Micro-method for the determination of glutathione in human blood.
Giustarini, Daniela; Fanti, Paolo; Matteucci, Elena; Rossi, Ranieri.
Afiliação
  • Giustarini D; Department of Life Sciences, Laboratory of Pharmacology and Toxicology, University of Siena, Via A. Moro 4, 53100 Siena, Italy. Electronic address: giustarini@unisi.it.
  • Fanti P; Division of Nephrology, Department of Medicine, The University of Texas Health Science Center San Antonio, San Antonio, TX 78229, USA; Audie L. Murphy VA Hospital, San Antonio, TX 78229, USA.
  • Matteucci E; Department of Clinical and Experimental Medicine, University of Pisa, Via Roma 67, 56126 Pisa, Italy.
  • Rossi R; Department of Life Sciences, Laboratory of Pharmacology and Toxicology, University of Siena, Via A. Moro 4, 53100 Siena, Italy.
Article em En | MEDLINE | ID: mdl-24636839
ABSTRACT
A new procedure is described for the visible-range spectrophotometric analysis of glutathione (GSH) in microvolumes of blood (as low as 0.5 µL) collected by fingerstick. Samples are diluted 1 to 300 (v/v) in a stabilizing solution, followed by determination of haemoglobin concentration and by acid deproteination. GSH is then measured in the clear supernatant by colorimetry using DTNB, i.e., 5,5'-dithio-bis(2-nitrobenzoic acid), in aqueous solution at pH 7.8. The DTNB reagent is prepared and kept at pH 6.2 until just prior its addition, thus avoiding spontaneous decomposition of the reagent. The assay is rapid, easy to adapt to large-scale studies and it avoids artefactual oxidation of GSH, a common methodological shortcoming. The method is precise with 1.7 to 3.4% intra-day relative standard deviation (RSD) and 2.2 to 4.2% inter-day RSD, and accurate with -1.4% to 2.3% intra-day relative error (RE) and -2.8% to 1.6% inter-day RE. GSH is recovered by 97.5 to 100% at all tested concentrations. The new colorimetric micro-method was validated by a reliable previously reported HPLC method. The procedure is suitable for minimally invasive investigation of oxidative stress in peripheral blood.
Assuntos
Palavras-chave

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Espectrofotometria / Glutationa Limite: Adult / Female / Humans / Male Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Temas: ECOS / Aspectos_gerais Bases de dados: MEDLINE Assunto principal: Espectrofotometria / Glutationa Limite: Adult / Female / Humans / Male Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2014 Tipo de documento: Article