1.
PLoS One ; 19(5): e0303443, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753734

RESUMO

INTRODUCTION: During the COVID-19 pandemic, ventilator shortages necessitated the development of new, low-cost ventilator designs. The fundamental requirements of a ventilator include precise gas delivery, rapid adjustments, durability, and user-friendliness, often achieved through solenoid valves. However, few solenoid-valve assisted low-cost ventilator (LCV) designs have been published, and gas exchange evaluation during LCV testing is lacking. This study describes the development and performance evaluation of a solenoid-valve assisted low-cost ventilator (SV-LCV) in vitro and in vivo, focusing on gas exchange and respiratory mechanics. METHODS: The SV-LCV, a fully open ventilator device, was developed with comprehensive hardware and design documentation, utilizing solenoid valves for gas delivery regulation. Lung simulator testing calibrated tidal volumes at specified inspiratory and expiratory times, followed by in vivo testing in a porcine model to compare SV-LCV performance with a conventional ventilator. RESULTS: The SV-LCV closely matched the control ventilator's respiratory profile and gas exchange across all test cycles. Lung simulator testing revealed direct effects of compliance and resistance changes on peak pressures and tidal volumes, with no significant changes in respiratory rate. In vivo testing demonstrated comparable gas exchange parameters between SV-LCV and conventional ventilator across all cycles. Specifically, in cycle 1, the SV-LCV showed arterial blood gas (ABG) results of pH 7.54, PCO2 34.5 mmHg, and PO2 91.7 mmHg, compared to the control ventilator's ABG of pH 7.53, PCO2 37.1 mmHg, and PO2 134 mmHg. Cycle 2 exhibited ABG results of pH 7.53, PCO2 33.6 mmHg, and PO2 84.3 mmHg for SV-LCV, and pH 7.5, PCO2 34.2 mmHg, and PO2 93.5 mmHg for the control ventilator. Similarly, cycle 3 showed ABG results of pH 7.53, PCO2 32.1 mmHg, and PO2 127 mmHg for SV-LCV, and pH 7.5, PCO2 35.5 mmHg, and PO2 91.3 mmHg for the control ventilator. CONCLUSION: The SV-LCV provides similar gas exchange and respiratory mechanic profiles compared to a conventional ventilator. With a streamlined design and performance akin to commercially available ventilators, the SV-LCV presents a viable, readily available, and reliable short-term solution for overcoming ventilator supply shortages during crises.


Assuntos
COVID-19 , Troca Gasosa Pulmonar , Mecânica Respiratória , Ventiladores Mecânicos , Animais , Suínos , Desenho de Equipamento , Respiração Artificial/instrumentação , Respiração Artificial/métodos , SARS-CoV-2 , Volume de Ventilação Pulmonar
2.
Respir Care ; 69(8): 924-930, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-38688544

RESUMO

BACKGROUND: The bag-valve-mask (BVM) or manual resuscitator bag is used as a first-line technique to ventilate patients with respiratory failure. Volume-restricted manual resuscitator bags (eg, pediatric bags) have been suggested to minimize overventilation and associated complications. There are studies that both support and caution against the use of a pediatric resuscitator bag to ventilate an adult patient. In this study, we evaluated the ability of pre-hospital clinicians to adequately ventilate an adult manikin with both an adult- and pediatric-size manual resuscitator bag without the assistance of an advanced airway or airway adjunct device. METHODS: This study was conducted at an international conference in 2022. Conference attendees with pre-hospital health care experience were recruited to ventilate an adult manikin using a BVM for 1 min with both an adult and pediatric resuscitator bag, without the use of adjunct airway devices, while 6 ventilatory variables were collected or calculated: tidal volume (VT), breathing frequency, adequate breaths (VT > 150 mL), proportion of adequate breaths, peak inspiratory pressure (PIP), and estimated alveolar ventilation (EAV). RESULTS: A total of 208 participants completed the study. Ventilation with the adult-sized BVM delivered an average VT of 290.4 mL compared to 197.1 mL (P < .001) when using the pediatric BVM. PIP with the adult BVM was higher than with the pediatric BVM (10.6 cm H2O vs 8.6 cm H2O, P < .001). The median EAV with the adult bag (1,138.1 [interquartile range [IQR] 194.0-2,869.9] mL/min) was markedly greater than with the pediatric BVM (67.7 [IQR 0-467.3] mL/min, P < .001). CONCLUSIONS: Both pediatric- and adult-sized BVM provided lower ventilation volumes than those recommended by professional guidelines for an adult. Ventilation with the pediatric BVM was significantly worse than with the adult bag when ventilating a simulated adult subject.


Assuntos
Manequins , Respiração Artificial , Volume de Ventilação Pulmonar , Humanos , Adulto , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Masculino , Feminino , Desenho de Equipamento , Taxa Respiratória
3.
Respir Physiol Neurobiol ; 320: 104199, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38000708

RESUMO

PURPOSE: To investigate the correlation between volume of carbon dioxide elimination (V̇CO2) and end-tidal carbon dioxide (PETCO2) with cardiac output (CO) in a swine pediatric acute respiratory distress syndrome (ARDS) model. METHODS: Respiratory and hemodynamic variables were collected from twenty-six mechanically ventilated juvenile pigs under general anesthesia before and after inducing ARDS, using oleic acid infusion. RESULTS: Prior to ARDS induction, mean (SD) CO, V̇CO2, PETCO2, and dead space to tidal volume ratio (Vd/Vt) were 4.16 (1.10) L/min, 103.69 (18.06) ml/min, 40.72 (3.88) mmHg and 0.25 (0.09) respectively. Partial correlation coefficients between average CO, V̇CO2, and PETCO2 were 0.44 (95% confidence interval: 0.18-0.69) and 0.50 (0.18-0.74), respectively. After ARDS induction, mean CO, V̇CO2, PETCO2, and Vd/Vt were 3.33 (0.97) L/min, 113.71 (22.97) ml/min, 50.17 (9.73) mmHg and 0.40 (0.08). Partial correlations between CO and V̇CO2 was 0.01 (-0.31 to 0.37) and between CO and PETCO2 was 0.35 (-0.002 to 0.65). CONCLUSION: ARDS may limit the utility of volumetric capnography to monitor CO.


Assuntos
Dióxido de Carbono , Síndrome do Desconforto Respiratório , Humanos , Criança , Animais , Suínos , Volume de Ventilação Pulmonar , Débito Cardíaco , Capnografia , Respiração Artificial
4.
Paediatr Anaesth ; 34(3): 251-258, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38055609

RESUMO

BACKGROUND: Capnodynamic lung function monitoring generates variables that may be useful for pediatric perioperative ventilation. AIMS: Establish normal values for end-expiratory lung volume CO2 in healthy children undergoing anesthesia and to compare these values to previously published values obtained with alternative end-expiratory lung volume methods. The secondary aim was to investigate the ability of end-expiratory lung volume CO2 to react to positive end-expiratory pressure-induced changes in end-expiratory lung volume. In addition, normal values for associated volumetric capnography lung function variables were examined. METHODS: Fifteen pediatric patients with healthy lungs (median age 8 months, range 1-36 months) undergoing general anesthesia were examined before start of surgery. Tested variables were recorded at baseline positive end-expiratory pressure 3 cmH2 O, 1 and 3 min after positive end-expiratory pressure 10 cmH2 O and 3 min after returning to baseline positive end-expiratory pressure 3 cmH2 O. RESULTS: Baseline end-expiratory lung volume CO2 was 32 mL kg-1 (95% CI 29-34 mL kg-1 ) which increased to 39 mL kg-1 (95% CI 35-43 mL kg-1 , p < .0001) and 37 mL kg-1 (95% CI 34-41 mL kg-1 , p = .0003) 1 and 3 min after positive end-expiratory pressure 10 cmH2 O, respectively. End-expiratory lung volume CO2 returned to baseline, 33 mL kg-1 (95% CI 29-37 mL kg-1 , p = .72) 3 min after re-establishing positive end-expiratory pressure 3 cmH2 O. Airway dead space increased from 1.1 mL kg-1 (95% CI 0.9-1.4 mL kg-1 ) to 1.4 (95% CI 1.1-1.8 mL kg-1 , p = .003) and 1.5 (95% CI 1.1-1.8 mL kg-1 , p < .0001) 1 and 3 min after positive end-expiratory pressure 10 cmH2 O, respectively, and 1.2 mL kg-1 (95% CI 0.9-1.4 mL kg-1 , p = .08) after 3 min of positive end-expiratory pressure 3 cmH2 O. Additional volumetric capnography and lung function variables showed no major changes in response to positive end-expiratory pressure variations. CONCLUSIONS: Capnodynamic noninvasive and continuous end-expiratory lung volume CO2 values assessed during anesthesia in children were in close agreement with previously reported end-expiratory lung volume values generated by alternative methods. Furthermore, positive end-expiratory pressure changes resulted in physiologically expected end-expiratory lung volume CO2 responses in a timely manner, suggesting that it can be used to trend end-expiratory lung volume changes during anesthesia.


Assuntos
Dióxido de Carbono , Respiração , Humanos , Criança , Lactente , Pré-Escolar , Medidas de Volume Pulmonar , Respiração com Pressão Positiva , Pulmão , Anestesia Geral , Volume de Ventilação Pulmonar
6.
BMC Anesthesiol ; 23(1): 239, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37454135

RESUMO

OBJECTIVES: To develop and assess a system for shared ventilation using clinically available components to individualize tidal volumes. DESIGN: Evaluation and in vitro validation study SETTING: Ventilator shortage during the SARS-CoV-2 pandemic. PARTICIPANTS: The team consisted of physicians, bioengineers, computer programmers, and medical technology professionals. METHODS: Using clinically available components, a system of ventilation consisting of two ventilatory limbs was assembled and connected to a ventilator. Monitors for each limb were developed using open-source software. Firstly, the effect of altering ventilator settings on tidal volumes delivered to each limb was determined. Secondly, the impact of altering the compliance and resistance of one limb on the tidal volumes delivered to both limbs was analysed. Experiments were repeated three times to determine system variability. RESULTS: The system permitted accurate and reproducible titration of tidal volumes to each limb over a range of ventilator settings and simulated lung conditions. Alteration of ventilator inspiratory pressures, of respiratory rates, and I:E ratio resulted in very similar tidal volumes delivered to each limb. Alteration of compliance and resistance in one limb resulted in reproducible alterations in tidal volume to that test lung, with little change to tidal volumes in the other lung. All tidal volumes delivered were reproducible. CONCLUSIONS: We demonstrate the reliability of a shared ventilation system assembled using commonly available clinical components that allows titration of individual tidal volumes. This system may be useful as a strategy of last resort for Covid-19, or other mass casualty situations, where the need for ventilators exceeds supply.


Assuntos
COVID-19 , Humanos , Volume de Ventilação Pulmonar , COVID-19/terapia , Reprodutibilidade dos Testes , SARS-CoV-2 , Ventiladores Mecânicos , Respiração Artificial/métodos
7.
West J Emerg Med ; 24(3): 502-510, 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37278778

RESUMO

INTRODUCTION: Low tidal-volume ventilation (LTVV), defined as a maximum tidal volume of 8 milliliters per kilogram (mL/kg) of ideal body weight, is a key component of lung protective ventilation. Although emergency department (ED) initiation of LTVV has been associated with improved outcomes, disparities in LTVV application exist. In this study our aim was to evaluate whether rates of LTVV are associated with demographic and physical characteristics in the ED. METHODS: We conducted a retrospective observational cohort study using a dataset of patients who underwent mechanical ventilation at three EDs in two health systems from January 2016-June 2019. Demographic, mechanical ventilation, and outcome data including mortality and hospital-free days were abstracted by automatic query. A LTVV approach was defined as a tidal volume ≤8 mL/kg ideal body weight. We performed descriptive statistics and univariate analysis as indicated, and created a multivariate logistic regression model. RESULTS: Of 1,029 patients included in the study, 79.5% received LTVV. Tidal volumes of 400-500 mL were used in 81.9% of patients. Approximately 18% of patients had tidal volumes changed in the ED. Female gender (adjusted odds ratio [aOR] 4.17, P< 0.001), obesity (aOR 2.27, P< 0.001), and first-quartile height (aOR 12.2, P < 0.001) were associated with receiving non-LTVV in multivariate regression analysis. Hispanic ethnicity and female gender were associated with first quartile height (68.5%, 43.7%, P < 0.001 for all). Hispanic ethnicity was associated with receiving non-LTVV in univariate analysis (40.8% vs 23.0%, P < 0.001). This relationship did not persist in sensitivity analysis controlling for height, weight, gender, and body mass index. Patients who received LTVV in the ED had 2.1 more hospital-free days compared to those who did not (P = 0.040). No difference in mortality was observed. CONCLUSION: Emergency physicians use a narrow range of initial tidal volumes that may not meet lung-protective ventilation goals, with few corrections. Female gender, obesity, and first-quartile height are independently associated with receiving non-LTVV in the ED. Using LTVV in the ED was associated with 2.1 fewer hospital-free days. If confirmed in future studies, these findings have important implications for achieving quality improvement and health equality.


Assuntos
Serviço Hospitalar de Emergência , Respiração Artificial , Humanos , Feminino , Volume de Ventilação Pulmonar , Estudos Retrospectivos , Pulmão , Obesidade/epidemiologia , Obesidade/terapia
8.
Crit Care ; 27(1): 157, 2023 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-37081517

RESUMO

At the bedside, assessing the risk of ventilator-induced lung injury (VILI) requires parameters readily measured by the clinician. For this purpose, driving pressure (DP) and end-inspiratory static 'plateau' pressure ([Formula: see text]) of the tidal cycle are unquestionably useful but lack key information relating to associated volume changes and cumulative strain. 'Mechanical power', a clinical term which incorporates all dissipated ('non-elastic') and conserved ('elastic') energy components of inflation, has drawn considerable interest as a comprehensive 'umbrella' variable that accounts for the influence of ventilating frequency per minute as well as the energy cost per tidal cycle. Yet, like the raw values of DP and [Formula: see text], the absolute levels of energy and power by themselves may not carry sufficiently precise information to guide safe ventilatory practice. In previous work we introduced the concept of 'damaging energy per cycle'. Here we describe how-if only in concept-the bedside clinician might gauge the theoretical hazard of delivered energy using easily observed static circuit pressures ([Formula: see text] and positive end expiratory pressure) and an estimate of the maximally tolerated (threshold) non-dissipated ('elastic') airway pressure that reflects the pressure component applied to the alveolar tissues. Because its core inputs are already in use and familiar in daily practice, the simplified mathematical model we propose here for damaging energy and power may promote deeper comprehension of the key factors in play to improve lung protective ventilation.


Assuntos
Síndrome do Desconforto Respiratório , Lesão Pulmonar Induzida por Ventilação Mecânica , Humanos , Volume de Ventilação Pulmonar , Síndrome do Desconforto Respiratório/complicações , Respiração Artificial/efeitos adversos , Lesão Pulmonar Induzida por Ventilação Mecânica/etiologia , Lesão Pulmonar Induzida por Ventilação Mecânica/prevenção & controle , Modelos Teóricos
9.
J Bone Joint Surg Am ; 105(1): 53-62, 2023 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-36598475

RESUMO

BACKGROUND: Quantitative regional assessment of thoracic function would enable clinicians to better understand the regional effects of therapy and the degree of deviation from normality in patients with thoracic insufficiency syndrome (TIS). The purpose of this study was to determine the regional functional effects of surgical treatment in TIS via quantitative dynamic magnetic resonance imaging (MRI) in comparison with healthy children. METHODS: Volumetric parameters were derived via 129 dynamic MRI scans from 51 normal children (November 2017 to March 2019) and 39 patients with TIS (preoperatively and postoperatively, July 2009 to May 2018) for the left and right lungs, the left and right hemi-diaphragms, and the left and right hemi-chest walls during tidal breathing. Paired t testing was performed to compare the parameters from patients with TIS preoperatively and postoperatively. Mahalanobis distances between parameters of patients with TIS and age-matched normal children were assessed to evaluate the closeness of patient lung function to normality. Linear regression functions were utilized to estimate volume deviations of patients with TIS from normality, taking into account the growth of the subjects. RESULTS: The mean Mahalanobis distances for the right hemi-diaphragm tidal volume (RDtv) were -1.32 ± 1.04 preoperatively and -0.05 ± 1.11 postoperatively (p = 0.001). Similarly, the mean Mahalanobis distances for the right lung tidal volume (RLtv) were -1.12 ± 1.04 preoperatively and -0.10 ± 1.26 postoperatively (p = 0.01). The mean Mahalanobis distances for the ratio of bilateral hemi-diaphragm tidal volume to bilateral lung tidal volume (BDtv/BLtv) were -1.68 ± 1.21 preoperatively and -0.04 ± 1.10 postoperatively (p = 0.003). Mahalanobis distances decreased after treatment, suggesting reduced deviations from normality. Regression results showed that all volumes and tidal volumes significantly increased after treatment (p < 0.001), and the tidal volume increases were significantly greater than those expected from normal growth for RDtv, RLtv, BDtv, and BLtv (p < 0.05). CONCLUSIONS: Postoperative tidal volumes of bilateral lungs and bilateral hemi-diaphragms of patients with TIS came closer to those of normal children, indicating positive treatment effects from the surgical procedure. Quantitative dynamic MRI facilitates the assessment of regional effects of a surgical procedure to treat TIS. LEVEL OF EVIDENCE: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Pulmão , Respiração , Criança , Humanos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Tórax/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Volume de Ventilação Pulmonar
10.
Comput Methods Programs Biomed ; 226: 107176, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36228494

RESUMO

BACKGROUND: Optimal setting of mechanical ventilators is critical for improving outcomes. Accurate, predictive lung mechanics models are effective in optimizing MV settings, but only at a global level as they cannot estimate regional lung volume ventilation to assess the potential of local distension or under-ventilation. This study presents a low-cost structured light system for non-contact high resolution chest motion measurement to estimate regional lung volume changes. METHODS: The system consists of a structured light projector and two cameras. A new pattern is designed to extract motion from sub-regions of the chest surface, and an efficient feature is proposed to provide a fast and accurate correspondence matching between two views. Reconstruction of 3D surface points is based on the matched points and stereo method. Asymmetric distribution of tidal volume into left and right lungs is estimated based on reconstructed regional chest expansion. A proof-of-concept experiment using a dummy model and two test lungs connected to a ventilator to provide differential chest expansion is conducted under tidal volumes of 400 ml, 500 ml and 600 ml, with results compared to the widely-used SURF and ORB methods. RESULTS: Compared to the SURF and ORB methods, the proposed method is more computationally efficient with ∼40% less computational time cost, and higher accuracy for dense point correspondence. Finally, the proposed method estimated the region lung volumes with the maximum error of 8 ml under 600 ml tidal volume, indicating a good accuracy. CONCLUSIONS: Surface reconstruction results in a proof-of-concept experiment with differential chest expansion show good performance for the proposed pattern and method in extracting the key information for regional chest expansion. The proposed method is generalizable, with potential for use in other applications.


Assuntos
Respiração Artificial , Ventiladores Mecânicos , Respiração Artificial/métodos , Volume de Ventilação Pulmonar , Pulmão/diagnóstico por imagem , Respiração
11.
J Healthc Eng ; 2022: 6436818, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35368917

RESUMO

The outbreak of novel COVID-19 has severely and unprecedentedly affected millions of people across the globe. The painful respiratory distress caused during this disease calls for external assistance to the victims in the form of ventilation. The most common types of artificial ventilating units available at the healthcare facilities and hospitals are exorbitantly expensive to manufacture, and their number is fairly inadequate even in the so-called developed countries to cater to the burning needs of an ever-increasing number of ailing human subjects. According to available reports, without the provision of ventilation, the novel COVID-19 patients are succumbing to their ailments in a huge number of cases. This colossal problem of the availability of ventilator units can be addressed to a great extent by readily producible and cost-effective ventilating units that can be used on those suffering patients during an acute emergency and in the absence of conventional expensive ventilators at hospitals and medical care units. This paper has made an attempt to design and simulate a simple, yet effective, mechanized ventilator unit, which can be conveniently assembled without a profuse skillset and operated to resuscitate an ailing human patient. The stepper motor-controlled kinematic linkage is designed to deliver the patient with a necessitated discharge of air at optimum oxygen saturation through the AMBU bag connected in a ventilation circuit. With the associated code on MATLAB, the motor control parameters such as angular displacement and speed are deduced according to the input patient conditions (age group, tidal volume, breathing rate, etc.) and thereafter fed to the controller that drives the stepper motor. With a proposed feedback loop, the real-time static and dynamic compliance, airway resistance values can be approximately determined from the pressure variation cycle and fed to the controller unit to adjust the tidal volume as and when necessary. The simplistic yet robust design not only renders easy manufacturability by conventional and rapid prototyping techniques like 3D printing at different scales but also makes the product easily portable with minimal handling difficulty. Keeping the motto of Health for All as envisioned by the WHO, this low-cost indigenously engineered ventilator will definitely help the poor and afflicted towards their right to health and will help the medical professionals buy some time to manage the patient with acute respiratory distress syndrome (ARDS) towards recovery. Moreover, this instrument mostly includes readily available functional units having standard specifications and can be considered as standard bought-out items.


Assuntos
COVID-19 , Humanos , Pandemias , Respiração Artificial/métodos , Volume de Ventilação Pulmonar , Ventiladores Mecânicos
13.
PLoS One ; 17(3): e0265315, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35290404

RESUMO

BACKGROUND: Cardiopulmonary exercise testing has demonstrated clinical utility in myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). However, to what extent exercise responses are independent of, or confounded by, aerobic fitness remains unclear. PURPOSE: To characterize and compare exercise responses in ME/CFS and controls with and without matching for aerobic fitness. METHODS: As part of the Multi-site Clinical Assessment of ME/CFS (MCAM) study, 403 participants (n = 214 ME/CFS; n = 189 controls), across six ME/CFS clinics, completed ramped cycle ergometry to volitional exhaustion. Metabolic, heart rate (HR), and ratings of perceived exertion (RPE) were measured. Ventilatory equivalent ([Formula: see text], [Formula: see text]), metrics of ventilatory efficiency, and chronotropic incompetence (CI) were calculated. Exercise variables were compared using Hedges' g effect size with 95% confidence intervals. Differences in cardiopulmonary and perceptual features during exercise were analyzed using linear mixed effects models with repeated measures for relative exercise intensity (20-100% peak [Formula: see text]). Subgroup analyses were conducted for 198 participants (99 ME/CFS; 99 controls) matched for age (±5 years) and peak [Formula: see text] (~1 ml/kg/min-1). RESULTS: Ninety percent of tests (n = 194 ME/CFS, n = 169 controls) met standard criteria for peak effort. ME/CFS responses during exercise (20-100% peak [Formula: see text]) were significantly lower for ventilation, breathing frequency, HR, measures of efficiency, and CI and significantly higher for [Formula: see text], [Formula: see text] and RPE (p<0.05adjusted). For the fitness-matched subgroup, differences remained for breathing frequency, [Formula: see text], [Formula: see text], and RPE (p<0.05adjusted), and higher tidal volumes were identified for ME/CFS (p<0.05adjusted). Exercise responses at the gas exchange threshold, peak, and for measures of ventilatory efficiency (e.g., [Formula: see text]) were generally reflective of those seen throughout exercise (i.e., 20-100%). CONCLUSION: Compared to fitness-matched controls, cardiopulmonary responses to exercise in ME/CFS are characterized by inefficient exercise ventilation and augmented perception of effort. These data highlight the importance of distinguishing confounding fitness effects to identify responses that may be more specifically associated with ME/CFS.


Assuntos
Exercício Físico , Síndrome de Fadiga Crônica , Teste de Esforço , Frequência Cardíaca , Humanos , Consumo de Oxigênio/fisiologia , Esforço Físico , Aptidão Física , Volume de Ventilação Pulmonar
14.
Pulmonology ; 28(2): 90-98, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34906445

RESUMO

INTRODUCTION AND OBJECTIVES: Information about epidemiology, ventilation management and outcome in postoperative intensive care unit (ICU) patients remains scarce. The objective was to test whether postoperative ventilation differs from that in the operation room. MATERIAL AND METHODS: This was a substudy of the worldwide observational LAS VEGAS study, including patients undergoing non-thoracic surgeries. Of 146 study sites participating in the LAS VEGAS study, 117 (80%) sites reported on the postoperative ICU course, including ventilation and complications. The coprimary outcomes were two key elements of ventilator management, i.e., tidal volume (VT) and positive end-expiratory pressure (PEEP). Secondary outcomes included the proportion of patients receiving low VT ventilation (LTVV, defined as ventilation with a median VT < 8.0 ml/kg PBW), and the proportion of patients developing postoperative pulmonary complications (PPC), including ARDS, pneumothorax, pneumonia and need for escalation of ventilatory support, ICU and hospital length of stay, and mortality at day 28. RESULTS: Of 653 patients who were admitted to the ICU after surgery, 274 (42%) patients received invasive postoperative ventilation. Median postoperative VT was 8.4 [7.3-9.8] ml/kg predicted body weight (PBW), PEEP was 5 [5-5] cm H2O, statistically significant but not meaningfully different from median intraoperative VT (8.1 [7.3-8.9] ml/kg PBW; P < 0.001) and PEEP (4 [2-5] cm H2O; P < 0.001). The proportion of patients receiving LTVV after surgery was 41%. The PPC rate was 10%. Length of stay in ICU and hospital was independent of development of a PPC, but hospital mortality was higher in patients who developed a PPC (24 versus 4%; P < 0.001). CONCLUSIONS: In this observational study of patients undergoing non-thoracic surgeries, postoperative ventilation was not meaningfully different from that in the operating room. Like in the operating room, there is room for improved use of LTVV. Development of PPC is associated with mortality.


Assuntos
Respiração com Pressão Positiva , Respiração Artificial , Cuidados Críticos , Humanos , Respiração Artificial/efeitos adversos , Volume de Ventilação Pulmonar , Ventiladores Mecânicos
15.
IEEE Trans Biomed Eng ; 69(6): 1964-1974, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34855581

RESUMO

OBJECTIVE: The objectives of this study were to develop a multi-channel trans-impedance leadforming method for beat-to-beat stroke volume (SV) and breath-by-breath tidal volume (TV) measurements and assess its feasibility on an existing in vivo animal dataset. METHODS: A deterministic leadforming algorithm was developed to extract a cardiac volume signal (CVS) and a respiratory volume signal (RVS) from 208-channel trans-impedance data acquired every 20 ms by an electrical impedance tomography (EIT) device. SVEIT and TVEIT values were computed as a valley-to-peak value in the CVS and RVS, respectively. The method was applied to the existing dataset from five mechanically-ventilated pigs undergoing ten mini-fluid challenges. An invasive hemodynamic monitor was used in the arterial pressure-based cardiac output (APCO) mode to simultaneously measure SVAPCO values while a mechanical ventilator provided TVVent values. RESULTS: The leadforming method could reliably extract the CVS and RVS from the 208-channel trans-impedance data measured with the EIT device, from which SVEIT and TVEIT were computed. The SVEIT and TVEIT values were comparable to those from the invasive hemodynamic monitor and mechanical ventilator. Using the data from 5 pigs and a simple calibration method to remove bias, the error in SVEIT and TVEIT was 9.5% and 5.4%, respectively. CONCLUSION: We developed a new leadforming method for the EIT device to robustly extract both SV and TV values in a deterministic fashion. Future animal and clinical studies are needed to validate this leadforming method in various subject populations. SIGNIFICANCE: The leadforming method could be an integral component for a new cardiopulmonary monitor in the future to simultaneously measure SV and TV noninvasively, which would be beneficial to patients.


Assuntos
Algoritmos , Tomografia , Animais , Impedância Elétrica , Estudos de Viabilidade , Humanos , Suínos , Volume de Ventilação Pulmonar , Tomografia/métodos
16.
J Clin Monit Comput ; 36(4): 1173-1180, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34480238

RESUMO

While plateau airway pressure alone is an unreliable estimate of lung overdistension inspiratory transpulmonary pressure (PL) is an important parameter to reflect it in patients with ARDS and there is no concensus about which computation method should be used to calculate it. Recent studies suggest that different formulas may lead to different tidal volume and PEEP settings. The aim of this study is to compare 3 different inspiratory PL measurement method; direct measurement (PLD), elastance derived (PLE) and release derived (PLR) methods in patients with multiple mechanical abnormalities. 34 patients were included in this prospective observational study. Measurements were obtained during volume controlled mechanical ventilation in sedated and paralyzed patients. During the study day airway and eosephageal pressures, flow, tidal volume were measured and elastance, inspiratory PLE, PLD and PLR were calculated. Mean age of the patients was 67 ± 15 years and APACHE II score was 27 ± 7. Most frequent diagnosis of the patients were pneumonia (71%), COPD exacerbation(56%), pleural effusion (55%) and heart failure(50%). Mean plateau pressure of the patients was 22 ± 5 cmH2O and mean respiratory system elastance was 36.7 ± 13 cmH2O/L. EL/ERS% was 0.75 ± 0.35%. Mean expiratory transpulmonary pressure was 0.54 ± 7.7 cmH2O (min: - 21, max: 12). Mean PLE (18 ± 9 H2O) was significantly higher than PLD (13 ± 9 cmH2O) and PLR methods (11 ± 9 cmH2O). There was a good aggreement and there was no bias between the measurements in Bland-Altman analysis. The estimated bias was similar between the PLD and PLE (- 3.12 ± 11 cmH2O) and PLE and PLR (3.9 ± 10.9 cmH2O) measurements. Our results suggest that standardization of calculation method of inspiratory PL is necessary before using it routinely to estimate alveolar overdistension.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Idoso , Idoso de 80 Anos ou mais , Humanos , Pulmão , Pessoa de Meia-Idade , Respiração com Pressão Positiva/métodos , Pressão , Síndrome do Desconforto Respiratório/diagnóstico , Mecânica Respiratória , Volume de Ventilação Pulmonar
17.
Lancet Glob Health ; 10(2): e227-e235, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34914899

RESUMO

BACKGROUND: Geoeconomic variations in epidemiology, the practice of ventilation, and outcome in invasively ventilated intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) remain unexplored. In this analysis we aim to address these gaps using individual patient data of four large observational studies. METHODS: In this pooled analysis we harmonised individual patient data from the ERICC, LUNG SAFE, PRoVENT, and PRoVENT-iMiC prospective observational studies, which were conducted from June, 2011, to December, 2018, in 534 ICUs in 54 countries. We used the 2016 World Bank classification to define two geoeconomic regions: middle-income countries (MICs) and high-income countries (HICs). ARDS was defined according to the Berlin criteria. Descriptive statistics were used to compare patients in MICs versus HICs. The primary outcome was the use of low tidal volume ventilation (LTVV) for the first 3 days of mechanical ventilation. Secondary outcomes were key ventilation parameters (tidal volume size, positive end-expiratory pressure, fraction of inspired oxygen, peak pressure, plateau pressure, driving pressure, and respiratory rate), patient characteristics, the risk for and actual development of acute respiratory distress syndrome after the first day of ventilation, duration of ventilation, ICU length of stay, and ICU mortality. FINDINGS: Of the 7608 patients included in the original studies, this analysis included 3852 patients without ARDS, of whom 2345 were from MICs and 1507 were from HICs. Patients in MICs were younger, shorter and with a slightly lower body-mass index, more often had diabetes and active cancer, but less often chronic obstructive pulmonary disease and heart failure than patients from HICs. Sequential organ failure assessment scores were similar in MICs and HICs. Use of LTVV in MICs and HICs was comparable (42·4% vs 44·2%; absolute difference -1·69 [-9·58 to 6·11] p=0·67; data available in 3174 [82%] of 3852 patients). The median applied positive end expiratory pressure was lower in MICs than in HICs (5 [IQR 5-8] vs 6 [5-8] cm H2O; p=0·0011). ICU mortality was higher in MICs than in HICs (30·5% vs 19·9%; p=0·0004; adjusted effect 16·41% [95% CI 9·52-23·52]; p<0·0001) and was inversely associated with gross domestic product (adjusted odds ratio for a US$10 000 increase per capita 0·80 [95% CI 0·75-0·86]; p<0·0001). INTERPRETATION: Despite similar disease severity and ventilation management, ICU mortality in patients without ARDS is higher in MICs than in HICs, with a strong association with country-level economic status. FUNDING: No funding.


Assuntos
Países Desenvolvidos/estatística & dados numéricos , Países em Desenvolvimento/estatística & dados numéricos , Unidades de Terapia Intensiva/estatística & dados numéricos , Respiração Artificial/métodos , Respiração Artificial/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar/tendências , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores Sociodemográficos , Volume de Ventilação Pulmonar
18.
Respir Physiol Neurobiol ; 296: 103801, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34626830

RESUMO

Chronic obstructive pulmonary disease (COPD) patients often experience tidal expiratory flow-limitation (tEFL), a condition causing respiratory and cardiovascular detrimental effects. As the appearance of tEFL should increase expiratory (Rexp) relative to inspiratory (Rins) resistance, we hypothesized that Rexp/Rins can be used to detect tEFL. Rexp/Rins was measured with a commercial plethysmograph in 109 healthy subjects and, before and after bronchodilation (BD), in 64 COPD patients, 36 with and 28 without tEFL according to the NEP technique. Before BD, the median (interquartile range) of Rexp/Rins was significantly greater (P < 0.001) in COPD patients with tEFL (2.47(3.06;7.07)) than in COPD patients without tEFL (1.63(1.44;1.82)) and in healthy subjects (1.52(1.35;1.62)). In COPD patients Rexp/Rins above 1.98 predicted the presence of tEFL with 96 % specificity and 92 % sensitivity, Rexp2/Rins performing even better. After BD the predictive ability of Rexp/Rins slightly declined, but remained elevated. The non-invasive measurement of Rexp/Rins is an easy, inexpensive, routinely usable method to detect tEFL in spontaneously breathing COPD subjects.


Assuntos
Expiração/fisiologia , Inalação/fisiologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Volume de Ventilação Pulmonar/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pletismografia
19.
J Intensive Care Med ; 37(6): 793-802, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34165010

RESUMO

BACKGROUND: Acute respiratory distress syndrome (ARDS) is a highly morbid condition that has limited therapeutic options. Optimal vitamin D status has been linked to immunological effects that may benefit critically ill patients. Therefore, we investigated whether admission 25-hydroxyvitamin D levels (25OHD) are associated with clinical outcomes in ARDS patients. METHODS: We performed a secondary analysis of data from a randomized, controlled trial comparing oxygenation strategies in 549 patients with ARDS (NCT00000579). Baseline 25OHD was measured in stored plasma samples. We investigated the relationship between vitamin D status and ventilator-free days (VFD) as well as 90-day survival, using linear regression and Cox proportional hazard models, respectively. Analyses were adjusted for age, race, and Acute Physiology and Chronic Health Evaluation III score. RESULTS: Baseline 25OHD was measured in 476 patients. 90% of these individuals had 25OHD <20 ng/ml and 40% had 25OHD <10 ng/ml. Patients with 25OHD <20 ng/ml were likely to be ventilated for 3 days longer than patients with levels ≥20 ng/ml (ß 3.41; 95%CI 0.42-6.39: P = 0.02). Patients with 25OHD <10 ng/ml were likely to be ventilated for 9 days longer (ß 9.27; 95%CI 7.24-11.02: P < 0.001) and to have a 34% higher risk of 90-day mortality (HR 1.34; 95% CI 1.06-1.71: P = 0.02) compared to patients with levels >10 ng/ml. CONCLUSIONS: In patients with ARDS, vitamin D status is associated with duration of mechanical ventilation and 90-day mortality. Randomized, controlled trials are warranted to determine whether vitamin D supplementation improves clinical outcomes in ARDS patients.


Assuntos
Lesão Pulmonar , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar , Vitamina D
20.
Sensors (Basel) ; 21(4)2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33671202

RESUMO

Respiratory activity is an important vital sign of life that can indicate health status. Diseases such as bronchitis, emphysema, pneumonia and coronavirus cause respiratory disorders that affect the respiratory systems. Typically, the diagnosis of these diseases is facilitated by pulmonary auscultation using a stethoscope. We present a new attempt to develop a lightweight, comprehensive wearable sensor system to monitor respiration using a multi-sensor approach. We employed new wearable sensor technology using a novel integration of acoustics and biopotentials to monitor various vital signs on two volunteers. In this study, a new method to monitor lung function, such as respiration rate and tidal volume, is presented using the multi-sensor approach. Using the new sensor, we obtained lung sound, electrocardiogram (ECG), and electromyogram (EMG) measurements at the external intercostal muscles (EIM) and at the diaphragm during breathing cycles with 500 mL, 625 mL, 750 mL, 875 mL, and 1000 mL tidal volume. The tidal volumes were controlled with a spirometer. The duration of each breathing cycle was 8 s and was timed using a metronome. For each of the different tidal volumes, the EMG data was plotted against time and the area under the curve (AUC) was calculated. The AUC calculated from EMG data obtained at the diaphragm and EIM represent the expansion of the diaphragm and EIM respectively. AUC obtained from EMG data collected at the diaphragm had a lower variance between samples per tidal volume compared to those monitored at the EIM. Using cubic spline interpolation, we built a model for computing tidal volume from EMG data at the diaphragm. Our findings show that the new sensor can be used to measure respiration rate and variations thereof and holds potential to estimate tidal lung volume from EMG measurements obtained from the diaphragm.


Assuntos
Diafragma , Respiração , Volume de Ventilação Pulmonar , Dispositivos Eletrônicos Vestíveis , Acústica , Eletrocardiografia , Humanos , Sons Respiratórios