1.
Clin Lab ; 70(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747911

RESUMO

BACKGROUND: This study aims to evaluate the ability of laboratories to perform spinal muscular atrophy (SMA) genetic testing in newborns based on dried blood spot (DBS) samples, and to provide reference data and advance preparation for establishing the pilot external quality assessment (EQA) scheme for SMA genetic testing of newborns in China. METHODS: The pilot EQA scheme contents and evaluation principles of this project were designed by National Center for Clinical Laboratories (NCCL), National Health Commission. Two surveys were carried out in 2022, and 5 batches of blood spots were submitted to the participating laboratory each time. All participating laboratories conducted testing upon receiving samples, and test results were submitted to NCCL within the specified date. RESULTS: The return rates were 75.0% (21/28) and 95.2% (20/21) in the first and second surveys, respectively. The total return rate of the two examinations was 83.7% (41/49). Nineteen laboratories (19/21, 90.5%) had a full score passing on the first survey, while in the second survey twenty laboratories (20/20, 100%) scored full. CONCLUSIONS: This pilot EQA survey provides a preliminary understanding of the capability of SMA genetic testing for newborns across laboratories in China. A few laboratories had technical or operational problems in testing. It is, therefore, of importance to strengthen laboratory management and to improve testing capacity for the establishment of a national EQA scheme for newborn SMA genetic testing.


Assuntos
Testes Genéticos , Atrofia Muscular Espinal , Triagem Neonatal , Humanos , Recém-Nascido , Atrofia Muscular Espinal/diagnóstico , Atrofia Muscular Espinal/genética , Projetos Piloto , Testes Genéticos/normas , Testes Genéticos/métodos , Triagem Neonatal/normas , Triagem Neonatal/métodos , China , Teste em Amostras de Sangue Seco/normas , Teste em Amostras de Sangue Seco/métodos , Garantia da Qualidade dos Cuidados de Saúde , Laboratórios Clínicos/normas , Proteína 1 de Sobrevivência do Neurônio Motor/genética
2.
J Appl Lab Med ; 9(3): 512-525, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38384160

RESUMO

BACKGROUND: In addition to newborn screening, dried blood spots (DBSs) are used for a wide variety of analytes for clinical, epidemiological, and research purposes. Guidelines on DBS collection, storage, and transport are available, but it is suggested that each laboratory should establish its own acceptance criteria. METHODS: An optical scanning device was developed to assess the quality of DBSs received in the newborn screening laboratory from 11 maternity wards between 2013 and 2018. The algorithm was adjusted to agree with the visual examination consensus of experienced laboratory personnel. Once validated, the algorithm was used to categorize DBS specimens as either proper or improper. Improper DBS specimens were further divided based on 4 types of specimen defects. RESULTS: In total, 27 301 DBSs were analyzed. Compared with an annual DBS rejection rate of about 1%, automated scanning rejected 26.96% of the specimens as having at least one defect. The most common specimen defect was multi-spotting (ragged DBS, 19.13%). Among maternity wards, improper specimen rates varied greatly between 5.70% and 49.92%. CONCLUSIONS: Improper specimen rates, as well as the dominant type of defect(s), are mainly institution-dependent, with various maternity wards consistently showing specific patterns of both parameters over time. Although validated in agreement with experienced laboratory personnel consensus, automated analysis rejects significantly more specimens. While continuous staff training, specimen quality monitoring, and problem-reporting to maternities is recommended, a thorough quality assessment strategy should also be implemented by every newborn screening laboratory. An important role in this regard may be played by automation in the form of optical scanning devices.


Assuntos
Algoritmos , Teste em Amostras de Sangue Seco , Triagem Neonatal , Humanos , Triagem Neonatal/métodos , Triagem Neonatal/normas , Recém-Nascido , Teste em Amostras de Sangue Seco/métodos , Teste em Amostras de Sangue Seco/normas , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas
3.
Sci Rep ; 13(1): 13008, 2023 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-37563249

RESUMO

Dried blood spot (DBS) sample collection has been suggested as a less invasive, cheaper and more convenient alternative to venepuncture, which requires trained personnel, making it a potentially viable approach for self-collection of blood on a large scale. We examine whether participants in a longitudinal survey were willing to provide a DBS sample in different interview settings, and how resulting cardiovascular risk biomarkers compared with those from venous blood to calculate clinical risk. Participants of the Understanding Society Innovation Panel, a representative sample of UK households, were randomly assigned to three modes of interview. Most participants (84%) were interviewed in their allocated mode. Participants (n = 2162) were interviewed by a nurse who collected both a blood sample by venepuncture and a DBS card ('nurse collection') or participants were seen by an interviewer or took part in the survey online to self-collect a DBS card ('self-collection'). All DBS cards were returned in the post after the sample had dried. Lipids (total cholesterol, HDL-cholesterol, triglycerides), HbA1c and C-reactive protein were measured in venous and DBS samples and equivalence was calculated. The resultant values were used to confirm equivalent prevalence of risk of cardiovascular disease in each type of blood sample by mode of participation. Of participants interviewed by a nurse 69% consented to venous blood sample and 74% to a DBS sample, while in the self-collection modes, 35% consented to DBS collection. Demographic characteristics of participants in self-collection mode was not different to those in nurse collection mode. The percentage of participants with clinically raised biomarkers did not significantly differ between type of blood collection (for example, 62% had high cholesterol (> 5 mmol/l) measured by venepuncture and 67% had high cholesterol within the self-collected DBS sample (p = 0.13)). While self-collected DBS sampling had a lower response rate to DBS collected by a nurse, participation did not vary by key demographic characteristics. This study demonstrates that DBS collection is a feasible method of sample collection that can provide acceptable measures of clinically relevant biomarkers, enabling the calculation of population levels of cardiovascular disease risk.


Assuntos
Doenças Cardiovasculares , Humanos , Doenças Cardiovasculares/diagnóstico , Fatores de Risco , Teste em Amostras de Sangue Seco/métodos , Biomarcadores , HDL-Colesterol , Fatores de Risco de Doenças Cardíacas
4.
Anal Methods ; 15(29): 3532-3542, 2023 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-37435749

RESUMO

The blood hematocrit (Hct) level provides vital information about a person's health. Traditional Hct measurement equipment relies heavily on infrastructure and skilled manpower, limiting its broad implementation in resource-limited contexts. Therefore, we developed a simple, reagent-free, non-destructive, smartphone-integrated paper-based device for Hct measurement by analyzing blood-spreading area on a paper substrate. Blood spreading area was found to be dependent on the Hct value, paper properties, and assay duration. This device was calibrated using a custom-made Python algorithm with 10 µl of blood, which produced a sensitivity of -1.90 ± 0.03 mm2/Hct (%) with a LOD as low as 2.17% Hct. The device linear range (8.8 to 58% Hct) is wide enough to cover the clinically relevant range of blood Hct (%). Furthermore, this Python algorithm was coupled with a user-friendly and clinically beneficial Android application (app) to establish an automated tool for quantitative estimation. Comparing the app performance with the result obtained from the gold standard hematology analyzer using blood from 87 subjects reveals a strong correlation (r = 0.99), an average bias of 0.15 with limits of agreement of -2.5 to 2.79 at 95% CI. The device exhibits an accuracy of 96.85% and acceptable reproducibility, with CV ranging from 0.8 to 7.5%. An integrated detection cum readout guiding pattern may allow this device to be suitable for simultaneous quantitative and qualitative estimation and to be employed in both developed and resource-limited clinical settings for Hct measurement in routine checkups and regular monitoring during critical care, as well as in the initial screening of large anemic populations.


Assuntos
Teste em Amostras de Sangue Seco , Smartphone , Humanos , Hematócrito , Reprodutibilidade dos Testes , Algoritmos
5.
Clin Chim Acta ; 547: 117418, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37276944

RESUMO

BACKGROUND: Dried blood spot (DBS) size and quality affect newborn screening (NBS) test results. Visual assessment of DBS quality is subjective. METHODS: We developed and validated a computer vision (CV) algorithm to measure DBS diameter and identify incorrectly applied blood in images from the Panthera DBS puncher. We used CV to assess historical trends in DBS quality and correlate DBS diameter to NBS analyte concentrations in 130,620 specimens. RESULTS: CV estimates of DBS diameter were precise (percentage coefficient of variation < 1.3%) and demonstrated excellent agreement with digital calipers with a mean (standard deviation) difference of 0.23 mm (0.18 mm). An optimised logistic regression model showed a sensitivity of 94.3% and specificity of 96.8% for detecting incorrectly applied blood. In a validation set of images (n = 40), CV agreed with an expert panel in all acceptable specimens and identified all specimens rejected by the expert panel due to incorrect blood application or DBS diameter > 14 mm. CV identified a reduction in unsuitable NBS specimens from 25.5% in 2015 to 2% in 2021. Each mm decrease in DBS diameter decreased analyte concentrations by up to 4.3%. CONCLUSIONS: CV can aid assessment of DBS size and quality to harmonize specimen rejection both within and between laboratories.


Assuntos
Teste em Amostras de Sangue Seco , Triagem Neonatal , Recém-Nascido , Humanos , Teste em Amostras de Sangue Seco/métodos , Triagem Neonatal/métodos , Coleta de Amostras Sanguíneas/métodos , Algoritmos , Laboratórios
6.
Ther Drug Monit ; 45(4): 463-478, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728554

RESUMO

BACKGROUND: Volumetric absorptive microsampling (VAMS) is an emerging technique that may support multisample collection to enhance therapeutic drug monitoring in solid organ transplantation. This review aimed to assess whether tacrolimus and mycophenolic acid can be reliably assayed using VAMS and to identify knowledge gaps by providing granularity to existing analytical methods and clinical applications. METHODS: A systematic literature search was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The PubMed, Embase, and Scopus databases were accessed for records from January 2014 to April 2022 to identify scientific reports on the clinical validation of VAMS for monitoring tacrolimus and mycophenolic acid concentrations. Data on the study population, sample sources, analytical methods, and comparison results were compiled. RESULTS: Data from 12 studies were collected, including 9 studies pertaining to tacrolimus and 3 studies on the concurrent analysis of tacrolimus and mycophenolic acid. An additional 14 studies that provided information relevant to the secondary objectives (analytical validation and clinical application) were also included. The results of the clinical validation studies generally met the method agreement requirements described by regulatory agencies, but in many cases, it was essential to apply correction factors. CONCLUSIONSS: Current evidence suggests that the existing analytical methods that use VAMS require additional optimization steps for the analysis of tacrolimus and mycophenolic acid. The recommendations put forth in this review can help guide future studies in achieving the goal of improving the care of transplant recipients by simplifying multisample collection for the dose optimization of these drugs.


Assuntos
Transplante de Órgãos , Tacrolimo , Humanos , Ácido Micofenólico , Monitoramento de Medicamentos/métodos , Espectrometria de Massas em Tandem/métodos , Coleta de Amostras Sanguíneas/métodos , Teste em Amostras de Sangue Seco
7.
J Pharm Biomed Anal ; 228: 115311, 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-36841066

RESUMO

Volumetric absorptive microsampling (VAMS) has emerged as a minimally invasive alternative to conventional sampling. However, the applicability of VAMS must be investigated clinically. Therefore, the feasibility of at-home sampling was investigated for the kinase inhibitors nilotinib, cabozantinib, dabrafenib, trametinib and ruxolitinib and evaluated regarding the acceptance of at-home microsampling, sample quality of at-home VAMS and incurred sample stability. In addition, clinical validation including three different approaches for serum level predictions was performed. For this purpose, VAMS and reference serum samples were collected simultaneously. Conversion of VAMS to serum concentration was based either on a linear regression model, a hematocrit-dependent formula, or using a correction factor. During the study period 591 VAMS were collected from a total of 59 patients. The percentage of patients who agreed to perform VAMS at home ranged from 50.0 % to 84.6 % depending on the compound. 93.1 % of at-home VAMS were collected correctly. Regarding the drug stability in dried capillary blood, no stability issues were detected between on-site and at-home VAMS. Linear regression showed a strong correlation between VAMS and reference serum concentrations for nilotinib, cabozantinib, dabrafenib and ruxolitinib (r 0.9427 - 0.9674) and a moderate correlation for trametinib (r 0.5811). For clinical validation, the acceptance criteria were met for all three approaches for three of the five kinase inhibitors. Predictive performance was not improved by using individual hematocrit instead of population hematocrit and was largely independent of conversion model. In conclusion, VAMS at-home has been shown to be feasible for use in routine clinical care and serum values could be predicted based on the measured VAMS concentration for nilotinib, cabozantinib, and dabrafenib.


Assuntos
Coleta de Amostras Sanguíneas , Teste em Amostras de Sangue Seco , Humanos , Estudos de Viabilidade
8.
Int J Infect Dis ; 125: 51-57, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36241163

RESUMO

OBJECTIVES: This study aimed to determine the agreement between a rapid diagnostic test (RDT) and a dried blood spot (DBS)-based electrochemiluminescence immunoassay (ECLIA) of hepatitis B surface antigen and to compare the costs of conducting serosurveys using RDTs and DBS in a field setting. METHODS: A serosurvey was conducted in the South Central Coast region of Vietnam in May 2019. Participants aged 1-39 years were recruited using a four-stage random sampling method and tested for hepatitis B surface antigen using an RDT kit (Alere Determine) and a DBS-based ECLIA. The agreement between the RDT and the DBS-based ECLIA was assessed using cross-tabulation and Cohen kappa. Cost data were categorized by input (personnel, transportation, field consumables, laboratory consumables, and capital item/overhead) and survey phase (survey preparation, data/biospecimen collection, laboratory testing, and coordination). RESULTS: A total of 2072 participants were analyzed. There was a 99% agreement between the RDT and the DBS-based ECLIA results, with a Cohen kappa of 0.9. The estimated cost of conducting a serosurvey by DBS was UD $75,291, whereas RDT was $53,182. CONCLUSION: RDTs and DBS-based ECLIA provide test results with high agreements. RDTs are a better option in terms of cost, whereas the DBS-based ECLIA may be useful when evaluating multiple infectious diseases.


Assuntos
Antígenos de Superfície da Hepatite B , Hepatite B , Testes de Diagnóstico Rápido , Humanos , Teste em Amostras de Sangue Seco/métodos , Imunoensaio/métodos , Sensibilidade e Especificidade , Vietnã/epidemiologia , Hepatite B/diagnóstico
9.
Anal Chem ; 94(28): 10127-10134, 2022 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35802862

RESUMO

To achieve the measurement reliability of amino acids used as diagnostic markers in clinical fields, establishing a reference measurement system is required, in which certified reference materials (CRMs) are an essential step in the hierarchy of measurement traceability. This study describes the development of dried blood spot (DBS) CRMs for amino acid analysis with complete measurement traceability to the International System of Units (SI). Six essential amino acids─proline, valine, isoleucine, leucine, phenylalanine, and tyrosine─were analyzed using isotope-dilution liquid chromatography-mass spectrometry (ID-MS). For minimizing measurement bias and uncertainty overestimation, whole spots with 50 µL of whole blood were adopted in the certification. The between-spot homogeneities by whole spot sampling were lower than 2.1%. The relative expanded uncertainties of the six amino acids in the developed DBS CRMs were lower than 5.7% at 95% confidence. The certified values are traceable to SI through both gravimetric preparation and the primary method in certification, ID-MS. Comparison among DBS testing laboratories revealed discrepancies between the whole spot and disc sampling methods. The actual sampling volume was accurately estimated by weighing, which revealed the possibility of underestimation in routine DBS testing. The candidate CRMs can support the standardization of DBS testing for amino acids through the qualification and validation of many kinds of measurement procedures to compensate the measurement bias caused by matrix-specific sampling error.


Assuntos
Aminoácidos , Teste em Amostras de Sangue Seco , Aminoácidos/análise , Certificação , Cromatografia Líquida/métodos , Padrões de Referência , Reprodutibilidade dos Testes
10.
PLoS One ; 16(8): e0255237, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34407110

RESUMO

BACKGROUND: Telomere length (TL) in peripheral blood mononuclear cells (PBMC) from fresh venous blood is increasingly used to estimate molecular impacts of accumulated social adversity on population health. Sometimes, TL extracted from saliva or dried blood spots (DBS) are substituted as less invasive and more scalable specimen collection methods; yet, are they interchangeable with fresh blood? Studies find TL is correlated across tissues, but have not addressed the critical question for social epidemiological applications: Do different specimen types show the same association between TL and social constructs? METHODS: We integrate expertise in social epidemiology, molecular biology, and the statistical impact of measurement error on parameter estimates. Recruiting a diverse sample of 132 Metro-Detroit women, we measure TL for each woman from fresh blood PBMC, DBS, and saliva. Using regression methods, we estimate associations between social characteristics and TL, comparing estimates across specimen types for each woman. RESULTS: Associations between TL and social characteristics vary by specimen type collected from the same woman, sometimes qualitatively altering estimates of the magnitude or direction of a theorized relationship. Being Black is associated with shorter TL in PBMC, but longer TL in saliva or DBS. Education is positively associated with TL in fresh blood, but negatively associated with TL using DBS. CONCLUSION: Findings raise concerns about the use of TL measures derived from different tissues in social epidemiological research. Investigators need to consider the possibility that associations between social variables and TL may be systematically related to specimen type, rather than be valid indicators of socially-patterned biopsychosocial processes.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Equidade em Saúde , Pesquisa , Saliva/metabolismo , Homeostase do Telômero , Adulto , Humanos , Leucócitos Mononucleares/metabolismo , Michigan , Pessoa de Meia-Idade
11.
Nat Commun ; 12(1): 3695, 2021 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-34140485

RESUMO

Serological testing is essential to curb the consequences of the COVID-19 pandemic. However, most assays are still limited to single analytes and samples collected within healthcare. Thus, we establish a multianalyte and multiplexed approach to reliably profile IgG and IgM levels against several versions of SARS-CoV-2 proteins (S, RBD, N) in home-sampled dried blood spots (DBS). We analyse DBS collected during spring of 2020 from 878 random and undiagnosed individuals from the population in Stockholm, Sweden, and use classification approaches to estimate an accumulated seroprevalence of 12.5% (95% CI: 10.3%-14.7%). This includes 5.4% of the samples being IgG+IgM+ against several SARS-CoV-2 proteins, as well as 2.1% being IgG-IgM+ and 5.0% being IgG+IgM- for the virus' S protein. Subjects classified as IgG+ for several SARS-CoV-2 proteins report influenza-like symptoms more frequently than those being IgG+ for only the S protein (OR = 6.1; p < 0.001). Among all seropositive cases, 30% are asymptomatic. Our strategy enables an accurate individual-level and multiplexed assessment of antibodies in home-sampled blood, assisting our understanding about the undiagnosed seroprevalence and diversity of the immune response against the coronavirus.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Teste Sorológico para COVID-19/métodos , COVID-19/imunologia , Imunidade Humoral , Adulto , Idoso , Anticorpos Antivirais/imunologia , COVID-19/etiologia , Teste em Amostras de Sangue Seco , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/imunologia , Suécia , Adulto Jovem
12.
Proc Natl Acad Sci U S A ; 118(18)2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33945500

RESUMO

Novel technologies are needed to facilitate large-scale detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific antibodies in human blood samples. Such technologies are essential to support seroprevalence studies and vaccine clinical trials, and to monitor quality and duration of immunity. We developed a microfluidic nanoimmunoassay (NIA) for the detection of anti-SARS-CoV-2 IgG antibodies in 1,024 samples per device. The method achieved a specificity of 100% and a sensitivity of 98% based on the analysis of 289 human serum samples. To eliminate the need for venipuncture, we developed low-cost, ultralow-volume whole blood sampling methods based on two commercial devices and repurposed a blood glucose test strip. The glucose test strip permits the collection, shipment, and analysis of 0.6 µL of whole blood easily obtainable from a simple finger prick. The NIA platform achieves high throughput, high sensitivity, and specificity based on the analysis of 289 human serum samples, and negligible reagent consumption. We furthermore demonstrate the possibility to combine NIA with decentralized and simple approaches to blood sample collection. We expect this technology to be applicable to current and future SARS-CoV-2 related serological studies and to protein biomarker analysis in general.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , COVID-19/sangue , Teste Sorológico para COVID-19/economia , Teste em Amostras de Sangue Seco , Ensaios de Triagem em Larga Escala/economia , Humanos , Imunoensaio/economia , Imunoglobulina G/sangue , Técnicas Analíticas Microfluídicas/economia , Reprodutibilidade dos Testes , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Manejo de Espécimes
13.
PLoS One ; 16(5): e0251115, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33989336

RESUMO

This study evaluated the adherence to prescribed cardiovascular therapy medications among cardiovascular disease patients attending clinics in Misan, Amara, Iraq. Mixed methods were used to assess medication adherence comprising the Arabic version of the eight-item Morisky Medication Adherence Scale (MMAS-8) and determination of drug concentrations in patient dried blood spot (DBS) samples by liquid chromatography-high resolution mass spectrometry. Three hundred and three Iraqi patients (median age 53 years, 50.5% female) who had been taking one or more of the nine commonly prescribed cardiovascular medications (amlodipine, atenolol, atorvastatin, bisoprolol, diltiazem, lisinopril, losartan, simvastatin and valsartan) for at least six months were enrolled. For each patient MMAS-8 scores were determined alongside drug concentrations in their dried blood spot samples. Results from the standardized questionnaire showed that adherence was 81.8% in comparison with 50.8% obtained using the laboratory-based microsample analysis. The agreement between the indirect (MMAS-8) and direct (DBS analysis) assessment approaches to assessing medication adherence showed significantly poor agreement (kappa = 0.28, P = 0.001). The indirect and direct assessment approaches showed no significant correlation between nonadherence to prescribed cardiovascular pharmacotherapy and age and gender, but were significantly associated with the number of medications in the patient's treatment regimen (MMAS-8: Odds Ratio (OR) 1.947, 95% CI, P = 0.001; DBS analysis: OR 2.164, 95% CI, P = 0.001). The MMAS-8 results highlighted reasons for nonadherence to prescribed cardiovascular pharmacotherapy in this patient population whilst the objective DBS analysis approach gave valuable information about nonadherence to each medication in the patient's treatment regimen. DBS sampling, due its minimally invasive nature, convenience and ease of transport is a useful alternative matrix to monitor adherence objectively in Iraq to cardiovascular pharmacotherapy. This information combined with MMAS-8 can provide clinicians with an evidence-based novel approach to implement intervention strategies to optimise and personalise cardiovascular pharmacotherapy in the Iraqi population and thereby improve patient health outcomes.


Assuntos
Fármacos Cardiovasculares/sangue , Fármacos Cardiovasculares/uso terapêutico , Doenças Cardiovasculares/tratamento farmacológico , Adesão à Medicação/estatística & dados numéricos , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Sistema Cardiovascular/patologia , Teste em Amostras de Sangue Seco/métodos , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Iraque , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
14.
Anal Chem ; 93(4): 2660-2668, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33405897

RESUMO

Many populations in low- and middle income countries are at a higher risk of thiamine deficiency, mainly due to the lack of dietary diversification and their reliance on staple crops low in thiamine content, such as polished rice. Unfortunately, symptoms of thiamine deficiency are variable and clinical determination of thiamine status is essential for early diagnosis. Currently, the diagnosis of thiamine deficiency in remote regions is hampered due to several drawbacks related to venous blood collection, for example, cold chain transport. Therefore, we here describe the first liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of thiamine diphosphate (TDP) in dried blood, using volumetric absorptive microsampling (VAMS). Moreover, by setting up an additional method in liquid blood, the results in VAMS samples could be compared to liquid blood samples. Both methods, employing a simple one-step extraction and fast (2 min) chromatography, were fully validated based on international guidelines. Accuracy (% bias) was below 6.5% for all QC levels. The total imprecision (% CV) was below 13% for both QCs and native blood samples. The recovery of the VAMS samples was not impacted by the hematocrit, within the hematocrit range of 0.20-0.60. Additionally, we showed improved TDP stability in dried blood compared to liquid blood. VAMS samples were stable for 1 week at 60 °C or at high humidity (80%) and for at least 1 month at room temperature. Finally, we demonstrated the commutability of commercial calibrators with authentic blood samples. The validity and applicability of both methods were demonstrated via their successful application on blood samples from healthy volunteers.


Assuntos
Cromatografia Líquida/métodos , Teste em Amostras de Sangue Seco , Espectrometria de Massas em Tandem/métodos , Tiamina/sangue , Humanos , Reprodutibilidade dos Testes
15.
Environ Res ; 198: 110444, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33186577

RESUMO

Lead (Pb) exposure is often determined through the analysis of whole blood though venipuncture poses ethical, economic, and logistical barriers. Dried Blood Spots (DBS) may help overcome such barriers though past studies measuring Pb in DBS have been challenged with quality control, small sample volumes, and other issues. Total Reflection X-Ray Fluorescence (TXRF) may help address some of these challenges but has yet to be used to measure Pb in DBS. As such, the aim of the current study was to develop, validate, and apply a method to analyze Pb in DBS samples using TXRF for use in human biomonitoring studies. First, we developed a novel method (tested a range of parameters), and then used blood reference materials to validate the method against performance criteria listed in ICH Q2A and Q2B and the European Bioanalysis Forum. Finally, we applied the method to two populations who exemplify divergent conditions (41 university members with relatively low Pb exposures sampled in a clinical environment; 40 electronic waste workers with relatively high Pb exposures sampled in a contaminated field setting). The limits of detection and quantification of the method were 0.28 and 0.69 µg/dL, respectively. The overall precision and accuracy of the method were 15% and 111%, respectively. The mean (±SD) DBS Pb levels by TXRF in the university members and e-waste workers were 0.78 (±0.46) and 3.78 (±3.01) µg/dL, respectively, and these were not different from Pb measures in venous whole blood using ICP-MS. Bland-Altman plot analyses indicated good agreement between DBS Pb measures by TXRF versus whole blood Pb measures by ICP-MS in both groups. By combining data from the two population groups, there was no significant constant bias (intercept of 0.02 µg/dL) or proportional bias (slope was -0.02) between the two measures, and the lower and upper LoA were -0.86 and 0.91 µg/dL, respectively, with a LoA range of 1.77 µg/dL. These results demonstrate that TXRF-based analysis of Pb content in DBS is a good alternative to the gold standard (i.e., ICP-MS analysis of whole blood), and helps overcome some of the challenges associated with current methods.


Assuntos
Teste em Amostras de Sangue Seco , Chumbo , Monitoramento Biológico , Humanos , Raios X
16.
Br J Haematol ; 192(1): 28-32, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32617974

RESUMO

Most cancer cases occur in areas of low resources. The diagnosis, treatment and monitoring of cancers is especially challenging in these locations. Unique partnerships exist between non-profit organisations and pharmaceutical companies to provide free drugs to CML patients throughout the world if the diagnosis can be rigorously and unambiguously established. But there lies the rub: How do you perform molecular diagnostics in areas where even electricity is unreliable? Here we describe the evolution of testing patients from low resource areas, which, when merged with a remarkable effort to bring tyrosine kinase inhibitors to patients across the globe, have led to survival outcomes similar to cases in industrialised countries.


Assuntos
Leucemia Mielogênica Crônica BCR-ABL Positiva/diagnóstico , Antineoplásicos/uso terapêutico , Países em Desenvolvimento , Teste em Amostras de Sangue Seco/economia , Proteínas de Fusão bcr-abl/genética , Humanos , Mesilato de Imatinib/uso terapêutico , Leucemia Mielogênica Crônica BCR-ABL Positiva/sangue , Leucemia Mielogênica Crônica BCR-ABL Positiva/tratamento farmacológico , Leucemia Mielogênica Crônica BCR-ABL Positiva/genética , Técnicas de Diagnóstico Molecular/economia , Reação em Cadeia da Polimerase em Tempo Real/economia , Resultado do Tratamento
17.
Sci Rep ; 10(1): 21089, 2020 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-33273485

RESUMO

Rheumatoid arthritis (RA) is characterised by painful, stiff and swollen joints. RA features sporadic 'flares' or inflammatory episodes-mostly occurring outside clinics-where symptoms worsen and plasma C-reactive protein (CRP) becomes elevated. Poor control of inflammation results in higher rates of irreversible joint damage, increased disability, and poorer quality of life. Flares need to be accurately identified and managed. A method comparison study was designed to assess agreement between CRP values obtained by dried blood spot (DBS) versus conventional venepuncture sampling. The ability of a weekly DBS sampling and CRP test regime to detect flare outside the clinic was also assessed. Matched venepuncture and finger lancet DBS samples were collected from n = 100 RA patients with active disease at baseline and 6 weeks (NCT02809547). A subset of n = 30 RA patients submitted weekly DBS samples over the study period. Patient demographics, including self-reported flares were recorded. DBS sample CRP measurements were made by enzyme-linked immunosorbent assay, and venepuncture samples by a reference immunoturbometric assay. Data was compared between sample types by Bland-Altman and weighted Deming regression analyses. Flare detection sensitivity and specificity were compared between 'minimal' baseline and 6 week sample CRP data and the 'continuous' weekly CRP data. Baseline DBS ELISA assay CRP measures yielded a mean positive bias of 2.693 ± 8.640 (95% limits of agreement - 14.24 to 19.63%), when compared to reference assay data. Deming regression revealed good agreement between the DBS ELISA method and reference assay data, with baseline data slope of 0.978 and intercept -0.153. The specificity of 'continuous' area under the curve (AUC) CRP data (72.7%) to identify flares, was greater than 'minimal' AUC CRP data (54.5%). This study indicates reasonable agreement between DBS and the reference method, especially at low to mid-range CRP values. Importantly, longitudinal CRP measurement in RA patients helps to clearly identify flare and thus could assist in remote monitoring strategies and may facilitate timely therapeutic intervention.Trial registration: The Remote Arthritis Disease Activity MonitoR (RADAR) study was registered on 22/06/2016 at ClinicalTrials.gov Identifier: NCT02809547. https://clinicaltrials.gov/ct2/show/NCT02809547 .


Assuntos
Artrite Reumatoide/sangue , Proteína C-Reativa/análise , Teste em Amostras de Sangue Seco/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/patologia , Biomarcadores/sangue , Teste em Amostras de Sangue Seco/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
18.
Cells ; 9(10)2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33076340

RESUMO

Inborn errors of metabolism and diabetes share common derangements in analytes of metabolic networks that are tested for in newborn screening, usually performed 48-72 h after birth. There is limited research examining the metabolic imprint of diabetes on newborn screening results. This paper aims to demonstrate the links between diabetes, biochemical genetics and newborn screening in investigating disease pathophysiology in diabetes, provide possible reasons for the lack of research in diabetes in newborn screening and offer recommendations on potential research areas. We performed a systematic search of the available literature from 1 April 1998 to 31 December 2018 involving newborn screening and diabetes using OVID, MEDLINE, Cochrane and the PROSPERO register, utilizing a modified extraction tool adapted from Cochrane. Eight studies were included after screening 1312 records. Five studies reanalyzed dried blood spots (DBS) on filter paper cards, and three studies utilized pre-existing results. The results of these studies and how they relate to cord blood studies, the use of cord blood versus newborn screening dried blood spots as a sample and considerations on newborn screening and diabetes research is further discussed. The timing of sampling of newborn screening allows insight into neonatal physiology in a catabolic state with minimal maternal and placental influence. This, combined with the wide coverage of newborn screening worldwide, may aid in our understanding of the origins of diabetes.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Diabetes Mellitus/diagnóstico , Triagem Neonatal/métodos , Diabetes Mellitus/congênito , Teste em Amostras de Sangue Seco , Feminino , Sangue Fetal , Humanos , Recém-Nascido , Gravidez , Manejo de Espécimes , Avaliação da Tecnologia Biomédica
19.
Emerg Infect Dis ; 26(12): 2970-2973, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32969788

RESUMO

Dried blood spot (DBS) samples can be used for the detection of severe acute respiratory syndrome coronavirus 2 spike antibodies. DBS sampling is comparable to matched serum samples with a relative 98.1% sensitivity and 100% specificity. Thus, DBS sampling offers an alternative for population-wide serologic testing in the coronavirus pandemic.


Assuntos
COVID-19/diagnóstico , Teste em Amostras de Sangue Seco/métodos , Anticorpos Antivirais/imunologia , Teste Sorológico para COVID-19/métodos , Estudos de Casos e Controles , Teste em Amostras de Sangue Seco/economia , Humanos , Valor Preditivo dos Testes , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/isolamento & purificação
20.
Rev Mal Respir ; 37(8): 633-643, 2020 Oct.
Artigo em Francês | MEDLINE | ID: mdl-32859429

RESUMO

INTRODUCTION: Alpha1-antitrypsin deficiency is a predisposing factor for pulmonary disease and under-diagnosis is a significant problem. The results of a targeted screening in patients with respiratory symptoms possibly indicative of severe deficiency are reported here. METHODS: Data were collected from March 2016 to October 2017 on patients who had a capillary blood sample collected during a consultation with a pulmonologist and sent to the laboratory for processing to determine alpha1-antitrypsin concentration, phenotype and possibly genotype. RESULTS: In 20 months, 3728 test kits were requested by 566 pulmonologists and 718 (19 %) specimens sent: among these, 708 were analyzable and 613 were accompanied by clinical information. Of the 708 samples, 70 % had no phenotype associated with quantitative alpha1- antitrypsin deficiency, 7 % had a phenotype associated with a severe deficiency and 23 % had a phenotype associated with an intermediate deficiency. One hundred and eight patients carried at least one PI*Z allele which is considered to be a risk factor for liver disease. CONCLUSIONS: The results of this targeted screening program for alpha1- antitrypsin deficiency using a dried capillary blood sample reflect improvement in early diagnosis of this deficiency in lung disease with good adherence of the pulmonologists to this awareness campaign.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Programas de Rastreamento/métodos , Deficiência de alfa 1-Antitripsina/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bronquiectasia/sangue , Bronquiectasia/diagnóstico , Bronquiectasia/genética , Criança , Análise Mutacional de DNA/métodos , Análise Mutacional de DNA/normas , Teste em Amostras de Sangue Seco/normas , Feminino , França/epidemiologia , Predisposição Genética para Doença , Genótipo , Humanos , Estudos Longitudinais , Masculino , Programas de Rastreamento/organização & administração , Pessoa de Meia-Idade , Fenótipo , Avaliação de Programas e Projetos de Saúde , Doença Pulmonar Obstrutiva Crônica/sangue , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/genética , Enfisema Pulmonar/sangue , Enfisema Pulmonar/diagnóstico , Enfisema Pulmonar/genética , Adulto Jovem , alfa 1-Antitripsina/análise , alfa 1-Antitripsina/genética , Deficiência de alfa 1-Antitripsina/sangue , Deficiência de alfa 1-Antitripsina/epidemiologia , Deficiência de alfa 1-Antitripsina/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA