Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Mod Rheumatol ; 31(2): 334-342, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32243209

RESUMO

OBJECTIVE: Although recent clinical trials showed that ultrasound (US) remission is not required to achieve good outcomes at the group level, it currently remains unclear whether the prognosis of individual patients in clinical remission, but not US remission, i.e. those with subclinical sonographic synovitis (SSS), is favorable. However, it is no longer acceptable to perform US on all patients in order to identify those with SSS. Therefore, the present study was initiated to elucidate the conditions under which SSS is frequently detected. METHODS: In total, 563 consecutive RA patients were recruited. Bilateral 2-5 MCP, wrist, ankle, and 2-5 MTP joints were scanned by US, and Gray scale and Power Doppler (PD) images were scored semi-quantitatively. Clinical data were obtained by physicians who were blind to US results. Changes in the modified Total Sharp Score (mTSS) of tocilizumab (TCZ) users were calculated. RESULTS: A total of 402 patients were included. SSS was more frequently detected in patients with more severe joint deformity, even if they were in remission. In contrast, a high Patient Global Assessment of Disease (PtGA) did not reflect SSS. Furthermore, the relationship between PtGA and PD scores was weak. Although the frequency of SSS was high in TCZ user, the presence of SSS in TCZ users not always results in the progression of mTSS. CONCLUSIONS: While remission is overestimated in patients with severe joint deformity, underestimations may occur in those who do not fulfill remission criteria because of a high PtGA.


Assuntos
Artrite Reumatoide/diagnóstico por imagem , Sinovite/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Adulto , Idoso , Articulação do Tornozelo/diagnóstico por imagem , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/patologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Indução de Remissão , Sinovite/tratamento farmacológico , Sinovite/patologia , Ultrassonografia Doppler/normas , Articulação do Punho/diagnóstico por imagem
2.
Clin Exp Dermatol ; 46(2): 314-318, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32572993

RESUMO

Vascular malformations classification may pose a diagnostic challenge for physicians. In the early stages, they are diagnosed clinically mainly by visual inspection. For a deeper analysis, Doppler ultrasonography is the preferred technique to determine the haemodynamic behaviour of the anomaly. However, this imaging method is not always available and it requires trained operators to acquire and interpret the images. There is a lack of portable and user-friendly systems that may help physicians in the assessment of vascular malformations. We propose a new diagnostic procedure, more affordable and easier to use, based on a portable thermal camera. This technique provides information about temperature, which has been found to be correlated with the flow rate of the lesion. In our study, > 60 vascular malformations of previously diagnosed patients were analysed with a thermal camera to classify them into low-flow and high-flow malformations. The value was 1 for both sensitivity and specificity of this technique.


Assuntos
Termografia/instrumentação , Termografia/estatística & dados numéricos , Malformações Vasculares/diagnóstico , Velocidade do Fluxo Sanguíneo/fisiologia , Temperatura Corporal/fisiologia , Diagnóstico Diferencial , Hemodinâmica/fisiologia , Humanos , Sensibilidade e Especificidade , Termografia/economia , Termografia/métodos , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/normas , Malformações Vasculares/classificação , Malformações Vasculares/patologia
4.
Am J Physiol Heart Circ Physiol ; 318(2): H301-H325, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31886718

RESUMO

The introduction of duplex Doppler ultrasound almost half a century ago signified a revolutionary advance in the ability to assess limb blood flow in humans. It is now widely used to assess blood flow under a variety of experimental conditions to study skeletal muscle resistance vessel function. Despite its pervasive adoption, there is substantial variability between studies in relation to experimental protocols, procedures for data analysis, and interpretation of findings. This guideline results from a collegial discussion among physiologists and pharmacologists, with the goal of providing general as well as specific recommendations regarding the conduct of human studies involving Doppler ultrasound-based measures of resistance vessel function in skeletal muscle. Indeed, the focus is on methods used to assess resistance vessel function and not upstream conduit artery function (i.e., macrovasculature), which has been expertly reviewed elsewhere. In particular, we address topics related to experimental design, data collection, and signal processing as well as review common procedures used to assess resistance vessel function, including postocclusive reactive hyperemia, passive limb movement, acute single limb exercise, and pharmacological interventions.


Assuntos
Fármacos Cardiovasculares/farmacologia , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/diagnóstico por imagem , Ultrassonografia Doppler/normas , Resistência Vascular/fisiologia , Humanos , Músculo Esquelético/efeitos dos fármacos , Projetos de Pesquisa , Resistência Vascular/efeitos dos fármacos
5.
Ultrasound Obstet Gynecol ; 56(2): 182-186, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31180608

RESUMO

OBJECTIVES: To determine the quality of Doppler images of the fetal middle cerebral artery (MCA) and umbilical artery (UA) using an objective scale, and to determine the reliability of this scale, within a multicenter randomized controlled trial (Revealed versus concealed criteria for placental insufficiency in unselected obstetric population in late pregnancy (Ratio37)). METHODS: The Ratio37 trial is an ongoing randomized, open-label, multicenter controlled study of women with a low-risk pregnancy recruited at 20 weeks. Doppler measurements of the fetal MCA and UA were performed at 37 weeks. Twenty patients from each of the six participating centers were selected randomly, with two images evaluated per patient (one each for the MCA and UA). The quality of a total of 240 images was evaluated by six experts, scored on an objective scale of six items. Inter- and intrarater reliability was assessed using the Fleiss-modified kappa statistic for ordinal scales. RESULTS: On average, 89.2% of MCA images and 85.0% of UA images were rated as being of perfect (score of 6) or almost perfect (score of 5) quality. Kappa values for intrarater reliability of quality assessment were 0.90 (95% CI, 0.88-0.92) and 0.90 (95% CI, 0.88-0.93) for the MCA and UA, respectively. The corresponding inter-rater reliability values were 0.85 (95% CI, 0.81-0.89) and 0.84 (95% CI, 0.80-0.89), respectively. CONCLUSION: The quality of MCA and UA Doppler ultrasound images can be evaluated reliably using an objective scale. Over 85% of images, which were obtained by operators from a broad range of clinical practices within a multicenter study, were rated as being of perfect or almost perfect quality. Intra- and inter-rater reliability of quality assessment was very good. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Feto/diagnóstico por imagem , Artéria Cerebral Média/diagnóstico por imagem , Ultrassonografia Doppler/normas , Ultrassonografia Pré-Natal/normas , Artérias Umbilicais/diagnóstico por imagem , Adulto , Feminino , Feto/irrigação sanguínea , Feto/embriologia , Humanos , Artéria Cerebral Média/embriologia , Garantia da Qualidade dos Cuidados de Saúde , Ensaios Clínicos Controlados Aleatórios como Assunto , Reprodutibilidade dos Testes , Artérias Umbilicais/embriologia
6.
Am J Physiol Heart Circ Physiol ; 317(6): H1376-H1387, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31702970

RESUMO

There is still lack of a simple, accurate, and noninvasive method for rat aortic pulse wave velocity (PWV) measurement, especially the transit distance cannot be accurately measured. Thus, we aimed to derive an equation for aortic transit distance as a function of the nose-to-rump length (L) and to test the hypothesis that aortic PWV measured by new equation combined with Doppler ultrasound (the "equation method") may have stronger correlation with invasive measurements than traditional "body surface method." Two-hundred male Sprague-Dawley (SD) rats (age ranged 5-24 wk) were included in protocol 1, and the aortic transit distances were measured postmortem. In protocol 2, heart-femoral PWV and carotid-femoral PWV were measured by equation method (hfPWVE, cfPWVE) and also by traditional body surface method (hfPWVS, cfPWVS) in another 30 young and 28 old rats. These measurements were then validated against invasively measured hfPWVI and cfPWVI from the same animal. Protocol 1 showed that the heart-femoral transit distance could be calculated by 0.6086 × L - 1.6523, and the carotid-femoral transit distance by 0.4614 × L + 1.8335. In protocol 2, in young rats, the Pearson r between hfPWVE, cfPWVE, hfPWVS, and cfPWVS and their corresponding invasive measurement were 0.8962, 0.8509, 0.8387, and 0.7828, respectively (all P < 0.0001). In the old group, the results were 0.8718, 0.7999, 0.8330, and 0.7112, respectively (all P < 0.0001). The hfPWVE and cfPWVE showed better agreement with hfPWVI and cfPWVI and lower intra- and interobserver variability compared with hfPWVS and cfPWVS in both groups. These findings demonstrate that this novel methodology provides a simple and reliable method for rat noninvasive aortic PWV measurement.NEW & NOTEWORTHY First, when measuring aortic PWV in SD rat models, the heart-femoral transit distance can be estimated by 0.6086 × L - 1.6523, and the carotid-femoral distance transit distance can be estimated by 0.4614 × L + 1.8335, where L (in mm) is nose-to-rump length. Second, this novel methodology for aortic PWV measurement was validated with a closer correlation with the invasive measurements than traditional approach in young and old rats. Third, this study provides a simple and reliable method for rat noninvasive aortic PWV measurement.


Assuntos
Aorta/fisiologia , Velocidade da Onda de Pulso Carótido-Femoral/métodos , Ultrassonografia Doppler/métodos , Envelhecimento/fisiologia , Animais , Aorta/diagnóstico por imagem , Aorta/crescimento & desenvolvimento , Velocidade da Onda de Pulso Carótido-Femoral/normas , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Ultrassonografia Doppler/normas
7.
Intern Emerg Med ; 14(5): 705-711, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30712149

RESUMO

Lower extremity venous thrombosis (DVT) is the most common vascular manifestation of Behçet's syndrome (BS). Currently, Doppler ultrasonography (USG) is the most commonly preferred imaging modality in the diagnosis and follow-up of patients with acute and chronic DVT. Magnetic resonance (MR) venography, a quick and a non-invasive imaging modality, is successfully used to detect DVT in various settings. We had been unaware of studies with MR venography in BS. The aim of this study is to compare the diagnostic value of true fast imaging with steady-state precession magnetic resonance (True-FISP MR) venography and Doppler USG in the assessment of chronic DVT among patients with BS. 28 BS patients with chronic lower extremity DVT were studied. Common femoral (CFV) and femoral vein (FV) on both right and left sides were examined for the presence of thrombosis, recanalisation, collaterals and reflux. There are findings of chronic DVT in all Doppler USG images of 28 patients (45 of 56 FV and 35 of 56 CFV), while MR venography detects chronic thrombotic changes in 26/28 (93%) patients (43 of 52 FV and 28 of 52 CFV). Collateral veins are detected in 19 patients (19/28) with MR venography, whereas they are present in only 7 (7/28) with USG (P = 0.003). Furthermore, patients with severe post-thrombotic syndrome are more likely to have collateral formation on the MR compared to those without (12/14 vs 7/14; P = 0.043). Among patients with BS, MR venography might be an alternative or additional method to detect chronic thrombosis in the lower extremities.


Assuntos
Síndrome de Behçet/fisiopatologia , Flebografia/normas , Ultrassonografia Doppler/normas , Trombose Venosa/patologia , Adulto , Síndrome de Behçet/complicações , Síndrome de Behçet/diagnóstico , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/normas , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/fisiopatologia , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Ultrassonografia Doppler/métodos , Trombose Venosa/etiologia , Trombose Venosa/fisiopatologia
8.
Zhejiang Da Xue Xue Bao Yi Xue Ban ; 48(4): 453-458, 2019 06 25.
Artigo em Chinês | MEDLINE | ID: mdl-31901052

RESUMO

OBJECTIVE: To analyze the application of three-dimensional power Doppler sonography (3-DPDS) in evaluation of the superior mesenteric artery (SMA) and superior mesenteric vein (SMV) in second-trimester fetus. METHODS: Three-dimensional volume probe was used to collect the 3-DPDS blood flow images in 50 normal fetuses of 22+0-24+6 weeks and 50 fetuses of 30+0-32+6 weeks, respectively. The characteristics of three-dimensional ultrasound were analyzed. The clinical and imaging data of 4 fetuses of 26+3-32+1 weeks with midgut volvulus were analyzed retrospectively. RESULTS: The display rates of SMA and SMV were 93%in normal group by 3-DPDS and those in volvulus group were 4/4 and 3/4, respectively. The SMV trunk was parallel to and on the right side of the SMA in the normal group, while 3 cases in volvulus group showed the characteristic relationship of SMV swirling around SMA. CONCLUSIONS: 3-DPDS can be used to observe the spatial relationship of SMA and SMV visually in fetus during the second trimester and is of value to diagnose and predict the outcome of midgut volvulus.


Assuntos
Artéria Mesentérica Superior , Ultrassonografia Doppler , Anormalidades do Sistema Digestório/diagnóstico por imagem , Feminino , Feto , Humanos , Volvo Intestinal/diagnóstico por imagem , Artéria Mesentérica Superior/diagnóstico por imagem , Gravidez , Segundo Trimestre da Gravidez , Estudos Retrospectivos , Ultrassonografia Doppler/normas
9.
Eur J Appl Physiol ; 118(6): 1209-1219, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29569054

RESUMO

PURPOSE: Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test-retest reliability has been investigated. METHODS: Fixation of the ultrasound probe on the upper leg allowed for continuous PDUS measurements. Cycling exercise protocols included a submaximal and an incremental exercise to maximal power. The relative perfused area (RPA) was determined as a measure of perfusion. Absolute and relative reliability of RPA amplitude and kinetic parameters during exercise (onset, slope, maximum value) and recovery (overshoot, decay time constants) were investigated. RESULTS: A RPA increase during exercise followed by a signal recovery was measured in all volunteers. Amplitudes and kinetic parameters during exercise and recovery showed poor to good relative reliability (ICC ranging from 0.2-0.8), and poor to moderate absolute reliability (coefficient of variation (CV) range 18-60%). CONCLUSIONS: A method has been demonstrated which allows for continuous (Power Doppler) ultrasonography and assessment of perfusion dynamics in skeletal muscle during exercise. The reliability of the RPA amplitudes and kinetics ranges from poor to good, while the reliability of the RPA increase in submaximal cycling (ICC = 0.8, CV = 18%) is promising for non-invasive clinical assessment of the muscle perfusion response to daily exercise.


Assuntos
Exercício Físico , Músculo Quadríceps/irrigação sanguínea , Fluxo Sanguíneo Regional , Ultrassonografia Doppler/métodos , Adulto , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/fisiologia , Masculino , Músculo Quadríceps/fisiologia , Ultrassonografia Doppler/normas
10.
Eur J Appl Physiol ; 118(2): 249-260, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29192355

RESUMO

PURPOSE: It has recently been shown that venous occlusion plethysmography (VOP) can successfully assess the rate of increase in leg blood flow (LBF) (LBF kinetics) responses during calf exercise, but there is lack of data supporting its validity. METHODS: Using Doppler ultrasound (DU) as a criterion standard technique, we tested the hypothesis that VOP would provide similar estimates of LBF kinetics responses as DU during calf plantar-flexion exercise at a range of different intensities. Ten healthy men performed repeated intermittent calf plantar-flexion contractions (3 s duty cycles, 1 s contraction/2 s relaxation) at 30, 50 and 70% maximum voluntary contraction (MVC) on different days. RESULTS: Resting LBF values were significantly (P < 0.05) larger for DU than VOP but the overall mean LBF responses during exercise were not different (P > 0.05) between DU and VOP (30% MVC: 330 ± 78 vs. 313 ± 92 ml/min; 50% MVC: 515 ± 145 vs. 483 ± 164 ml/min; 70% MVC: 733 ± 218 vs. 616 ± 229 ml/min). LBF kinetics analyses revealed that the end-amplitude at the highest intensity (70% MVC) was significantly higher when measured by DU compared with VOP, but all other kinetics parameters were not different between VOP and DU. CONCLUSIONS: Given that these slight differences in amplitude observed during exercise can be explained by differences in vascular regions which the two techniques assess, our results suggest that VOP can accurately assess LBF kinetics responses during calf plantar-flexion exercise at intensities between 30 and 70% MVC.


Assuntos
Exercício Físico , Extremidade Inferior/fisiologia , Pletismografia/métodos , Fluxo Sanguíneo Regional , Ultrassonografia Doppler/métodos , Adulto , Humanos , Extremidade Inferior/irrigação sanguínea , Masculino , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/fisiologia , Pletismografia/normas , Ultrassonografia Doppler/normas
11.
J Crit Care ; 40: 46-51, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28324786

RESUMO

OBJECTIVE: Assessment of Corrected Flow Time (FTc) in carotid artery has been suggested recently as a measure of intravascular volume status. This study aimed to determine the reference values of FTc in carotid artery in a normal population. METHODS: A total number of 142 healthy volunteers (73 females and 69 males) with a mean age of 36.65±10.52years were included. RESULTS: The mean FTc in carotid artery was 325.18±22.15ms0.5. The mean value of FTc differed significantly between females and males both before and after passive leg raise (PLR) (330.18±21.61ms0.5 vs. 319.88±21.62, P=0.005 before PLR, and 336.89±22.95ms0.5 vs. 326.51±21.21, P=0.006 after PLR). CONCLUSION: This study would potentially pave the way to determine clinically significant cutoff points in order to assess the diagnostic accuracy of FTc in predicting intravascular volume status and fluid therapy responsiveness.


Assuntos
Artérias Carótidas/fisiopatologia , Estado Terminal , Sistemas Automatizados de Assistência Junto ao Leito/normas , Ultrassonografia Doppler/normas , Adulto , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Feminino , Humanos , Perna (Membro)/irrigação sanguínea , Masculino , Estudos Prospectivos , Fluxo Pulsátil , Valores de Referência , Reprodutibilidade dos Testes
12.
Ultraschall Med ; 37(3): 297-302, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27093520

RESUMO

The early fetal ultrasound assessment at 11 - 13(+6) weeks of gestation remains the cornerstone of care despite the progress in diagnosing fetal chromosomal defects using cell-free fetal DNA (cffDNA) from the maternal circulation. The measurement of nuchal translucency (NT) allows the risk calculation for the fetal trisomies 21, 18 and 13 but also gives information on those fetal chromosomal defects which are at present unable to be detected using cffDNA. Nuchal translucency is the only auditable parameter at 11 - 13(+6) weeks and gives thus information on the quality of the first trimester anomaly scan. In addition it gives indirect information on the risks for fetal defects and for cardiac anomalies. Also the chances for a healthy live baby can be estimated. As experience with first trimester anomaly scanning increases, and the resolution of the ultrasound equipment has increased substantially, more and more details of the fetal anatomy become accessible at the first trimester scan. Therefore fetal anatomical defects and complex anomalies have become amenable to examination in the first trimester. This guideline describes compulsory and optional parameters for investigation at the first trimester scan and outlines a structured method of examining a first trimester fetus at 11 - 13(+6) weeks of gestation.


Assuntos
Primeiro Trimestre da Gravidez , Garantia da Qualidade dos Cuidados de Saúde/normas , Ultrassonografia Pré-Natal/normas , Biometria , Aberrações Cromossômicas/embriologia , Endossonografia , Feminino , Humanos , Medição da Translucência Nucal/normas , Gravidez , Segundo Trimestre da Gravidez , Sociedades Médicas , Ultrassonografia Doppler/normas
14.
J Mal Vasc ; 39(1): 26-46, 2014 Feb.
Artigo em Francês | MEDLINE | ID: mdl-24448056

RESUMO

The quality standards of the French Society for Vascular Medicine for the ultrasound assessment of the superficial venous system of the lower limbs are based on the two following requirements: technical know-how (mastering the use of ultrasound devices and the method of examination); medical know-how (ability to adapt the methods and scope of the examination to its clinical indications and purpose and to rationally analyze and interpret its results). AIMS OF THE QUALITY STANDARDS: To describe an optimal method of examination in relation to the clinical question and hypothesis; to achieve consistent practice, methods, glossary terminologies and reporting; to provide good practice reference points and to promote a high quality process. THEMES OF THE QUALITY STANDARD: The three levels of examination. Their clinical indications and goals. The reference standard examination (level 2) and its variants according to clinical needs. The minimal content of the examination report, the letter to the referring physician (synthesis, conclusion and management suggestions) and iconography. Commented glossary (anatomy, hemodynamics, semiology). Technical basis. Ultrasound devices settings. We discuss of use of Duplex ultrasound for the assessment of the superficial veins of the lower limbs in vascular medicine practice.


Assuntos
Tromboflebite/diagnóstico por imagem , Ultrassonografia Doppler/normas , Varizes/diagnóstico por imagem , Veia Femoral/diagnóstico por imagem , Humanos , Terapia a Laser , Perna (Membro)/diagnóstico por imagem , Ilustração Médica , Exame Físico/normas , Veia Safena/diagnóstico por imagem , Escleroterapia , Simbolismo , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos , Ultrassonografia de Intervenção , Varizes/cirurgia , Varizes/terapia
15.
BMC Cardiovasc Disord ; 13: 81, 2013 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-24103352

RESUMO

BACKGROUND: Ankle-brachial-Index (ABI) measured by manual Dopplersonography is an easily assessable marker of global cardiovascular risk. The aim of this study was to establish novel photo-plethysmography (PPG)-based ABI assessments in an epidemiologic context and to compare its results with those of Doppler. METHODS: Two devices for PPG-based ABI assessments (Vicorder, Vascular Explorer) were tested and compared against Doppler in 56 putatively healthy subjects. We determined acceptance, time requirements, agreement of repeat measurements, agreement with Doppler and intra- and inter-observer concordances for both devices and compared the results. Differences between cuff inflation- and deflation-based methods were also studied for Vascular Explorer. RESULTS: Acceptance was similar for both devices but Vascular Explorer was more time consuming. Agreement of multiple measurements was moderate for both methods highlighting the importance of measurement replicates. Both automated devices showed significantly higher ABI compared to Doppler which can be traced back to higher brachial pressures (Vicorder) or higher ankle pressures (Vascular Explorer). This effect is more pronounced for Vascular Explorer but can be ameliorated using the deflation method of measurement. Intra-observer concordances were similar. Inter-observer concordance was non-significantly better for Vicorder. CONCLUSIONS: Both devices proved to be feasible in epidemiologic studies, but compared to Doppler, do not constitute an advantage regarding time requirement and accuracy of ABI assessment. Since PPG-based ABI values are inflated compared to Doppler, it will be necessary to adjust Doppler-based cut-offs for risk stratification.


Assuntos
Índice Tornozelo-Braço/normas , Fotopletismografia/normas , Ultrassonografia Doppler/normas , Idoso , Índice Tornozelo-Braço/métodos , Automação , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Projetos Piloto
16.
J Mal Vasc ; 38(1): 29-42, 2013 Feb.
Artigo em Francês | MEDLINE | ID: mdl-23312609

RESUMO

THE QUALITY STANDARDS OF THE FRENCH SOCIETY OF VASCULAR MEDICINE FOR THE ULTRASONOGRAPHIC ASSESSMENT OF VASCULAR MALFORMATIONS ARE BASED ON THE TWO FOLLOWING REQUIREMENTS: Technical know-how: mastering the use of ultrasound devices and the method of examination. Medical know-how: ability to adapt the methods and scope of the examination to its clinical indication and purpose, and to rationally analyze and interpret its results. AIMS OF THE QUALITY STANDARDS: To describe an optimal method of examination in relation to the clinical question and hypothesis. To achieve consistent practice, methods, glossary, and reporting. To provide good practice reference points, and promote a high-quality process. ITEMS OF THE QUALITY STANDARDS: The three levels of examination; their clinical indications and goals. The reference standard examination (level 2), its variants according to clinical needs. The minimal content of the examination report; the letter to the referring physician (synthesis, conclusion and proposal for further investigation and/or therapeutic management). Commented glossary (anatomy, hemodynamics, semiology). Technical bases. Settings and use of ultrasound devices. Here, we discuss the methods of using ultrasonography for the assessment of peripheral vascular malformations and tumors.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Ultrassonografia Doppler/normas , Malformações Vasculares/diagnóstico por imagem , Neoplasias Vasculares/diagnóstico por imagem , Braço/irrigação sanguínea , Artérias/diagnóstico por imagem , Hemangioma/diagnóstico por imagem , Humanos , Perna (Membro)/irrigação sanguínea , Linfangioma/diagnóstico por imagem , Exame Físico/métodos , Exame Físico/normas , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia Doppler em Cores/normas , Ultrassonografia Doppler de Pulso/métodos , Ultrassonografia Doppler de Pulso/normas , Ultrassonografia de Intervenção/normas , Malformações Vasculares/classificação , Veias/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem
17.
J Sex Med ; 10(1): 120-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22970798

RESUMO

INTRODUCTION: In-office evaluation of erectile dysfunction by color duplex Doppler ultrasound (CDDU) may benefit the decision-making process in regard to choosing the most appropriate therapy. Unfortunately, there is no uniform standardization in performing CDDU resulting in high variability in data expression and interpretation when comparing results among various centers, especially when conducting multicenter trials. Establishing standard operating procedures (SOPs) is a major step that will help minimize such variability. AIM: This SOP describes CDDU procedure with focus on establishing uniformity and normative parameters. MAIN OUTCOME MEASURE: Measure intra-arterial diameter, peak systolic velocity, end-diastolic velocity, and resistive index for each cavernosal artery. METHODS: After initial discussion with the patient about his history and International Index of Erectile Function evaluation describe procedural steps to the patient. Perform the CDDU in a relaxed state, scanning the entire penis (in B-mode image) using a 7.5- to 12-MHz linear array ultrasound probe. An intracorporal injection of a single or combination of vasoactive agents (e.g., prostaglandin E1, phentolamine, and papaverine) is then administered and CDDU performed at various time points, preferably with audiovisual sexual stimulation (AVSS). RESULTS: Monitor penile erection response (tumescence and rigidity) near peak blood flow. Self-stimulation or AVSS leaving the patient alone in room or redosing may be considered to decrease any anxiety and help achieve a maximum rigid erection. CONCLUSION: Considering the complexity and heterogeneity of CDDU evaluation, this communication will help in standardization and establish uniformity in such data interpretation. When indicated, invasive diagnostic testing involving (i) penile angiography and (ii) cavernosography/cavernosometry to establish veno-occlusive dysfunction may be recommended to facilitate further treatment options.


Assuntos
Disfunção Erétil/diagnóstico por imagem , Impotência Vasculogênica/diagnóstico por imagem , Protocolos Clínicos/normas , Disfunção Erétil/diagnóstico , Humanos , Impotência Vasculogênica/diagnóstico , Masculino , Ereção Peniana/fisiologia , Pênis/irrigação sanguínea , Pênis/diagnóstico por imagem , Guias de Prática Clínica como Assunto/normas , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/normas
18.
Intensive Care Med ; 38(7): 1105-17, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22614241

RESUMO

PURPOSE: To provide clinicians with an evidence-based overview of all topics related to ultrasound vascular access. METHODS: An international evidence-based consensus provided definitions and recommendations. Medical literature on ultrasound vascular access was reviewed from January 1985 to October 2010. The GRADE and the GRADE-RAND methods were utilised to develop recommendations. RESULTS: The recommendations following the conference suggest the advantage of 2D vascular screening prior to cannulation and that real-time ultrasound needle guidance with an in-plane/long-axis technique optimises the probability of needle placement. Ultrasound guidance can be used not only for central venous cannulation but also in peripheral and arterial cannulation. Ultrasound can be used in order to check for immediate and life-threatening complications as well as the catheter's tip position. Educational courses and training are required to achieve competence and minimal skills when cannulation is performed with ultrasound guidance. A recommendation to create an ultrasound curriculum on vascular access is proposed. This technique allows the reduction of infectious and mechanical complications. CONCLUSIONS: These definitions and recommendations based on a critical evidence review and expert consensus are proposed to assist clinicians in ultrasound-guided vascular access and as a reference for future clinical research.


Assuntos
Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Ultrassonografia Doppler/métodos , Ultrassonografia de Intervenção/métodos , Adulto , Cateterismo Venoso Central/normas , Cateterismo Periférico/normas , Criança , Conferências de Consenso como Assunto , Análise Custo-Benefício , Medicina Baseada em Evidências , Humanos , Recém-Nascido , Ultrassonografia Doppler/normas , Ultrassonografia de Intervenção/normas
19.
Singapore Med J ; 52(4): 271-3, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21552789

RESUMO

INTRODUCTION: The aim of this study was to investigate the value of renal resistive index (RI) for the assessment of renal colic and to determine whether it is predictive of renal stone disease. METHODS: A total of 70 participants were included in the research study. Group 1 comprised 43 patients with acute unilateral ureteral obstruction due to a stone disease (G1), while Group 2 consisted of seven patients with flank pain without stone disease (G2) and the control group comprised 20 healthy individuals with two normal kidneys (G3). Urinalysis, abdominal plain film radiography, conventional ultrasonography (US) and colour Doppler US were performed in all three groups. RI was calculated for all patients using Doppler US. The RI values in G1 were then compared with those in G2 and the control group. RESULTS: There were statistically significant differences in the RI between the stone-positive group and stone-free groups (0.71 +/- 0.07 for G1; 0.69 +/- 0.06 for G2; 0.62 +/- 0.03 for G3, p-value < 0.05). CONCLUSION: RI measurement using Doppler US can be effectively used for the assessment of renal colic patients by non-invasive means.


Assuntos
Cálculos Renais/diagnóstico , Nefrologia/métodos , Cólica Renal/diagnóstico , Adolescente , Adulto , Idoso , Serviço Hospitalar de Emergência , Feminino , Humanos , Rim/diagnóstico por imagem , Rim/fisiologia , Cálculos Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia/métodos , Cólica Renal/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler/normas
20.
Ultraschall Med ; 32 Suppl 1: S27-34, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20938896

RESUMO

PURPOSE: The aim of the study was to assess the influence of technical factors and/or lesion characteristics on the final elastographic score in solid breast nodules. MATERIALS AND METHODS: Patients with solid breast masses examined between May 2007 and May 2008 in the Radiology Department of Cluj District University Hospital were included in the study. All lesions were examined with conventional ultrasound, Doppler ultrasound and sonoelastography, according to a preset protocol. The influence of the following factors on the elastographic score was evaluated: type of section (sagittal versus transverse); size of region of interest (small versus large); amplitude and frequency of movement; initial compression (light versus strong); angulation (perpendicular versus angulated transducer); characteristics of the lesion (size and location). The reference diagnosis was the histopathology diagnosis and, in twenty cases, short-term follow-up. RESULTS: Ninety-two patients with a mean age of 48.11 years and 101 breast nodules were included in the study. The overall sensitivity and specificity for elastography were 79 % [68-88 %] and 79 % [65 - 89 %], respectively, with a negative predictive value of 74 % [60-85 %] and a positive predictive value of 84 % [72-91 %]. The following factors did not influence the elastographic score: type of section (scores on transverse and longitudinal section, Z = -0.641, p = 0.552); the amplitude and frequency of movements during the elastographic examination (Cochran's Q concordance = 0.706, p = 0.872); strong initial compression in the case of benign nodules (Z = 0.000, p = 1.000); size of the lesions. Of the elastographically benign nodules, 9 were false negative and of the 46 elastographically malignant nodules, 12 were false positive. The following factors influenced the elastographic scores: size of the region of interest (the scores were significantly different when small or large region of interest was used, Z = -0.671, p < 0.0001); transducer angulation (Z = -5.42, p < 0.0001); strong initial compression in the case of malignant nodules (Z = -6.044, p < 0.0001) and the location of the mass in the vicinity of the chest wall. CONCLUSION: The most important factors that influence the final elastographic score, leading to false negative results, are the size of the region of interest, the initial compression and angulation of the transducer, while the frequency and amplitude of movement during the examination proved to be of no importance as long as the images were obtained within a range of assessment usefulness. Changing the scanning parameters never led to false positive results in the case of malignant breast masses.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/métodos , Carga Tumoral/fisiologia , Ultrassonografia Doppler/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/patologia , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Lobular/diagnóstico por imagem , Carcinoma Lobular/patologia , Técnicas de Imagem por Elasticidade/normas , Feminino , Fibroadenoma/diagnóstico por imagem , Fibroadenoma/patologia , Humanos , Processamento de Imagem Assistida por Computador/normas , Mesenquimoma/diagnóstico por imagem , Mesenquimoma/patologia , Pessoa de Meia-Idade , Invasividade Neoplásica , Tumor Filoide/diagnóstico por imagem , Tumor Filoide/patologia , Valor Preditivo dos Testes , Transdutores , Ultrassonografia Doppler/normas , Ultrassonografia Mamária/normas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA