Your browser doesn't support javascript.
loading
Estimation of free-living energy expenditure using a novel activity monitor designed to minimize obtrusiveness.
Bonomi, Alberto G; Plasqui, Guy; Goris, Annelies H C; Westerterp, Klass R.
Afiliação
  • Bonomi AG; Department of Human Biology, Maastricht University, Maastricht, The Netherlands. a.bonomi@HB.unimaas.nl
Obesity (Silver Spring) ; 18(9): 1845-51, 2010 Sep.
Article em En | MEDLINE | ID: mdl-20186133
ABSTRACT
The aim of this study was to investigate the ability of a novel activity monitor designed to be minimally obtrusive in predicting free-living energy expenditure. Subjects were 18 men and 12 women (age 41 +/- 11 years, BMI 24.4 +/- 3 kg/m(2)). The habitual physical activity was monitored for 14 days using a DirectLife triaxial accelerometer for movement registration (Tracmor(D)) (Philips New Wellness Solutions, Lifestyle Incubator, the Netherlands). Tracmor(D) output was expressed as activity counts per day (Cnts/d). Simultaneously, total energy expenditure (TEE) was measured in free living conditions using doubly labeled water (DLW). Activity energy expenditure (AEE) and the physical activity level (PAL) were determined from TEE and sleeping metabolic rate (SMR). A multiple-linear regression model predicted 76% of the variance in TEE, using as independent variables SMR (partial-r(2) = 0.55, P < 0.001), and Cnts/d (partial r(2) = 0.21, P < 0.001). The s.e. of TEE estimates was 0.9 MJ/day or 7.4% of the average TEE. A model based on body mass (partial-r(2) = 0.31, P < 0.001) and Cnts/d (partial-r(2) = 0.23, P < 0.001) predicted 54% of the variance in TEE. Cnts/d were significantly and positively associated with AEE (r = 0.54, P < 0.01), PAL (r = 0.68, P < 0.001), and AEE corrected by body mass (r = 0.71, P < 0.001). This study showed that the Tracmor(D) is a highly accurate instrument for predicting free-living energy expenditure. The miniaturized design did not harm the ability of the instrument in measuring physical activity and in determining outcome parameters of physical activity such as TEE, AEE, and PAL.
Assuntos

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Monitorização Ambulatorial / Metabolismo Energético / Atividade Motora Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Obesity (Silver Spring) Assunto da revista: CIENCIAS DA NUTRICAO / FISIOLOGIA / METABOLISMO Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Temas: ECOS / Financiamentos_gastos Bases de dados: MEDLINE Assunto principal: Monitorização Ambulatorial / Metabolismo Energético / Atividade Motora Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Obesity (Silver Spring) Assunto da revista: CIENCIAS DA NUTRICAO / FISIOLOGIA / METABOLISMO Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Holanda