Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
AAPS J ; 26(4): 75, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38955903

RESUMO

Blood microsampling has increasingly attracted interest in the past decades as a more patient-centric sampling approach, offering the possibility to collect a minimal volume of blood following a finger or arm prick at home. In addition to conventional dried blood spots (DBS), many different devices allowing self-sampling of blood have become available. Obviously, the success of home-sampling can only be assured when (inexperienced) users collect samples of good quality. Therefore, the feasibility of six different microsampling devices to collect capillary blood by inexperienced adolescents at home was evaluated. Participants (n = 95) were randomly assigned to collect blood (dried or liquid) at different time points using four of six different self-sampling devices (i.e., DBS, Mitra volumetric absorptive microsampling (VAMS), Capitainer B, Tasso M20, Minicollect tube and Tasso+ serum separator tube (SST)). The quality of the samples was visually inspected and analytically determined. Moreover, the participants' satisfaction was assessed via questionnaires. Although a majority succeeded based on the visual inspection, the success rate differed largely between the different devices. In general, the lowest success rate was obtained for the Minicollect tubes, although there is an opportunity and need for improvement for the other self-sampling devices as well. Hence, this also emphasizes the importance to assess the quality of samples collected by the target population prior to study initiation. In addition, visual classification by a trained individual was confirmed based on assessment of the analytical variability between replicates. Finally, self-sampling at home was overall (very) positively received by the participants.


Assuntos
Coleta de Amostras Sanguíneas , Estudos de Viabilidade , Humanos , Adolescente , Feminino , Masculino , Coleta de Amostras Sanguíneas/métodos , Autocuidado/métodos , Teste em Amostras de Sangue Seco/métodos , Satisfação do Paciente
2.
Clin Lab ; 70(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747911

RESUMO

BACKGROUND: This study aims to evaluate the ability of laboratories to perform spinal muscular atrophy (SMA) genetic testing in newborns based on dried blood spot (DBS) samples, and to provide reference data and advance preparation for establishing the pilot external quality assessment (EQA) scheme for SMA genetic testing of newborns in China. METHODS: The pilot EQA scheme contents and evaluation principles of this project were designed by National Center for Clinical Laboratories (NCCL), National Health Commission. Two surveys were carried out in 2022, and 5 batches of blood spots were submitted to the participating laboratory each time. All participating laboratories conducted testing upon receiving samples, and test results were submitted to NCCL within the specified date. RESULTS: The return rates were 75.0% (21/28) and 95.2% (20/21) in the first and second surveys, respectively. The total return rate of the two examinations was 83.7% (41/49). Nineteen laboratories (19/21, 90.5%) had a full score passing on the first survey, while in the second survey twenty laboratories (20/20, 100%) scored full. CONCLUSIONS: This pilot EQA survey provides a preliminary understanding of the capability of SMA genetic testing for newborns across laboratories in China. A few laboratories had technical or operational problems in testing. It is, therefore, of importance to strengthen laboratory management and to improve testing capacity for the establishment of a national EQA scheme for newborn SMA genetic testing.


Assuntos
Testes Genéticos , Atrofia Muscular Espinal , Triagem Neonatal , Humanos , Recém-Nascido , Atrofia Muscular Espinal/diagnóstico , Atrofia Muscular Espinal/genética , Projetos Piloto , Testes Genéticos/normas , Testes Genéticos/métodos , Triagem Neonatal/normas , Triagem Neonatal/métodos , China , Teste em Amostras de Sangue Seco/normas , Teste em Amostras de Sangue Seco/métodos , Garantia da Qualidade dos Cuidados de Saúde , Laboratórios Clínicos/normas , Proteína 1 de Sobrevivência do Neurônio Motor/genética
3.
J Appl Lab Med ; 9(3): 512-525, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38384160

RESUMO

BACKGROUND: In addition to newborn screening, dried blood spots (DBSs) are used for a wide variety of analytes for clinical, epidemiological, and research purposes. Guidelines on DBS collection, storage, and transport are available, but it is suggested that each laboratory should establish its own acceptance criteria. METHODS: An optical scanning device was developed to assess the quality of DBSs received in the newborn screening laboratory from 11 maternity wards between 2013 and 2018. The algorithm was adjusted to agree with the visual examination consensus of experienced laboratory personnel. Once validated, the algorithm was used to categorize DBS specimens as either proper or improper. Improper DBS specimens were further divided based on 4 types of specimen defects. RESULTS: In total, 27 301 DBSs were analyzed. Compared with an annual DBS rejection rate of about 1%, automated scanning rejected 26.96% of the specimens as having at least one defect. The most common specimen defect was multi-spotting (ragged DBS, 19.13%). Among maternity wards, improper specimen rates varied greatly between 5.70% and 49.92%. CONCLUSIONS: Improper specimen rates, as well as the dominant type of defect(s), are mainly institution-dependent, with various maternity wards consistently showing specific patterns of both parameters over time. Although validated in agreement with experienced laboratory personnel consensus, automated analysis rejects significantly more specimens. While continuous staff training, specimen quality monitoring, and problem-reporting to maternities is recommended, a thorough quality assessment strategy should also be implemented by every newborn screening laboratory. An important role in this regard may be played by automation in the form of optical scanning devices.


Assuntos
Algoritmos , Teste em Amostras de Sangue Seco , Triagem Neonatal , Humanos , Triagem Neonatal/métodos , Triagem Neonatal/normas , Recém-Nascido , Teste em Amostras de Sangue Seco/métodos , Teste em Amostras de Sangue Seco/normas , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas
4.
Sci Rep ; 13(1): 13008, 2023 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-37563249

RESUMO

Dried blood spot (DBS) sample collection has been suggested as a less invasive, cheaper and more convenient alternative to venepuncture, which requires trained personnel, making it a potentially viable approach for self-collection of blood on a large scale. We examine whether participants in a longitudinal survey were willing to provide a DBS sample in different interview settings, and how resulting cardiovascular risk biomarkers compared with those from venous blood to calculate clinical risk. Participants of the Understanding Society Innovation Panel, a representative sample of UK households, were randomly assigned to three modes of interview. Most participants (84%) were interviewed in their allocated mode. Participants (n = 2162) were interviewed by a nurse who collected both a blood sample by venepuncture and a DBS card ('nurse collection') or participants were seen by an interviewer or took part in the survey online to self-collect a DBS card ('self-collection'). All DBS cards were returned in the post after the sample had dried. Lipids (total cholesterol, HDL-cholesterol, triglycerides), HbA1c and C-reactive protein were measured in venous and DBS samples and equivalence was calculated. The resultant values were used to confirm equivalent prevalence of risk of cardiovascular disease in each type of blood sample by mode of participation. Of participants interviewed by a nurse 69% consented to venous blood sample and 74% to a DBS sample, while in the self-collection modes, 35% consented to DBS collection. Demographic characteristics of participants in self-collection mode was not different to those in nurse collection mode. The percentage of participants with clinically raised biomarkers did not significantly differ between type of blood collection (for example, 62% had high cholesterol (> 5 mmol/l) measured by venepuncture and 67% had high cholesterol within the self-collected DBS sample (p = 0.13)). While self-collected DBS sampling had a lower response rate to DBS collected by a nurse, participation did not vary by key demographic characteristics. This study demonstrates that DBS collection is a feasible method of sample collection that can provide acceptable measures of clinically relevant biomarkers, enabling the calculation of population levels of cardiovascular disease risk.


Assuntos
Doenças Cardiovasculares , Humanos , Doenças Cardiovasculares/diagnóstico , Fatores de Risco , Teste em Amostras de Sangue Seco/métodos , Biomarcadores , HDL-Colesterol , Fatores de Risco de Doenças Cardíacas
5.
Clin Chim Acta ; 547: 117418, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37276944

RESUMO

BACKGROUND: Dried blood spot (DBS) size and quality affect newborn screening (NBS) test results. Visual assessment of DBS quality is subjective. METHODS: We developed and validated a computer vision (CV) algorithm to measure DBS diameter and identify incorrectly applied blood in images from the Panthera DBS puncher. We used CV to assess historical trends in DBS quality and correlate DBS diameter to NBS analyte concentrations in 130,620 specimens. RESULTS: CV estimates of DBS diameter were precise (percentage coefficient of variation < 1.3%) and demonstrated excellent agreement with digital calipers with a mean (standard deviation) difference of 0.23 mm (0.18 mm). An optimised logistic regression model showed a sensitivity of 94.3% and specificity of 96.8% for detecting incorrectly applied blood. In a validation set of images (n = 40), CV agreed with an expert panel in all acceptable specimens and identified all specimens rejected by the expert panel due to incorrect blood application or DBS diameter > 14 mm. CV identified a reduction in unsuitable NBS specimens from 25.5% in 2015 to 2% in 2021. Each mm decrease in DBS diameter decreased analyte concentrations by up to 4.3%. CONCLUSIONS: CV can aid assessment of DBS size and quality to harmonize specimen rejection both within and between laboratories.


Assuntos
Teste em Amostras de Sangue Seco , Triagem Neonatal , Recém-Nascido , Humanos , Teste em Amostras de Sangue Seco/métodos , Triagem Neonatal/métodos , Coleta de Amostras Sanguíneas/métodos , Algoritmos , Laboratórios
6.
Int J Infect Dis ; 125: 51-57, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36241163

RESUMO

OBJECTIVES: This study aimed to determine the agreement between a rapid diagnostic test (RDT) and a dried blood spot (DBS)-based electrochemiluminescence immunoassay (ECLIA) of hepatitis B surface antigen and to compare the costs of conducting serosurveys using RDTs and DBS in a field setting. METHODS: A serosurvey was conducted in the South Central Coast region of Vietnam in May 2019. Participants aged 1-39 years were recruited using a four-stage random sampling method and tested for hepatitis B surface antigen using an RDT kit (Alere Determine) and a DBS-based ECLIA. The agreement between the RDT and the DBS-based ECLIA was assessed using cross-tabulation and Cohen kappa. Cost data were categorized by input (personnel, transportation, field consumables, laboratory consumables, and capital item/overhead) and survey phase (survey preparation, data/biospecimen collection, laboratory testing, and coordination). RESULTS: A total of 2072 participants were analyzed. There was a 99% agreement between the RDT and the DBS-based ECLIA results, with a Cohen kappa of 0.9. The estimated cost of conducting a serosurvey by DBS was UD $75,291, whereas RDT was $53,182. CONCLUSION: RDTs and DBS-based ECLIA provide test results with high agreements. RDTs are a better option in terms of cost, whereas the DBS-based ECLIA may be useful when evaluating multiple infectious diseases.


Assuntos
Antígenos de Superfície da Hepatite B , Hepatite B , Testes de Diagnóstico Rápido , Humanos , Teste em Amostras de Sangue Seco/métodos , Imunoensaio/métodos , Sensibilidade e Especificidade , Vietnã/epidemiologia , Hepatite B/diagnóstico
7.
PLoS One ; 16(8): e0255237, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34407110

RESUMO

BACKGROUND: Telomere length (TL) in peripheral blood mononuclear cells (PBMC) from fresh venous blood is increasingly used to estimate molecular impacts of accumulated social adversity on population health. Sometimes, TL extracted from saliva or dried blood spots (DBS) are substituted as less invasive and more scalable specimen collection methods; yet, are they interchangeable with fresh blood? Studies find TL is correlated across tissues, but have not addressed the critical question for social epidemiological applications: Do different specimen types show the same association between TL and social constructs? METHODS: We integrate expertise in social epidemiology, molecular biology, and the statistical impact of measurement error on parameter estimates. Recruiting a diverse sample of 132 Metro-Detroit women, we measure TL for each woman from fresh blood PBMC, DBS, and saliva. Using regression methods, we estimate associations between social characteristics and TL, comparing estimates across specimen types for each woman. RESULTS: Associations between TL and social characteristics vary by specimen type collected from the same woman, sometimes qualitatively altering estimates of the magnitude or direction of a theorized relationship. Being Black is associated with shorter TL in PBMC, but longer TL in saliva or DBS. Education is positively associated with TL in fresh blood, but negatively associated with TL using DBS. CONCLUSION: Findings raise concerns about the use of TL measures derived from different tissues in social epidemiological research. Investigators need to consider the possibility that associations between social variables and TL may be systematically related to specimen type, rather than be valid indicators of socially-patterned biopsychosocial processes.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Equidade em Saúde , Pesquisa , Saliva/metabolismo , Homeostase do Telômero , Adulto , Humanos , Leucócitos Mononucleares/metabolismo , Michigan , Pessoa de Meia-Idade
8.
PLoS One ; 16(5): e0251115, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33989336

RESUMO

This study evaluated the adherence to prescribed cardiovascular therapy medications among cardiovascular disease patients attending clinics in Misan, Amara, Iraq. Mixed methods were used to assess medication adherence comprising the Arabic version of the eight-item Morisky Medication Adherence Scale (MMAS-8) and determination of drug concentrations in patient dried blood spot (DBS) samples by liquid chromatography-high resolution mass spectrometry. Three hundred and three Iraqi patients (median age 53 years, 50.5% female) who had been taking one or more of the nine commonly prescribed cardiovascular medications (amlodipine, atenolol, atorvastatin, bisoprolol, diltiazem, lisinopril, losartan, simvastatin and valsartan) for at least six months were enrolled. For each patient MMAS-8 scores were determined alongside drug concentrations in their dried blood spot samples. Results from the standardized questionnaire showed that adherence was 81.8% in comparison with 50.8% obtained using the laboratory-based microsample analysis. The agreement between the indirect (MMAS-8) and direct (DBS analysis) assessment approaches to assessing medication adherence showed significantly poor agreement (kappa = 0.28, P = 0.001). The indirect and direct assessment approaches showed no significant correlation between nonadherence to prescribed cardiovascular pharmacotherapy and age and gender, but were significantly associated with the number of medications in the patient's treatment regimen (MMAS-8: Odds Ratio (OR) 1.947, 95% CI, P = 0.001; DBS analysis: OR 2.164, 95% CI, P = 0.001). The MMAS-8 results highlighted reasons for nonadherence to prescribed cardiovascular pharmacotherapy in this patient population whilst the objective DBS analysis approach gave valuable information about nonadherence to each medication in the patient's treatment regimen. DBS sampling, due its minimally invasive nature, convenience and ease of transport is a useful alternative matrix to monitor adherence objectively in Iraq to cardiovascular pharmacotherapy. This information combined with MMAS-8 can provide clinicians with an evidence-based novel approach to implement intervention strategies to optimise and personalise cardiovascular pharmacotherapy in the Iraqi population and thereby improve patient health outcomes.


Assuntos
Fármacos Cardiovasculares/sangue , Fármacos Cardiovasculares/uso terapêutico , Doenças Cardiovasculares/tratamento farmacológico , Adesão à Medicação/estatística & dados numéricos , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Sistema Cardiovascular/patologia , Teste em Amostras de Sangue Seco/métodos , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Iraque , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários
9.
Sci Rep ; 10(1): 21089, 2020 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-33273485

RESUMO

Rheumatoid arthritis (RA) is characterised by painful, stiff and swollen joints. RA features sporadic 'flares' or inflammatory episodes-mostly occurring outside clinics-where symptoms worsen and plasma C-reactive protein (CRP) becomes elevated. Poor control of inflammation results in higher rates of irreversible joint damage, increased disability, and poorer quality of life. Flares need to be accurately identified and managed. A method comparison study was designed to assess agreement between CRP values obtained by dried blood spot (DBS) versus conventional venepuncture sampling. The ability of a weekly DBS sampling and CRP test regime to detect flare outside the clinic was also assessed. Matched venepuncture and finger lancet DBS samples were collected from n = 100 RA patients with active disease at baseline and 6 weeks (NCT02809547). A subset of n = 30 RA patients submitted weekly DBS samples over the study period. Patient demographics, including self-reported flares were recorded. DBS sample CRP measurements were made by enzyme-linked immunosorbent assay, and venepuncture samples by a reference immunoturbometric assay. Data was compared between sample types by Bland-Altman and weighted Deming regression analyses. Flare detection sensitivity and specificity were compared between 'minimal' baseline and 6 week sample CRP data and the 'continuous' weekly CRP data. Baseline DBS ELISA assay CRP measures yielded a mean positive bias of 2.693 ± 8.640 (95% limits of agreement - 14.24 to 19.63%), when compared to reference assay data. Deming regression revealed good agreement between the DBS ELISA method and reference assay data, with baseline data slope of 0.978 and intercept -0.153. The specificity of 'continuous' area under the curve (AUC) CRP data (72.7%) to identify flares, was greater than 'minimal' AUC CRP data (54.5%). This study indicates reasonable agreement between DBS and the reference method, especially at low to mid-range CRP values. Importantly, longitudinal CRP measurement in RA patients helps to clearly identify flare and thus could assist in remote monitoring strategies and may facilitate timely therapeutic intervention.Trial registration: The Remote Arthritis Disease Activity MonitoR (RADAR) study was registered on 22/06/2016 at ClinicalTrials.gov Identifier: NCT02809547. https://clinicaltrials.gov/ct2/show/NCT02809547 .


Assuntos
Artrite Reumatoide/sangue , Proteína C-Reativa/análise , Teste em Amostras de Sangue Seco/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/patologia , Biomarcadores/sangue , Teste em Amostras de Sangue Seco/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
10.
Emerg Infect Dis ; 26(12): 2970-2973, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32969788

RESUMO

Dried blood spot (DBS) samples can be used for the detection of severe acute respiratory syndrome coronavirus 2 spike antibodies. DBS sampling is comparable to matched serum samples with a relative 98.1% sensitivity and 100% specificity. Thus, DBS sampling offers an alternative for population-wide serologic testing in the coronavirus pandemic.


Assuntos
COVID-19/diagnóstico , Teste em Amostras de Sangue Seco/métodos , Anticorpos Antivirais/imunologia , Teste Sorológico para COVID-19/métodos , Estudos de Casos e Controles , Teste em Amostras de Sangue Seco/economia , Humanos , Valor Preditivo dos Testes , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/isolamento & purificação
11.
Rev Mal Respir ; 37(8): 633-643, 2020 Oct.
Artigo em Francês | MEDLINE | ID: mdl-32859429

RESUMO

INTRODUCTION: Alpha1-antitrypsin deficiency is a predisposing factor for pulmonary disease and under-diagnosis is a significant problem. The results of a targeted screening in patients with respiratory symptoms possibly indicative of severe deficiency are reported here. METHODS: Data were collected from March 2016 to October 2017 on patients who had a capillary blood sample collected during a consultation with a pulmonologist and sent to the laboratory for processing to determine alpha1-antitrypsin concentration, phenotype and possibly genotype. RESULTS: In 20 months, 3728 test kits were requested by 566 pulmonologists and 718 (19 %) specimens sent: among these, 708 were analyzable and 613 were accompanied by clinical information. Of the 708 samples, 70 % had no phenotype associated with quantitative alpha1- antitrypsin deficiency, 7 % had a phenotype associated with a severe deficiency and 23 % had a phenotype associated with an intermediate deficiency. One hundred and eight patients carried at least one PI*Z allele which is considered to be a risk factor for liver disease. CONCLUSIONS: The results of this targeted screening program for alpha1- antitrypsin deficiency using a dried capillary blood sample reflect improvement in early diagnosis of this deficiency in lung disease with good adherence of the pulmonologists to this awareness campaign.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Programas de Rastreamento/métodos , Deficiência de alfa 1-Antitripsina/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bronquiectasia/sangue , Bronquiectasia/diagnóstico , Bronquiectasia/genética , Criança , Análise Mutacional de DNA/métodos , Análise Mutacional de DNA/normas , Teste em Amostras de Sangue Seco/normas , Feminino , França/epidemiologia , Predisposição Genética para Doença , Genótipo , Humanos , Estudos Longitudinais , Masculino , Programas de Rastreamento/organização & administração , Pessoa de Meia-Idade , Fenótipo , Avaliação de Programas e Projetos de Saúde , Doença Pulmonar Obstrutiva Crônica/sangue , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/genética , Enfisema Pulmonar/sangue , Enfisema Pulmonar/diagnóstico , Enfisema Pulmonar/genética , Adulto Jovem , alfa 1-Antitripsina/análise , alfa 1-Antitripsina/genética , Deficiência de alfa 1-Antitripsina/sangue , Deficiência de alfa 1-Antitripsina/epidemiologia , Deficiência de alfa 1-Antitripsina/genética
12.
Biomed Chromatogr ; 34(10): e4917, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32543724

RESUMO

In the current study, two groups of rats (five per group) were administered a single oral dose of 500 mg/kg acetaminophen. For toxicokinetic assessment, the Group 1 animals were bled via conventional sparse (two animals/time point) sublingual vein bleeding (~0.5 ml) with anesthesia, while the Group 2 animals were bled via serial tail vein microsampling (~0.075 ml) without anesthesia. All collected blood was processed for plasma. Each Group 2 plasma sample (~30 µl) was divided into 'wet' and 'dried' (dried plasma spots). All plasma samples were analyzed by LC-MS/MS for acetaminophen and its major metabolites acetaminophen glucuronide and acetaminophen sulfate. In addition, plasma and urine samples were collected for analysis of corticosterone and creatinine to assess stress levels. Comparable plasma exposure to acetaminophen and its two metabolites was observed in the plasma obtained via conventional sparse sublingual vein bleeding and serial tail vein microsampling and between the 'wet' and 'dried' plasma obtained by the latter. Furthermore, comparable corticosterone levels or corticosterone/creatinine ratios between the two groups suggested that serial microsampling without anesthesia did not increase the levels of stress as compared with conventional sampling with anesthesia, confirming the utility of microsampling for plasma or dried plasma spots in rodent toxicokinetic assessment.


Assuntos
Acetaminofen , Coleta de Amostras Sanguíneas , Teste em Amostras de Sangue Seco/métodos , Cauda/irrigação sanguínea , Acetaminofen/sangue , Acetaminofen/química , Acetaminofen/toxicidade , Animais , Coleta de Amostras Sanguíneas/efeitos adversos , Coleta de Amostras Sanguíneas/métodos , Cromatografia Líquida , Corticosterona/sangue , Masculino , Modelos Químicos , Ratos , Estresse Psicológico , Espectrometria de Massas em Tandem , Toxicocinética
13.
Bioanalysis ; 12(6): 393-407, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32329378

RESUMO

Aim: Dried blood spot (DBS) is a sampling approach that offers several advantages over plasma and whole blood (WB) sampling, but several factors, such as hematocrit and temperature, can adversely affect quantitation. Methodology & results: In an open-label, three-way crossover study in healthy subjects, we explored the correlation between DBS, WB and plasma samples, and between DBS samples from finger-prick and venipuncture blood for measuring edoxaban and its metabolite M-4 using LC-MS/MS. The methods were validated comprehensively. The incurred sample reanalysis experiments demonstrated quantitation reproducibility in all three matrices. Overall, there was a good correlation (near perfect concordance for edoxaban) among plasma, WB and DBS measurements. M-4 concentrations in DBS and WB were lower than in plasma. Conclusion: These results indicate using DBS may be used as an alternative methodology to measure edoxaban pharmacokinetics.


Assuntos
Teste em Amostras de Sangue Seco/métodos , Inibidores do Fator Xa/uso terapêutico , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Estudos Cross-Over , Inibidores do Fator Xa/farmacologia , Voluntários Saudáveis , Humanos , Piridinas/farmacologia , Reprodutibilidade dos Testes , Tiazóis/farmacologia
14.
Clin Lab ; 66(3)2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32162878

RESUMO

BACKGROUND: Rapid and accurate diagnosis of mucopolysaccharidoses (MPS) is still a challenge due to poor access to screening and diagnostic methods and to their extensive clinical heterogeneity. The aim of this work is to perform laboratory biochemical testing for confirming the diagnosis of mucopolysaccharidosis (MPS) for the first time in Morocco. METHODS: Over a period of twelve months, 88 patients suspected of having Mucopolysaccharidosis (MPS) were referred to our laboratory. Quantitative and qualitative urine glycosaminoglycan (GAG) analyses were performed, and enzyme activity was assayed on dried blood spots (DBS) using fluorogenic substrates. Enzyme activity was measured as normal, low, or undetectable. RESULTS: Of the 88 patients studied, 26 were confirmed to have MPS; 19 MPS I (Hurler syndrome; OMIM #607014/Hurler-Scheie syndrome; OMIM #607015), 2 MPS II (Hunter syndrome; OMIM #309900), 2 MPS IIIA (Sanfilippo syndrome; OMIM #252900), 1 MPS IIIB (Sanfilippo syndrome; OMIM #252920) and 2 MPS VI (Maroteaux-Lamy syndrome; OMIM #253200). Parental consanguinity was present in 80.76% of cases. Qualitative urinary glycosaminoglycan (uGAGs) assays showed abnormal profiles in 31 cases, and further quantitative urinary GAG evaluation and Thin Layer Chromatography (TLC) provided important additional information about the likely MPS diagnosis. The final diagnosis was confirmed by specific enzyme activity analysis in the DBS samples. CONCLUSIONS: The present study shows that the adoption of combined urinary substrate analysis and enzyme assays using dried blood spots can facilitate such diagnosis, offer an important tool for an appropriate supporting care, and a specific therapy, when available.


Assuntos
Mucopolissacaridoses/diagnóstico , Mucopolissacaridoses/urina , Urinálise , Adolescente , Arilsulfatases/metabolismo , Arilsulfatases/urina , Criança , Pré-Escolar , Cromatografia em Camada Fina , Teste em Amostras de Sangue Seco/economia , Teste em Amostras de Sangue Seco/métodos , Feminino , Glicosaminoglicanos/análise , Glicosaminoglicanos/metabolismo , Humanos , Iduronidase/metabolismo , Iduronidase/urina , Masculino , Marrocos , Mucopolissacaridoses/enzimologia , Mucopolissacaridoses/metabolismo , Projetos Piloto , Urinálise/economia , Urinálise/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-31891859

RESUMO

This study aims to develop a liquid chromatography tandem-mass spectrometry (LC-MS/MS) method for vancomycin and creatinine measurement in dried blood spots (DBS) and to evaluate its clinical application. The analytes were extracted from DBS and analyzed by LC-MS/MS. Vancomycin and creatinine DBS and plasma concentrations were compared in 54 and 35 samples, respectively, from 29 patients. Accuracy was 94.4-102.6%, intra-assay precision was 2.1-5.6%, and inter-assay precision was 3.5-7.0%. Patients vancomycin plasma to DBS concentration ratios were highly variable (1.148-5.022), differently from creatinine (0.800-1.283). The assay has adequate analytical performance. Plasma concentrations can be satisfactorily predicted from DBS measurements for creatinine, but not for vancomycin, which limits its clinical application.


Assuntos
Creatinina/sangue , Teste em Amostras de Sangue Seco/métodos , Vancomicina/sangue , Adulto , Cromatografia Líquida/métodos , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/métodos
16.
J Viral Hepat ; 27(1): 36-44, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31520434

RESUMO

New antiviral drugs with high efficacy mean the hepatitis C virus (HCV) can now be eliminated. To achieve this, it is necessary to identify undiagnosed cases of HCV. However, the costs of testing should be considered when judging the overall cost-effectiveness of treatment. This study describes the cost-effectiveness of a community pharmacy testing service in a population of people at risk of HCV living on the Isle of Wight (United Kingdom). Dry blood spot testing was conducted in anyone with a known risk factor for HCV in 20 community pharmacies. The outcomes and costs were entered into a Markov model. Cost and health utilities from the model were used to calculate an incremental cost-effectiveness ratio (ICER). In 24 months, 186 tests were conducted, 13 were positive for HCV RNA and six of these (46%) received treatment during the follow-up period. All achieved a sustained virological response at 3 months. The overall cost of the testing and treatment intervention was £242 183, and the ICER for the service was £3689 per quality-adjusted life year (QALY) gained. If screening had been restricted to just people with a history of injecting drug use (PWID) the ICER would have been £4865 per QALY gained. The service was effective at identifying people with HCV infection, and despite the additional cost of targeted testing, its cost-effectiveness was below the commonly accepted thresholds. In this setting, restricting targeted testing to PWID would not improve the cost-effectiveness.


Assuntos
Hepatite C/diagnóstico , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Assistência Farmacêutica/economia , Adulto , Antivirais/uso terapêutico , Análise Custo-Benefício , Teste em Amostras de Sangue Seco/economia , Teste em Amostras de Sangue Seco/métodos , Usuários de Drogas , Feminino , Hepacivirus/genética , Hepatite C/tratamento farmacológico , Hepatite C/economia , Hepatite C Crônica/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Saúde Pública/economia , Saúde Pública/métodos , RNA Viral , Fatores de Risco , Abuso de Substâncias por Via Intravenosa , Resposta Viral Sustentada , Reino Unido
17.
J Clin Microbiol ; 58(1)2019 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-31666365

RESUMO

We evaluated the performance of a fourth-generation antigen/antibody (Ag/Ab) assay for detecting HIV-1 infection on dried blood spots (DBS) both in a conventional laboratory environment and in an epidemiological survey corresponding to a real-life situation. Although a 2-log loss of sensitivity compared to that with plasma was observed when using DBS in an analytical analysis, the median delay of positivity between DBS and crude serum during the early phase postacute infection was 7 days. The performance of the fourth-generation assay on DBS was approximately similar to that of a third-generation (antibody only) assay using crude serum samples. Among 2,646 participants of a cross-sectional study in a population of men having sex with men, 428 DBS were found reactive, but negative results were obtained from 5 DBS collected from individuals who self-reported a positive HIV status, confirmed by detection of antiretroviral (ARV) drugs in their DBS. The data generated allowed us to estimate a sensitivity of 98.8% of the fourth-generation assay/DBS strategy in a high-risk population, even including a broad majority of individuals on ARV treatment among those HIV positive. Our study brings additional proofs that DBS testing using a fourth-generation immunoassay is a reliable strategy able to provide alternative approaches for both individual HIV testing and surveillance of various populations.


Assuntos
Teste em Amostras de Sangue Seco , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV , Imunoensaio , Fármacos Anti-HIV/farmacologia , Fármacos Anti-HIV/uso terapêutico , Estudos Transversais , Teste em Amostras de Sangue Seco/métodos , Teste em Amostras de Sangue Seco/normas , HIV/efeitos dos fármacos , HIV/imunologia , Anticorpos Anti-HIV/imunologia , Antígenos HIV/imunologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/imunologia , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soroconversão
18.
Anal Bioanal Chem ; 411(26): 6825-6835, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31410536

RESUMO

A rapid and low-cost method of diagnosis is becoming important for detecting fetal inherited diseases, including single-gene disorders and chromosomal abnormalities. Here, we demonstrated an innovation that use paper-dried cord blood (PCB) as the starting material for PCR and whole genome amplification without any DNA extraction step at a very low cost. A novel PCR buffer named "DDB buffer" containing ammonium sulfate and glycerol were used instead of the conventional 10× PCR buffer. The amplicons were directly analyzed through microchip electrophoresis and whole genome sequencing. Inhibitory substances in filter paper were effectively inactivated using DDB buffer. Direct PCR amplification of DNA fragments ranging from 100 to 900 bp using filter paper spotted with 0.5 to 5 µL of cord blood and various anticoagulants was successful. We were able to determine fetal single-gene disorders and chromosomal diseases in all 46 chromosomes using PCB samples successfully. Compared with prenatal diagnosis using purified DNA, the proposed method is simple, fast, less prone to cross-contamination at minimal cost. Researchers and clinical and healthcare workers may employ this method for genetic diagnosis using cord blood samples with minimum laboratory resources. This method is very promising for a variety of genetic diagnosis applications in underserved communities at the point of need in developing areas. Graphical abstract.


Assuntos
Transtornos Cromossômicos/genética , DNA/genética , Teste em Amostras de Sangue Seco/métodos , Diagnóstico Pré-Natal/métodos , Transtornos Cromossômicos/diagnóstico , Teste em Amostras de Sangue Seco/economia , Sangue Fetal/metabolismo , Humanos , Papel , Reação em Cadeia da Polimerase/métodos , Diagnóstico Pré-Natal/economia , Fatores de Tempo
19.
Ther Drug Monit ; 41(6): 714-718, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31169760

RESUMO

BACKGROUND: Dried blood spot (DBS) sampling is a blood collection tool that uses a finger prick to obtain a blood drop on a DBS card. It can be used for therapeutic drug monitoring, a method that uses blood drug concentrations to optimize individual treatment. DBS sampling is believed to be a simpler way of blood collection compared with venous sampling. The aim of this study was to evaluate the quality of DBSs from patients with tuberculosis all around the world based on quality indicators in a structured assessment procedure. METHODS: Total 464 DBS cards were obtained from 4 countries: Bangladesh, Belarus, Indonesia, and Paraguay. The quality of the DBS cards was assessed using a checklist consisting of 19 questions divided into 4 categories: the integrity of the DBS materials, appropriate drying time, blood volume, and blood spot collection. RESULTS: After examination, 859 of 1856 (46%) blood spots did not comply with present quality criteria. In 625 cases (34%), this was due to incorrect blood spot collection. The DBS cards from Bangladesh, Indonesia, and Paraguay seemed to be affected by air humidity, causing the blood spots not to dry appropriately. CONCLUSIONS: New tools to help obtain blood spots of sufficient quality are necessary and environmental specific recommendations to determine plasma concentration correctly. In addition, 3% of the DBS cards were rejected because the integrity of the materials suggesting that the quality of plastic ziplock bags currently used to protect the DBS cards against contamination and humidity may not be sufficient.


Assuntos
Antituberculosos/sangue , Teste em Amostras de Sangue Seco/normas , Monitoramento de Medicamentos/métodos , Manejo de Espécimes/normas , Tuberculose/sangue , Bangladesh , Teste em Amostras de Sangue Seco/métodos , Humanos , Umidade , Indonésia , Paraguai , Reprodutibilidade dos Testes , República de Belarus , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Tuberculose/diagnóstico , Tuberculose Pulmonar
20.
PLoS One ; 14(6): e0218353, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31206533

RESUMO

BACKGROUND: Blood collection, transportation and storage remain a problem in countries where infrastructure, laboratory facilities and skilled manpower are scarce. This limits evaluation of immune responses in natural infections and vaccination in field studies. We developed methods to measure antigen specific antibody responses using dried blood spot (DBS) in cholera, ETEC and typhoid fever patients as well as recipients of oral cholera vaccine (OCV). METHODOLOGY/PRINCIPLE FINDINGS: We processed heparinized blood for preparing DBS and plasma specimens from patients with, cholera, ETEC and typhoid as well as OCV recipients. We optimized the conventional vibriocidal method to measure vibriocidal antibody response in DBS eluates. We measured responses in DBS samples and plasma (range of titer of 5 to 10240). Vibriocidal titer showed strong agreement between DBS eluates and plasma in cholera patients (ICC = 0.9) and in OCV recipients (ICC = 0.8) using the Bland-Altman analysis and a positive correlation was seen (r = 0.7, p = 0.02 and r = 0.6, p = 0.006, respectively). We observed a strong agreement of lipopolysaccharide (LPS) and cholera toxin B (CTB)-specific antibody responses between DBS eluates and plasma in cholera patients and OCV recipients. We also found agreement of heat labile toxin B (LTB) and membrane protein (MP)-specific antibody responses in DBS eluates and plasma specimen of ETEC and typhoid patients respectively. CONCLUSION: Our results demonstrate that dried blood specimens can be used as an alternate method for preservation of samples to measure antibody responses in enteric diseases and vaccine trials and can be applied to assessment of responses in humanitarian crisis and other adverse field settings.


Assuntos
Formação de Anticorpos , Cólera/imunologia , Teste em Amostras de Sangue Seco/métodos , Escherichia coli Enterotoxigênica/imunologia , Enteropatias/imunologia , Febre Tifoide/imunologia , Coleta de Amostras Sanguíneas/métodos , Vacinas contra Cólera/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA