Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J Cardiovasc Imaging ; 25(6): 739-753, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38376989

RESUMO

The immediate result of percutaneous balloon mitral commissurotomy is largely determined by the anatomy of the mitral valve complex. Several scores and models have been developed to assess anatomical suitability for percutaneous balloon mitral commissurotomy. Although none has an optimal predictive power, these models look at the valvular apparatus from different perspectives bearing the potential for a complementary role.


Assuntos
Estenose da Valva Mitral , Humanos , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Valvuloplastia com Balão , Feminino , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/anatomia & histologia , Cateterismo Cardíaco/métodos , Seleção de Pacientes , Medição de Risco , Resultado do Tratamento , Índice de Gravidade de Doença , Valor Preditivo dos Testes
2.
Curr Probl Cardiol ; 48(12): 102021, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37544629

RESUMO

Echocardiography is an important diagnostic imaging modality in recognizing rheumatic heart disease, a chronic sequelae of acute rheumatic fever. Left-sided heart valves, especially the mitral valve is typically affected, with stenosis or regurgitation as a consequence. Although assessment of valve area by 2D planimetry is the reference method for mitral stenosis severity, 3D planimetry provides more accurate measurement and diagnostic value. Careful selection of patients in terms of echocardiographic criteria is essential to ensure safety and success of the intervention and better long-term outcomes. Several echocardiographic scores based upon mitral valve mobility, thickening, calcification, and subvalvular thickening are developed to assess mitral valve anatomy and the feasibility of percutaneous mitral commissurotomy. 3D transesophageal echocardiography (TEE) provides detailed information of the mitral anatomy (commissural fusions, and subvalvular apparatus) before intervention. In addition, 3D TEE planimetry provides a more accurate measurement of the valve area compared with 2D echocardiography. Generally, huge annular calcification and lack of commissural fusion are unfavorable echocardiographic markers that increase the risk of complications and preclude the feasibility of percutaneous balloon mitral valvuloplasty. More contemporary prospective echocardiography research studies on patients with RHD from low- and middle-income countries are needed.


Assuntos
Valvuloplastia com Balão , Calcinose , Estenose da Valva Mitral , Cardiopatia Reumática , Humanos , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/terapia , Estudos Prospectivos , Ecocardiografia/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Valvuloplastia com Balão/efeitos adversos
3.
J Vet Cardiol ; 45: 71-78, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36716612

RESUMO

INTRODUCTION/OBJECTIVES: Pulmonary stenosis (PS) is a congenital defect in the dog that is managed with balloon valvuloplasty (BV). Obstruction severity is routinely assessed using transthoracic echocardiography. The objectives of this study were to describe the short-term changes and long-term restenosis by retrospectively evaluating flow-dependent and flow-independent echocardiographic variables for dogs with PS after BV. ANIMALS, MATERIALS, AND METHODS: Medical records and stored echocardiographic images were reviewed from dogs that received BV for PS. The following echocardiographic variables were measured or calculated: maximum systolic ejection velocity (VmaxPV) and velocity-derived maximal pressure gradient (PV maxPG) across the pulmonary valve; ratio of aortic to pulmonary velocity time integral (VTIAV/VTIPV); ratio of aortic to pulmonary maximal velocity. RESULTS: Eighty-one dogs with PS that had a BV were included. Each of these dogs had pulmonary obstruction severity assessed in at least three timepoints. Forty-nine dogs had at least one additional examination performed, the last of which occurred a median of 504 days after the BV. Echocardiographic variables at the first follow-up had increased by a clinically relevant quantity in 20-34% of the dogs when comparing to the immediate post-BV examination. The last follow-up examination identified valve restenosis in 18-38% of the dogs in this study. Valve type and pre-BV obstruction severity did not have a significant effect (P > 0.1). CONCLUSIONS: For the assessment of BV efficacy, the immediate post-BV echocardiogram may not be as useful as the first follow-up examination several months later. Pulmonary restenosis after BV may be more prevalent than previously reported.


Assuntos
Valvuloplastia com Balão , Doenças do Cão , Doenças das Valvas Cardíacas , Estenose da Valva Pulmonar , Cães , Animais , Valvuloplastia com Balão/veterinária , Valvuloplastia com Balão/métodos , Estudos Retrospectivos , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/terapia , Doenças do Cão/congênito , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/veterinária , Doenças das Valvas Cardíacas/veterinária , Ecocardiografia/veterinária , Constrição Patológica/veterinária
4.
Cardiol J ; 29(2): 245-251, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34708864

RESUMO

BACKGROUND: The treatment of choice for severe rheumatic mitral stenosis (MS) is balloon mitral valvuloplasty (BMV). Assessment of MS severity is usually performed by echocardiography. Before performing BMV, invasive hemodynamic assessment is also performed. The effect of anesthesia on the invasive assessment of MS severity has not been studied. The purpose of the present study was to assess changes in invasive hemodynamic measurement of MS severity before and after induction of general anesthesia. METHODS: The medical files of 22 patients who underwent BMV between 2014 and 2020 were reviewed. Medical history, laboratory, echocardiographic and invasive measurements were collected. Anesthesia induction was performed with etomidate or propofol. Pre-procedural echocardiographic measurements of valve area using pressure half time, and continuity correlated well with invasive measurements using the Gorlin formula. RESULTS: After induction of anesthesia the mean mitral valve gradient dropped by 2.4 mmHg (p = 0.153) and calculated mitral valve area (MVA) increased by 0.2 cm2 (p = 0.011). A wide variability in individual response was observed. While a drop in gradient was noted in 14 patients, it increased in 7. Gorlin derived MVA rose in most patients but dropped in 4. Assuming a calculated MVA of 1.5 cm2 and below to define clinically significant MS, 4 patients with pre-induction MVA of 1.5 cm2 or below had calculated MVA above 1.5 cm2 after induction. CONCLUSIONS: The impact of general anesthesia on the hemodynamic assessment of MS is heterogeneous and may lead to misclassification of MS severity.


Assuntos
Anestesia , Valvuloplastia com Balão , Estenose da Valva Mitral , Hemodinâmica , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estenose da Valva Mitral/diagnóstico
5.
Eur J Clin Invest ; 50(12): e13374, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32789848

RESUMO

BACKGROUND: The epidemiology and management of diseases can be influenced by social demographic factors. Gender and migration are among these factors. METHODS: We aimed at reviewing the impacts of gender and migration on rheumatic heart disease (RHD) epidemiology and management by a nonsystematic literature review of published studies on RHD worldwide. Our PubMed search terms included RHD pathophysiology, diagnosis, complications, management or prevention, combined with words 'rheumatic mitral stenosis (MS)', 'outcomes after percutaneous balloon mitral valvuloplasty (PBMV)', 'gender or sex difference' and 'migration'. The reporting of this study conforms to SANRA (the Scale for Assessment of Narrative Review Articles) guidelines. RESULTS: We retrieved eight studies about the impact of sex on outcomes after PBMV. All of these studies showed a female predominance for RHD. Two studies showed that there is no impact, three studies showed female sex as a predictor of poor outcomes, and the other three showed male sex a predictor of poor outcomes. Although RHD is reported to be eradicated in the developed countries, 2.1% of refugees recently screened for RHD in Italy were found to have subclinical RHD. This prevalence is similar to those found in India (2.0%), Cambodia (2.2%) and Mozambique (3%). CONCLUSIONS: There are contradicting results for outcomes after PBMV between males and females. It is not clear whether sex difference plays a role in pathophysiology, diagnosis, management and prognosis of MS. Migration has impacts on epidemiology and management of RHD. Further studies are required in these two fields to explore their relationship to RHD.


Assuntos
Valvuloplastia com Balão , Emigração e Imigração/estatística & dados numéricos , Estenose da Valva Mitral/terapia , Cardiopatia Reumática/terapia , Humanos , Estenose da Valva Mitral/epidemiologia , Cardiopatia Reumática/epidemiologia , Fatores Sexuais
6.
Echocardiography ; 37(8): 1159-1163, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32686863

RESUMO

OBJECTIVE: The objective of the study was to evaluate the accuracy of the mitral leaflet separation index (MLSI) in selected patients with mitral stenosis, before and after percutaneous balloon mitral valvuloplasty (PBMV), compared to conventional methods with transthoracic echocardiography [TTE]. METHODS: A prospective study was conducted in 30 patients, ages 20-60 years, with severe symptomatic mitral stenosis (MS) who had PBMV in the Cardiology Department, Zagazig University and National Heart Institute. A mean of three to five measurements of MLSI was taken in diastole in the parasternal long-axis and apical four-chamber views. The MLSI was re-measured 24-48 hours after PBMV. We calculated the correlation of the MLSI, pre and post BMV, with two-dimensional (2D) MV planimetry and pressure half-time (PHT) methods to assess MVA. RESULTS: There was a positive, highly significant correlation between pre PBMV 2D planimetry and MLSI (r = .665, P-value < .001) as well as post PBMV 2D planimetry and MLSI (r = .410, P-value = .025). A positive highly significant correlation was also noted between pre PBMV PHT and MLSI (r = .678, P-value <.001) and between post PBMV PHT and MLSI (r = .706, P-value <.001). CONCLUSION: Mitral leaflet separation index is an easy and reliable measurement for the assessment of mitral stenosis before and after PBMV.


Assuntos
Valvuloplastia com Balão , Estenose da Valva Mitral , Adulto , Ecocardiografia , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Adulto Jovem
7.
Circ Cardiovasc Qual Outcomes ; 13(4): e006127, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32252549

RESUMO

BACKGROUND: Fetal aortic valvuloplasty (FAV) may prevent progression of midgestation aortic stenosis to hypoplastic left heart syndrome. However, FAV has well-established risks, and its survival benefit remains unknown. Our primary aim was to determine whether FAV for midgestation aortic stenosis increases survival from fetal diagnosis to age 6 years. METHODS AND RESULTS: We performed a retrospective analysis of 143 fetuses who underwent FAV from 2000 to 2017 and a secondary analysis of the Pediatric Heart Network Single Ventricle Reconstruction trial. Using these results, we developed a decision model to estimate probability of transplant-free survival from fetal diagnosis to age 6 years and postnatal restricted mean transplant-free survival time. FAV was technically successful in 84% of 143 fetuses with fetal demise in 8%. Biventricular circulation was achieved in 50% of 111 live-born infants with successful FAV but in only 16% of the 19 patients with unsuccessful FAV. The model projected overlapping probabilities of transplant-free survival to age 6 years at 75% (95% CI, 67%-82%) with FAV versus 72% (95% CI, 61%-82%) with expectant fetal management, resulting in a restricted mean transplant-free survival time benefit of 1.2 months. When limiting analyses to the improved FAV experience since 2009 to reflect current practice, (probability of technical success [94%], fetal demise [4%], and biventricular circulation [66%]), the model projected that FAV increased the probability of survival to age 6 years to 82% (95% CI, 73%-89%). Expectant management is favored if risk of fetal demise exceeded 12% or probability of biventricular circulation fell below 26%, but FAV remained favored over plausible recent range of technical success. CONCLUSIONS: Our model suggests that FAV provides a modest, medium-term survival benefit over expectant fetal management. Appropriate patient selection and low risk of fetal demise with FAV are critical factors for obtaining a survival benefit.


Assuntos
Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão , Regras de Decisão Clínica , Árvores de Decisões , Terapias Fetais , Síndrome do Coração Esquerdo Hipoplásico/terapia , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Criança , Pré-Escolar , Tomada de Decisão Clínica , Ensaios Clínicos como Assunto , Progressão da Doença , Feminino , Terapias Fetais/efeitos adversos , Terapias Fetais/mortalidade , Idade Gestacional , Transplante de Coração , Humanos , Síndrome do Coração Esquerdo Hipoplásico/mortalidade , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Lactente , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Acta Radiol ; 61(9): 1176-1185, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31937108

RESUMO

BACKGROUND: The experience with cardiac magnetic resonance (CMR) in mitral stenosis (MS) is limited in contrast to mitral regurgitation. PURPOSE: To compare CMR versus 2D and 3D transthoracic (TTE) and 3D transesophgeal (TEE) echocardiography in assessment of rheumatic MS before and after percutaneous balloon mitral valvuloplasty (PBMV). MATERIAL AND METHODS: Twenty consecutive symptomatic patients with MS were evaluated prospectively and independently by CMR, TTE, and TEE pre-PBMV, and by CMR and TTE post-PBMV. Mitral valve area (MVA) was assessed by CMR planimetry, TTE and TEE planimetry, and pressure half time (PHT). Further assessment included trans-mitral velocity, mitral regurgitation (MR), and left atrial (LA) volume. RESULTS: PBMV was successful in 18 patients and failed in two patients (one with MVA <1.5 cm2, one developed severe MR). Pre-PBMV and MVA by CMR, 2D TTE, biplane, 3D TTE, 3D TEE, and PHT were 1.16, 1.16, 1.10, 1.02, 1.05, and 0.99 cm2, respectively. Post-PBMV, a significant increase in MVA was observed (2.15, 2.06, 2.07, 2.04, and 2.03 cm2, respectively). High agreement was observed between CMR and echocardiography before and after PBMV, except for PHT method. CMR significantly underestimated trans-mitral velocity and gradients compared to echocardiography (P<0.001). Before PBMV, mild MR was observed in 11, 12, and 19 patients by 2D TTE, 3D TTE, and CMR. After PBMV, MR was observed in all patients (19 mild, one severe) by all modalities. Echocardiography significantly underestimated LA volume compared to CMR (P<0.001). LA volume decreased significantly after PBMV (P<0.001). CONCLUSION: CMR provides comprehensive assessment of several parameters in MS patients before and after intervention. Agreement with echocardiography is acceptable.


Assuntos
Valvuloplastia com Balão , Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Adulto , Ecocardiografia Tridimensional , Eletrocardiografia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Estudos Prospectivos
9.
Circ J ; 84(2): 269-276, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31902829

RESUMO

BACKGROUND: Cardiac conduction disturbance (CD) is the most frequent complication following transcatheter aortic valve replacement (TAVR). This study examined whether the anatomy of the membranous septum (MS) could provide useful information about the risk of CD following TAVR with a balloon-expandable valve (BEV).Methods and Results:Among 132 consecutive patients, 106 (mean age, 85.6±5.1 years; 75 females) were included in the study. Using preoperative CT and angiography, MS length and implantation depth (ID) were assessed. The MS length minus the prosthesis ID was calculated (∆MSID). Correlation between CD, defined as new-onset left-bundle branch block (LBBB) or the need for permanent pacemaker (PPM) within 1 week after the procedure, and MS length were evaluated. A total of 19 patients (18%) developed CD following TAVR. MS length was significantly shorter in these patients than in those without CD (5.3±1.3 vs. 6.6±1.4; P<0.001), and was the important predictor of CD (odds ratio [OR]: 0.43, 95% confidence interval [CI]: 0.27-0.69, P<0.001). When considering the pre- and postprocedural parameters, the ∆MSID was smaller in patients with CD (-1.7±1.5 vs. 0.8±1.9, P<0.001), and emerged as the important predictor of CD (OR: 0.47, 95% CI: 0.33-0.69, P<0.001). CONCLUSIONS: Short MS is associated with an increased risk of CD after TAVR with BEV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Bloqueio de Ramo/etiologia , Angiografia por Tomografia Computadorizada , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Septo Interventricular/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Septo Interventricular/fisiopatologia
10.
Int J Cardiovasc Imaging ; 35(8): 1453-1463, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30937683

RESUMO

To compare contrast-enhanced magnetic resonance angiography (ceMRA) and 3D steady-state free precession (SSFP) during systole and diastole for assessment of the right ventricle outflow tract (RVOT) in patients considered for percutaneous pulmonary valve implantation (PPVI) after tetralogy of Fallot (TOF) repair. We retrospectively evaluated 89 patients (male: 45, mean age 19 ± 8 years), who underwent cardiac-MRI after surgical TOF-repair. Datasets covering the whole heart in systole and diastole were acquired using ECG-gated 3D SSFP and non-gated ceMRA. Measurements were performed in SSFP-sequences and in ceMRA in the narrowest region of the RVOT to obtain the minimum, maximum and effective diameter. Invasive balloon sizing as the gold standard was available in 12 patients. The minimum diameter in diastolic SSFP, systolic SSFP and ceMRA were 21.4 mm (± 6.1 mm), 22.6 mm (± 6.2 mm) and 22.6 mm (± 6.0 mm), respectively. Maximum diameter was 29.9 mm (± 9.5 mm), 30.0 mm (± 7.0 mm) and 28.8 mm (± 8.1 mm) respectively. The effective diameter was 23.2 mm (± 5.7 mm), 27.4 mm (± 6.7 mm) and 24.4 mm (± 6.2 mm), differing significantly between diastole and systole (p < 0.0001). Measurements in ECG-gated SSFP showed a better inter- and intraobserver variability compared to measurements in non-ECG-gated ceMRA. Comparing invasive balloon sizing with our analysis, we found the highest correlation coefficients for the maximum and effective diameter measured in systolic SSFP (R = 0.99 respectively). ECG-gated 3D SSFP enables the identification and characterization of a potential landing zone for PPVI. The maximum and effective systolic diameter allow precise sizing for PPVI. Patients with TOF-repair could benefit from cardiac MRI before PPVI.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Valvuloplastia com Balão , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Técnicas de Imagem de Sincronização Cardíaca , Criança , Meios de Contraste/administração & dosagem , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/etiologia , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento , Função Ventricular Direita , Adulto Jovem
11.
Circ Cardiovasc Interv ; 12(4): e007597, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30998397

RESUMO

BACKGROUND: The durability of transcatheter aortic bioprosthetic valves is a crucial issue, but data are scarce, especially beyond 5 years of follow-up. We aimed to assess long-term (7 years) structural valve deterioration (SVD) and bioprosthetic valve failure of transcatheter aortic bioprosthetic valves. METHODS AND RESULTS: Consecutive patients with at least 5-year follow-up available undergoing transcatheter aortic valve implantation from April 2002 to December 2011 in 5 French centers were included. Incidence of SVD and bioprosthetic valve failure were defined according to newly standardized criteria of the European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery and reported as cumulative incidence function to account for the competing risk of death. One thousand four hundred three consecutive patients were included with a mean age of 82.6±7.5 years and with a mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) of 21.3±7.5%. A balloon-expandable valve was used in 83.7% of cases. Survival rates were 83.5% (95% CI, 81.4%-85.5%) and 18.6% (95% CI, 15.3%-21.8%) at 1 and 7 years, respectively. Median duration of follow-up was 3.9 years. Bioprosthetic valve failure occurred in 19 patients with a 7-year cumulative incidence of 1.9% (95% CI, 1.4%-2.4%). SVD occurred in 49 patients (moderate, n=32; severe, n=17) with a 7-year cumulative incidence of moderate and severe SVD of 7.0% (95% CI, 5.6%-8.4%) and 4.2% (95% CI, 2.9%-5.5%), respectively. Five patients had aortic valve reintervention (1.0%; 95% CI, 0.4%-1.6%) including 1 case of surgical aortic valve replacement and 4 redo-transcatheter aortic valve implantation. The incidences of SVD and bioprosthetic valve failure were not significantly different between balloon and self-expandable prostheses. CONCLUSIONS: The long-term assessment of transcatheter aortic bioprosthetic valves durability is limited by the poor survival of our population beyond 5 years. Further studies are warranted, particularly in younger and lower-risk patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
JACC Cardiovasc Imaging ; 12(1): 25-34, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29909110

RESUMO

OBJECTIVES: This study aims to establish parameters for identifying normal function for each of the 3 iterations of balloon-expandable valves and 2 iterations of self-expanding valves. BACKGROUND: Expected transthoracic echocardiographic Doppler-derived hemodynamic data for transcatheter aortic valves inform pre-implant decision-making and post-implanted monitoring of longitudinal valve function. METHODS: We collected the echocardiography core Lab measured mean gradients and effective orifice area (EOA) from discharge or 30-day echocardiograms from randomized trials; the PARTNER (Placement of Aortic Transcatheter Valves) trials for the balloon-expandable valves and the Medtronic CoreValve US Pivotal trial and Medtronic CoreValve Evolut R United States IDE Clinical Study for the self-expanding valves. RESULTS: For all SAPIEN (Edwards Lifesciences, Irvine, California) valve sizes, mean EOA is 1.70 ± 0.49 cm2 with a mean gradient of 9.36 ± 4.13 mm Hg. For all SAPIEN XT valve sizes, mean EOA is 1.67 ± 0.46 cm2 with a mean gradient of 9.52 ± 3.64 mm Hg. For all SAPIEN 3 valve sizes, the mean EOA is 1.66 ± 0.38 cm2 with a mean gradient of 11.18 ± 4.35 mm Hg. For all CoreValve valve sizes, the mean EOA is 1.88 ± 0.56 cm2 with a mean gradient of 8.85 ± 4.14 mm Hg. For all Evolut R valve sizes, the mean EOA is 2.01 ± 0.65 cm2 with a mean gradient of 7.52 ± 3.19 mm Hg. The SAPIEN 3 post-implant EOA was progressively larger for each quintile of baseline annular area by computed tomography (p < 0.001). Similarly, for the Evolut R valve, post-implantation EOA was significantly larger for each quintile of baseline annular perimeter (p < 0.001). CONCLUSIONS: Tables of expected mean transcatheter aortic valve hemodynamics by valve type and size are essential in evaluating the function of these transcatheter prosthetic valves. Tables of expected EOA by the native annular anatomy may be useful for pre-implantation decision making. Criteria for defining structural valve dysfunction are proposed.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Bioprótese , Ecocardiografia Doppler , Próteses Valvulares Cardíacas , Hemodinâmica , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Humanos , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Indian Heart J ; 71(6): 454-458, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32248917

RESUMO

OBJECTIVE: Percutaneous mitral valvuloplasty (PMV) is an effective treatment for patients with mitral valve stenosis. Echocardiographic score (ES) is a useful predictor of outcomes. However, mitral valve calcification (MVC) has been shown to predict immediate results even in patients with otherwise low ES. We sought to evaluate the usefulness of MVC assessment as a predictor of immediate and long-term outcomes after PMV. METHODS: PMV was performed in 168 consecutive patients. Clinical and echocardiographic variables were analyzed. Patients were classified into 2 groups: group 1: minimal MVC and group 2: moderate to severe MVC. Primary success was defined as post-PMV mitral valve area (MVA) ≥ 1.5 cm2 in the absence of major complications. Restenosis (RE) was defined as a decrease in MVA >50% of initial gain or a final MVA <1.5 cm2. RESULTS: Mean age was 46.5 ± 11 years, and 86.9% (146) were women. Forty-two patients (25%) had mild MVC (group 1), and 75% of the patients had moderate to severe MVC (group 2). Procedural success was achieved in 95.2% and 76.2% for groups 1 and 2, respectively, p = 0.01. MVA after PMV was 1.82 cm2 (IQR 25-75 = 1.60-2.00) in group 1 and 1.67 cm2 (IQR 25-75 = 1.44-1.97) in group 2, p = 0.02. After 48 months, 28.2% of patients presented RE. Multivariate analysis identified the presence of MVC as an independent predictor of poor immediate results (HR = 0.12, 95% IC 0.03-0.91) and RE (HR = 1.94, 95% CI = 1.02-5.21). CONCLUSION: Our study shows that the presence of MVC may predict immediate and long-term outcomes after PMV.


Assuntos
Valvuloplastia com Balão , Calcinose/diagnóstico por imagem , Estenose da Valva Mitral/terapia , Valva Mitral/diagnóstico por imagem , Adulto , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Mymensingh Med J ; 27(4): 851-858, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30487504

RESUMO

Mitral stenosis (MS) affects left atrial (LA) function as a result of hemodynamic and myocardial factors that causes significant symptoms and complications. Conventional echocardiographic methods have been practicing to see the improvement of left atrial function after successful percutaneous mitral balloon valvuloplasty (PMBV). Introduction of tissue doppler imaging allows direct and non-invasive measurement of myocardial velocities. The aim of the study was to evaluate LA functions after PMBV using colour tissue doppler imaging. This cross sectional study was performed in Cardiology department of Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh from March 2014 to February 2015. Forty six (46) patients (28 females, mean age: 28.96±5.78 years) presenting with mitral valve stenosis who fulfilled the indications for PMBV were included in the study. Within 24 hours before PMBV, all the patients underwent colour tissue doppler study in addition to routine conventional echocardiographic examinations. Late diastolic velocities (A') measured at the septal and lateral annuli were recorded. All the measurements were repeated 24 hours after PMBV. The PMBV was done using the Inoue technique. After PMBV mitral valve areas (MVA) were significantly increased. Maximum and mean gradients, LA diameter, LA area, LA volume, systolic pulmonary arterial pressure and mean LA pressures were decreased while septal and lateral A' were significantly (p<0.001) increased. Lateral and septal A' velocities were correlated with MVA and inversely related to LA pressure measured invasively during PMBV. Tissue doppler velocities illustrated improvement of left atrial systolic function after PMBV in relation to decreased mean left atrial pressure and increased mitral valve area. Therefore, tissue doppler Imaging is a useful tool to detect improvement of left atrial systolic function after PMBV in patients with mitral stenosis.


Assuntos
Valvuloplastia com Balão , Estenose da Valva Mitral , Adulto , Função do Átrio Esquerdo , Bangladesh , Estudos Transversais , Ecocardiografia , Feminino , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Adulto Jovem
15.
Circ Cardiovasc Imaging ; 11(3): e006708, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29555832

RESUMO

BACKGROUND: Aortic stenosis has been reported to manifest a slow rate of progression in mild disease, with a greater likelihood of progression in patients with moderate-severe disease. The natural history of the Doppler-estimated maximum gradient (DEMG) in patients after balloon aortic valvuloplasty (BAVP) has not previously been studied on a large scale. METHODS AND RESULTS: A retrospective review was performed of 360 patients from 1984 to 2012 with aortic stenosis, providing a total of 2059 echocardiograms both before and after BAVP. Patients were excluded if they had an intervention within the first 30 days of life. The relationships between the aortic stenosis DEMG and several predictors (age at initial study, body surface area, valve morphology, and initial DEMG) were explored using linear mixed effect models. Patients with a unicommissural aortic valve had a significantly higher rate of progression compared with those with a bicommissural aortic valve (0.81 and 0.45 mm Hg/year; P<0.001). The median rate of progression in the post-BAVP group was significantly lower than the median pre-BAVP rate of progression (n=34; pre-BAVP 3.97 [1.69-8.7] mm Hg/year; post-BAVP 0.40 [-1.80 to 3.88] mm Hg/year; P<0.008). When adjusted for body surface area, there was no significant increase in the DEMG (-0.03 mm Hg/m2 per year; P<0.001). CONCLUSIONS: There is a statistically significant increase in the DEMG over time in patients with aortic stenosis. After balloon dilation, the DEMG rate of change is reduced compared with that pre-dilation. Given the effect of body surface area on DEMG progression, more frequent observation should be made during periods of rapid somatic growth.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valvuloplastia com Balão/métodos , Ecocardiografia Doppler/métodos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico , Criança , Pré-Escolar , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Período Pós-Operatório , Período Pré-Operatório , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
17.
Catheter Cardiovasc Interv ; 91(5): 986-994, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29399947

RESUMO

OBJECTIVES: To explore assessment of supra-annular structure for self-expanding transcatheter heart valve (THV) size selection in patients with bicuspid aortic stenosis (AS). BACKGROUND: Annulus-based device selection from CT measurement is the standard sizing strategy for tricuspid aortic valve before transcatheter aortic valve replacement (TAVR). Because of supra-annular deformity, device selection for bicuspid AS has not been systemically studied. METHODS: Twelve patients with bicuspid AS who underwent TAVR with self-expanding THVs were included in this study. To assess supra-annular structure, sequential balloon aortic valvuloplasty was performed in every 2 mm increments until waist sign occurred with less than mild regurgitation. Procedural results and 30 day follow-up outcomes were analyzed. RESULTS: Seven patients (58.3%) with 18 mm; three patients (25%) with sequential 18 mm, 20 mm; and only two patients (16.7%) with sequential 18 mm, 20 mm, and 22 mm balloon sizing were performed, respectively. According to the results of supra-annular assessment, a smaller device size (91.7%) was selected in all but one patient compared with annulus based sizing strategy, and the outcomes were satisfactory with 100% procedural success. No mortality and 1 minor stroke were observed at 30 d follow-up. The percentage of NYHA III/IV decreased from 83.3% (9/12) to 16.7% (2/12). No new permanent pacemaker implantation and no moderate or severe paravalvular leakage were found. CONCLUSIONS: A supra-annular structure based sizing strategy is feasible for TAVR in patients with bicuspid AS.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Tomada de Decisão Clínica , Ecocardiografia , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
Cardiovasc Revasc Med ; 19(5 Pt B): 626-631, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29352699

RESUMO

OBJECTIVES: The lower limit of the membranous septum (MS) is considered an anatomic landmark for the emergence of the Bundle of His into the left ventricle. Computed tomography (CT) assessment of MS anatomy may provide useful information about the risk of conduction abnormalities following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: The study included 102 consecutive patients undergoing TAVR with the Edwards Sapien 3 (S3) valve. Using pre-TAVR CT and post-procedure angiography we evaluated for the presence of calcium in the left ventricular outflow tract (LVOT), calcium depth (CD), implantation depth (ID) and MS length. The MS length minus the prosthesis ID was calculated (Delta MSID). Outcomes included new left bundle branch block (LBBB) or permanent pacemaker (PPM) within 30days. Seventeen patients (17%) received a PPM and 28 (27%) developed new LBBB following TAVR. Mean (±SD) MS length and delta MSID were 7.5mm (2) and 0.9mm (4.5), respectively. Twenty-one patients (20%) had calcium in the device landing zone and the mean (SD) CD was 6.8mm (±4). Calcium in the device landing zone (37% versus 16%, p=0.02) and implantation depth (6mm (4-8) versus 4mm (4-5), p=0.02) predicted new conduction abnormalities after TAVR. CONCLUSIONS: The presence of calcium in the device landing zone is associated with increased risk of conduction abnormalities after TAVR with S3. In such cases, a more aortic deployment of the prosthesis may be warranted.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aortografia/métodos , Valvuloplastia com Balão , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Septos Cardíacos/diagnóstico por imagem , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Valvuloplastia com Balão/efeitos adversos , Cálcio/análise , Estimulação Cardíaca Artificial , Tomada de Decisão Clínica , Eletrocardiografia , Feminino , Septos Cardíacos/química , Humanos , Masculino , Marca-Passo Artificial , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
Artigo em Inglês | MEDLINE | ID: mdl-27301396

RESUMO

BACKGROUND: Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets for implantation that would improve hemodynamics after ViV. METHODS AND RESULTS: Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated postprocedural gradients (mean ≥20 mm Hg). Optimal implantation depths were defined by receiver operating characteristic curve. A total of 292 consecutive patients (age, 78.9±8.7 years; 60.3% male; 157 CoreValve Evolut and 135 Sapien XT) were evaluated. High implantation was associated with significantly lower rates of elevated gradients in comparison with low implantation (CoreValve Evolut, 15% versus 34.2%; P=0.03 and Sapien XT, 18.5% versus 43.5%; P=0.03, respectively). Optimal implantation depths were defined: CoreValve Evolut, 0 to 5 mm; Sapien XT, 0 to 2 mm (0-10% frame height); sensitivities, 91.3% and 88.5%, respectively. The strongest independent correlate for elevated gradients after ViV was device position (high: odds ratio, 0.22; confidence interval, 0.1-0.52; P=0.001), in addition to type of device used (CoreValve Evolut: odds ratio, 0.5; confidence interval, 0.28-0.88; P=0.02) and surgical valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). CONCLUSIONS: High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self- and balloon-expandable transcatheter valves. These clinical evaluations support specific implantation targets to optimize hemodynamics after ViV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Distribuição de Qui-Quadrado , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Curr Probl Cardiol ; 40(11): 483-503, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26471206

RESUMO

Managing the risk of noncardiac surgery in patients with aortic stenosis is a problem that is frequently confronted in clinical practice. Traditionally, patients with severe aortic stenosis were considered to be at substantial risk during noncardiac surgery, and as such, elective procedures were avoided before intervention on the aortic valve in most patients other than those who were ineligible or refused aortic valve replacement. Recent data suggest that with contemporary anesthesia and surgical techniques, the risk of noncardiac surgery is substantially lower than previously believed. We review the existent literature in the field, and propose a practical approach to complex patients.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/terapia , Gestão de Riscos/métodos , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Algoritmos , Anestesia/métodos , Valvuloplastia com Balão , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Monitorização Intraoperatória/métodos , Assistência Perioperatória/métodos , Procedimentos Cirúrgicos Operatórios/métodos , Procedimentos Cirúrgicos Operatórios/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA