growing interest in minimizing the late effects of radiation therapy such as radiogenic second cancer, which may occur anywhere in the body. Assessing the risk of late effects requires knowledge of the dose distribution throughout the whole body, including regions far from the treatment field, beyond the typical anatomical extent of clinical computed tomography (CT) scans.Approach. A hybrid phantom was developed which consists of in-field patient CT images extracted from ground truth whole-body CT scans, out-of-field mesh phantoms scaled to basic patient measurements, and a blended transition region. Four of these hybrid phantoms were created, representing male and female patients receiving proton therapy treatment in pelvic and cranial sites. To assess the performance of the hybrid approach, we simulated treatments using the hybrid phantoms, the scaled and unscaled mesh phantoms, and the ground truth whole-body CTs. We calculated absorbed dose and equivalent dose in and outside of the treatment field, with a focus on neutrons induced in the patient by proton therapy. Proton and neutron dose was calculated using a general purpose Monte Carlo code.Main results. The hybrid phantom provided equal or superior accuracy in calculated organ dose and equivalent dose values relative to those obtained using the mesh phantoms in 78% in all selected organs and calculated dose quantities. Comparatively the default mesh and scaled mesh were equal or superior to the other phantoms in 21% and 28% of cases respectively.Significance. The proposed methodology for hybrid synthesis provides a tool for whole-body organ dose estimation for individual patients without requiring CT scans of their entire body. Such a capability would be useful for personalized assessment of late effects and risk-optimization of treatment plans.


Assuntos
Nêutrons , Terapia com Prótons , Feminino , Humanos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Terapia com Prótons/efeitos adversos , Doses de Radiação , Radiometria/métodos
13.
Radiother Oncol ; 163: 143-149, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34461183

RESUMO

PURPOSE: We investigated the relationship between RBE-weighted dose (DRBE) calculated with constant (cRBE) and variable RBE (vRBE), dose-averaged linear energy transfer (LETd) and the risk of radiographic changes in skull base patients treated with protons. METHODS: Clinical treatment plans of 45 patients were recalculated with Monte Carlo tool FRED. Radiographic changes (i.e. edema and/or necrosis) were identified by MRI. Dosimetric parameters for cRBE and vRBE were computed. Biological margin extension and voxel-based analysis were employed looking for association of DRBE(vRBE) and LETd with brain edema and/or necrosis. RESULTS: When using vRBE, Dmax in the brain was above the highest dose limits for 38% of patients, while such limit was never exceeded assuming cRBE. Similar values of Dmax were observed in necrotic regions, brain and temporal lobes. Most of the brain necrosis was in proximity to the PTV. The voxel-based analysis did not show evidence of an association with high LETd values. CONCLUSIONS: When looking at standard dosimetric parameters, the higher dose associated with vRBE seems to be responsible for an enhanced risk of radiographic changes. However, as revealed by a voxel-based analysis, the large inter-patient variability hinders the identification of a clear effect for high LETd.


Assuntos
Terapia com Prótons , Neoplasias da Base do Crânio , Encéfalo/diagnóstico por imagem , Humanos , Método de Monte Carlo , Necrose/etiologia , Terapia com Prótons/efeitos adversos , Planejamento da Radioterapia Assistida por Computador , Eficiência Biológica Relativa , Neoplasias da Base do Crânio/diagnóstico por imagem , Neoplasias da Base do Crânio/radioterapia
14.
Int J Radiat Oncol Biol Phys ; 111(1): 186-195, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33845147

RESUMO

PURPOSE: Cardiac implantable electronic devices (CIED) are sensitive to scattered secondary neutrons from proton beam irradiation. This experimental in vitro study investigated risk of CIED errors during pencil beam proton therapy. METHODS AND MATERIALS: We used 62 explanted CIEDs from 4 manufacturers; 49 CIEDs were subjected to a simulated clinical protocol with daily 2 Gy relative biological effectiveness fractions prescribed to the phantom. Devices were located at 3 different lateral distances from the spread-out Bragg peak to investigate the risk of permanent or temporary device errors. Additionally, 13 devices with leads connected were monitored live during consecutive irradiations to investigate the risk of noise, over- or undersense, pace inhibition, and inappropriate shock therapy. RESULTS: We detected 61 reset errors in 1728 fractions, and all except 1 CIED were reprogrammed to normal function. All, except 1 reset, occurred in devices from the same manufacturer. These were successfully reprogrammed to normal function. The 1 remaining CIED was locked in permanent safety mode. Secondary neutron dose, as estimated by Monte Carlo simulations, was found to significantly increase the odds of CIED resets by 55% per mSv. Clinically significant battery depletion was observed in 5 devices. We observed no noise, over- or undersense, pace inhibition, or inappropriate shock therapy during 362 fractions of live monitoring. CONCLUSIONS: Reprogrammable CIED reset was the most commonly observed malfunction during proton therapy, and reset risk depended on secondary neutron exposure. The benefits of proton therapy are expected to outweigh the risk of CIED malfunctioning for most patients.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Terapia com Prótons/efeitos adversos , Falha de Equipamento , Humanos , Método de Monte Carlo , Nêutrons
15.
Radiat Res ; 195(6): 541-548, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33826742

RESUMO

The uncertainty associated with the relative biological effectiveness (RBE) in proton therapy, particularly near the Bragg peak (BP), has led to the shift towards biological-based treatment planning. Proton RBE uncertainty has recently been reported as a possible cause for brainstem necrosis in pediatric patients treated with proton therapy. Despite this, in vivo studies have been limited due to the complexity of accurate delivery and absolute dosimetry. The purpose of this investigation was to create a precise and efficient method of treating the mouse spinal cord with various portions of the proton Bragg curve and to quantify associated uncertainties for the characterization of proton RBE. Mice were restrained in 3D printed acrylic boxes, shaped to their external contour, with a silicone insert extending down to mold around the mouse. Brass collimators were designed for parallel opposed beams to treat the spinal cord while shielding the brain and upper extremities of the animal. Up to six animals may be accommodated for simultaneous treatment within the restraint system. Two plans were generated targeting the cervical spinal cord, with either the entrance (ENT) or the BP portion of the beam. Dosimetric uncertainty was measured using EBT3 radiochromic film with a dose-averaged linear energy transfer (LETd) correction. Positional uncertainty was assessed by collecting a library of live mouse scans (n = 6 mice, two independent scans per mouse) and comparing the following dosimetric statistics from the mouse cervical spinal cord: Volume receiving 90% of the prescription dose (V90); mean dose to the spinal cord; and LETd. Film analysis results showed the dosimetric uncertainty to be ±1.2% and ±5.4% for the ENT and BP plans, respectively. Preliminary results from the mouse library showed the V90 to be 96.3 ± 4.8% for the BP plan. Positional uncertainty of the ENT plan was not measured due to the inherent robustness of that treatment plan. The proposed high-throughput mouse proton irradiation setup resulted in accurate dose delivery to mouse spinal cords positioned along the ENT and BP. Future directions include adapting the setup to account for weight fluctuations in mice undergoing fractionated irradiation.


Assuntos
Terapia com Prótons/efeitos adversos , Medula Espinal/efeitos da radiação , Animais , Relação Dose-Resposta à Radiação , Camundongos , Radiometria , Incerteza
16.
Int J Radiat Oncol Biol Phys ; 110(5): 1496-1504, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33677051

RESUMO

PURPOSE: Young patients, including pediatric, adolescent, and young adult (YA) patients, are most likely to benefit from the reduced integral dose of proton beam radiation therapy (PBT) resulting in fewer late toxicities and secondary malignancies. This study sought to examine insurance approval and appeal outcomes for PBT among YA patients compared with pediatric patients at a large-volume proton therapy center. METHODS AND MATERIALS: We performed a cross-sectional cohort study of 284 consecutive patients aged 0 to 39 years for whom PBT was recommended in 2018 through 2019. Pediatric patients were defined as aged 0 to 18 years and YA patients 19 to 39 years. Rates of approval, denials, and decision timelines were calculated. Tumor type and location were also evaluated as factors that may influence insurance decisions. RESULTS: A total of 207 patients (73%) were approved for PBT at initial request. YA patients (n = 68/143, 48%) were significantly less likely to receive initial approval compared with pediatric patients (n = 139/141; 99%) (P < .001). Even after 47% (n = 35 of 75) of the PBT denials for YA patients were overturned, YAs had a significantly lower final PBT approval (72% vs pediatric 99%; P < .001). The median wait time was also significantly longer for YA patients (median, 8 days; interquartile range [IQR] 3-17 vs median, 2 days; IQR, 0-6; P < .001). In those patients requiring an appeal, the median wait time was 16 days (IQR, 9-25). CONCLUSION: Given the decades of survivorship of YA patients, PBT is an important tool to reduce late toxicities and secondary malignancies. Compared with pediatric patients, YA patients are significantly less likely to receive insurance approval for PBT. Insurance denials and subsequent appeal requests result in significant delays for YA patients. Insurers need to re-examine their policies to include expedited decisions and appeals and removal of arbitrary age cutoffs so that YA patients can gain easier access to PBT. Furthermore, consensus guidelines encouraging greater PBT access for YA may be warranted from both medical societies and/or AYA experts.


Assuntos
Fatores Etários , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Cobertura do Seguro/estatística & dados numéricos , Reembolso de Seguro de Saúde , Seguro Saúde/estatística & dados numéricos , Terapia com Prótons/estatística & dados numéricos , Adolescente , Adulto , Neoplasias Encefálicas/radioterapia , Criança , Pré-Escolar , Radiação Cranioespinal/estatística & dados numéricos , Estudos Transversais , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Lactente , Recém-Nascido , Seguradoras , Reembolso de Seguro de Saúde/estatística & dados numéricos , Neoplasias Induzidas por Radiação/prevenção & controle , Terapia com Prótons/efeitos adversos , Neoplasias da Coluna Vertebral/radioterapia , Fatores de Tempo , Adulto Jovem
17.
Scand J Caring Sci ; 35(3): 796-804, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32720338

RESUMO

BACKGROUND: Currently, no available tool easily and effectively measures both the frequency, intensity and distress of symptoms among patients receiving radiotherapy. A core symptom set (fatigue, insomnia, pain, appetite loss, cognitive problems, anxiety, nausea, depression, constipation, diarrhoea and skin reaction) has been identified and assessed across oncology research to better understand the pattern of symptoms and treatment side effects. AIM: The aim was to develop a tool measuring the multiple-symptom experience in patients undergoing radiotherapy and evaluate its psychometric properties (validity, reliability and responsiveness). DESIGN: This study has a prospective, longitudinal and quantitative design. METHODS: We developed a patient-reported outcome questionnaire, the Radiotherapy-Related Symptoms Assessment Scale to assess the frequency, intensity and distress associated with symptoms. Patients (n = 175) with brain tumours undergoing proton beam therapy completed the Radiotherapy-Related Symptoms Assessment Scale and the health-related quality of life questionnaire (EORTC QLQ-C30) during treatment. We assessed the validity, reliability and responsiveness of the Radiotherapy-Related Symptoms Assessment Scale and evaluated the validity against QLQ-C30. RESULTS: There were significant questionnaire-questionnaire correlations regarding selected items, primarily fatigue, insomnia and pain, indicating satisfactory criterion-related validity. The Radiotherapy-Related Symptoms Assessment Scale had fair to good retest reliability. CONCLUSION: The Radiotherapy-Related Symptoms Assessment Scale is a valid instrument for assessing symptom intensity and distress in patients with brain tumour undergoing PBT, with psychometric properties within the expected range. The Radiotherapy-Related Symptoms Assessment Scale provides nurses with substantial information on symptom experience but requires little effort from the patient. Additional studies are required to further assess the psychometric properties in patients with different cancer diagnoses receiving conventional radiotherapy.


Assuntos
Neoplasias Encefálicas , Terapia com Prótons , Neoplasias Encefálicas/radioterapia , Humanos , Estudos Prospectivos , Terapia com Prótons/efeitos adversos , Psicometria , Qualidade de Vida , Reprodutibilidade dos Testes , Inquéritos e Questionários , Avaliação de Sintomas
18.
Br J Radiol ; 94(1121): 20200354, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33237825

RESUMO

OBJECTIVES: To assess if excess absolute risk (EAR) of radiation-induced solid cancer can be used to rank radiotherapy plans for treatment of Hodgkin lymphoma (HL) in a statistically significant way. METHODS: EAR models, calibrated with data from the Life Span Study and HL survivors, have been incorporated into a voxelised risk-calculation software, which is used to compare four treatment modalities planned for five virtual HL patients. Organ-specific parameters are generated repeatedly in a Monte Carlo fashion to model their uncertainties. This in turn enables a quantitative estimation of the EAR uncertainties. RESULTS: Parameter-driven uncertainties on total EAR are around 13%, decreasing to around 2-5% for relative EAR comparisons. Total EAR estimations indicate that intensity modulated proton therapy decreases the average risk by 40% compared to the intensity modulated radiation therapy plan, 28% compared to the volumetric modulated arc therapy plan whereas the three-dimensional conformal radiation therapy plan is equivalent within the uncertainty. CONCLUSION: Relative EAR is a useful metric for distinguishing between radiotherapy plans in terms of second cancer risk. ADVANCES IN KNOWLEDGE: Relative EAR is not dominated by model or parameter uncertainties and can be used to guide the choice of radiotherapy for HL patients.


Assuntos
Doença de Hodgkin/radioterapia , Neoplasias Induzidas por Radiação/etiologia , Segunda Neoplasia Primária/etiologia , Terapia com Prótons/métodos , Radioterapia Conformacional/métodos , Sobreviventes de Câncer , Doença de Hodgkin/mortalidade , Humanos , Método de Monte Carlo , Terapia com Prótons/efeitos adversos , Radioterapia Conformacional/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Medição de Risco/métodos , Fatores de Tempo , Incerteza
19.
Int J Radiat Oncol Biol Phys ; 107(3): 449-454, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32240774

RESUMO

PURPOSE: A prospective trial of proton therapy for breast cancer revealed an increased rib fracture rate of 7%, which is higher than the expected rate based on the literature on photon therapies. We aim to evaluate the hypothesis that the increased relative biological effectiveness (RBE) at the distal edge of proton beams is the cause. METHODS AND MATERIALS: We combined the cohort from the prospective clinical trial and a retrospective cohort from a database. Monte Carlo simulations were performed to recalculate the physical dose and dose-averaged linear energy transfer (LETd). The first 10 ribs and fracture areas in patients with fractures were contoured and deformably registered. The LETd-weighted dose was used as a surrogate for biological effectiveness and compared with the conventional fixed RBE of 1.1. Dose to 0.5 cm3 of the ribs (D0.5) was selected to analyze the dose-response relationship using logistic regression. We chose an alpha/beta ratio of 3 to calculate the biological effective dose in Gy3(RBE). RESULTS: Thirteen of 203 patients in the cohorts exhibited a total of 25 fractures. The LETd in fractured areas is increased (6.1 ± 2.0 keV/µm, mean ± standard deviation), suggesting possible end-of-range radiobiological effects with increased RBE. The D0.5 of the fractured ribs is 80.3 ± 9.4 Gy3(RBE) with a generic factor of 1.1 and is relatively low compared with historical photon results. On the other hand, the D0.5 of the fractured ribs is 100.0 ± 12.5 Gy3(RBE) using the LETd-based model with a dose-response curve that is more consistent with historical photon data. CONCLUSIONS: The increased rib fracture rate seen in our trial is probably associated with the increased LETd and RBE at the distal edge of proton beams. This phenomenon warrants further investigation and possible integration of LETd into treatment planning and optimization in proton therapy.


Assuntos
Neoplasias da Mama/radioterapia , Terapia com Prótons/efeitos adversos , Radiobiologia , Fraturas das Costelas/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ensaios Clínicos como Assunto , Humanos , Pessoa de Meia-Idade , Método de Monte Carlo , Estudos Retrospectivos
20.
Phys Med ; 70: 28-38, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31954210

RESUMO

PURPOSE: To present a planning strategy for proton pencil-beam scanning when titanium implants need to be crossed by the beam. METHODS: We addressed three issues: the implementation of a CT calibration curve to assign to titanium the correct stopping power; the effect of artefacts on CT images and their reduction by a dedicated algorithm; the differences in dose computation depending on the dose engine, pencil-beam vs Monte-Carlo algorithms. We performed measurement tests on a simple cylinder phantom and on a real implant. These phantoms were irradiated with three geometries (single spots, uniform mono-energetic layer and uniform box), measuring the exit dose either by radio-chromic film or multi-layer ionization chamber. The procedure was then applied on two patients treated for chordoma. RESULTS: We had to set in the calibration curve a mass density equal to 4.37 g/cm3 to saturated Hounsfield Units, in order to have the correct stopping power assigned to titanium in TPS. CT artefact reduction algorithm allowed a better reconstruction of the shape and size of the implant. Monte-Carlo resulted accurate in computing the dose distribution whereas the pencil-beam algorithm failed due to sharp density interfaces between titanium and the surrounding material. Finally, the treatment plans obtained on two patients showed the impact of the dose engine algorithm, with 10-20% differences between pencil-beam and Monte-Carlo in small regions distally to the titanium screws. CONCLUSION: The described combination of CT calibration, artefacts reduction and Monte-Carlo computation provides a reliable methodology to compute dose in patients with titanium implants.


Assuntos
Cordoma/terapia , Próteses e Implantes , Terapia com Prótons/efeitos adversos , Titânio/química , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Calibragem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos