Your browser doesn't support javascript.
loading
Invasive assessment of doubtful aortic stenosis by measuring simultaneous transaortic gradient with a pressure wire.
Chopard, Romain; Meneveau, Nicolas; Plastaras, Philoktimon; Janin, Sebastien; Seronde, Marie-France; Ecarnot, Fiona; Schiele, Francois.
Afiliação
  • Chopard R; Department of Cardiology, University Hospital Jean Minjoz, University of Franche-Comte, EA 3920, Besançon, France. rchopard@chu-besancon.fr
Am J Cardiol ; 111(12): 1772-7, 2013 Jun 15.
Article em En | MEDLINE | ID: mdl-23540549
Two-dimensional transthoracic echocardiography (2D-TTE) is the reference technique for evaluating aortic stenosis (AS) but may be unreliable in some cases. We aimed to assess whether the use of a pressure wire to measure simultaneous transaortic gradient and aortic valve area (AVA) could be helpful in patients in whom initial noninvasive evaluations were considered doubtful for AS. Fifty-seven patients (mean age 76 years; 39 men) underwent cardiac catheterization with single arterial access for assessment of AVA with the Gorlin and Gorlin formula. Transaortic pressure was obtained by 2 invasive methods: (1) conventional pullback method (PM) from the left ventricle toward the aorta and (2) simultaneous method (SM) with transaortic pressure simultaneously recorded with a 0.014-inch pressure wire introduced into the left ventricle and with a diagnostic catheter placed in the ascending aorta. Reasons for inaccurate assessment by 2D-TTE were low flow states (88%) and/or atrial fibrillation (79%). Agreement for severe AS defined by AVA <0.6 cm²/m² between SM and 2D-TTE and between SM and PM was fair, with kappa coefficients of 0.38 (95% confidence interval [CI] 0.14-0.75) and 0.36 (95% CI 0.22-0.7) respectively; agreement was poor between 2D-TTE and PM (kappa: 0.23; 95% CI 0.002-0.36). SM led to a reclassification of the severity of AS in 9 patients (15.8%) compared with 2D-TTE and in 11 patients (19.3%) compared with PM. In conclusion, invasive evaluation of doubtful AS by measuring simultaneous transaortic gradient using a pressure wire may provide an attractive method that can lead to a change in therapeutic strategy in a substantial proportion of patients.
Assuntos

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Volume Sistólico / Transdutores de Pressão Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Volume Sistólico / Transdutores de Pressão Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Cardiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: França