Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 396
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(6): 873-884, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38558510

RESUMO

BACKGROUND: Quantitative flow ratio (QFR) and myocardial perfusion scintigraphy (MPS) are utilized for assessing coronary artery disease (CAD) significance. We aimed to analyze their concordance and prognostic impact. AIMS: We aimed to analyze the concordance between QFR and MPS and their risk stratification. METHODS: Patients with invasive coronary angiography and MPS were categorized as concordant if QFR ≤ 0.80 and summed difference score (SDS) ≥ 4 or if QFR > 0.80 and SDS < 4; otherwise, they were discordant. Concordance was classified by coronary territory involvement: total (three territories), partial (two territories), poor (one territory), and total discordance (zero territories). Leaman score assessed coronary atherosclerotic burden. RESULTS: 2010 coronary territories (670 patients) underwent joint QFR and MPS analysis. MPS area under the curve for QFR ≤ 0.80 was 0.637. Concordance rates were total (52.5%), partial (29.1%), poor (15.8%), and total discordance (2.6%). Most concordance occurred in patients without significant CAD or with single-vessel disease (89.5%), particularly without MPS perfusion defects (91.5%). Leaman score (odds ratio [OR]: 0.839, 95% confidence interval [CI]: 0.805-0.875, p < 0.001) and MPS perfusion defect (summed stress score [SSS] ≥ 4) (OR: 0.355, 95% CI: 0.211-0.596, p < 0.001) were independent predictors for discordance. After 1400 days, no significant difference in death/myocardial infarction was observed based on MPS assessment, but Leaman score, functional Leaman score, and average QFR identified higher risk patients. CONCLUSIONS: MPS showed good overall accuracy in assessing QFR significance but substantial discordance existed. Predictors for discordance included higher atherosclerotic burden and MPS perfusion defects (SSS ≥ 4). Leaman score, QFR-based functional Leaman score, and average QFR provided better risk stratification for all-cause death and myocardial infarction than MPS.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Humanos , Imagem de Perfusão do Miocárdio/métodos , Feminino , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/mortalidade , Pessoa de Meia-Idade , Idoso , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Reprodutibilidade dos Testes , Circulação Coronária , Índice de Gravidade de Doença , Tomografia Computadorizada de Emissão de Fóton Único , Reserva Fracionada de Fluxo Miocárdico , Fatores de Tempo
2.
J Am Coll Cardiol ; 78(22): 2196-2212, 2021 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-34823663

RESUMO

Myocardial bridging (MB) is a congenital coronary anomaly in which a segment of the epicardial coronary artery traverses through the myocardium for a portion of its length. The muscle overlying the artery is termed a myocardial bridge, and the intramyocardial segment is referred to as a tunneled artery. MB can occur in any coronary artery, although is most commonly seen in the left anterior descending artery. Although traditionally considered benign in nature, increasing attention is being given to specific subsets of MB associated with ischemic symptomatology. The advent of contemporary functional and anatomic imaging modalities, both invasive and noninvasive, have dramatically improved our understanding of dynamic pathophysiology associated with MBs. This review provides a contemporary overview of epidemiology, pathobiology, diagnosis, functional assessment, and management of MBs.


Assuntos
Angiografia Coronária/métodos , Circulação Coronária/fisiologia , Vasos Coronários/diagnóstico por imagem , Gerenciamento Clínico , Ponte Miocárdica/diagnóstico , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/fisiopatologia , Humanos , Ponte Miocárdica/fisiopatologia , Ponte Miocárdica/terapia , Ultrassonografia de Intervenção
3.
Open Heart ; 8(2)2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34341096

RESUMO

OBJECTIVES: We sought to evaluate the physiology of non-culprit lesions by using vessel fractional flow reserve (vFFR) among patients with ST elevation myocardial infarction (STEMI) and multivessel disease (MVD). METHODS: From January 2017 to December 2019, 354 patients with STEMI in the Taipei Veterans General Hospital Acute Myocardial Infarction Registry were screened. Patients who underwent successful primary percutaneous coronary intervention (PCI) for culprit lesions, with at least one non-culprit lesion with stenosis of ≥50%, were eligible. vFFR was computed retrospectively. RESULTS: A total of 156 patients with 217 non-culprit lesions were eligible for this study. Aortic root pressure and two good angiograms were available for 139 non-culprit lesions for vFFR analysis. Based on the vFFR analysis, 59 non-culprit lesions (43.2%) had a vFFR value >0.80, and PCI was deferred in 45 lesions (76.3%). Meanwhile, 80 non-culprit lesions (56.8%) had a vFFR value ≤0.80; however, PCI was only performed in 31 lesions (38.7%) (p=0.142). The incidence of vessel-oriented composite endpoint was numerically higher in non-culprit lesions with vFFR ≤0.80 than those with vFFR >0.80 (6.3% vs 1.7%, HR: 3.59, 95% CI: 0.42 to 30.8, p=0.243). CONCLUSION: Functional incomplete revascularisation is common among patients with STEMI and MVD. The adoption of vFFR to assess non-culprit lesions may reclassify the coronary revascularisation strategy that is usually guided by angiography only in this acute setting.


Assuntos
Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Idoso , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Fatores de Tempo
4.
J Interv Cardiol ; 2021: 9971874, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34149324

RESUMO

BACKGROUND: To validate a simplified invasive method for the calculation of the index of microvascular resistance (IMR). METHODS: This is a prospective, single-center study of patients with chronic coronary syndromes presenting with nonobstructive coronary artery disease. IMR was obtained using both intravenous (IV) adenosine and intracoronary (IC) papaverine. Each IMR measurement was obtained in duplicate. The primary objective was the agreement between IMR acquired using adenosine and papaverine. Secondary objectives include reproducibility of IMR and time required for the IMR measurement. RESULTS: One hundred and sixteen IMR measurements were performed in 29 patients. The mean age was 68.8 ± 7.24 years, and 27.6% was diabetics. IMR values were similar between papaverine and adenosine (17.7 ± 7.26 and 20.1 ± 8.6, p=0.25; Passing-Bablok coefficient A 0.58, 95% CI -2.42 to 3.53; coefficient B 0.90, 95% CI -0.74 to 1.07). The reproducibility of IMR was excellent with both adenosine and papaverine (ICC 0.78, 95% CI 0.63 to 0.88 and ICC 0.93, 95% CI 0.87 to 0.97). The time needed for microvascular assessment was significantly shortened by the use of IC papaverine (3.23 (2.84, 3.78) mins vs. 5.48 (4.94, 7.09) mins, p < 0.0001). CONCLUSION: IMR can be reliably measured using IC papaverine with similar results compared to intravenous infusion of adenosine with increased reproducibility and reduced procedural time. This approach simplifies the invasive assessment of the coronary microcirculation in the catheterization laboratory.


Assuntos
Cateterismo Cardíaco , Doença da Artéria Coronariana , Microcirculação/fisiologia , Duração da Cirurgia , Resistência Vascular/fisiologia , Idoso , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Simplificação do Trabalho
5.
Sci Rep ; 11(1): 12680, 2021 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-34135399

RESUMO

Numerical simulations of coupled hemodynamics and leukocyte transport and adhesion inside coronary arteries have been performed. Realistic artery geometries have been obtained for a set of four patients from intravascular ultrasound and angiography images. The numerical model computes unsteady three-dimensional blood hemodynamics and leukocyte concentration in the blood. Wall-shear stress dependent leukocyte adhesion is also computed through agent-based modeling rules, fully coupled to the hemodynamics and leukocyte transport. Numerical results have a good correlation with clinical data. Regions where high adhesion is predicted by the simulations coincide to a good approximation with artery segments presenting plaque increase, as documented by clinical data from baseline and six-month follow-up exam of the same artery. In addition, it is observed that the artery geometry and, in particular, the tortuosity of the centerline are a primary factor in determining the spatial distribution of wall-shear stress, and of the resulting leukocyte adhesion patterns. Although further work is required to overcome the limitations of the present model and ultimately quantify plaque growth in the simulations, these results are encouraging towards establishing a predictive methodology for atherosclerosis progress.


Assuntos
Adesão Celular , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Hemodinâmica , Leucócitos/fisiologia , Modelos Cardiovasculares , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Estresse Mecânico , Ultrassonografia
6.
Am Heart J ; 239: 19-26, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33992606

RESUMO

Angiography-derived physiological assessment of coronary lesions has emerged as an alternative to wire-based assessment aiming at less-invasiveness and shorter procedural time as well as cost effectiveness in physiology-guided decision making. However, current available image-derived physiology software have limitations including the requirement of multiple projections and are time consuming. METHODS/DESIGN: The ReVEAL iFR (Radiographic imaging Validation and EvALuation for Angio-iFR) trial is a multicenter, multicontinental, validation study which aims to validate the diagnostic accuracy of the Angio-iFR medical software device (Philips, San Diego, US) in patients undergoing angiography for Chronic Coronary Syndrome (CCS). The Angio-iFR will enable operators to predict both the iFR and FFR value within a few seconds from a single projection of cine angiography by using a lumped parameter fluid dynamics model. Approximately 440 patients with at least one de-novo 40% to 90% stenosis by visual angiographic assessment will be enrolled in the study. The primary endpoint is the sensitivity and specificity of the iFR and FFR for a given lesion compared to the corresponding invasive measures. The enrollment started in August 2019, and was completed in March 2021. SUMMARY: The Angio-iFR system has the potential of simplifying physiological evaluation of coronary stenosis compared with available systems, providing estimates of both FFR and iFR. The ReVEAL iFR study will investigate the predictive performance of the novel Angio-iFR software in CCS patients. Ultimately, based on its unique characteristics, the Angio-iFR system may contribute to improve adoption of functional coronary assessment and the workflow in the catheter laboratory.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software/normas , Angiografia Coronária/métodos , Angiografia Coronária/tendências , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Precisão da Medição Dimensional , Humanos , Avaliação de Resultados em Cuidados de Saúde , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
7.
Heart Vessels ; 36(5): 638-645, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33389064

RESUMO

The 4-Fr catheter system is not recommended for invasive functional assessment of coronary artery stenosis, because it tends to distort the aortic waveform. This study aimed to identify the incidence of aortic waveform distortion and a feasible method for correct diagnosis of coronary artery stenosis with a 4-Fr catheter. We retrospectively investigated 178 lesions with intermediate coronary artery stenosis. Non-hyperemic distal coronary artery pressure (Pd) and aortic pressure (Pa) were measured with a 4-Fr diagnostic or 6-Fr guiding catheter before and after saline flush. The mean Pd/mean Pa (Pd/Pa) and instantaneous wave-free ratio (iFR) were calculated before and after flushing. We compared the effect of flushing on the changes in Pd/Pa and iFR between the 4-Fr diagnostic and 6-Fr guiding catheters. Using the 4-Fr diagnostic catheter, there was a significant decrease in incidence of aortic waveform distortion from 42.0% (47 lesions) before flushing to 1.8% (2 lesions) after flushing (p < 0.001); the incidence was only 3.0% before saline flush and decreased to 0% after saline flush when using the 6-Fr guiding catheter. The presence of aortic waveform distortion influenced the iFR when the 4-Fr system was used. Functional measurements with the 4-Fr diagnostic catheter require adequate saline flush to remove the influence of aortic waveform distortion.


Assuntos
Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Curva ROC , Estudos Retrospectivos , Índice de Gravidade de Doença
8.
Coron Artery Dis ; 32(7): 610-617, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33471469

RESUMO

BACKGROUND: Coronary artery perforation (CAP) is an uncommon but serious complication of percutaneous coronary intervention (PCI). The aim of this study was to compare early and late clinical outcomes of CAP in patients with or without acute coronary syndromes (ACS). METHOD: A retrospective review was made of the procedural records of 15 878 patients who underwent PCI at two large tertiary centers between January 2012 and December 2018. A total of 51 (0.32 %) CAP cases were identified. RESULTS: Of the 51 CAP cases, 26 (51.0%) patients had ACS and 25 (49%) patients had stable coronary artery disease (CAD). The major cause of perforation was stenting (43%). Cardiac tamponade was more frequent in the ACS group than stable CAD group (34.6 vs. 8%; P = 0.024). Kaplan-Meier analysis showed that the overall 30-day cardiovascular mortality rate was higher in patients with ACS than stable CAD (23.1 vs. 0%; P = 0.011). At the 3-year follow-up examination, no statistically significant difference was determined between the two groups in respect of all-cause mortality (36.1 vs. 28.4%; P = 0.262). Multivariable Cox regression analysis demonstrated left ventricular ejection fraction (hazard ratio, 0.94; 95% CI, 0.89-0.99; P = 0.033) but not ACS at presentation (hazard ratio, 1.39; 95% CI, 0.37-5.20; P = 0.628) as a predictor of mortality at 3 years. CONCLUSIONS: Early clinical outcomes following CAP, including cardiac tamponade and 30-day cardiovascular mortality, were significantly worse in patients with ACS compared to stable CAD.


Assuntos
Vasos Coronários/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Perfuração Espontânea/etiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/estatística & dados numéricos , Prevalência , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Perfuração Espontânea/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Comput Tomogr ; 15(3): 249-257, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33041249

RESUMO

BACKGROUND: Studies have observed higher incidence of cardiovascular mortality in South Asians (SA), and lower prevalence in East Asians (EA), compared with Caucasians. These observations are not entirely explained by ethnic differences in cardiovascular risk factors and mechanistic factors such as variations in cardiac anatomy and physiology may play a role. This study compared ethnic differences in CT-assessed left ventricular (LV) mass, coronary anatomy and non-invasive fractional flow reserve (FFRCT). METHODS: Three-hundred symptomatic patients (age 59 ± 7.9, male 51%) underwent clinically-mandated CT-coronary-angiography (CTA) were matched for age, gender, BMI and diabetes (100 each ethnicity). Assessment of coronary stenosis, luminal dimensions and vessel dominance was performed by independent observers. LV mass, coronary luminal volume and FFRCT were quantified by blinded core-laboratory. A sub-analysis was performed on patients (n = 187) with normal/minimal disease (0-25% stenosis). RESULTS: Stenosis severity was comparable across ethnic groups. EA demonstrated less left-dominant circulation (2%) compared with SA (8.2%) and Caucasians (10.1%). SA compared with EA and Caucasians demonstrated smallest indexed LV mass, coronary luminal volumes and dimensions. EA compared with Caucasians had comparable indexed LV mass, coronary luminal dimensions and highest luminal volumes. The latter was driven by higher prevalence of right-dominance including larger and longer right posterior left ventricular artery. FFRCT in the left anterior descending artery (LAD) was lowest in SA (0.87) compared with EA (0.89; P = 0.009) and Caucasians (0.89; P < 0.001), with no difference in other vessels. All observed differences were consistent in patients with minimal disease. CONCLUSION: This single-centre study identified significant ethnic differences in CT-assessed LV mass, coronary anatomy and LAD FFRCT. These hypotheses generating results may provide a mechanistic explanation for ethnic differences in cardiovascular outcomes and require validation in larger cohorts.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Idoso , Povo Asiático , Doença da Artéria Coronariana/etnologia , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/etnologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Disparidades nos Níveis de Saúde , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Índice de Gravidade de Doença , Função Ventricular Esquerda , Remodelação Ventricular , População Branca
10.
Heart Vessels ; 36(3): 337-344, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33044621

RESUMO

Coronary spasm is an established cause for angina pectoris. Ethnic differences have been suggested among Asian compared to Caucasian patients regarding prevalence, gender distribution, and angiographic patterns of coronary spasm. The aim of this study was to compare contemporary German and Japanese patients with coronary spasm. Between 2011 and 2015, 149 patients with resting angina and unobstructed coronary arteries with acetylcholine-induced epicardial spasm were enrolled in Stuttgart, Germany (n = 69) and Sendai, Japan (n = 80). All patients underwent intracoronary acetylcholine testing according to a standardized protocol. Comprehensive analysis included type of spasm (focal/diffuse), dose of acetylcholine leading to spasm, and frequency of multivessel spasm. Patients in this study were 61 ± 11 years old, predominantly female (54%), and had normal left ventricular ejection fraction (73 ± 9%). Diffuse spasm was the most prevalent type of spasm (85%) whereas focal spasm was found in the remaining 15% of patients. 31% of patients had multivessel spasm. Comparing the German with the Japanese patients, distribution of spasm type (focal/diffuse, p = 0.19) and frequency of multivessel spasm (p = 0.22) were comparable. Moreover, when Japanese patients were compared with German patients and diffuse spasm with focal spasm patients, respectively, no significant differences were observed regarding the acetylcholine dose required to induce spasm (p = 0.078 and p = 0.46, respectively). In conclusion, diffuse epicardial coronary spasm is the most frequent finding among German and Japanese patients with resting angina, unobstructed coronary arteries, and epicardial spasm on acetylcholine testing. Japanese and German patients share several similarities including comparable types of spasm and frequency of multivessel spasm.


Assuntos
Acetilcolina/administração & dosagem , Vasoespasmo Coronário/epidemiologia , Vasos Coronários/fisiopatologia , Vasoconstrição/efeitos dos fármacos , Função Ventricular Esquerda/efeitos dos fármacos , Angiografia Coronária , Vasoespasmo Coronário/induzido quimicamente , Vasoespasmo Coronário/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/efeitos dos fármacos , Feminino , Alemanha , Humanos , Injeções Intra-Arteriais , Japão , Masculino , Pessoa de Meia-Idade , Prevalência , Volume Sistólico/efeitos dos fármacos , Vasodilatadores/administração & dosagem
11.
AJR Am J Roentgenol ; 216(6): 1492-1499, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32876482

RESUMO

BACKGROUND. For clinical decision making, it was recently recommended that values of fractional flow reserve (FFR) derived from coronary CTA (FFRCT) be measured 1-2 cm distal to the stenosis, given the potential for overestimation of ischemia when FFRCT values at far distal segments are used. Supporting data are, however, lacking. OBJECTIVE. The purpose of the present study was to evaluate the diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis and at more distal locations relative to invasive FFR values. METHODS. FFRCT and invasive FFR values for 365 vessels in 253 patients identified from the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry were prospectively assessed. FFRCT values were measured 1-2 cm distal to the stenosis and at the pressure wire position and far distal segments. The diagnostic accuracy of FFRCT was assessed on the basis of the ROC AUC. The AUC of FFRCT was calculated using FFRCT as an explanatory variable and an invasive FFR of 0.80 or less as the dichotomous dependent variable. RESULTS. The AUC of FFRCT values measured 1-2 cm distal to the stenosis (0.85; 95% CI, 0.80-0.88) was higher (p = .002) than that of FFRCT values measured at far distal segments (0.80; 95% CI, 0.76-0.84) and similar (p = .16) to that of FFRCT values measured at the pressure wire position (0.86; 95% CI, 0.81-0.89). FFRCT values measured 1-2 cm distal to the stenosis and at far distal segments had sensitivity of 87% versus 92% (p = .003), specificity of 73% versus 42% (p < .001), PPV of 75% versus 59% (p < .001), and NPV of 86% versus 85% (p = .72), respectively. Subgroup analyses of lesions of the left anterior descending coronary artery, left circumflex coronary artery, and right coronary artery all showed improved specificity and PPV (all p < .005) for FFRCT values measured 1-2 cm distal to the stenosis compared with values measured at the pressure wire position. However, the AUC was higher for measurements obtained 1-2 cm distal to the stenosis versus those obtained at far distal segments, for left anterior descending coronary artery lesions (p < .001) but not for left circumflex coronary artery lesions (p = .27) or right coronary artery lesions (p = .91). CONCLUSION. The diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis was higher than that of FFRCT values measured at far distal segments and was similar to that of FFRCT values measured at the pressure wire position in evaluating ischemic status, particularly for left anterior descending coronary artery lesions. CLINICAL IMPACT. The present study supports recent recommendations from experts to use FFRCT measured 1-2 cm distal to the stenosis, rather than measurements obtained at far distal segments, in clinical decision making.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
12.
J Cardiovasc Comput Tomogr ; 15(1): 85-87, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32654946

RESUMO

INTRODUCTION: With increasing adoption of CT coronary angiography (CTA) there is increasing demand for cost-effective, small footprint, dedicated cardiac scanners. We compared a state-of-the-art, small footprint dedicated cardiac scanner (DCCT) to a standard multidetector scanner (MDCT). METHODS: The study was a retrospective unblinded single centre study. A total of 800 patients were included, with 400 undergoing a DCCT and MDCT coronary CTA scanning, respectively. Image quality was assessed using a 4-point grading score. Image noise and artifact, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and acceptance rate for CT-derived fractional flow reserve (FFRct) were recorded. RESULTS: Overall image quality was higher in the DCCT group (3.8 ± 0.55 vs 3.6 ± 0.69; p = 0.042). There was no difference in overall image noise (p = 0.131) or artifact (p = 0.295). SNR was superior in the DCCT group (14.2 ± 6.85 vs 11.4 ± 3.32; p < 0.005) as was CNR (12.7 ± 6.77 vs 11.9 ± 3.29; p < 0.005). The heart rate was lower in the DCCT group (56 ± 9.1 vs 59 ± 8.1; p < 0.005). No difference in the dose length product (DLP median 244.53 (IQR 105.6) vs 237.63 (IQR 160.1); p = 0.313) or FFRCT acceptance rate (100 vs 97.7%; p > 0.05) was noted. Independent predictors of excellent quality regardless of scanner type were age (p = 0.011), heart rate <65 bpm (p < 0.005), and body mass index < 35 (p < 0.005). CONCLUSION: A DCCT scanner is capable of image quality similar to modern current generation general purpose CT technology. Such technology appears to be a viable option to serve the increasing demand for CTCA imaging.


Assuntos
Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/instrumentação , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Idoso , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Desenho de Equipamento , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
J Pediatr ; 228: 290-293.e1, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32768467

RESUMO

Myocardial dysfunction and coronary artery dilation have been reported in the acute setting of severe acute respiratory syndrome coronavirus disease-2-related multisystem inflammatory syndrome in children. Through a longitudinal echocardiographic single-center study of 15 children, we report the short-term outcomes of cardiac dysfunction and coronary artery dilation in severe acute respiratory syndrome coronavirus disease-2-related multisystem inflammatory syndrome in children.


Assuntos
COVID-19/complicações , Vasos Coronários/diagnóstico por imagem , Síndrome de Resposta Inflamatória Sistêmica/complicações , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico por imagem , Função Ventricular Esquerda , Adolescente , COVID-19/diagnóstico por imagem , Criança , Pré-Escolar , Vasos Coronários/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Humanos , Inflamação , Estudos Longitudinais , Masculino , Estudos Retrospectivos , Sístole , Disfunção Ventricular Esquerda , Adulto Jovem
14.
Adv Med Sci ; 66(1): 1-5, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33190031

RESUMO

PURPOSE: Quantitative flow ratio (QFR) is a recently developed image-based index for the assessment of borderline coronary artery disease. We sought to investigate a correlation between QFR and instantaneous wave-free ratio (iFR) for the assessment of intermediate coronary stenoses. MATERIALS AND METHODS: Patients with borderline coronary lesions (40-90% by visual assessment) undergoing iFR assessment were enrolled. QFR was derived from a modeled hyperemic flow velocity derived from angiography without adenosine-induced hyperemia. Pressure wire-derived iFR served as the reference. RESULTS: Values of QFR and iFR from 110 vessels with a mean percent diameter stenosis of 44.6 â€‹± â€‹12.0% were compared. Mean iFR was 0.90 â€‹± â€‹0.07 and 38 (34.5%) had iFR ≤0.89. Mean QFR was 0.81 â€‹± â€‹0.10 and 44 (40%) had QFR ≤0.80. A good agreement between QFR and iFR measurements was confirmed with a mean difference of 0.09 (95%CI -0.027 to 0.207) and intraclass correlation coefficient of 0.87 (95%CI 0.81-0.91). The overall diagnostic accuracy (AUC in ROC analysis) of QFR in detecting iFR ≤0.89 was 0.87 (95%CI 0.79-0.93; p â€‹< â€‹0.001). Regarding iFR ≤0.89, the optimal cutoff value of QFR was 0.79 with sensitivity, specificity, and accuracy of 76.3%, 83.3%, and 80.0%, respectively. A 100% sensitivity was observed for a QFR cutoff value of 0.88 and a 100% specificity for a QFR cutoff value of 0.69. CONCLUSIONS: Our study confirmed good QFR diagnostic performance and correlation with iFR for detecting the functional ischemia caused by intermediate lesions in coronary arteries. However, the pressure wire assessment with iFR might be warranted in 2/3 of patients after QFR assessment.


Assuntos
Velocidade do Fluxo Sanguíneo , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Prognóstico , Estudos Prospectivos
15.
J Interv Cardiol ; 2020: 5024971, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33293902

RESUMO

During the last two decades, there has been a sharp increase in both interest and knowledge about the coronary microcirculation. Since these small vessels are not visible by the human eye, physiologic measurements should be used to characterize their function. The invasive methods presently used (coronary flow reserve (CFR) and index of microvascular resistance (IMR)) are operator-dependent and mandate the use of adenosine to induce hyperemia. In recent years, a new thermodilution-based method for measurement of absolute coronary blood flow and microvascular resistance has been proposed and initial procedural problems have been overcome. Presently, the technique is easy to perform using the Rayflow infusion catheter and the Coroventis software. The method is accurate, reproducible, and completely operator-independent. This method has been validated noninvasively against the current golden standard for flow assessment: Positron Emission Tomography-Computed Tomography (PET-CT). In addition, absolute flow and resistance measurements have proved to be safe, both periprocedurally and at long-term follow-up. With an increasing number of studies being performed, this method has great potential for better understanding and quantification of microvascular disease.


Assuntos
Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Microcirculação , Isquemia Miocárdica/diagnóstico , Termodiluição/métodos , Humanos , Reprodutibilidade dos Testes , Resistência Vascular
16.
J Am Heart Assoc ; 9(24): e017729, 2020 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-33283600

RESUMO

Background Global fractional flow reserve (FFR) (ie, the sum of the FFR values in the 3 major coronary arteries) is a physiologic correlate of global atherosclerotic burden. The objective of the present study was to investigate the value of global FFR in predicting long-term clinical outcome of patients with stable coronary artery disease but no ischemia-inducing stenosis. Methods and Results We studied major adverse cardiovascular events (MACEs: all-cause death, myocardial infarction, and any revascularization) after 5 years in 1122 patients without significant stenosis (all FFR >0.80; n=275) or with at least 1 significant stenosis successfully treated by percutaneous coronary intervention (ie, post-percutaneous coronary intervention FFR >0.80; n=847). The patients were stratified into low, mid, or high tertiles of global FFR (≤2.80, 2.80-2.88, and ≥2.88). Patients in the lowest tertile of global FFR showed the highest 5-year MACE rate compared with those in the mid or high tertile of global FFR (27.5% versus 22.0% and 20.9%, respectively; log-rank P=0.040). The higher 5-year MACE rate was mainly driven by a higher rate of revascularization in the low global FFR group (16.4% versus 11.3% and 11.8%, respectively; log-rank P=0.038). In a multivariable model, an increase in global FFR of 0.1 unit was associated with a significant reduction in the rates of MACE (hazard ratio [HR], 0.988; 95% CI, 0.977-0.998; P=0.023), myocardial infarction (HR, 0.982; 95% CI, 0.966-0.998; P=0.032), and revascularization (HR, 0.985; 95% CI, 0.972-0.999; P=0.040). Conclusions Even in the absence of ischemia-producing stenoses, patients with a low global FFR, physiologic correlate of global atherosclerotic burden, present a higher risk of MACE at 5-year follow-up.


Assuntos
Aterosclerose/patologia , Causas de Morte/tendências , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Aterosclerose/complicações , Doenças Cardiovasculares/epidemiologia , Estudos de Casos e Controles , Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Efeitos Psicossociais da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Tempo
17.
J Interv Cardiol ; 2020: 8887369, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33162844

RESUMO

BACKGROUND: The study of coronary microcirculation has gained increasing consideration and importance in cath lab. Despite the increase of evidence, its use still remains very limited. QFR is a novel angio-based approach for the evaluation of coronary stenosis. The aim of our study was to use the QFR assessment in stable patients to recreate the IMR formula and to correlate the result of the two techniques. METHODS: From June 1, 2019, to February 29, 2019, 200 patients with CCS and indication of coronary artery angiography and referred to the cath lab of the University Hospital of Ferrara (Italy) were enrolled. After baseline coronary angiogram, quantitative flow ratio, fractional flow reserve, and index of microcirculatory resistance evaluation were performed. RESULTS: Pearson correlation (r) between angio-based index of microcirculatory resistance (A-IMR) and IMR 0.32 with R 2 = 0.098, P=0.03: McNemar test showed a difference between the two tests of 6.82% with 95% CI from -12.05% to 22.89%, which is not significant (P=0.60). Bland and Altman plot showed a mean difference of 23.3 (from -26.5 to 73.1). Sensitivity, specificity, NPV, and PPV were 70%, 83.3%, 75%, and 70% for A-IMR value >44.2. The area under the ROC curve for A-IMR was 0.76 (95% CI 0.61-0.88, P=0.0003). CONCLUSION: We have validated for the first time the formula of the A-IMR, a tool for the calculation of microvascular resistance which does not require the use of pressure guides and the induction of hyperemia.


Assuntos
Resistência Capilar , Angiografia Coronária/métodos , Estenose Coronária , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico , Idoso , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Humanos , Itália , Masculino , Estudo de Prova de Conceito , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
JACC Cardiovasc Interv ; 13(16): 1847-1864, 2020 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-32819476

RESUMO

Ischemic heart disease secondary to coronary vascular dysfunction causes angina and impairs quality of life and prognosis. About one-half of patients with symptoms and signs of ischemia turn out not to have obstructive coronary artery disease, and coronary vascular dysfunction may be relevant. Adjunctive tests of coronary vasomotion include guidewire-based techniques with adenosine and reactivity testing, typically by intracoronary infusion of acetylcholine. The CorMicA (Coronary Microvascular Angina) trial provided evidence that routine management guided by an interventional diagnostic procedure and stratified therapy improves angina and quality of life in patients with angina but no obstructive coronary artery disease. In this paper, the COVADIS study group provide a comprehensive review of why, how, and when coronary vascular dysfunction should be assessed invasively. They discuss the rationale through a shared understanding of vascular pathophysiology and clinical evidence. They propose a consensus approach to how an interventional diagnostic procedure is performed with focus on practical aspects. Finally, the authors discuss the clinical scenarios in patients with stable and acute coronary syndromes in which measurement of coronary vascular function may be helpful for patient care.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Cateterismo Cardíaco , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Hemodinâmica , Síndrome Coronariana Aguda/fisiopatologia , Síndrome Coronariana Aguda/terapia , Tomada de Decisão Clínica , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/fisiopatologia , Eletrocardiografia , Humanos , Valor Preditivo dos Testes , Prognóstico
19.
Open Heart ; 7(1)2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32467136

RESUMO

AIMS: Patients with de novo chest pain are usually investigated non-invasively. The new UK-National Institute for Health and Care Excellence (NICE) guidelines recommend CT coronary angiography (CTCA) for all patients, while European Society of Cardiology (ESC) recommends functional tests. We sought to compare the clinical utility and perform a cost analysis of these recommendations in two UK centres with different primary investigative strategies. METHODSRESULTS: We compared two groups of patients, group A (n=667) and group B (n=654), with new onset chest pain in two neighbouring National Health Service hospitals, each primarily following either ESC (group A) or NICE (group B) guidance. We assessed the clinical utility of each strategy, including progression to invasive coronary angiography (ICA) and revascularisation. We present a retrospective cost analysis in the context of UK tariff for stress echo (£176), CTCA (£220) and ICA (£1001). Finally, we sought to identify predictors of revascularisation in the whole population.Baseline characteristics in both groups were similar. The progression to ICA was comparable (9.9% vs 12.0%, p=0.377), with similar requirement for revascularisation (4.0% vs 5.0%.; p=0.532). The average cost of investigations per investigated patient was lower in group A (£279.66 vs £325.77), saving £46.11 per patient. The ESC recommended risk score (RS) was found to be the only predictor of revascularisation (OR 1.05, 95% CI 1.04 to 1.06; p<0.001). CONCLUSION: Both NICE and ESC-proposed strategies led to similar rates of ICA and need for revascularisation in discrete, but similar groups of patients. The SE-first approach had a lower overall cost by £46.11 per patient, and the ESC RS was the only variable correlated to revascularisation.


Assuntos
Angina Pectoris/diagnóstico por imagem , Regras de Decisão Clínica , Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Testes de Função Cardíaca/normas , Guias de Prática Clínica como Assunto/normas , Idoso , Angina Pectoris/economia , Angina Pectoris/fisiopatologia , Angina Pectoris/terapia , Doença da Artéria Coronariana/economia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/fisiopatologia , Redução de Custos , Análise Custo-Benefício , Feminino , Custos de Cuidados de Saúde , Fatores de Risco de Doenças Cardíacas , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/economia , Revascularização Miocárdica/normas , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco
20.
Eur Radiol ; 30(10): 5499-5506, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32405749

RESUMO

OBJECTIVE: To assess whether anthropometrics, clinical risk factors, and coronary artery calcium score (CACS) can predict the need of further testing after coronary CT angiography (CTA) due to non-diagnostic image quality and/or the presence of significant stenosis. METHODS: Consecutive patients who underwent coronary CTA due to suspected coronary artery disease (CAD) were included in our retrospective analysis. We used multivariate logistic regression and receiver operating characteristics analysis containing anthropometric factors: body mass index, heart rate, and rhythm irregularity (model 1); and parameters used for pre-test likelihood estimation: age, sex, and type of angina (model 2); and also added total calcium score (model 3) to predict downstream testing. RESULTS: We analyzed 4120 (45.7% female, 57.9 ± 12.1 years) patients. Model 3 significantly outperformed models 1 and 2 (area under the curve, 0.84 [95% CI 0.83-0.86] vs. 0.56 [95% CI 0.54-0.58] and 0.72 [95% CI 0.70-0.74], p < 0.001). For patients with sinus rhythm of 50 bpm, in case of non-specific angina, CACS above 435, 756, and 944; in atypical angina CACS above 381, 702, and 890; and in typical angina CACS above 316, 636, and 824 correspond to 50%, 80%, and 90% probability of further testing, respectively. However, higher heart rates and arrhythmias significantly decrease these cutoffs (p < 0.001). CONCLUSION: CACS significantly increases the ability to identify patients in whom deferral from coronary CTA may be advised as CTA does not lead to a final decision regarding CAD management. Our results provide individualized cutoff values for given probabilities of the need of additional testing, which may facilitate personalized decision-making to perform or defer coronary CTA. KEY POINTS: • Anthropometric parameters on their own are insufficient predictors of downstream testing. Adding parameters of the Diamond and Forrester pre-test likelihood test significantly increases the power of prediction. • Total CACS is the most important independent predictor to identify patients in whom coronary CTA may not be recommended as CTA does not lead to a final decision regarding CAD management. • We determined specific CACS cutoff values based on the probability of downstream testing by angina-, arrhythmia-, and heart rate-based groups of patients to help individualize patient management.


Assuntos
Cálcio/metabolismo , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Adulto , Idoso , Angina Pectoris , Antropometria , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Probabilidade , Curva ROC , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA