Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38795258

RESUMO

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Análise do Estresse Dentário , Análise de Elementos Finitos , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Zircônio , Cetonas/química , Polietilenoglicóis/química , Humanos , Zircônio/química , Titânio/química , Fibra de Carbono/química , Projeto do Implante Dentário-Pivô , Incisivo , Materiais Dentários/química , Implantes Dentários para Um Único Dente , Osso Cortical , Vidro/química , Planejamento de Prótese Dentária
2.
Clin Exp Dent Res ; 10(3): e856, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38818850

RESUMO

OBJECTIVES: This study aimed to compare the flexural strength of monolithic zirconia with different thicknesses and two sintering techniques. MATERIALS AND METHODS: This in vitro, experimental study was conducted on 28 monolithic zirconia discs with 10 mm diameter and 0.5 (n = 14) and 1.2 mm (n = 14) thickness. Each group was divided into two subgroups (n = 7) for fast (60 min) and conventional (120 min) sintering at 1450°C. After sintering, the specimens were thermocycled and their flexural strength was measured by piston-on-3-balls technique in a universal testing machine (0.5 mm/min, 1.2 mm pin diameter). Data were analyzed by the Weibull test, one-way analysis of variance, and Tukey's test (α = .05). RESULTS: The flexural strength of specimens with 1.2 mm thickness was significantly higher than that of specimens with 0.5 mm thickness (p < .05). The flexural strength of 1.2 mm/120-min group was slightly, but not significantly, higher than that of 1.2 mm/60-min group (p > .05). The flexural strength of 0.5 mm/120-min group was slightly, but not significantly, higher than that of 0.5 mm/60-min group (p > .05). CONCLUSION: The increase in thickness of monolithic zirconia increases its flexural strength; however, increasing the sintering time appears to have no significant effect on the flexural strength of monolithic zirconia.


Assuntos
Materiais Dentários , Resistência à Flexão , Teste de Materiais , Zircônio , Zircônio/química , Materiais Dentários/química , Análise do Estresse Dentário , Propriedades de Superfície , Temperatura Alta , Técnicas In Vitro
3.
Microsc Res Tech ; 87(8): 1955-1964, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38581370

RESUMO

To incorporate different concentrations of Al2O9Zr3 (1%, 5%, and 10%) nanoparticles (NP) into the ER adhesive and subsequently assess the impact of this addition on the degree of conversion, µTBS, and antimicrobial efficacy. The current research involved a wide-ranging examination that merged various investigative techniques, including the application of scanning electron microscopy (SEM) for surface characterization of NP coupled with energy-dispersive x-ray spectroscopy (EDX), Fourier-transform infrared (FTIR) spectroscopy, µTBS testing, and microbial analysis. Teeth were divided into four groups based on the application of modified and unmodified three-step ER adhesive primer. Group 1 (0% Al2O9Zr3 NPs) Control, Group 2 (1% Al2O9Zr3 NPs), Group 3 (5% Al2O9Zr3 NPs), and Group 4 (10% Al2O9Zr3 NPs). EDX analysis of Al2O9Zr3 NPs was performed showing elemental distribution in synthesized NPs. Zirconium (Zr), Aluminum (Al), and Oxides (O2). After primer application, an assessment of the survival rate of Streptococcus mutans was completed. The FTIR spectra were analyzed to observe the characteristic peaks indicating the conversion of double bonds, both before and after the curing process, for the adhesive Etch and rinse containing 1,5,10 wt% Al2O9Zr3 NPs. µTBS and failure mode assessment were performed using a Universal Testing Machine (UTM) and stereomicroscope respectively. The µTBS and S.mutans survival rates comparison among different groups was performed using one-way ANOVA and Tukey post hoc (p = .05). Group 4 (10 wt% Al2O9Zr3 NPs + ER adhesive) specimens exhibited the minimum survival of S.mutans (0.11 ± 0.02 CFU/mL). Nonetheless, Group 1 (0 wt% Al2O9Zr3 NPs + ER adhesive) displayed the maximum surviving S.mutans (0.52 ± 0.08 CFU/mL). Moreover, Group 2 (1 wt% Al2O9Zr3 NPs + ER adhesive) (21.22 ± 0.73 MPa) samples displayed highest µTBS. However, the bond strength was weakest in Group 1 (0 wt% Al2O9Zr3 NPs + ER adhesive) (14.13 ± 0.32 MPa) study samples. The etch-and-rinse adhesive exhibited enhanced antibacterial activity and micro-tensile bond strength (µTBS) when 1% Al2O9Zr3 NPs was incorporated, as opposed to the control group. Nevertheless, the incorporation of Al2O9Zr3 NPs led to a decrease in DC. RESEARCH HIGHLIGHTS: 10 wt% Al2O9Zr3 NPs + ER adhesive specimens exhibited the minimum survival of S.mutans. 1 wt% Al2O9Zr3 NPs + ER adhesive samples displayed the most strong composite/CAD bond. The highest DC was observed in Group 1: 0 wt% Al2O9Zr3 NPs + ER adhesive.


Assuntos
Alumínio , Antibacterianos , Dentina , Microscopia Eletrônica de Varredura , Streptococcus mutans , Resistência à Tração , Zircônio , Zircônio/química , Streptococcus mutans/efeitos dos fármacos , Alumínio/química , Alumínio/análise , Alumínio/farmacologia , Antibacterianos/farmacologia , Humanos , Dentina/química , Dentina/efeitos dos fármacos , Dentina/microbiologia , Cárie Dentária/microbiologia , Nanopartículas/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Cimentos Dentários/química , Cimentos Dentários/farmacologia , Espectrometria por Raios X/métodos , Colagem Dentária , Propriedades de Superfície , Adesivos/química
4.
Int J Implant Dent ; 10(1): 13, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38498247

RESUMO

PURPOSE: Despite the differences in material properties and shapes among the different types of prefabricated titanium (pTiA) and individualized hybrid zirconia abutments (ihZiA), the biological and clinical relevance of materials and construction features remains vague. Yet, individualized ihZiA are increasingly implemented into daily routine aiming to satisfy rising expectations. The objective was to compare these two types of abutments in fixed dental prostheses (FDP). METHODS: This cross-sectional study examined 462 implants in 102 patients comparing pTiA (52 patients) to ihZiA (50 patients) for FDP. These different treatment regimens were evaluated in terms of peri-implant health, radiographic bone loss, and oral-health related quality of life (OH-QoL) with special consideration of abutment type and superstructure design. RESULTS: ihZiA showed significantly different design features than prefabricated pTiA, but the annual bone loss in both groups did not. Visible titanium in the esthetic zone negatively impacted OHIP 14 scores. The combination of an emergence angle (EA) of < 30° and a concave emergence profile (EP) as well as gingiva thickness (p = 0.002) at the time of the prosthetic restoration significantly improved the annual peri-implant bone loss, independently of the abutment type. CONCLUSION: ihZiA showed comparable results to pTiA. To optimize the long-term outcome, not just material alone but generating adequate soft tissue thickness, minimizing the EA, and applying a concave EP seem to be the most relevant factors. To improve OH-QoL, particular attention must be paid to the esthetic zone.


Assuntos
Qualidade de Vida , Titânio , Humanos , Estudos Transversais , Titânio/química , Estética Dentária , Zircônio/química , Dente Suporte
5.
J Dent ; 144: 104942, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38494044

RESUMO

OBJECTIVES: This study endeavours to investigate the effect of printing orientation on the trueness of additively manufactured molar zirconia crowns. The areal surface roughness and the characteristics of the marginal regions of the crowns were also considered. METHODS: Twelve molar crowns were manufactured at 0°, 45°, and, 90° printing orientations in a Lithoz and AON zirconia printer, respectively. Twelve milled crowns were used as a comparison. Samples were scanned and analysed in metrology software to determine the trueness of the groups. Regions of interest were defined as the margins, intaglio surface and contact points. Areal surface roughness and print layer thickness were further analysed using a confocal laser scanning microscope. RESULTS: The results indicate that there are clear differences between the investigated desktop (AON) and industrial (Lithoz) 3D printer. The 45° Lithoz group is the only sample group showing no significantly different results in trueness for all regions analysed compared to the milled group. Areal surface roughness analysis indicates that the print layers in the marginal regions are within clinically tolerable limits and surface characteristics. CONCLUSIONS: The printing orientation for zirconia crowns is critical to trueness, and differences are evident between different AM apparatuses. Considerations for design and orientation between different apparatuses should therefore be considered when utilising direct additive manufacturing processes. The areal surface roughness of the marginal regions is within acceptable clinical limits for all manufacturing processes and print orientations considered. CLINICAL SIGNIFICANCE: The materials and apparatuses for additive manufacturing of zirconia crowns are now clinically acceptable from the perspective of the trueness of a final crown for critical functional surfaces and areal surface roughness of the marginal regions.


Assuntos
Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Impressão Tridimensional , Propriedades de Superfície , Zircônio , Zircônio/química , Humanos , Materiais Dentários/química , Microscopia Confocal , Dente Molar , Teste de Materiais , Adaptação Marginal Dentária
6.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37684141

RESUMO

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Assuntos
Cimentos Dentários , Implantes Dentários , Cimentos Dentários/química , Titânio/química , Coroas , Zircônio/química , Teste de Materiais , Dente Suporte , Análise do Estresse Dentário
7.
Dent Mater ; 39(7): 669-676, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37230861

RESUMO

OBJECTIVES: The aim of this study was to evaluate the mechanical properties and cost efficiency of direct ink writing (DIW) printing of two different zirconia inks compared to casting and subtractive manufacturing. METHODS: Zirconia disks were manufactured by DIW printing and the casting process and divided into six subgroups (n = 20) according to sintering temperatures (1350 °C, 1450 °C and 1550 °C) and two different ink compositions (Ink 1, Ink 2). A CAD/CAM-milled high strength zirconia (3Y-TZP) was added as reference group. The biaxial flexural strength (BFS) was measured using the piston-on-three-balls test. X-ray-diffraction (XRD) was used for microstructural analysis. The cost efficiency was compared for DIW printing and subtractive manufacturing by calculation of the manufacturing costs of one dental crown. RESULTS: Using XRD, monoclinic and tetragonal phases were detected for Ink 1, for all other groups no monoclinic phase was detected. The CAD/CAM-milled ceramic showed a significantly higher BFS than all other groups. The BFS of Ink 2 was significantly higher than the BFS of Ink 1. At a sintering temperature of 1550 °C the mean BFS of the printed Ink 2 was 822 ± 174 MPa. The BFS of the cast materials did not show a significantly higher BFS than the corresponding printed group for any tested parameter-set. The manufacturing costs of DIW printed crowns are lower than the manufacturing costs of CAD/CAM-milled crowns. CONCLUSION: DIW has a high potential to replace subtractive processes for dental applications, as it shows promising mechanical properties for appropriate ink compositions and facilitates a highly cost effective production.


Assuntos
Cerâmica , Tinta , Teste de Materiais , Propriedades de Superfície , Cerâmica/química , Zircônio/química , Desenho Assistido por Computador , Impressão Tridimensional , Materiais Dentários/química
8.
Environ Sci Pollut Res Int ; 29(37): 56684-56695, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35347616

RESUMO

Sunlight active blue emissive zirconium, nitrogen, and sulfur co-doped carbon dots (Zr-N-S-CDs) have been synthesized by microwave-induced pyrolysis for achieving efficient photocatalytic degradation of pollutant malachite green dye (MG) in water. Surface morphology studies using high-resolution transmission electron microscopy confirmed the formation of spherical-shaped CDs with an absorbance peak at 350 nm and emission peak at 437 nm in UV-vis and fluorescence spectroscopy, respectively. Surface functional groups, elemental composition, and metal/non-metal co-doping were confirmed by Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy. To understand the photocatalytic performance of Zr-N-S-CDs, various parameters, such as the source of energy, concentration of dye, catalyst dosage, and change in pH, were investigated. MG dye (20 ppm) at a pH 7 with 0.5 mg/mL of Zr-N-S-CDs could be photodegraded efficiently in 90 min under sunlight (99%) compared to dark and artificial light conditions. Moreover, real-time analysis of degradation rate could be conveniently calculated by integrating the colorimetric responses of MG dye with RGB values obtained by the "Color Picker" app of a smartphone. The degradation rate obtained using a smartphone (97.89%) was found to be in agreement with the UV-vis spectroscopy (99%), thus, providing a new, handy, and instrument-free route for speedy and quantitative estimation of the degradation of hazardous MG dye by Zr-N-S-CDs.


Assuntos
Carbono , Água , Carbono/química , Corantes , Nitrogênio/química , Espectroscopia Fotoeletrônica , Corantes de Rosanilina , Smartphone , Enxofre/química , Água/química , Zircônio/química
9.
ACS Appl Mater Interfaces ; 13(3): 3521-3527, 2021 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-33440931

RESUMO

Small-molecule impurities, such as N-nitrosodimethylamine (NDMA), have infiltrated the generic drug industry, leading to recalls in commonly prescribed blood pressure and stomach drugs in over 43 countries since 2018 and directly affecting tens of millions of patients. One promising strategy to remove small-molecule impurities like NDMA from drug molecules is by size exclusion, in which the contaminant is removed by selective adsorption onto a (micro)porous material due to its smaller size. However, current solution-phase size-exclusion separations are primarily limited by the throughput-selectivity trade-off. Here, we report a bioinspired solution to conquer these critical challenges by leveraging the assembly of atomically precise building blocks into hierarchically porous structures. We introduce a bottom-up approach to form micropores, mesopores, and macroscopic superstructures simultaneously using functionalized oxozirconium clusters as building blocks. Further, we leverage recent advances in photopolymerization to design macroscopic flow structures to mitigate backpressure. Based on these multiscale design principles, we engineer simple, inexpensive devices that are able to separate NDMA from contaminated drugs. Beyond this urgent model system, we expect this design strategy to open up hitherto unexplored avenues of nanomaterial superstructure fabrication for a range of size-exclusion purification strategies.


Assuntos
Dimetilnitrosamina/isolamento & purificação , Compostos Organometálicos/química , Zircônio/química , Adsorção , Contaminação de Medicamentos , Extração Líquido-Líquido , Modelos Moleculares , Porosidade
10.
J. oral res. (Impresa) ; 8(4): 298-304, nov. 5, 2019. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-1145351

RESUMO

Objective: the purpose of this multicenter retrospective study was to report on survival, success, and complication rates in monolithic zirconia restorations on teeth and implants. Materials and Methods: data on 671 monolithic zirconia restorations was collected by five prosthodontists from three different specialty practice centers, including a dental school and two private practice centers. Restorations included single crowns and multiple-unit fixed dental prostheses on teeth and implants in the posterior area (premolar and molars). Follow-up time was up to 62 months. Results: mean follow-up time was 28.1±12.9 months. A total of 671 units, 534 single crowns, and 137 multi-unit restorations. Cumulative survival and success rates at 5 years were 97.4%, and 93.8% respectively. Complications presented in 11 restorations out of 671 and included: decementation, abutment screw loosening, restoration crack, restoration fracture, and tooth fracture. No significant differences were observed between tooth-supported and implant-supported restoration (p=0.42), single crowns and multiple-unit restorations (p=0.07), bruxers and non-bruxers (p=0.57). Patients with group function occlusal scheme had significantly less survival rates (p=0.001). Conclusion: the use of monolithic zirconia for restorations on the posterior teeth and implants seems to be promising as it provides a durable solution with a low rate of complications.


Objetivo: el propósito de este estudio retrospectivo multicéntrico fue informar sobre las tasas de supervivencia, éxito y complicaciones en restauraciones monolíticas de circonio en dientes e implantes. Materiales y Métodos: cinco prostodoncistas recolectaron datos de 671 restauraciones monolíticas de zirconia de tres centros de práctica especializados: una escuela de odontología y dos centros de práctica privados. Las restauraciones incluyeron coronas individuales y prótesis dentales fijas de unidades múltiples en dientes e implantes en el área posterior (premolares y molares). El tiempo de seguimiento fue de hasta 62 meses. Resultados: el tiempo medio de seguimiento fue de 28,1±12,9 meses. Un total de 671 unidades, 534 coronas individuales y 137 restauraciones de unidades múltiples. La supervivencia acumulada y las tasas de éxito a los 5 años fueron del 97,4% y del 93,8%, respectivamente. Las complicaciones se presentaron en 11 restauraciones de 671 e incluyeron: fracaso del cementado, aflojamiento del tornillo del pilar, grieta en la restauración, fractura de restauración y fractura de dientes. No se observaron diferencias significativas entre la restauración con soporte dental y con implante (p=0,42), coronas individuales y restauraciones de unidades múltiples (p=0,07), pacientes con bruxismo y sin bruxismo (p=0,57). Los pacientes con esquema oclusal de función grupal tuvieron tasas de supervivencia significativamente menores (p= 0,0 01). Conclusión: el uso de zirconia monolítica para restauraciones en los dientes posteriores y en implantes parece ser prometedor, ya que proporciona una solución duradera con una baja tasa de complicaciones.


Assuntos
Humanos , Zircônio/química , Implantes Dentários para Um Único Dente , Implantação Dentária Endóssea , Fraturas dos Dentes , Estudos Retrospectivos , Resultado do Tratamento , Retenção em Prótese Dentária/estatística & dados numéricos , Coroas , Cimentos Dentários
11.
Clin Cancer Res ; 25(23): 7014-7023, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31540979

RESUMO

PURPOSE: In patients with cancer who have an abnormal biomarker finding, the source of the biomarker in the bloodstream must be located for confirmation of diagnosis, staging, and therapy planning. We evaluated if immuno-PET with the radiolabeled high-affinity antibody HuMab-5B1 (MVT-2163), binding to the cancer antigen CA19-9, can identify the source of elevated biomarkers in patients with pancreatic cancer. PATIENTS AND METHODS: In this phase I dose-escalating study, 12 patients with CA19-9-positive metastatic malignancies were injected with MVT-2163. Within 7 days, all patients underwent a total of four whole-body PET/CT scans. A diagnostic CT scan was performed prior to injection of MVT-2163 to correlate findings on MVT-2163 PET/CT. RESULTS: Immuno-PET with MVT-2163 was safe and visualized known primary tumors and metastases with high contrast. In addition, radiotracer uptake was not only observed in metastases known from conventional CT, but also seen in subcentimeter lymph nodes located in typical metastatic sites of pancreatic cancer, which were not abnormal on routine clinical imaging studies. A significant fraction of the patients demonstrated very high and, over time, increased uptake of MVT-2163 in tumor tissue, suggesting that HuMab-5B1 labeled with beta-emitting radioisotopes may have the potential to deliver therapeutic doses of radiation to cancer cells. CONCLUSIONS: Our study shows that the tumor antigen CA19-9 secreted to the circulation can be used for sensitive detection of primary tumors and metastatic disease by immuno-PET. This significantly broadens the number of molecular targets that can be used for PET imaging and offers new opportunities for noninvasive characterization of tumors in patients.


Assuntos
Adenocarcinoma/secundário , Anticorpos Monoclonais Humanizados/farmacocinética , Biomarcadores Tumorais/sangue , Antígeno CA-19-9/imunologia , Neoplasias Pancreáticas/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/farmacocinética , Adenocarcinoma/sangue , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/imunologia , Idoso , Anticorpos Monoclonais Humanizados/administração & dosagem , Biomarcadores Tumorais/imunologia , Antígeno CA-19-9/sangue , Antígeno CA-19-9/química , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/sangue , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/imunologia , Prognóstico , Compostos Radiofarmacêuticos/administração & dosagem , Distribuição Tecidual , Zircônio/química
12.
Sensors (Basel) ; 19(9)2019 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-31060259

RESUMO

A new breed of nanocomposite-based spray-on sensor is developed for in-situ active structural health monitoring (SHM). The novel nanocomposite sensor is rigorously designed with graphene as the nanofiller and polyvinylpyrrolidone (PVP) as the matrix, fabricated using a simple spray deposition process. Electrical analysis, as well as morphological characterization of the spray-on sensor, was conducted to investigate percolation characteristic, in which the optimal threshold (~0.91%) of the graphene/PVP sensor was determined. Owing to the uniform and stable conductive network formed by well-dispersed graphene nanosheets in the PVP matrix, the tailor-made spray-on sensor exhibited excellent piezoresistive performance. By virtue of the tunneling effect of the conductive network, the sensor was proven to be capable of perceiving signals of guided ultrasonic waves (GUWs) with ultrahigh frequency up to 500 kHz. Lightweight and flexible, the spray-on nanocomposite sensor demonstrated superior sensitivity, high fidelity, and high signal-to-noise ratio under dynamic strain with ultralow magnitude (of the order of micro-strain) that is comparable with commercial lead zirconate titanate (PZT) wafers. The sensors were further networked to perform damage characterization, and the results indicate significant application potential of the spray-on nanocomposite-based sensor for in-situ active GUW-based SHM.


Assuntos
Técnicas Biossensoriais , Grafite/química , Monitorização Fisiológica/instrumentação , Nanocompostos/química , Humanos , Chumbo/química , Povidona/química , Titânio/química , Ondas Ultrassônicas , Zircônio/química
13.
Radiat Res ; 191(5): 466-474, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30896281

RESUMO

In this study, the behavior dynamics of Zirconium-89 (89Zr)-labeled monoclonal antibodies (MAbs) after injection into the human body were modeled. This modified biokinetic model can be used for dose assessment, not only for 89Zr-labeled MAb tumor visualization, but also for diagnostic and therapeutic radiation with MAb labeled with other radionuclides. A modified biokinetic model was created based on experimental data from previously published studies. Cumulative 89Zr activity in organs and tissues per Bq of administered activity was calculated using the WinAct program. For most organs receiving the highest radiation dose, average absorbed doses were estimated using IDAC version 2.1 software. The results from the modeled calculations were compared with recently published results from studies of real patients. The calculations revealed that organs with the highest dose were the spleen, liver, kidneys and red bone marrow, at 1.54, 1.33, 0.81 and 0.82 mGy/MBq, respectively. In the modified biokinetic model, with MAb injection, organs exhibiting the highest dose were liver, heart wall, spleen, red bone marrow and pancreas, at 1.05, 0.93, 0.79, 0.69 and 0.67 mGy/MBq, respectively.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/farmacocinética , Radioisótopos/química , Zircônio/química , Anticorpos Monoclonais/administração & dosagem , Humanos , Injeções , Marcação por Isótopo , Cinética , Modelos Biológicos , Radiometria , Distribuição Tecidual
14.
Environ Sci Pollut Res Int ; 26(4): 3501-3516, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30519911

RESUMO

Three different types of zirconium-modified bentonites (ZrMBs) including zirconium-modified original bentonite (ZrMOB), zirconium-modified magnesium-pretreated bentonite (ZrMMgB), and zirconium-modified calcium-pretreated bentonite (ZrMCaB) were synthesized and used as active covering materials to suppress the release of phosphorus (P) from sediments. To assess the covering efficiency of ZrMBs to inhibit P release from sediments, we examined the impact of ZrMB covering layer on P mobilization in sediments at different depths as well as the release of P through the interface between sediment and overlying water (SWI) by use of simulating P release control experiments and diffusive gradients in thin films (DGT) technology. The results showed that the amount of soluble reactive P (SRP) in the overlying water greatly decreased after covering with ZrMBs. Moreover, both pore water SRP and DGT-liable P (DGT-P) in the top sediments decreased after capping with ZrMBs. An obvious stratification of DGT-P was observed along the vertical direction after covering with ZrMBs, and static and active layers were found in the top sediment and in the lower sediment directly below the static layer, respectively. Furthermore, ZrMB covering led to the change of P species from easily released P to relatively or very stable P, making P in the top sediment more stable compared to that without ZrMB covering. Besides, an overwhelming majority of P immobilized by ZrMBs is hard to be re-released into the water column in a common environment. Overall, the above results demonstrate that sediment covering with ZrMBs could effectively prevent the transport of SRP from sediments into the overlying water through the SWI, and the control of P transport into the overlying water by ZrMB covering could be mostly due to the immobilization of pore water SRP, DGT-P, and mobile P in the top sediment by ZrMBs.


Assuntos
Bentonita/química , Sedimentos Geológicos/química , Fósforo/química , Poluentes do Solo/química , Poluentes Químicos da Água/química , Poluição Química da Água/prevenção & controle , Zircônio/química
15.
Colloids Surf B Biointerfaces ; 173: 109-120, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30273871

RESUMO

Biologically safe Ti-based quaternary Ti-Nb-Zr-Si thin film metallic glass (TFMG) was fabricated by sputtering on Titanium alloy (Ti6Al4V or Ti alloy) substrates. A preliminary assessment regarding glass forming ability, thermal stability and corrosion behavior was performed. The amorphous nature of the film is evidenced from the X-ray Diffraction (XRD) and Transmission Electron Microscope (TEM) and Selected Area Electron Diffraction (SAED) patterns. Ion scattering spectroscopy (ISS) and X-ray Photoelectron Spectroscopy (XPS) were used to analyse the chemical composition of surface which indicated oxygen on the top surface of the film and confirms the presence of Ti, Nb, Si, Zr without any other impurities. The surface morphology of the film showed a smooth surface as observed from scanning electron microscope (SEM) and atomic force microscope (AFM) analysis. It is found that the TFMG can sustain in the body-fluid, exhibiting superior corrosion resistance and electrochemical stability than the bare titanium. The cytotoxicity studies with L929 fibroblast cells showed that coatings were graded as zero and non-cytotoxic in nature. No hemolysis was observed on the coated surface indicating a better hemocompatibility. Assay using SaOS-2 bone cells showed good growth on the coated surfaces. The calcium assay showed that the SaOS-2 cells grown and differentiated on the control (Tissue Culture Polystyrene) TCPS surface had the highest mineral level. Higher alkaline phosphatase activity is obtained in SaOS-2 osteoblast cell cultures on TFMG than the control.


Assuntos
Ligas/farmacologia , Diferenciação Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Osteoblastos/efeitos dos fármacos , Alicerces Teciduais , Fosfatase Alcalina/metabolismo , Ligas/química , Animais , Biomarcadores/metabolismo , Linhagem Celular , Linhagem Celular Tumoral , Materiais Revestidos Biocompatíveis/química , Eritrócitos/efeitos dos fármacos , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Humanos , Camundongos , Nióbio/química , Nióbio/farmacologia , Osteoblastos/citologia , Osteoblastos/metabolismo , Silício/química , Silício/farmacologia , Propriedades de Superfície , Titânio/química , Titânio/farmacologia , Zircônio/química , Zircônio/farmacologia
16.
Bioconjug Chem ; 29(10): 3476-3482, 2018 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-30227708

RESUMO

The swell of experimental imaging technologies to noninvasively measure immune checkpoint protein expression presents the opportunity for rigorous comparative studies toward identifying a gold standard. 89Zr-atezolizumab is currently in man, and early data show tumor targeting but also abundant uptake in several normal tissues. Therefore, we conducted a reverse translational study both to understand if tumor to normal tissue ratios for 89Zr-atezolizumab could be improved and to make direct comparisons to 89Zr-C4, a radiotracer that we showed can detect a large dynamic range of tumor-associated PD-L1 expression. PET/CT and biodistribution studies in tumor bearing immunocompetent and nu/nu mice revealed that high specific activity 89Zr-atezolizumab (∼2 µCi/µg) binds to PD-L1 on tumors but also results in very high uptake in many normal mouse tissues, as expected. Unexpectedly, 89Zr-atezolizumab uptake was generally higher in normal mouse tissues compared to 89Zr-C4 and lower in H1975, a tumor model with modest PD-L1 expression. Also unexpectedly, reducing the specific activity at least 15-fold suppressed 89Zr-atezo uptake in normal mouse tissues but increased tumor uptake to levels observed with high specific activity 89Zr-C4. In summary, these data reveal that low specific activity 89Zr-atezo may be necessary for accurately measuring PD-L1 in the tumor microenvironment, assuming a threshold can be identified that preferentially suppresses binding in normal tissues without reducing binding to tumors with abundant expression. Alternatively, high specific activity approaches like 89Zr-C4 PET may be simpler to implement clinically to measure the broad dynamic range of PD-L1 expression known to manifest among tumors.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Antineoplásicos/uso terapêutico , Compostos Radiofarmacêuticos/química , Zircônio/química , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/farmacocinética , Anticorpos Monoclonais Humanizados , Antineoplásicos/química , Antineoplásicos/farmacocinética , Linhagem Celular Tumoral , Portadores de Fármacos , Composição de Medicamentos , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Camundongos , Camundongos Nus , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Tecidual
17.
Ecotoxicol Environ Saf ; 159: 301-309, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-29772462

RESUMO

The photodegradation and phytotoxicity of the pharmaceutical antibiotic, sulphamethoxazole (SMX) and the azo-dye reactive-red-194 (RR194) under visible-light irradiation of TiO2 nanoparticles modified by silver and zirconium was investigated. The results indicated that sulphamethoxazole and its toxic degradation by product, 3-amino-5-methylisoxazole and RR-194 could be degraded efficiently by the co-doped Zr/Ag-TiO2 catalyst. PL studies and ROS generation results suggested that the effective charge separation was carried out while irradiation of the modified TiO2 nanoparticles. Phytotoxicity tests demonstrated lower percentage of germination in P. vulgaris (40%), V. radiata (30%) and P. lunatus (30%) of the seeds treated with 50 ppm of SMX, compared to the seeds treated with the degradation products (100%). The results with 50 ppm of RR-194 also showed lower percentage of germination in P. vulgaris (40%), V. radiata (50%) and P. lunatus (30%) compared to the degradation products (100%). Furthermore, significant increase in root and shoot development was observed in the seeds treated with the degraded products when compared with SMX and RR-194. Overall, this study contributes to further understanding the photodegradation mechanisms, degradation products and environmental fate of SMX and RR-194 in water which helps in the evaluation and mitigation of the environmental risk of SMX and RR-194 for water reuse and crop irrigation.


Assuntos
Antibacterianos/química , Corantes/química , Germinação/efeitos dos fármacos , Nanopartículas Metálicas/química , Sulfametoxazol/química , Poluentes Químicos da Água/química , Antibacterianos/metabolismo , Antibacterianos/toxicidade , Catálise , Corantes/metabolismo , Corantes/toxicidade , Isoxazóis/química , Isoxazóis/metabolismo , Isoxazóis/toxicidade , Cinética , Luz , Processos Fotoquímicos , Fotólise , Prata/química , Sulfametoxazol/metabolismo , Sulfametoxazol/toxicidade , Titânio/química , Poluentes Químicos da Água/metabolismo , Poluentes Químicos da Água/toxicidade , Zircônio/química
18.
J Biomed Mater Res B Appl Biomater ; 106(2): 834-842, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28390183

RESUMO

Ti-based alloys have increased importance for biomedical applications due to their excellent properties. In particular, the two recently developed TiZrPdSi(Nb) alloys, with a predominant ß-Ti phase microstructure, have good mechanical properties, such as a relatively low Young's modulus and high hardness. In the present work, the cytocompatibility of these alloys was assessed using human osteoblast-like Saos-2 cells. Cells grown on the alloys showed larger spreading areas (more than twice) and higher vinculin content (nearly 40% increment) when compared with cells grown on glass control surfaces, indicating a better cell adhesion. Moreover, cell proliferation was 18% higher for cells growing on both alloys than for cells growing on glass and polystyrene control surfaces. Osteogenic differentiation was evaluated by quantifying the expression of four osteogenic genes (osteonectin, osteocalcin, osteopontin, and bone sialoprotein), the presence of three osteogenic proteins (alkaline phosphatase, collagen I, and osteocalcin) and the activity of alkaline phosphatase at different time-points. The results demonstrated that TiZrPdSi and TiZrPdSiNb alloys enhance osteoblast differentiation, and that cells grown on TiZrPdSiNb alloy present higher levels of some late osteogenic markers during the first week in culture. These results suggest that the TiZrPdSi(Nb) alloys can be considered as excellent candidates for orthopaedical uses. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 834-842, 2018.


Assuntos
Ligas , Diferenciação Celular/efeitos dos fármacos , Módulo de Elasticidade , Teste de Materiais , Osteoblastos/metabolismo , Osteogênese/efeitos dos fármacos , Ligas/química , Ligas/farmacologia , Linhagem Celular , Humanos , Nióbio/química , Nióbio/farmacologia , Osteoblastos/citologia , Paládio/química , Paládio/farmacologia , Silicones/química , Silicones/farmacologia , Titânio/química , Titânio/farmacologia , Zircônio/química , Zircônio/farmacologia
19.
Adv Clin Exp Med ; 26(5): 803-809, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29068576

RESUMO

BACKGROUND: The implant primary stability is a fundamental prerequisite for a success of osseointegration process which determines the prosthetic reconstruction time. OBJECTIVES: The aim of the present study was to assess the quality and precision of modern conical bone computer tomography (CBCT) software in preparing root analog zirconia implants (RAZIs) by measuring its primary stability by means of the Periotest device. MATERIAL AND METHODS: Thirteen pig jaws with proper erupted first premolar (P1) teeth were used in the study. The CBCT examination was conducted in the area of the P1 tooth in each mandible. The 3-dimensional (3D) view of each tooth was designed from CBCT scan. The created 3D images were used to prepare root analog zirconia implants milled from a medical-grade zirconia block by means of laboratory milling. The RAZIs and titanium implants were placed into an alveolar socket after the tooth had been removed. The primary stability of the teeth before their extraction (G1), RAZIs (G2) and titanium implants (G3) were checked by Periotest devices. RESULTS: The mean results in PTV were: 15.9, 3.35, 12.7 for G1, G2 and G3 group, respectively. RAZIs during immediate loading achieved a significantly higher primary stability (lower Periotest value) as compared to the teeth and implants. CONCLUSIONS: The modern CBCT device allows us to design a precise image of an extracted tooth for the purpose of manufacturing a root analog implant. The additional feature of the surgical protocol using RAZI is the possibility of avoiding the augmentation procedure, which reduces the whole cost of the treatment.


Assuntos
Dente Pré-Molar/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Implantes Dentários , Mandíbula/cirurgia , Osseointegração , Radiografia Dentária/métodos , Software , Raiz Dentária/cirurgia , Zircônio/química , Animais , Dente Pré-Molar/diagnóstico por imagem , Planejamento de Prótese Dentária , Mandíbula/diagnóstico por imagem , Teste de Materiais , Modelos Animais , Falha de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Sus scrofa , Extração Dentária , Raiz Dentária/diagnóstico por imagem
20.
ChemMedChem ; 12(18): 1555-1571, 2017 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-28715615

RESUMO

Zirconium-89 is a positron-emitting radionuclide of high interest for medical imaging applications with positron emission tomography (PET). For the introduction of this radiometal into biologically active targeting vectors, the chelating agent desferrioxamine B (DFO) is commonly applied. However, DFO is known to form 89 Zr complexes of limited in vivo stability. Herein we describe the rational design and chemical development of a new macrocyclic four-hydroxamate-bearing chelating agent-1,10,19,28-tetrahydroxy-1,5,10,14,19,23,28,32-octaazacyclohexatriacontan-2,6,11,15,20,24,29,33-octaone (CTH36)-for the stable complexation of Zr4+ . For this purpose, we first performed computational studies to determine the optimal chelator geometry before we developed different synthesis pathways toward the target structures. The best results were obtained using an efficient solution-phase-based synthesis strategy toward the target chelating agent. To enable efficient and chemoselective conjugation to biomolecules, a tetrazine-modified variant of CTH36 was also developed. The excellent conjugation characteristics of the so-functionalized chelator were demonstrated on the example of the model peptide TCO-c(RGDfK). We determined the optimal 89 Zr radiolabeling parameters for CTH36 as well as its bioconjugate, and found that 89 Zr radiolabeling proceeds efficiently under very mild reaction conditions. Finally, we performed comparative complex stability tests for 89 Zr-CHT36-c(RGDfK) and 89 Zr-DFO-c(RGDfK), showing improved complex stability for the newly developed chelator CTH36.


Assuntos
Quelantes/química , Complexos de Coordenação/química , Desenho de Fármacos , Ácidos Hidroxâmicos/química , Zircônio/química , Complexos de Coordenação/síntese química , Marcação por Isótopo , Espectroscopia de Ressonância Magnética , Peptídeos Cíclicos/síntese química , Peptídeos Cíclicos/química , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA