1.
Clin Radiol ; 76(6): 471.e9-471.e16, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33637308

RESUMO

AIM: To use a locally designed and simple lower-body negative-pressure (LBNP) device and 1.5 T magnetic resonance imaging (MRI) to demonstrate the ability to assess changes in cardiovascular function during preload reduction. These effects were evaluated on ventricular volumes and great vessel flow in healthy volunteers, for which there are limited published data. MATERIAL AND METHODS: After ethical review, 14 volunteers (mean age 33.9 ± 7 years, mean body mass index [BMI] 23.1 ± 2.5) underwent LBNP prospectively at 0, -5, -10, and -20 mmHg pressure, using a locally designed LBNP box. Expiratory breath-hold biventricular volumes, and free-breathing flow imaging of the ascending aorta and main pulmonary artery were acquired at each level of LBNP. RESULTS: At -5 mmHg, there was no change in aortic flow or left ventricular volumes versus baseline. Right ventricular output (p=0.013) and pulmonary net flow (p=0.026) decreased. At -20 mmHg, aortic and pulmonary net flow (p<0.001) decreased, as were left and right ventricular end diastolic volume (p<0.001) and left and right end systolic volumes (p=0.038 and p=0.003 respectively). CONCLUSIONS: Use of a MRI-compatible LBNP device is feasible to measure changes in ventricular volume and great arterial flow in the same experiment. This may enhance further research into the effects of preload reduction by MRI in a wide range of important cardiovascular pathologies.


Assuntos
Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Pressão Negativa da Região Corporal Inferior/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Volume Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Volume Sistólico/fisiologia
2.
BMC Nephrol ; 21(1): 194, 2020 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-32448178

RESUMO

BACKGROUND: Accurate assessment of volume status to direct dialysis remains a clinical challenge. Despite current attempts at volume-directed dialysis, inadequate dialysis and intradialytic hypotension (IDH) are common occurrences. Peripheral venous waveform analysis has recently been developed as a method to accurately determine intravascular volume status through algorithmic quantification of changes in the waveform that occur at different volume states. A noninvasive method to capture peripheral venous signals is described (Non-Invasive Venous waveform Analysis, NIVA). The objective of this proof-of-concept study was to characterize changes in NIVA signal with dialysis. We hypothesized that there would be a change in signal after dialysis and that the rate of intradialytic change in signal would be predictive of IDH. METHODS: Fifty subjects undergoing inpatient hemodialysis were enrolled. A 10-mm piezoelectric sensor was secured to the middle volar aspect of the wrist on the extremity opposite to the access site. Signals were obtained fifteen minutes before, throughout, and up to fifteen minutes after hemodialysis. Waveforms were analyzed after a fast Fourier transformation and identification of the frequencies corresponding to the cardiac rate, with a NIVA value generated based on the weighted powers of these frequencies. RESULTS: Adequate quality (signal to noise ratio > 20) signals pre- and post- dialysis were obtained in 38 patients (76%). NIVA values were significantly lower at the end of dialysis compared to pre-dialysis levels (1.203 vs 0.868, p < 0.05, n = 38). Only 16 patients had adequate signals for analysis throughout dialysis, but in this small cohort the rate of change in NIVA value was predictive of IDH with a sensitivity of 80% and specificity of 100%. CONCLUSIONS: This observational, proof-of-concept study using a NIVA prototype device suggests that NIVA represents a novel and non-invasive technique that with further development and improvements in signal quality may provide static and continuous measures of volume status to assist with volume directed dialysis and prevent intradialytic hypotension.


Assuntos
Volume Sanguíneo , Hipotensão/etiologia , Monitorização Fisiológica/métodos , Diálise Renal/efeitos adversos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo/fisiologia , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Estudo de Prova de Conceito , Sensibilidade e Especificidade , Razão Sinal-Ruído
3.
Acta Anaesthesiol Scand ; 63(8): 1102-1108, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31119723

RESUMO

BACKGROUND: Expansion of the intravascular compartment is common to treat haemodynamic instability in ICU patients. The most useful and accurate variables to guide and evaluate a fluid challenge remain debated and incompletely investigated resulting in significant variability in practice. The analogue mean systemic pressure has been reported as a measure of the intravascular volume state. METHODS: This is a protocol and statistical analysis plan for a review of the application of an analogue of the mean systemic pressure and the use of derived variables to assess the volume state and volume responsiveness. A pulmonary artery catheter was used in 286 postoperative cardiac surgical patients to monitor cardiac output before and after a fluid bolus in addition to arterial and central venous pressures. With otherwise similar monitoring, echocardiography was used in 540 general ICU patients to determine cardiac outputs and indices related to intravascular filling. The responses to a fluid bolus or the passive leg raising manoeuvre will be investigated using continuous and dichotomous definitions of volume responsiveness. The results will be stratified according to the method of monitoring cardiac output. CONCLUSIONS: This study investigating 2 cohorts that encompass a wide variety of reasons for haemodynamic instability will illustrate the applicability of the analogue mean systemic pressure and derived variables to assess the volume state and responsiveness. The results may guide the rationale and design of interventional studies.


Assuntos
Protocolos Clínicos , Hidratação , Pressão Sanguínea/fisiologia , Volume Sanguíneo/fisiologia , Débito Cardíaco/fisiologia , Estudos de Coortes , Hidratação/métodos , Humanos , Unidades de Terapia Intensiva
4.
Echocardiography ; 35(12): 1922-1925, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30338549

RESUMO

AIM: First, the inferior vena cava dilatation index (DIVC) was measured by ultrasound, and then the reliability of DIVC as an indicator to predict volume responsiveness in patients undergoing mechanical ventilation after pneumonectomy was evaluated. METHODS: Pulse indicator continuous cardiac output (Picco) as gold standard was performed to sedated mechanically ventilated post-pneumonectomy patients in intensive care unit of Nanjing Thoracic Hospital from August 2014 to December 2016. Meanwhile, ultrasound measurement to inferior vena cava (IVC) diameter at the end inspiration (Dmax ) and the end of expiration (Dmin ) was performed. DIVC = (Dmax  - Dmin )/Dmin . Above values were recorded at baseline and then after fluid resuscitation challenge (7 mL/kg hydroxyethyl starch). An increase in cardiac index of more than 15% was used as the standard for fluid responsiveness. Patients were divided into responsive group and non-responsive group. A receiver operating characteristic (ROC) curve was then used to determine the sensitivity and specificity of DIVC in predicting fluid responsiveness after pneumonectomy. RESULTS: Eighteen patients were enrolled. 10 patients were divided into responsive group and eight in non-responsive group. DIVC in responsive group was significantly higher than in non-responsive group (P < 0.01). By setting DIVC ≥ 15% as a measure of fluid responsiveness, sensitivity was 81.8% and specificity was 85.7%. CONCLUSION: DIVC is a reliable indicator of capacity responsiveness in mechanically ventilated post-pneumonectomy patients.


Assuntos
Volume Sanguíneo/fisiologia , Pneumonectomia , Ultrassonografia/métodos , Veia Cava Inferior/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Curva ROC , Respiração Artificial , Estudos Retrospectivos
5.
Diagn Interv Radiol ; 24(3): 139-145, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29770766

RESUMO

PURPOSE: We aimed to evaluate the usefulness of histograms of lung perfused blood volume (HLPBV) based on the presence of pulmonary thromboembolism (PTE) and the pulmonary embolic burden. METHODS: A total of 168 patients (55 males; mean age, 62.9 years) underwent contrast-enhanced dual-energy computed tomography (DECT) between January 1 2012 and October 31 2014. Initial DECT images were three-dimensionally reconstructed, and the HLPBV patterns were divided into three types, including the symmetric type (131 patients, 78.0%), gradual type (25 patients, 14.9%), and asymmetric type (12 patients, 7.1%). RESULTS: Acute PTE was diagnosed in all 12 patients with asymmetric type (100%), 19 of the 25 patients with gradual type (76%) and 24 of the 131 patients with symmetric type (18.3%). HLPBV pattern exhibited correlations with the right/left ventricular diameter ratio (r=0.36, P = 0.007) and CT obstruction index (r=0.63, P < 0.001) in patients with PTEs. When the gradual and asymmetric types were regarded as positive for PTE, the specificity, positive predictive value, negative predictive value, and accuracy were 92.9%, 83.8%, 87.6%, and 81.0%, respectively. CONCLUSION: Histogram-pattern analysis using DECT might be a useful application to diagnose PTE.


Assuntos
Volume Sanguíneo/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste , Interpretação Estatística de Dados , Ecocardiografia/métodos , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Pulmão/irrigação sanguínea , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/patologia , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia
6.
Perfusion ; 33(1_suppl): 51-56, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29788838

RESUMO

INTRODUCTION: Clotting is one of the major causes of mortality and morbidity during extracorporeal membrane oxygenation (ECMO). A large meta-analysis study suggests that 29% of patients require the oxygenator to be replaced during ECMO. As clots usually form in the oxygenator, the oxygenator blood volume (OXBV) decreases over time. The currently used pressure gradient as a predicator of clot formation is unreliable. OBJECTIVE: The aim of this study was to develop and validate ultrasound dilution technology in a quantitative assessment of clotting, using measurements of OXBV. METHODS: OXBV was measured using the ELSA monitor (Transonic Systems Inc., Ithaca, NY, USA) from the transit time of a saline bolus passing through the oxygenator as recorded by a sensor placed after the oxygenator. The accuracy and reproducibility (coefficient of variation [CV]) of OXBV measurement and its independence from ECMO flow was assessed in vitro in lambs and from a clinical data archive. RESULTS: The in vitro accuracy compared with volumetric measurements of OXBV of 22-134 ml at flows of 300-700 ml/min was -0.8±6.6%. For an OXBV of 355 ml at flows of 1020-7000 ml/min, accuracy was -0.4±1.6%. In 88 animal OXBV measurements, the CV was 1.49±1.12%. For an OXBV of 153 (range 42-387 ml), clinical measurements at flow ranged from 210-5960 ml/min, with a CV of 3.20±2.44 %. CONCLUSION: Dilution technology has the ability to accurately and reproducibly assess the clotting process in the oxygenator. Larger studies are needed to establish guidelines for the prediction of imminent clotting and may help to avoid unnecessary circuit changes.


Assuntos
Testes de Coagulação Sanguínea/métodos , Volume Sanguíneo/fisiologia , Oxigenação por Membrana Extracorpórea/métodos , Trombose/etiologia , Animais , Feminino , Humanos , Masculino , Ovinos , Trombose/patologia
7.
J Card Fail ; 24(7): 479-483, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29678727

RESUMO

BACKGROUND: Periodic breathing (PB) is often observed in patients with HF at rest, with sleep and during exercise. However, mechanisms underlying abnormal ventilatory control are not entirely established. METHODS: Eleven subjects with HF (10 males, age = 69 ± 12 y) and 12 age-matched control subjects (8 males, age = 65 ± 9 y) participated in the study. PB was defined as a peak in the 0.003-0.04 Hz frequency range of the flow signal during 6 minutes of awake resting breathing. Thoracic blood volumes (Vt, thorax; Vh, heart; Vp, pulmonary), mean transit times (MTTs), and extravascular lung water (EVLW) were quantified using computerized tomography. RESULTS: PB was observed in 7 subjects with HF and was associated with worse functional status. The HF PB-present group had thoracic blood volumes nearly double those of control and HF PB-absent subjects (volumes reported as mL/m2 body surface area, P values vs control: control = 813 ± 246, HF PB-absent = 822 ± 161 P = .981, HF PB-present = 1579 ± 548 P = .002). PB was associated with longer pulmonary MTT (control = 6.7 ± 1.2 s, HF PB-absent = 6.0 ± 0.8 s, HF PB-present = 8.4 ± 1.6 s; P = .033, HF PB-present vs HF PB-absent). EVLW was not elevated in the PB group. CONCLUSIONS: Subjects with HF and PB at rest have greater centralization of blood volume.


Assuntos
Volume Sanguíneo/fisiologia , Insuficiência Cardíaca/fisiopatologia , Respiração , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Teste de Esforço , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Descanso
8.
Clin Neuroradiol ; 28(4): 493-499, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28589484

RESUMO

PURPOSE: Susceptibility-weighted imaging (SWI) visualizes small cerebral veins with high sensitivity and could, thus, enable quantification of hemodynamics of deep medullary veins. We aimed to evaluate volume changes of deep medullary veins in patients with acute cerebral venous sinus thrombosis (CVST) over time in comparison to healthy controls. METHODS: All magnetic resonance imaging (MRI) experiments were executed at 3 T using a 32-channel head coil. Based on SWI and semiautomatic postprocessing (statistical parametric mapping [SPM8] and ANTs), the volume of deep medullary veins was quantified in 14 patients with acute CVST at baseline and the 6­month follow-up, as well as in 13 healthy controls undergoing repeated MRI examination with an interscan interval of at least 1 month. RESULTS: Deep medullary venous volume change over time was significantly different between healthy controls and patient groups (p < 0.001). Patients with superior sagittal sinus thrombosis (SSST) showed a significant decline from baseline to follow-up measurements (9.8 ± 4.9 ml versus 7.5 ± 4.2 ml; p = 0.02), whereas in patients with transverse sinus thrombosis (TST) and healthy controls no significant volume changes were observable. CONCLUSIONS: Venous volume quantification was feasible and reproducible both in healthy volunteers and in patients. The decrease of venous volume in patients over time represents improvement of venous drainage, reduction of congestion, and normalization of microcirculation due to treatment. Thus, quantification of venous microcirculation could be valuable for estimation of prognosis and guidance of CVST therapy in the future.


Assuntos
Volume Sanguíneo/fisiologia , Veias Cerebrais/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Bulbo/irrigação sanguínea , Trombose dos Seios Intracranianos/diagnóstico por imagem , Doença Aguda , Anticoagulantes/uso terapêutico , Volume Sanguíneo/efeitos dos fármacos , Veias Cerebrais/efeitos dos fármacos , Estudos de Coortes , Estudos de Viabilidade , Feminino , Humanos , Trombose do Seio Lateral/diagnóstico por imagem , Trombose do Seio Lateral/tratamento farmacológico , Modelos Lineares , Estudos Longitudinais , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Trombose do Seio Sagital/diagnóstico por imagem , Trombose do Seio Sagital/tratamento farmacológico , Trombose dos Seios Intracranianos/tratamento farmacológico , Adulto Jovem
9.
Br J Anaesth ; 119(6): 1135-1140, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29028929

RESUMO

Background: The assessment of intravascular volume status remains a challenge for clinicians. Peripheral i.v. analysis (PIVA) is a method for analysing the peripheral venous waveform that has been used to monitor volume status. We present a proof-of-concept study for evaluating the efficacy of PIVA in detecting changes in fluid volume. Methods: We enrolled 37 hospitalized patients undergoing haemodialysis (HD) as a controlled model for intravascular volume loss. Respiratory rate (F0) and pulse rate (F1) frequencies were measured. PIVA signal was obtained by fast Fourier analysis of the venous waveform followed by weighing the magnitude of the amplitude of the pulse rate frequency. PIVA was compared with peripheral venous pressure and standard monitoring of vital signs. Results: Regression analysis showed a linear correlation between volume loss and change in the PIVA signal (R2=0.77). Receiver operator curves demonstrated that the PIVA signal showed an area under the curve of 0.89 for detection of 20 ml kg-1 change in volume. There was no correlation between volume loss and peripheral venous pressure, blood pressure or pulse rate. PIVA-derived pulse rate and respiratory rate were consistent with similar numbers derived from the bio-impedance and electrical signals from the electrocardiogram. Conclusions: PIVA is a minimally invasive, novel modality for detecting changes in fluid volume status, respiratory rate and pulse rate in spontaneously breathing patients with peripheral i.v. cannulas.


Assuntos
Volume Sanguíneo/fisiologia , Cateterismo Periférico/métodos , Diálise Renal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico
10.
J Appl Physiol (1985) ; 123(3): 645-654, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28663373

RESUMO

In this Cores of Reproducibility in Physiology (CORP) article, we present the theory and practical aspects of the carbon monoxide (CO) rebreathing method for the determination of total hemoglobin mass in humans. With CO rebreathing, a small quantity of CO is diluted in O2 and rebreathed for a specified time period, during which most of the CO is absorbed and bound to circulating hemoglobin. The dilution principle then allows calculation of the total number of circulating hemoglobin molecules based on the number of absorbed CO molecules and the resulting changes in the fraction of carboxyhemoglobin in blood. Total hemoglobin mass is derived by multiplication with the molar weight of hemoglobin. CO rebreathing has been used for >100 yr and has undergone steady improvement so that today excellent values in terms of accuracy and precision can be achieved if the methodological precautions are carefully followed.


Assuntos
Monóxido de Carbono/metabolismo , Hemoglobinas/metabolismo , Volume Sanguíneo/fisiologia , Determinação do Volume Sanguíneo/métodos , Carboxihemoglobina/metabolismo , Humanos , Reprodutibilidade dos Testes
11.
J Acad Nutr Diet ; 117(8): 1177-1187, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28571655

RESUMO

BACKGROUND: Accurate prediction of 24-hour energy expenditure (24EE) relies on knowing body composition, in particular fat-free mass (FFM), the largest determinant of 24EE. FFM is closely correlated with hematologic volumes: blood volume (BV), red cell mass (RCM), and plasma volume (PV). However, it is unknown whether predicted hematologic volumes, based on easily collected variables, can improve 24EE prediction. OBJECTIVE: The aim was to develop and validate equations to predict 24EE based on predicted BV, RCM, and PV and to compare the accuracy and agreement with models developed from FFM and with the Mifflin-St Jeor equation, which is recommended for clinical use by the Academy of Nutrition and Dietetics. DESIGN: Participants had body composition measured by underwater weighing and 24EE by respiratory chamber. BV, RCM, and PV were calculated from five published equations. PARTICIPANTS/SETTING: Native American and white men and women were studied (n=351). Participants were healthy adults aged 18 to 49 years from the Phoenix, AZ, metropolitan area. MAIN OUTCOME MEASURE: Accuracy to within ±10% of measured 24EE and agreement by Bland-Altman analysis. STATISTICAL ANALYSIS: Regression models to predict 24EE from hematologic and body composition variables were developed in half the dataset and validated in the other half. RESULTS: Hematologic volumes were all strongly correlated with FFM in both men and women (r≥0.94). Whereas the accuracy of FFM alone was 69%, four hematologic volumes were individually more accurate (75% to 78%) in predicting 24EE. Equations based on hematologic volumes plus demographics had mean prediction errors comparable to those based on body composition plus demographics; although the Mifflin-St Jeor had modestly better mean prediction error, body composition, hematologic, and Mifflin-St Jeor models all had similar accuracy (approximately 80%). CONCLUSIONS: Prediction equations based on hematologic volumes were developed, validated, and found to be comparable to Mifflin-St Jeor and body composition models in this population of healthy adults.


Assuntos
Volume Sanguíneo/fisiologia , Composição Corporal , Metabolismo Energético , Modelos Teóricos , Adiposidade , Adolescente , Adulto , Índice de Massa Corporal , Calorimetria Indireta , Eritrócitos/fisiologia , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
12.
Eur J Radiol ; 90: 34-41, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28583645

RESUMO

PURPOSE: To investigate the feasibility of perfusion-CT (p-CT) measurements in quantitative assessment of hemodynamic changes related to sorafenib in patients with advanced hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Twenty-two patients with advanced HCC underwent p-CT study (256-MDCT scanner) before and 2 months after sorafenib administration. Dedicated perfusion software generated a quantitative map of arterial and portal perfusion and calculated the following perfusion parameters in target liver lesion: hepatic perfusion (HP), time-to-peak (TTP), blood volume (BV), arterial perfusion (AP), and hepatic perfusion index (HPI). After the follow-up scan, patients were categorized as responders and non-responders, according to mRECIST. Perfusion values were analyzed and compared in HCC lesions and in the cirrhotic parenchyma (n=22), such as between baseline and follow-up in progressors and non-progressors. RESULTS: Before treatment, all mean perfusion values were significantly higher in HCC lesions than in the cirrhotic parenchyma (HP 47.8±17.2 vs 13.3±6.3mL/s per 100g; AP 47.9±18.1 vs 12.9±10.7mL/s; p<0.001). The group that responded to sorafenib (n=17) showed a significant reduction of values in HCC target lesions after therapy (HP 29.2±23.3 vs 48.1±15.1; AP 29.4±24.6 vs 49.2±17.4; p<0.01), in comparison with the non-responder group (n=5) that demonstrated no significant variation before and after treatment of HP (46.9±25.1 vs 46.7±24.1) and AP (43.4±21.7 vs 43.5±24.6). Among the responder group, HP percentage variation (Δ) in target lesions, during treatment, showed a significantly different (p=0.04) ΔHP in the group with complete response (79%) compared to the group with partial response or stable disease (16%). CONCLUSIONS: p-CT technique can be used for HCC quantitative assessment of changes related to anti-angiogenic therapy. Identification of response predictors might help clinicians in selection of patients who may benefit from targeted-therapy allowing for optimization of individualized treatment.


Assuntos
Volume Sanguíneo/fisiologia , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Niacinamida/análogos & derivados , Imagem de Perfusão/métodos , Compostos de Fenilureia/farmacologia , Tomografia Computadorizada Espiral/métodos , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/patologia , Estudos de Viabilidade , Humanos , Niacinamida/farmacologia , Sorafenibe
13.
Med Klin Intensivmed Notfmed ; 112(4): 326-333, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-26676240

RESUMO

When treating acutely ill patients in the emergency department (ED), the successful management of a variety of medical conditions, such as sepsis, acute kidney injury, and pancreatitis, is highly dependent on the correct assessment and optimization of a patient's intravascular volume status. Therefore, it is crucial that the ED physician knows and uses available means to assess intravascular volume status to adequately guide fluid therapy. This review focuses on techniques for volume status assessment that are available in the ED including basic clinical and laboratory findings, apparatus-based tests such as sonography and chest x-ray, and functional tests to evaluate fluid responsiveness. Furthermore, we provide an outlook on promising innovative, noninvasive technologies that might be used for advanced hemodynamic monitoring in the ED.


Assuntos
Doença Aguda/terapia , Determinação do Volume Sanguíneo/métodos , Volume Sanguíneo/fisiologia , Serviço Hospitalar de Emergência , Hidratação/métodos , Monitorização Hemodinâmica , Humanos , Radiografia Torácica , Ultrassonografia
14.
J Cardiothorac Vasc Anesth ; 31(1): 105-114, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27546828

RESUMO

OBJECTIVE: Blood volume reserve for venous return and the effects of cardiopulmonary bypass (CPB) on microvascular bed partitioning and blood flow were examined in patients with valvular diseases. DESIGN: Prospective, consecutive, case-control study. SETTING: Single university hospital. PARTICIPANTS: The study comprised 20 adult cardiac surgery patients and 20 healthy volunteers. INTERVENTIONS: Cardiovascular and microvascular variables were collected soon after the induction of anesthesia, after commencement of CPB, 20 minutes after separation from CPB, and in the intensive care unit. MEASUREMENTS AND MAIN RESULTS: The unstressed and stressed volumes (Vu, Vs) and pressures therein (Pit, Ps) were measured in the brachioradial muscle with near-infrared spectroscopy, applying incremental venous occlusions. At the first time point, Vs and Pit showed lower and higher values, respectively, than those of control patients, but Vs increased with Vu during the study, whereas Pit remained unchanged. Fluid balance correlated with Pit (r = 0.83, p<0.001) and hemoglobin (r = 0.78, p = 0.004). A nonlinear regression was found between fluid balance and ΔVu (r = 0.90, p<0.001) [y = 1.85+37.43(-0.01×x)]. The Vu/Pit and Vs/Ps ratios were lower than those of the control patients. Blood flow correlated to Vs/Ps (r = 0.75, p<0.001). The time constant was lower than reference (p = 0.005) and increased 10 times after CPB. CONCLUSIONS: Cardiac surgery patients have a limited blood volume reserve for venous return due to a reduced microvascular bed capacitance. This study demonstrated that during CPB a positive fluid balance induced an extravascular pressure increase and further reduced blood volume reserve.


Assuntos
Volume Sanguíneo/fisiologia , Ponte Cardiopulmonar/métodos , Doenças das Valvas Cardíacas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Determinação do Volume Sanguíneo/métodos , Temperatura Corporal/fisiologia , Estudos de Casos e Controles , Complacência (Medida de Distensibilidade)/fisiologia , Feminino , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Músculo Esquelético/irrigação sanguínea , Estudos Prospectivos , Fluxo Sanguíneo Regional/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Resistência Vascular/fisiologia
15.
Eur J Radiol ; 85(9): 1525-31, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27501884

RESUMO

PURPOSE: Aim of the study was to evaluate the impact of parenchymal blood volume (PBV) C-arm CT in transarterial radioembolization (TARE) planning procedure regarding the appropriateness of segmental blood supply from selective catheter positions defined by angiographic images compared to PBV mapsto determine the influence of changed target volumes on dose calculation. MATERIAL AND METHODS: A total of 22 consecutive patients (median age, 62 years) underwent a TARE planning procedure were included in this retrospective study. Selective angiograms and selective PBV C-arm CT (right and left liver lobe) were evaluated in a blinded fashion, regarding segmental hepatic artery variants. Volumetry of target volume and dosimetry of glass and resin microspheres were performed. RESULTS: Classification of segment IV and segment I to the corresponding target vascular bed supply was correct in 91.0% (20/22) and 86.4% (19/22) for angiography and C-arm CT, respectively. Except one case, all other liver segments were classified properly to the left and right hepatic arterial supply. Based on the mismatch of the angiographic and the C-arm CT approach, changes of target volume were evident in 27.3% of patients, resulting in a mean mismatch volume of 90±54ml (range, 51-198ml) and a percentage of dose differences of 14.2±11.8% and 12.6±10.6% for the right and 12.5±8.5% and 11.1±7.8% for the left liver lobe in glass and resin microspheres, respectively. CONCLUSION: The C-arm CT approach is superior to the angiographic determination of vascular supply of specific liver segments for dosimetry before radioembolization. Especially for unexperienced interventional radiologists or for a complex anatomy, C-arm CT improves individualized dosimetry concepts.


Assuntos
Volume Sanguíneo/efeitos da radiação , Embolização Terapêutica/métodos , Artéria Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Volume Sanguíneo/fisiologia , Feminino , Artéria Hepática/fisiopatologia , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Neoplasias Hepáticas/irrigação sanguínea , Masculino , Microesferas , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos
16.
J Magn Reson Imaging ; 44(6): 1673-1682, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27192153

RESUMO

PURPOSE: To test the feasibility and effectiveness of using maximum intensity plots (MIPs) based on 4D flow magnetic resonance imaging (MRI) velocity data to assess systolic peak velocities in a cohort of bicuspid aortic valve (BAV) patients. MATERIALS AND METHODS: 4D flow MRI at 1.5T was performed on 51 BAV patients. MIPs were generated from the 4D flow MRI velocity data and used by two users to determine peak velocities in three regions of interest (ROIs): ascending aorta (AAo), aortic arch, and descending aorta. 4D flow MRI peak velocities in the AAo were compared to peak velocities recorded by 2D phase contrast MRI (2D PCMRI) in a subcohort of 36 patients and by Doppler echocardiography in a subcohort of 34 patients. 4D flow MRI peak velocities recorded by each observer were compared for all ROIs to test for interobserver variability. RESULTS: 4D flow MRI recorded significantly higher velocities compared to 2D PCMRI (2.04 ± 0.71 m/s vs. 1.69 ± 0.79 m/s, 17.2% difference, P < 0.001) and similar velocities compared to Doppler echocardiography. There was excellent agreement between the observers, with a mean difference of 0.005 m/s and an intraclass correlation coefficient of 0.98. CONCLUSION: 4D flow MRI velocity MIPs allow for efficient measurement of peak velocities in BAV patients with higher accuracy than 2D PCMRI and similar accuracy to Doppler echocardiography. J. Magn. Reson. Imaging 2016;44:1673-1682.


Assuntos
Valva Aórtica/anormalidades , Velocidade do Fluxo Sanguíneo/fisiologia , Volume Sanguíneo/fisiologia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adolescente , Algoritmos , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Determinação do Volume Sanguíneo/métodos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
17.
J Thorac Cardiovasc Surg ; 151(6): 1540-6, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26979919

RESUMO

OBJECTIVE: To investigate whether echocardiographic characteristics in the descending aorta of patients with cyanotic congenital heart disease who have received a systemic-to-pulmonary artery (SP) shunt can indicate shunt flow volume and predict postoperative adverse events related to high-flow shunting. METHODS: Among the 73 consecutive patients who received an SP shunt between 2010 and 2014, data for 53 patients who underwent postoperative Doppler echocardiographic assessment of diastolic retrograde flow in the descending aorta (dAo-RF) were reviewed retrospectively. RESULTS: The mean dAo-RF ratio was 0.50 ± 0.15 at intensive care unit admission and reached its peak level (0.56 ± 0.12) at 24 hours after surgery. All of the patients with a maximal dAo-RF ratio of ≥0.80 had experienced acute heart failure or cardiogenic shock due to postoperative high-flow shunting and required emergent surgical interventions to reduce pulmonary blood flow. Pulse oximetry-measured oxygen saturation and serum lactate level were significantly correlated with dAo-RF ratio, but they had some clinical dispersion to match the postoperative adverse events. CONCLUSIONS: The dAo-RF ratio is a simple, repeatable, and noninvasive index for postoperative assessment of SP shunt flow volume. A high dAo-RF ratio is a significant predictor of postoperative adverse events of high-flow shunting.


Assuntos
Aorta Torácica/diagnóstico por imagem , Procedimento de Blalock-Taussig , Volume Sanguíneo/fisiologia , Ecocardiografia Doppler , Insuficiência Cardíaca/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Choque Cardiogênico/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Diástole , Feminino , Seguimentos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia
18.
Clin Biochem ; 48(10-11): 640-5, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25828045

RESUMO

BACKGROUND: Assessment of volume status is essential to best manage hyponatremic patients but is not always accurate in clinical practice. The aim of this study was to evaluate the reliability of C-terminal portion of pro-arginine-vasopressin (CT-pro-AVP), a surrogate biomarker of vasopressin release, in assessing intravascular volume (IVV) depletion in hypoosmolar hyponatremic patients. METHODS: Plasma CT-pro-AVP and urea-to-creatinine ratio (Ur/Cr) were performed in 131 hospitalized patients presenting chronic severe hypoosmolar hyponatremia. At hospital discharge, their IVV was evaluated regardless of CT-pro-AVP concentrations. All patients were then classified as decreased or as normal/expanded IVV group. RESULTS: Plasma CT-pro-AVP levels were higher in patients with decreased IVV (34.6 vs. 11.3 pmol/L, p<0.001) and exhibited a reliable performance for assessment of decreased IVV (ROC AUC at 0.717 [95% CI 0.629-0.805]). The combination of CT-pro-AVP and Ur/Cr resulted in an improved ROC AUC up to 0.787 (95% CI 0.709-0.866). CONCLUSIONS: Our findings support the hypothesis that CT-pro-AVP plasma level may reflect IVV and would be a tool for its assessment. This performance has been magnified by its combination with Ur/Cr. A dual-marker strategy may help clinicians to optimize the management of severe hyponatremia especially in case of confusing clinical presentations.


Assuntos
Arginina Vasopressina/sangue , Volume Sanguíneo/fisiologia , Hiponatremia/sangue , Hiponatremia/diagnóstico , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Hiponatremia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto
19.
Med Eng Phys ; 37(6): 574-83, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25922293

RESUMO

Fluorescence spectroscopy has recently become more common in clinical medicine. However, there are still many unresolved issues related to the methodology and implementation of instruments with this technology. In this study, we aimed to assess individual variability of fluorescence parameters of endogenous markers (NADH, FAD, etc.) measured by fluorescent spectroscopy (FS) in situ and to analyse the factors that lead to a significant scatter of results. Most studied fluorophores have an acceptable scatter of values (mostly up to 30%) for diagnostic purposes. Here we provide evidence that the level of blood volume in tissue impacts FS data with a significant inverse correlation. The distribution function of the fluorescence intensity and the fluorescent contrast coefficient values are a function of the normal distribution for most of the studied fluorophores and the redox ratio. The effects of various physiological (different content of skin melanin) and technical (characteristics of optical filters) factors on the measurement results were additionally studied. The data on the variability of the measurement results in FS should be considered when interpreting the diagnostic parameters, as well as when developing new algorithms for data processing and FS devices.


Assuntos
Pele/metabolismo , Espectrometria de Fluorescência/métodos , Adulto , Povo Asiático , População Negra , Volume Sanguíneo/fisiologia , Simulação por Computador , Feminino , Dedos/irrigação sanguínea , Antebraço/irrigação sanguínea , Humanos , Lasers , Masculino , Melaninas/metabolismo , Modelos Teóricos , Método de Monte Carlo , Pele/irrigação sanguínea , População Branca , Adulto Jovem
20.
Neuroimage ; 112: 382-389, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25818683

RESUMO

Intravascular superparamagnetic iron oxide nanoparticles (SPION)-enhanced MR transverse relaxation rates (∆R2(⁎) and ∆R2) are widely used to investigate in vivo vascular parameters, such as the cerebral blood volume (CBV), microvascular volume (MVV), and mean vessel size index (mVSI, ∆R2(⁎)/∆R2). Although highly efficient, regional comparison of vascular parameters acquired using gradient-echo based ∆R2(⁎) is hampered by its high sensitivity to magnetic field perturbations arising from air-tissue interfaces and large vessels. To minimize such demerits, we took advantage of the dual contrast property of SPION and both theoretically and experimentally verified the direct benefit of replacing gradient-echo based ∆R2(⁎) measurement with ultra-short echo time (UTE)-based ∆R1 contrast to generate the robust CBV and mVSI maps. The UTE acquisition minimized the local measurement errors from susceptibility perturbations and enabled dose-independent CBV measurement using the vessel/tissue ∆R1 ratio, while independent spin-echo acquisition enabled simultaneous ∆R2 measurement and mVSI calculation of the cortex, cerebellum, and olfactory bulb, which are animal brain regions typified by significant susceptibility-associated measurement errors.


Assuntos
Vasos Sanguíneos/anatomia & histologia , Volume Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Imagem Ecoplanar/métodos , Algoritmos , Animais , Simulação por Computador , Compostos Férricos , Processamento de Imagem Assistida por Computador , Masculino , Nanopartículas Metálicas , Camundongos , Camundongos Nus , Microcirculação/fisiologia , Método de Monte Carlo , Reprodutibilidade dos Testes