Your browser doesn't support javascript.
loading
Determinar la precisión diagnóstica de la ecografía tridimensional en casos de fístula perianal en comparación con los hallazgos intraoperatorios durante el procedimiento quirúrgico / Assessment of accuracy of three dimensional endo-anal ultrasound in diagnosis of perianal fistula in comparison to operative findings
Al-Qanbar, Maytham H; Shaaban, Ahmad A.
Afiliação
  • Al-Qanbar, Maytham H; University of Kufa. College of Medicine. Kufa. IQ
  • Shaaban, Ahmad A; AlSadr medical city. Najaf. IQ
Prensa méd. argent ; 106(2): 91-95, 20200000. tab
Artigo em Inglês | LILACS, BINACIS | ID: biblio-1369331
Biblioteca responsável: AR392.1
ABSTRACT

Aim:

To determine the diagnostic accuracy of three dimensional ultrasound in cases of perianal fistula compared to intra-operative findings during surgical procedure.

Background:

Perianal fistulae can be either low type (simple) or high type (complex) and surgical treatment options differ accordingly. Preoperative three-dimensional endoanal ultrasonography (3D-EAUS) is a promising diagnostic technique that can effectively assist in choosing the most suitable treatment option for patients with anal fistula by providing the surgeon with accurate outlining of the fistula.

Methods:

The study is a cross sectional comparative study conducted at Al-Sadr Medical City during the period from September 2018 through September 2019, and included cases with fistula in ano, which were subjected to 3-D ultrasound, then followed up during surgery to obtain the intra-operative findings of the fistula.

Results:

The study included (78) patients whom their age ranged from (18-65) years. Majority of cases were males (79.49%). For assessing the concordance between 3D-EAUS and the intraoperative findings the Kappa coefficient for the internal opening was 0.9825 (P-value < 0.001), for the external opening was 0.9853 (P-value < 0.00), For the course of primary tract, Kappa = 0.9754 (P-value < 0.001) and for the course of the extension tract was 0.9761 with a P-value of < 0.001.

Conclusions:

Three-dimensional endoanal ultrasound is an effective and dependable tool for delineation the course of a perianal fistula.
Assuntos

Texto completo: Disponível Temas: ECOS / Aspectos gerais Bases de dados: LILACS Assunto principal: Estudos Transversais / Ultrassonografia / Fístula Retal / Técnicas e Procedimentos Diagnósticos / Imageamento Tridimensional / Período Intraoperatório Tipo de estudo: Estudo diagnóstico / Estudo de avaliação / Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Adulto / Humanos Idioma: Inglês Revista: Prensa méd. argent Assunto da revista: Medicina Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Iraque

Similares

MEDLINE

...
LILACS

LIS

Texto completo: Disponível Temas: ECOS / Aspectos gerais Bases de dados: LILACS Assunto principal: Estudos Transversais / Ultrassonografia / Fístula Retal / Técnicas e Procedimentos Diagnósticos / Imageamento Tridimensional / Período Intraoperatório Tipo de estudo: Estudo diagnóstico / Estudo de avaliação / Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Adulto / Humanos Idioma: Inglês Revista: Prensa méd. argent Assunto da revista: Medicina Ano de publicação: 2020 Tipo de documento: Artigo País de afiliação: Iraque