Clin Investig Arterioscler ; 36(3): 195-199, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38584065

RESUMO

Cardiovascular disease secondary to atherosclerosis is the main cause of morbidity and mortality in the world. Cardiovascular risk stratification has proven to be an insufficient approach to detect those subjects who are going to suffer a cardiovascular event, which is why for years other markers have been sought to help stratify each individual with greater precision. Two-dimensional vascular ultrasound is a excellent method for vascular risk assessment.


Assuntos
Aterosclerose , Humanos , Aterosclerose/diagnóstico por imagem , Medição de Risco/métodos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/etiologia , Ultrassonografia/métodos , Fatores de Risco de Doenças Cardíacas
2.
Ultrason Imaging ; 46(3): 178-185, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38622911

RESUMO

To evaluate the inter-observer variability and the intra-observer repeatability of pulmonary transit time (PTT) measurement using contrast-enhanced ultrasound (CEUS) in healthy rabbits, and assess the effects of dilution concentration of ultrasound contrast agents (UCAs) on PTT. Thirteen healthy rabbits were selected, and five concentrations UCAs of 1:200, 1:100, 1:50, 1:10, and 1:1 were injected into the right ear vein. Five digital loops were obtained from the apical 4-chamber view. Four sonographers obtained PTT by plotting the TIC of right atrium (RA) and left atrium (LA) at two time points (T1 and T2). The frame counts of the first appearance of UCAs in RA and LA had excellent inter-observer agreement, with intra-class correlations (ICC) of 0.996, 0.988, respectively. The agreement of PTT among four observers was all good at five different concentrations, with an ICC of 0.758-0.873. The reproducibility of PTT obtained by four observers at T1 and T2 was performed well, with ICC of 0.888-0.961. The median inter-observer variability across 13 rabbits was 6.5% and the median variability within 14 days for 4 observers was 1.9%, 1.7%, 2.2%, 1.9%, respectively; The PTT of 13 healthy rabbits is 1.01 ± 0.18 second. The difference of PTT between five concentrations is statistically significant. The PTT obtained by a concentration of 1:200 and 1:100 were higher than that of 1:1, while there were no significantly differences in PTT of a concentration of 1:1, 1:10, and 1:50. PTT measured by CEUS in rabbits is feasible, with excellent inter-observer and intra-observer reliability and reproducibility, and dilution concentration of UCAs influences PTT results.


Assuntos
Meios de Contraste , Estudos de Viabilidade , Variações Dependentes do Observador , Ultrassonografia , Animais , Coelhos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Hexafluoreto de Enxofre/farmacocinética , Circulação Pulmonar/fisiologia
3.
Endocrinol Metab (Seoul) ; 39(2): 310-323, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38590123

RESUMO

BACKGRUOUND: There is debate about ultrasonography screening for thyroid cancer and its cost-effectiveness. This study aimed to evaluate the cost-effectiveness of early screening (ES) versus symptomatic detection (SD) for differentiated thyroid cancer (DTC) in Korea. METHODS: A Markov decision analysis model was constructed to compare the cost-effectiveness of ES and SD. The model considered direct medical costs, health outcomes, and different diagnostic and treatment pathways. Input data were derived from literature and Korean population studies. Incremental cost-effectiveness ratio (ICER) was calculated. Willingness-to-pay (WTP) threshold was set at USD 100,000 or 20,000 per quality-adjusted life year (QALY) gained. Sensitivity analyses were conducted to address uncertainties of the model's variables. RESULTS: In a base case scenario with 50 years of follow-up, ES was found to be cost-effective compared to SD, with an ICER of $2,852 per QALY. With WTP set at $100,000, in the case with follow-up less than 10 years, the SD was cost-effective. Sensitivity analysis showed that variables such as lobectomy probability, age, mortality, and utility scores significantly influenced the ICER. Despite variations in costs and other factors, all ICER values remained below the WTP threshold. CONCLUSION: Findings of this study indicate that ES is a cost-effective strategy for DTC screening in the Korean medical system. Early detection and subsequent lobectomy contribute to the cost-effectiveness of ES, while SD at an advanced stage makes ES more cost-effective. Expected follow-up duration should be considered to determine an optimal strategy for DTC screening.


Assuntos
Análise Custo-Benefício , Detecção Precoce de Câncer , Anos de Vida Ajustados por Qualidade de Vida , Neoplasias da Glândula Tireoide , Ultrassonografia , Humanos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/economia , Neoplasias da Glândula Tireoide/diagnóstico , República da Coreia/epidemiologia , Detecção Precoce de Câncer/economia , Detecção Precoce de Câncer/métodos , Ultrassonografia/economia , Ultrassonografia/métodos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Cadeias de Markov
5.
Clin Hemorheol Microcirc ; 86(3): 263-273, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38489171

RESUMO

BACKGROUND: The continuous development of ultrasound techniques increasingly enables better description and visualization of unclear lesions. New ultrasound systems must be evaluated with regard to all these diagnostic possibilities. METHODS: A multifrequency C1-7 convex probe (SC7-1M) with the new high-end system Resona A20 Series was used. Modern technologies, including HiFR CEUS, SR CEUS and multimodal tissue imaging with shear wave elastography (SWE), fat evaluation and viscosity measurements (M-Ref) were applied. RESULTS: Of n = 70 (mean value 48,3 years±20,3 years, range 18-84 years) cases examined, a definitive diagnosis could be made in n = 67 cases, confirmed by reference imaging and/or follow-up. Of these, n = 22 cases were malignant changes (HCC (hepatocellular carcinoma) n = 9, CCC (cholangiocellular carcinoma) n = 3, metastases of colorectal carcinomas or recurrences of HCC n = 10). In all 12 cases of HCC or CCC, the elastography measurements using the shear wave technique (with values >2 m/s to 3.7 m/s) showed mean values of 2.3±0.31 m/s and a degree of fibrosis of F2 to F4. In n = 14 cases, changes in the fat measurement (range 0.51 to 0.72 dB/cm/MHz, mean values 0.58±0.12 dB/cm/MHz) in the sense of proportional fatty changes in the liver were detected. In the 4 cases of localized fat distribution disorders, the values were >0.7 dB/cm/MHz in the sense of significant fatty deposits in the remaining liver tissue. Relevant changes in the viscosity measurements with values >1.8 kPa were found in n = 31 cases, in n = 5 cases of cystic lesions with partially sclerosing cholangitis, in n = 13 cases of malignant lesions and in n = 9 cases post-interventionally, but also in n = 4 cases of benign foci with additional systemic inflammation. CONCLUSIONS: The results are promising and show a new quality of ultrasound-based liver diagnostics. However, there is a need for further investigations with regard to the individual aspects, preferably on a multi-center basis.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Humanos , Técnicas de Imagem por Elasticidade/métodos , Meios de Contraste , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Viscosidade , Fígado/diagnóstico por imagem , Fígado/patologia , Ultrassonografia/métodos
6.
Diabetes Metab Res Rev ; 40(3): e3787, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38461408

RESUMO

AIMS: Given the increasing number of individuals developing metabolic dysfunction-associated steatotic liver disease (MASLD) and the low rate of those with progressive liver disease, there is a pressing need to conceive affordable biomarkers to assess MASLD in general population settings. Herein, we aimed to investigate the performance of the ultrasound-derived fat fraction (UDFF) for hepatic steatosis in high-risk individuals. METHODS: A total of 302 Europeans with obesity, type 2 diabetes, or a clinical history of hepatic steatosis were included in the analyses. Clinical, laboratory, and imaging data were collected using standardized procedures during a single screening visit in Rome, Italy. Hepatic steatosis was defined by controlled attenuation parameter (CAP) or ultrasound-based Hamaguchi's score. UDFF performance for hepatic steatosis was estimated by the area under the receiver operating characteristic curve (AUC). RESULTS: Overall, median (IQR) UDFF was 12% (7-20). UDFF was positively correlated with CAP (ρ = 0.73, p < 0.0001) and Hamaguchi's score (ρ = 0.79, p < 0.0001). Independent predictors of UDFF were circulating triglycerides, alanine aminotransferase (ALT), and ultrasound-measured visceral adipose tissue (VAT). UDFF AUC was 0.89 (0.85-0.93) and 0.92 (0.88-0.95) for CAP- and ultrasound-diagnosed hepatic steatosis, respectively. UDFF AUC for hepatic steatosis was higher than those of fatty liver index (FLI), hepatic steatosis index (HSI), CAP-score (CAPS), and ALT (p < 0.0001). Lower age, ALT, and VAT were associated with discordance between UDFF and ultrasound. CONCLUSIONS: UDFF may be a simple and accurate imaging biomarker to assess hepatic steatosis and monitor changes in hepatic fat content over time or in response to therapeutic interventions beyond clinical trials.


Assuntos
Diabetes Mellitus Tipo 2 , Fígado Gorduroso , Doenças Metabólicas , Hepatopatia Gordurosa não Alcoólica , Humanos , Diabetes Mellitus Tipo 2/metabolismo , Fígado Gorduroso/complicações , Fígado Gorduroso/diagnóstico por imagem , Fígado , Ultrassonografia/métodos , Curva ROC , Biomarcadores/metabolismo , Doenças Metabólicas/metabolismo , Hepatopatia Gordurosa não Alcoólica/diagnóstico
7.
Exp Biol Med (Maywood) ; 249: 10064, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38463389

RESUMO

Ultrasonographic characteristics of skeletal muscles are related to their health status and functional capacity, but they still provide limited information on muscle composition during the inflammatory process. It has been demonstrated that an alteration in muscle composition or structure can have disparate effects on different ranges of ultrasonogram pixel intensities. Therefore, monitoring specific clusters or bands of pixel intensity values could help detect echotextural changes in skeletal muscles associated with neurogenic inflammation. Here we compare two methods of ultrasonographic image analysis, namely, the echointensity (EI) segmentation approach (EI banding method) and detection of selective pixel intensity ranges correlated with the expression of inflammatory regulators using an in-house developed computer algorithm (r-Algo). This study utilized an experimental model of neurogenic inflammation in segmentally linked myotomes (i.e., rectus femoris (RF) muscle) of rats subjected to lumbar facet injury. Our results show that there were no significant differences in RF echotextural variables for different EI bands (with 50- or 25-pixel intervals) between surgery and sham-operated rats, and no significant correlations among individual EI band pixel characteristics and protein expression of inflammatory regulators studied. However, mean numerical pixel values for the pixel intensity ranges identified with the proprietary r-Algo computer program correlated with protein expression of ERK1/2 and substance P (both 86-101-pixel ranges) and CaMKII (86-103-pixel range) in RF, and were greater (p < 0.05) in surgery rats compared with their sham-operated counterparts. Our findings indicate that computer-aided identification of specific pixel intensity ranges was critical for ultrasonographic detection of changes in the expression of inflammatory mediators in neurosegmentally-linked skeletal muscles of rats after facet injury.


Assuntos
Inflamação Neurogênica , Músculo Quadríceps , Ratos , Animais , Músculo Quadríceps/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Ultrassonografia/métodos , Processamento de Imagem Assistida por Computador
8.
J Anesth ; 38(3): 347-353, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38430260

RESUMO

PURPOSE: Ultrasound performed after extubation has been suggested to be useful for the diagnosis of recurrent laryngeal nerve (RLN) paralysis. However, the use of ultrasound for this purpose before extubation has not been examined. The aim of this study was to examine the versatility (interrater reliability) and usefulness of ultrasound for evaluating the movement of vocal cords before extubation. METHODS: The subjects were 30 patients who underwent radical surgery for esophageal cancer from August 2020 to December 2021. An experienced examiner performed an ultrasound examination before and after elective extubation on the day after surgery to evaluate RLN paralysis and record videos. Bronchoscopy was then performed to make a definite diagnosis. Three anesthetists blinded to the diagnosis also evaluated the cases using the videos, and the versatility of the examination was determined using a kappa test. RESULTS: The diagnostic accuracies of the examiner and three anesthetists were 76.7%, 50.0%, 53.3%, and 46.7%, respectively, and the kappa coefficients for the examiner with the anesthetists were 0.310, 0.502, and 0.169, respectively. The sensitivity, specificity, positive predictive value and negative predictive value for diagnosis of RLN paralysis by the examiner using ultrasound before extubation were 0.57, 0.95, 0.80, and 0.87, respectively. CONCLUSION: These results indicate a lack of versatility of the ultrasound examination based on the low kappa coefficients. However, with an experienced examiner, ultrasound can serve as a non-invasive examination that can be performed before extubation with high accuracy and specificity for diagnosis of postoperative RLN paralysis.


Assuntos
Neoplasias Esofágicas , Ultrassonografia , Paralisia das Pregas Vocais , Humanos , Estudos Prospectivos , Masculino , Feminino , Neoplasias Esofágicas/cirurgia , Paralisia das Pregas Vocais/diagnóstico por imagem , Paralisia das Pregas Vocais/etiologia , Idoso , Pessoa de Meia-Idade , Ultrassonografia/métodos , Extubação/métodos , Reprodutibilidade dos Testes , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico , Nervo Laríngeo Recorrente/diagnóstico por imagem , Sensibilidade e Especificidade
9.
Radiol Med ; 129(5): 785-793, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512620

RESUMO

Dysfunction of the masseter muscle may cause pathological kinking of the parotid duct leading to parotitis; MR sialography is a non-invasive radiological examination that allows to evaluate dynamically the ductal system of the parotid glands. In the present study we aimed to assess the relationships between Stensen's duct and masseter muscle and their implications in the aetiopathogenesis of recurrent parotitis secondary to masseter muscle dysfunction. Forty-one patients with recurrent unilateral parotitis and nine with bilateral recurrent parotitis, all with a clinical suspicious of masseter muscle hypertrophy due to bruxism were enrolled. They underwent ultrasonography as a first line examination and then MR sialography and sialendoscopy. Different anatomical features were studied. Involved parotid glands had a wider duct compared to contralateral unaffected parotid glands of patients with recurrent parotitis (p = 0.00134); male subjects with parotitis had a longer duct compared to the salivary glands of healthy patients (p = 0.00943 for affected glands and p = 0.00629 for the contralateral). A concordance between the evidence of an acute duct angle during sialendoscopy and a wider duct in patients with parotitis was observed although not statistically significant. These initial findings suggest that the masticatory muscle dysfunction related to bruxism seems to condition alteration of parotid duct course and anatomy thus favouring the occurrence of recurrent parotitis. A specific diagnostic iter based on clinical evaluation, dynamic ultrasonography and MR sialography, is therefore, mandatory to confirm the relationship between masseter muscle anatomy and parotid duct anomalies; this is the premise for an adequate therapeutic approach to underlying masticatory muscle disorder.


Assuntos
Imageamento por Ressonância Magnética , Músculo Masseter , Parotidite , Recidiva , Sialografia , Humanos , Masculino , Parotidite/diagnóstico por imagem , Feminino , Músculo Masseter/diagnóstico por imagem , Adulto , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Sialografia/métodos , Ductos Salivares/diagnóstico por imagem , Ultrassonografia/métodos , Idoso , Bruxismo/diagnóstico por imagem , Bruxismo/complicações , Endoscopia/métodos
10.
Gynecol Obstet Invest ; 89(2): 111-119, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38377973

RESUMO

OBJECTIVE: The aim of the study was to evaluate the diagnostic accuracy for parametria endometriosis (PE) of transvaginal sonography (TVS) performed following a systematic approach for the assessment of the lateral parametria. DESIGN: A diagnostic accuracy study was employed based on a prospective observational design. PARTICIPANTS: All consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020 were considered. SETTING: The study was conducted at endometriosis referral hospitals. METHODS: We prospectively collected clinical, imaging, and surgical data of all consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020. A standardized technique with a systematic approach for the assessment of the lateral parametria following specific anatomic landmarks was used for the TVS. The diagnostic accuracy for PE in TVS was assessed using the intraoperative and pathologic diagnosis of PE as the gold standard. RESULTS: In 476 patients who underwent surgery, PE was identified in 114 out of 476 patients (23.95%): 91 left and 54 right PE out of 476 surgical procedures were identified (19.12% vs. 11.34%; p = 0.001); bilateral involvement in 27.19% (31/114 patients) cases. The sensitivity of TVS for PE was 90.74% (79.70-96.92%, 95% CI) for the right side and 87.91% (79.40-93.81%, 95% CI) for the left side. The specificity was almost identical for both sides (98.58% vs. 98.18%). For the right parametrium, the positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 63.82 (28.70-141.90, 95% CI) and 0.09 (0.04-0.22, 95% CI), respectively. On the left parametrium, the PLR and NLR were 48.35 (23.12-101.4, 95% CI) and 0.12 (0.07-0.21, 95% CI), respectively. The diagnostic accuracy for right and left PE was 97.69% (95.90-98.84%, 95% CI) and 96.22% (94.04-97.74%, 95% CI), respectively. LIMITATIONS: The principal limit is the high dependence of TVS on the operator experience. Therefore, although a standardized approach following precise definitions of anatomical landmarks was used, we cannot conclude that the observed accuracy of TVS for PE is the same for all sonographers. In this regard, the learning curve was not assessed. In the case of negative TVS for parametrial involvement with an absent intraoperative suspect, a complete dissection of the parametrium was not performed to avoid surgical complications; therefore, cases of minor PE may be missed, underestimating false negatives. CONCLUSIONS: TVS performed following a systematic approach for assessing the lateral parametria seems to have good diagnostic accuracy for PE with large changes in the posttest probability of parametrial involvement based on the TVS evaluation. Considering the clinical and surgical implications of PE, further studies implementing a standardized approach for assessing the parametrium by TVS are recommended to confirm our observations and implement a standardized protocol in clinical practice.


Assuntos
Endometriose , Laparoscopia , Feminino , Humanos , Endometriose/diagnóstico por imagem , Endometriose/cirurgia , Ultrassonografia/métodos , Sensibilidade e Especificidade , Vagina/diagnóstico por imagem , Vagina/cirurgia , Vagina/patologia
11.
Ultrasound Med Biol ; 50(5): 647-660, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38355361

RESUMO

OBJECTIVE: Scoliosis is a spinal deformation in which the spine takes a lateral curvature, generating an angle in the coronal plane. The conventional method for detecting scoliosis is measurement of the Cobb angle in spine images obtained by anterior X-ray scanning. Ultrasound imaging of the spine is found to be less ionising than traditional radiographic modalities. For posterior ultrasound scanning, alternate indices of the spinous process angle (SPA) and ultrasound curve angle (UCA) were developed and have proven comparable to those of the traditional Cobb angle. In SPA, the measurements are made using the spinous processes as an anatomical reference, leading to an underestimation of the traditionally used Cobb angles. Alternatively, in UCA, more lateral features of the spine are employed for measurement of the main thoracic and thoracolumbar angles; however, clear identification of bony features is required. The current practice of UCA angle measurement is manual. This research attempts to automate the process so that the errors related to human intervention can be avoided and the scalability of ultrasound scoliosis diagnosis can be improved. The key objective is to develop an automatic scoliosis diagnosis system using 3-D ultrasound imaging. METHODS: The novel diagnosis system is a three-step process: (i) finding the ultrasound spine image with the most visible lateral features using the convolutional RankNet algorithm; (ii) segmenting the bony features from the noisy ultrasound images using joint spine segmentation and noise removal; and (iii) calculating the UCA automatically using a newly developed centroid pairing and inscribed rectangle slope method. RESULTS: The proposed method was evaluated on 109 patients with scoliosis of different severity. The results obtained had a good correlation with manually measured UCAs (R2=0.9784 for the main thoracic angle andR2=0.9671 for the thoracolumbar angle) and a clinically acceptable mean absolute difference of the main thoracic angle (2.82 ± 2.67°) and thoracolumbar angle (3.34 ± 2.83°). CONCLUSION: The proposed method establishes a very promising approach for enabling the applications of economic 3-D ultrasound volume projection imaging for mass screening of scoliosis.


Assuntos
Escoliose , Humanos , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Ultrassonografia/métodos , Radiografia , Imageamento Tridimensional
12.
Ultrasound Med Biol ; 50(6): 825-832, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38423896

RESUMO

OBJECTIVE: B-lines assessed by lung ultrasound (LUS) outperform physical exam, chest radiograph, and biomarkers for the associated diagnosis of acute heart failure (AHF) in the emergent setting. The use of LUS is however limited to trained professionals and suffers from interpretation variability. The objective was to utilize transfer learning to create an AI-enabled software that can aid novice users to automate LUS B-line interpretation. METHODS: Data from an observational AHF LUS study provided standardized cine clips for AI model development and evaluation. A total of 49,952 LUS frames from 30 patients were hand scored and trained on a convolutional neural network (CNN) to interpret B-lines at the frame level. A random independent evaluation set of 476 LUS clips from 60 unique patients assessed model performance. The AI models scored the clips on both a binary and ordinal 0-4 multiclass assessment. RESULTS: A multiclassification AI algorithm had the best performance at the binary level when applied to the independent evaluation set, AUC of 0.967 (95% CI 0.965-0.970) for detecting pathologic conditions. When compared to expert blinded reviewer, the 0-4 multiclassification AI algorithm scale had a reported linear weighted kappa of 0.839 (95% CI 0.804-0.871). CONCLUSIONS: The multiclassification AI algorithm is a robust and well performing model at both binary and ordinal multiclass B-line evaluation. This algorithm has the potential to be integrated into clinical workflows to assist users with quantitative and objective B-line assessment for evaluation of AHF.


Assuntos
Insuficiência Cardíaca , Pulmão , Ultrassonografia , Humanos , Insuficiência Cardíaca/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Ultrassonografia/métodos , Doença Aguda , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina
13.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401294

RESUMO

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.


Assuntos
Gota , Doenças Pulmonares Intersticiais , Doenças Musculares , Humanos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Padrões de Referência
14.
J Emerg Med ; 66(2): 197-210, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38309979

RESUMO

BACKGROUND: Ocular emergencies comprise 2-3% of emergency department (ED) visits, with retinal detachment requiring emergency surgery. Two-dimensional ultrasound is a rapid bedside tool but is highly operator dependent. OBJECTIVE: We determined three-dimensional ultrasound (3DUS) feasibility, acceptability, and usability in eye pathology detection using the ophthalmologist examination as reference standard. METHODS: We performed a prospective, blinded cohort study of a 3DUS-enabling device in 30 eye clinic and ED patients with visual symptoms and calculated 3DUS performance characteristics. Two expert readers interpreted the 3DUS images for pathology. All participants completed surveys. RESULTS: 3DUS sensitivity was 0.81, specificity 0.73, positive predictive value 0.54, negative predictive value 0.91, and likelihood ratio (LR)+/LR- 3.03 and 0.26, respectively. Novice and expert sonographers had "substantial" agreement in correct diagnosis of abnormal vs. normal (κ = 0.68, 95% confidence interval 0.48-0.88). Most patients indicated that 3DUS is fast, comfortable, helps them understand their problem, and improves provider interaction/care, and all sonographers agreed; 4/5 sonographers felt confident performing ultrasound. Expert readers correctly identified an abnormal eye in 83/120 scans (76%) and correct diagnosis in 72/120 scans (65%), with no statistical difference between novice (79%; 69%) and expert (72%; 61%) sonographers (p = 0.39, p = 0.55), suggesting reduced operator dependence. Reader diagnosis confidence and image quality varied widely. Image acquisition times were fast for novice (mean 225 ± 83 s) and expert (201 ± 51) sonographers, with fast expert reader interpretation times (225 ± 136). CONCLUSIONS: A 3DUS-enabling device demonstrates a sensitivity of 0.81 and specificity of 0.73 for disease detection, fast image acquisition, and may reduce operator dependence for detecting emergent retinal pathologies. Further technological development is needed to improve diagnostic accuracy in identifying and characterizing retinal pathology.


Assuntos
Serviço Hospitalar de Emergência , Humanos , Estudos de Coortes , Estudos Prospectivos , Estudos de Viabilidade , Sensibilidade e Especificidade , Ultrassonografia/métodos
16.
Zhonghua Jie He He Hu Xi Za Zhi ; 47(2): 172-177, 2024 Feb 12.
Artigo em Chinês | MEDLINE | ID: mdl-38309970

RESUMO

The use of lung ultrasound in the screening, diagnosis, and evaluation of interstitial lung disease has been relatively well studied, but has not been widely accepted and applied in clinical practice. There are also some differences in the examination methods applied in these studies. This paper summarized the application, advantages, and disadvantages of lung ultrasound in the diagnosis and follow-up of interstitial lung disease by comprehensively reviewing the examination methods, research results and progress of new technologies of lung ultrasound in interstitial lung disease.


Assuntos
Doenças Pulmonares Intersticiais , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Ultrassonografia/métodos , Tórax
17.
Med Ultrason ; 26(1): 7-14, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38244221

RESUMO

AIM: To explore benefits of high-frame-rate contrast-enhanced ultrasonography (H-CEUS) for early kidney injury in a rabbit model of diabetic nephropathy (DN). METHODS: Diabetic rabbits were induced with alloxan administration and split into 2 groups with or without urinary microalbuminuria after a fatty and sugary diet: diabetic rabbits with nephropathy (Group A) and diabetic rabbits without nephropathy (Group B). The control group (Group C) comprised healthy rabbits. Renal H-CEUS and conventional CEUS (C-CEUS) imaging were conducted. Serum creatinine (SCR), blood urea nitrogen (BUN) and urinary microalbuminuria were measured. RESULTS: SCR and BUN levels were barely changed in Groups B and C (p>0.05), whereas Group A exhibited a rise (p<0.05). Perfusion parameters of the two CEUS modalities showed reduced peak intensity (PI) and ascending slope (AS) and elevated area under the curve (AUC) and time to peak (TTP) in Group A versus Group B (p<0.05) and Group B versus Group C (p<0.05). The arrival time (AT) and descending slope (DS) exhibited little difference among the three groups. H-CEUS had a stronger correlation of perfusion parameters with SCR and BUN than C-CEUS. CONCLUSIONS:  H-CEUS outperforms C-CEUS in diagnosing early renal damage in DN. H-CEUS perfusion parameters demonstrate temporal superiority over routine laboratory indices.


Assuntos
Diabetes Mellitus , Nefropatias Diabéticas , Sistema Urinário , Animais , Coelhos , Nefropatias Diabéticas/diagnóstico por imagem , Meios de Contraste , Rim/diagnóstico por imagem , Ultrassonografia/métodos
18.
J Ultrasound Med ; 43(4): 697-711, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38189176

RESUMO

OBJECTIVES: To determine the added diagnostic value of contrast-enhanced ultrasound (CEUS) in pediatric chest abnormalities by comparing interpretation of CEUS studies and confidence level to conventional US studies. METHODS: CEUS studies in patients with a variety of clinically suspected chest abnormalities performed between 2016 and 2020 were reviewed and compared to same-day conventional US studies. Examinations were independently interpreted by 4 radiologists blinded to clinical and other imaging data. Rater confidence was classified as low, moderate, or high. Diagnostic accuracy was determined by comparing image interpretation to patient outcome as the ground truth. Interobserver agreement was also assessed. RESULTS: Sixteen patients (10 male) with 18 CEUS studies were included. Median rater agreement with ground truth was significantly higher for CEUS (100%) than conventional US (50%; P = .004). Median rater confidence was high (3.0) for CEUS, and low-moderate (1.5) for conventional US (P < .001). CEUS sensitivity (54.6-81.8%) and specificity (63.4-100.0%) were greater than conventional US (45.5-72.7% and 12.5-63.5%, respectively). CEUS false positives (0-4) and false negatives (2-5) were fewer than conventional US (4-7 and 3-6, respectively). Except for one rater pair where agreement was substantial (κ = .78, P < .01), inter-rater agreement for CEUS for all other rater pairs was nonsignificant (κ = .25-0.51, P ≥ .07). Agreement for conventional US was moderate and statistically significant for 3 rater pairs (κ = .55-0.78) and nonsignificant for the remaining 3 rater pairs (P ≥ .06). CONCLUSIONS: CEUS adds diagnostic value to the assessment of a variety of chest abnormalities. The data support further evaluation of the role of CEUS as a non-invasive, problem-solving technique in children.


Assuntos
Meios de Contraste , Aumento da Imagem , Humanos , Masculino , Adolescente , Criança , Projetos Piloto , Ultrassonografia/métodos , Aumento da Imagem/métodos , Exame Físico , Sensibilidade e Especificidade
19.
J Clin Anesth ; 94: 111404, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38290374

RESUMO

STUDY OBJECTIVE: Interpretation of gastric ultrasound relies on the use of a clinical algorithm that combines qualitative analysis of the gastric antrum contents with the calculation of the volume of fluid contents. This reference method may be difficult to apply in the parturient. We therefore aimed to assess the diagnostic accuracy of a simple qualitative assessment in the supine position for the diagnosis of high-risk gastric contents in the parturient. We also assessed the diagnostic accuracy of a composite scale and another clinical algorithm based on a mathematical model different to that used in the reference method. DESIGN: Prospective observational cohort study. SETTING: University hospital, Lyon, France. PATIENTS: Adult women admitted to the delivery room. INTERVENTIONS: Qualitative and quantitative gastric ultrasound examination within the first hour following admission. MEASUREMENTS: With respect to the reference method, the diagnostic accuracy of a simple qualitative assessment for the diagnosis of high-risk gastric contents was assessed. The diagnostic accuracy of a composite scale and another clinical algorithm, and the agreement between each approach were also assessed. MAIN RESULTS: A total of 235 parturients were included and analyzed. The simple qualitative assessment led to conclusive ultrasound assessment in 233 (99%) women, while the reference method led to conclusive assessment in 213 (91%) women (P < 0.05). The sensitivity and the specificity of the simple qualitative assessment were 97% (95%CI: 93 to 99%) and 96% (95%CI: 90 to 99%), respectively. These were not significantly different from those of the composite scale and the clinical algorithm. The four approaches showed almost perfect agreement with each other. CONCLUSIONS: These results suggest that simple qualitative assessment may be useful in clinical practice to help the anesthesiologist in the assessment of gastric contents status and risk of aspiration.


Assuntos
Antro Pilórico , Estômago , Adulto , Humanos , Feminino , Masculino , Estudos Prospectivos , Estômago/diagnóstico por imagem , Antro Pilórico/diagnóstico por imagem , Ultrassonografia/métodos , Aspiração Respiratória
20.
Clin Endocrinol (Oxf) ; 100(6): 595-601, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38226504

RESUMO

INTRODUCTION: Hyponatraemia is the most common electrolyte disorder in inpatients resulting mainly from an imbalance in water homeostasis. Intravascular fluid status assessment is pivotal but is often challenging given multimorbidity, polypharmacy and diuretics use. We evaluated the utility of point-of-care ultrasound (POCUS) as an adjunct tool to standard practice for fluid assessment in severe hyponatraemia patients. METHODS: Patients presenting with severe hyponatremia (Serum Sodium [Na] < 120 mmol/L; Normal range: 135-145 mol/L), managed by standard care were included. Hyponatraemia biochemistry work-up and POCUS examination were undertaken. Both clinician and POCUS independently assigned one of the three fluid status groups of hypovolaemia, hypervolaemia or euvolaemia. The final diagnosis of three fluid status groups at admission was made at the time of discharge by retrospective case review. Clinician's (standard of care) and POCUS fluid assessments were compared to that of the final diagnosis at the time of discharge. RESULTS: n = 19 patients were included. Median Na on admission was 113 mmol/L (109-116), improved to 129 ± 3 mmol/L on discharge. POCUS showed the higher degree of agreement with the final diagnosis (84%; n = 16/19), followed by the clinician (63%; n = 12/19). A trend towards higher accuracy of POCUS compared to clinician assessment of fluid status was noted (84% vs. 63%, p = 0.1611). Biochemistry was unreliable in 58% (n = 11/19) likely due to renal failure, polypharmacy or diuretic use. Inappropriate emergency fluid management was undertaken in 37% (n = 7/19) of cases based on initial clinician assessment. Thirst symptom correlated to hypovolaemia in 80% (4/5) cases. CONCLUSION: As subjective clinical and biochemistry assessments of fluid status are often unreliable due to co-morbidities and concurrent use of medications, POCUS can be a rapid objective diagnostic tool to assess fluid status in patients with severe hyponatraemia, to guide accurate emergency fluid management.


Assuntos
Hiponatremia , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Hiponatremia/diagnóstico por imagem , Feminino , Masculino , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto